WS-19-659Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Issue Date: 04/08/2019
Location Address Parcel Number
945 NE 98TH ST, Miami Shores, FL 33138 1132060143450
Contacts
Permit NO.: WS-03-194 9
Permit Type: Windows/Shutters
Work Classification: Door Replacement
Permit Status: Approved
Expiration: 10/07/2019
GLENN HARRIS Owner J&G CARPENTRY INC Contractor
858 NE 97 ST, MIAMI SHORES, FL 33138 JAMES DAVIS
Other:3057537285
Business: 5613335042
Inspection Requests:
Description: CHANGE OUT 3 DOORS NO SIZE CHANGE IMPACT Valuation: $ 6,221.69 Ins30�pe tion R9
Total Sq Feet: 0.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$4.20
DBPR Fee
$2.00
DCA Fee
$2.00
Education Surcharge
$1.40
Scanning Fee
$9.00
Technology Fee
$3.25
Windows/Shutters Fee
$80.00
Total:
$151.85
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$151.85
Check # 32176
04/08/2019 $101.85
Check # 32113
03/27/2019 $50.00
Amount Due:
$0.00
In consideration of the issuance to me of this permit, 1 agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the fore oing—informat.on is accurate and that all work will be done in compliance with all applicable laws
regulating construction and zoning�F he�xt I authorize the,2ove co actor to do the work stated.
nature: Owyfr / _4plicant / Contractor / \Agent
Date
April 08, 2019 Page 2 of 2
NIE� ApPS )
Miami Shores Village
BUILDING
PERMIT APPLICATION
BUILDING ❑ ELECTRIC
Building Department RECEIVED
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 MAR 2 7 2019
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
❑ ROOFING
❑PLOMBING ❑ MECHANICAL 7PUBLICWORKS
FBC 20% 7
Master Permit No. WS^ d � �l.lJs
Sub Permit No.
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑ CHANGE OF ❑ CANCELLATION 7 SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 9 Li 5 AAF 926, Stree,+
City Miami Shores County: Miami Dade Zip: 3313y
Folio/Parcel#: (1- 3dC, `n l'-1 `39SQ Is the Building Historically Designated: Yes NO -
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): CL ran or Sandra Hac r lS Phone#:30S-469 -S391
Address:Q 15 /V (! G R t h S-f r cLf'
City: tom+ cv+► skn rc_S State: I' i Zip:3.3 /-M
Tenant/Lessee Name:
Phone#:
Email:
CONTRACTOR: Company Name: Phone#: � \
Address:
City: ��e5_ �+lrCC' .State: `[ �"'�- Zip:°
Qualifier Name: Q� \}rt Phor;e#:�,�
State Certification or Registration #: i /5> 3: Certificate of Competency #:
DESIGNER: Architect/Engineer:
Address:
City:
one#:
State: Zip:
Value of Work for this Permit: $ L x, / __ Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New [O Repair/Replace ❑ Demolition
Description of Work:
Specify color of color thru tile:
Submittal Fee $
Scanning Fee $
Technology Fee $_
Structural Reviews $
Permit Fee $
Radon Fee $
Training/Education Fee $
K,
CCF $
DBPR $
CO/CC $
Notary
Double Fee $
Bond $
TOTAL FEE NOW DUE $
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
0
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation h.
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulatir
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOL
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MA
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTENT
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDIN{
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with on estimated value exceeding $2500, the applicant mu
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the pers(
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job si
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, ti
inspection will not be approved an reinspection fee will be charged.
Signature Signatur
OWNER or AGENT QJ CONTRACTOR
The foregoing instrument was acknowledged before me this
V301 day of PAC , n` 120 JLl by
Map Ak6uk-ani �Afly who is personally known to
me or who has produced Wye C U eeig 5C as
identification and who did take an oath.
NOTARY
Print:
The foregoing instrument was acknowledged before me this
(�� day of MA ✓: 20 l `� by
JIgig who is personally known to
me or who has produced
identification and who did take an oath.
NOTARY PUBLIC:
Print:
as
Seal: Y
`••:
JULIOLORA
Seal: 2oiPft^ ✓e_
ANGELAYOUNG
yp°
k iF
misslon GG246122
* _
MY COMMISSION S FF 951069
'S �
Expires August 7, 2022
N9 o
o-i
EXPIRES: April 12. 20
EXPIRES:
�1,10F P
Bonded Thu6ue M S�rvkes
FOF�O�
F
-nru BuC; st Nakry Services
G
APPROVED BY
Plans Examiner
Zoning
Structural Review Clerk
(Revised02/24/2014)
Property Search Application - Miami -Dade County https://www.miamidade.gov/propertysearch/#/report/summary
OFFICE THE PROWERTY APPRAISER
Summary Report
Property Information
Folio:
11-3206-014-3450
945 NE 98 ST
Property Address:
Miami Shores, FL 33138-2534
_. _.............. _... _ ....... _......
GLENN A HARRIS
Owner
SANDRA W HARRIS
Mailing Address
------------
945 NE 98 ST
MIAMI SHORES, FL 33138-2534
PA Primary Zone
- --- -- -----
1100 SGL FAMILY - 2301-2500 SQ
------..................... -_.._.._......................_.._----
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
4/2/0
Floors
-------......................................................
1
-....-_
Living Units
.................................. ......__... _.................. _--._...........
1
Actual Area
2,915 Sq.Ft
Living Area
-----.............. -... --.................................
2,235 Sq.Ft
_.-....... _...... ........................ _...... _- ............. . -
Adjusted Area
2,567 Sq.Ft
Lot Size
10,300 Sq.Ft
Year Built
11953
Assessment Information
Year
...... -.._.... _.... ....--__.................... __.._- .... .... .......
Land Value
2018
- - -
$309,063
2017 2016
-------------
$309,063 $268,145
Building Value
$178,663
$178,663 $178,663
XF Value
$3,344
.....................................................
$3,344 $3,344
.......................... ............................ :......................................................
Market Value
$491,070
$491,070 $450,152
Assessed Value
$340,547
$333,5431 $326,683
Benefits Information
Benefit
_ -.
Type
2018
2017 2016
Save Our Homes
--.._.. - ---
Assessment
_.- ..............
Cap
--._.._._.....
Reduction
$150,523
$157,527i $123,469
_.... .........................
Homestead
.-....._.............................................
Exemption
........................ .............
$25,000
......... ..._ ........................ ,.._._.
$25,000 $25,000
Second
Exemption
$25,000
$25,000 $25,000
Homestead
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description 0
MIAMI SHORES SEC 3 PB 10-37
LOTS 19 & 20 BLK 80
LOT SIZE 100.000 X 103
21003-3046 012003 1
COC 21580-3787 08 2003 1
Generated On : 3/6/2019
Taxable Value Information
1 20181
2017
2016
County
...................................... .._.........................................................----....._..._...... ..................................
Exemption Value $50,000
---- --- ---..
$50,000 $50,000
Taxable Value
$290,547
$283,543
$276,683
School Board
Exemption Value
$25,000
$25,000
.. . ................................................
$25,000
Taxable Value
$315,547
$308,543
$301,683
city
....... _.... . ... --- ................... - - --._ _.._....--......_.........._..................................................... _......... _..... .........
Exemption Value $50,000 $50,000 $50,000
Taxable Value
1 $290,547
$283,543
$276,683
Regional
- . ................_....--------
Exemption Value 1 $50,000 $50,000 $50,000
Taxable Value $290,547
$283,543
$276,683
Sales Information
Previous Sale
Price
OR Book -Page Qualification Description
08/01/2003
_ ....................._.......--..................
01/01/2003
$385,000
........_...............................
$265,000
21580-3787 Sales which are qualified
....._....................................... . _- -- - --.................
21003-3046 :Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This webske may not reflect the most current information on record. The Property Appraiser and
Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/infotdisclaimer.asp
Version:
SPECIAL SERVICES CUSTOMER INVOICE
Store 6322 N MIAMI/BISCAYNE Phone: (305) 981-2959
12055 BISCAYNE BLVD Salesperson: LMM41-I
MIAMI, FL 33181 Reviewer: SBBOAD
Name
Phone
HARRIS GLENN
(305) 968-5381
Address 945 NE 98TH ST
Phone
Company Name
City MIAMI
Job Description DOOR INSTALL- FL# 16708.2
state FL Zip 33138
County MIAMIDADE
Page 1 of 6 NO. H6322-153309
-------------------------------------------------------
REPRINT
2019-03-11 15:42
- We reserve the right to limit the quantities of merchandise
"z� "DELIVERY #1 l MERCHANDISE AND SERVICE SUMMARY sold to customers q ^
REF # 101
STOCK MERCHANDISE TO BE DELIVERED:
REF #
SKU
QTY
UM
DESCRIPTION
PI
TAX
PRIC# EAW
EXTENSION
R02
1001-753-972
9.00
EA
1X8-8FT PT GC WEATHERSHIELD /
A
o $7.88
$70.92
R03
1001-753-990
9.00
EA
2X8-8FT #2PRIME PT GC /
$8.67
$78.03
R04
0000-252-677
81.00
LF
1-1/4 X2 PFJ WM180 BRICK /
N
$1.24
$100.44*
R05
0000-526-849
9.00
EA
11/16 X2-1/4X7' PFJ WM327 CAS LEG /
A
N
$4.321
$38.88*
810 - MD SE TO BE DELIVERED: REF # SOB ESTI wl- DATE: 03/16/2019 P.O. #22500729
1 REF #
SKU
QTY
UM
_
DESCRIPTION
I PI
TAX
PRICE EACH
EXTENSION_
SOS12
OOCC-916-413
1.00i
EA
FIBERGLASS IMPA / FIBERGLASS IMPACTS IBERGLASS 2 /
A
N
$1,169.80
$1,169.80
UNIT SIZE 37 1/2 X 81 PREHUNG PRIME TED FULL LITE
DOOR WITH BLANCA GLASS. LEFTA SWING WITH SATIN
NICKEL HINGES. DOUBLE BO / RAI AST JAMB WITH A 6 9/16
ALUMINUM SILL.
S0813
0000-916-413
1.001
EA
FIBERGLASS IMPA / FI S IMPACT SO JW EXT FIBERGLASS 2 /
A
N
$1,169.80
$1,169.80
UNIT SIZE 37 1/ 1/ BERGLASS PRIMED PREHUNG IMPACT
RATED FU R WITH BLANCA GLASS. LEFT HAND OUTSWING
WITH S L HINGES. DOUBLE BORE WITH A AURALAST 6/9/16
J NNN ALUMINUM SILL.
—'CONTINUED NTINUEt ON
NEXT PAGE"***
D
U�w
O�
Check your current order status online at
www.homedepot.com/ordemtatus
Page 1 of 6 NO. H6322-153309 * Indicates omer markdown
SPECIAL SERVICES CUSTOMER INVOICE - Continued Name: HARRIS
Page 2 of 6 NO. H6322-153309
. INSTALLER DELIVERY #1
L(Continued) REF #101
S031,� 0000-916-T i3 i 1,90 E_A,PREH"!vG F!BERGL / PRF_L,UNG FIBERGLASS cc'-,O JW EXT FIBERGLASS / A N $933.81 $933.81
UNIT SIZE 31 1/2 X 81 1/4 FIBERGLASS PRIMED PREHUNG DOOR 1/2 LITE
WITH BLANCA IMPACT GLASS AND 2 PANELS ON THE BOTTOM. LEFT
114 AURALASTAND ING JAMB ALSATIUMINUM SILL.N NICKEL INGES. DOUBLE BORE WITH 5
DELIVERY INFOR>I.ATION:!DELIVERY DATE: INSTALLER WILL SCHEDULE
INSTALLER WILL DELIVER MDSE TO: SITE OF INSTALLATION #101 AT TIME OF INSTALLATION.
`-�'TE''t �'.' Ea a Q ALL S,'O �r?E :� ? 1A1'-D1aE - I i-STAI Li=R WILL SALE CUSTOMER TO SCHEDULE INSTALL
,.:. ,
DATE.
tl�`I•:�LLATION #1
561.68
REF # 101
ESTIMATED INSTALL BEGIN BATE: 03/05/2019
ESTIMATED INSTALL END DATE: 04/04/2019
MERCHANDISE
TO BE INSTALLED:
,. REF #
SKU
QTY
UM
DESCRIPTION
R02
1001-753-972
9.00
EA
1X8-8FT PT GC WEATHERSHIELD
R03
1001-753-990
9.00
EA
2X8-8FT #2PRIME PT GC
R04
p 5
r 0 12
S0813
0000-252-677
0000-526-8 +9
0000-916-4 ; 3
0000-916-413
_ 81.00'
1 900
1.00
11.00
LFO-1/4
X2 PFJ WM180 BRICK
EAj
EA'ISO
EAISO
11/16 X2-1/4XT PFJ WM327 CAS LEG
JW EXT FIBERGLASS 28 DAYS OR LESS
JW EXT FIBERGLASS 28 DAYS OR LESS
i S0814
BASIC INSTALLATION
1 0000-916-413
LABOR:
1.00
EA
SO JW W EXT FIBERGLASS 28 DAYS OR LESS
l SKU
�0000-523
-672
DESCRIPTION
fY
1.00
LIM
EA
TAX,PRIQEEACH
N
$340.00
EXTENSION
$340.00
_ _
EXTERIOR DOOR FL-NAT/PRE-HUNG DOOR UP TO 38X98
OPTIONAL LABOR SELECTED INCLUDES:
OPTION
DESCRIPTION
I QTY
UM
ITAXI
PRICE EACH
EXTENSION
1
HAUL AWAY OF EXISTING
DOOR PER DOOR OPENING)/
1 3.001
EAJ
N
1 $0.001
$0.00
CONTINUED ON NEXT
PAGE
Page 2 of 6 NO. H6322-153309 Customer Copy
SPECIAL SERVICES CUSTOMER INVOICE - Continued Name: HARRIS
Page 3 of 6 NO. H6322-153309
INSTALLATION #1
(Continued) _
REF #101
3
_ -
Ur:,H�?I�G'r FOR WIPAC? GLASS UP TO 3r" WIDE X 96" HIGH/
-- �.00
�.� r Iy
$90.00
$270.00
_
%3
_ _
;STUCCO -VORK IN EXCESS C;- . MINOR CHIPS AND CRACKS
_
(SINGLE DOORS UP TO
3.00
EA. N
$150.00
$450.00
36"X96"/
11
1 MULTI DOOR DISC - EXTERIOR DOOR UP TO 36X96/
_
2.00
EA
N
$250.00
$500.00
1CUSTGM LABOR SELECTED INCLUDES:
_
OPTION I L?z �CFiFT lON
-- - � - Q �'-I-- ;1'.1_I;aX PRICE'=ACH EXTENSION-
__
4 - --- --_
r 1 -(REMOVE-IRON DOOR-
� ^;_00j ,4r PN $85 00 1 $255.00
- - - - -- --- --- -- --_-- -----------
C 2 BUCK PREP
— - -- - - -- ------ _
7 3.00 ra I R! $150 00, $450.G0
— -- --
`TALi.gTlO�l�iT !�f_A HARRIS,GLENN__
--
INSTALL LABOR CHARGE: $2,265.00
ADDRESS: 945 NE 98TH ST
TRIP CHARGE: $0.00
� CITY: MHANI; — T ATE:: F;--
ZIP: 33-138 'CREDIT i=09 Z DEPOSIT/MEASURE: $50.00
--- ------ ---S
3ALLS TAX R.A I'E- /.000 . AX: ,Merchandise - N ABO z h3_ a'$2 215.00
PHONE: (305) 9685381 ALTERNATE PHONE:
305 9685381
BASIC INSTALLATION LABOR INCLUDES:
* PRE -INSTALLATION JOBSITE INSPECTION
AND EXTERIOR TRItf/BRICKMOLD OF THE NEW DOOR WHEN THE
* DELIVERY WITHIN 30 MILE RADIUS OF STORE
CASING/TRIM IS THE SAME SIZE OR WIDER
* REMOVAL OF EXISTING DOOR UNIT
* INCLUDE NON -COLORED STUCCO PATCH TO REPAIR MINOR CHIPS
* INSTALL NEW SLAB OR PRE -HUNG EXTERIOR DOOR UNIT
AND CRACKS RESULTING FROM REMOVAL OF DOOR (FOR LARGER
* !NSTAl.It R ; O PROV;DE NECESSARY FASTENERS, SHIMS AND
STUCCO REPAIR, SEE OPTIONS)
CAULKING
* PRE -HUNG DOOR UP TO 72X96 INCLUDES DOUBLE DOORS AND DOORS
* INSTALL EXISTING OR NEW CUSTOMER PROVIDED DEADBOLT,
WITH SIDELIGHTS
LOCKSET AND KICK PLATE (IF APPI !(,ABLE) ON NEW DOOR
. FINAL CLEAN UP OF ALL DEBRIS RELATED TO INSTALLATION
ADJUST DOOR TO ENSURE PROPER OPERATION
'FINAL INSPECTION WITH CUSTOMER INCLUDING INSTRUCTIONS ON
DPILL HOLE IN JAMB FOR ALARM WIRING !N SAME LOCATION AS
CARE OF PRODUCT TO ENSURE PROPER OPERATION
IEXISTING DOOR
* INSTnI L NEV4 CUSTOMER PROVIDED SINGLE LAYER INTERIOR CASING
':UNLESS S'a AT ED ABOVE
-1 HIS INSTALLATION DOES NOT INCLUDE:
INSTALL DOORS OVER 72X96
INSTALL FIXED RECTANGULAR TRANSOM LITES NOT PART OF PRE-HUNGDOOR
UNIT
INSTALL FIXED ARCH TRANSOM LITE IN EXISTING OPENING
INSTALL MORTISE LOCKS ON WOOD DOORS (CUSTOMER PROVIDES)
REPAIR CARPENTRY TO EXISTING OPENING
DISCONNECT AND RECONNECT OF SECURITY SYSTEMSANIRING
*** CONTINUED ON NEXT PAbE *"*
Page 3 of 6 NO. H6322-153309 Customer Copy
SPECIAL SERVICES CUSTOMER INVOICE - Continued Name: HARRIS
Page 4 of 6 NO. H6322-153309
INSTALLATION #1
(Contintf)
FL='AST'ER, DRY,VALL OR SIDING WORK
STUCCO PATCH GREATER THAN 4", PAINT AND STAINING
INSTALL ALL AMERICAN DOORS
SPECIAL NOTES:
T. n?AY RE NOISY DURING YOUR INSTALLATION
FHE INSTALLER WILL BROOM CLEAN THE IMMEDIATE WORK AREA
=FORE CCMIPLETING THE INSTALLATION. AIRBORNE DUST IN OTHER
"RTS OF THE HOME IS A NATURAL OCCURRENCE AND IS THE
SPONSIBILITY OF THE CUSTOMER.
1N ADULT OVER 18 YEARS OF AGE WITH THE AUTHORITY TO MAKE
C!S!ONS ABOUT YOUR INSTALLATION MUST BE PRESENT DURING THE
SPE(:' IOiv (VIHEN APPLICABLE), DE!.;VERY AND INSTALLATION
STZI ACT! IRA: ivy^:%!F!CAT;ONS � BUST P;7 APPROVED Bl' RFG!ONAL SERVICES
MANAGER OR INSTALL MERCHANT
ELECTRICAL WORK
INSTALLATION #2
_
REF # 107
ESTIMA T ED INSTALL BEGIN DATE: 03/05/2019
ESTIMATED INSTALL END DATE: 04/04/2019
BASIC INSTALLATION LABOR:
SOU_ DESCRIPTION
Q Y l)C , TA_XEACH EXTENSION
_ _ _ �- _ _- - _ _ _
0000-523 EXTERIOR DOOR FL-NAT/PRE-HUNG DOOR UP TO 38X98
_PRICE
`EA
0.00 N $340.00 $0.00
-672
OPTIONAL LABOR SELECTED INCLUDES:
OPTION DESCRIPTION,
QTY UM TAX I PRICE EACH EXTENSION
*** CONTINUED ON NEXT PAGE
Page 4 of 6 NO. H6322-153309 Customer Copy
SPECIAL SERVICES CUSTOMER INVOICE - Continued Name: HARRIS
Page 5 of 6 NO. H6322-153309
INS'." LLATION #2
I
�- (Continued)
REF #107 - ----- ---—--------
—--------- -----
- _
r g � J 33 -LEAD-SAFE WORK PRACTICES �QTY X $1.00)/
--� 55_00 — E � f a $1.00
$55.00
_ — —
SITE NAME:
� INSTALL LABOR CHARGE:
$55.00
--HARRIS,GLENN _ _-- ---- -- —
_
ADDRESS: 945 NE 98TH ST
TRIP CHARGE:
$0.00
CITY: MIAMI STATE: FL ZIP: 33138
CREDIT FOR DEPOSIT/MEASURE:
$0.00
'AI_'=S 7a;; Rr^ / r �r305
, % I.; `- ""'` !� • ®
$55.00
ERNAT;y PHONE: 9685381
(305L9685381 ALT —(--�
L
- --
EIJO OF INSTALLR2_
_
INSTALLATION #3
REF_# 111
-. - -
�—.N `ALL E�r;N €m�TZ. O'/05!20z!^
;_WTlk7;4 `� rig
I r iA..ST� ..__ =ENDDAT � E: 04'04!20 9 ..
1
BASIC INSTALLATION LABOR:
SKU DESCRIPTION
QTY
UM
TAX
PRICE EACH
EXTENSION
0000-114 !BUILDING MATERIALS PERMIT FEE-NAT/
1.00
t
EA
N
$0.01
$0.01
_ -442 1
OPTIONAL LABOR SELECTED INCLUDES:
OPTION
DESCRIPTION
QTY
UM
TAX
PRICE EACH
EXTENSION
7 PERMIT FEE/
r - — -- --------------
390.00 EAI N— $1.00
$390.00
--- - --
..'NS T.�:'.- LA T ION SITE NAME: HARRIS,9L NN
-t-- - - --
INSTAI_i LABOR CHARGE:
$390.01
IABDRESS: 945 NE 98TH_ST
TRIP_CHAR_GiE:,
$0.00
_ _—
CITY: _ It1:AM
I ! STATE FL _ ZIP: 33138
--
�-- ----------- ------
_ Ch��:DIT FOR rEPOSIT/MEASURE:
$0.00
;t U; .'TY: Mil ! D%A'-' ` AI ES 'r�3X Rt, � _3� A3C: Nlc�c ianda�;? IN _A
OR r!_ -„ � s� 't�' o s
$390.01
PHONE: (305) 9685381_ -- ALTERNATE PHONE: 305) 9685381
INSTALLER SPECIAL INSTRUCTIONS: FL# 16708.2
Sr?51C I.No" T.',L ATION LABOR
INCLUDES:
ARRIVE AT JOBSITE ON DAY OF INSTALL AND LEAVE WITH CUSTOMER.
POSTAGE AND ADMINISTRATIVE).
OR INSTALLER. IF DELIVERED TO INSTALLER, THE INSTALLER WILL
FEES, ENGINEERING, WIND LOAD CALCULATIONS, RECORDING,
PICK UP FROM THAT MUNICIPALITY AND DELIVER TO EITHER JOBSITE
' ALL FEES ASSOCIATED WITH OBTAINING PERMIT (MUNICIPALITY
* DELIVER COMPLETED PERMIT PACKAGE TO PROPER MUNICIPALITY,
C4NTINUED.ON NEXT PAGE
Page 5 of 6 NO. H6322-153309 Customer Copy
SPECIAL SERVICES CUSTOMER INVOICE - Continued Name: HARRIS Page 6 of 6 No. H6322-153309
INSTALLATION #3
(Confinued) LREE#111
SPECIAL NOTES:
' -1 OMER 'S F,'�R PAYNiENIT OF T
TH— : -- — THE PERM11T. ONCE REF�iNDS ON PFW��-T FF1--S AF —1�-:R 72 HRS OF PAYMEN'-T
E PERMIT IS PAID FOR, WORK ON THE PERMIT ASSEMBLY BEGINS
IMMEDIATELY. CANCELLATIONS WITHIN 72 HRS. WILL BE REFUNDED
Z:j,') OF INSTALL 93
(,'HARGES OF A MERCHANDISE & SERVICES
Policy Id (Pl):
A: 90 DAYS DEFAULT POLICY; jl SALES 1 AX'
TOTA1_i
BALANCE ME 1
D --p-, ot i esel ves the iightfolimit deny re turns. Please see the return policy sign in stores for details.'
E-911b OF ORDER No. H6322-153309
Page 6 of 6 No. H16322-153309 Customer Copy
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax (305) 756.8972
Inspection requirements for:
Windows, Doors, Skvlights or Fixed Glass (cladding)Permits
Upon issuance of permits for the scope of work involving the removal, changing and/or
replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding)
the permitholder or qualifier bearing his signature on the permit application shall abide
by the requirements of this department and comply with the following statement:
Upon obtaining window and/or door permits for the installation of same, it is the
responsibility of the permit holder to request window/door framing in -progress
inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims,
etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The
purpose for this inspection, is for the verification of conformance with Product
Approval (NOA).
Acknowledgement:
alifier/Owner Signature Date
Print Name
Vd
,36" ����
0A
30':,X RECEIVED.
IC4_. .
_ MAR 2 7 20i9 •.. • : . •
..
(A
BY DATE •....• ..• • •...•
7 ,-
1GEPF •• •. .. ......
36" X 80" • . • . • • • •
BLD, DEFT
SuB ••••••
,� . • • . ..
_ ;, v ALL I EUERAL • • •
STATE ANu t r INN,°{ ail L_S AND REGULAR,EPLACE Di ORS IN 3 OPENINGS ONLY.
NEW DOORS TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED.
OPENING
NO. WIDTH. HGT.
SQ.
FTG.
WIND
ZONE
OPENING
PRESSURES
POS. NEG.
PRODUCT
APPROVAL
(N.O.A. #)
DESIGN
PRESSURES
POS. NEG.
COMMENTS
1
36
80
20.00
4
38.2
-41.6
FL16708.2
65.0
-65.0
FRONT ENTRY - LSMI
2
30
80
16.67
4
40.1
-43.4
FL16708.2
65.0
-65.0
SIDE GARAGE - LSMI
3
36
80
1 20.00
4
1 38.2
-41.6
1 FL16708.2
1 65.0
-65.0
1 FAMILY ROOM - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT < 14 FT 1 IN
HARRIS RESIDENCE
945 N.E. 98TH STREET
MIAMI SHORES, FLORIDA
DOOR REPLACEMENT PLAN
01/09/2018 - 12:09pm inteml
Plan Sheet Store\Windows-Doors-Shutters\400 Wind Charts\ Reference\2017 Windload Charts References\2017 b FBC WIND CHART
6th EDITION FLORIDA BUILDING CODE (2017) ASCE 7-10 WIND VELOCITY - 175 MPH
`ASD' DESIGN PRESSURES FOR COMPONENTS AND CLADDING I
INTERIOR ZONE*PRESSURES
Mean
DESIGN PRESSURES (PSF) - Z NE 4
Roof
Tributary Area (Sq Ft V
10 30 40 5 `
-43.4
-41.6
-40.6
-39.
J15
+40.1
+38.2
+37.2
+36.
+3
1
-42.2
-41.440;
18 ft
_
+41.6
+39.7
+38.6
+37.9
+37.3
-46.2
-44.2
-43.1
-42.3
-41.7
20 ft
+42.6
+40.6
+39.5
+38.7
+38.1
-48.4
-46.4
-45.2
-44.4
-43.7
25 ft
+44.6
+42.6
+41.4
+40.6
+39.9
-50.3
-48.2
-47.0
-46.1
-45.4
30 ft
+46.3
+44.3
+43.0
+42.2
+41.5
-51.9
-49.8
-48.5
-47.6
-46.9
35 ft
+47.9
+45.7
+44.5
+43.6
+42.9
-53.4
-51.2
-49.9
-49.0
-48.3
40 ft
+49.2
+47.0
+45.7
+44.8
+44.1
-54.8
-52.5
-51.1
-50.2
-49.5
45 ft
+50.5
+48.2
+46.9
+45.9
+45.2
-56.0
-53.7
-52.3
-51.3
-50.6
50 ft
+51.6
+49.3
+47.9
+47.0
+46.2
-57.1
-54.7
-53.4
-52.4
-51.6
55 ft
+52.7
1 +50.3
+48.9
1 +47.9
1 +47.1
-58.2
55.8
-54.3
53.3=
_52.6,
60 ft
+53.6
+51.2
+49.8
+48.
+
EXTERIOR ZONOPRESSURES
Mean
DESIGN PRESSURES (PSF) - ZONE 5
f
Tributary Area (Sq Ft) 3
eiih
t
10 1 20 1 30 1 40 50
-53.6
-50.0
-47.9
-46.4
-45.2
&15 ft
+40.1
+38.2
+37.2
+36.4
+35.9
-55.7
-52.0
-49.8
-48.2
-47.0
18 ft
+41.6
+39.7
+38.6
+37.9
+37.3
-57.0
-53.1
-50.9
-49.3
-48.1
20 ft
+42.6
+40.6
+39.5
+38.7
+38.1
-59.7
-55.7
-53.3
-51.7
-50.4
25 ft
+44.6
+42.6
+41.4
+40.6
+39.9
-62.1
-57.9
-55.4
-53.7
.4--
30 ft
+46.3
+44.3
+43.0
2441.S,
-64.1
-59.8
-57.3
35 ft
+47.9
+45.7
+44.5
+ -
- 42=
-65.9
-61.5
-58.9
7.
.6
40 ft
+49.2
+47.0
+45.7
' 4. „
1_
-67.6
-63.0
-60.4
-58.5
- -
45 ft
+50.5
+48.2
+46.9
+45.9
+45.2
-69.1
-64.4
-61.7
-59.8
-58.3
50 ft
+51.6
+49.3
+47.9
+47.0
+46.2
-70.5
-65.8
-63.0
-61.0
-59.5
55 ft
+524.7
+50.3
+48.9
+47.9
+47.1
-71.8
-67.0
-64.1
-62.1
-60.6
ft
�'
+53.6
+51.2
+49.8
+48.8
+48.0
EXPOSURE C
ENCLOSED STRUCTURE, FLAT TERRAIN
INSTRUCTIONS FOR TABLE USE:
1. IDENTIFY THE ZONE OF THE OPENING 9 IOR-(ZONE 4)
URE BELOW LEFT OR INFOR ION PROVIDED Y- TH
MRH 5 60'
BASED ON Kd = 0.85
MRH = MEAN ROOF HEIGHT
(SEE BELOW)
OR EXTERIOR (ZONE 5) PER THE
�\1.1. ANY QUESTIONABLE: OP�IE _ ,TOBE- ONSI D THE MORE CRITICAL (EXTERIOR) ZONE
\[./IDENTIFY THE BUILDING M N.. VER _ TF,� T FROM THE LOWEST GROUND ELEVATION. IF
YF MEAN ROOF HEIGHT CANNOT E.I_ fIED, T PEAK (HIGHEST) ROOF HEIGHT.
2.1. ALWAYS ROUND UP RO�F y,EIG TO NE T LE VALUE.
2. VALID FOR ALL ROOF ES:_ FOIZySLO ES EE AN ENGINEER FOR REDUCTIONS.
CALCULATE THE TRIBUTARYiSRE. - OPE IN IN U STION AS THE GREATER OF (HEIGHT
WIDTH) OR THE SPAN LENGTH (HEIGHTf"_1A�VrifIVE WIDTH OF 1/3 THE HEIGHT (HEIGHT z / 3).
3.1. USE THE AREA BETWEEN STRUCTUIEWL' OPENINGS ONLY- THIS INCLUDES AREAS BETWEEN
STRUCTURAL MULLS, COLUMNS, ETC.
3.2. IF THE TRIBUTARY AREA OF AN OPENING CANNOT BE IDENTIFIED, THE SMALLEST
(10 SQUARE FEET) SHALL BE USED.
3.3. ALWAYS ROUND TRIBUTARY AREA DOWN TO THE SMALLER TABLE VALUE. FOR LARGER
TRIBUTARY AREAS THAN PUBLISHED, USE THE LARGEST PUBLISHED VALUE.
READ OFF POSITIVE AND NEGATIVE PRESSURES FOR USE AS REQUIRED BY THE LOCAL MUNICIPALITY
IN ACCORDANCE WITH CODE.
S. FOR SITUATIONS THAT REQUIRE Kd=1.0, TABLE VALUES ARE UNDER -DESIGNED BY A FACTOR OF
1.18. VERIFY Kd REQUIREMENTS WITH LOCAL MUNICIPALITY PRIOR TO TABLE USE.
ERAL NOTES:
l TABLES ARE TO BE USED IN CONFORMANCE WITH "ALLOWABLE STRESS DESIGN METHODOLOGY" PER ASCE 7-10
SECTION 2.4.1 AND CHAPTER 30 PART 1 OR 3, USING THE CRITERIA AS OUTLINED HEREIN.
/2. DESIGN IS BASED ON THE 3 SECOND GUST (WIND VELOCITY) FOR THE WIND VELOCITY & EXPOSURE SPECIFIED.
NA 'WORST CASE' CRITICAL CONDITIONS SHALL BE ASSUMED FOR SAFE PRESSURE RATINGS.
1. ASCE 7-10 RISK CATEGORY IS INDEPENDENT OF THIS RATING. FIND CATEGORY TO MATCH OR BE LESS
IN\2.THAN THE RATED LIMITING WIND VELOCITY ABOVE.
i 3-TOPOGRAPHIC FACTOR Kzt=1.0 FOR FLAT TERRAIN USE ONLY. NO HILLS SHALL BE NEARBY AREA.
4. INTERNAL PRESSURE COEFFICIENT (GCpi=+/-0.18) FOR USE WITH AN ENCLOSED STRUCTURE ONLY.
S. VERIFY USE OF Kd (DIRECTIONALITY FACTOR) WITH LOCAL BUILDING DEPARTMENT.
HVHZ = HIGH VELOCITY HURRICANE ZONE.
6. TABLES ARE FOR WALLS AND VERTICAL SURFACES ONLY.
7. THIS DOCUMENT IS A MASTER PLAN SHEET, NOT A SITE -SPECIFIC DOCUMENT.
8. THIS DOCUMENT IS ONLY VALID WITH AN ORIGINAL SIGNATURE & RAISED SEALED
OR DIGITALLY SEALED WITH CORRESPONDING LIMITATIONS.
9. THIS DOCUMENT ILLUSTRATES ALLOWABLE DESIGN WIND PRESSURES (ASD) AS LISTED. APPLICATION OF THESE
TABLES AND CORRESPONDING WIND VELOCITY, EXPOSURE, & OTHER COEFFICIENTS LISTED HEREIN SHALL BE
DICTATED AND VERIFIED BY THE GOVERNING BUILDING DEPARTMENT AND PERMIT HOLDER. NO WARRANTY FOR
APPLICABILITY OF THE USE OF THESE TABLES IS,01`91ESED HEREIN.
10. THIS SPECIFICATION DOES NOT- - FFER'A PROD 7 V CERTIFICATION. REFER TO ANY SEPARATELY
SUBMITTED TEST CRITERIA AND OTH R LS FOR-DESIG STALLATION INFORMATION AND APPLICABILITY
OF THESE TABLE VALUES WHICH IS TO B� VERj��I _I 1ERE' ACCORDANCE WITH GOVERNING CODES.
11. ADHERE TO ALL LOCAL IMPACT PR rid" DANCES.
12. NO CERTIFICATION IS OFFERED kOJ TH�+iALTEGRITY'QF„THE HOST STRUCTURE.
13. EXCEPT AS EXPRESSLY PROVIDED t EREu=t i-i jjppADDITI�bUtlb.••NtttA'L--CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.
INTERIOR ZONE(4) EXTERIOR ZON Q C00 `PtErGHT EXPLAINED LEAST HORIZONTAL C Ln m In z 0 v m
DIMENSION m D G)m 61 p m m G1 O,
a= 10% OF LEAST HORIZONTAL DIMENSION OR 40% OF M KROOF PEAK ROOF - z m O z C 3' >' 2 rii O
HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF LEAST HEIGHT 5 5 = m O Ll v ; -q _ = m A w m m X �l
HORIZONTAL DIMENSION OR 3FT. USE ZONE 5 IF AT ALL IN QUESTION. p O n D Z v rn Z .. (n z
CONSULT AN ENGINEER FOR A MORE SPECIFIC INTERPRETATION IF MEAN m r 2 -i �0 m n m > m O
REQUIRED. ROOF 2 5 ® = O Z O s 2 m n z-1 m- 3
MEAN EAVE HEIGHT 'T p 00 z m m 3 D m 0 "' D D
a a ROOFO ROOF '_�-,>>z0_12vz_ M [)
t t HEIGHT HEIGHT L• 1684 Fh opm Tr c H 9 s 4Hama O
•Zr-z;o �1-YOz��C m • M 90
O btnymi A7 2•Lln mi 1?
O /� 55 -4 z O •, Corn ,r z -d C7•c z U)
5 5 y a PLAN VIEW •4�z• �nmdy; Am m� 7e p z D
a O� COMPLEX \� vTm ^rnA=rmm� z �-n (-
ELEVATION ISOMETRIC CORNERS 5 5 p �° �' v
•• ••• • ••• • •
fA O o REMARKS GSS TSB
DATE 6TH EDITION FLORIDA BUILDING'CODE � ' wzo
D O INITISSUE GSS TSB 03/05/12 IPJEERIN
m 3 REV - ADJUSTED HEIGHTS GSS TSB 04/09/12 2017 '�' •' PF ESSO zREV 2014 FBC DGM TSB 06/10/15Q UPDATES, 2017 FBC FLB FLB 12/17 ASCE 7-10, CHAPTER 30 CORPORATE OFFICE160 SW 12th AVENUE, SUITE 106DESIGN LOADS FOR COMPONENTS& CLADDING•• • • • �� � I = MASTER PLAN SHEET • • • • ?E ESE cH, FL 33442 Gi THIS DOCUMENT IS THE PROPERTY OF ENGINEERING EXPRESS, • • • P: (54) 354-0660b F: (954) 354-0443 vAND SHALL NOT BE REPRODUCED IN WHOLE OR PART WITHOUT E:T�4&CTH#9885
O a WRITTEN CONSENT OF ENGINEERING EXPRESS. ALTERATIONS, 1 • • • • • • • • m 0 5
ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT ASCE 7-10 ��� •E: HELLS@NNGINEBRINGEXPRESS.COM p Z m f 16" v
QPERMITTED AND INVALIDATE OUR CERTIFICATION. ENGINEERINGEXPRESS.COM n _< W m
BCIS Home Log In User Registration Hot Topics I Submit Surcharge Stats & Facts I Publications 1 FBC Staff ! BCIS Site Map Links Search
Product Approval
�. •c.. USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL16708-R8
Revision
2017
Approved
• •
• •
•••••
••••••
•
•
•
• • •
•
••••••••
•• ••
••••••
•
• •••••
••••
• ••
•••••
JELD-WEN
••••••
••• •
••i••�
3737 Lakeport Blvd
••••••
•0
••••••
Klamath Falls, OR 97601
•
(800)535-3936
• • •
•
fbcl@jeld-wen.com
• •
• •
• • • • • •
••••••
• •
•
• •
•• •
• ••
• •
Jason Kantola
�•:••�
fbcl@jeld-wen.com
JELD-WEN Corporate Customer Service
3737 Lakeport Blvd.
Klamath Falls, OR 97601
(800)535-3936
customerserviceagents@jeld-wen.com
Exterior Doors
Swinging Exterior Door Assemblies
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Hermes F. Norero, P.E.
Evaluation Report
Florida License PE-73778
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Locke Bowden
El Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Standard
TAS 201
TAS 202
TAS 203
Year
1994
1994
1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL #
Florida Licensed Professional Engineer or Architect
FL16708 R8 Eouiv ASTM E84 Equivalency Letter SS 2017-08-31 IZ
Method 1 Option D
10/02/2017
12/12/2017
12/18/2017
02/13/2018
• •••• ••••••
Model, Number or Name I Description • • • • • •
• •
••••••
16708.1 A Design Pro / Smooth Pro / Studio Single (X) Impact Opacfu �D (Yr 3-0 x00 :6-C prod 3-0 x-8-0•
Fiberglass Inswing and Outswing
I---.._..--- ---------- _._..... ...... _.._ .. --- - -. •_•-� •-•.••_•. •----• . _..._.... • • •-• .
Limits of Use Installation Instructions••• •.; •.....
Approved for use in HVHZ: Yes FL16708 R8 II A01087-1.A.X,•OPQ SS 2417-02-09.odf••
Approved for use outside HVHZ: Yes Verified By: Hermes F!Norfero, P.E. 73778 •
Impact Resistant: Yes Created by Independent Third Party:liass • • • •• • •
Design Pressure: N/A Evaluation Reports ; .0. • • • •
Other: FL16708 R8 AE P R466S.1 SS 01:-110-117.n_df • •
Created by Independent Third Party: v(6 •
16708.2 B Design Pro / Smooth Pro I Single (X) Impact Glazed Door 3-0 x 6-8 and 3-0 x 8-0
Fiberglass Inswing and Outswing
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other:
Fiberglass
Installation Instructions
FL16708 R8 II A01087 A X. QL7 S 016-08 6.od
Verified By: Hermes F. Norero, P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
FL16708 R8 AE PER4438.1 SS 2017-11-17.pdf
Created by Independent Third Party: Yes
Inswing and Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16708 R8 II A010873A XX OPO SS 2017 OZ 09 df
Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778
Impact Resistant: Yes Created by Independent Third Party: Yes
( Design Pressure: N/A Evaluation Reports
Other FL16708 R8 AE PER4664.1 SS 2017-11-17 df
Created by Independent Third Party: Yes
16708.4 D Design Pro / Smooth Pro Double (XX) Impact Glazed Door 6-0 x 6-8 and 6-0 x 8-0
Fiberglass Inswing and Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16708 RE II A010874A XX. GLZ SS 2016-08-26.pdf
Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: FL16708 R8 AE PER4440.1 SS 2017-11-17.pddf
Created by Independent Third Party: Yes
16708.5 m E Design Pro / Smooth Pro / Studio Single with sidelite(s) (X,O/ O,X/ O,X,O) Impact Opaque Door
Fiberglass 9-0 x 6-8 and 9-0 x 8-0 Inswing and Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16708 R8 II A010875A OXO, OX OPO SS 2017-02-09.pdf
Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. 73778
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: FL16708 R8 AE PER4665.1 SS 2017-11-17.pdf
Created by Independent Third Party: Yes
f _
16708.E F Design Pro /Smooth Pro Fiberglass
j
Single with sidelite(s) (X,O/ O,X/ O,X,O) Impact Glazed Door
9-0 x 6-8 and 9-0 x 8-0 Inswing and Outswing
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16708 R8 II A010876A OXO. OX GLZ SS 2016-08-26.�df
Approved for use outside HVHZ: Yes
Verified By: Hermes F. Norero, P.E. 73778
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other:
FL16708 R8 AL PER4442.1 SS 2017-11-17.{Ldf
Created by Independent Third Party: Yes i
16708.7 G Design Pro / Smooth Pro / Studio Double with sidelite(s) (XX,O/ O,XX/ O,XX,O) Impact Opaque
Fiberglass Door 12-0 x 6-8 and 12-0 x 8-0 Inswing and Outswing
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ
Impact Resistant: Yes
Design Pressure: N/A
Other:
Installation Instructions
FL16708 R8 II A010877A OXXO. OXX OPO SS 2017-02-
Yes 09, odf
Verified By: Hermes F. Norero, P.E. 717.7"
Created by Independent Third Party!Yes •
Evaluation Reports e • • •
FL16708 R8 AE PER4At.1 SS 201Z?11,1:.Dd • •
Created by Independent T:Mf Party: Yes • • • • • • • •
16708.8 H Design Pro / Smooth Pro Double with sidelite(s) JXX,4/•O,XX/:?4X,O� Impact Glazed
Fiberglass I Door 12-0 x 6-8 and 1240•x @-0 Insw#ng and Outsvoing • • _
Limits of Use Installation Instructions -
Approved for use in HVHZ: Yes FL16708 R8 II A010$-78V)XXO, OXX GL`ZSS 20iS-•(i�•
I Approved for use outside HVHZ: Yes 26. pd • • • • • • • •
Impact Resistant: Yes Verified By: Hermes FNorero, P.E. ii377& • • • • 0 r •
Design Pressure: N/A Created by IndependectThisd PartyyYes •• . •
Other: Evaluation Reports • 00' ; • • • ; • • • • ;
FL16708 R8 AE PER4444.1 SS 2019-&-
Created by Independent Third Party: Yes
The State of Florida is an AA/EEO employer. Sopyrioht 007- 013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click berg_.
Product Approval Accepts:
eCk M
Credit Card
Safe
//aA\\ BUILDING DROPS
A Perfect Solution in Every Drop
Certificate of Authorization: 29578
April 27, 2015
398 E. Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
TO: Whom It May Concern
FROM: Hermes F. Norero, P.E.
40660
Registered Florida Professional Engineer #73778; .'
• • • •
• • • • • •
•
......
.. ..
......
MANUFACTURER: JELD-WEN, inc. •••:••
3737 Lakeport Blvd. • • • •
• •
••••
.••
Klamath Falls, OR. 97601
..:Go •
Dear Sir (Madam), ;••;•;
•
•
. .
. .
......
To the best knowledge, tothe'currvt
:•"•:
of my the above -mentioned product conforms
••
edition of the Florida Building Code.
••••
Please note that I do not have, nor will I acquire, a financial interest in any company
manufacturing or distributing the product(s) for which the reports are being issued.
I also do not have, nor will I acquire, any financial interest with the Laboratory that
performed the test(s), or with the Engineer witnessing the test(s) and sealing the test
report(s).
Respectfully submitted, ``011111iiir,�,i
7
411
0.� L pP.4
��/ONA ,E�`���.
f1111
Digitally signed by Hermes F. Norero, P.E.
Reason: I am approving this document
Date: 2015.04.27 20:14:19-04'00'
Hermes F. Norero, P.E.
Florida Registered Professional Engineer #73778
Page 1 of 1
BUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization:29578
August 24, 2017
trel
Whom It May Concern
398 E. Dania Beach. Blvd
Suite 338
Dania Beach, Fl- 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
FROM: Hermes F. Norero, P.E.
r•••
Registered Florida Professional Engineer #73778 00*0 •
*00000
• ..
MANUFACTURER: Jeld-Wen •••:•• •• •• ••••//
3737 Lakeport Blvd. ' •Does `
......
Klamath Falls OR 97601 • • •
• •
••/••• ••• / •/•1•
This document shall serve to state that Jeld-Wen products tested in accordance with ASTMT;42b5 as per the051h Edition:'
Florida Building Code shall be qualified for the requirements of the 6th Edition Florida Build 0g EoJle. s 0 • •..0
.•/••.
The testing on the products complies with the requirements specified within the ASTM E84%? standard, l%quiredvy �+
the 61h Edition Florida Building Code. This standard is listed under Chapter 35 of the current Florida Buildfr?gCode and
titled "Standard Test Method for Surface Burning Characteristics of Building Materials".
ASTM E84-13 has been reviewed and determined to be technically equivalent to ASTM E84-05. All test results meet or
exceed requirements of the 6th Edition Florida Building Code.
Respectfully submitted,
F.
7�.
9
N
C
/� ••••••�� �'• Digitally signed by Hermes F. Norero, P.E.
NA i�«�� Reason: I am approving this document
Date: 2017.08.31 09:51:27-04'00'
Hermes Norero, P.E.
Florida Registered Professional Engineer #73778
Certification of Independence:
Please note that I do not have nor will I acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being
issued. Also, I do not have nor will I acquire a financial interest in any other entity involved in the approval process of the listed
product(s).
Page 1 of 1
JELBrWEN.
WI-NDOWS &- DOORS
DESIGN PRO / SMOOTH PRO FULL LITE
IMPACT APPROVED
FOR USE IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ)
GENERAL NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA
BUILDING CODE (F8C), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING:
• TAS 201-94
• TAS 202-94
• TAS 203-94
2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY OR 2X FRAMING AS A MAIN WIND FORCE
RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE
FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF
INSTALLATION.
3. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR
A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED
HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS
DOCUMENT.
4. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT
RESISTANCE.
5. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 6 FOR GLAZING DETAILS.
6. FULL LITE APPROVAL COVERS USE OF FRACTIONAL GLAZING, INCLUDING INTERNAL GRID, BLINDS BETWEEN
GLASS, DECORATIVE, AND EXTERNAL WROUGHT IRON AND RADIUS (SHAPED) LITES
7. NOTE: AFCO H-497 SILL MEETS WATER INFILTRATION AT WATER TEST PRESSURE (WTP) OF 9.75 PSF.
REMAINING SILLS NOT RATED FOR WATER INFILTRATION. IF AUTHORITY HAVING JURISDICTION REQUIRES THAT
PRODUCT MEETS THIS REQUIREMENT, PRODUCT SHALL BE USED WHEN INSTALLED AT LOCATION PROTECTED BY
OVERHANG SUCH THAT OVERHANG (OH) RATIO = OH LENGTH> OH HEIGHT 15 2: 1.0
TABLE OF CONTENTS
SHEET
REVISION
SHEET DESCRIPTION
1
B
TYPICAL ELEVATIONS, DE51GN PRESSURES, AND GENERAL NOTES
2
B
TYPICAL ANCHOR LAYOUTS AND NOTES
3
B
OPTIONAL 2X BUCK ANCHORING DETAILS
4
B
VERTICAL ASSEMBLIES
5
B
HORIZONTAL ASSEMBLIES
6
B
GLAZING DETAILS
7
B
WOOD SUBSTRATES
8
B
CONCRETE SUBSTRATES
9
B
COMPONENTS & BILL OF MATERIALS
10
8
COMPONENTS
37 1/2" MAX.
O.A. WIDTH
G I
s a
�
M
3
i
b O
m�
a
u
Z v LL
e ACTIVE
o
2 '
3 z
3 ? Q
O
5 ®
3
s z
z
=
O z
3 a 5
d a a
TYP. ELEVATION 1
6'-R' 000R HEIGHT
6 7
4 9
a 9
4 4
E
37 112" MAX.
TYP. ELEVATION 2
1 R'-0' DOOR H TI
NOTE:
DOORS SHOWN ABOVE MAY BE LEFT
OR RIGHT HAND OPERATING DOORS.
•• ••• • • • • • ••
• •• • • • • ••• •
MAX. OVERALL
DESIGN PRESSURE (PSF)
NOMINAL SIZE
MISSILE
CONFIGURATION
IMPACT
INSWING
OUTSWING
WI11IT61
el "HIT
RATING
•
POS•
POS.
G.
X
'-Oi
fi'-8" •
�Se
.65A•
65e�
1 & SMI
X RADIUS
-
��
•6i`
X
3'-0"
8'-0"
50A
50
SOA
50
LMI & SMI
A: SEE GENERAL NOTE 7, SHEET 1, FOR WATER INFILTRATION APPROVED SILLS.
B: DESIGN PRESSURE L"TiD Tit +/-50 6SF 141T%IUSF•04=jU VRDWA&E, ITEM N27
• • • • • • • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
PREPARED BY
/r/6� \\),,
BUILDING DROPS, INC.
394E �FEIIF RFAil181 �'D., STF. 33R
. N REFCII. rL f 3lIJa
'a1lnSi1]ii i)RR
W F3.,ww�.v buildinpd•pp;.con
ti
LLJ
-o
m
W
zH
m0
ao
l7 0
�Z
oaf
a
W J
o
_
O Qcc
g x
I'
N
� Q
Z Z
m g
0 W
Y
F L
at>LJ
Qa
Z
-j
W N
I+M
O} N
F�
I— �
W
H=
a
Fi
REMARKS
I BY1 DATE
dd ADA sill, MP Luck, Radius
LL.
GL 6/23/14
Add GU Hardware
I LS 8/24/16
Digitally signed by Hermes F. Norero. I
Reason: I am approving this document
Date: 2016.08.26 19:14:23 -04'00'
DATE: 02.05.14
DWG. Y: I CHK. Y:
GL TJM I SS MSS
I SCALE: NTS
DWG. a: A010872A
SHEET: OF10
1
INSTALLATION NOTES:
1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN.
2. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE
SHIM STACK TO BE 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.
3. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO
STUCCO, FOAM, BRICK VENEER, AND SIDING,
4. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL
OR HAVE A CORROSION RESISTANT COATING, AND SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
5. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR
JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE
SHELL OF BLOCK.
6. FOR 2X STUD CONSTRUCTION, ANCHORING OF THESE PRODUCTS SHALL BE THE SAME AS FOR 2X BUCK
CONCRETE/MASONRY CONSTRUCTION.
7. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE
FOLLOWING PROPERTIES:
A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55.
B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.
C. GROUT -FILLED CMU- UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH
OF 2000 PSI AND GROUT CONFORMS TO ASTM C 476, MINIMUM GROUT COMPRESSIVE STRENGTH OF 2000
PSI.
D. HOLLOW BLOCK CMU - UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH
OF 2000 PSI.
8. SEE SHEETS 7 AND 8 FOR MORE DETAILS OF THE INSTALLATION REQUIREMENTS, INCLUDING ANCHOR
LOCATIONS, EDGE DISTANCES, EMBEDMENTS, AND SHIM SPACING.
9. OPTIONALLY, ANCHORS CAN BE PLACED IN NARROW SECTION OF HEAD OR JAMB AS LONG AS MINIMUM
EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED,
ANCHOR TABLE
61" DOORS
0" DOORS
ANCHOR TYPE
ANCHOR
SIZE
SUBSTRATE
MIN.
EMBEDMENT
MIN.EDG
DISTANCI
MAX. O.C.
AAX. O.C.
SPACING AT
ACING AT
JAMBS
JAMBS
WOOD SCREW
010
2X WOOD BUCK
1-1/2"
3/4"517-1/2"17-1/4"
-1/4"
OR FRAMING
ITW TAPCON
3/16"
CONCRETE/CMU
1-1/4"
2-1/2"
-1/4"
ELCO ULTRACON
1/4"
CONCRETE/CMU
1-3/8" - CONC.
1"
1-1/4" - CMU
ITW TAPCON
3 16"
CONCRETE CMU
1-1/4"
1".3/8"
82
2- R9 X 2 1/2" PFH
SCREWS
DETAIL D2
2- s9 X 2 1/2" PFH
TYP. HOPPE/GU
PFH SCREWS
MULTI -POINT SHOOT BOLT
^•
PLATE LOCATION V••
DETAIL B2
(RH PLATE SHOWN)
TYP. HOPPE/GU
1- BOTTOM SHOOT
D2
MULTI -POINT SHOOT BOLT
BOLT PLATE
PLATE LOCATION
SILL SECTION VIEW
(.-\ HEAD SECTION VIEW
INSWINGSHOWN OUTS -SIMILAR
Z INSWINGSNOWN OUTSWINGSIMILAN
SEE DETAIL
- SEE DETAIL DE
37 1/2" MAX.
O.A. WIDTH
3" TYP-. —
C2 C2 3"11TYP.
r�
F
x
L7 w
m
m
< s
¢
z�LL
9
C)
h Z a
oz N
O
Z II liz 11 1 �
VP. ANCHOR LAYOUT
NOTE:
NO ANCHORS REQUIRED AT THE SILL FOR SINGLE DOORS (X) ONLY.
•• •••
• ••
•• •••
• •
• •
••
• • •
• • •••
• • •
••
•
••
• •
•••
•
•••
•••
• • • •
• •
• • • •
•
• • • • • •
• • • • •
• •
• •
• • •
• • • •
PREPARED BY: '
BUILDING DROPS, INC.
3Js E. DANIA SI ACII EI VD, STE. 3?3
A 1.11
f ll:(9Sf1399Fi>8
fa} 1?Sal�.l�.r]3a
WLa: www.buile•nxe,op,.con
L LA
Lu
F-
S
Z
> m $
CL 0 Q
W LL d
=s Ln
3�=
~ 4 ~
O
< a W
O
M g
U
Q
O\4
a=
�
m
(Sa
U
w Z
„
� Q
r
W;
u
d
~7
REMARKS
BY
DA-
Ldd ADA sill, MP Luck, Radius LL.
GL
/2:
Adtl GU Hardware
LS
8/21
,11111IlJJJJ
DATE: 02.05.14 1
GL/TJM I SS/IV
SCALE: NTS
DWG. a: A010872A
SHEET: C
2
. . . . .
. .• .. . . .
... . . . ... . .. ..
0
11 1 \
INTERIOR EXTERIOR
(—J--� OPERABLE HEAD
4 OUTSWING SHOWN - INSWING SIMILAR
INTERIOR
Q10
EXTERIOR
OPERABLE ADA SILL
4 INSWING/OUTSWING
ENDURA HC15000
11
B INTERIOR EXTERIOR
io
OPERABLE SILL
4 OUTSWING
OPTIONAL AFCO A-117
EXTERIOR
4
I
OPERABLE SILL
4 INSWING
ENDURA ZAIL4565F
w
OPERABLE SILL
4 INSWING
AFCO A-276/P-2000
11
9 INTERIOR EXTERIOR
f
OPERABLE SILL
4 OUTSWING
OPTIONAL ENDURA ZOBL4565F
11
5 INTERIOR / EXTERIOR
1^
Q OPERABLE SILL
'\A OUTSWING
AFCO J-2297
11
7 INTERIOR EXTERIOR
�T' O
—Ifl- O
r7--� OPERABLE SILL
\\A OUTSWING
OPTIONAL AFCO H-497
•• •••
• •
• •
•
••
• ••
• •
• • •••
•
•• •••
••
• •
•
••
.. ...
.
••.
.
.
. 0..
. .
• • • •
• •
• • • •
•
•
• • •
• •
•
• •
•
•
•• •
• •
• •
•
••
go:
••• • •
• •
•••
0
PREPARED BY
1r1o,^—)\\\
BUILDING DROPS, INC.
399E. DAN'A BEACH —D.. STE. 338
;1— MACI3.1'I. 31UUA
rle (Bsa uo-3.xnn
CAI I-1]i4. —
wF3x.. UUNdinxdrou:.:o.n
W
,o
m N
Q
O W
Fn
o
Dim
4 >
W
w LL
_ Cc
DO
m
Q =
O`t
Lu
mg�
Sc U
v)
y
oa
Q
J
�yr
G
Q
O
W
K
y
O
>
�x
w s
F
�DA sill, MP lock, Radius LL' GL I06/23/14I
Add GU Hardware LS 8f24/16
vAVtmrw0,A CONMNIa MH-llNG O R0711ER
A.MNG ON3,AODItpNS, HNSHt1N TING.ONU111Ex
MM.tINGS rO YNIS WCI3MEN1 AI!E NOi V•ENMIYLkU nM1'U
al�OAtF OUR CtxtIEKATION.
DATE: 02.05.14
GL/TJM SS�NISS
SCALE: NTS
DWG. a: A010872A
SHEET: OF10
INTERIOR
HINGE SCHEDULE
DOOR HEIGHT
QUANTITY
6' 8"
3
8' 0"
4
INTERIOR
1- 119 X 2-1/2" PHILLIPS
\ FLATHEAD WOOD SCREW
3-#9 X 3/4" PHILLIPS
O FLATHEAD WOOD SCREWS
EXTERIOR EXTERIOR
4- #9 PHILLIPS FLATHEAD WOOD SCREWS
17 USE 3/4" LENGTH FOR 6'-8" DOORS
USE 1" LENGTH FOR 8'-0" DOORS
LOCK JAMB HINGE JAMB
'--5j OUTSWING SHOWN -INSWING SIMILAR 5 OUTSWING SHOWN -INSWING SIMILAR
HOPPE
13 - #8 X 1 3/8" PFH (6'-8" UNITS)
9 - #9 X 1 3/4" PFH HOPPE 15 - #8 X 1 3/8" PFH (8'-O" UNITS)
3 - #8 X 2' PFH COMES W/ HARDWARE
8 -#9 X 2 1/2" PFH W/ HARDWARE W/ STRIKE HARDWARE GU
W/ STRIKE HARDWARE (6'-8" & 8'-0" UNITS) 1- MPL STRIKE PLATE 12 - #8 X 1 1/2" PFH (6'-8" UNITS)
4- MPL STRIKE PLATES GU 14 - #8 X 1 1/2" PFH (8--0" UNITS)
2 - #9 X 5/8" PFH 21
20 W/ STRIKE HARDWARE
HINGE DETAIL AT JAMB:
PLACE #9 X 2-1/2" PFH SCREW NEXT TO WEATHERSTRIP
EXTERIOR
t- ,
INTERIOR ro
MULTI -POINT LOCK JAMB
5 OUTSWING SHOWN - INSWING SIMILAR
ROCKWELL HARDWARE
EXTERIOR
INTERIOR
MULTI -POINT LOCK JAMB
5 OUTSWING SHOWN - INSWING SIMILAR
HOPPE/GU HARDWARE
3 - 48 X 1 1/2" PFH
1-REINFORCEMENT
SHOOT STRIP
0_
Y i ,
gp� _
1
GU MULTI -POINT LOCK
5 TOP/BOTTOM REINF. PLATE -ACTIVE PANEL ONLY
4 - #8 X 1 3/8" PFH
1 - REINFORCEMENT PLATE —� o
HOPPE #2512296
0
o
• •• • • • • •• •
•• ••• liCFPPE•MULTI-POINT LOCK
5 TOP REINFORCEMENT PLATE - ACTIVE PANEL ONLY
•• ••• • ••• • •
PREPARED BY:
//r(l3\)l\l\
BUILDING DROPS, INC.
3^B E. —41A BEACH 3tVD.. STE. 338
DAf`IIA:—CI,, 4 ]31M3C
PH I85a11?}p.l]B
FAM 11141 A)1R
WBB: •.vw-.v.Bui!dirRd•oD;.co•r.
y
o�
kf
O
mp m
Q 00
a e a
K J
�
=
FI- El.
OQ'n Lu
m�
5
�v Q
a (7
° Z
1-
a— Z N
Z«
C)g
w
w
�
a
w,-
REMARKS
I BY DATE
dd ADA sill, MP Link, Radius
tt.
GL G/23/14
Arid GU Hardware
IS R/2d/1G
DATE: 02.05.14
DWG. Y: I CHK. Y:
GL T1M SS/MSS
SCALE: NTS
DwG. #: A010872A
.••.... 5
hl
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
1" MAX. 1/2" AIRSPACE
INTERIOR
EXTERIOR
1/8" ANNEALED GLASS
z
0.090"SOLUTIA PVB INTERLAY
m
1/8" TEMPERED GLASS
DOW 1199 SILICONE
DOW 995 SILICONE
22
REDI-SEAL
DOW 1199 SILICONE
1�6'-8"
GLAZING DETAIL
1
201/2" MAX. D.L.O. WIDTH
621/2" MAX. D.L.O. HEIGHT
1/2" AIRSPACE
INTERIOR F/8"
TERIOR
-1/8" ANNEALED GLASS
SOLUTIA PVB INTERLAYER
z'
� �Q F m TEMPERED GLASS
995 SILICONE
� REDI-SEAL
tom'-0" GLAZING DETAIL
6 201/2" MAX. D.L.O. WIDTH
78 1/2" MAX. D.L.O. HEIGHT
1/2" AIRSPACE 1 MAX. 1/2" AIRSPACE
INTERIOR EXTERIOR INTERIOR EXTERIOR
1/8" ANNEALED GLASS 1/8" ANNEALED GLASS
0.090" SOLUTIA PVB INTERLAYER
z m 0.090" SGP INTERLAYER
rn 1/8" TEMPERED GLASS z m BY DUPONT
a N 1/8" TEMPERED GLASS
N� DOW 995 SILICONE a—DOW 995 SILICONE
.. 23
t� FLUSH GLAZE DETAIL
237/8" MAX. D.L.O. WIDTH
78 7/8" MAX. D.L.O. HEIGHT
— DO W 995 SILICONE
GLAZING DETAIL
1,6
f FOR OVAL, SUNBURST, AND ROUND TOPS
IN 6'8" UNITS AT DP+/- 65 PSF ONLY
•• •••
• •
• •
•
••
• ••
• •
• • •••
•
NOTE:
• •
• • • • •
• •
• •
• • •
•
•
•
FRACTIONAL GLAZING, INCLUDING INTERNAL GRID, BLINDS
•
•
••
BETWEEN GLASS, DECORATIVE, EXTERNAL WROUGHT IRON
AND RADIUS ARE APPROVED IN ALL GLAZING DETAILS SHOWN
ABOVE.
•• •••
•
•••
•
•
• • ••
•
• • •
•
• •
••• •
• •
• •••
•
A.
•
• •••
•
•
• • •
• •
• •
• • •
• •• ••
•
• •
••
••
PREPARED BY: "
//01\\\
BUILDING DROPS, INC.
399 E. DAN!A BEACH BLVD, STE, MS
R3u9a
rak195a1)aa A)1R
W EA'. ww•x Duildl"Rd'nV-_.on
W
F•
. p m
�
p
a
4 Q W
Q
^ a =
LL
U Ln
x
[D
O °- 5
V)
a -
z:
o
0
W �
Q
�
w-
F
►-1
REMARKS
I BY DA
Ad ADA sill, MP Wck, Radius LL
I GL 6/2
Add GIIHardware
LS 8/2
wnD SHI t nor BE: RERRCDUDED (IW HOLE oB IARI
mwur W IDTRN CONRRHT x R— Nc D-5. INC.
a.rcR.,r,unS, aourTloRs. Hwrwwnnnc, on o3rnB
nRRwn ro nEn oonnnEnr AnE «<3r nBBa*reunxu
%t`ttiiLLillf///
DATE: 02.05.14
DWG. Y: CHK. Y:
GL TJM SS/MSS
SCALE: NTS
DWG. u: Ani n5t7) A
A
MIN.
EDGE DIST.
SEE TABLE SHEET 2
ow
C
w J 2X WOOD BUCK
Z_DO
�w
E>
c � n
WOOD ANCHOR
SEE TABLE ON SHEET 2
HEAD (TYPICAL)
7/ OUTSWINGSHOWN- INSWINGSIMILAR
lei
►F����������o�-�� I
OPERABLE SILL
7 OUTSWING - NO ANCHOR REQUIRED
AFCO J-2297
ILILUM
WOOD BUCK
OPERABLE SILL
7 OUTSWING - NO ANCHOR REQUIRED
AFCO A-117
OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW
SECTION OF HEAD OR JAMB AS LONG AS MINIMUM
EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED.
2X WOOD BUCK
NN I
WOOD ANCHOR
o F SEE TABLE ON SHEET 2
E>
0.28"
MAX.
SHIM
MIN. EMBED.
SEE TABLE SHEET 2
SILICONE
`2X WOOD BUCK
JAMB (TYPICAL) OPERABLE SILL
7 OUTSWING SHOWN - INSWING SIMILAR 7 INSWING - NO ANCHOR REQUIRED
ENOURA ZAIL4565F
SILICONE
SILICONE
2X WOOD BUCK 2X WOOD BUCK
OPERABLE SILL OPERABLE SILL
7 INSWING - NO ANCHOR REQUIRED 7 OUTSWING - NO ANCHOR REQUIRED
AFCO A-276/P-2000 AFCO H-497
C� SILICONE SILICONE
2X WOOD BUCK • • • • • • -X'%-D BUCK
g OPERABLE SILL _
7 OUTSWING - NO ANCHOR REQUIRED
ENDURA ZOBL4565F
1 -OPERABLE AUA SI4 .
71V'WIN /OUTSWING:NO eHORREQUIRED• •
• • 6NDUV HCI � • • •
••• • • • • ••• •
PREPARED BY:
n
BUILDING DROPS, INC.
3?B E. DAN:P BEACH ftl V.�.. 5'E. 338
anwn l+EnaJ. �:. 3-ia�i
rn. �?snLlonRna
EAklnSil]Ji J)3R
wEB. w»�.vmiemnRd•w;.cu•n
Ln
w
Q
I-
I -
En
6]
Ln
0
H
i
Ad ADA Sill, MP Lock, Radius LL GL /2:
Add GU Hardware LS 8/2,
U O UC
WIND SHALL NOT BE CONSENT
BUILD
DWHOLE ON 1.
-RATWITHOUT DNS,
AD CONSENT p� gC IDING D R MI �i
5, ADDrtION1.'lIOI4iGN*INO, ON OIiM
raAR.,�rs°�.NDD�„MEN oE.
``1111111111/j7
i
v TA( a
Al. NO 11
DATE: 02.05.14
DWG. Y: CHK. Y:
GL/TJM I SS/MSS
SCALE: NTS
DWG. P: A010872A
SHEET: OF 10
7
• •• •• • • • •• ••
••• • • • ••• • •
MIN.
lx WOOD BUCK
EDGE DIST.
w
(OPTIONAL)
SEE TABLE SHEET 2
N
4• .
vWsi
z o
w
CONCRETE ANCHOR
SEE TABLE ON SHEET 2
w
CONCRETE/
w J
MASONRY
/
z a
BY OTHERS
ED
I WOOD BUCK
(OPTIONAL)
.. o
o<,
CONCRETE ANCHOR
SEE TABLE ON SHEET 2
HEAD (TYPICAL)
8 OUTSWING SHOWN - INSWING SIMILAR
SILICONE
d d.
4 d
4
CONCRETE/
MASONRY
BY OTHERS
OPERABLE SILL
8 OUTSWING - NO ANCHOR REQUIRED
AFCOJ-2297
SILICONE
d d
4 d
4
CONCRETE/
MASONRY
BY OTHERS
OPERABLE SILL
OUTSWING - NO ANCHOR REQUIRED
AFCO A-117
E> OPTIONALLY, ANCHOR CAN BE PLACED IN NARROW
SECTION OF HEAD OR JAMB AS LONG AS MINIMUM
EMBEDMENT AND EDGE DISTANCE ARE ACHIEVED.
SILICONE
l�r
CONCRETE/
MASONRY
BY OTHERS
MAX,
I-}-- MAx.
SHIM
CONCRETE/MASONRY BY OTHERS
MIN. EMBED.
SEE TABLE SHEET 2
JAMB (TYPICAL)
OPERABLE SILL
OUTSWING SHOWN - INSWING SIMILAR
8
INSWING - NO ANCHOR REQUIRED
ENDURA ZAIL4565F
SILICONE
d d
4 d
a
CC
IM,
BY
[� OPERABLE SILL
8 INSWING - NO ANCHOR REQUIRED
AFCO A-276/P-2000
SILICONE
d d
4 d
O
CONCRETE/
MASONRY
BY OTHERS
OPERABLE SILL
8 OUTSWING - NO ANCHOR REQUIRED
AFCO H-497
SILICONE SILICONE
[4
4 . • • • •4 • • • :d �. • • •d
CONCRETE/ • • •. . . . • • •' • CONCRETE/
MASONRY • • • • • 0 • • • MASONRY
BY OTHERS BY OTHERS
(� OPERABLE SILL 1�OPERABLE SILL
8 OUTSWING - NO ANCHOR REQUIRED • • :8 OUTSWWG/jj WING - N0jkNCHOR REQUIRED
ENDURA ZOBL4565F • • ENDIiRA HCIWVDO • •
do • . •
. . .. . . . . .
• • ••• • ••• •.
••• • • • • ••• • •
• •• •• • • • •• ••
PREPARED BY
n
BUILDING DROPS, INC.
399 E. DANIA BEACH BI VD., STE, 33A
0AILABLACH . 10.
195413M F3Jq
FAX
1 S4 744 1738
w a .Hann a oPs co,.
m rn o
j
N
w
ELI�
Fo„
o m
~
W
cL
a
an
O�
Fes—
2
U
�
Q4
t/1
a
Lu
z:
cc
W'
L�
Uy"L
Z
W><
r=
ti
REMARKS
BY DATE
dd ADA sill, MP Lock, Radius
LL
GL 6/23/14
Add GU Hardware
LS R/M/16
AND Stull. NOT BE REVROOUCEU IN WHOLE OR 'All
�JTwm wanes T,0NSI or LIGHT r, Dgays, rvc.
A4MOON5,ADDITIONS, 1ARE W11," Oq D'D fl
mnxxiHcs ;D - I DATE
DOE, 1 ARE Har vtxmnrED AND
oATT; aIR EERn:rnnr,H.
`
DATE: 02.05.14
DWG. Y: I CHK. Y:
GL TJM 1 SS MSS
_...._......_........--
SCALE: NTS
DWG. m: A010872A
SHEET: OF10
8
20 ROCKWELL MULT-POINT LOCK
O
0
0
O
0
0@00
°
D
O
^^ O
cD o
0 °
0 no
0
O o n
u Q.
p 0
HANDLE
HEIGHT
a
(=>o D
O
0
° 0
0
e
O
.79"
21 HOPPE MULT-POINT LOCK
W/ SILL SHOOT BOLT PLATE #2098911
O�
HANDLE I
HEIGHT
aG o O
K. 1 0 O
1
n 0
0
0.63"
--1 1.65" 1—
27 GU SECURY S-BOLT MULTI POINT
T If
.• ... . ... • .
V. • • • • • •
. . ... . ... .
. ..... . ...
. •• .. . . • .. ••
.... . . ... • •
PREPARED BY:
BUILDING DROPS, INC.
398 E. DAN!A 8EACN BI VD.. STE. 338
iA BEAfII. Et 3301a
rN. l9sar3^�xalx
-AX InSanaa +)38
WEB' www.Duib�r8d�or:.o!n
W
J
W
M ry
O o
O
a j N �
0
er
cQc
G
W
Cl.
LL a
5<-
pa
�
m<aLL
C)
5
�v
m
l7
H
W�
W
o
W
z)
o
k-�z
O
F
U
REMARKS
I BYJ DA
fdd ADA sill, MP Luck, Radius Lt.
GL 6/2.
Add GU
Hardware
I LS 8/2
D3«AU Nar Bf frxcoucEo rN —11 Da —v
CONSENT Dn BNnD.NG Dons, INC
A� krN ATIDNS. ADWlIONS, rliGinIGNTING. CR C1rrfB
ranBaiNr, vusDnTE ala unn:rcmrxExMrTnonuD
\\1111111111
DATE: 02.05.14
DWG. Y: CHK. Y:
GL TJM SS MSS
SCALE: NTS
DWG. u: A010872A
10
BUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization: 29578
Product Evaluation Report
Of
398 East Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@ buildingdrops.com
JELD-WEN, inc.
Design Pro / Smooth Pro Fiberglass
Impact Approved Glazed Doors ....
40
For use in the High Velocity Hurricane Zone (HV.yo
...... .....
..
for ......
•
. ....:00 00......
Florida Product Approval ••;••; •••• .
..:...
.. .. ..
......
Report No. 4438.1 ' :
......
..
Current Florida Building Code :.".
.
•
...
Method: 1— D (Engineering Evaluation)
Category: Exterior Doors
Sub — Category: Swinging Exterior Door Assemblies
Product: Design Pro/Smooth Pro Fiberglass
Impact Approved Glazed Doors
For use in the High Velocity Hurricane Zone
Material: Fiberglass
Product Dimensions: 3'-0" X 6'-8" (Nominal)
3'-0" X 8'0' (Nominal)
Prepared for:
.IELD-WEN, inc,
3737 Lakeport Bled,
Klamath Falls, OR. 97601
Prepared by:
Hermes F. Norero, P.E.
Florida Professional Engineer # 73778
Date:11/15/2017
Contents:
Evaluation Report Pages 1-4
Digitally signed by Hermes F. Norero, P.E.
Reason: I am approving this document
Date: 2017.11.17 10:27:09-05'00'
F. O
�O
7 '
Hermes'd!Mdl��o, P.E.
Florida No. 73778
BUILDING DROPS
Date: 11/15/2017
A Perfect Solution in Every Drop! Report No: 4438.1
Certificate of Authorization: 29578
Manufacturer: JELD-WEN, inc.
Product Category: Exterior Doors
Product Sub -Category: Swinging Door Assemblies
Compliance Method: State Product Approval (1)(d)
Product Name: Design Pro / Smooth Pro Fiberglass •
Impact Approved Glazed Doors •
.... ......
For use in the High Velocity Hurricane Zone (HVHZ) • •
3'-0" X 6'-8" (Nominal) "•'•• •• •• •.....
3'-0" X 8'-0" (Nominal) ...... •
.... ......
.... . .. .....
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL*7:;;18) for JEL60iNEN 1Rt0
based on Method id of the Florida Department of Business and Profess;dPlZraegulatiort - Florida • •
Building Commission. ,•00:• ••••••
. . . Oo
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the comp2giy. •
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
Limits of Use:
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions A010872, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for
specific use parameters.
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the current Florida Building Code and does not require an impact resistant
covering.
4. Site conditions that deviate from the details of drawing A010872 require further engineering
analysis by a licensed engineer or registered architect.
5. See Installation Instructions A010872 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No. 73778
Page 2 of 4
BUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization: 29578
Date: 11/15/2017
Report No: 4438.1
Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a Certification Agency through
National Accreditation & Management Institute (FBC Organization #QUA1789).
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
Referenced Data: •„•
�•��•"�:'
1. Product Testing performed by National Certified•Tesking
La59gJ nes
(FBC Organization # TST1589) . •. • • •
Report# ReportAtle`.
;•, •, ••����
NCTL-210-3924-01 12/18/;1* * �
� "• � � � �
�
NCTL-210-3925-03 02/07/�•„•
ji
� • � ,
•00
NCTL-210-3916-02 w/ addendum 06/10/,1 ....
0 •
NCTL-210-3930-01 02/24A4
•
.... %
NCTL-210-3930-02 03/10A4 .'.
TAS Report Engineer of Record: Gerard J. Ferrara,'P.E*
• •
: •
.".
Report # Report Date:
SJW2013-194-TAS w/ addendum 06/10/14
SJ W 2013-208-TAS 11/13/13
TAS Report Engineer of Record: Kevin P. Tyra, P.E.
Report # Report Date:
SJW2013-230 11/26/13
SJ W 2013-231 12/03/13
SJ W 2013-251 12/23/13
SJW2013-252 12/23/13
SJW2013-253 12/23/13
SJ W 2014-032 04/22/ 14
SJ W 2014-073 06/26/14
SJ W 2014-077 06/27/14
SJ W 2014-072 06/27/14
SJW 2014-080 07/03/14
TAS Report Engineer of Record: Robert H. Zeiders, P.E.
Report # Report Date:
SJW2016-006 02/22/16
TAS Report Engineer of Record: Harold E. Rupp, P.E.
Hermes F. Norero, P.E.
Florida No. 73778
Page 3 of 4
//Q,\\ BUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization: 29578
Installation:
2. Quality Assurance Entity
National Accreditation & Management Institute
(FBC Organization #QUA1789)
Date: 11/15/2017
Report No: 4438.1
Component Material Testing of Dylite Expandable Polystyrene by
Intertek Testing Services NA, Inc.
ASTM E84
Report#: 3113726SAT-001 R1 Report Date: 03/13/09
4. Component Material Testing of Fiberglass SMC,jki r�•• •....' ..••••
Element Materials Technology " ' • • • ; •
ASTM D635 ASTM D638 ASTM D1929 ASTM D•2Y&, •ASTM G 15S' ......
Report#: ESP010982P Report Date: 02/26/13 ••••5. •• �• �....:
.... . .. .....
Material Certifications .••••
Miami -Dade County RER — Product Control SeCtfofl40A •• ••....
Current NOA for Solutia PVB Interlayer (Saflex 5' E3?trnan Chei%cal Co.) %
Current NOA for SGP Interlayer by DuPont (SegryGl�s by Kprarey►Americaj'**
. .
Approved anchor types and substrates are as follows:
Through Frame Installation:
A. For two by (2X) wood buck substrate (Min. S.G. = 0.55), use #10 Wood Screw type
installation anchors of sufficient length to achieve a minimum embedment of 1.50" into
the wood substrate.
B. For concrete (Min. f'c = 3000 psi) or masonry (Conforms to ASTM C90) substrate where
one by (1X), non-structural, wood bucking is employed, use 3/16" diameter ITW Tapcon
or %" Elco Ultracon type concrete screw anchors of sufficient length to achieve minimum
embedment of 1.25" into concrete or masonry.
C. For concrete (Min. f'c = 3000 psi) or masonry (Conforms to ASTM C90) substrate where
wood bucking is NOT employed, use 3/16" diameter ITW Tapcon or %" Elco Ultracon
type concrete screw anchors of sufficient length to achieve minimum embedment of
1.25" into concrete or masonry.
Refer to Installation Instructions (A010872) for anchor spacing and more details of the installation
requirements.
Design Pressure:
Refer to Installation Instructions (A010872) for design pressures based on size & configuration of
door units.
Hermes F. Norero, P.E.
Florida No. 73778
Page 4 of 4