Loading...
ELC-19-1777Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: Location Address Parcel Number 10653 NE 6TH AVE, Miami Shores, FL 33138 1122310120010 Contacts Permit NO.: ELC-08-19-1777 Permit Type: Electrical - Commercial Work Classflcatfon: Alteration Permit Status: Approved Expiration: 02/03/2020 MIAMI COUNTRY DAY SCHOOL INC Owner UNITED FIRE PROTECTION INC Contractor MIAMI COUNTRY DAY SCHOOL INC DAVID NORRIS 601 NE 107 ST, MIAMI, FL 331617165 1200131 CT N, ST. PETERSBURG, FL 33716 Other: 3057592843 Business: 9545720119 mfoucher@united-fire.com Description: MODIFICATIONS TO AN EXISTING FIRE ALARM Valuation: $ 53,000.00 Inspection Requests: 4949 SYSTEM Total Sq Feet: 0.00 Fees Amount Application Fee - Other $200.00 CCF $31.80 DBPR Fee $23.85 DCA Fee $15.90 Education Surcharge $10.60 Permit Fee $1,390.00 Scanning Fee $24.00 Technology Fee $39.75 Total: $1,735.90 Payments Date Paid Amt Paid Total Fees $1,735.90 Check # 7715 08/01/2019 $200.00 Check # 7721 08/06/2019 $1,535.90 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is regulating construction and zoning. Futhermore, I authorize the above r ate and that all work will be done in compliance with all applicable laws contractor 0 thew tated. I?,-R-G-jq Authorized Signature: Owner / Applicant / Contractor / Agent Date August 06, 2019 Page 2 of 2 BUILDING IVED Miami Shores Village A1,61 1,2019 Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762.4949 FBC 20 -� Master Permit No. s" r " 1l I PERMIT APPLI TION sub Permit No. ❑BUILDING ELECTRIC ROOFING REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 10653 Ne 6th ave City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11-2231-012-0100 Is the Building Historically Designated: yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Miami Country day school Phone#: Address: 601 NE 107th St City: Miami State: Florida Zip: 33161 Tenant/Lessee Name: Email: O5- 7T1- 72-©o CONTRACTOR: Company Name: United Fire Protection Phone#: 954 572 0119 Address: 3247 Tech Drive City: St. Petersburg State: florida Zip: 33716 Qualifier Name: David Chadwick Norris Phone#• State Certification or Registration #: EF-0001185 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: —city: State: Value of Work for this Permit: $ 53000 Square/Linear Footage of Work: Zip: Type of Work: ❑ Addition ❑■ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: modifications to an existing fire alarm system Specify color of color thru tile: Submittal Fee $ I Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zi Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. J Signature Signature — OWNER or AGENT CONTRACTOR The foreg i instrument was acknowledged before me this 7C� (� The foregoing instrum nt was acknowledged before me this �0 day of ____• 20 by day of 20 Lal by In YY�S W' CC�� who is personally known to 1 �t tcl C who isnersonally know Me or who has produced as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign' 0 , / Sign: /n� I` n Print: & 1 e Print: lift Seal: ,.GYP,, ATAi IE KAYLA GARCIA Seal: : 't�Y°'• ROB ERTDDELGADO ..•'iP ° ; Notary Public •State o1 Florida s N GG 019156 Commissioiahona1Not*ar�*A*s*n. : r° ��`� =: Notary Public-StateofFlorida :. ; ` _ Commission a GG 070239 My Comm. Expires Jun 2,2021 My Comm. Exires Auk 1 2020 Bonded through NationalNotaryAssn. ##i## #'f ��'�#a►###########�#########f•i###i###ii+Y hrough APPROVED BY l (plans Examiner Zoning Structural Review Clerk (RevisedO2/24/2014) • • M�� COUNTRY DAY SCHOOL July 7, 2019 Miami Dade County RE: 601 NE 107th Street, Miami, FL 33161 To Whom It May Concern: Mr. James Connor, Interim Chief Operating Officer, is an authorized signer on behalf of the corporation, Miami Country Day School, Inc., owner of the above addressed property. Christopher Bellows, President Board of Trustees Miami Country Day School, Inc. 601 Northeast 107 Street I Miami, Florida 33161 1 305-779-7200 1 www.miamicountryday.org Every Student. Every Day. 7/30/2019 Detail by Entity Name DIVISION OF CORPORATIONS org1 fill ojflrifl!.�Iwt tl Department of State / Division of Corporations / Search Records / Detail By Document Number / Detail by Entity Name Florida Not For Profit Corporation MIAMI COUNTRY DAY SCHOOL, INC. Filing Information Document Number 744085 FEI/EIN Number 59-1278987 Date Filed 08/31/1978 State FL Status ACTIVE A Last Event REINSTATEMENT Event Date Filed 10/21/2010 Principal Address 601 N.E. 107TH STREET MIAMI, FL 33161 Changed: 10/21 /2010 Mailing Address 601 N.E. 107TH STREET MIAMI, FL 33161 Changed: 01 /17/2012 Registered Agent Name & Address HUFFORD, MARIANDL C 601 N.E. 107TH ST MIAMI, FL 33161 Name Changed: 06/27/2019 Address Changed: 05/18/2009 Officer/Director Detail Name & Address Title DP CHRISTOPHER, BELLOWS 134 NE 102 STREET MIAMI SHORES, FL 33138 search.sunbiz.org/Inquiry/CorporationSearch/Search Resu ltDetail?inqu irytype=EntityName&d irectionType=Initial&searchNameOrder=M IAM ICOU NTR... 1 /3 7/'0/2019 I u1e u0 LAZENBY, MATTHEW 420 Lincoln Road Suite 320 MIAMI BEACH, FL 33139 Title DT SAAD,SOL 6950 NW 25TH WAY BOCA RATON, FL 33496 Title CEO HEAD OF SCHOOL HUFFORD, MARIANDL C 601 N.E. 107TH STREET MIAMI, FL 33161 Title 1 VP BROD, CLAUDIA i 65 PALM AVE. MIAMI BEACH, FL 33139 f Title 2VP MOORE, JAMES 5905 NORTH BAY ROAD MIAMI BEACH, FL 33140 search) Annual Reports Report Year Filed Date 2018 01 /16/2018 2019 01 /08/2019 2019 06/27/2019 Document Images Detail by Entity Name 06/27/2019 -- AMENDED ANNUAL REPORT View image in PDF format 01/08/2019 -- ANNUAL REPORT -- View image in PDF format 07/13/2018 -- Reg. Agent Change — View image in PDF format —� 01/16/2018 --ANNUAL REPORT _ View image in PDF format 01/10/2017 -- ANNUAL REPORT View image in PDF format 01/29/2016 --ANNUAL REPORT View image in PDF format -- -- ANNUAL REPORT j02/26/2015 View image in PDF format 02/25/2014 — ANNUAL REPORT View image in PDF format ------------- 02/22/2013 -- ANNUAL REPORT View image in PDF format 01/17/2012 --ANNUAL REPORT View image in PDF format 01/04/2011 --ANNUAL REPORT View image in PDF format 10/21/2010 -- REINSTATEMENT View image in PDF format 05/19/9009 -- Ran Anent Change View image in PDF format sunbiz.org/Inquiry/CorporationSearch/SearchResultDetaiI?inquirytype=EntityName&directionType=Initial&searchNameOrder=MIAMICOUNTR 2/3 1 NITED FIRE Providing World Class Service Fire Alarm System ' Modifications ." ... ...... �....� For: .... Miami Country Day School -Business center 10653 NE 6th Avenue Miami Shores, FL 33138 Headquarters 12001 31s` Court N.• St. Petersburg, FL 33716 • (727) 471-0860 • Fax (727) 471-0861 www.united-fire.com DN-7111:M • A-13 NFS2.640(E) 0NOT1 F1 E R® Intelligent Addressable Fire Alarm System by Honeywell Intelligent Fire .. ,-. General MERL The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. The NFS2-640's modular design makes system planning easier. The panel can be configured with just a few devices for small build- ing applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional periph- eral equipment to suit the application. A host of other options are available, including single- or multi- channel voice; firefighter's telephone; LED, LCD, or PC -based graphic annunciators; networking; advanced detection products for challenging environments; wireless fire protection; and many addi- tional options. NOTE. Unless called out with a version -specific "E" at the end of the part number, `NFS2-640" refers to models NFS2-640 and NFS2-640E, similarly, "CPU2-640" refers to models CPU2-640 and CPU2-640E. Features • Certified for seismic applications when used with the appropri- ate seismic mounting kit. • Approved for Marine applications when used with listed com- patible equipment. See DN-60688. • One, expandable to two, isolated intelligent Signaling Line Cir- cuit (SLC) Style 4, 6 or 7. • Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820. • Up to 159 detectors and 159 modules per SLC; 318 devices per loop/636 per FACP or network node. — Detectors can be any mix of ion, photo, thermal, or multi -sen- sor; wireless detectors are available for use with the FWSG. — Modules include addressable pull stations, normally open contact devices, two -wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG. • Standard 80-character display, 640-character large display (NCA-2), or display -less (a node on a network). • Network options: — High-speed network for up to 200 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX - Works, NFS-3030, NFS-640, and NCA). — Standard network for up to 103 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX - Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020). Up to 54 nodes when DVC- EM is used in network paging. • 6.0 A switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sen- sor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Multiple central station communication options: — Standard UDACT — Internet — Internet/GSM • 80-character remote annunciators (up to 32). NFS2-640 • EIA-485 annunciators, including custom graphics. • Printer interface (80-column and 40-column printers). • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm -only file. • Alarm Verification selection per point, with automatic counter. • Presignal/Positive Alarm Sequence (PAS). • Silence inhibit and Auto Silence timer options. • March time/temporal/California two -stage coding/strobe syn- chronization. • Field -programmable on panel or on PC, with VeriFire Tools pro- gram check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 — 200 AH batteries. • Non -alarm points for lower priority functions. • Remote ACK/Signal Silence/System Reset/Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Surface Mount Technology (SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. • Support for SCS Series smoke control system in HVAC mode. NCA-2 AS PRIMARY DISPLAY • Backlit, 640-character display. • Supports SCS Series smoke control system in FSCS mode when SCS is connected to the NCA-2 used as primary display. • Supports DVC digital audio loop. • Printer and CRT EIA-232 ports. • EIA-485 annunciator and terminal mode ports. • Alarm, Trouble, Supervisory, and Security relays. DN-7111:M • 3/24/17 — Page 1 of 8 FLASHSCANO INTELLIGENT FEATURES • Polls up to 318 devices in less than two seconds. • Activates up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high -precision protocol (U.S. Patent 5,539,389). • Manual sensitivity adjustment — up to nine levels. • Pre -alarm ONYX intelligent sensing — up to nine levels. • Day/Night automatic sensitivity adjustment. • Sensitivity windows: — Ion — 0.5 to 2.5%/foot obscuration. — Photo — 0.5 to 2.35%/foot obscuration. — Laser (VIEW — 0.02 to 2.0%/foot obscuration. — Acclimate PIusTM — 0.5 to 4.0%/foot obscuration. — IntelliQuadTM —1.0 to 4.00/o/foot obscuration. — Intell!QuadTM PLUS — 1.0 to 4.00/./foot obscuration • Drift compensation (U.S. Patent 5,764,142). • Degraded mode — in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. • Multi -detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). • Automatic detector sensitivity testing (NFPA-72 compliant). • Maintenance alert (two levels). • Self -optimizing pre -alarm. FSL-751 (VERY INTELLIGENT EARLY WARNING SMOKE DETECTION TECHNOLOGY • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non -smoke signals (U.S. Patent 5,831,524). • Addressable operation pinpoints the fire location. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW -PROFILE INTELLIGENT MULTI -SENSOR • Detector automatically adjusts sensitivity levels without opera- tor intervention or programming. Sensitivity increases with heat. • Microprocessor -based technology; combination photo and ther- mal technology. • Low -temperature warning signal at 40°F t 5°F (4.44°C t 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI -CRITERIA DETECTOR • Detects all four major elements of a fire (smoke, heat, CO, and flame). • Automatic drift compensation of smoke sensor and CO cell. • High nuisance -alarm immunity. • • • • INTELLIGENT FAAS7,DG ® DETECTORS ISAO, FSA--0,• FSA- • "' �' 20000 AND FSA-20000P " ' " ' • • Connects directly to the SLC lodp df �Erfipatible ONYX series • • • • • • panels. ••.•.• • • • • Provides five event thresholds thei.can be indivWrrarly pro- : • �: grammed with descriptive labels'fgr gWtFol-by-et tl pjdtjram- 0000. ming; uses five detector addresses. • • •••••• • • ••••• • Uses patented particle separator and field-replaseabie.filter to remove contaminants. " " ' """ • • Advanced algorithms reject com;80fl Lance condititfns ' 0 • FSA-5000 covers 5,000 square f6et throrigh one�jp�p•; 0 """ • FSA-8000 covers 8,000 square fget tIV8LWh one pipe. :0.0 • • FSA-20000 covers 28,800 squar%•feet•throug: oj*•to four • • pipes. 0000 SLC Intelligent Loop 1 Up to 32 remote displays _ t� 6 — —DEVICES ® 0 0 0 0 0 0 •..e., FWSG FSC-851 IntelliQuad NBG-12LX 'f ` XP6/10 1/0 Modules FAPT-851 Acclimate PLUS o00o FSL-751 FlashScan VIEW FMM-1 FCM-1 .... FSP-851 Photo IDC NAC FSI-851 Ion FDU-80 FST-851 Thermal FRM-1 LCD2-80 FSA-8000 Relay Contact ...etc. SLC Intelligent Loop 2 ® EIA-485 <DM-R2 display EIA-485 2048 annunciator/control points OR r ■ ■ o NCA-2 OR ACM-8R ACM/AEM-24AT LDM-32 with no display Relay Control LED Annunciator Custom Graphics Dual phone 01 Optional636-point UDACT lines to Central Station Sample NFS2-640 I/t� System "C" cabinet size shown 7111Wok-2014—f PRN Series Printer Options Page 2 of 8 — DN-7111:M • 3/24/17 • FSA-20000P covers 28,800 square feet through one to four pipes. Supports addressable pipes to pinpoint location of alarm events FCO-851 INTELLIOUADTM PLUS ADVANCED MULTI -CRITERIA FIRE/CO DETECTOR • Detects all four major elements of a fire. • Separate signal for life -safety CO detection. • Optional addressable sounder base for Temp-3 (fire) or Temp-4 (CO) tone. • Automatic drift compensation of smoke sensor and CO cell. • High nuisance -alarm immunity. SWIFT WIRELESS • Self -healing mesh wireless protocol. • Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices. • Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES • Ten independent hazards. • Sophisticated cross -zone (three options). • Delay timer and Discharge timers (adjustable). • Abort (four options). • Low-pressure CO2 listed. DIGITAL VOICE AND TELEPHONE FEATURES • Up to eight channels of digital audio. • 35, 50, 75, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series; NCA-2 required as primary display). • Solid-state digital message generation. • Firefighter telephone option. • 30- to 120-watt high -efficiency amplifiers (AA Series). • Backup tone generator and amplifier option. • NFS2-640 can also integrate with the FirstCommand Emer- gency Communications System. See DN-60772. HIGH -EFFICIENCY OFFuNE SWITCHING 3.0 A POWER SUPPLY (6.0 A /N ALARM) • 120 VAC (NFS2-640); 240 VAC (NFS2-640E). • Displays battery current/voltage on panel (with display). FlashScan, Exclusive World -Leading Detector Protocol At the heart of the NFS2-640 is a set of detection devices and device protocol — FlashScan (U.S. Patent 5,539,389). FlashScan is an all -digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS2-640 to have the largest device per loop capacity in the industry — 318 points — yet every input and output device is sampled in less than two seconds. The micropro- cessor -based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS2-640 with industry -leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high-speed micro- computer used by the NFS2-640. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces mainte- nance requirements by allowing the system to automatically per- form the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove tran- sient noise signals, such as those caused by electrical interfer- ence. Maintenance Warnings: When the drift compensation performed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Main- tenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change auto- matically between day and night. Nine levels of pre -alarm sensitiv- ity can also be selected, based on predetermined levels of alarm. Pre -alarm operation can be latching or self -restoring, and can be used to activate special control functions. Self -Optimizing Pre -Alarm: Each detector may be set for "Self - Optimizing" pre -alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog r89dlr!gs over a long period of time, and setting tre p12Lilarm IevRI JM above • • • • • • these normal peaks. • • • • • • . • Cooperating Multi -Detector Sensivigx" patented •feature of • •. o • ONYX intelligent sensing is the abQty p:a Smoke sensor to con- . • sider readings from nearby sensors in •ma king alarm or pre -alarm e • • • • e decisions. Without statistical sacrifise in tiro ability.to resis= false alarms, it allows a sensor to increase V tfisitivity to MC C" smoke • • • • • by a factor of almost two to one. 000000 • . •.:.. • • • •••••• •• •• • •••••• Field Programming Opt{plps.. • • Autoprogram is a timesaving feature. ThC FACP. learrys" what • • ••: • devices are physically connected and automaticallyleads•them in the program with default values for 0111 paraaleters. Requiring less j....; than one minute to run, this routine aHt%s tRe user ib Vl @ ilmost • • immediate fire protection in a new installation, even ddm* a por- tion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS2-640, like all NOTIFIER intelligent panels, has the exclusive feature of program creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2- 640 software is such that each point entry carries its own program, including control -by -event links to other points. This allows the pro- gram to be entered with independent per -point segments, while the NFS2-640 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confi- dence in the site -specific software. It is Windows® -based and pro- vides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS2-640 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS2-640's flexible system design. Rows: The first row of equipment in the cabinet mounts in the chassis shipped with the FACP. Mount the second, third, or fourth rows of equipment in a CHS-4 series chassis or, for Digital Voice Command products, in CA-1 or CA-2. (For DVC-EM and DAA2/ DAX components see DVC Manual, for DS series components see DS-AMP Manuat,, for DVC-AO applications, see AA Series Installa- tion Manuao. Other options are available; see your panel's installa- tion manual. Wiring: When designing the cabinet layout, consider separation of power -limited and non -power -limited wiring as discussed in the NFS2-640 Installation Manual. Positions: A chassis offers four basic side -by -side positions for components; the number of modules that can be mounted in each position depends on the chassis model and the size of the individ- ual module. There are a variety of standoffs and hardware items available for different combinations and configurations of compo- nents. DN-7111:M • 3/24/17 — Page 3 of 8 It is critical that all mounting holes of the NFS2-640 are secured with a screw or standoff to ensure continuity of Earth Ground. Layers: The control panel's chassis accepts four layers of equip- ment, including the control panel. The CPU2-640 fills three posi- tions (left to right) in the first -installed layer (the back of the chassis); its integral power supply occupies the center two posi- tions in the next two layers; the optional display occupies (the left) two positions at the front, flush with the door. Some equipment, such as the NCA-2, may be mounted in the dress panel directly in front of the control panel. The NCA-2 can be used as a primary display for the NFS2-640 (use NCA/640-2-KIT) by directly con- necting their network ports (required in Canadian stand-alone applications); see NCA-2 data sheet for mounting options (DN- 7047). Expansion: Installing an LEM-320 Loop Expander Module adds a second SLC loop to the control panel. The LEM-320 is mounted onto the CPU2-640, occupying the middle -right, second (back) slot on the chassis. Networking: If networking two or more control panels, each unit requires a Network Communication Module or High -Speed Net- work Communication Module. (HS-NCM can support two nodes; see "Networking Options" on page 4). These modules can be installed in any option board position (see manual), and additional option boards can be mounted in front of the network communica- tion modules. KDM-R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout, see figure). 12 LED indicators: Power; Fire Alarm; Pre -Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Disabled; Control Active; Abort; Pre -Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long -life LED backlight. Product Line Information • "Configuration Guidelines" on page 4 • "Networking Options" on page 4 • "Auxiliary Power Supplies and Batteries" on page 4 • "Audio Options" on page 5 • "Compatible Devices, EIA-232 Ports" on page 5 • "Compatible Devices, EIA-485 Ports" on page 5 • "Compatible Intelligent Devices" on page 5 • "Enclosures, Chassis, and Dress Plates" on page 6 • "Other Options" on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On sys- tems with one FACP (one CPU2-6401-640E), display options are the KDM-R2 or the NCA-2. On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX - Works annunciation device is required. Other options listed as follows; KDM-R2: 80-character backlit LCD display with QWERTY pro- gramming and control keypad. Order two BMP-1 blank modules and DP-DISP2 mounting plate separately. Requires top row of a cabinet. Required for each stand-alone 80-character display sys- tem. The KDM-R2 may mount in network nodes to display `local" node information as long as at least one NCA-2 or NCS/ONYX- Works network display is on the system to display network infor- mation. (Non -English versions also available: KDM-R2C for ULC application, KDM-R2-FR, KDM-R2-PO, KDM-132-SP.) NCA-2: Network Control Annunciator, 640 characters. On single CPU2-6401-640E systems, the optional NCA-2 can be used as the Primary Display for the panel and connects directly to the CPU2- 6401-640E. On network systems (two or more networked fire panel nodes), one network display (either NCA-2 or NCS/ONYXWorks) is required for every system. On network systems, the NCA-2 con- nects to (and requires) a standard Network Communication Mod- ule or High -Speed Network Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting Page 4 of 8 — DN-7111:10 •3/24/17 options include the DP-DISP2, ADP-4B, or in an annunciator box, such as the ABS-21). In CAB-4 top -row applications, a DP-DISP2 and two BMP-1 blank modules are required for mounting. Required for NFS2-640 applications employing the DVC-EM with DAL devices. Non -English versions are available. NCA-2 are avail- able for ULC applications. For marine applications, order NCA-2- M; for non-English Marine applications, order NCA-2-M and the appropriate KP-KIT-XX. See DN-7047. CPU2-640: Central processing unit (CPU) with integral 3.0 A (6.0 A in alarm) power supply for an NFS2-640 system. Includes con- trol panel factory -mounted on a chassis; one Signaling Line Circuit expandable to two; documentation kit. Order one per system or as necessary (up to 103 network nodes) on a network system. (Non - English versions also available: CPU2-640-FR, CPU2-640-PO, CPU2-640-SP.) CPU2-640E: Same as CPU2-640 but requires 240 VAC, 1.5 A, (3.0 A in alarm). (Non -English versions also available: CPU2- 640E-PO, CPU2-640E-SP.) • • • • NCA/640-2-KIT: Bracket installation•kit required to �nvmPt•NCA-2 to the CPU2-640/-640E's standard A&Ois.: •. • DP-DISP2: Dress panel for top row•irembinet wi%AA-640/ 640E installed. • ADP2-640: Dress panel for middle roWr6W jh CPU2-6444fJ60E. BMP-1: Blank module for unused m84W(b positions. • • • • • • BP2-4: Battery plate, required. • • • • • • • • LEM-320: Loop Expander Module.•Gxpesds each:11992 640 to two Signaling Line Circuits. See DNMf 0 NETWORKING OPTIONS ' • NCM-W, NCM-F: Standard Netwoj c Cprfipiunicatibns Modules. Wire and multi -mode fiber versions avei4ablet See DN-6864. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed NEt AFk Com- munications Modules that can connect to two nodes. Wire, single - mode fiber, multi -mode fiber, and media conversion models are available. See DN-60454. RPT W, RPT F, RPT WF: Standard -network repeater board with wire connection (RPT W), multi -mode fiber connection (RPT F), or allowing a change in media type between wire and fiber (RPT WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN-GW- EM.) See DN-60499. NWS-3: NOTI•FIRE•NETTM" Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See DN-60756. VESDA-HLI-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTI•FIRE•NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10.0 A addressable charging power supply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S6/S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. NFS2-640 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS NOTE. For mounting hardware, see 'Enclosures, Chassis, and Dress Plates" on page 6 and peripheral data sheets. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 min- utes at high quality) digital audio. Capable of playing up to eight simultaneous messages when used with Digital Audio Loop (DAL) devices. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN-60726. DS-DB: Digital Series Distribution Board, provides bulk amplifica- tion capabilities to the DVC-EM while retaining digital audio dis- tribuition capabilities. Can be configured with up to four DS-AMPs, supplying high-level risers spread throughout an installation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; sta- tus LEDs and 24 user -programmable buttons. See DN-7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Amplifier, part of the DS-DB system. See DN-60663. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC- EM, DS-DB distribution board, and DAX and DAA2 Series amplifi- ers. See DN-60633. DVC-AO: DVC Analog Output board provides four analog output circuits for use with AA Series amplifiers. Four -channel operation supported. See DN-7045. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1 SA) stand-alone cab- inets. See DN-6728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic switchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier provides up to 120 watts of 25 VRMS audio power for the NFS-640. The amplifier contains an inte- gral chassis for mounting to a CAB-64, -C4, or -D4 backbox (con- sumes one row). Switch -mode power. Includes audio input and amplified output supervision, backup input, and automatic switcho- ver to backup tone. Order the AA-100 for 70.7 VRMS systems and 100 watts of power. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series ampli- fiers are compatible with DVC-EM systems running SR4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN-60257. NFC-25/50: 25 watt, 25 VRMS, emergency Voice Evacuation Con- trol Panel (VECP) with integral commercial microphone, digital message generator, and sing le -/dual -channel Class A or Class B speaker circuits. See DN-60772. COMPATIBLE DEVICES, EIA-232 PORTS PRN-7: 80-column printer. See DN-60897. VS4095/5: Printer, 40-column, 24V. Mounted in external backbox. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA-485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered - up switch selection) by point to be red, green, or yellow; the Trou- ble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm LEDs can be programmed (by powered -up switch selection) in groups of 24 to be red, green, or yellow. Expandableio 99 points with one AEM-48A. See DN-6862. • • • • • • AEM-48A: Same LED capabilities 99 ACM-48A,, ft,;M0 the ACM-48A to 96 points. See DN-6869.9 • • • • • • • ACM-8R: Remote Relay Module witti";* form-C contacts. Can be located up to 6,000 ft. (1828.8 m) fsoeapanel on fow"res. See DN-3558. • • • • FDU-80: Terminal mode. 80-cha&VW,•,backlit ._CD •display. Mounts up to 6,000 ft. (1828.8 m) from •pa nel. Up td32perlFACP. See DN-6820. • ••••• • • •••••• LCD2-80: Terminal and ACS mode. i60 oUIcter, backlit LCD dis- • play. Mounts up to 6,000 ft. (1828.$ m) frorfi panel: Wg jQ g2 per • • • • • • FACP. See DN-60548. • • • • • LDM: Lamp Driver Modules LDM-32,•LDWE32, �d L•DM-R32; • • remote custom graphic driver modules. See DN-0551•: • • SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L, SCE-8L; eight (expandable to 16) circuits (HVAC only). See DN-4818. TM-4: Transmitter Module. Includes three reverse -polarity circuits and one municipal box circuit. Mounts in panel module position (single -address -style) or in CHS2-M2 position. See DN-6860. UDACT2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides positive non -interfering successive zone coding. Microprocessor -con- trolled, field -programmable from IBM® -compatible PCs (requires optional programming kit). Up to 256 programmable codes. Mounts in BB-UZC or other compatible chassis (purchased sepa- rately). See DN-3404. COMPATIBLE INTELLIGENT DEVICES NOTE: A" suffix indicates ULC-Listed model. FWSG Wireless SWIFT Gateway: Addressable gateway supports wireless SLC devices. Not appropriate for ULC applications. See DN-60820. FSA-5000: Intelligent FAAST® XS Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 5,000 sq.ft. For Canadian applications, order FSA-5000A. FSA-8000: Intelligent FAAST® XM Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 8,000 sq.ft. For Canadian applications, order FSA-8000A. See DN-60792. FSA-20000: Intelligent FAAST2) XT Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 28,800 sq.ft. For Canadian applications, order FSA-20000A. See DN-60849. FSA-20000P FAAST® XT PRO Intelligent Aspiration Detector For applications up to 28,800 sq. ft. (2601 sq. m.) through one to four addressable pipes. See DN-60792 FSB-200(A): Intelligent beam smoke detector. See DN-6985. FSB-200S(A): Intelligent beam smoke detector with integral sensi- tivity test. See DN-6985. DN-7111:M • 3/24/17 - Page 5 of 8 FSC-851(A): FlashScan IntelliQuad Advanced Multi -Criteria Detector. See DN-60412. FCO-851(A): FlashScan IntelliQuad PLUS Advanced Multi -Crite- ria Fire/CO Detector. See DN-60689. FSI-851(A): Low -profile FlashScan ionization detector. See DN- 6934. FSP-851(A): Low -profile FlashScan photoelectric detector. See DN-6935. FSP-851T(A): FSP-851 plus dual electronic thermistors that add 135°F (57°C) fixed -temperature thermal sensing. See DN-6935. FSP-851R(A): FSP-851, remote -test capable. For use with DNR(W). See DN-6935. FST851(A): FlashScan thermal detector 135°F (57°C). See DN- 6936. FST 851 R(A): FlashScan thermal detector 135°F (57*C) with rate - of -rise. See DN-6936. FST851H(A): FlashScan 190°F (88°C) high -temperature thermal detector. See DN-6936. FAPT-851(A): FlashScan Acclimate Plus low -profile multi -sensor detector. See DN-6937. FSL-751(A): FlashScan VIEW laser photo detector. See DN- 6886. DNR(A): InnovairFlex low -flow non -relay duct -detector housing (order FSP-851 R separately). Replaces FSD-751 PL/FSD- 751 RPL. See DN-60429. DNRW(A): Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low -profile relay base. See DN-60054. B224BI: Isolator base for low -profile detectors. See DN-60054. B210LP: Low -profile base. Standard U.S. style. Replaces B710LP. See DN-60054. B501(A): European -style, 4" (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of pro- ducing a variety of tone patterns including ANSI Temporal 3. Com- patible with sychronization protocol. See DN-60054. B200S-LF: Low -frequency version of B200S. See DN-60054. B200SCOA: Based on B200SA, with added CO detector markings in English/French. For Canadian applications only. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN- 60054. B200SR-LF: Low -frequency version of B200SR. See DN-60054. FMM-1(A): FlashScan monitor module. See DN-6720. FDM-1(A): FlashScan dual monitor module. See DN-6720. FZM-1(A): FlashScan two -wire detector monitor module. See DN- 6720. FMM-101(A): FlashScan miniature monitor module. See DN- 6720. FTM-1(A): Firephone Telephone Module connects a remote fire- fighter telephone to a centralized telephone console. Reports sta- tus to panel. Wiring to jacks and handsets is supervised. See DN- 6989. FCM-1(A): FlashScan control module. See DN-6720. FCM-I-REL(A): FlashScan releasing control module. See DN- 60390. FRM-1(A): FlashScan relay module. See DN-6720. FDRM-1(A): FlashScan dual monitor/dual relay module. See DN- 60709. NBG-12LX: Manual pull station, addressable. See DN-6726. ISO-X: Isolator module. See DN-2243. ISO-6: Six Fault isolator module. For Canadian applications order ISO-6A. See DN-60844. XP6-C(A): FlashScan six -circuit supervised control module. See DN-6924. Page 6 of 8 - DN-7111:M • 3/24/17 XP6-MA(A): FlashScan six -zone interface module; connects intel- ligent alarm system to two -wire conventional detection zone. See DN-6925. XP6-R(A): FlashScan six -relay (Form-C) control module. See DN- 6926. XP10-M(A): FlashScan ten -input monitor module. See DN-6923. SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-4 Series Enclosure: NFS2-640 mounts in a standard CAB-4 Series enclosure (available in four sizes, "A" through "D"). Backbox and door ordered seperately; requires BP2-4 battery plate. A trim ring option is available for semi -flush mounting. See DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabi- nets are available in three sizes, "B" through "D". See &"-6Q229. . CAB -BM Marine System: Protects•equip6nent in s%*@4A and waterfront applications. Also order" Pp2M§ for syVgmj using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. • • • • • • • • • • CHS-4: Chassis for mounting up to f6'ur•AWt6Rs. • CHS-4L: Low -profile four -position 0,assis• Mounts two GA-30 amplifiers or one AMG-E and one AA-Je.0 • 0006 DP-1B: Blank dress panel. Provides!Vcr-fjont par" ":pused tiers; covers DAA2/DAX series or APR9eric9 amplifier! NFS-LBB: Battery Box (required forrAtt$ia:larger than26 AH). NFS-LBBR: Same as above but red' ' : ••.:. CHS-BH1: Battery chassis; holds tjo batteries. Mounts one the left side of DAA2 chassis. Se2D1\1-7646. • • • • • • CA-1: Chassis, occupies one tier of a CAB-4 SerieS'21rr!losure. The left side accommodates one DVC-EM and a DVC-KID (optional); and the right side houses a CMIC-1 microphone and its well (optional). See DN-7045, CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted on a half -chassis and one NCA-2 mounted on a half -chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMIC-1 microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 configuration: ADDR- B4, ADDR-C4, ADDR-D4 (below). CFFT-1: Chassis to mount firefighter's telephone and one ACS annunciator in a CAB-4 row. Includes TELH-1 firefighter's handset for the DVC-EM, chassis, phone well and mounting hardware. Order DP-CFFT dress panel separately. DP-CFFT: CFFT-1 dress panel. Requires BMP-1 if no ACS annun- ciator is installed. ADDR-B4*: Two -tier -sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-64. See DN-7045, DN-6857. ADDR-C4*: Three -tier -sized door, designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR-D4*: Four -tier -sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. *Use ADDR-B4/C4/D4 when CA-2 chassis is installed in top two rows with NCA-2 or BP-CA2. Use standard door when CA-2 is not installed in top two rows. For additional configuration information, see the DVC application guide on http:Hesd.notifier.com. DPA-1: Dress panel, used with the CA-1 chassis when configured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-26: Dress panel used with CA-2 chassis assembly. VP-2B: Dress panel, required when CA-2 chassis is installed in the top two cabinet rows. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN-7045. BP-CA2: Blank plate for CA-2 chassis. SEISKIT CAB: Seismic mounting kit. Required for seismic -certi- fied applications with NFS2-640 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SEISKIT LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. BACKBOXES NOTE: "C" suffix indicates ULC-Listed model. ABF-1 B(C) Annunciator Flush Box. • • • • • • ABF-1 DB(C) Annunciator Flush Box with Door. • • • • • • • • • • • • ABF-2B Annunciator Flush Box • • • • • • • ABF-2DB/C Annunciator Flush Box Door • • * 0 % with • ABF-4B Annunciator Flush Box ABS-1 TB(C) Annunciator Surface Box . �' • • �' • . ' ' ABS-1 B(C) Annunciator Surface Box • • ABS-213 Annunciator Surface Box •••••• • • • • • • • • • • ••••• ABS-21)(C) Annunciator Surface Box • • • • • • ABS-41)(C) Annunciator Surface Box • • • • BB-UZC: Backbox for housing the UZC-256 in ...... applications where the UZC-256 will not fit in panel enclosure. Black; for red, order . • • • • • • • • • • • • BB-UZC-R. •• • . •• „ • � . • OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411 UDAC: Digital alarm communicator. See DN-6746. IPDACT 2/2UD, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for Inter- net communications over customer -provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT2/2UD onto the panel chassis or CHS-4 series chas- sis. Use IPENC for external mounting applications. IPSPLT: Y adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mount- ing bracket; Red. For Black order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and sec- ondary ports of a DACT. For Canadian applications order IPGSM- 4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. DN-7111:M • 3/24/17 — Page 7 of 8 System Specifications SYSTEM CAPACITY • Intelligent Signaling Line Circuits ..................1 expandable to 2 • Intelligent detectors...............................................159 per loop • Addressable monitor/control modules .................... 159 per loop • Programmable software zones ............................................... 99 • Special programming zones...................................................14 • LCD annunciators per CPU2-640/-640E and NCA-2 (observe power) ................................................... 32 • ACS annunciators per CPU2-640/-640E................................ 32 addresses x 64 points • ACS annunciators per NCA-2.......................................32 addresses x 64 or 96 points NOTE. The NCA-2 supports up to 96 annunciator address points per ACM-24AT/-48A. ELECTRICAL SPECIFICATIONS • Primary input power: — CPU2-640 board: 120 VAC, 50/60 Hz, 5.0 A. — CPU2-640E board: 220/240 VAC, 50/60 Hz, 2.5 A. • Current draw (standby/alarm): — CPU2-640(E) board: 0.250 A. Add 0.035 A for each NAC in use. — KDM-R2: 0.100 A. — LEM-320: 0.100 A. • Total output 24 V power: 6.0 A in alarm. NOTE. The power supply has a total of 6.0 A. of available power. This is shared by all internal circuits. See Installation Manual for a complete current draw calculation sheet. • Standard notification circuits (4): 1.5 A each. • Resettable regulated 24V power: 1.25 A. • Two non-resettable regulated 24V power outputs: — 1.25 A. — 0.50 A. • Non-resettable 5V power: 0.15 A. • Battery charger range: 18 AH — 200 AH. Use separate cabinet for batteries over 26 AH. • Float rate: 27.6 V. CABINET SPECIFICATIONS • Systems can be installed in CAB-4 Series cabinets (four sizes with various door options, see DN-6857). Requires BP2-4 Bat- tery Plate. SHIPPING WEIGHT • CPU2-640/-640: 14.3 lb (6.49 kg). • CPU2-640/-640E: 14.55 lb (6.60 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 — 49°C/ 32 — 120°F and at a relative humidity 93% t 2% RH (noncondens- ing) at 32°C t 2°C (90°F t 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80° F. AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic NFS2-640 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listed: S635. • ULC Listed: S527-11 • FM Approved. • MEA:128-07-E. • Fire Dept. of New York: #6212. • CSFM:7165-0028:0243. • City of Chicago. • City and County of Denver. • CCCF listed. Marine Applications: Marine approved systems must be config- ured using components itemized in this document. (See Main Sys- tem Components, in "Product Line Information.) Specific connections and requirements for those components are described in the installation document, PN 54756. V**A these requirements are followed, systems gre approved bJ#*Jdl'owing agencies: • • • • • 0 • US Coast Guard 161.002/50/0, 161.002/55/0 %t§64?d 46 CFR and 161.002). "';" • • Lloyd's Register 11/600013 (EN113 cafegory). • American Bureau of Shipping Approval � � • NOTE. For information on marine appi,06ans, see DAY 93688. STANDARDS • • " " % The NFS2-640 complies with the rollowin� UL Standaids and NFPA 72, International Building CodC jIBCl .and California Build- ing Code (CBC) Fire Alarm Systems frequiretRents: ; • •;, • UL 864, 9th Edition (Fire). • • ' • UL 1076 (Burglary). • • • ' • UL 2572 (Mass Notification Systems). (NFS2-640 vtsr>li8R20 or higher.) • ULC-S527-11 Standard for the Installation of Fire Alarm Sys- tems. • LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). • AUXILIARY (Automatic, Manual and Waterflow) (requires TM- 4). • REMOTE STATION (Automatic, Manual, Waterflow and Sprin- kler Supervisory) (requires TM-4). • PROPRIETARY (Automatic, Manual and Waterflow). Not applicable for FM. • EMERGENCY VOICE/ALARM. • OT, PSDN (Other Technologies, Packet -switched Data Net- work). • IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). • CBC 2007 (Seismic). IntelliQuadTMNOTI•FIRE•NETT"' ONYXWork$TM, and SWIFTTm are trademarks; and ACelimate® PIUSTM FirstCommandO, FlashSCen®, Intelligent FAAST®, NOTIFIER® ONYX®, VeriFirO Tools, and VIEW" are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. IBM® is a registered trademark of IBM Corporation. 02017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ' O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINFERINC A MANUFACTIRINC QUALITY SYSTEMS All specifications are subject to change without notice. Country of origin: USA For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 8 of 6 — DN-7111:M • 3/24/17 DN-6933:D • E-205 BAT Series Batteries Sealed Lead -Acid General BAT Series Batteries are Power -Sonic brand batteries. BAT Series (or Power -Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features • Provide secondary power for control panels. • Sealed and maintenance -free. • Overcharge protected. • Easy handling with leak -proof construction. • Ruggedly constructed, high -impact case (ABS). • Long service life. • Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batter- ies. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Recognized Components: MH2O845 (Power -Sonic) Part Number Reference & Specifications NOTIFIER° by Honeywell •••••• 69133`p pg•�.. Ordering Information • • •000.0 BAT-1250-BP: 10-unit bulk pack ofJW*14260 (12 V 5 AH). BAT-1270-BP: 5-unit bulk pack of BPFf-1.2'70 (12 V7 AH). BAT 12120-BP: 4-unit bulk pack of:lAi.1M20 (12V 12 AH). BAT-12180-BP: 2-unit bulk pack of BAT-1 J180 (12;.V 18 BAT-12260-BP: 2-unit bulk pack of W12Q60 (12•V 26 AH). BAT 12550: single battery (12 V 55 AH). • • • • BAT 121000: single battery (12 V 100 AH). Battery Description DIMENSIONS Part Power - Nominal Width Depth Height Height over Weight Number Sonic Part Number Nominal Capacity terminal Voltage V @ 20 hr. in. mm in, mm in. mm in. mm lb. kg. rate A.H. BAT-1250 PS-1250 12 5 sealed 3.54 90 2.76 70 3.98 101 4.21 107 3.50 1.59 BAT-1270 PS-1270 12 7 sealed 5.95 151 2.56 65 3.7 94 3.86 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 5.95 151 3.86 98 3.7 94 3.94 100 7.92 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 3.00 76 6.59 167 6.59 167 12.6 5.72 BAT-12260 PS-12260 12 26 sealed 6.5 167 6.97 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-12550 12 55 sealed 9.04 230 5.45 138 8.15 207 8.98 228 36 16.33 BAT 121000 PS-121000 12 100 sealed 12 305 6.6 1168 8.15 207 8.98 228 68 30.84 DN-69330 • 02/28/2013 - Page 1 of 2 Discharge Characteristic Curves at 200C (680F) For 6V For 12V Battery Battery 6.6 13.0 e 6.0 12.0 0q0 5.5 11.0 0.10C- 0_05C. 0-20C C 5.0 10.0 0 600.40C C - E t 4.5 �— 9.0 4.0 r 8.0 100 0 0 W 80 c 0 60 m u 40 a 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 -.— Minutes et Hours Discharge Time PS-121000 Shelf -Life and Storage 1\aa '••.■■■■■Charging is not tt 16IN 0 a 0"M 0 ■"„■■■Charging before help recover ■,"',■■to Charge may fail to restore full capacity. Do not let batteries rest U 0 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) PS-121000 Discharge Characteristics 14.0 13.0 � 12.0 m p 11.0 m � 10.0 E d � 9.0 8.0 1.2 2.4 6 12 24 36 481 2 4 6 810 20 40 W I. m n 1h 1 Discharge Time HE ON@ 113,MINIMUM1 1111101111111 1 ON . r ti ■1'I■1 ■01' i i .,1■-„1.,�'�. Effect of Temperature on Capacity 120 110 e 80 60 40 20 0 0.05 C 0.10 c 0.25 C 0.50 C i[O -40 -30 -20 .10 0 10 20 30 40 50 60 Temperature (°C) e • • • • • • • • • • • • • • • • .... .... . . .... .... ..... • • •••••• • • • • • • • • • •e•e NOTIFIER® is a registered trademark of Honeywell International Inc. Batteries display trademarks of the manufacturer. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6933:13 • 02/28/2013 DN-6927:A2 FCPS-24S6(C/E) & FCPS- 2458(C/E) 6- & 8-Amp 24-Volt Remote Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 2458 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS-24S6/-2458 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C & FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 2456 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features • UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. • Operates as a "sync -follower" or as a "sync -generator" (default). See note on page 2. • Contains two fully -isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous output in stand-alone mode (UL 1481). • Compatible with coded inputs; signals passed through. • Optional power -supervision relay (EOLR-1). • In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. • Fully regulated and filtered power output - optimal for pow- ering four -wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. • Power -limiting technology meets UL power -limiting require- ments. • Form-C normally -closed trouble relay. • Fully supervised power supply, battery, and NACs. • Selectable earth fault detection. • AC trouble report selectable for immediate 2-hour delay. • Works with virtually any UL 864 fire alarm control which uti- lizes an industry -standard reverse -polarity notification cir- cuit (including unfiltered and unregulated NAC power). • Requires input trigger voltage of 9 - 32 VDC. • Self-contained in compact, locking cabinet - 15"H x 14.5"W x 2.75'D (cm: 38.1 H x 36.83W x 6.985D). (�J NOT 1 F 1 E R° by Honeywell • • Includes integral battery charger capable of charg ng up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp -type terminal blocks accommodate up to 12 AWG (3.1 mm2) wire. Specifications Primary (AC) Power: • FCPS-24S6C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum. • FCPS-24S6E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum. • Wire Size: minimum #14 AWG (2.Omm2) with 600 V insula- tion. Control Input Circuit: • Trigger Input Voltage: 9 to 32 VDC. • Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: • +24 VDC filtered, regulated. • 3.0 A maximum for any one circuit. • Total continuous current for all outputs (stand-alone mode): — FCPS-24S6: 4.0 A maximum. — FCPS-24S8: 6.0 A maximum. • Total short-term current for all outputs (NAC expander mode): — FCPS-24S6: 6.0 A maximum. — FCPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: • Supports lead -acid batteries only. DN-6927:A2.5/17/13 — Page 1 of 2 Float -charge voltage: 27.6 VDC. Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse -polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24S6/-24S8 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24S6/-24S8 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24S6/-24S8 are configured (via DIP switch settings) as a "sync generator;' the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24S6 and FCPS-24S8 comply with the following standards: • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). • UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635, S674 •... • ULC Listed: S635 (FCPS-24S6� & FCPS-24A" • • • • CSFM Approved: 7315-0028:221. • • MEA: 299-02-E •.•••. �••�++ • FM Approved •.•+•• • Ordering Information be** • • • • FCPS-24S6: 6.0 A, 120 VAC remA:1IT4ger pc:wdEatpply. Includes main printed circuit board!trar%formers! enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 Fix 96.68W x 6.98513]), and installation instructions. FCPS-24S6C: Same as above, ULri-listed. • FCPS-24S6R: Same as FCPS-24S6Vith rtd enclosure. • •••• FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-24S8 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end -of -line relay for monitoring four -wire smoke detector power. BAT 1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). System Sensor® and NOTIFIER& are registered trademarks of Honeywell International Inc. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 'SO 9oo1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENBINEUIIN6 A MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6927:A2.5/17/13 DN-6935:E • H-202 FSP-851(A) Series Intelligent Plug -In Photoelectric Smoke Detectors with FlashScan@ General Notifier FSP-851(A) Series intelligent plug-in smoke detec- tors with integral communication provide features that sur- pass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is con- tinuously monitored and reported to the panel. Point ID capa- bility allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851(A) photoelec- tric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed - temperature thermal sensing on the FSP-851T(A). The FSP- 851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851(A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan@ (U.S. Patent 5,539,389) is a communication protocol developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features • Sleek, low -profile design. • Addressable -analog communication. • Stable communication technique with noise immunity. • Low standby current. • Two -wire SLC connection. • Compatible with FlashScan@ and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Optional remote, single -gang LED accessory. • Dual LED design provides 360' viewing angle. • Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashS- can systems only). • Remote test feature from the panel. • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(FlashScan systems only). • Built-in functional test switch activated by external magnet. • Built-in tamper -resistant feature. • Sealed against back pressure. • Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appear- ance. • 94-5V plastic flammability rating. • SEMS screws for wiring of the separate base. • Optional relay, isolator, and sounder bases. �J NOTIFIER° by Honeywell •••• ---moo FSP-851(A) in B210kPfA) Base ••" •••••• • • • •••••• Specifications 000000 • : i•••:• Sensitivity: 0.5% to 2.35% per foci obswration • Size: 2.1 " (5.3 cm) high; base deterr'h es;iamet:r. • � � • ••• — B210LP(A): 6.1" (15.5 cm) diameter. — B501(A): 4.1" (10.4 cm) diameter. — 6200S(A): 6.875" (17.46 cm) diameter. — B200SR(A): 6.875" (17.46 cm) diameter. — B224RB(A): 6.2" (15.748 cm) diameter. — B224BI(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.2oz. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F). Low temperature signal for FSP-851T(A) at 45°F +/- 10°F (7.22°C +/- 5.54°C). FSP-851 R(A) installed in a DNR(A)/ DNRW, -20°C to 70°C (-4°F to 158°F). UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed -temperature setpoint 135°F (57°C) DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, docu- ment A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one com- munication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC ("ON"). DN-6935:E • 2/11/2015 — Page 1 of 2 Installation FSP-851(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors with- out using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junc- tion boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class `B') wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applica- tions may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S1115. • ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP- 851 TA). • MEA Listed: 225-02-E . • FM Approved. • CSFM:7272-0028:0206. • Maryland State Fire Marshal: Permit # 2122 . • BSMI: C1313066760036. • CCCF: Certif. # 2004081801000017 (FSP-851T) Certif. # 2004081801000016 (FSP-851). • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/ 0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). • Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: 'A" suffix indicates ULC Listed model. FSP-851: Low -profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP-851A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135'F (57°C) fixed -temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851R: Low -profile intelligent photoelectric sensor, remote test capable. For use with DNRA/DNRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: `A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low -profile mounting base. B21OLPBP: Bulk pack of B21 OLP; package contains 10 B501(A): Standard European flangeless mounting base B501 BP: Bulk pack of B501; package contains 10. B20OS(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw ter- minals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Plug-in System Sensor isolator detet" base. Maximum 25 devices between isdator (vases. • • • • Soso:* ACCESSORIES • •••••• •• F110: Retrofit flange to convert B24OLP(A) to match the B71 OLP(A) profile, or to convert oider•[Tigh-profile bases to low -profile. : :*see: 0""0 .""• F110BP: Bulk pack of F110; pac l�agg�pgtains 1r5. • ••; �' F210: Replacement flange for 1324GIN(,Af base. • • • • • • • • RA10OZ(A): Remote LED annunJiAfbt'::— 32 VDC*Mounts •. to a U.S. single -gang electrical box. Fot use %Vi" P5Q1(A) and B21OLP(A) bases only. • • • • ' SMB600: Surface mounting kit *ego •••• M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR26: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-20OB: Black detector covers for use with FSP-851(A) only; box of 10. WCK-20OB: White detector covers for use with FSP-851(A) only; box of 10. NOTIFIERO is a registered trademark of Honeywell International Inc. 02015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 'SO 9oo1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINE31NI INUII IACTIIINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6935:E • 2/11 /2015 ^'h NOT 1 F 1 E R° by Honeywell Intelligent Bases Standard, Relay, Isolator, Sounder, and Low -Frequency Sounder Bases General To meet local code and application requirements, NOTIFIER® offers standard 4" and 6" bases, as well as, specialty base designs includ- ing relay, isolator, sounder and low frequency sounder options for the new 900 Series of addressable detectors as well as previous generations. The standard 4" and 6" bases offer a plug-in detector base intended for use in intelligent systems, with screw terminals identified with a (+ and —). The 4" base offers a compact design while the 6" base provides compatibility with a wider range of junction boxes. The specialty bases support application driven requirements. These bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface -mount boxes. The mounting plate enables pre -wiring of all connections to speed and simplify installation. Relay bases provide one form-C contact relay for control of auxiliary functions, such as door closure and elevator recall. The relay can operate in two different modes (short and long delay). The activation time for the short delay is 60-100 milliseconds, while the activation time for the long delay is 6-10 seconds. A shunt with pin headers, located on the base PC board, is used to set the delay timing. Isolator bases allow the Signaling Line Circuit (SLC) loop to operate under fault conditions created from a short circuit preventing an entire communication loop from being disabled. The base isolates the section of the loop containing the short circuit from the remain- der of the circuit and automatically restores when the fault is cor- rected. Sounder and low frequency sounder bases are designed for new and existing dwelling unit applications. They offer maximum flexibil- ity in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The low frequency sounder bases are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent. Studies show that a lower frequency, cen- tered around 520 Hz, is the most ideal to wake sleeping occupants, even those with mild to severe hearing loss. The B200SR sounder and -LF sounder bases (B200SR-WH/ B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501 BH Series sounder base installations. The device enables users to select one of two B501-supported tones (ANSI Temporal 3 or Continuous) through a jumper. The B200S sounder and -LF sounder bases (B200S-WH/B200S-IV/ B200S-LF-WH/B200S-LF-IV) adopt the same address as the detec- tor, but use a unique device type on the loop. The Fire Alarm Control Panel (FACP) can use that address to command an individual sounder — or a group of sounders — to activate. The command set from the FACP can be tailored to multiple event -driven tone outputs allowing selection of volume (75 or 85 dBA), tone (ANSI Temporal 3, ANSI Temporal 4, or March Time) and group. In addition, some FACPs will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables them to be used as a component of the general evacuation signal — along with other System Sensor AV appliances — when connected to a power supply or FACP output capable of generating the System Sensor synchronization pulses. B300-6 Standard • • B200S-WI-1' • • • SoAer Base {Wh i! e 6" Base (White) • B501-WHITE Flangeless B501-BL FlartgP"s 4" Base (White) 4" Base (Black) Specifications NOTE: Specifications applies to all model variants A "-BL", "-LF'; "IV -WH, -WHITE. See Product Line Information for detailed model descrip- tion. Diameter • B501-WHITE: 4" (10.16 cm) diameter. • B300-6: 6.1" (15.49 cm) diameter. • B224B1, B224RB: 6.2" (15.748 cm) diameter. • B200S, B200SR, B200SCOA: 6.875" (17.46 cm) diameter. Wire gauge: • B224B1, B224RB: 14 to 24AWG. • B300-6, B210LP, B501, B200S, B200SR, B200SCOA: 12 to 24 AWG Temperature range: • B224B1, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F (0°C to 49°C). • B300-6, B210LP, B501: -4°F to 150°F (-20oC to 66°C). Humidity range: 10% to 93% RH, non -condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F)- and at a relative humidity (non -condensing) of 85% at 30oC (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1 °F) per ULC. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). DN-60054:K • 7/18/2018 — Page 1 of 3 Electrical Ratings FOR B300-6 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 170 pA maximum FOR B501 SERIES BASES: Operating voltage: 15 to 32 VDC Standby current: 150 pA maximum FOR B200 SERIES BASES: External supply voltage: 16 to 33 VDC (FWR) Standby current: 500 pA maximum. Alarm current: • B200S(A)(-IV)(-WH) — 35 mA maximum at high -volume setting — 15 mA maximum at low -volume setting • B200S-LF(-IV)(-WH) High -volume setting: — 70 mA maximum @ 33.0 VDC — 90 mA maximum @ 24.0 VDC — 140 mA maximum @16.0 VDC • B200S-LF(-IV)(-WH) Low -volume setting: — 15 mA maximum @ 33.0 VDC — 20 mA maximum @ 24.0 VDC — 25 mA maximum @ 16.0 VDC • B200SR(A)(-IV)(-WH) — 35 mA maximum • B200SR-LF(-IV)(-WH) — 65 mA maximum @ 33.0 VDC — 90 mA maximum @ 24.0 VDC — 125 mA maximum @16.0 VDC • B200SCOA(-IV)(-WH) — 40mA Max (DC) — 70mA Max (FWR) SLC operating voltage: 15 to 32 VDC SLC standby current: See applicable sensor specification. Sound output: • B200S(A)(-LF)(-IV)(-WH), high -volume*: Greater than 85 dBA minimum. • B200S(A)(-LF)(-IV)(-WH), low -volume*: Greater than 75 dBA minimum. • B200SR(A)(-LF)(-IV)(-WH)*: Greater than 85 dBA minimum. • B200SCOA(-IV)(-WH), high -volume**: Greater than 87 dBA mini- mum. • B200SCOA(-IV)(-WH), low -volume**: Greater than 85 dBA mini- mum *Measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) **Measured in a ULC anechoic room at 10 feet, 24 Volts continuous tone) FOR B224BI, B224RB (A) (-III (-WH): Operating voltage: 15 to 32 VDC (powered by SLC) Standby ratings: <450 pA maximum @ 24 VDC Set time (B224RB(A)(-IV)(-WH) only): short delay 60-100 millisec- onds; long delay 6-10 seconds Reset time (B224RB(A)(-IV)(-WH) only): 20 milliseconds maximum Relay characteristics (B224RB(A)(-IV)(-WH) only): two -coil latch- ing relay, one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A @ 30 VDC Page 2 of 3 — DN-60054: K • 7/18/2018 Product Line Information INTELLIGENT BASES NOTE: "A"suffix indicates ULC Listed model. NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: "-WH" and `-WHITE" suffix indicates White color model. B21OLP: Flanged mounted base. B21OLPA: Same as 62101-P: ULC listed. B21 OLPBP: Bulk pack of B210LP, contains 10. 6300-6: White, 6" base, standard flanged low -profile mounting base. B300A-6: Same as B300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10;. B300-6-IV: Ivory,6" base, standard flanged low-pjgfi�% mounting base. • • B30OA-6-IV: Ivory, 6" standard flarR"lout-profile p�pupting base, .' ULC listed. • .•.•.. .. . ...... B501-WHITE: White, 4" standard "G*pan flangelev mounting • base. UL/ULC listed. 0000 • • •"' B501-WHITE-BP: Bulk pack of 1350T-YWITE contan6.10•' •. • •. B501-BL: Black, 4" standard European flemgelessa m o urring basis! • • • UL/ULC listed. .. • • • • • • • • • B501-IV: Ivory color, 4" standard Eeintjn flangeles% mounting '• base. UL/ULC listed. : • • • •...•. B224RB-WH: White, relay base. • • ' ' ' B224RB-IV: Ivory, relay base. " ' : • • • • • B224RBA-WH: White, relay base, ULC listed. B224RBA-IV: Ivory, relay base, ULC listed. B224BI-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224BIA-WH: White, isolator detector base, ULC listed. B224BIA-IV: Ivory isolator detector base, ULC listed. B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan® protocol. B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan® protocol. B200SA-WH: Same as B200S-WH, ULC listed. B200SA-IV: Same as B200S-IV, ULC listed. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA4V: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH, ULC listed. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listed. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A), B300(A)-6 bases. TR300-IV: Ivory, replacement flange for B210LP(A), B300(A)-6-IV bases. RA10OZ(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B300(A)- 6. Junction Box Selection Guide M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: White, detector color kit. Pack of 10. CK300-IR: White, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-IR-IV: Ivory, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10. CK300-IR-BL: Black, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications i `htf De, listed by certain approval agencies, or listing may be in procee�.4onsult fae• • • • • tory for latest listing status. '..' : • • • • • • . • • ULIULC Listed: S1115 •••••• •• • •••"• • • FM Approved 000000 ' ' ' 00000 • CSFM: 7300-1653:0109, 7300,jT65 '4126, ;IV-TV3:0213, ' 7300-1653:0236 0000 0000 00006,9 • 00 •• •• • •••••• • • • • • • . •••.•• • • • • • • •• • •• 0 • ' ' - Base Models Single Gang Double Gang 3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring B200S,B200SR, B200SCOA Yes Yes Yes Yes Yes Yes No No No No B501 No No Yes No No Yes Yes Yes Yes No B21OLP, B300-6 Yes No Yes Yes Yes Yes No No No No B224BI, B224RB Yes Yes Yes Yes Yes Yes No No No No NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE: Applies to all model variants 'A", "-BL", "-LF", "-IV', "-WH", and" -WHITE". See Product Line Information for detailed model description. '® eusinll E MFIYUFACTYM� QAALIT Y SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER FlashScanO, NOTIFIERO and System Sensor® are regis- 12 Clintonville Road tered trademarks of Honeywell International Inc. 4Northford, CT 06472 02018 by Honeywell International Inc. All rights reserved. NOT 1 F 1 E R 203.484.7161 Unauthorized use of this document is strictly prohibited. U\/ Honeywell www.notifier.com Country of Origin Mexico 7 DN-6726:D • H-240 NBG-12LX Addressable Manual Pull Station The Notifier NBG-12LX is a state-of-the-art, dual -action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire -ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-1/0) or semi - flush mounted. Semi -flush mount to a standard single - gang, double -gang, or 4" (10.16 cm) square electrical box. • Smooth dual -action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScanO pro- tocol loops. • Dual -color LED blinks green to indicate normal on FlashScanO systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 VDC. • Maximum SLC standby current: 375 NA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location 0 NOTIFIER 9 Intelligent/Addressable Devices The NBG-'C2LX ; • • Addressable Manual Pull Station Installation • The NBG-12LX will mount semi -flush into a single -gang, dou- ble -gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-1/0 sur- face backbox. If the NBG-12LX is being semi -flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi -flush mounting with 4" (10.16 cm) or double -gang boxes (not with single -gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 — 159 on FlashScan® systems, 1 — 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non -coded, with a key - operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red -colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi -flush mounting on a standard single -gang, double -gang, or DN-6726:D • 4/13/2012 — Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual -action addressable pull station. Includes key locking feature. (Listed for Canadian and non -Canadian appli- cations.) **Goo" NBG-12LXSP: Spanish/English labelled version. ' ' . Y • Y Y Y "• • NBG-12LXP: Portuguese labelled version. . • Y �. • SB-10: Surface backbox; metal. • SB-1/0: Surface backbox; plastic. • • • Y • • • • • BG12TR: Optional trim ring. • • • • • • • • "•' • 17021: Keys, set of two. "; "; ; • • • : • • NY -Plate: New York City trim plate. • Agency Listings and Approvals • In some cases, certain modules or applications may not be .. . • •. . • listed by certain approval agencies, or listing may be in pro- 'Y;•.' cess. Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non -Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0028:0199, • FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). • BSMI: C1313066760047. • U.S. Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERO and FlashScanO are registered trademarks of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEEIINC 8MMIFACTIMNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6726:D • 4/13/2012 DN-6643:A1 • 1-410 NBG-12 Series Non -Coded Conventional Manual Fire Alarm Pull Stations General The NOTIFIER NBG-12 Series is a cost-effective, feature - packed series of non -coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end -user in mind. The NBG-12 Series features a variety of mod- els including single- and dual -action versions. The NBG-12 Series provides an alarm initiating input signal to conventional fire alarm control panels (FACPs) such as the SFP Series, and to XP Transponders. Its innovative design, durable construction, and multiple mounting options make the NBG-12 Series simple to install, maintain, and operate. Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull -force. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated (single- or dual -action, model dependent), yet designed to prevent false alarms when bumped, shaken, or jarred. • PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. • The word "ACTIVATED" appears on top of the handle in bright yellow, further indicating operation of the station. • Operation handle features white arrows showing basic opera- tion direction for non -English-speaking persons. • Braille text included on finger -hold area of operation handle and across top of handle. • Multiple hex- and key -lock models available. • U.S. patented hex -lock needs only a quarter -turn to lock/ unlock. • Station can be opened for inspection and maintenance with- out initiating an alarm. • Product ID label viewable by simply opening the cover; label is made of a durable long -life material. • The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). • Four -position terminal strip molded into backplate. • Terminal strip includes Phillips combination -head captive 8/32 screws for easy connection to Initiating Device Circuit (IDC). • Terminal screws backed -out at factory and shipped ready to accept field wiring (up to 12 AWG/3.1 mm2). • Terminal numbers are molded into the backplate, eliminating the need for labels. • Switch contacts are normally open. • Can be surface -mounted (with SB-10 or SS-1/0) or semi - flush mounted. Semi -flush mount to a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box. • Backplate is large enough to overlap a single -gang backbox cutout by 1/2" (1.27 cm). • Optional trim ring (BG12TR). • Spanish versions (FUEGO) available (NBG-12LSP, NBG-12LPSP). • Designed to replace the legacy NBG-10 Series. • Models packaged in attractive, clear plastic (PVC), clam - shell -style, Point -of -Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. �J NOTIFIER° by Honeywell •• • • *6"cov.1P9 •••••• • • Construction •••••• • Cover, backplate and operation: handle are aM molVid of durable polycarbonate material.. • : • • • • Cover features white lettering and Ire. ; • • • • Red color matches System Sensor's popular tpLOertO Advance horn/strobe series. Operation The NBG-12 manual pull stations provide a textured finger -hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the sta- tion, provided for non -English-speaking people. Pushing in and then pulling down on the handle activates the normally -open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key or hex (model dependent), twist one quarter -turn, then open the station's front cover, causing the spring -loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non -alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. Specifications PHYSICAL SPECIFICATIONS: pull station SB-10 SB-1/0 WBB WP-10 H 5.500 in. 5.500 in. 5.601 in. 4.25 in. 6.000 in. (13.97 cm) (13.97 cm) (14.23 cm) (10.79 cm) (15.24 cm) W 4.121 in. 4.125 in. 4.222 in. 4.25 in. 4.690 in. (10.467 cm) (10,478 cm) (10.72 cm) (10.79 cm) (11.913 cm) D 1.390 in. 1.375 in. 1.439 in. 1.75 in. 2.000 in. (3.531 cm) 1 (3.493 cm) 1 (3.66 cm) 1 (4.445 cm) (5.08 cm) 6643di 2.tb1 ELECTRICAL SPECIFICATIONS: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or VDC. Auxiliary contact circuit (Terminals 3 & 4, NBG-12LA): rated to 3.0 A @ 30 VAC or VDC. DN-6643:A1 •04/22/08 — Page 1 of 2 ENGINEERING/ARCHITECTURAL SPECIFICATIONS Manual Fire Alarm Stations shall be non -code, with a key- or hex -operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger." Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-1/0; or semi -flush mounting on a standard single -gang, double -gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per nationalAocal requirements. Manual Stations shall be Under- writers Laboratories listed. NOTE. 'The words F/RE/FUEGO" on the NBG-12LSP and NBG- 12LPSP shall appear on the front of the station in white letters, approximately 314" (1.905 cm) high. Pre -Signal Models The NBG-12LPS and NBG-12LPSP pull stations are non -coded manual pull stations which provide a FACP with two normally open alarm initiating input signals. "Pre -signal" input is activated by pushing in, then pulling down, the dual -action handle. A "gen- eral" alarm input signal can be manually activated via a momen- tary rocker switch mounted inside the unit. This general alarm switch can only be accessed by opening the cover with the sup- plied keyAock. See diagram at right. Agency Listings and Approvals The listings and approvals below apply to the NBG-12 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • C(UL)US Listed: file S692. • CSFM approved: file 7150-0028:199. • FM approved (exceptNBG-12LPS, NBG-12LPSP). • MEA approved: file 67-02-E (NBG-12, NBG-12L, NBG-12LOB, NBG-12LA). • Lloyd's Register type approved: file 93/60141 (E3) (NBG-12, NBG-12L, NBG-12LA, NBG-12LOB, NBG-12S). • U.S. Coast Guard approved: files 161.002/23/3 (AFP-200 with NBG-12, NBG-12L, NBG-12S); 161.002/42/1 (NFS-640 with NBG-12, NBG-12L, NBG-12S); 161.002/27/3 (AFP 10101 AM2020 with NBG-12, NBG-12L, NBG-12S). • Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Product Line Information NBG-12S: Single-action pull station with pigtail connections, hex lock. NBG-12: Dual -action pull station with SPST N/O switch, screw terminal connections, hex lock. NBG-12L: Dual -action pull station with SPST N/O switch, screw terminal connections, key lock. NBG-12LSP: Same as NBG-12L with English/Spanish (FIRE/ FUEGO) labeling. NBG-12LPS: Dual -action pull station with pre -signal option. NBG-12LPSP: Same as NBG-12LPS with English/Spanish (FIRE/FUEGO) labeling. NBG-12LOB: Dual -action pull station with key lock, outdoor applications listings (NBG-121-0), and backbox. Includes SB-UO indoor/outdoor backbox, and sealing gasket. Model will also mount to WP-10 weatherproof backbox in retrofit applications. NOTE. NBG-12LO not available separately, NBG-12LO + approved backbox = NBG-12LOB. Outdoor applications listings apply to NBG-12LOB combination. NBG-12LA: Dual -action pull station with key lock and annuncia- tor contacts. SB-10: Surface -mount backbox, metal. SB-1/0: Surface -mount backbox, plastic. (Included with NBG- 12LOB.) • • • • BG12TR: Optional trim ring for seeii-flkis?tsrnounting.• • • • • • • • WP-10: Outdoor use backbox. • • • 0 • • 0 • • 17021: Keys, set of two. (Included WRM :@�Alock pull statibns.) • • • • • • 17007: Hex key, 9/64". (Included wfth t1AL?bck pull stations.) • • NOTE. For addressable NBG-120f •nledels, see • date •sheet • • DN-6726. •••• •••• ••w•• 1.3901, (3.531) ...... • •• •• Dime n lions . . ..... • •••••• • •••••• • • • Wire Length Strip Gauge • • • • • • • • • • • • • • • • • • sees 1.000" 0.750' (1.905) 5.500" (13.970) (cm) I— NBG-12LPS PRODUCT IDENTIFICATION LABEL ROCKER MPS TOGGLE SWITCH ® NOR SWITCH for General for Pre -Signal Alarm function notification A�rlvgrEo E NOTIFIERO, SpectrAlert® Advance, and System Sensor(D are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I O �oo This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6643:A1 •04/22/08 DN-6720:E FMM-1(A), FMM-101(A), FZM-1(A) & FDM-1(A) Monitor Modules with FlashScan@ General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry -contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two -wire smoke detectors (FZM-1(A)). FMM-1(A) is a standard -sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry -contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry -contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single -gang box behind the device it monitors. FZM-1(A) is a standard -sized module that monitors and supervises compatible two -wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard -sized dual monitor module that mon- itors and supervises two independent two -wire Style B (Class B) dry -contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two -wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM-1(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry of address: 01 — 159 on FlashScan loops; 01 — 99 on CLIP loops. • LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two -wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two -wire or four -wire fault -tolerant Initiating Device Circuit (IDC) for normally -open -contact fire alarm and supervisory devices. The module has a panel -controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- (�J NOT 1 F 1 E R° by Honeywell •••• FMM-1(A) (Type H) open dry -contact alarm activation devices. May also be used to monitor normally -open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E • 07/30/2015 — Page 1 of 4 FMM-101(A) Mini Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). • Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. device as a monitor module to the anel P • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. • Direct -dial entry of address: 01 — 159 on FlashScan loops; 01 — 99 on CLIP loops. 1415 0 1 ADDRESS 0 1 13��2 2 3 11 4 LOOP O 4 109�5 L-1 9 8 7 65 TENS ONES 0 J O U KZ m The FMM-101(A) Mini Monitor Module can be installed in a single -gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two -wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two -wire initiating device circuit for normally -open -contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally -open dry -contact devices. May also be used to monitor normally -open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 471k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Page 2 of 4 — DN-6720:E • 07/30/2015 Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZMA (A) Interface Module • Supports compatible two -wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. .... • SEMS screws with clamping plates for ease of "r" • Direct -dial entry entry of addresg:•01 • 159 op"11%Scan loops, 01 — 99 on CLIP loops. • • • e • • • • • • LED flashes during normal op'1la'tlbh'this is a fltogram- mable option. 000000 000000 • LED latches steady to indicate •a1?rM on comMJM from control panel. ••;••; 0•••0• The FZM-1(A) Interface Module A IntAked for tse in intelli- gent, addressable systems, wheVt?i:1Jdividual address of each module is selected using built-in rotary sv� iit mew � This module allows intelligent panels to interface and monitor two - wire conventional smoke detectors. it Lnsmits the.status (normal, open, or alarm) of one full zone of %OWAional detectors back to the control panel. All two -wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two -wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End -of -Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T10 and T11): • DC voltage: 24 volts power limited. • Ripple voltage: 0.1 Vrms maximum. • Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two -wire systems. It provides two independent two -wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel - controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32' to 120°F (0' to 49°C). Humidity range: 10% to 93% (non -condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1(A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface -mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power -limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635. • ULC: S635. • FM Approved. • CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. • MEA:457-99-E. • U.S. Coast Guard: 161.002/50/0 (NFS2-640, N,Fa-320, NFS2-3030). • • • Lloyd's Register: 11/600013.WIFS2-640, WS.2-320, NFS2-3030). ' • Fire Dept. of New York: COA.A21 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030)..... . •.. Product Line InformativA.. . NOTE: A" suffix indicates ULC-listed 941/o/ • FMM-1(A): Monitor module. FMM-101(A): Monitor module, min iaturg . • • • • • FZM-1(A): Monitor module, two-wir&,Jetactors.. • • FDM-1(A): Monitor module, dual, two independetl "ass B circuits. SMB500: Optional surface -mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:E • 07/30/2015 — Page 3 of 4 . . .... ...... ...... .. . ...... .... .... . . .... .... ..... ...... . . ..... .. .. . ...... . . . . ...... FlashScan® and NOTIFIER® are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 1S0 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING U MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — DN-6720:E • 07/30/2015 DN-60429:C1 DNR(A)/DNRW InnovairFlex Intelligent Non -Relay Photoelectric Duct Smoke Detector General The Notifier InnovairFlex® DNR(A) intelligent non -relay photo- electric duct smoke detector and DNRW watertight non -relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20oC to 70oC), and a humidity range of 0 to 95 percent (non -condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Notifier InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Notifier InnovairFlex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair models, including remote test accessories. Features • Photoelectric, integrated low -flow technology. • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s). • Versatile mounting options: square or rectangular configu- ration. • Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non -condensing). • Patented sampling tube installs from front or back of the detector with no tools required. • Cover tamper signal. • Increased wiring space with a newly added 3/4" conduit knockout. • Available space within housing to accommodate mounting of a relay module. • Easily accessible code wheels on sensor head (sold sepa- rately). • Clear cover for convenient visual inspection. • Remote testing capability. • Requires corn line power only. • Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. �J NOTIFIER° by Honeywell Specifications • Size: (Rectangle) 14.38 in (37 &n) 6en,gth; 5'n (12.7 cm) Width, 2.5 in (6.6 cm) Depth. • • ' ; • • • Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9-crfi)_1 idth; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 158°F (-20oC to 70°C). Storage Temperature Range: -22°F to 158'F (-30°C to 70°C). Operating Humidity Range: 0% to 95% relative humidity (non -condensing). Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s). Accessories Notifier provides system flexibility with a variety of accessories, including two remote test stations and different means of visi- ble and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote -test -capable detector. ACCESSORY CURRENT LOADS AT 24 VDC Device Standby Alarm RA10OZ OmA 12 mA Max RTS151/ RTS151KEY OmA 12mA Max Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL: S911, S3705. • ULC: S635. DN-60429:C1 •4/19/2012 — Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information NOTE: `A suffix indicates ULC listed model. DNR(A): Intelligent non -relay photoelectric low flow smoke detector housing. Requires photoelectric smoke detector (sold separately). DNRW: Watertight intelligent non -relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). FSP-851R(A): Remote test capable addressable low -profile photoelectric smoke detector. FSP-851(A): Addressable low -profile photoelectric smoke detector. NP-100: Addressable low -profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low -profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft (0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTS151(A): Remote test station. RTS151 KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. • • • • • • • • • • • • • • • • • • • • • • • . • . . • • • • • • • • • • •• • • •• • • • • • Notifier@ and FlashScan® are a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 1S0 �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING U MANUFACTURING QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-60429 V • 4/19/2012 DF-60536:131 Duct Smoke Detector Accessories General Duct smoke detector accessories add functionality to the duct smoke system by allowing quick, convenient inspections at eye level and effective audible and visual notification options. All System Sensor duct smoke detectors and accessories are UL listed. Specifications APA151 PIEZO ANNUNCIATOR The APA151 piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. E E � � 3 a APA151 Piezo Annunciator Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 32°F to 120°F (0°C to 49°C) Relative Humidity 10 to 93%, non -condensing Wire Gauge 12 to 18 AWG Dimensions 4.6" H x 2.9" W x .45" D MHR/MHW MINI -HORNS The MHR and MHW SpectrAlert® Advance mini -horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single -gang back boxes for applications where a small device is desired. r E E ti (2) Flre•ure°warms by Honeywell MHR/MHW SpectrAlert Advance Mini -Horns Regulated 12 DC or FWR (Full Voltage Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC(9 to 33 VDC with Sync-CircuitTModule) 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 17.5 Sounder Current Draw Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 320F to 120OF (0°C to 49°C) Humidity Range 10 to 93% non -condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12 to 18 AWG Dimensions 4.6"H x 2.9"W x 0.45"D DF-60536:131 • 1 /27/12 — Page 1 of 4 RA100Z/RA100ZA REMO TE A NNUNCIA TORS The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. RA100ZIRA100ZA Remote Annunciator Conventional System: 3.1 to 32 Voltage Range VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 10 mA Dimensions 4.6"H x 2.8"W x 1.3"D RTS151IRTS151KEY REMOTE TEST STATIONS The RTS151 and RTS151 KEY remote test stations are auto- matic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151 KEY test station features a multi -colored LED that alter- nates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. RTS151 Remote Test Station Power Requirements Alarm LED 2.8 to 32 VDC, 10 mA max. Total Current: 95 mA max. Test Switch 10 VA @ 32 VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non -condensing Wire Gauge 14 to 18 AWG Dimensions 4.8"H x 2.9W x 1.4"D Page 2 of 4 — DF-60536:61 • 1 /27/12 RTS151 KEY Remote Test Station with Key Power Requirements Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (RED): 2.8 to 32 VDC, 12 mA max. Alarm Response Time 40 seconds max. Temperature Range 14°F to 140°F (-10°C to 60oC) Relative Humidity 95% non -condensing Wire Gauge 14 to 18 AWG Dimensions 4.6"H x 2.75W x 1.8"D RTS21RTS-AOS MULTI -SIGNALLING ACCESSORIES • . • .. • The RTS2 and RTS2-AOS multi *ignaliog accestsori*s are • designed to work with InnovairFlax, 4";p conv9iaW gr duct ; smoke detectors. These accessori�.% 4WD e a key swjtch that can be used to select one of two connected sensors to be :.•.•: tested, reset, or both by a push but0n sw'itsrh. They aisb'epable ' ' sensitivity measurements using tlfe*&ENS-RDR'%tMsitivity ••"•• reader (sold separately). The A08 *"tI-On Strobe# is an • • e • • optional accessory included with th* RY62!AOS model*' * • • • 0 * s SMOKE • • • • • •••••• • ' 3 of 0 a E a CO 0 a C0 rr RTS2 and RTS-AOS Multi -signaling Accessory Voltage 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without Strobe: 30 mA max. Alarm with Strobe: 55 mA max. Sounder 85 dBA at 10 ft. Temperature Range 14°F to 140°F (-10°C to 60°C) Relative Humidity 95% non -condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6"D Product Line Information APA151: Piezo Annunciator MHR: Mini -Horn, Red MHW: Mini -Horn, White RA100Z/RA100ZA: Remote Annunciator RTS151: Remote Test Station RTS151 KEY: Remote Test Station with Key RTS2: Multi -signaling Accessory AOS: Add -On Strobe RTS2-AOS: Multi -Signaling Accessory Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 320C ± 20C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 270C/60 — 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic products. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S4011 (APA 151, MHR, MHW), S2522 (RTS2, RA100Z, RTS151, RTS151KEY, RTS2-AOS) • FM Approved • CSFM: 7135-1653:0212 •rr• . . .... ...... • *feet* • • 90000 • • •••••• • 000009 • • • . ••.••• .• • • .• . •0000 DF-60536:B1 • 1/27/12 — Page 3 of 4 . . .... ...... f • • • ...... .. . ...... • •••• •••• • • • i • • Fire-Lite® Alarms and System Sensor@ are registered trademarks of Honeywell International Inc. 02012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ' O 9oo We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 — DF-60536:131 • 1 /27/12 itarLink- Commercial Fire Alarm Communicators: COMMERCIAL FIRE � Sole &Dual Path Cellular &/or IP • Universal full event sole path cellular & dual path cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere • For use as primary or backup communications on all 12V-24V control panels and FACPs that communicate using Contact ID and 4/2 (such as on legacy panels) • Reports to any Central Station nationwide, with your choice of cellular networks: Verizon Network Certified CDMA or GSM 3/4G on AT&T • Easy, flexible installation, activation & online account management • Cost -saving models and plans for any code requirement. Substantial savings over monthly dedicated landline charges. And, $100 saving incentive with any 2G Communicator upgrade (unlimited). LIL and NFPA 72 Fire Code -Compliant, the Starl-ink Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest coverage footprint available in Verizon Network Certified TM CDMA or GSM 3/4G models on the AT&T network, as well as mercantile models, all provide the most economical solution and for easy, versatile installation. Safeguard Accounts & Reliability. For applications currently relying upon quickly -disappearing traditional e"ma, lines, Starl-ink wireless communicators can•be used ferslarimary or...... backup communications, and wiN mot only safegWard the fire .' alarm reporting transmissions iior 0"future, but.pr0iide the....; end -user monthly savings for each cgstly FACP-di4dicated • landline they replace. And, for upgrading older vyi�pless firE:MM" communicators on 2G and other p�3s'ed-out'd�4Ll�r'network�,.Ill• Starl-ink Fire radios, offer a $1 Qa$-jdeup incentive�o help j efray. • the cost of the hardware replaGgr%gt`to the Pl 1*)tLhd state-o- the -art Starl-ink model of choi •: • Flexible Performance & Reparting Options. tars ink Fire....;. provides full data reporting, ins of eaard dual path, as a primary or . backup, to any central station of rour.choice�witbout requi� any special equipment on premises. Ultra-aflcir%419 plans are available to meet various codes and requirements, with supervisory check -ins from 200 seconds, to 5-minutes, to an hour. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www. 4N, napcocomnet.com. And, Starl-ink Fire Communicators are easily connected to any panel or Fire Alarm Control Panel (FACP) standardly operating between 12V and 24V. Flexible in any application, Starl-ink Fire also comes in standard, or Mercantile Models in metal housings, with code - compliant supervision, with or without using conduit; and choice of power options, powered by the panel or using its own 120V Power Supply. StarL.ink I compliant standard or mercantile metal models (right and left, respectively) . Napco StarLink3 Universal Fire Alarm Communicators • Sole Path Cellular and Dual Path Cellular &/or IP Money -saving 2G Tradeup incentive credit Models • Choice of plans (varies by model) - check -ins from 200 seconds, to 5-minutes to 1 hour, Verizon or AT&T • Patented Signal BoostTM signal amplification circuit and high -gain performance antenna for longer range and reliability nationwide • Bonus: Full High -Speed Napco Panel remote uploading/ downloading • COMPLIANCES: NFPA72 Editions: 2013, 2010, 2007; UL 864, 9th Ed., UL1610, UL985, UL1023, NYFD (as back-up); CSFM NETWORK —+ verlZQn CERTIFIED 0' Specifications • Durable ABS plastic housing includes three keyhole slots for mounting (for commercial application, aligns with triple gang boxes.) • Dimensions: 5-3/8"x 7-7/8"x 1-7/8" (HxWxD) • Weight: 13.5 oz • 3 LED Indicators - Green, Signal Strength; Amber- Busy/ Activation; Red -Trouble • Patented Signal BOostTl signal amplification circuit and high - gain performance antenna • Operating Environment: 0 to 49' C (32-120'F), up to 93% humidity (non -condensing) • 12V - 24V Universal FACP Support, auto -current sensing. Support all brands communicating in Contact ID and 4/2 • Powered by Panel, Low current draw, 71 mA standby, 200mA transmit MERCANTILE MODELS (similar to above, with): • Locking Metal Enclosure with Hinged door & 2 key -slots for wall mounting (LED indicators, inside). • Dimensions: 9-5/8"x 11-3/4" x 3-3/8"D (HxWxD) • Weight: 8 Ibs (max., power supply models) • Electrical Ratings for 120VAC, 60Hz • For Models with Power Supply: • Input Voltage: 120VAC Nominal Current: 400mA maximum • Maximum Charging Current: 200mA • Electrical Ratings for +12V • For Models without Power Supply: • Input Voltage: 11-15VDC (power -limited output from listed control panel) • Input Current: 71 mA with peak RF transmission current of 200mA. • Electrical Ratings for the IN 1 Burg/Fire Input: • Input Voltage: 9-15VDC • Maximum Input Current: Up to 2mA from FACP NAC circuit • Electrical Ratings for IN 2 and IN 3: • Maximum Loop Voltage: 15VDC • Maximum Loop Current: 1.2mA • Electrical Ratings for 3 PGM Outputs: • Open Collector Outputs: Maximum voltage 3V when active; 15V maximum when not active • Maximum PGM Sink Current: 50mA mount. • Operating Environment 0 to 490 C (32-120°F), up to 93% humidity (non -condensing) • 12V - 24V Universal FACP Support, auto -current sensing. Support all brands communicating in Contact ID and 4/2. 11 - -„ i Ordering Information COMMERCIAL FIRE SOLE PATH CELLULAR & DUAL PATH CELLULAR &/OR IP ("I" MODELS):' SLE-CDMA-FIRE Standard ABS (Red) Fire Sole Path Alarm Communicator, Cellular CDMA, Verizon-Network Certified SLE-CDMAI-FIRE as above, Dual Path Alarm Commi.6rycator, Cellular &/or IP (primary or backup, selectable) •....' ,,,,,, SLECDMA-CFB-PS Commercial Fire Nlerc'antile W-",�t.n red • metal housing, CDMA, Verizon-Ne M:k" Certified! Dirtct 120\AAG •: • Powered (w/ provisions for backul3 batty/charger)!Or, Optional • TRF20 plug-in transformer may bE�C!Jle"phere cad"permit • SLECDMA-CFB Commercial Fire Mercantile modei n'red metal" • • g =74ified P4"44 direct" • • • housing on CDMA, Verizon-Networ from control panel .. .. . ...... Note: Substitute prefix "SLE3/4G-"pn ahytnodets above for AT&T 314G Network 0 ... : • ...... ACCESSORIES: • • • SLE-DLEXT Optional, as above, for downloading, eectends distance to Napco panel up to 100' TRF20 Optional Plug in AC Transformer, 16.5V / 20VA (use is subject to local code compliance) SLE-DLCBL Optional High -Speed Napco Panel Up/download cable Also Available: StarLink Intrusion Radios in standard and mercantile versions SLE-GSM-3/4G Standard Burglary Radio (Black), GSM 3AG on AT&T Network powered by panel. SLE-CDMA as above, but CDMA communications, Verizon-Network Certified. SLECDMA-CB Commercial Burglary CDMA Radio, Verizon Certified, in white metal housing. Powered directly from control panel. SLE3/4G-CB as above, but GSM 3AG a on AT&T Network. ?emu` SLE3/4G-CB-TF Commercial Burglary — CDMA, Verizon Certified in white metal housing with power supply powered by plug-in 16.5V / 20VA transformer & provision for battery. n SNAGPLCSO 333 Bayview Ave., Amityville, NY 11701 USA 1-800-645-9445 • Fax:1-631-789-9292 www.napcosecurity.com E` \ NETWORK NFPX VerlZgn CERTIFIED COMPLIANCES: NFPA 72 Editions: 2013, 2010, 2007; UL 864, 9th Ed., UL1610, UL985, UL1023; NYFD (as back-up); CSFM *Starl-ink Fire are also rated to support Intrusion/Burglary alarm reports where applicable. StarLinkt- and Signal Boost are trademarks of NAPCO. Pats. Pending. Specifications subject to change. ©NAPCO, NAPCO Security Technologies Inc. (NASDAQ:NSSC) A676D 2016.5 * Verizon and Verizon Network Certified, UL, AT&T and other trademarks, are trademarks of their respective companies, and are unaffiliated with NAPCO. SYSTEM SENSOR'' Indoor Selectable - Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual -voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, 185 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (114, 112, 1 and 2 watts) • Seakers offer high fidelity and high volume sound output • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper -resistant construction • Updated modern aesthetics Agency Listings SIGNALING U` F M A?PROVED , LISTED S4048 FM approved except 7320-16530505 for ALERT models 3057493 The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre -wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field -selectable candela settings for wall speaker strobes. The low total harmonic distortion of the speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. System Sensor L-Series makes installation easy • Attach a universal mounting plate to a 4 x 4 x 2118 inch back box. Flush -mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21i8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•CircuitTM Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 320F and 120OF from a regulated DC, or full -wave rectified. unfiltered power supply. Wall - mount speaker strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, 185. Speaker The speaker shall be a System Sensor L-Series model dual -voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range pf'4'OfJTO. 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps $nd V%ge that ate Selected • • • • • • by rotary switches. • • • • • • • .' . • Speaker Strobe combination . • . ; .. The speaker strobe shall be a System Sensor L-Series model listed to 1480 and UL 1971 and be aW4(jved for fire pa;tive • • • • • • signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary s0i&V,4r1f shall Rave a • • frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the ": " • NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltag w ge the stro$o 494 Shall �r� consist of a xenon flash tube and associated lens/reflector system. • • • • • • Synchronization Module • • • • •..00 • The module shall be a System Sensor S nc•Circuit model MDL3 listed to UL 464 and shall be a � "' y y approved for fire �roteckve service. the module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21i8-inch back i module sfii;all a1V : • •' • control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining VJ .or I'hore synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Dimensions, Wall -Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm .97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPSL Speaker/Strobe (including lens and speaker) 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Back Box Electrical/Operating 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm Nominal Voltage (speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC or regulated 24 DC/FWR',2 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33V (24 V nominal) Frequency Range 400 to 4000 Hz Power Y4, 1/2, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd UL Current Draw Data -, 8 to 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 10' 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Output Speaker Strobe 1/aW 1/zW 1 W • 2W • •••• •.•..• UL Reverberant (dBA @10 ft) 77 80 83 • • 86 • • • • ' •' UL Anechoic (dBA @10 ft) 77 80 83 • • • 89 • • • . Sound Output ...... UL Reverberant (dBA @10 ft) 79 82 85 06168 • • • • • . • .. UL Anechoic (dBA @10 ft) 79 82 85 • • ; 468 : � • � � � • .:..' � • L-Series Dimensions 6 .97 1.63 63 6 2.30 1.39 Wall -Mount Speaker Wall -Mount Speaker Strobe 1.63 Surface Mountin Wall -Mount Speaker Strobe with SBBSPL Surface Mount Back Box L-Series Ordering Information . . .... ...... • • w • • • 00:06 • w White Red Description SPWL SPRL Speaker only SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT — Speaker Strobe, Amber Lens SPSWL-CLR-ALERT — Speaker Strobe Clear Lens — SPSRL-SP Speaker Strobe, Fuego White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPWL SBBSPWL Surface Mount Back Box for Speakers and Speaker Strobes TR-2W TR-2 Wall Mount Trim Ring Notes: All -P models have a plain housing (no "FIRE" marking on the cover) .SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 02017 System Sensor. 1 Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Vslt systemsensoccom A /SOR� for current product information, including the latest version of this data sheet. SE www.systemsensor.com AVDS86701 • 03/17 SYSTEM Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Field -selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Agency Listings SIGNALING & <FM> MEA LISTED $4011 (chimes, horn strobes, horns) S5512 (strobes) APPROVED 3023572 approved MEA452-05-E 7125-1653 186 (indoor Strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) F r. R t • f SPECT• • • • •• •11• The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1 Y2-inch back box, 4-inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95. 110, 115, 135, 150, 177, and 185. •••• Strobe • • The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved,•f�orfira.protectiAtli''vice. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with DisabiIl ices Alt requirgfigi;tS Lpr visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shIllon6iiSt of a xer" flush tube and associated lens/reflector system. 900000 • •••• •••• Horn Strobe Combination �0060 4, •••••• The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 an(4$[ y Pj approved for, fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply \Aj4 %P.Anerica:"i" • Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating villa,qe range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options Von option to twitch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position twitch. Qr4WV:%ire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate og %poded &r non -coded power supply. • • • • • Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7-L x 4.8-W x 0.35"D (145 mm L x 122 mm W x 9 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA #& 153 Non -temporal High 57 56 69 75 95 NA NA 181 176 Non -temporal Medium 42 50 60 69 110 NA NA 202 195 Non -temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56..... 6Q Candela 150 NA NA 246 220 Coded Low 40 • 403• 52 50 Range g 177 NA NA 281 251 • • • • • 185 NA NA 286 258UL •••••• • •• • •••••• Max. Current Draw (rnA RMS), 2-Wire Horn Strobe, Standard Candela Range (15-115 cd) ••••+• 8-17.5Volts 16-33 Volts •••. •••• ..••• DC Input 15 15/75 15 15175 30 75 95 • • • • •VIO • 116 . • . • • • Temporal High 137 147 79 90 107 176 194 • • • •212 • 218 • • • +. • Temporal Medium 132 144 69 80 97 157 182 • • • • -101 210 • + Temporal Low 132 143 66 77 93 154 179 • 1-98 • 20 F • • • • • • Non -Temporal High 141 152 91 100 116 176 201 %21 • 229 • • Non -Temporal Medium 133 145 75 85 102 163 187 " 207 ; ten% • • Non -Temporal Low 131 144 68 79 96 156 182 201 "21'0 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (rnA DC Input RMS), 2-Wire 16-33 Volts 135 150 Horn Strobe, 177 High Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non -Temporal High 82 82 88 88 93 92 100 100 5 Non -Temporal Medium 78 78 85 85 90 90 98 98 6 Non -Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes ctrAlert Advance Dimensions Wall -mount horn strobes SpectrAlert Advance Ordering Information tow --cescription Wail Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P P2R-SP P2RH P2RH-P 2-Wire Horn Strobe, Standard cd, Red, Plain 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" 2-Wire Horn Strobe, High cd, Red 2-Wire Horn Strobe, High cd, Red, Plain P2W 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH P2WH-P 2-Wire Horn Strobe, High cd, White 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes 111 Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" • . . .... ••••.• .. .. • • ...... .. . ....• .. ..•••. .... .... . • .... .... ..... . . ...... . . • • • • • ••••.. ' . • • • • . • • • • • • • . • • Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SEER Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE' marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 02014 system sensor. 1 _ Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. visit systemsensor.con SENSOR for current product information, nclud.ng the latest version of this data sheet. ,vJ www.systemsensor.com AVDS10201 •1/10 SYSTEM SENSOR Outdoor, Selectable - Output Speaker Strobes and Dual -Voltage Evacuation Speakers SpectrAlert Advance outdoor, selectable -output speaker strobes and dual -voltage evacuation speakers meet virtually any outdoor application requirement. Features Plug-in design • Electrical compatibility with legacy SpectrAlert products Shorting spring on mounting plate tests continuity before installation • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings ('/a,1h, 1 and 2 watts) Ceiling- and wall -mount application Universal mounting plate for wall -and ceiling -mount units Weatherproof per NEMA 4X, IP56 Compatible with System Sensor synchronization protocol Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field -selectable candela settings on wall and ceiling units Agency Listings SIGNALING @ MEA LISTED approved >Sn 7320-1653:201 1MS-E SP The SpectrAlert Advance series offers the broadest line of outdoor speakers and speaker strobes in the industry. From metal and plastic outdoor back boxes, to white and red plastic housings, to wall and ceiling mounting options, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor speakers and speaker strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40oF to 151 °F. In addition, these speakers provide a broad frequency response range, low harmonic distortion and maintain a high sound pressure level at all tap settings to provide accurate and intelligible broadcast of evacuation messages. The entire SpectrAlert Advance line, including speakers, provides a plug-in design that reduces ground faults by enabling installers to pre -wire mounting plates and dress the wires before plugging in the speakers.To enable faster installation times, a shorting spring on the mounting plate provides instant feedback to ensure that wiring is properly connected. Furthermore, rotary switches simplify the selection of voltage and power settings. Both wall and ceiling speaker strobes include field -selectable candela settings that enable installers to quickly set each device to meet application requirements. The speakers'weatherproof plastic back boxes (shipped with product) and metal back boxes (available separately) are designed to accommodate in -and -out wiring for daisy chaining outdoor devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. The screw -hole knock -outs located on the back of the back box eliminate the need to drill holes for screw -in mounting. Both weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. Included with each back box is a screw -in NPT plug with an 0-ring gasket for a water tight seal. 'Advance Outdoor Speaker and Speaker Strobe Specifications General SpectrAlert Advance outdoor speakers and speaker strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance speaker strobes, when used with the Sync -Circuit- Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between —40°F and 151 °F from a regulated DC, or full -wave rectified, unfiltered power supply. Speaker Speaker shall be a System Sensor SpectrAlert Advance Model dual -voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. Speaker shall be listed to Underwriters Laboratories Standard S4048 for outdoor fire protective signaling systems. Speaker shall have a frequency raj)jegf 400 to 4000 Hz and shall have an operating temperature from —40°F to 150.8°F. Speaker shall have power taps and wattage settings tl�pt are elected b^otjrY switches. The speaker must be installed with its weatherproof back box in order to remain outdoor approved per UL listing S4048.The speakw shell be suitable for use in �' air handling spaces and wet environments. 0 • "�' 0 ' . • Speaker Strobe Combination 000000 • • • The speaker strobe shall be a System Sensor Model listed to UL 1638 and UL 1480 and be approved for fire protective sigr%frfg%stems. S�@*@rehall be • . capable of operating at 25.0 or 70.7 nominal Vrms and shall have a frequency range of 400 to 4000 Hz. Speaker shall have power4t" that are seleotac6*0rotary ... • . switch. The strobe shall consist of a xenon flash tube with associated lens/reflector system and operate on either 12 or 24 volts•T,ho rgpjje shall also featyre . 0 ; 0 0' selectable candela output, providing options for 15 or 15/75 candela when operating on 12 volts and 15,15/75, 30, 75,110, 11�,1% 13t, 177 or: S?edm&la when operating on 24 volts. The strobe shall comply with the Americans with Disabilities Act requirement for visible signaling jVjii jr�s, flashing at I Hz over 0 .... 0 00 the strobe's entire operating voltage range.The speaker strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. • The speaker strobe shall be suitable for use in wet environments. 0 0 0 * j. """ Physical Specifications• • . • • .. • Operating Temperature —40°F to 151 °F (-40°C to 66°C) • • • Dimensions, Wall -Mount SPS Speaker Strobe 6.0-L x 5.0"W x 4.7" D (including lens and speaker) SP Speaker 6.0- L x 5.0"W x 2.9" D Dimensions, Ceiling -Mount SPS Speaker Strobe 6.8-Dia. x 4.7" D (including lens and speaker) SP Speaker 6.8" Dia. x 2.9- D Dimensions, Wall -Mount Weatherproof Back Box 6.5"L x 5.5"H x 2.9" D Dimensions, Ceiling -Mount Weatherproof Back Box 7.2" Dia. x 2.9` D Nominal Voltage (speakers) 25 V or 70.7 V (nominal) Maximum Supervisory Voltage(speakers) 50VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12VDC/FWR or regulated 24 DC/FWR Operating Voltage Range (includes fire alarm panels 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) with built in sync) Operating Voltage with MDL Sync Module 9 to 17.5 V (12 V nominal) or 17 to 33 V (24V nominal) Frequency Range 400 to 4000 Hz Power Y4, Y2, 1, 2 watts A05-0425-005 UL Current Draw Data Candela Derating UL Max. Strobe Current Draw (rnA RMS) For K series products used at low temperatures, 8 to 17.5 Volts 16 to 33 Volts listed candela ratings must be reduced in —1 1-- -1 1-- accordance with this table. Standard 15 123 128 66 Candela Range 15/75 142 148 77 81 96 75 NA NA -158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant (dBA @ 10 ft.) 2W 1 W '/I W 'A W Outdoor Speaker 90 87 84 81 Outdoor Speaker/Strobe 89 86 83 80 Dimensions 7.19" C92.83=-1 0 00 �-°Y4e 0008�go°, 0o e U. o °8g000000 _&P N eve �000 7.14" 0 Ceiling -Mount Outdoor Speaker 5.48' 97=_ 2.83�—j 0 0 6.45" 0 0 Wall -Mount Outdoor Speaker OutputStrobe Listed Candela Candela rating at —40°F 15 Do not use below 32T 15/75 30 75 44 95 70 110 110 •••• 115 • • y15 •••• 135 135 • • • • 150 • 150 177 177 185 • r85 • • Ceiling -Mount Outdoor Speaker Strobe Wall -Mount Outdoor Speaker Strobe Surface Mountina Ceiling -Mount Speaker Strobe with Plastic Weatherproof Back Box Wall -Mount Speaker Strobe with Plastic Weatherproof Back Box Ceiling -Mount Speaker Strobe with Metal Weatherproof Back Box ■� Iltr`��rti.�i Wall -Mount Speaker Strobe with Metal Weatherproof Back Box Ceiling -Mount Speaker with Plastic Weatherproof Back Box • • • • Wall -Mount Speaker with Plastic WeatheW&gA %4ck Box • • • • •••••• Ceiling -Mount Speaker with Metal Weatherproof Back Box o � Wall -Mount Speaker with Metal Weatherproof Back Box Ordering Information for SpectrAlert® Advance Outdoor Speakers and Speaker Strobes White Red Description SPWK* SPRK* Outdoor Speaker (includes plastic weatherproof back box) SPSWK*' SPSRl(` Outdoor Speaker Strobe, Selectable Candela (15, 15/75, 30, 75, 95,110,115) (includes plastic weatherproof back box) SPSRHK Outdoor Speaker Strobe, Selectable Candela (135,150,177,185) (Includes plastic weatherproof back box) White Red Description SPCWK — Outdoor Speaker (includes plastic outdoor back box) SPSCWK — Outdoor Speaker Strobe, Selectable Candela (15, 15/75, 30, 75, 95, 110, 115) (includes plastic weatherproof back box) SPSCWHK — Outdoor Speaker Strobe, Selectable Candela, High cd (135, 150, 177, 185) (includes plastic weatherproof back box) Accessories White Red Description MWBBW MWBB Wall, Metal Weatherproof Back Box MWBBCW — Ceilinq, Metal Weatherproof Back Box Notes: *Add "-Tto model number for weatherproof replacement device (no back box included), e.g., SPWK-R. Especially for use with weatherproof outdoor flush mounting plates, WTP-SP and WTP-SPW Add "-P"to model number for plain housing (no "FIRE" marking on cover), e.q., SPSWK-P. �\ TEM 'I m2009 System Sensor. r �/ 3825 Ohio Avenue • St. Charles, IF 60174 Pend c P ficr b,e ttchange w1thoutnouceustsystemsenso,rnmra SENSOR Phone: 800-SENSOR2 • Fax:630-377-6495 tPtodoa r r mad -61the '9latest s- notmrsdausheer A0504Z 0 5 6.9•#2189 SYSTEM SENSOR Indoor Selectablem Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable -output speaker strobes and dual -voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features • Plug-in design and protective cover reduce ground faults • Universal mounting plate with an onboard shorting spring tests wiring continuity before installation • No extension ring required • Field selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4, Yz, 1 and 2 watts) • Speakers offer high fidelity and high volume sound output • 520 Hz capable with compatible FACP • Compatible with System Sensor synchronization protocol • Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products • Tamper -resistant construction • Updated modern aesthetics Aaeni Listinas SIGNALING UL 0 LISTED AFMD 54048 FM approved except 7320-1653 D505 for ALERT models 3057493 r� .•.. KI - el. -..: ;`.r1 • System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre -wire mounting plates, dress the wires, and confirm wiring continuity before plugging in the speakers. In addition, a protective plastic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings, and 7 field -selectable candela settings for both wall and ceiling speaker strobes. The low total harmonic distortion of the SP speaker offers high fidelity sound output while still offering high volume sound output for use in high ambient noise applications. L-Series makes installation easy • Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box . Flush -mount applications do not require an extension ring. • Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. • Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. L-Series Speaker and Speaker Strobe Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21i8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync•CircuitTM Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120OF from a regulated DC, or full -wave rectified, unfiltered power supply. Speaker strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, 177. Speaker The speaker shall be a System Sensor L-Series model dual -voltage transformer speaker capable of operating at 25.0 or 74067•nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency ranget44Q"t • •., 6 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps%a 6olCige that erg selected a • by rotary switches. • Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model listed to UL1480 and UL 1971 and be ai!p fed for fire arMlVe signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary swllil!&PAnd shall h&A" frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The At C 11all com I with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltageownn" The strcteliight shall consist of a xenon flash tube and associated lens/reflector system. • •. • • • • Synchronization Module • • • • • • The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protettive service. The module shall synchronize SpectrAlert strobes at 1 Hz. The module shall mount to a 411/16 x 411/16 x 21i8-inch back box *Ae module AalLalso• control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining t 10T more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120OF (0°C to 49°C) Humidity Range 10 to 93% non -condensing Dimensions, Ceiling -Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in, 25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in, 89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in, 73 mm With Surface Mount Back Box Electrical/Operating.- 6.9 in, 176 mm 5.37 in, 136 mm Nominal Voltage (speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage (speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage (strobes) Regulated 12 VDC or regulated 24 VDC/FWR 12 Operating Voltage Range (includes fire alarm panels with built in sync) 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4,000 Hz3 Power 1A, 112, 1, 2 watts 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3. 520Hz capable with compatible FACP. •••••• UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) 15 87 41 60 30 153 63 86 75 NA 11;y 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 •.•. • Ceiling -Mount Speaker Sound Output • • • Y • • • • • .. . • Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 ft) •' • . • • 1/4W 79 79 '��.•• •• ' """ 112W 82 82 .••• ...•0: 1 W 85 85 .�,�'. ' ' 2 W 88 88Ceiling-Mount ...• .... ..... . . Speaker Strobe Sound Output •• •• • •••••• Setting UL Reverberant (dBA @10 ft) UL Anechoic (dBA @10 fl' • • • ' 1/4 W 77 77 ..•.:. . • ••.. 112 W 80 80 • • • .... • • 1 W 83 83 • • • 2 W 86 86 L-Series Dimensions 1.00" 1.63- 6.80"dia 6.80" dia Ceiling Speaker Ceiling Speaker Strobe Surface Mountin Ceiling Speaker with Surface Mount Back Box L-Series Ordering Information Ceiling Speaker Strobe with ;LG; ie MourLt Back Box • • • • . • • • White Red Description SPCWL SPCWL Speaker only SPSCWL SPSCWL Speaker Strobe SPSCWL-P — Plain, Speaker Strobe SPSCWL-SP — Fuego, Speaker Strobe SPSCWL-CLR-ALERT — Alert, Speaker Strobe, Clear Lens Accessories White Red Description SBBCWL SBBCWL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 02017 System Sensor. Phone: 800 SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice, visit systemsensor.com SENSOR or current product information, S866' 1 the latest version of his data sheet. www.systemsensor.com nvosasso, • osin Indoor Selectable -Output Strobes and Horn Strobes for Ceiling Applications General System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthet- ics. The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any appli- cation requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela set- tings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring conti- nuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only DN-60938:B �J NOT1 F1 E RJ by Honeywell ,Ar4r SCRL .••••eC2W�00000 •.•• •.•• Architect/Engineer Sp-g&1flhatidos.:. •• •• • GENERAL ••••.. • L-Series ceiling -mount strobes arfd hornestrobe.9 shall mount to a standard 4 x 4 x 11h-inch back bo)o 4-inch octagon back box, or double -gang back box.-rW&%'ire: produgts ski;II also mount to a single -gang 2 x 4 x 17/8 inch back bolt. At universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall termi- nate at the universal mounting pTlate. Also, L-Series products, when used with the Sync•Circwt Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24- volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regu- lated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. STROBE The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective ser- vice. The strobe shall be wired as a primary -signaling notifica- tion appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/ reflector system. HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signal- ing appliances, flashing at 1 Hz over the strobe's entire operat- ing voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pat- tern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non - coded power supply. DN-60938:B • 5/15/17 — Page 1 of 4 SYNCHRONIZATION MODULE The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/1, x 411/1, x 21/8 inch back box. The module shall also con- trol two Style Y (class B) circuits or one Style Z (class A) cir- cuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) • Humidity Range: 10 to 93% non -condensing • Strobe Flash Rate: 1 flash per second • Nominal Voltage: Regulated 12VDC or regulated 24DC/ FWR1 • Operating Voltage Range 2: 8 to 17.5V (12V nominal) or 16 to 33V (24V nominal) • Operating Voltage Range with MLD3: 8.5 to 17.5V (12V nominal) or 16.5 to 33V (24V nominal) • Input terminal wire gauge: 12 to 18 AWG • Ceiling -Mount Dimensions (including lens): 6.8" diame- ter 2.5" high (173 mm diameter 64 mm high) • Ceiling -Mount Surface Mount Back Box Skirt Dimen- sions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non -filtered, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. UL Current Draw Data UL MAX. STROBE CURRENT DRAW (MA RMS) Candela 8-17.5 Volts 16-33 Volts DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. Page 2 of 4 — DN-609383 •5/15/17 ••.•.• •. . ••.••• • UL MAX. CH/ME/STROBE CURRENT DRAW (MA RMS), 2-WIRE HORN STROBE The 3.1 k is the sound of the mini -horns. The EM (which stands for Electro-mechanical) is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. Candela 8 VDC 16 VDC 15 30 15 30 75 95 115 150 177 Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non -Temporal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 186 212 3.1 K Non -Temporal High 111 172 69 94 144 164 202 • • • 229 • • 2 0 3.1 K Non -Temporal Low 103 169 54 88 131 155 18 217 259 • • • • 0000 • • • • Candela 16VFWR 15 30 75 95 115 • • • ISO • • 47 Temporal High 107 135 179 198 223 • •.. "4 •286 Temporal Low 78 101 151 172 199 • 2Q9 • 462 Non -Temporal High 107 135 179 198 223 • . 4 ' 286 Non -Temporal Low 78 101 151 172 199 229 • • 2fr2 • • 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data HORN AND HORN STROBE OUTPUT (DBA) Switch Position Sound Pattern dB 8-17.5 Volts 16-33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 DN-60938:6.5/15/17 — Page 3 of 4 Product Drawings: L-Series Dimensions w 6.£" 2.47 1.37 i Horn Strobes (Ceiling) Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC-Listed — S4011 Ceiling horn strobes — S5512 Ceiling strobes — S5512 Strobe -only ALERT devices • FM Approved (All except ALERT models) • CSFM Listed: 7135-1653:0503 (Ceiling Horns and Ceiling Horn Strobes), 7125-1653:0504 (Ceiling Strobes) Product Line Information CEILING HORN STROBES PC2WL(A) (-E)(-F), PC2RL(A) (-E)(-F). 2-Wire, Horn Strobe (White, Red). CEILING STROBES SCWL(A) (-E)(-F), SCRL(A) (-E)(-F). Strobe (White, Red). SCWL-CLR-ALERT. Strobe, ALERT (White). ACCESSORIES TR-21N, TR-2. Universal Ceiling Trim Ring (White, Red). SBBCWL, SBBCRL. Ceiling Surface Mount Back Box (White, Red). NOTE: A" suffix indicates ULC-Listed model. ULC-listed devices include required French labeling. See Agency Listings for listing details. NOTE: A" suffix indicates ULC-listed models, ULC models have FIRE/FEU marking on cover. NOTE: ULC-listed models add "-E" suffix for English only "FIRE" marking on cover. NOTE: ULC-listed models add "-F' suffix for French only "FEU" marking on cover. I 2.50 0 • -o Surface Mount Back E39yJCeilingJ.•• NOTIFIERO and SpectrAlertO are registered trademarks and Sync•CircuitTM is a trademark of Honeywell International Inc. 02017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. 'SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. RGINFMINC & MANIFAETIMNI All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — DN-60938:13 • 5/15/17 SYSTEM �30 SENSOR" Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlertO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 IF • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING U� FM LISTED S4011 (chimes, horn strobes, horns) APPROVED MEA approved 7300-1653 187 (outdoor strobes) 7125-1653 188 (horn strobes, chime strobes) S3593 (outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653.189 (horns, chimes) SPECT�wt •• see* SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40OF to 151 OF. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe ' • • • The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approve: for iire,protectivg 14'Ace. "": • The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities A(i requirarflfts fpr • 0 visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shemlctw of a xenGRfI&h 090600 tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order tcR1*t8A41DUtdoor approved • • per UL. The strobe shall be suitable for use in wet environments. • • • • • • • • : • •"; • • • • •••• •••• Horn Strobe Combination ••••• • - •••••• • • The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and sr%q,f Papprov: d Om: • ••••• fire protective service. The horn strobe shall be wired as :primary -signaling notification appliance and comply with the Americans with •••••- • ••••• Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating v tag�ra�ge. The strode ' • light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility aptions Ind an c�tipQ �• • •' • • • switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by: mugip� positien switch. • • On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models stlell operate on a oohed or •.•••- • - non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved p'6r:.16• •fhe horn strobe shall be suitable for use in wet environments. Specifications Operating Temperature -40°F to 151 °F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6"L x 4.7-W x 2.5"-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1 "W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data �rt��aFra�-s�z�.irrza�lirrFr*�ma�:ioltiy r � , -. .. - 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA ft 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 • • • 50 115 NA NA 210 205 Coded High 57 • 55• 69 • • • WS 000000 High 135 NA NA 228 207 Coded Medium 44 • 461 . 56 • • F9 • o Candela 150 NA NA 246 220 Coded Low 40 • • •16• • 52 • • 4130 ....: • Range 177 NA NA 281 251 • • • • • • • • • 185 NA NA 286 258 • • • • •"• • • UL Max. Current • ••••• 8-17.5Volts 16-33 Volts •••••• •__ •_ ••••• DC Input 15 15/75 15 15l75 30 75 95 ' • • •110 • 115 • • • • • • • Temporal High 137 147 79 90 107 176 194 ; • • ; *;V 2 M 8 • Temporal Medium 132 144 69 80 97 157 182 ' '401 ; �02.1% " • • •' Temporal Low 132 143 66 77 93 154 179 ; • *V8 ' 207 ; • ; Non -Temporal High 141 152 91 100 116 176 201 121 ; .LLB. • ' Non -Temporal Medium 133 145 75 85 102 163 187 207 1 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output '8-17.5 candela ratings must be reduced in accordance with 16-33 24-Volt Nominal this table. S 4h CId Volts Volts Reverberant Anechoic OutputStrobe Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 wi c Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 81 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diaqrams 2.5" 3„ Wall -Mount Horn Strobes IN O •••• •••. ...... ••. .. . ...... erpropj ;:ck Box • • • • • • • • ..•. .... ..•.. .....• • . ••... . . . • ...... Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Horn Strobes P2RK*1 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: * Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add %R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and Wl-PW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM©2012 Sys:ern Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Przduct specificat ons subjecuo change without nonce. Visit systemsensorcom l SE/VSOff Phone: 800-SENSOR2 • Fax: 630-377-6495 for curre-tp,oducti-formation, including the latest version ofthis data sheet. AVDS01201 • 3/12 dn-1271:A1 • 1-307 302 Series Rate -Anticipation Heat Detectors General The Thermotech 302 Series rate -anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90oC) ratings. The 302 Series are normally -open devices designed espe- cially for fire detection and alarm systems. Features • Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. • Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. • Universal application. The 302 Series can be used in all areas for any type of occupancy. • Self -restoring. • Hermetically sealed. Shock resistant, corrosion resistant, and tamper -proof. Principles Of Operation The 302 Series rate -anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate -anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8" (10.48 cm). Base diameter: 2" (5.08 cm). Electrical Ratings Voltaue Current 6 - 125 VDC 5 amps 6 - 25 VDC 1 amp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50' (15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. NOTI FI E R° by Honeywell 1271pho1.lpg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) • FM Approved: (302-AW-135/-194; 302-ET-135/-194; 302-135/-194) • CSFM:7270-0021:001 1271 dia 1.tif FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0.040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW HERRMETMET E HIC SEAL Cut -Away View dn-1271:A1 • 12/23/08 — Page 1 of 2 Thermotech Model 302 Series Rate -Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-135 135°F All -Weather Vertical Mounting Note 2 below 302-AW-194 194°F All -Weather Vertical Mounting 302-ET-135 135°F All -Weather Vertical Mounting Note 3 below 302-ET 194 194°F All -Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting • • • • • Note 4 D;IQ� 302-EPM-194 194°F Explosion Proof Mounting • • • • AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. ••••• • • • •• • NOTE is For interior mounting in any atmosphere that is compatible with terminal -screw -type connections* •t fL ra. ling 50' x 50 (15.24 x •••• 15.24 meters). 000•00 NOTE 2: Hermetically sealed for moisture -proof or dust -proof installations. Requires no special backbox when Ve all-weather leads are properly spliced to "THIN" or equivalent type wire. •••••• • • NOTE 3: Hermetically sealed for moisture -proof or dust -proof installations. Requires no special backbox. Mas plastic hexagonal wrench grip bushing with 112" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outt eft r! : • NOTE 4: Explosion -proof for installation in hazardous locations. Has hexagonal wrench -grip bushing with 712" (1.2~/ cm) cM4Veads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electril• Co., a requal. • NOTIFIERO is a registered trademark of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I O 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — dn-1271:A1 • 12/23/08 DN-7045:1 • C-7 DVC Series Digital Voice Command cu DVC-EM by Honeywell Voice Control Systems General The DVC is the heart of an integrated, full -featured Audio Command Center. The DVC Digital Voice Command combines the capabilities of a powerful digital audio processor, an event - driven audio message generator, and a router. Designed for use with Digital Audio Loop (DAL) devices such as DAA2, DAX and DAA series digital amplifiers as well as the DS-DB, each DVC supports a dedicated audio network with up to eight channels of audio, five channels of firefighter telephone com- munications, and control and supervision for up to 32 DAL devices. The DVC has two wire digital audio ports to connect to wire DAL segments. Either or both ports may be converted to multi -mode fiber or single -mode fiber using fiber option modules. Larger audio systems incorporating hundreds of amplifiers can be created by networking additional DVC units via NOTI•FIRE- NET'". The DVC may be networked with ONYX® Series panels via NOTI • FIRE• NET with an NCA-2, or with an NFS2-3030 (running in network monitor mode). A DVC can be connected directly with a single NFS2-640 or NFS2-3030 Fire Alarm Con- trol Panel (FACP) to create a standalone integrated audio solu- tion as well. Refer to the DVC manual for details. When used as an Audio Command Center with Emergency Paging capability, the optional DVC-KD Keypad Display is required. NOTE: Unless otherwise noted, the term 'DVC" refers to the DVC- EM. Features • Programmable from NUP port using VeriFireO Tools. • Up to 32 minutes of standard quality or 4 minutes of high quality digital audio storage of user-selected/created mes- sages and tones. Supports twisted -pair wire media. Sup- ports single- and multi -mode fiber-optic media when used with fiber option modules. • 4-channel analog audio supported with optional DVC-AO • Up to 1000 audio sequences. • Message prioritization. • Equations support flexible programming for distribution of messages. • Electrically isolated digital audio ports for direct connection with up to 32 Digital Audio Loop (DAL) devices. Style 4 or 7 configurations supported. • Optional DS-RFM, DS-FM, and DS-SFM fiber modules may be used to convert one or both Digital Audio Ports for oper- ation with single -mode or multi -mode fiber. • DCC (Display and Control Center) capabilities when used with optional DVC-KD. • Firefighters' Telephone Communications to local FFT riser on DVC, 32 local DAL device FFT risers, and FFT communication to additional command stations via NOTI • FIRE • NET. • Local paging microphone option. • Remote microphone options. • Optional Digital Voice Command Remote Paging Unit (DVC-RPU), or DVC-RPU mode. NOT 1 F 1 E R° DVC Shown using CA-2 mounting option, SBB-C4, and ADDR-C4 door. • Broad All -Call functionality when used with DVC-KD (DVC- Keyboard Display): All Call, Page Active Evac Areas, Page Active Alert Areas, Page Inactive Areas. • Auxiliary input for 12 Vp-p analog low-level audio sources. Includes user audio level adjustment feature. • Auxiliary input accepts external audio sources such as tele- phone paging or background music. High impedance input accepts 600 ohm, line level, 1.0 VRMS, or 1.41 Vp-p low level audio. Selectable AGC, user control of audio level, and audio supervision are supported. • Associated NCA-2, or NFS2-3030 (programmed for net- work monitor mode) supports NOTI•FIRE•NET applica- tions. • Multiple audio command centers supported via NOTI • FIRE• NET. • Distribution of one channel of standard -level paging audio on NOTI•FIRE•NET. • Three standalone, non -network mode options: — NFS2-3030 (NUP to NUP) digital and analog. — NFS2-640 (NUP to NUP) analog audio only. — NFS2-640 with NCA-2 (NUP to NUP to NUP) digital and analog. • Push -to -talk relay, or logic argument. • Isolated alarm bus input, to be used for backup activation of alarm messages in the event network communication is lost. Installation Options The DVC provides flexible configurations based on one -row or two -row chassis options that mount into size "B", "C", or °D" CAB-4 Series cabinets. DN-7045:1 • 12/20/2013 — Pagel of 4 DVC-AO: Optional DVC Analog Output board provides four analog output circuits for use with AA or XPIQ Series amplifi- ers. Four -channel operation supported. CA-1: Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC and a DVC-KD (optional); and the right side houses a CMIC-1 microphone and its well (optional). CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis. CFFT 1: The CFFT 1 Chassis for Firefighters' Telephone mounts in the row directly under a DVC that is mounted in a CA-1 single row chassis. The CFFT 1 includes one FFT hand- set. The DP-CFFT Dress Plate (separately ordered, required) has one open position for mounting an ACS annunciator or a BMP-1 Blank Module Plate. CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC mounted on a half -chassis and one NFS2-3030 or NCA-2 mounted on a half -chassis. The right side houses a microphone/handset well. The CA-2 assembly includes a microphone. DPA-213 dress plate is required (below); the VP-213 Vent Plate is also required for top row configurations. ADDR Series doors with two-tier visibility are available for use with the CA-2 configura- tion: ADDR-64, ADDR-C4, ADDR-D4 (below). DPA-2B: Dress plate required for CA-2 chassis assembly. VP-26: Vent plate required for cabinet configurations where the DPA-213 is used for the top two row position. TELH-1: Firefighters' Telephone Handset for use with the DVC when mounted in the CA-2 chassis. Order separately. ADDR-134: Two -tier -sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-64. See DN-6857. ADDR-C4: Three -tier -sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-6857. ADDR-134: Four -tier -sized door designed for use with a CA-2 chassis mounted in the top rows. ADDR Series doors are sim- ilar to CAB-4 Series "DR" doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-134. See DN-6857. DPA-1: Dress panel, can be used with the CA-1 chassis when configured with a DVC, DVC-KD, and CMIC-1. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMIC-1 is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. ACT-4: Audio -coupling transformer. Used to electronically iso- late DVC-AO analog risers. ACT-25, ACT 70: Audio -coupling transformers for 25V and 70V high-level audio. Used to isolate and convert high-level audio to low-level, supporting applications with large numbers of analog amplifiers. DAX-3525(E)/DAX-3570(E): 35W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 2 Class B or 1 Class A output, shipped mounted on chassis. Options: BDA- 25/70 backup amplifier, DS Fiber modules. DAX-5025(E)/DAX-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with power supply and 2 Class B or 1 Class A output, shipped mounted on chassis. Options: BDA-25/70 backup amplifier, DS Fiber modules. DAA2-5025(E)/DAA2-5070(E): 50W, 25 or 70.7VRMS. Digital audio amplifiers with charging power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. RM-1 port, FFT port, Aux audio port. Supports optional BDA for backup ampli- fier or 2-channel operation, and DS Fiber modules. DAA2-7525(E): 75W, 25VRMS. Digital audio amplifiers with power supply and 4 Class B or 2 Class A outputs, shipped mounted on chassis. RM-1 port, FFT port, Aux audio port. Supports optional BDA for backup amplifier or 2-channel oper- ation, and DS Fiber modules. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC while retaining digital audio dis- tribuition capabilities. Can be configured with up tedet DS- AMPs, supplying high-level risers spread4hroughd46il;^tal- lation. See DN-60565. • • • 00 DS-AMP/E: 125W, 25 VRMS, or J QQW, 70VRMS. A)jAMS requires DS-XF70V step-up transf0rWA Qigital Serie%Ampli- fier, part of the DS-DB system. See Q ;iV663. 0000 DS-BDA: Digital Series Backup "Otal AmpAffo&.• 3 or 70VRMS, can be configured to act jVjqV-to-onV bacl�up for DS-AMP/E amplifiers. Can also be Programmed4oprovde a second audio channel for a DS-AMA? See DN-60A3. BDA-25, BDA-70: Backup Digital �mpllfi2j, 25 or 70.7VRMS, can be configured to act as a one-to-one backup:x." and DAA2 series amplifiers. For DAA2 terios only, s4ports alter- native second channel operation. • • • • • • DS-RFM, DS-FM, DS-SFM: Fiber conversion modu%s for DVC, DS-DB distribution board, and DAX and DAA2 Series amplifiers. See DN-60633. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running SR4.0. For DAA-50 series amplifiers, see DN-7046. For DAA-7525 Series, see DN-60257. — DAA-5025: 50W, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted -pair wire media. (For multi - mode fiber-optic media order DAA-5025F. For single - mode fiber-optic media order DAA-5025SF.) — DAA-5070: 50W, 70.7Vrms Digital Audio Amplifier assembly with DAA-PS power supply board, shipped mounted to its chassis. Supports twisted -pair wire media. (For multi -mode fiber-optic media order DAA-507OF. For single -mode fiber-optic media order DAA-5070SF.) — DAA-7525: 75W, 25Vrms Digital Audio Amplifier assem- bly with DAA-PS power supply board. Shipped mounted to its chassis (no battery charger on DAA-7525 power supply board). Supports twisted -pair wire media. (For multi -mode fiber-optic media order DAA-7525F. For sin- gle -mode fiber-optic media order DAA-7525SF.) SEISKIT CAB: Seismic kit for CAB-4 series cabinets. Includes battery bracket for two 26AH Power Sonic batteries and TELH- 1 telephone handset strap. See document 53829. SEISKIT DAA: Seismic kit for DAA, DAA2 and DAX series amplifiers, required when using CHS-BH1 chassis. Includes battery bracket for two 12AH Power Sonic batteries. See docu- ment 53851. DN-7045:1 • 12/20/2013 — Page 3 of 4 . . .... ...... ...... .. . ...... .... .... . . .... .... ..... ...... . . ..... .. .. . ...... . . . . ...... ONYXID, NOTIFIERO, and VeriFire® are registered trademarks of and NOTI•FIRE•NEr" is a trademark of Honeywell International Inc. STO is a registered trademark of AT&T. 02013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — DN-7045:1 • 12/20/2013 The CA-2 supports a DVC, paging microphone, optional FFT telephone, and mounting location for an NCA-2 or NFS2- 3030D CPU. The ADDR audio door series can be used when a CA-2 is mounted in the top two rows. The CA-1 supports a DVC and an optional microphone in a single row. For firefight- ers' telephone applications with a CA-1, the CFFT-1 can be mounted in the row below the CA-1. NOTE: For NFS2-640/DVC applications using DAL devices, an NCA-2 is required to annunciate DAL device events. Refer to the DVC System Audio Product Application Guide (part number M-AG-DVC) for more details on DVC applica- tions). Specifications • 24 VDC power (TB1): 24 VDC, 1.0 A, non-resettable, power -limited by the source. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted -pair. • Digital audio ports, wire media, A and B (TB2, T133): Maximum distance per segment is 1900 feet (579.12 m) on Belden 5320UJ (18 AWG, TP) FPL cable: 18 AWG (0.821 mm2) twisted -pair, foil -shielded, power -limited. Consult wir- ing documentation provided in document P/N 52916ADD:C Addendum to DVC and DAA Manuals. • Digital audio ports, single- and multi -mode fiber-optic media: (See notes below) — DS-FM and DS-SFM fiber option module (no direct DAA connection): • 6.5d8 maximum attenuation for multi -mode with 50/125 micrometer cable @ 1310 nm. • 10d8 maximum attenuation for multi -mode with 62.5/ 125 micrometer cable @ 1310 nm. • 30dB maximum attenuation for single -mode with 9/125 micrometer cable @ 1310 nm. — DS-SFM (single -mode fiber DAA connection): • 17d8 maximum attenuation for single -mode with 9/125 micrometer cable at 1310 nm going from the DS-SFM to the fiber DAA. • 4d8 maximum attenuation for single -mode with 9/125 micrometer cable going from the fiber DAA to the DS- SFM. • 12d8 minimum attenuation going from the DS-SFM to the fiber DAA. — DS-RFM (multi -mode fiber DAA connection): • Attenuation going from the fiber DAA to the DS-RFM: • 2clB maximum attenuation for multi -mode with 50/125 micrometer cable @ 850 nm for the DS-RFM. • 4dB maximum attenuation for multi -mode with 62/5/125 micrometer cable @ 850 nm for the DS-RFM. • Attenuation going from the fiber DS-RFM to the fiber DAA: • 12dB minimum' attenuation, 16dB for both cable types. Notes: 1. If the length of the fiber run results in an attenuation of less than 12dB, a suitable attenuator must be used. 2. ST@ Style connection required at DAA end of any fiber connection. LC style connectors are required for the DS- FM, DS-RFM, and DS-SFM. • Auxiliary input A (AUX A, T134): Signal strength from low- level analog audio input: maximum 1.0 VRMS, or 1.41 Vp-p. Optional supervision is selectable through programming. Recommended wiring: 18 AWG (0.821 mm2) twisted -pair; max. 14 AWG (2.08 mm2). Auxiliary input must be in the same room as the DVC. • Auxiliary input B (AUX B, TB14): Signal strength from low-level analog audio input: 12 Vp-p nominal, 15 Vp-p maxi- Page 2 of 4 — DN-7045:1 • 12/20/2013 mum. Optional supervision is selected through program- ming. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted -pair. • Remote microphone interface (T139): Recommended wir- ing: 14 to 18 AWG (2.08 to 0.821 mm2) twisted -pair. Power - limited. Maximum distance between remote microphone and DVC: 1000 feet (300 m). • Push -to -talk interface (T1310): Dry contact. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted - pair. • Alarm bus (TB12): Power -limited by source. Recom- mended wiring: 14 to 18 AWG (2.08 to 0.821 mm2) twisted - pair. .•00 • FFT riser (T1313): Power-limited•output. Class A4.i*le�Z) or Class B (Style Y) operation. Styleef 4o-wire wnioctions require a 3.9K ohm, 1/2 watt rpjigfp; jP/N K'3.qM.Maxi- mum wiring resistance (including individual telephone zone to last handset) permitted is 50 ohms, 10,000 feet (� 048 m) maximum wiring distance at 1,?O � . (3.31 g ";j IQ last handset. •••• •••• • Optional DVC-AO analog autilcj b%put ciZ(Wi6s; JI35, TB6, TB7, and T138): SuperviSCd,•power-limited outputs. Signal strength: +12 Vp-p nominaM*46JVP-p maximum. Rec- ommended wiring: 18 AWG (0.421 m4) twistjjd-paid; max. 14 AWG (2.08 mm2). Maximum jmpedance: 6A:e1"1..• • • . Standards and Codes • • The Digital Voice Command DVC and DVC-EM comply with the following standards: • NFPA 72 2002 National Fire Alarm Code. • Underwriters Laboratories Standards UL 864, 9th edition, and UL 2572. • Underwriters Laboratories of Canada (ULC) ULC-S527-99 Standard of Control Units for Fire Alarm Systems. Listings and Approvals The listings and approvals below apply to the DVC and DVC- EM Digital Voice Command. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635. • ULC Listed: S635. • FM Approved. • CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 (NFS2-640). • FDNY: COA#6114 (NFS2-3030): COA#6085, COA#6121 (NFS2-640). • City of Chicago approved: High Rise, Class 1, Class 2 (NFS2-3030, NFS2-640, NCA-2). • City of Denver approved (NFS2-3030). • PSB Corporation approved (Singapore) (NFS2-3030). Product Line Information DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. Supports twisted -pair wire media. Options: DS Fiber modules, DVC-RPU. DVC-RPU: Digital Voice Command Remote Paging Unit. Includes the keypad/display. Supports twisted -pair wire media; use DS fiber modules for fiber media. See DN-60726. DVC-KD: Keypad for local annunciation and controls; status LEDs and 24 user -programmable buttons. DN-60556:C DAA2 Series �J NOT 1 F 1 E R° Digital Audio Amplifiers by Honeywell Voice Control Systems General The DAA2 Series amplifiers are multi -featured amplifiers with digital audio functionality. Each DAA2 is capable of accessing and processing one of up to eight audio channels on the DVC audio loop, amplifying the signal, and distributing it via four Class B or two Class A outputs. A DAA2-50 or DAA2-75 series amplifier is capable of mounting an optional BDA Digi- tal amplifier, which can be used to provide one-to-one ampli- fier backup, or to support two -channel operation, or increased output wattage to 10OW (100W option applies to DAA2-50 series only, other rules apply). The DAA2 has two wire digital audio ports to connect to wire DAL (digital audio loop) segments. Either or both ports may be converted to fiber using fiber option modules. Up to 32 devices, such as DAA2 amplifiers, can be con- nected to the DAL on one DVC Digital Voice Command unit. DAA2 amplifiers may be mixed with DAX and DAA series amplifiers on the same DAL. An optional Firefighter telephone riser on the DAA2 supports local and network FFT communications. A DAA2 also sup- ports use of an RM-1 remote microphone. DAA2 amplifiers can store backup alarm and trouble mes- sages, and provide an adjustable background music input. Features • Listed to UL Standard 864, 9th edition. • 50 W total output power at 25 VRMS (all DAA2-5025 mod- els) or 70 VRMS (all DAA2-5070 models). • 75 W total output power at 25 VRMS (all DAA2-7525 mod- els). • Supports two Class A high-level audio outputs; or four Class B outputs. • Optional BDA amplifiers support alternative configura- tions. • Backup amplifier - supports one-to-one backup (all DAA2 models). • Primary amplifier - supports two -channel operation (all DAA2 models). • Primary amplifier - increase power up to 100W, one- or two -channel operation. (DAA2-50 series only, configura- tion rules apply.) • Supports one -to -many amplifier backup applications using the same model DAA2. • Firefighter telephone riser supports 7 active firefighter telephones. System Release 3.0 and higher supports optional configurations: direct connection for up to 7 fire- fighter telephones, or connection to multiple FTM-1 mod- ules. • Remote microphone paging option with RM-1. • Audio output activation via network control -by -event equa- tions resident within the DVC. • Two wire digital audio ports that can be converted to fiber using fiber option modules. Support Style 4 or 7 configura- tions. • Auxiliary input for 1 VRMS, to' be'dsed for background music input, an interface with Jt2 (Ppne pagingosource, or other compatible audio soueces. Ppidio levels oen be adjusted by end user. Optional supervision t�rough'pro- rammin . • Isolated alarm bus input, to be used for backup activation of alarm messages when normal digital communication is lost. • Programmable through VeriFire® Tools. • Up to 106 seconds of backup digital message storage for use in the event of communication loss (from the Veri- Fire® Tools message library, or created by the installer). • Battery charger disable provides battery sharing option for up to four DAA2s. • Disconnect of deeply -discharged battery (low battery dis- connect). Installation The DAA2 arrives from the factory already installed on its chassis. The DAA2 mounts in one row of any EQ or CAB-4 Series cabinet: The CAB-4 row can be covered using a DP- 1 B dress panel, ordered separately. One or two fiber option modules will plug directly onto a DAA2 for simple installation. A BDA backup amplifier mounts directly onto a DAA2. Batteries for the DAA2 may be installed in any of the following configurations: • In a CHS-BH1 optional battery chassis. The CHS-BH1 battery chassis will hold two 12.0 AH batteries, and mounts on the left side of the DAA2 chassis, so that the DAA2 and batteries are contained in a single cabinet tier. • In the battery row (bottom) of the CAB-4 Series cabinet, or in the bottom row of an EQ Series cabinet. • In a cabinet adjacent to the cabinet that holds the DAA2, with connections in conduit. External battery charging is supported. DN-60556:C • 7/19/17 — Page 1 of 4 Specifications CPS-24 POWER SUPPLY BOARD AC power (TB1) • Models using 120 VAC, 60 Hz input: — DAA2-5025 - 4.68A max. — DAA2-5070 - 4.69A max. — DAA2-7525 - 4.68A max. • "E" version models using 220-240 VAC 60 Hz input: — DAA2-5025E - 2.68A max. — DAA2-5070E - 2.68A max. — DAA2-7525E - 2.68A max. Recommended wiring: 12 to 14 AWG (1.6 mm O.D.) with 600 VAC insulation. Shipping Weight. 13 lb (5.9 kg). Secondary Power 5V and 24V AUX Outputs (TB2): 24 V AUX: Power -limited, 24V @ 0.5A, utilizes wire sizes 12- 18 AWG (3.31 mmz - 2.08 mm2. 5 V: Future Use. Battery Connections: Supplied cable connections to batter- ies. Battery Charger: Current -limited sealed lead acid battery charger which charges two 12 volt batteries in series, up to 200 AH. Charge Charge Charge 7 AH to 26 AH to 50 AH to 26 AH < 50 AH 200 AH Batteries Batteries Batteries DAA2-5025 Yes Yes Yes DAA2-5070 DAA2-7525 Yes Yes No DAA2-5025 or DAA-5070 w/BDA No No No in Group 2 of VeriFireO Tools Table 1: Battery Charging Capabilities DAA2 BOARDS Digital Audio Ports, wire media, A and B (TB2, T133): Max- imum distance per segment is 1900 feet (579.12 m) on Belden 5320UJ (18AWG, TP) FPL cable: 18 AWG (0.821 mmz) twisted -pair, unshielded, power -limited. For approved cable types, see wiring documentation, P/N 52916ADD: C Approved Wire Cables for Digital Audio Loops. Digital Audio Ports, fiber media, fiber option modules: Digital audio loop connectors support single- and multi -mode fiber with the use of fiber option modules. Refer to the Fiber Option Module datasheet for fiber specifications. Alarm Bus: Power -limited, supervised by source. Recom- mended wiring: 14-18 AWG twisted -pair. Requires 16VDC minimum @ 20mA across the terminals to activate. Nominal 24VDC. Remote Microphone Interface: RMI power: +24VDC, power -limited @ 100mA. Supervised. Recommended wiring: 14-18 AWG twisted -pair, Max. 14 AWG. Nominal AC signal strength 2.5VRMs, 3VRMS Max. Maximum distance between remote microphone and DAA2: 100 ft (304.8 m). FFT Riser: Power -limited output, supervised. Class A or Class B operation. Class B 2-wire connections require a 3.9k Page 2 of 4 — DN-60556:C • 7/19/17 ohm 1/2 watt resistor (P/N R-3.9K). Max. wiring resistance (including individual telephone zone to last handset) permit- ted is 50 ohms, 10,000 ft (3048 m) max. wiring distance at 14 AWG to last handset. Auxiliary Input: Signal strength from low-level analog audio input (such as background music or telephone paging): 1Vp_p max. Optional supervision through programming. Recom- mended wiring: 14-18 AWG, twisted -pair. Auxiliary input source must be within 25 ft. (7.6 m) of the DAA2, and within the same room. Speaker circuits: Power -limited outputs (exception: a DAA2- 5070 speaker circuit used with any Canadian RogT.IIjolator module is non -power limited. Speaker circuit 1 •J B­1 0� can not be used.). Supervision determinte4 by programming. DAA2-5025/70, Each circuit rated *up to 50 wjtV, D,6,A2- 7525, each circuit rated up to 75 IVAIRl' Recomm2nd2d wir- ing: 12-18 AWG twisted -pair (shieklQdteeommendedj. Class B or Class A: Class B requires 4?8k *end-of-line•reeistors (included, P/N ELR-20K). Class A.regwyes 10ec 40-line resistors (included, P/N R-10K) or�4v rjWrn. `total wattage may vary per configp4 tipp.' ; • • • • • Backup: High-level audio input: t,� (DAA2-5025 and DAA2-7525). 70 VRMS (DAA2 50:0). ecommeccled wiring: 14-18 AWG. Not supervised whgn inactive. SL etS9e?d by backup source when active. Must•gr in same ropm or.enclo- sure. • • • Standards and Codes The DAA2 Series Digital Audio Amplifiers comply with the fol- lowing standards: • NFPA 72 2007 National Fire Alarm Code • Underwriter Laboratories Standard UL 864 • Underwriter Laboratories of Canada (ULC) ULC-S527-11 Standard of Control Units for Fire Alarm Systems. • Part 15 Class A conducted and radiated emissions as required by the FCC. • IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). • CBC 2007 (Seismic) Listings and Approvals These listings and approvals apply to the basic DAA2 Series Digital Audio Amplifiers. In some cases, certain modules may not be listed by certain agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S635. • ULC Listed: S635. • CSFM: 7165-0028:0243 (NFS2-640/NFS-320), 7165- 0028:0224 (NFS2-3030). • Fire Dept. of New York: COA#6212 (NFS2-640/NFS-320), COA#6211 (NFS2-3030). • FM approved. Product Line Information 50 WATT DAA2 AMPLIFIERS Shipped mounted to the chassis. DAA2-5025: 120 VAC Digital Audio Amplifier (50 W, 25 VRMS)• DAA2-5070: 120 VAC Digital Audio Amplifier (50 W, 70 VRMS)• • ••• • DAA2-5025E: 220-240 VAC Digital Audio Amplifier (50 W, 25 VRMS)- DAA2-5070E: 220-240 VAC Digital Audio Amplifier (50 W, 70 VRMS)- 75 WATT DAA2 AMPLIFIERS Shipped mounted to the chassis. DAA2-7525: 120 VAC Digital Audio Amplifier (75 W, 25 VRMS)- DAA2-7525E: 220-240 VAC Digital Audio Amplifier (75 W, 25 VRMS)- •••• BDA BACKUP DIGITAL AMPLIFIERS ° • • • • • • ° • • • • • • BDA-25V: Backup Digital Amplifier (25 VRMS), switch set- • •. 6 : .. • • ° tings for 75, 50, and 35 W operation. Provides a second •.. • • . •..' • ° • • •; • audio channel when as a amplifier. programmed primary . ••;•, ° • BDA-70V: Backup Digital Amplifier (70 VRMS), switch set- • • • • • • • • • • tings for 50 and 35 W operation. Provides a second audio • • . • • • •.. •.' • • • •. channel when programmed as a primary amplifier. • • . • • •,. . • • • •.. FIBER OPTION MODULES • IDS -FM: Fiber option module for multi -mode fiber. Converts a :���°: •. wire DAP (digital audio port) to a multi -mode fiber port. : •..;. °' °' ° ° • • • • • DS-SFM: Fiber option module for single -mode fiber. Con- ' • • ° V • • % verts a wire DAP (digital audio port) to a single -mode fiber • ° • • • .oeo port. DS-RFM: Fiber option module for multi -mode fiber. Used exclusively for compatibility with multi -mode fiber DVC or DAA. ACCESSORIES CHS-131-11: Battery chassis. Holds two 12.0 AH batteries Mounts on the left side of the DAA2 chassis. DP-1 B: Dress panel: covers one tier of CAB-4 Series cabi- net. ACT-25, ACT-70: Audio -coupling transformers. Used with AA-30 or DAA2-series amplifiers to drive thousands of ampli- fiers in large system applications. SEISKIT DAA: Seismic kit for DAA, DAA2, and DAX series amplifiers. Required when using CHS-BH1 chassis. Includes battery bracket for two 12AH Power Sonic batteries. See doc- ument 53851. DN-60556:C • 7/19/17 — Page 3 of 4 V • •eel of •fee ••wf•• •• • ••wwwf • *too 00:0 •tote• •e•e wt•• •••of •tt••• • • •woe• • • • • • e f • ee •• • •w•••• • •wee•• • • • e • • ••tee• toot•• 0. • • NOTIFIER® and VeriFire® Tools are registered trademarks of Honeywell International Inc. 02017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ' O 9oo We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Country of Origin: USA. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4 — DN-60556:C • 7/19/17 DN-60977:A FSP-951 Series Intelligent Plug -In Photoelectric Smoke Detectors General The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the con- trol panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951 T. The FSP-951 R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features • New modern profile for improved aesthetics. • Designed to meet UL268 7th Edition. • Stable communication technique with noise immunity. • Low standby current. • Two -wire SLC connection. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Optional remote, single -gang LED accessory. • Dual LED design provides 360' viewing angle. • Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan sys- tems only). • Remote test feature from the panel. • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). • Built-in functional test switch activated by external magnet. • Built-in tamper -resistant feature. • Sealed against back pressure. • Expanded color options. • SEMS screws for wiring of the separate base. • Optional relay, isolator, and sounder bases. Specifications Sensitivity: • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter. — B300-6: 6.1" (15.6 cm) diameter. — B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4oz (96.4g) Operating Temperature range: • FSP-951, 0°C to 50°C (32°F to 122°F). • FSP-951T, 0°C to 38°C (32°F to 100°F). �J NOTIFIER' by Honeywell IJ, .. .. . ...... FSP-951 in %966 $ase • • • • • • • • • • FSP-951 R installed in a DNR/DNRW, -20oC to 70oC (-4°F to 158°F). UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed -temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 200pA ® 24VDC (one communica- tion every five seconds with LED enabled). LED Current (max.): 4.5mA 0 24 VDC ("ON"). Installation FSP-951 series plug-in detectors use a separate base to simplify installation, service, and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60981. NOTE: 1) Because of inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class "B') wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. DN-60977:A • 4/17/18 — Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document. In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listed: S911 • FM Approved • CSFM:7272-0028:0503 Product Line Information NOTE: • Detectors must be mounted to one of the Intelligent Bases listed below. • `A" suffix indicates ULC Listed model. • `IV" suffix indicates FlashScanO and CLIP device. FSP-951: White, low -profile intelligent photoelectric sensor, FlashS- can only. FSP-951A: Same as FSP-951 but with ULC listing. FSP-951-IV: Ivory, low -profile intelligent photoelectric sensor. FSP-951A-IV: Same as FSP-951-IV but with ULC listing. FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed -temperature thermal device. FlashScan only. FSP-951TA: Same as FSP-951T but with ULC listing. FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed -temperature thermal device. FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing. FSP-951R: White, low -profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FlashScan only. FSP-951RA: Same as FSP-951 R but with ULC listing. For use with DNRA. FSP-951 R-IV: Ivory, low -profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FSP-951 RA -IV: Same as FSP-951 R-IV but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 13300-6: White, 6" base, standard flanged low -profile mounting base. B300-6-IV: Ivory,6" base, standard flanged low -profile mounting base. 13300A-6: Same as B300-6, ULC listed. B300A-64V: Ivory, 6" standard flanged low -profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed. B501-BL: Black, 4" standard European flangeless mounting base. UUULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. Page 2 of 3 — DN-60977:A • 4/17/1 S B224BI-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B20OS-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B20OS-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable SQLwLdgr base in ••••• English/French (required in Canada•fpi ULC applications with S • Series detector applications. • B200SCOA-IV: Ivory Intelligent, prpg"able sounder base in English/French (required in Canada joi ULC applications with SQ••..; • Series detector applications, ULC lislinC . ••••• • B200S-LF-WH: White, Low Frequegcy. �Ielligentt pro UrammabTe : * * • sounder base. Produces a fundamental fiequenWeaf•SW Hz +/I 10% with a square wave or its equivalent; designed to meet tM2 • • • • NFPA 72 sleeping space requirement! 0: • • 0 • B20OS-LF-IV: Ivory, Low Frequency Intelligent' • priDNammadflV e • • sounder base. Produces a fundamental 0frequendy of 520 Hz */- • 10% with a square wave or its equ%%lent; desired -tee eet toe 0 •: NFPA 72 sleeping space requirement. • • • • B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. . . .... ...... ...... .. . ...... .... ...... ssss ssss •ssss •ssss• • • • • • • •ssss• •ssss •• ss • ••ssss •ssss• • • • •ssss• •ssss• • • • •sss,•Goes 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I 0 900 We try to keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. ENGINEERING I & MANUFACTURINGQUALITY SYSTEMS For more information, contact Notifier. Phone: 800) 627-3473, FAX: 203) 484-7118. www.notifiercom Page 3 of 3 — DN-60977:A • 4/17/18 DN-6861:A • AO-260 NCM-W, NCM-F NOT 1 F 1 E R° 0NYX8 Series (a Network Communications Modules by Honeywell I Network Systems General The Network Communications Module (NCM) provides NOTI- FIER's NFS-640, NFS-3030, and NFS2-3030 Fire Alarm Control Panels, and NCA and NCA-2 Network Control Annunciators with a means to connect to NOTI•FIRE•NETT"". Two types of NCM are available: NCM-W for connecting nodes with twisted - pair wire, and NCM-F for connecting nodes with fiber-optic cable. NCM-W Features • Supports twisted -pair wire medium. • NFPA Style 4 (Class B) operation or NFPA Style 7 (Class A) operation. • Two programmable data thresholds. • Transformer coupling provides electrical isolation between nodes. • Pluggable terminal wiring with strain relief. • Pluggable service connector (feeds signal directly through) in the event that power must be removed from a node. • 312.5 Kbaud transmission rate. • Data is regenerated at each node. • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer. • Enables software and database upload/download over NOTI • FIRE- NETT"^ • Repeaters are available to increase signal. • Repeaters may be utilized to switch media type. • Up to 3,000 feet (914.4 m) between nodes in a point-to-point fashion (actual distance varies with wire quality). NCM-W Interconnections: When wiring consecutive NCM-W boards, wiring may enter or exit at Port A or Port B. NCM-W port -to -port wiring is not polarity sensitive; use of Port A or Port B is arbitrary. An NCM-W may be connected to any of the follow- ing devices: MIB-W, MIB-WF, NAM-2321N, NCM-W (in another panel), NCS-W network connection, RPT-W, RPT-WF. NCM-W Switch Functions: The NCM-W provides two sets of switches to simplify network setup. Enable ground fault detec- tion by setting "ON" switch SW103 (Channel A); switch SW101 (Channel B). Activate on -board end -of -line resistors by set- ting "ON" switch SW100 (Channel A); switch 102 (Channel B). NOTE: Correct configuration is dependent on network design; refer to the NOTI•FIRE- NETT^ manual. For further information and diagrams, refer to the NCM Installa- tion Document, 51533. NCM-F Features • Supports fiber-optic medium. • NFPA Style 4 (Class B) or Style 7 (Class A) operation. • Data is immune to all environmental noise. • Optical isolation prevents ground loops. • NOTI•FIRE•NETTM fiber-optic medium. • Fiber type: 62.5/125 micrometers (multimode); or 50/125 micrometers (multimode). • Maximum attenuation is 8 dB with 62.5/125 pm cable and 4.2 dB with 50/125 pm cable. • Wavelength (1): 820 nanometers (use standard 850 nm fiber). • NCM-W • Connectors: STO style. • • • • 312.5 Kbaud transmission rate. : • • �. • Data is regenerated at each node. Goes • Two network ports to allow simultaneous connection to fire alarm control panel and to programming computer. • Enables software and database upload/download over NOTI • FIRE• NETTM. NCM-F Interconnections: When wiring consecutive nodes/ repeaters, fiber cable must exit one board on Transmit (TX) and enter the next node/repeater on Receive (RX). The fiber-optic pair (RX, TX) from Port A of one node/repeater may be con- nected to either Port A or Port B of another node/repeater. An NCM-F may be connected to any of the following devices: MIB-F, MIB-WF, NAM-232F, another NCM-F, NCS-F network connection, RPT-F, RPT-WF. Common Specifications Temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is rec- ommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Mixing Wire and Fiber on the Same Network In some networks, it may be necessary to mix twisted -pair wire and fiber-optic cable. There are two solutions: • In any network, an RPT-WF may be used as an interface between wire and fiber. • In a network that uses an AFP1010 or AM2020, a MIB- WF may be used as the interface between wire and fiber. DN-6861:A • 11/30/06 — Page 1 of 2 • Mounting Both NCM-W and NCM-F can be installed in any standard chas- sis such as the CHS-4L, CHS-M2, CHS-M3 or CHS-4N (see panel sheets). Additionally, the NCM-W can be door -mounted on the ADP-4B dress panel on a single-space blank plate (BMP-1) for mounting in an CAB-4 Series cabinet. Agency Listings and Approvals The following listings and approvals apply to the NCM. In some cases, certain modules or applications may not be listed by cer- tain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: file S635. ULC Listed: file CS118. CSFM approved: files 7165-0028:214 (NFS-640), 7165- 0028:224 (NFS-3030), 7170-0028:216 (NFS-640), 7170- 0028:223 (NFS-3030). FM approved (NFS-640, NFS-3030). MEA approved: file 317-01-E (NCM-W, NFS-640, NCA). Product Line Information NCM-W: Network Communications Module, twisted -pair wire interface. NCM-F: Network Communications Module, fiber-optic cable interface. Diagnostic LED Indicators ,"• • A HI (green): Illuminates to indicate the NCM-W Port A is set for high threshold (NCM-W only). B HI (gr;ely:111L ninates jo indicate the NCM-W Port B is set for high threshold (NCM-W only). RCD A (green): Illuminates when the Npa js receiving date fsom NOTI•FIRE•NETTM on Port A. RCD B (green): Illuminates when the NCM is receiving data from NOTI•F11WNETTM on Fort B. STATA (yellow): Illuminates when the NCM has not received valid data from NOTI•FIRE•NETTM on Frdr?Alor at least 16 sec- onds. STATB (yellow): Illuminates when the NCM has not received valid data from NOTI•FIRE- NET„ M DAFpprt B for atleast 16 seconds. RECON (yellow): Illuminates when a reconfiguration on NOTI•FIRE•NETTM is in progress!PWk$E1 (greoroiUlumi- nates when the NCM is transmitting NOTI•FIRE•NETTM is in progress. RESET (yellow): Illuminates w4vothe miVocor4roller fails. POWER (green): Illuminates when +5 VDC is available. 06 • so • • • • • • • NCM-W (detail) EFB TERMS EFA TERMA oD 3 EARTH -CH B� -CH Ai Channel A & B Ground Fault Detection switches Connections and Network EOL Termination Resistor switches / lE1 LE A HI B HI LED6 LED7 Network Connection Ports (NUP) J3 J2 ❑ RCDA RCDB LED4 LED2 o O e o a o i sT<T e STATA STATB o ❑ z z RECON PUE1 LED3 LED5 RECON PULSEI a PR Diagnostic ED1 LED8 LEDs RESET POWER 6861ncm .—f NCM-F (detaiQ • 0 ARCDB L® Diagnostic LEDs Network L LED2 Connection Ports (NUP) STATA STATB LED3 LED5 R—N u RECON PULSEI II R T POWER LE01 rM, LED8 r 6861ncmf—f NOTI• FIRE-NETTM is a trademark, and ONYX® and NOTIFIER® are reg- istered trademarks of Honeywell International Inc. STE) is a registered trade- mark of AT&T. ©2006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING U MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-6861:A • 11 /30/06 DN-7047:G • AO-126 NCA-2 ONYX Series Network Control Annunciator General The NOTIFIER NCA-2 is a second -generation Network Con- trol Annunciator for the NOTI•FIRE•NETTm network, com- patible for use with ONYX® Series nodes such as the NFS2- 3030, NFS-3030, NFS-320, NFS-640 and NFS2-640 fire alarm control panels, as well as first -generation NCA Net- work Control Annunciators. Additionally, the NCA-2 may be configured with DVC Series products to create one or more Digital Audio Command Centers on NOTI•FIRE•NETTM. The NCA-2 provides system control and display capabilities for all, or for selected network nodes. The NCA-2 display consists of a 640-character backlit LCD display, and a control interface consisting of "soft" keys used to navigate screen menus, "hard" keys with fixed control func- tions, and a QWERTY keypad. When connected to one or more networked panels the NCA-2 provides network control and status/history display capabilities. It may also be configured as the Primary Display for displayless nodes on the network. Hardware Features • Certified for seismic applications when used with the appropriate seismic mounting kit. • Approved for Marine applications when a marine -listed version is used with marine -listed compatible equipment. See DN-60688. • Full supervision of all inputs and network integrity. • Enhanced -format 640-character LCD display with back- lighting. • ACS bus for LED or graphic annunciators (EIA-485). • Optically isolated printer interface (EIA-232). • 11 LED status indicators: Power, Controls Active, Fire Alarm, Pre -Alarm, Security, Alert, Supervisory, Trouble, Signal, Silence, CPU Failure, Point Disabled, Other Event. • Alphanumeric QWERTY rubber keypad. • Four status relays: Alarm, Trouble, Supervisory, Security (Form-C). • Nonvolatile real-time clock can be synchronized with net- work by master node. • Optional Security Keyswitch enables keypad functions. • Optional Security Tamper switch. • Supports up to 32 remote ACS annunciators and mod- ules. • Requires 24 VDC, and a network connection. • RDP port for LCD-160 or terminal mode LCD2-80. NOTE: NCA-2 Firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. Function Features • Individual Enable/Disable or Group Enable/Disable local for networked ONYX series panels. �J NOTI FI E R° by Honeywell •••••• NCA-2 in ABS-2Q bat*ox )••••• •fees• • •fees• • • • • Control ON/OFF networked ONYX series p�rle0: entrol points. • Read Status networked ONYX series panel points and zones. • Network paging control/HVAC control . • Network -wide: Acknowledge, Silence, Reset. • Lamp Test (local to NCA-2). • History Buffer (1000 Alarm events; 4000 System events). • Print NCA-2 programming and history reports. • Report status of networked panels and their respective field devices to a central station via a single UDACT-2 (see data sheet DN-60686). • One Master level, nine User level passwords. The Master can assign each User access levels (programming, alter status). • Interactive Summary Event Count display, event handling package. • Online programming and alter -status programs. • Intuitive user guidance program including interactive soft keys. • Enhanced Read Status/Alter Status displays. • New history filters for report displaying and printing: All Events, Only Alarms, Only Troubles, Only Supervisory, Only, Security, Time Interval, Point Range. • Fully programmable node -mapping subsystem. • Advanced/Basic Walk -Test program. • Timer control for Auto Silence, AC Fail Delay. • Meets Canadian ULC display requirements. • Environmental adjustment controls to maximize LCD legi- bility. • Meets NFPA requirements for Firefighter Smoke Control Station (FSCS) and HVAC. DN-7047:G • 3/1/17 — Page 1 of 4 • NCA-2 version 20 and higher complies with UL 2572 Mass Notification Systems. NCA-2 Indicators and Controls LED INDICATORS • POWER (green) illuminates when 24 VDC power is applied; LED goes out if power is removed and NCA-2 is using a battery. • CONTROLS ACTIVE (green) illuminates to indicate that the NCA-2 control functions are active. • FIRE ALARM (red) illuminates when at least one fire alarm event exists; flashes when any of these events remain unacknowledged. • PRE -ALARM (red) illuminates when at least one pre -alarm event exists; flashes when any of these events remain unacknowledged. • SECURITY (blue) illuminates when at least one security event exists; flashes when any of these events remain unacknowledged. • SUPERVISORY (yellow) illuminates when at least one supervisory event exists (i.e., sprinkler valve off normal, low pressure, fire pump running, guard's tour, etc.); flashes when any of these events remain unacknowl- edged. • SYSTEM TROUBLE (yellow) illuminates when at least one trouble event exists; flashes when any of these events remain unacknowledged. • OTHER EVENT (yellow) illuminates for any category of event not listed above; flashes when any of these events remain unacknowledged. • SIGNALS SILENCED (yellow) illuminates if the NCA-2 Silence key has been pressed or if any other node sent a Network Silence command; flashes if only some points on a node are silenced. • POINT DISABLED (yellow) illuminates when at least one dis- able exists on the network or in the system. • CPU FAILURE (yellow) activated by the watchdog timer hardware, indicates an abnormal hardware or software condition. Contact technical support. FIXED FUNCTION KEYS • Acknowledge • Signal Silence • System Reset • Drill/Alarm Signal • Fire Alarm Scroll/Display • Security Scroll/Display • Supervisory Scroll/Display • Trouble Scroll/Display • Other Event Scroll/Display The five keys labeled SCROLUDISPLAY allow the user to scroll through messages for the particular event type. For example, pressing the FIRE ALARM SCROLL/DISPLAY key will scroll through all fire alarm events, as details of each are shown in the display area of the NCA-2. NOTE: The OTHER EVENT SCROLLUDISPLAY key also scrolls between Pre -Alarm and Disabled events. • ACKNOWLEDGE — press this key to acknowledge off all active events. Page 2 of 4 — DN-7047:G • 3/1/17 • SIGNAL SILENCE — press this key to turn off all control mod- ules, notification appliance circuits, and panel output cir- cuits that have been programmed as Silenceable. • SYSTEM RESET — press this key to clear all latched alarms and other events and turn off event LEDs. • DRILL HOLD 2 SEC — press this key, holding it down for two seconds, to activate all silenceable output circuits. SPECIAL FUNCTION KEYS .... • PRINT SCREEN — press this key tc prir4 Qvrat is currawtly on the LCD screen. • • • • • • • LAMP TEST — press this key to te-Meg tED in!"toss on the left of the keypad and to chett?i"*are revision num- bers. • • • • • NEXT SELECTION/PREVIOUS SELEMW4 — these*6%*•are used when setting parameters •iM"@A-2 data fields; for example, choosing a device type•asoa filter fo: fdtl1itsting a Node History. ••.•.• • • BATTERY LEVEL — press this key to misplay yoltag�e and charging current level for systepn batteries. Di:pllays•levels for local AMPS-24(E) or AMPI-,?J E):�onnected to asso- ciated NFS2-3030 or NFS-3030 node. : .00. •••• Specifications Temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% t 2% at 32°C t 2°C (89.6°F t 1.1°F) per ULC. However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Product weight is 3 Ibs (1.36 kilograms). ELECTRICAL REQUIREMENTS The NCA-2 may be powered from a Main Power Supply AMPS-24(E) (see data sheet DN-6883) mounted in a seper- ate cabinet (see specifications below); or from any UL Listed non-resettable 24 VDC source from a NOTIFIER fire panel (see panel data sheets). The battery on the NCA-2 mother- board is for RTC and SRAM; holds the history memory through power failure. Replacements are available (P/N 31004). Power source: 1) AMPS-24 (120 VAC, 50/60 Hz, 4.5 A maximum) or AMPS-24E (240 VAC, 50/60 Hz, 2.25 A max- imum) power supply; 2) the NFS-640, NFS2-640 and NFS- 320 on -board power supply; or 3) a supervised +24 VDC power supply that is UL/ULC-listed for fire protective ser- vice. The current of the NCA-2 is 400 mA with backlight and 200 mA with the backlight off. Product Line Information NOTE: "C" suffix indicates ULC-Listed model. NCA-2: Network Control Annunciator. Requires a network communications module for networking. In direct connect applications NCM not required. NCA-2-C is for ULC applica- tions. Non -English versions are available: NCA-2-FR, NCA-2- HE, NCA-2-KO, NCA-2-PO, NCA-2-SC, NCA-2-SP, NCA-2- TC, NCA-2-TH. For English marine applications, order NCA- 2-M; for non-English Marine applications, order NCA-2-M and the appropriate KP-KIT-XX. (See DN-60688.) NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi -mode fiber versions available. See DN- 6861. a HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed network communications modules. Wire, single -mode fiber, multi - mode fiber, and media conversion models are available. See DN-60454 ABS-2D(C): Annunciator Backbox, Surface, black. Mounts one NCA-2 and one NCM-W/-F. ABS-2DR: Same as above, but red. ABS-4D(C) Annunciator Surface Box. ABF-1 B(C) Annunciator Flush Box. ABF-1 DB(C)Annunciator Flush Box with Door. ABF-26 Annunciator Flush Box. ABF-2DB(C) Annunciator Flush Box with Door. ABF-46 Annunciator Flush Box. ABS-1TB Annunciator Surface Box. ABS-1 B(C) Annunciator Surface Box. ABS-1TB(C) Annunciator Surface Box. ABS-213 Annunciator Surface Box. CHS-213: Chassis, required whenever the NCA-2 is mounted in an ABS-2D(R). CHS-M3: Chassis, mounts an NCA-2 in a single row of a CAB-4 Series cabinet. CA-2: Chassis, Audio, 2 rows. Mounts an NCA-2 and the DVC Digital Voice Command in two rows of a CAB-4 Series cabinet. CAB-4 Series Enclosure: Available in four sizes, "A" through "D". Backbox and door ordered separately; requires BP2-4 battery plate. See DN-6857. CAB -BM Marine System: Protects equipment in shipboard and waterfront applications. Order NCA-2-M; for non-English order NCA-2-M and the appropriate KP-KIT-XX. (See DN- 60688.) Also order BB-MB for systems using 100 AH batter- ies. For a full list of required and optional equipment, see DN- 60688. DP-DISP: Annunciator Dress Plate. Dress plate is used when NCA-2 is mounted in the top row of a CAB-4 Series cabinet with a CHS-M3 chassis. NCA-2RETRO: Kit for retrofit mounting the NCA-2 to a DP- DISP dress plate. NCA/640-2-KIT: Mounting kit for directly mounting the NCA-2 to CPU2-640 chassis. LCD-160: 160 character LCD annunciator. See DN-66940 LCD2-80: 80 character LCD annunciator. See DN-60548 TR-ABS213: Trim ring for semi -flush mounting of ABS-2D. Agency Listings and Approvals These listings and approvals apply to the NCA-2 and NCA-2-C. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: file S635. • ULC Listed: S527-11. • FM approved. g e • • • • CSFM: 7165-0028:0224, 7165-0;?q:0243. •0" • M EA: 232-06-E. • .. • . • • • • • FDNY: COA#6211, COA#6212. • • • •. • Marine Applications: Marine appr(j4d systems mubttie, con- figured using components itemized in A" Nrine bJYYX 6ys- tems datasheet DN-60688. Sp9Q", connections* and requirements for those components gre%e�eribed ir4Q4j:3jine- EQ installation document, PN 54756. When these requirements are followed, systems are approved bythe'iNowing agencies: • US Coast Guard 161.002/55/0 (Standard 4$• �F�i• and 161.002). : ' • • Lloyd's Register 11/600013 (ENV3 cltegory),9, e ••• • American Bureau of Shipping (ABS) Type Appal! NOTE: For information on the CAB -BM marine system, see DN-60688. DN-7047:G • 3/1/17 — Page 3 of 4 . • • .... % .... .... ..... . ....00 .... • 0000 NOTI•FIRE•NETTM is a trademark of, and NOTIFIER® and ONYX® are reg- istered trademarks of Honeywell International Inc. 02017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING A MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Country of Origin: US For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com or Page 4 of 4 — DN-7047:G • 3/1/17 D N-60726: C DVC-RPU Remote Paging Station General The DVC-RPU is a digital Remote Paging Unit for applications that require a compact remote paging station for emergency, fire, or general paging, initiation of automatic messages, vec- tored pages, and control capabilities for up to 24 points. One or many DVC-RPUs can be installed on the Digital Audio Loop of a DVC, each taking up one DAL address. Large systems can be configured with hundreds of DVC-RPU stations using multiple DVCs on NOTI•FIRE•NET'". The use of wire media is sup- ported by the base product, and multi -mode fiber, single -mode fiber, or hybrid combinations can be configured using DS-FM series fiber conversion modules. A DVC-RPU paging station may be configured using the follow- ing separately orderable components. • DVC-RPU, which includes the keypad/display • CMIC-RP microphone and microphone well • CAB-RP(R) small wall mounted cabinet The CAB-RP(R) is intended for MNS/ECS applications that call for a small, wall -mounted cabinet. Alternate solutions are config- ured using CAB-4 series cabinets. NOTE: The term 'DVC' refers to the DVC-EM (Digital Voice Com- mand, Expanded Memory). Features • DVC Programming for associated DVC-RPUs is accom- plished using VeriFire@ Tools version 6.7 or higher. • Up to three programmable message priority levels deter- mined by site programming may be used to allow high -priority emergency pages to override lower priority general pages. • 24 programmable buttons may be used for a range of func- tions, including: — Control for vectored pages. — Control for HVAC shutdown, door release, or other emer- gency functions. — Initiation of recorded messages and other event annunciation. —Annunciation of activation or trouble for audio zones or other points. • Electrically isolated digital audio ports for direct connection with up to 32 Digital Audio Loop (DAL) devices. Style 4 or 7. • Optional DS-RFM, DS-FM, and DS-SFM fiber modules maybe used to convert one or both Digital Audio Ports for operation with single -mode or multi -mode fiber. • Up to 32 DVC-RPUs are supported per DVC. Each DVC-RPU assumes one DAL address. • Distribution via NOTI•FIRE•NET'" of one channel of stan- dard -level paging audio on NOTI•FIRE •NET'". • Can be configured with the CAB-RP(R) and CMIC-RP to cre- ate a small wall -mounted remote paging station with control functions. • CAB-RP(R) cabinet includes provisions for custom labeling. Labels included with each DVC-RPU (for use with AHJ approval) are "MASS NOTIFICATION' and "HVAC EMER- GENCY SHUTDOWN." NOTIFIER° by Honeywell Installation Options CAB-RP(R): The DVC-RPU can be installed in a CAB-RP(R) cabinet with a CMIC-RP microphone and well. The CAB- RP(R) has provisions for mounting an STS-200 tamper switch (requires external monitoring such as FMM-1). CAB-4 Series: The DVC-RPU can be installed in a CAB-4 series cabinet using a CA-1 chassis and a CMIC-1 micro- phone and well. A DPA-1 dress plate is required with this configuration. Standards and Codes The DVC-RPU and associated components comply with the fol- lowing standards: • NFPA 72 2002 National Fire Alarm Code. • Underwriters Laboratories Standard UL 864, 9th edition. • Standard of Control Units for Fire Alarm Systems. Listings and Approvals The listings and approvals below apply to the DVC-RPU, CAB- RP(R), and CMIC-RP. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S635. • CSFM: 7165-0028-0224 (with NFS2-3030). • Fire Dept. of NY: COA#6114 (with NFS2-3030). Product Line Information DVC-RPU: Digital Voice Command Remote Paging Unit. Includes the keypad/display. Supports twisted -pair wire media; use DS fiber modules for fiber media. DVC-EM: Required control for the DVC-RPU. The DVC-EM is a digital audio processor with message storage for up to 32 min- utes of standard quality (4 minutes at high quality) digital audio. Supports twisted -pair wire media; use DS fiber modules for fiber media. See DN-7045. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules allow for multi -mode fiber, single -mode fiber, or hybrid connections to DVC or other DAL devices. See DN-60633. DN-60726:C • 10/07/2014 — Page 1 of 2 j CAB -RP: Black, single row wall -mounted cabinet for the DVC- RPU. The door provides a clear view of the interior, and is hinged downward to provide unimpeded user access from any direction. NOTIFIER key lock can be replaced with included thumb -turn latch (keyless entry is not intended for UL 864 remote microphone applications, requires AHJ approval). A mounting location for an STS-200 tamper switch (ordered sepa- rately) is provided. The CAB -RP can be used to house a DVC- RPU and a CMIC-RP. Alternately, the CAB -RP has two mount- ing locations that can be used for ACM-24AT or AEM-24AT • • • • • annunciators or a BMP-1 Blank Module Plate. An RM-1 remote : .' • • •.' • • • • • paging microphone can be installed on the right side of the • • .. • CAB -RP for applications where the DVC-RPU is not used. . • • • •.. • • '. CAB-RPR: Red version of CAB -RP. • • • • • • CMIC-RP: Microphone and microphone well for the CAB -RP .' • •' . • • • ' • • • • • • • cabinet. • • • • ' • ' TR-RP: Trim Ring for semi -flush mounting CAB-RP(R). ' • • • . • • CAB-4 Series Enclosure: Backbox and door for fire alarm con- • • • • " ' • � • • •' • trol panels and peripherals. See DN-6857. • • • • . • CA-1: Chassis, occupies one tier of the CAB-4 Series enclo- sure. The left side accommodates one DVC-RPU or DVC-EM • • ; "• • • ••.' with a DVC-KD. The right side houses a CMIC-1 microphone ; ;..••; and its well (optional). • . • CMIC-1: Optional microphone and microphone well assembly used with the CA-1 chassis in a CAB-4 series cabinet. DPA-1: Dress panel, can be used with the CA-1 chassis in a CAB-4 series cabinet when configured with a DVC, DVC-KD, and CMIC-1. t NOTIFIERO and VeriFirsO are registered trademarks of and NOTI•FIRE•NETTM is a trademark of Honeywell International Inc. 02014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I 0 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCINEERIN& & MANUFACTUMN& All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. 1 For more information, contact Notifies Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 — DN-60726:C • 10/07/2014