Loading...
FW-19-1910Permit NO.: FW-08-19-1910 Miami Shores Village II Permit type: Fenced li 10050 NE 2 Ave Miami Shores FL 33138 Uuj%Work Clossificeatiow Ornamerital/Meth 305-795-2204 Permit Status: Approved Issue Date: 09/06/2019 Expiration:03/04/2020 Location Address Parcel Number 126 NE 103RD ST, Miami Shores, FL 33138 1132060131760 Contacts MAXI RAYMOND Owner HOME OWNER Contractor 126 NE 103 ST, MIAMI SHORES, FL 331382329 HOME OWNER Other:3057591170 Description: METAL FENCE DURA METAL PANEL 6 FT Valuation: $ 1,500.00 Inspection Requests: 3QS-762 49 Total Sq Feet: 0.00 Fees Application Fee - Other CCF DBPR Fee DCA Fee Education Surcharge Notary Fee Planning and Zoning Review Fee Scanning Fee Technology Fee Wire and Wood Fence Fee Total Amount $50.00 $1.20 $2.00 $2.00 $0.40 $5.00 $35.00 $9.00 $3.25 $80.00 $187.85 Payments Date Paid Amt Paid Total Fees $187.85 Credit Card 08/19/2019 $50.00 Credit Card 09/06/2019 $137.85 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulati,pgAonstruction, nc oning. Futhermore, I authorize the above named contractor to do the work stated. Signatuft Owner / Applicant / Contractor / Agent Date September 06, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION 4BUILDING ❑ ELECTRIC ❑ ROOFING - I VE[) FBC 20[l b Master Permit No. CN" cl�7 -� t 'I� I Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP %�d /� / /� CONTRACTOR ;�l , DRAWINGS JOB ADDRESS: 1', _ T AX L 03' ,7'r h4 LCU1� d'44 0&j4'2 3 1 X 2 City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: _Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): azi 1��9 n�� Phone#:,3/1���y Address: /cz6 Nz51Q3 p City: �%� .�i� ��S State: /L-� Zip: 3.313 [5 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: IJVV�Phone#: Address: City: State: Zip: Qualifier Name: State Certification or Registration #: DESIGNER: Architect/Engineer: one#: Certificate of Competency #: one#: Address: City: State: Zip: Value of Work for this Permit: $00 rim Footage of Work: ��Q Type of Work: ❑ Addition ❑ /Alteration LaJ New ❑l Reppaiir//Repla�cee� "" " ❑ Demolition Description of Work: �/ t�/LL �� DU" Ife-/'"[liyr p_ 4 irk' Specify color of color thru tile: Submittal Fee $ Permit Fee $ �11 CCF $ " CO/CC $ Scanning Fee $ 9.06 Radon Fee $ 0 DB••P((R $ 0 Notary $ 5• o® Technology Fee $ S Training/Education Fee $ 0. "F� Double Fee $ Structural Reviews $ 0 Bond $ 2 "PI Q A n In c� _ 5 TOTAL FEE NOW DUE $ 131. (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature i'Z Signature OWNER or AGENT The foregoing instrument was acknowledged before me this 19 day of / 20 ( 1 , by )d ?Ay�yf:> , w- who personally known to me or who has produced r� DC -`y rLrL as identification and who did take an oath. �101111111111!!! NOTARY PUBLIC: vis Sign: - ' s Print: CONTRACTOR The foregoing instrument was acknowledged before me this day of , 20 , by who is personally known to me or who has produced as , identification and who did take an oath. NOTARY PUBLIC: Print: Seal: Seal: ***rsss**•**:.****�*s******* *:: *****•s**r*+erg******�**�**sr�**rs**s**s**s****:**.*****.^*-*ss**s*..ss:**�** APPROVED BY Plans Examiner COD Zoning z Structural Review Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER ,BUILDER DISCLOSURE STATEMENT NAMdMMAY I - rY�Ory 1` DATE: � ) � I 141 ADDRESS: / Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial N e 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial-A11�1 3. 1 understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial&R. . 4. 1 understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. Initial 5. 1 understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial' 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial A- 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. 1 understand that I may not delegate the responsibility'for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. Initial_ 9. 1 agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial-M_ 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.myfloridalicense.com/dbpr/pro/cilb/index.html Initial 11. 1 am aware of, and consent to; an owner -builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: Initial .i 12. i agree to notify Miami Snores viiiage immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this day of 20l_ BY YA "I V_WrV 7 who was personally known to me or who has Produced there License or �- (�2i�%iCS� as identification. OWNER NOTARY ? C 0 o D o? U k to � Z { ►r i e n O t; O 9cr - >•:-I - - -- 1 tA �06 RP Is '06 ef • • • O a i L w LA 96 • • y 0 is • • . • • • • • C ] {.-� Jy .i !?4 h - ! � �• • •*00 Orr 2s of -• c . Jp OL n u CD V1 82 r to � ®a ,,,:.; • �., � � ?• v ! ;.i` y. �4'Ca4 nry Lr.arr �� 71 � '0 Q 3dCL _- I t�• of t+ lJ Ci rt rt 140 a �v r� O ►A at m Cd a U re & Yy 7 50 n ►-. . CL . ^�. Fes, j4? !•'• d 'j dO rs . O _ i i;c':-{. • �i }� _f'f 'S to J 24 [=7 Cd•' ''i. N r•r AV 00, ry 1 1Yfi' �yto =ram. fl^ 5 S 57+ �a QUALITY METAL PANELS GROMAL PO 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED MATH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADD111ONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WALL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 ------ 115 mph AS PER FBC 2017 SECTION 1616.2.1 OV WER. 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE Fy STEEL SHEETS A36 ----- 36 KSI STRUCTURAL TUBING A500 B 46 KSI 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. 4. ALL EXPOSED FERROUS METAL PANELS, RAILS AND POSTS TO BE OF FACTORY HOT DIP GALVANIZED AND FACTORY PAINTED WITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER. CALCULATIONS -,--,-S--C-E _. _._ _ � ___.­.-.._..__ _. -and In_ accordance with FBC 2017 and ASCE 7-10 Wind load Calculation: General Data Post Design Top and Bottom Design Category I L (ft) 4 2 1/2x2 1/2x16 gage steel galvanized 2x1x0.071 st galvanized_ Exposure C Hpost (ft) 6 A 500 A 500 (m- ph) 115 00 F st 46000 •Mmax Ib m 13997 __ Mmax Ib m 1166 I: 1 00 A-500,'F6(psi) 27600Zx m 3 (' ^) 0 75 _.. _ Sx (m^3) 0.086 Kd: 0 85 Fv (psi) 18400 fb (psi) Mmax/Sx fb (pst) Mmax/S_x h (ft) _. __ 6 FY (P�) fb (pst) 18662� fb (Psi) 13562 8 (psfJ: _. lid 16.2 A-36 Fb (psi) _36000 21600 fb (psi)<Fb OK _. fb (psi)<Fb OK __. Fv (psi) 14400 _ _ _._. W y _ _ Rail to Posts Connection Design _ _ Foundation Design (nonconstrained FBC 2017-1807.3.2.1 Actual Pullout 194.4 P 388.80 Lateral soil bearing 200 Allowable Pullout 200 Using 10-16 Hilt Kwik A 1.44 Fooil ng Diameter (ft) 1.583 OK Flex Screw d 3.00 For poles 1806.3.4 2 4'-0" MAX ri " TYR FENCE PLAN VMW SCALE: 3/4"=1'-0" 4'-0" MA I I - II 1 el I it III \\77, \ \\ \\ \\ \\ FENCE CONNECTIONS: - RAIL TO POSTS TO BE CONNECTED WITH (2) 10-16 KWIK FLEX SCREW by HILT] OR APPROVED EQUAL ACCESS HOLE AT RAILS TO BE PROVIDED FOR CONNECTION, OR BE d" WELD 1" WELD LENGTH IN 2 OPOSITE SIDES MINIMUM. - PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET, 2 TOP do 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILT] OR APPROVED EQUAL, OR BY U L 1/4" PUDDLE WELDS. U TYP. FFINCE H". VW SCALE: 3/4"=1'-0" o•� S=0.124 IN' S = 0.0863 IN' 0.08 f l Mmax=16.2•6•.5•4•4/8 Mmax=16.2s6•.5•4•4/B I =1 166 ,#-in =1 166 #-in S=0.47 IN' M Aw=Mn/n , M AsD=Mn/0 , S=0.48 IN' Z=0.58 IN Mn=Fy►S 0 =1.67 Mn=Fy*S 0 =1.67 Z=0.60 IN' Mmax=16.2.4.6.6/2 M AsD=2 673 #--in M AsD=2 170 #--in Mmax-16.2•4;6►6 Mmax < M ASD Mmax < M Aso =13 997 #-in N =13 997 #-in M AsD=Mn/0 , c'4 0.04 M AsD=Mn/0 , Mn=Fy*Z , 0 =1.67 II a Mn=FyZ , 0 =1.67 M AsD=16 000 #-in M ASD=16 530 #-in Mmax < M Aso Mmax < M ASD 2" L 2" 2 1 /2 POSTS (16 GA) RAILS (16 GA) ALTERNATIVE ALTERNATIVE RAILS (19 GA) POSTS (16 GA) 6 1 /8" c MAM SCALE: 1 1 /2'=1'-0" 2xlx16 GA GALVANIZED STEEL TUBE RAIL TOP MEMBER 24 GA (MIN.) GALVANIZED METAL SHEET 2.5x2.5x16 GA. GALVANIZED STEEL POST SPACED O 4'-0" MAX. O.C. i 2006 GA GALVANIZED STEEL TUBE RAIL BOT. MEMBER 3000 PSI CONCRETE FOOTING 012"x4'-O" DEEP OR 019"x3'-O" DEEP OR 024"x2'-6" ULLP 012'x2'-9" DEEP (•) (•) SOIL SHALL BE VERIF]ED TO BE CONSISTENT WITH THE MENTIONED CHARACTERISTICS. A FLORIDA LICENSED ENGINEER SHALL VISUALLY INSPECT AND PROVIDE A CERTIFIED LETTER ATTESTING SO. Z=0.0065 IN' Mmax=16.2•(6.125/12)•3.33*3.33.0.125.12 =135 #-in M AsD=Mn/0 , Mn=FyZ 0 =1.67 M AsD=140 #-in Mmgx < M ASD 6,A" PICKETS (30 GA) MINIMUM Copy Ref# 1 j • • QDLi .W sa• • n a n �• • •• 11! ice•• • •� •••• • to • • • J LJ Q 0. ti r v, J Q W r E F- J � Q � 0 ir>yf If ❑ALEXIS MARTMEZ,PE ❑GONZALO A. PAZ,PE 611112019 JC SD-1 QUALITY METAL PANELS 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2.IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET NTH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 - - - - - - 115 mph AS PER FBC 2017 SECTION 1616.2.1 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE Fy STEEL SHEETS A36 ----- 36 KSI STRUCTURAL TUBING A500 B 46 KSI 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. 4. ALL EXPOSED FERROUS METAL PANELS, RAILS AND POSTS TO BE OF FACTORY HOT DIP GALVANIZED AND FACTORY PAINTED WITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER. CALCULATIONS In accordance with FBC 2017 and ASCE 7-10, Wind Speed from FBC 2017, Chapter 16, Section 1616 2 1 w115 mph Wind load Calculation: General Data. DL(psf) 5.._ Top and Bottom Design V (mph) 115 00 Fence -Sp an(ft) . 4 Gate Span(ft): 4 _ (Gate Span = Gate Leaf, not opening) 2xlx0 071 st galvanized Ex osure^ C Hpost (ft) 6 Post Design A 500 Gust Factor 0.85 Fy (psi) 46000 Steel galvanized A 500 Mmax. (lb -in) 2608 Cf: 1.30 A-500 Fb (psi) 27545 Section Mw,"d MDR M.... (lb -in) 4 (inA3)Yfb (psi) (inA3) 0.124 Kd: 0.85 Fv (psi) 18400 2.5x2.5x16Ga _ . _ 14012 _ . .__ .._ _ _ _ ySx 2880 14305 0 58 24663 7 fb (psi) Mmax/Sx h (ft)...� Fy (Psi) 36000 fb (Psi)_ ... _._. .. _ --- 21029.6 Kz: 0.85 A-36 Fb (psi) 21600 fb (psi)<Fb OK fb (psi)<Fb OK _ ....._ __.._._._._.._.�_ ____.;_ ....,.. _ _ ______.._..__._.�._.._..___ _ _ Rail to Posts Connection Design o Foundation Desian (nonconstrained FBC 2017-1807.3.2.1) (2017 .1806.2) _ ...__ .. _ . _.__ _. _..__.. _ _. ,. _ _._. _,. Actual Pullout 32 _ _ P 583.83 _. _. Lateral soil bearing 200 Allowable Pullou 200 Using 10-16 Hilti Kwik A 2.16 Footing Diameter (ft) 1,58333 OK Flex Screw d (Depth) 3.95 _ ._ .._. _._. For poles 1806.3 2 NEXT POST FENCE TO NEXT POST FENCE TO BE AT NO MORE THAN 4' 3'-0"/4'-0" MAX BE AT NO MORE THAN 4' 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) i GALVANIZED STEEL POST 2-1/2"x2-1/2"x16GA 24 GA. (MIN.) GALVANIZED METAL DURA FENCE 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) HINGES TO RESIST 180 LBS 2x1x16 GA. GALVANIZED STEEL FRAME GATE 0 (TD) I CONNECTIONS: - PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET, 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL. H ALL GATE FRAMES TO BE CONNECTED BY ALL AROUND FFIaILLE/T�W�ELLD. YR SCALE: 3/4"=1'-O" 2-1 /2"x2-1 /2"x16GA Tr• SO4ME Gh E PLN• • ii' "IlS=0.124 IN' Mmaxax=2 608 #-in S=0.47 IN' M Aso=Mn/0 , Z=0.58 IN' Mn=Fy*S 0 =1.67 Mmax=14 305 #-in M Aso=2 673 #-in Mmax < M Aso A M ASD=Mn/0 , Mn =Fy*Z 0 =1.67 M AsD=16 000 #-in I1 T Mmax < M ASo 2 r � 2" -4 POSTS (16 GA) RAILS (16 GA) X N x W < aO %ar N N••� iq d • • < X • • • • •• • • ¢ v • 0 1 •••• • • • • • •••• • •••••• •• •• • ••••• 3 KSI CONC. F130T1NG • 012"x4'-O" DEEP OR • i • 019"x3'-0" DEEP OP • • • _ 024"x2'-6" DEE%")- 0 APPLICABLE EXCLUSIVE ONLY FOR SEDIMENTARY AND FOLIATED ROCK \.; SOILS 012"x2'-9" DEEP(*) I (*) SOIL SHALL BE N VERIFIED TO BE CONSISTENT WITH THE MENTIONED CHARACTERISTICS. A FLORIDA LICENSED ENGINEER SHALL VISUALLY INSPECT AND PROVIDE A CERTIFIED LETTER ATTESTING SO. SCALE: 3/4"=1'-O" 0.06 Z=0.0065 IN' Mmax=16.2*(6.125/12) *3.33*3.33*0.125►12 S=0.48 IN' =135 #-in Z=0.60 IN' Mmax=14 305 #-in MnAsD=Mn/ n,=1.67 Aso=Mn/ M f2 M Aso=140 #-in , Mn=Fy*Z , 0 =1.67 Mmax < M Aso a M Aso=16 530 #--in Mmax < M Aso 2 1/2" ALTERNATIVE POSTS PICKETS (30 GA) MINIMUM (16 GA) Copy Ref# 19- ❑ALEXIS MARTINEZ,PE OGOKEALO A, PAZ K /6/11/2019 I'SD-2 QUALITY METAL PANELS COAL Num 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIL.S. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLE11ON OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENT'S OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 ------ 115 mph AS PER FBC 2017 SECTION 1616.2.1 OV WER. 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE Fy STEEL SHEETS A36 ----- 36 KSI STRUCTURAL TUBING A500 B 46 KSI 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. 4. ALL EXPOSED FERROUS METAL PANELS, RAILS AND POSTS TO BE OF FACTORY HOT DIP GALVANIZED AND FACTORY PAINTED WITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER. NEXT POST FENCE TO BE AT NO MORE THAN 4' 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) I GALVANIZED STEEL POST 2-1/2"x2-1/2" x14GA 24 GA. (MIN.) GALVANIZED METAL •I SHEET FENCE HINGES TO RESIST 180 LBS I 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) 3 KSI CONC. FOOTING 019"x4'-O" DEEP OR 024"x3'-9" DEEP OR 030"x3'-4" DEEP OR 036'x3'-0" DEEP (TYP) 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) 0'-0" 2x1A6 GA. GALVANIZED STEEL FRAME GATE (TYP) TIT ! !! I! I L K ! ! I HIDWIE U U ` 7/8 DIAM. SOLID BAR CANE BARS GATE CONNECTIONS • PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET, 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL. • ALL GATE FRAMES TO BE CONNECTED WITH 1/8- FILLET WELD ALL AROUND. i . DOME GAM iiW • W SCALE: 1 /2"=1'-0" SCALE: 1 /2"=1'-0" GALVANIZED STEEL POST 2}"x2j"x14GA NEXT POST FENCE TO BE AT NO MORE THAN V N i i n • •�•• •• N • •• •• • • 06 •• • • •• •• • • 3 K§I CONC FOOTING• 4 019)4'-QQ• QEEP 01f 024 xi erg" DEEP Of: r 030"x3'-4" DEEP • OR 036'x3'-0" DEEP (*) SOIL SHALL BE VERIFIED TO BE CONSISTENT WITH THE MENTIONED CHARACTERISTICS. A FLORIDA LICENSED ENGINEER SHALL VISUALLY INSPECT AND PROVIDE A CERTIFIED LETTER 24 GA. (MIN.) GALVANIZED METAL SHEET FENCE CALCULATIONS In accordance with FBC 2017 and ASCE 7-10, 11•0 S=0.124 IN' Z=0.0065 IN' Wind Speed from FBC 2017, Chapter 16, Section 1616.2.1 v=115 mph IMmax=4 Z=0.155 IN' Mmax=16.2*(6.125/12)•3.33*3.33•0.125*12 load Calculation: General Data: DL IP�)�Wind 5 Top and Bottom DeDesign 074 #-in =135 #-in V (mph): 115.00 Fence Span(ft): 4 Gate Span(ft): 5 (Gate Span = Gate Leaf, not opening) 2xlx0.071 st galvanized S=0.57 IN' M AsD=Mn/() , M AsD=Mn/D , Exposure: C Hpost (ft) 6 Post Design A-500 Z=0.71 IN' Mn=Fy*Z D =1.67 Mn=Fy*Z Q =1.67 Gust Factor 0.85 Fy (psi) 46000 Steel galvanized A-500 Mmax. (Ib-in) 4074 Mmax=16 393 #--in M ASD=4 269 #-in Mmax < M Aso M AsD=140 #-in Mmax < M ASD Cf: 1.30 A-500 Fb (psi) 27545 Section MvWnd ,,,,. Ib-in Mpg M ( ► Zx (in"3) fb (psi) Zx (in"3) 0.155 M A=Fy*Z (1 Kd: 0.85 Fv (psi) 18400 2.5x2.5x14Ga 15764 4500 16393 0.71 23089.1 fb (psi) Mmax/Sx Mn Fy0 =1.67 M Aso=19 550 #-in 0•06 � 11 h (ft): 6.00 Fy (psi) 36000 fb (psi) 26287 Mmax < M Aso Kz: 0.85 A-36 Fb (psi) 21600 fb (psi)<Fb OK fb (psi)<Fb OK yz (psi): 16.2 Fv (psi) 14400 6YA Rail to Posts Connection Design Foundation Design (nonconstrained FBC 2017-1807.3.2.1) (2017-1806.2) 'r Actual Pullout 32 P 583.83 Lateral soil bearing 200 L 2 J" L 2" Allowable Pullou 200 Using 10-16 Hilti Kwik A 2.16 Footing Diameter (ft) 1.58333 POSTS (14 GA) RAILS (16 GA) PICKETS (30 GA) MINIMUM OK Flex Screw d (Depth) 3.95 For poles 1806.3 2 Copy Ref # 19-0485 rl: �':LL ; o o'` N J W Q a C 0 Q n o I � a W E 0 0 Q 0