Loading...
RF-19-654Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 04/08/2019 Location Address Parcel Number 10520 NE 6TH AVE, Miami Shores, FL 33138 1122310140310 Contacts Permit No.: RF-03-19-M Permit Type: Roof Work Classification: Tine Permit Status: Approved Expiration: 10/07/2019 Alejandro Menendez Owner HEROES ROOFING CORP Contractor 10520 NE 6 AVE FAURE COLLAZO HIDALGO 4968 SW 136 PL, MIAMI, FL 33175 Business: 7865167179 FAURECOLLAZO@GMAIL.COM Mobile: 7865167179 Inspection Requests: Description: RE -ROOF WITH SAXONY 900 SLATE WHITE TILE Valuation: $ 21,500.00 Inspe tion Re FROM BORAL 49 Total Scl Feet: 2,690.00 Fees Amount Application Fee - Other $50.00 CCF $13.20 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $4.40 Roofing Fee $250.00 Scanning Fee $12.00 Technology Fee $7.50 Total: $344.60 Payments Date Paid Amt Paid Total Fees $344.60 Credit Card 03/27/2019 $50.00 Credit Card 04/08/2019 $294.60 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are requir for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. 1 OWNERS AF ID T: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating co tru i n and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized St/646re: Owner / Applicant / Contractor / Agent Date April 08, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ROOFING RECEIVED AR 2 7 2019 BY• FBC 20 1--+ Master Permit No.0' 03V 19 -ps� Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: t o5zo Ave. rity• Miami Chnrac County- Miami Dade Zin: i'1. 33i38 Folio/Parcel#: li- Z 231 -01-1- 0310 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): tjIQ(AV J fU M. f" lBYIQi UP-Z . Phone#:V�W .3r'f - V.7M.7 Address: io5$zb mE, o 4Ve, City: 44(m' Skore& State: Zip: 31138 Tenant/Lessee Name: Phone#: Email: q.%u McAmde z _ AM& OOrA CONTRACTOR: Company Name: ' 1eYcleswlvl(; Gvt Phone#: t% Address``: '�gq(,8 Sw luo Al City: M1()l1Nll State: Zip: Qualifier Name: ;Ltjrt, (11koLZ0 Phone#:(17%) 6%,-'?(79 State Certification or Registration #: CC.C. 1331k (o-4 Certificate of Competency #: DESIGNER: Architect/Engineer: Address: Value of Work for this Permit: $ V 1900 Type of Work: ❑ Addition ❑ Alteration Description of Work: !'fie_ Specify color of color thru tile: Submittal Fee $;�' (5(::) Permit Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ Radon Fee $ City: State: Zip(: Square/Linea;�Re!pi t of Work: 2('0 C✓'1 El New r/Replace ❑ Demolition Training/Education Fee $ CCF DBPR $ CO/CC $ Notary $ Double Fee $ Bond $ 15 I�G TOTAL FEE NOW DUE $ 2 LA `s (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and ection fee will be charged. Signatur 47-Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this 2 Z, day of 1412 rC% , 20 11 % by AIQ1(iydr0 i4J1JfHdL*Z who is personally known to Iri me or who has produced identification and who did 4anth. NOTARY PUBLIC: Sign: Print: w Seal: : �•• Notary Public - State of Florida �= Commission # GG 29812 My Comm. Exp. Nov. 30, 2020 The foregoing instrument was acknowledged before me this Z 2— day off, M Q MC�'�I , 20 rF / by �iQ (aynYIQ'Z-O who is personally known to as = or who has produced as identification and w did take an oath. NOTARY PUBLIC: 0 Sign: _ Print- "J' `1l .`t;` Notary Public - State of Florida Seal: Commission # GG 29812 My Comm. Exp, Nov. 30, 2020 *******s****rr:*ss*■*s*s**4*71?tf APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 3/27/2019 Propertv Search Application - Miami -Dade County 0 OWN= riii,ii,iICE OF THE'PR0rP%ERN1r`y# APIIRAIS'ER Summary Report Property Information Folio: 11-2231-014-0310 Property Address: 10520 NE 6 AVE Miami Shores, FL 33138-2050 Owner ALEJANDRO MANUEL MENENDEZ SYLVIA ALEXANDRA ZAKZUK Mailing Address 10520 NE 6 AVE MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3 / 3 /0 Floors 1 Living Units 1 Actual Area 2,206 Sq.Ft Living Area 1,773 Sq.Ft Adjusted Area 1,985 Sq.Ft Lot Size 9,412.3 Sq.Ft Year Built 1945 Assessment Information Year 2018 2017 2016 Land Value $190,473 $211,637 $177,502 Building Value $161,643 $144,028 $145,064 XF Value $0 $0 $0 Market Value $352,116 $355,665 $322,566 Assessed Value $352,116 $322,339 $293,036 Benefits Information Benefit Type 2018 2017 2016 Non -Homestead Cap Assessment Reduction $33,326 $29,530 Homestead Exemption $25,000 Second Homestead Exemption $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description AMD PL MIAMI SHORES SEC 5 PB 10-47 E1/2 LOT 23 & LOT 24 BLK 110 LOT SIZE 77.150 X 122 OR 20490-1279 04 2002 1 Generated On : 3/27/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $0 $0 Taxable Value 1 $302,116 $322,339 $293,036 School Board Exemption Value 1 $25,000 $0 $0 Taxable Value 1 $327,116 $355,665 $322,566 City Exemption Value 1 $50,000 $0 $0 Taxable Value $302,116 $322,339 $293,036 Regional Exemption Value 1 $50,000 $0 $0 Taxable Value 1 $302,116 $322,339 $293,036 Sales Information OR Previous Price Book- Qualification Description Sale 107/22/2017 Page $450,000 30649- Qual by exam of deed 4789 25890 Sales which are disqualified as a result of 08/01/2007 $0 4274 examination of the deed 03/01/2004 $280,000 22187 Sales which are qualified 2176 04/01/2002 $220,000 20490- Sales which are qualified 1279 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version Section A/B MIAMFDADE y' Miami -Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section A (General Information) Master Permit No: Process No: Contractor's Name: Heroes Roofing Corp Job Address: 110520 NE 6 AVE, MIAMI SHORES, FL 33138 I�) Roof Category ❑ Low Slope ❑ Mechanically Fastened Tile Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other: Roof Type .'•'•. . . .... ...... ❑ New Roof ❑ Re -Roofing ❑ Recovering ❑ Repair ❑ MaintenanM • ...... .. .. ...... Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No If yes, what type? • � f atural 0 LPGX • • ...... Roof System Information . • • • • . : • . • . • .... . .. ..... Low slope roof area (ft.z) 10 Steep Sloped area (ftz) 96 Total (ft.z) __ • Section B (Roof Plan) • • • • • • • Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and -overflow draws' lAdlude . dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and locNan J parapets. - • : • • • • •••• Perimeter Width (a'): .3.rf Corner Size (a' x a'): 3 (p9 w Q \ Uw ¢ O w w QLJ42� \, ~ o C� w w O i Q � z z O O I ~ a �I o w o `' I N' ? — �,CEIVED 99 1 Tile Roof System MIAMI DADS ss Miami-0ade County HVHZ Electronic Roof Permit Form Section D Tile Roof System "Delivering Excellence Every Day" Roof System Manufacturer: Boral Roofing, LLC Notice of Acceptance Number (NOA): 18-0509.17 Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P 1 • �R i P 2• rp8._I _ P 3• IO0.7 Maximum Design Wind Pressures, (From the NOA Specific system): 31.3 psf Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof Slope: "/12" Roof Mean Height: 2 ft. Method of Tile Attachment: Adhesive, 2 Small Paddy Polyfoam Polypro-Iji Alternate Method of Tile Attachment per NOA: (N/A) Drip Edge Size &Gauge: 3" face 26 ga.-- Drip Edge Material Type: Galvinlzed Metal-- Drip Edge Fastener Type: 1-1/4" Ring Shank Nail @4" o.co.c� Hook Strip/Cleat gauge or weight: Deck Type: -1" x 6" T & G— Optional Insulation: (N/A) ...... • .. .. Optional Nailable Substrata.* (N/A) ...... ... Optional Nailable SubstrateAttechment. (NIA) Basesheet Type: STM Felt #30 D-226 Type 11 Fastener Type for Basesheet Attachment: 1-1/4" Ring Shank Nail w/ 1-5/8" Tin Caps' Tile Underlayment (Cap Sheet) Type: arco PS 200HT Tile Underlayment Attachment Method: Self Adhere _ - Tile Profile: Saxony 900 Slate V099: •0:00 •0000 ...... •000*0 Section E L �` "i MIAMNDiADE "Delivering Excellence Every Day" Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tie systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the the attachment method is acceptable. P 1: 9.1 X 0.315 = 12.31 _ Mg: 62 = Mr1: 4.69 < 31.3 NOA Mf P 2: 68.1 X X0.315 = 1.45 _ Mg: 62 = Mr2: 13.83 < 1.3 NOA Mf P 3: 100.7 X I0.315 = 1.72 _ Mg: _62 = Mr3: 24.1 < 1.3 NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127" . .... ...... For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are great tDAn Qr equal io the f r values, for* each area of the roof, then the file attachment method is acceptable. • • •.••.. .• •. ..•.•. • •••••• MM M mm x cos 9: F7 = Fr1: _�... • r . _ T`I(; F' xCos 9:�=F2: ••• �NCiAF xCos ():r7=Fr3:F'-w'7r JMF' • • . • • • • • • Where to Obtain Information to complete the calculations • • • • Description Symbol Where to Find Design Pressure P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope 9 Job Site Aerodynamic Multiplier Product Approval (NOA) Restoring Moment due to Gravity Mg Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NOA) Tile Dimensions I = length w = width Product Approval (NOA) SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. 4MO ` Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually.. concealed prior to removing the existing roof system). ...... ...... .. .. ...... 4. Ceiling: Exposed, open beam ceilings are where the urrdtM(Vof the rooPdecking ;....; can a viewed from below. The owner may wish to maintain the architectural apAdMoce; thde sorb, ' roofing nail penetration of the underside of the decking may not be acceptable. Phis Qrovideslhe option of maintaining the appearance. . : .. .. .. ...... . . . . ...... 6. a Overflow scuppers (wall outlets): It is required that rainwater flows off so that re oroot'is not overloaded from a buildup of water. Perimetededge wall or other roof exterision mey block this - discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install ove;%1 scuppers in accordance with the requirements of Sections R474 and R4413. ZZ 20Zo/9 . aOne—r/Aqe—nt's?Sig nature Date Contras or Signature Date JOS 2b AIE fo AWE Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number Heroes Roofing Corp. 4968 Sw 136th Pl, Miami, FL 33175 EROES Cell (786) 516-7179Mail. faurecollazo@gmail.com R O O F I N G March 23, 2019 Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FL 33138 Truss to Wall Hurricane Mitigation Standards Letter RE: 10520 NE 6th Ave, Miami Shores, FL 33138 To whom it may concern: • • • ...... .... State Law mandates that you are not obligated to install new straps (tie the trusses) wVeh't1lis type of' work will incur in an additional cost of more than the 15% of the face value of the contract,•In thic casd . the cost of bringing the straps up to code is $4,100. The total cost of the contract is $;1,�5.. thus Atha additional work will cost 19% more. We would like to ask for an exemption on this addlt phal work siuce the cost will exceed the 15% margin. • • • • • • • Regards, 4�� Faure Collazo Company Co-owner & Qualifier Lic. #: CCC1331164 STATE OF FLORIDA COUNTYOF MIAMI DADE Sworn to ands bscrib d before me this �3 Day of ov- 2019 (Seal) f Personally Known DAMARYS HIQALGO �• ; Notary Public - ate of Florida Y F Commission # GG 29812 or Produced Identification My Comm. Exp. Nov. 30, 2020 .. . . .. .. MIAMDARE � MIAMI-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have ibis. product or material tested for quality assurance purposes. If this product or material fails to ; to the �ccc ted 0 0 p q tY PAP P P I�7Z � P. .' manner, the manufacturer will incur the expense of such testing and the AHJ may immediatel}zrw*e, md4iJJ„4r , 0, 0; suspend the use of such product or material within their jurisdiction. RER reserves the right to covoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or materal41-failg to mte 0the0 : 0 0 0 0 requirements of the applicable building code. .... . .. ..... This product is approved as described herein, and has been designed to comply with the FlorMMa B6llding Cd'de : ""' including the High Velocity Hurricane Zone of the Florida Building Code. 000 0 0 0 0 ...... DESCRIPTION: Saxony 900 Concrete Roof Tile •• • • •• LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state andiflbwing statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any sectioi of this NOA shall be cause for termination and removal of NOA. . 0000 . •0000: ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-0711.05 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 18-0509.17 MIAMMADE COUNTY Expiration Date: 04/26/22 ' Approval Date: 08/02/18 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Saxony 900-Slate Saxony 900 Split Shake Saxony 900-Shake Trim Pieces Length = 17" Width = 13" thickness = 1-5/32" Length = 17" Width = 13" thickness = 1-9/32" Length = 17" Width = 13" thickness = 1-9/32" Length: varies Width: varies varying thickness Test Product Specifications Description .... TAS 112 . ... .. Flat profile, interlocking, hk prossure. a xtruded ..... • concrete roof tile with two Vg4 &jes. Fej dire; t deck,. • • : • batten, mortar set or adhesive sjtapplications. • TAS 112 Flat profile, interlocking, high'-pfessure Oft uded • tile two nailholes. For direct decR,':". concrete roof with ...... ... . ..... batten, mortar set or adhesin 91 applicahoa 0 0Top • • surface produced with 4 digFrW4,configuratons: • • 1. Complete tile brusbed' : 0 0....:. 2. Right half brushed ishown in drawing f 3. Left half brushed • • • • • 4. No brush TAS 112 Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. TAS-112 Accessory trim, boosted Barcelona, concrete roof pieces for use at hips, ridges and rakes. NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 2 of 9 2.1 MANUFACTURING LOCATION 2.1.1 Lake Wales, FL 2.2 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 94-060A Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 25-7183-6 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik-Drive Screws, Direct Deck) The Center for Applied 25-7183-5 Static Uplift Testing TAS 102 Feb. 1995 Engineering, Inc. (2 Quik-Drive Screws, Battens) The Center for Applied 25-7214-1 Static Uplift Testing TAS 102 March, 1995 Engineering, Inc. (1 Quik-Drive Screw, Direct Deck) The Center for Applied 25-7214-5 Static Uplift Testing TAS 102 M4rti1' 1295 Engineering, Inc. . (I Quik-Drive Screw, Battens;... .... ... ... . The Center for Applied Project No. 307025 Wind Driven Rain 0 9 • • O �t0 �9�4 • Engineering, Inc. Test #MDC-77 TAS 100 , , , ; , , , Redland Technologies 7161-03 Wind Tunnel Testing •::::• IPec.1991 Appendix II & III TAS 108 (Nail -On) ...... 000 & • goes* Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing „',.' Aug. I.V4 �, • TAS 108 (Nail -On) . , .... .' Redland Technologies P0631-01 Wind Tunnel Testing = July TAS 108 (Mortar Set) • Redland Technologies P0402 Withdrawal Resistance Testing of 0 S;pt•14993 0• screw vs. smooth shank nails ' •' Atlanta Testing & R1.894/R2.894/R3.894 Physical Properties Aug. 1994 Engineering, Inc. TAS 112 Cclotex Corporation 520109-1 Static Uplift Testing Dec_ 1999 Testing Service 520111-4 TAS 101 Celotex Corporation 520191-1 Static Uplift Testing March 1999 Testing Service TAS 101 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584/25-7804b-8/25-7804-4 & 5 December 1996 25-7848-6 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moments Due to Gravity 09/01/16 American Test Lab of RT0617.04-16 TAS 112 06/29/16 South Florida NOA No.: 18-0509.17 M1AM1•DADE COUNTY Expiration Date: 04/26/22 �FlugernvApproval Date: 08/02/18 Page 3 of 9 PRI Construction Material COPO-002-02-12 TAS 101 10/12/2016 COPO-002-02-06 TAS 101 10/12/2016 COPO-002-02-05 TAS 101 10/12/2016 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. • • • • 4. INSTALLATION • •,;. • • 4.1 Saxon 900 Slate Shake & Split Shake Concrete Roof Tile and its componentcomponentj Shall a insj e& n strict • • • •. compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 12Cr • •' • • • • • • • 4.2 Data For Attachment Calculations • Table 1: Average Weight (W) and Dimensions (i x w) ••..;• Tile Profile Weight-W (lbf) Length-1 (ft) . •. Wift-w (ft) ;.. •„ Saxony 900 Slate, Shake & Split Shake 10.9 1.417 '� • • Table 2: Aerodynamic Multipliers - .% (ft3) Tile X (ft3) X (ft3) Profile Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile greater Saxony 900 Direct Deck Direct Deck Battens Direct Battens Direct Battens Direct Battens Direct Slate, Shake & Deck Deck Deck Deck Split Shake 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 NOA No.: 18-0509.17 MIAMI•DADE COUNTY Expiration Date: 04/26/22 � ' � � N ' Approval Date: 08/02/18 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32", plywood) Battens Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2 Slate, Shake & Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Shake 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 X8 Screw 30.8 30.8 18.2 218 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 •••• Table 5: Attachment Resistance Expressed as a Moment Mf ( •Ib) • • � for Two Paddy Adhesive Set Systems • • •; • • • • • • Tile Tile Application M1Qwwm AttAchgnent Profile ' • •.Resistan�o.' Saxony 900 Slate, Shake & Split Shake Adhesive' 1.3 2 • • 594 • •.••.• 04 . . 00 1 See foam adhesive manufacturer's component a roval for installation re uirements. . • 2 The Dow Chemical Company TileBond' one -component foam minimum weight per paddy 13.9 grams. "' 3. ICP Adhesives Polyset@ AH-160 two -component foam, minimum weight per paddy 8 grams. 4. DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 8 rams. . Go% Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake ICP Adhesives Polyset® AH-160 Two -component foam DAP Products Touch N' Seal Storm Bond 2 two -component foam 118.9 3 40.4 4 93 5 45 6 3 Large paddy placement of 45 grams of Polyset® AH-160. 4 Medium paddy placement of 24 grams of Polyset® AH-160. 5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 45 grams. 6 Medium paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 24 grams. NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 5 of 9 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-ibf) for Mortar Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake Mortar Seth 43.96 7 Tile-Tite Roof Tile Mortar 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". ...... •• •• LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES F U PLANT ...... ... . LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS • • • • 6.1 Application for building permit shall be accompanied by copies of the following. .. • • • • e 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 6 of 9 NAIL HOLES G UNDERLOCK I SAXONY 900 - SLATE 5/32" (Slate) COVERLOCK ..• t NOA No.: 18-0509.17 cMIAMI•DADE COUNTY Expiration Date: 04/26/22 ._ Approval Date: 08/02/18 Page 7 of 9 PROFILE DRAWINGS NAIL HOLES Note: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush SAXONY 900 - SPLIT SHAKE 1-9/32" (Shake) 13; NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 8 of 9 NAIL HOLES 1i PROFILE DRAWINGS SAXONY 900- SHAKE END OF THIS ACCEPTANCE 1-9/32" (Shake) • • • j • • • • • • • • • • • NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 9 of 9 MIAMI-DADE COUNTY MI�MHMM PRODUCT CONTROL SECTION jm i) 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 441e Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptjac,j�, if it is determined by Miami -Dade County Product Control Section that this product or material fails to tpeet the re4wiement&.... of the applicable building code. 1.6 • This product is approved as described herein, and has been designed to comply with tht*trolida Building Code '" including the High Velocity Hurricane Zone of the Florida Building Code. • ""' .... . .. ..... DESCRIPTION: ICP Adhesives Polyset' AH-160 """ • .. .. .. ...... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo ctby,:state ind fgllowing . � • ; � statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. . 0 ; RENEWAL of this NOA shall be considered after a renewal application has been filed and there has be6onoo change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives N/A TAS 101 Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 Product Description Two component polyurethane foam adhesive Dispensing Equipment • . . •..• •...•• .. • Dispensing Equipment • • " " • • 0 0 • .... . .. ..... ...... ... . ..... PRODUCTS MANUFACTURED BY OTHERS: . • • • • • 0 • • • • ; • Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current N(WiMch list atta chment • • •,; resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. 0 ; • • • • • MANUFACTURING LOCATION: l . Tomball, TX. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 . •• • • •• • . . Results 1.6 lbs./ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ftz 3.1 Perm / Inch +0.07% Volume Change @ -400 F., 2 weeks +6.0% Volume Change @1581F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Mu1MMADE COUNTY Expiration Date: 05/10/22 *' ' Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94-060 257818-1 PA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[1] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 ASTM D 1623 ASTM E 108 ASTM E 108 ASTM E 84 TAS 114 ASTM D 1623 TAS 101 • ..' TAS 123 ...... TAS 101 •••• TAS 101 TAS 101 Date 04/08/94 12/16/96 10/25/95 11/02/95 12/12/95 02/01/94 04/30/93 11/16/94 01/16/95 03/1 jV�6 04• 1$I.AZ 02/21/12 10r2�/98� 12/28F 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 1CP Adhesives Polysee AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 1CP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 ML MFDADE CODU Expiration Date: 05/10/22 �U,1221611401 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 orJCY •. Adhesives ProPack® 30 & 100 dispensing equipment only. • • . • • • • • • 7. ICP Adhesives Polyset' AH-160 shall not be exposed permanently to sunlight. ...... • .. • • 000000 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutet`aftef1CP Adhesives • • • • .... .. Polyset® AH-160 has been dispensed. - Soso S .. ..... 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in acco:daiwo�with the• • e • • • • • • 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.00 • • • • ;' ...... • ...... ...... .. . . .. . ..0000 NOA No.: 17-0322.03 MIAMFDADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two �P'ece an iBarrel (P Tle Two i) T Piece - sq. inches 65 70 h 3.4 graing mWe? pan • • • • • • LABELING: • • • , • • • All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking' of tha • • • • • • • • • manufacturer's name or logo and following statement: "Miami -Dade County Product Control Apppwrd" orth%Ntami- • •' •' • Dade County Product Control Seal as shown below. • • •' • : • C OADE COUNTY i • i • • • • • • • • •..M 2I ••s••• BUILDING PERMIT REQUIREMENTS: goes As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Muu7MADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 MR through plank ceem t paddy MartaathTie) I required) 11^ 11 r- 101 t►rsd.riym•nt {, . ,f U"Cou" i Nall through plastic cement (when required) _.Paddy le"viathTool 21n.wtbe r� 'y. l tattertsopelonal `'• �- _ ,, r f,r� l ,y Emclosure Em Course f `` � ' �— Fascia KA through pleatae r . p eldlr 1R.�..sl.Til.h (when requer•ah una.rf.yn nt r1 Iin, whde Z `. Battens optional E&wCourse--.-i ✓ x/' Fasda W'eePh+oic r01n ] in. '`r E•+e closure % orlpedge APPROVED Flat/Low Profile Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile ••i• 1. Starting at the cave course, apply a mithjrlWp2 2" • e e e e (50.8 mm) x 10" (254 mrnl rl';(25.4 rjam) fpam •', paddy onto the underlaynaQu4pwitionSd as stown ...... under the pan portion of theetteclosest to the • overlock of the tile beingek • • • ; • • • • • •.•• . •• ••:••• 2. Continue in same manner' TQM appr8 thaftely 17" • • (109.7 cm) — 23 (148.4 M) •stluare inch aal►esive • . • • : • • contact with the underside MAdo tile. • • • • • •••••• •• • e •• • • •••• High Profile / Single Pan Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL ## 2 k2a d r m!;h plastic tomint Paddy 1& m"thTW.l (wham required) e � f Bartemoptlonal Fasda Eave closwo •__�r�9' Nail through plastic cement {when requiredl r ----Paddy jeentath tilt) und.rlaymone in. - Batterrsoptional { loin" E"o Closure Eavv Course Fares MIAMNDADE COUNTY F-AMMIUR11� Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesi4e. contact with the underside of thg tile. • • • • """ . • ....... .. .. ...... Medium Profile / Double Pan 'T$e• • • • • • • • 1. Starting at the eave course, VPlyiteminii4io 2 .(50.8..:..' mm) x 10" (254 mm) x 1" (2.%4 jv&) foam paddy ...... onto the underlayment positimedew shown under the • of the tile closest to Atc;overlock o f the see** pan portion .... tile being set. Insure approximately�17 (1®9.7 cm2) — ;....; 23 (148.4 cm2) square inch adhesive cont$ct.ftb the ' underside of the tile. 0000 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the file being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nab through Ptaslx to pd Tii.} tvA�en pequlred) al18•n.wh Battens oodor., r EaveCourse "b. fascia 1�in. 2 in. Ern dowse Drip edge MIAMMADE COUNTY High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm) -19 (122.6 cm) square inch adhesive contact with the underside of they tile. - . .... ...... a . ...... .. .. ...... .... . .. ..... ...... ... . ..... .. .. .. ...... . . . . ...... • • • . .. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Flail through plastic cement Paddy lbetween ties) (when required) Battens optional ° " Paddy lender tile) Single paddy f ontopottle �= i 4xa)n i' le pad ��• single paddy un on uredertaym •E` 2 x a in. Fascia Ore Closure Flat/Low ProflleTile Nan through plastic cement Single paddy under tie (when required) Paddy (between dies) Barons Paddy (under tile) optional r o pad top of 4x4in. •' ' Sinolepaddyan xain.` uunnd&erdlaapnent _ loin. �'•�` z)n. Eave Closure Eave Course Fascia Medium proflieTlie MIAMFDADE COUNTY • r 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat rile or under the pan portion of the tile for low or high profile tile closest to the overlock of the rile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cm) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed..IMVe. approximately 8-9 in2 (A.64%1 cm2) oradhesive • •: • contact with the underside of the tile.• • • : • • •••••• •• •• •••••• • (Instructions continued on 044We) ..... •••••• ••• • ••••• .. .. .. ...... • • • • •••••• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) HaAthrough Plastic Single paddy under tile (when requbed) Paddylbetween tiles) Battens optional ,,-� Paddy(undertile) SingleU00tm opaddy n S' axsin. �'� ti Single 2sai paddy on tap of tile Eave course `-= Fasda Weephole loin. 2 in. Eave dosure Dripedge High ProillaTlle 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4' (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 f ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq.in. Steep pitch applications in contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive dinto 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25sq.in.contactarea, Underlayment Eave closure (motar shown) Fascia Remove top portion of the save course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cmZ) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhdsive directly aialhq inner edge of each side of tit cgvt tile. U31d """ approximately 3/4" (19Mm)'to 1" V5.4 nim) '. from the outside edge UTIV file, inwaid free of* • • • • ..toes s s foam to allow for expans .iorll. • • :sees: .... . .. ..... 4. Turn cover tile over a4er fqw is applied and place onto pan tile couxse.dia'sure a minimum of o e 9 o .. 20 (129 cmZ) - 25 (161a3 c.mj square inch • • contact area on each side of the cove 141 Jo the • • • • • pan tile. Continue in s$meA4nner. `Prim away • any cured exposed foalrt Adhdsive. l:oiiih$g of ' longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 MIAMaAADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy Tarco Specialty Products, Inc. One Information Way, Suite 225 Little Rock, AR 72202 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,Xi". is determined by Miami -Dade County Product Control Section that this product or maler al fails to • meet the requirements of the applicable building code. ' ...... .. .. This product is approved as described herein, and has been designed to comply witlfdl r•FPbrida Buirding Code including the High Velocity Hurricane Zone of the Florida Building Code. : 0. 0 • DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name MUE4, city, stale and following statement: "Miami -Dade County Product Control Approved", unless gtheryvise now • • • herein. 9 .. 0 : .110. RENEWAL of this NOA shall be considered after a renewal application has been filed and there'lia' been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 11-0912.04 and consists of pages 1 through 16. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 1 of 16 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: Asphalt, SBS, Polyester SCOPE: This acceptance is for Tarco Roofing Membrane and Underlayments, for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved adhesives, fasteners and fastener densities, as described in this Notice of Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. PRODUCTS DESCRIPTION: Product Dimensions Test Specification Product Description 30# ASTM 3' x 72" rolls ASTM D226 Type H Asphalt saturated felt underlayment Specification Felt Manufacturing Location #1 & #2 EasyLay 3' x 133' 4" ASTM D226 Type II Sheet material comprising a pole &O, Manufacturing rolls substrate coated witti bituminous Mating � • �': • Location #2 for use as an underlW* n.en in roe ipg • ...... . .. applications. Desigpgd W a shingle metal roofing underla}unant and For uce :' •": in tile roofing assern6ims when used* • • • • • • • with an approved TAS;10I tile "•. '•"' underlayment cap slte'et! • • • •: Fiberglass Mineral 3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinfgWA • • • • • • Surfaced Roll asphalt coated roll raofiut for hol mo :....: Roofing or cold process application. Manufacturing Location #1 ASTM Organic 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt Tile Underlayment Type II underlayment for hot mop application. Manufacturing Location #1 EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced, Manufacturing SBS modified bituminous membrane for Location #1 hot mop or cold process application. Designed as a tile roofing underlayment. NOA No.: 12-0420.02 MIAMI•DADE COUNTY Expiration Date: 01/25/17 • a • " Approval Date: 10/03/13 Page 2 of 16 Product Dimensions Test Specification Product Description Fast90 3' x 36' rolls TAS 103 Granular surfaced, asphalt -impregnated Manufacturing ASTM D249 organic felt reinforced, bituminous sheet Location #1 ASTM D6380 material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a tile roofing underlayment. PS200HT 3' x 66'8" rolls TAS 103 Fabric surfaced, fiberglass reinforced, Manufacturing ASTM D1970 SBS modified bituminous sheet material Location #1 & #2 with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a shingle, the and metal roofing underlayment. PS200mu 3' x 66'8" rolls ASTM D1970 Film surfaced, fiberglass reinforced, Manufacturing SBS modified bituminous sheet material Location #1 & #2 with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. MS300 3' x 66'8" rolls ASTM D 1970 Fine granular surfaced, fiberglass • • • • Manufacturing 3' x 33'4" rolls reinforced, bituminoug sheet material : Location #1 & #2 with a self-adhesive Boom layerO Nr • use as an underlaym 0r t0 sloped loo f assemblies. DesignEoXA ice Ind.. • water shield, and a shingle roofing• • underlayment. • • • • • • SS400 3' x 66'8" rolls ASTM D1970 Smooth surfaced, flOergla$s reinforced Manufacturing 3' x 33'4" rolls bituminous sheet materiai with arself- Location #1 & #2 adhesive bottom layer for use a$an • • . underlayment in sloped roof assem6res. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NR500HT 3' x 66'8" rolls ASTM D1970 Film surfaced, non -reinforced, Manufacturing bituminous sheet material with a self - Location #3 adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NOA No.: 12-0420.02 Expiration Date: O1/25/17 Approval Date: 10/03/13 Page 3 of 16 MANUFACTURING LOCATIONS: 1. Greencastle, PA 2. Belton, TX 3. Coshocton, OH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Atlantic & Carribean Roof ACRC06-013 TAS 103 06/14/06 Consulting, LLC PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type lI 08/22/02 TOT-029-02-01 TAS 110, ASTM D249 & D 6380 07/05/05 TOT-030-02-01 TAS 110, ASTM D249 & D 6380 07/05/05 TOT-041-02-01 TAS 110, ASTM D226 Type II 05/24/06 TOT-042-02-01 ASTM D4798 & ASTM G155 05/22/07 Trinity I ERD T3580.10.06-2 TAS 103 10/26/06 T3580.10.06 TAS 103, ASTM D6380 10/12/06 T30160.08.09-R1 ASTM D1970 10/12/10 T10550.07.08 ASTM D4798 & ASTM D1970 07/30/08 T32530.08.10 ASTM D1970 08/17/10 T33190.08.10 TAS 103 081d6/Ib• T43930.09.13-R2 TAS 104 • • • ; 091013 • • • • T40790.04.12 ASTM D6380 0 • • * •. 04/'QNt2: ....:. T40780.04.12 ASTMD3909 ...%. 04/06/42 • T37610.07.11 TAS 114-D • • • • 07/f9i 1 I • • .... . .. ..... IRT-Arcon IRT07-0006 ASTM D1970 ...... 07/II107 • • • • • IRT 07-0036 ASTM D 1970 • • • • • 02/22/08 - • • • • ; • IRT08-0002 ASTM D1970 ; • • ; • ; 02/22/08 . . . . ...... GENERAL LIMITATIONS — 30# ASTM SPECIFICATION FELT: I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 30# ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D226 Type H felt as a component part of an assembly in the Notice of Acceptance. 4. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. NOA No.: 12-0420.02 MIAMMADE COUNTY Expiration Date: 01/25/17 �ffnumeyjgj Approval Date: 10/03/13 Page 4 of 16 INSTALLATION REQUIREMENTS — 30# ASTM SPECIFICATION FELT: 1. 30# ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing 30# Felt. 3. During installation of 30# Felt, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. 30# ASTM Specification Felt shall be installed with a minimum 4" end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or FBC 1518.2. GENERAL LIMITATIONS - EASYLAY: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be1f1* . compliance with applicable building code. .' . • 3. EasyLay shall be applied to a clean and dry surface. .. • • • • • • • 4• EasyLay shall not be torched or hot mopped to. Refer to manufacturer's publishe *oliteratiqfol additional information. : ' • • 5. EasyLay shall not be used on slopes less than 2:12, unless the. slope is acceptable to the wd'hMer resistant covering. In general, on slopes less than 4:12, a double layer of EasyLUa�%%• • • • recommended. • Double layer application is best achieved by using 19" side laps, making sure he side laps are `shingled in' to shed water. • • 6. When installing EasyLay, the roof system must include proper ventilation. ' • • • 7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type H felt as a component part of an assembly in the Notice of Acceptance. 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 9. EasyLay shall not be left exposed for longer than 30 days after application. 10. The manufacturer reserves the right to change product exposure period at anytime; not to exceed the preceding maximum time limitations. NOA No.: 12-0420.02 CMIAMPDAD- Expiration Date: 01/25/17 O • • • • Approval Date: 10/03/13 Page 5 of 16 APPROVED ASSEMBLIES - EASYLAY: System E(1): Anchor sheet mechanically fastened to deck. Deck Type 1: Wood, Non -Insulated. Deck Description: Minimum 19/32" plywood or wood plank. Anchor/Base Sheet: One or more plies of EasyLay underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet). Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type II felt. INSTALLATION REQUIREMENTS - EASYLAY: 1. EasyLay shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing EasyLay. 3 During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. - . 0000 4 EasyLay shall be acceptable for use with asphaltic shingles, wood shakes ana•ehlniles, qy arry slate, tile and metal roofing assemblies. • •' ; .. 5 Re -fasten any loose decking panels, and check for protruding nail heads prior tAft applicatiou of EasyLay. • 6. Place a full width piece of EasyLay, parallel to the eave (low) edge of the rood : • : • 7. Unroll EasyLay 2 to 3 feet, with the lay lines facing up, and position the end of iM%*the edge of the eave and rake. :...:. 8. Install a few fasteners at the top, near the rake, and roll out the sheet to a man'ageAh length... 9. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even witli the eave edge. 10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. 11. When installing nails, apply so that the head of the nail is flush with the EasyLay surface, without cutting into the EasyLay surface. 12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet. 13. Continue on to the end of the substrate and fasten down. 14. Align the next roll over the preceding sheet so as to form a minimum 4" overlap. NOA No.: 12-0420.02 MIAMI•DADE COUNTY Expiration Date: 01/25/17 KAJUROX14"Approval Date: 10/03/13 Page 6 of 16 15. Then install the just placed sheet, per instructions above. 16. The bottom of the second course of EasyLay shall lay on top of the first course so that any water will flow over the top of EasyLay. 17. Apply subsequent sheets in the same manner, with 4" side laps and 6" end laps over the preceding sheets. 18. When the top course is reached, lap about 6" of EasyLay over the ridge. 19. Install EasyLay a minimum of 6" up any vertical surfaces. 20. Stagger the end laps a minimum of 18" from the preceding course. 21. After installing EasyLay on the field of the roof, install drip edge at the eaves (if used). 22. When applying EasyLay in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay. 23. Before applying horizontal sections of EasyLay, install a vertical length of EasyLay down the center of the valley. 24. Several sections of EasyLay can be used, but be certain to overlap the higher sections several inches so any water will flow over the top of the sheet. 25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley lining material. • • • • 26. Apply a minimum 1/16" thick uniform layer of SBS trowel grade modified flishi4cemenf fo • • water proof areas of EasyLay where any cuts or tears have occurred. Seams or J2m maysgVeVr the application of an SBS trowel grade modified flashing cement. 000000 27. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof.E'ISs"l %bly ctlii d. Product Control Notice of Acceptance and applicable Building Code. • • • • • ...... ... . .. GENERAL LIMITATIONS — FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. NOA No.: 12-0420.02 MIAMI•DADE COUNTY Expiration Date: 01/25/17 lFgaz• Approval Date: 10/03/13 Page 7 of 16 INSTALLATION REQUIREMENTS — FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1 Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance listing Fiberglass Mineral Surfaced Roll Roofing as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing Fiberglass Mineral Surfaced Roll Roofing. 3. During installation of Fiberglass Mineral Surfaced Roll Roofing, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. GENERAL LIMITATIONS — ASTM ORGANIC TILE UNDERLAYMENT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. • • •••• •••••• 2. This acceptance is for prepared roofing applications. Minimum deck requirerrieAtS shall be in .' compliance with applicable building codes. .. • •. • **see: • • • • : • 3. All products lined herein shall have a quality assurance audit in accordance wim Me Vlorida • • ; • • • • ; • Building Code and Rule 9N-3 of the Florida Administrative Code. ' ..... .... . .. ...... ... . ..... .. .. .. ...... •.•••. • . . . . ...... . . ...... INSTALLATION REQUIREMENTS — ASTM ORGANIC TILE UNDERLAVMtNT: ; , , • • 1. ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing ASTM Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt, adhesives, fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing ASTM Organic Tile Underlayment. 3. During installation of ASTM. Organic Tile Underlayment, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 8 of 16 GENERAL LIMITATIONS - EASYMOP SBS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water, dew, rain, etc. is present on the substrate. 4. Tarco EasyMop SBS are to be applied to a smooth, clean and dry surface, with the deck free from irregularities. 5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS. 6. Tarco EasyMop SBS shall not be applied over a pre-existing roof membrane or system. 7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 8 All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to slope) as per manufacturer's requirements, not to exceed 6-high, to the standard maximum roof pitch of 5 :12 for flat tiles and 6 :12 for lugged tiles (See Tile Staging Method diagram below). At roof slopes greater than the above limitations, the use of loading battens or toe boards are required to load the roof tile. *Sao*, Front View - Staged Tiles (Slope —>) Tile Staging Method • i Side View - Staged Tiles (Slope 1) 9. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 9 of 16 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of an assembly in the Notice of Acceptance. If Tarco EasyMop SBS or the TAS 104 standards are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire testing results. 12. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. APPROVED ASSEMBLIES — EASYMOP SBS: System E(1): Anchor sheet mechanically fastened to deck, membrane adhered with hot asphalt or approved adhesive. Deck Type 1: Wood, Non -Insulated. Deck Description: Minimum 19/32" plywood, wood plank. `.... ` ...... Anchor/Base Sheet: see One or more plies of ASTM D226 Type II or ASTM D2626 W44 a minihmxt4' • • • • • wide side lap and a minimum 8" wide end lap, mechanically €a4ened to deck. ; • , • . ; Fastening: •..• . Approved nails and tin caps 6" o.c. within lap and two equa,ed st'�;A4!d Ajy� ..... rows 12" o.c. in the field (for Anchor/Base sheet only). ...... ... . • ..... Membrane: •• • •• EasyMop SBS applied to Anchor/Base Sheet with hot aspQj p: vjith approved •••••• . • adhesive as specified in RAS 118, 119 or 120. • (See #13 in Installation Requirements for back nailing) •• • • .. • Surfacing: Approved Roof Assemblies as specified below. "" NOA No.: 12-0420.02 MIAMFUADECOUN7Y Expiration Date: 01/25/17 • • • l Approval Date: 10/03/13 Page 10 of 16 INSTALLATION REQUIREMENTS - EASYMOP SBS: 1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations (NRCA) when installing EasyMop SBS. 3. During installation, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. EasyMop SBS shall be an acceptable underlayment for mechanically fastened roof the and adhered roof rile applications. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyMop SBS. 6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the EasyMop SBS. Refer to applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate withAilm ....., D 41 primer. 9. Applicator may cut EasyMop SBS into sections for workability and allow to!re1&*x prior to application. 10. .... .. Place EasyMop SBS over metal drip edge in accordance with RAS 111. ...... ... . ..... 11. Install the first course of EasyMop SBS parallel to the eave edge. ..' ..' ' 00 0 0 0 0:0 12. It is recommended that end laps be staggered a minimum of 18" from the precedinj course. ' ' . 13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, I I -gauge 11/4" approved • ring shank type applied with a minimum of a 15/8" approved tin cap or approvedcMnail 4s . • • . 0 0 required per the High Velocity Hurricane Zone (HVHZ) section of the FBC, at a minimum We of 12" o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 14. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 15. Vertical strapping of EasyMop SBS membranes is acceptable. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 11 of 16 GENERAL LIMITATIONS — TARCO SELF -ADHERED UNDERLAYMENTS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco self adhering underlayments shall be applied only when material interface temperatures are 400 F and rising. 4. Tarco self -adhered underlayments shall not be installed when any form of moisture such as water, dew, rain, etc. is present on the substrate. 5. Tarco self -adhered underlayments are to be applied to a smooth, clean and dry surface, with the deck free from irregularities. 6. Ensure roof has positive drainage prior to installation of Tarco self -adhered underlayments. 7. Tarco self -adhered underlayments shall not be applied over a pre-existing roof membrane or system. 8. After installation of Tarco self -adhered membranes, wait a minimum of 48 hours before roof loading of tiles. * 0 0 * 9. Care should be taken during the loading procedure to keep foot traffic to a mihinw% and aVM& dropping the roof covering directly on the underlayment. • ...... .. .. 10. All tiles shall be staged (two tiles perpendicular to slope, four tiles on top parallel to► slope) as per manufacturer's requirements, not to exceed 6-high, to the standard maximum jeef pitch of 6 � 12 for flat tiles and 6 :12 for lugged tiles (See Tile Staging Method diagram below • • • • • At roof slopes greater than the above limitations, the use of loading battens oro 0 0 09ards are . 0 required to load the roof tile. : • Tile Staging Method • • • • • • . . Front View - Staged Tiles (Slope -->) Side View - Staged Tiles (Slope 1) 11. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. MIAMI•DADE COUNTY �LIWU.• NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 12 of 16 12. EasyLay, PS200uU MS300, SS400, and NR50eTshall not be left exposed as a temporary roof for longer than 30 days after application. PS200Hr shall not be left exposed as a temporary roof for longer than 120 days after application. Fast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. 13. NR500HT is not recommended for extreme high temperature environments such as under copper or zinc metal roofing. 14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco self -adhered underlayments may be used with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM standard which the self adhering underlayments meet as a component part of an assembly in the Notice of Acceptance. If Tarco self -adhered underlayments or the ASTM standards are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product, wind uplift resistance, and fire testing results. 15. All products lised herein shall have a quality assurance audit in accordance with the Florida . • • Building Code and Rule 9N-3 of the Florida Administrative Code. '....' ...... ...... .. .. ...... APPROVED ASSEMBLIES — TARCO SELF -ADHERED UNDERLAYMENTy�, • ; • • • , • • • • • System E(1): Anchor sheet mechanically fastened to deck, membrane adhtted.; .. • • ; 00000 .. • • • .. • .. Wd, Non -Insulated. Wood, on - Deck Type l: • • ..... . • •.. . . . . Minimum 19/32" plywood, wood plank. """ Deck Description: .' . .... ; .... ; 00 • One or more plies of ASTM D226 Type 11, ASTM D2626, or EasyLay 0. ; • Anchor/Base Sheet: . , underlayment, with a minimum 4" wide side lap and a minimum 8" wide end lap, mechanically fastened to deck. Fastening: Approved nails and tin caps 6" o.c. within lap and two equally spaced staggered rows 12" o.c. in the field (for Anchor/Base sheet only). Membrane: All Tarco self -adhered membranes applied to approved Anchor/Base Sheet. (See #15 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 13 of 16 System F(1): Membrane self -adhered to concrete deck. Deck Type 3• Concrete, Non -Insulated. Deck Description: Structural concrete or concrete plank min. 2500 psi. Deck Preperation• The concrete deck shall be clean and dry and cured for a minimum of 28 days. Anchor/Base Sheet: None Fastening: Membrane shall be back nailed with approved concrete fasteners and 15/8" approved tin caps at a maximum spacing of 9" o.c. at the head laps and be covered by the preceding layer. No back nail fasteners or tin caps shall remain exposed. Membrane: Tarco PS200HT self -adhered membrane applied directly to concrete deck. (See Fastening above for back nailing) Surfacing: Approved Roof Assemblies as specified below. INSTALLATION REQUIREMENTS — TARCO SELF -ADHERED UNDERLAYMENTS:• • • • 1. Tarco self adhering underlayments shall be installed in strict compliance with.ppltcable $uildipg • 2. Codes. .••••. OGG .. Observe and comply with roofing practices and guidelines as outlined by theWafiohal Roofing •.••.• :Gee*: Contractors Associations (NRCA) when installing Tarco self adhering underiaXrn` fits. • • • • • • • 3. During installation, comply with Occupational Safety and Health AdministrattV f4SHA) safety • • • • standards; use common sense measures and adequate safety precautions to pfdvdtft accidents. 4. Fast90 and PS200HT shall be acceptable underlayments for mechanically fas&ne$ roof the and. .....0 adhered roof tile applications. MS300 and SS400 shall be acceptable underlpments for asphaltic • shingles, wood shakes and shingles, and slate or simulated slate roof assemblies. A200`.0 O.d. • NR500HT shall be acceptable underlayments for asphaltic shingles, wood shakes, shingles,VrAf metal roof panel assemblies. 5. Re -fasten any loose decking panels, and check for protruding nail heads prior to the application of the Tarco self adhering underlayments. 6. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing, valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer, water based acrylic or water based polymer modified primer. 9. Contractor may cut the underlayments into sections for workability and allow to relax prior to application. 10. Place the underlayments over metal drip edge in accordance with RAS 111. 11. Install the first course of underlayment parallel to the eave edge. 12. Apply the underlayment, working from the center of the material continuously to the ends of the sheet (half of the length of the sheet is the center); taking care to avoid wrinkles and ridges. NOA No.: 12-0420.02 Expiration Date: 01/25/17 Approval Date: 10/03/13 Page 14 of 16 13. Remove the underlayments release film rapidly in a continuous fashion. Ensure the bottom adhesive side of the membrane does not adhere to its self In the event this transpires,separate the two layers immediately. After some time, it may become impossible to do so without damaging the material. 14. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 15. Underlayments are to be back nailed along the head lap. The nails shall be, 11 gauge 11/4" approved ring shank type applied with a minimum of a 15/8" approved tin cap or approved capnail as required per the High Velocity Hurricane Zone (HVHZ) section of the FBC, at a minimum rate of 9" o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 16. Roll or broom the entire membrane surface paying special attention to all overlap areas "side laps, end laps, T joints" to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for steep slope applications. The use of a soft bristled push broom is acceptable on steeper slopes. The above mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the membranes. 17. Apply'/8" thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive / flashing cement throughout the contact area of the 6" granule over granule and fabric over fabric end laps. Once the aforementioned procedure has been completed, the membrane must then be hano*Mle� in place in order to ensure contact of membrane and achieve a minimum of 1Y8 % Asphaltic•lslMd .. • • . •' •' ; • • out in designated area. • 18. 000000 Tarco self adhering underlayments shall be applied to protrusions, slope chamges,•aalleys, curbs, and other roof top penetrations before any other sections of the roof. • • • • • • • • • • 19. .... . .. When applying underlayments in the valley, start at the low point and work tv Z: high ppi]Qt, . ..... .. ; .. • rolling the membrane from the center outward in each direction. • • • • • . ..•... 20. For ridge applications, center the underlayment and roll from the center ouh;iYc;irmboth • directions. 21. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Atsethbly CIrTift. 0 • Product Control Notice of Acceptance and applicable Building Code. 0000 22. All protrusions or drains shall be initially taped with a 6" piece of like kind membrane. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind membrane shall be applied over the flashing detail. 23. Vertical strapping of Tarco self adhering membranes is acceptable. NOA No.: 12-0420.02 F- Expiration Date: 01/25/17 C�Wjaztfngj Approval Date: 10/03/13 Page 15 of 16 MANUFACTURER'S CONSIDERATIONS: When using Fast90 and PS200HT in tile roofing applications, use of loading battens or toe boards on roof slopes greater than 6:12 and higher is recommended. When using EasyMop SBS in tile roofing applications, use of loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher is recommended. Code body requirements supersede manufacturer's recommendations and installation guidelines. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of these materials. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" ortbe. Miami -Dade County Product Control Seal as shown below. • • • • • MIAMMADE COUNTY *:*:so ,.• • • • . i ..� END OF THIS ACCEPTANCE • • • •.• • •• NOA No.: 12-0420.02 MIAMMADE COUNTY Expiration Date: 01/25/17 �uumermll Approval Date: 10/03/13 Page 16 of 16