Loading...
RF-19-499Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address 384 NE 94TH ST, Miami Shores, FL 33138 Contacts Issue Date: 03/07/2019 Parcel Number 1132060136140 Permit No.: RF-03-19-499 Permit Type: Roof Work Classification: Tile Permit Status: Approved Expiration: 09/03/2019 PENN DAVIS Owner T&S ROOFING SYSTEMS INC. Contractor 54 NW 94 ST, MIAMI SHORES, FL 33138 LOUIS TOLEDO Other: 3057510325 1461 NW 23 ST, MIAMI, FL 33142 Business: 3052652654 Other:3057727954 Description: RE -ROOF TILE Valuation: $ 51,000.00 Inspection Requests: 762-4949 Total Sq Feet: 6,000.00 Fees Amount Application Fee - Other $50.00 CCF $30.60 DBPR Fee $5.63 DCA Fee $3.75 Education Surcharge $10.20 Roofing Fee $325.00 Scanning Fee $9.00 Technology Fee $9.38 Total: $443.56 Building Department Copy Payments Date Paid Amt Paid Total Fees $443.56 Check # 35876 03/07/2019 $443.56 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNER FFIDAVIT: I rtify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulati g con uction zo _ ing. Futhermore, I authorize the above %nedntractor to do the work stated. Ic �� .5 r �Z0Iq Authoriz - nature: O er / Applicant / Contractor Agent Date March 07, 2019 Page 2 of 2 i ACB2 Engineering Inc. Testing & Engineering Services Certificate of Authorization # 8131 Tel: 954-245-8976 Fax: 954-301-7776 5230 NE 18TH Avenue Fort Lauderdale, FL 33334" Roof Tile Uplift Test Report Attention: Miami Shores Village, Building Division, 10050 NE 2nd Avenue, Miami Shores, FL 33138 Client: T&S Roofing Test Date: 07/22/2019 Permit # RF-03-19-499 Property Address: 384 NE 94 Street, Miami Shores, FL Roof Pitch: Type of Tile: Roof Area: 4 in 12 Santa Fe Roof Tile 60.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro H 160 Field Instrument : IMADA Force Gauge 0-100 Serial number: 243454 Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: (T1-T20) 20.00 sq. 20 As per FBC 2017 Passed Field Area: (T21-T60) 40.00 sq. 40 As per FBC 2017 Passed No. of Corner (T61-T86) 26 26 As per FBC 2017 Passed Ridge Areas: (T87-T101) 150 PCs 15 As per FBC 2017 Passed Important: These laboratory results can change due to future weather impacts and/or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordially, eering Inc. (NOA 09-1005.01) Acevedo, PE No: 36466 0-�/Z4 20/? • • Im Fed Lse�m---s-l-.FJod&M34 .. �2 P2 125 F=c ((954)3-0l 7 )6 QS F4- r3 I 12 - $-9 .' 5 - 3 � 29 I $ 3-0 NN 2� ., 2S V >S3 -3 BUILDING PERMIT APPLICATION Miami Shores Village Building Department RECEIVE® 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 MAR 0 i 10;9 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201-- Master Permit No. �f - 02 "1�� Sub Permit No. r-IBUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: City: Miami Shores — 1 1 N [ u County: Miami Dade Zip: ?j-IR Folio/Parcel#: �\_ _M I Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titlehold ): Vqy) ) Phone#: Address: A��(� /_ C t City: M i� m'% 2 O I Q J State: L Zip: _ J1 39 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Address: NO N W 2. City: Qualifil Name: State Certification or Registration #: cG­jcIV ne#: —3Gj _State: �� Zip: Phone#: 2 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ I QQd Square/Linear Footage of Work: �CJCJ Type of Work: ❑ Addition ❑ Alteration� ❑ New ElRepair/Replace ❑ Demolition Description of Work: a Poo ( I l '( Specify color of color thru tile: a e ( f () (,0i'1 Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Structural Reviews $ Training/Education Fee $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) , Borlding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip, Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. * Signature �� — Signature OWNER or AGENT The foregoing instrument was acknowledged before me this day of a 20 by J 1 S who is personally known to me or who has produced as CONTRACTOR The fgregoiinenstrument was acknowledged befor a this /�J day of 9 a (C�- 20 by G who is personally known to me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PU Print: *********** Zoning (Revised02/24/2014) Structural Review Clerk 3/7/2019 Property Search Application - Miami -Dade County 41 ONFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-013-6140 384 NE 94 ST Property Address: Miami Shores, FL 33138-2832 PENN E DAVIS TRS PENN E DAVIS REVOC LIVING TR Owner MICHELLE S CANERO TRS MICHELLE S CANERO REVOC LIVING TR 384 NE 94 ST Mailing Address MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ 0101 RESIDENTIAL - SINGLE Primary Land Use FAMILY: 1 UNIT Beds / Baths / Half 5/5/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 5,875 Sq.Ft Lot Size 25,400 Sq.Ft Year Built 1925 Assessment Information Year 2018 2017 2016 Land Value $761,638 $761,638 $635,034 Building Value $285,525 $285,525 $285,525 XF Value $19,082 $19,082 $19,082 Market Value $1,066,245 $1,066,245 $939,641 Assessed Value $819,262 $802,412 $785,908 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $246,983 $263,833 $153,733 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,0001 $25,0001 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOTS 1 TO 4 INC BLK 46 LOT SIZE 200.000 X 127 OR 9909 1258 1277 3 Generated On : 3/7/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $769,262 $752,412 $735,908 School Board Exemption Value $25,000 �$25000$25,000 Taxable Value $794262 $760,908 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $769,262 $752,412 $735,908 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $769,262 $752,412 $735,908 Sales Information OR Previous Price Book- Qualification Description Sale Page 01/28/2017 $100 30407- Corrective, tax or QCD; min consideration 2489 07/17/2012 $740,000 28191 Qual by exam of deed 3475 09708- Sales which are disqualified as a result of 03/01/1977 $1 1763 examination of the deed 00000- Sales which are disqualified as a result of 02/01/1976 $1 00000 examination of the deed The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the 9"ervith the required roofing permit, and to explain to the owner the content of the section. The ly'ovigibps of Se"M R4402' • • •; • govern the minimum requirements and standards of the industry for roofing system installation?. Additidnally;the '. following items should be addressed as part of the agreement between the owner ant the Mractor. The initial in the designated space indicates that the item has been explained. `•"• owner's ' .... .... . . .... .... ...... ... ..... . 2. Renailing wood decks: When replacing roofing, the existing woed roof`deck may 6ieve to ..... 0 • .... be renailed in accordance with the current provisions of Section R4403. (The rq *tt is usually • • concealed prior to removing the existing roof system). 0 0 0• • • • • • 2�4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. `J.-Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimetededge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. iIA'a' ent's Signature Date Co tr for Signature Date Property Address Revised on 7/9/2009 LD;07/01/2015; Permit Number Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERTS AFFIDAVIT OF EXEMPTION 0000 ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR f.XL&JING SITE4- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES ...... PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 3313ti Re: Owner's Name: Property Ad Roofing Permit Number: ...... ...... .... .... . . • D;te a� . . . . ...... .... % Dear B�Tq g Officia I r certify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edif of the South Florida Building Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large gpAmy t!— N `suR�1 20G 2.0762 C001331pN5,2022 9TVPE3:01 nrcUnd • When the just valuation of the structure for p of ad valorem taxation is equal to or more than $300,000,00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 2/14/2019 Property Search Application - Miami -Dade County OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-013-6140 384 NE 94 ST Property Address: Miami Shores, FL 33138-2832 PENN E DAVIS TRS PENN E DAVIS REVOC LIVING TR Owner MICHELLE S CANERO TRS MICHELLE S CANERO REVOC LIVING TR 384 NE 94 ST Mailing Address MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ 0101 RESIDENTIAL -SINGLE Primary Land Use FAMILY: 1 UNIT Beds / Baths / Half 5/5/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 5,875 Sq.Ft Lot Size 25,400 Sq.Ft Year Built 1925 Assessment Information Year 2018 2017 2016 Land Value $761,638 $761,638 $635,034 Building Value $285,525 $285,525 $285,525 XF Value $19,082 $19,082 $19,082 Market Value $1,066,245 $1,066,245 $939,641 Assessed Value $819,262 $802,412 $785,908 Benefits Information Benefit Type 1 2018 2017 2016 Generated On : 2/14/2019 Taxable Value Information 2018 201 22016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $769,262 $752,412 $735,908 School Board Exemption Vale • •: : : • • $2�i3OBO • • $25,000 $25,000 Taxable Value •. •: ; ; ; 3*079:,2$2 • • $777,412 $760,908 City Exemption Vilye ... • • $50,000 • $50,000 $50,000 Taxable Val•!@ • • + : *69,2k : :$752,412 $735,908 . • •• . • . . • • Regional . . . • • • . • • Exemption Value $50,000 $50,000 $50,000 Taxable Value*:* Ip7ft,42 $752,412 $735,908 . .. .. . . . .. .. Sales Information. ... . ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) i High -Velocity Hurricane Zone Uniform Permit Application Form. 1 1 Section A (General Information) 1 1 Master Permit No. Process No. 1 1 Contractor's Name's .... 1 Job Address 21� . . .... .. ... I.. • ...... .. .. ... .. ROOF CATEGORY •••••• 1 • ❑ Low Sloe "" "" P ❑ Mechanically Fastened Tile MortarlfgjiDVV1e Set Tiffs„ • • O Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood SK09lef/Shak25• •, ,,,1, • • 0 1 • ❑ Prescriptive BUR-RAS150 " " " "'j;' ROOF TYPE • • • • •..�.• New roof ❑ Repair ❑ Maintenance ❑ Reroofing , El Recovering ROOF SYSTEM INFORMATI 0 : . 0 •. 0 1 ' Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF)M Total (SF)_L6" 1 i Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 i ME ME■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■ MEMO MEN■M■MA■r/)�7■■■■■■■■■■■MEN ■■■■■M■L.�MNONE /�■■■M■■■ IN ME ME No ONEMENE ON: Now go No MEN ME ME ME MEN No NONE ME No MEMO so ■■■■■■■■■■■■■ MEN so M M IN ONE ■MMOMEN OMOE■MIMEN ■M■MOM■■ MENIMM■M■MO■EEMMEN ■OMEN M■■ ■■■■■■■■�■■■■■EMEN E■■ FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 r I I I ' CoPyrigbt to, or licensed by. ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to license Agreement. No further reproductions authorized. 1,26,AEAGLErIEW Y LLI V V 1 fl UJLM%JRhU"I Total Line Lengths: Ridges = 157 ft Hips =79ft Premium Report 1/18/2018 Claim: Libutti Valle 4 Flashing = 173 ft` R E C E � � f ED Rakes = 278 Step flashing = 168 ft Eaves = 754 ft Parapets = 148 f'AP 6 I -wnr have been removed for readabilitV.'�PIUs signs preface some -numbers to avoid confusion when rotated (e.g. +6 and +9). m O 2008-2018 Eagle'Aew Technologies, Inc. and Pictoetry International Corp. — All Rights Reserved — Protected by European Patent Application No. 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 4 - r Mlama-Dade County HVHZ Electronic rloof {ParnO Form 1 Section D Tile Roof System (%Ji31 ✓e';df: i.`��ience Ev r f� f lit , Roof System Manufacturer: ISAN I A FE TILE CORP ^� Notice of Acceptance Number (NOA): Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): 1100.7 P 1: 39.1 P 2: 68.1 P 3: . . .... ...... Maximum Design Wind Pressures, (From the NOA Specific system): �61.9 psf •. •: • • •. • • """ Fiji in fife specific roof assen7bly componen;`s. ifa comoonant is not regwire-J, ins er i noL applicable a text bp,;c,. � • • • • • I - .... .... .. Deck Type: -5/8 Plywood.. ..... ..... _ _;= • •�'; _ .. i .. Optional Insulation: • • • • • • 0 0 0: ,1Optional Nailable Substrate: - — Optional Nailable Substrate Attachment: Roof Slope: 712" Roof Mean Height: ,15_.. ft. Method of Tile Attachment: -Adhesive, Medium Paddy Polyfoam Polypro- o� Alternate Method of Tile Attachment per NOA: i Drip Edge Size &Gauge: '--3" fiace 26 ga.-- Drip Edge Material Type: 1--Galvinized Metal-- Drip Edge Fastener Type: 111 1/4 RS NAILS Hook Strip/Cleat gauge or weight: `--Select Hook Strip -- Basesheet Type: #30 ASTM TYPE If Fastener Type for Basesheet Attachment: 1',11 1/4 RS NAILS 6" OC AND 12" FIELD Tile Underlayment (Cap Sheet) Type: 'BORAL TILE SEAL — I Tile Underlayment•Attachment Method: SELFADHERED Tile Profile: SPAN1SH "S" �,,jx ai-lhg, Eyce!feyi ce Every Day" Miami -Dade County FgVHZ F-orm - Section E (Tile Calculations,3 Method I "Moment'Based Tile Calculations P-ar RAS 127" For Moment based tile systems, use Method. 1. Compare the values for Nirvith f.1-16 values from Mf. if the Mf values are greater than or equal to the Mr values, for each area of the'roof, then the tile attachment method is acceptable. P 1: XX Mg: Mr 1: [-5 < NOA*%f. . ...... Mg: IV, r2-: 53-1:511 NOA"i... 0 P 2: x XEI EE - ...... 0000 *000 0 Zj il 00.7 Mg: Mr3-: i6i .9. NOAU. o o •... so o..o. P 3: x 1 0 00:09: 0 000:::::o Method 3 "Uplift Based Tile Calculations Pe67 RAS 127" ::.::o so* so : o : 6, o e*oo:o ' the F'v,a1L10 are greaterthen or equal to Velflrovglues, fQr or Uplift based tile systems use Method 3. Compare the values for F'Vith the values for Fr. 11 o )@ch area of the roof, then the tile attachment method is acceptable. Cll,. so 6 so :Goes: a o o*oo x 1: x w: -W. x C-os 0: Frl: NOA P x w: -W: x Cos e: NOA F x W.- -W: I = x Cos 8: 'Fr3: NOA F Where to Obtain Information to complete tile, calculations IVYKere t6 Find Description SYM601 Table I RAS 127, or by an engineer analysis- prepared, signed and sealed by a professional Design Pressure P1 or P2 or P3 engineer based on ASCE 7. Mean Roof Height Hi Site Roof Slope —Pob-Slte Aerodynamic Multiplier Produc"Approval (NOA) Restoring Moment due to Gravity M - Product Approval "(NOA) 117- Attachment Resistance Mf -.Proeluc'C��pprt?v al -(NOA) ,Rpqulred Moment Resistance Mr 'Calculated' Attachment Resistance A111rd-murn Att F' — Pro I �hu Approval (NOA) Ra:aired Uplift Resistance Fr Average Tile Weight W Prdddct-Approval (NOA) Tile Dimensions I length Produc.Fxpproval (N'OA) w = width M I® DiADE MIAMI-DADE COUNTY � PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economv Santafe Tile Corporation 8825 NW 95' Street Medley, FL 33178 sees . . ee.e SCOPE: .eeeee � • This NOA is being issued under the applicable rules and regulations governing the use of construction rnatesia:s. The documentation submitted has been reviewed and accepted b Miami -Dade County RER - Go**** o • • t Control �ecfion to • p Y tY i4S�� . o be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction AH • • • • • • .... .... ..... This NOA shall not be valid after the expiration date stated below. The Miami -Dade County.RwAict Cgpgol $ectiorl,:,, • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve tke sight to have'th:s Osseo* product or material tested for quality assurance purposes. If this product or material fails to.Tei faV in the accepted e manner, the manufacturer will incur the expense of such testing and the AHJ may immediately reltoke, tppoit, or • • • • o • suspend the use of such product or material within their jurisdiction. RER reserves the riglt to -(evoke this :....: acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material'fails to • soee meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish `S' Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 15-0915.09 and consists of pages 1 through 5. The submitted documentation was reviewed by Freddy Semino N MIAMFDADE COUNTY NOA No.: 18-0604.04 Expiration Date: 02/01/21 Approval Date: 08/02/18 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Clay Deck Type: Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in SectioigZQf this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable*RYilding ...... Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 12' us irr:g the • • values listed in section 4 herein. The attachment calculations shall be done as a momeilf Wed systeftf. • • • • • • • • .... .... . . . PRODUCT DESCRIPTION .... ..... . ... . Manufactured by Test Pro ufit•.... . ..... • • 0 : 0 • Applicant Dimensions Specifications Desczip" • Santafe `S' Clay Roof L = 18" TAS 112 One piece high profile clap roof tile eqp��with ...... Tile W = 11.1 " Type I two nail holes. For nail-o$, mortar set'and adhesiv$ . . , • Thickness = 0.39" Grade 1 set applications. Trim Pieces 1= varies TAS 112 Accessory trim, clay roof pieces for use at hips, w = varies rakes, ridges and valley terminations. Manufactured varying thickness for each tile profile. 2.1 MANUFACTURING LOCATION 1. Bogota, Colombia 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, Inc. 94-156-8 TAS 101 Aug. 1994 94-156-9 TAS 102 The Center for Applied Engineering, Inc. 25-7205-1 TAS 101 March 1995 The Center for Applied Engineering, Inc. Project: 07-07-00-91 TAS 100 Sept. 1994 (307023) Redland Technologies 7161-03 TAS 108 Dec. 1991 Appendix II (Nail -On) Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix HI TAS 102 & TAS 102(A) Redland Technologies P 0402 Withdrawal Resistance Sept. 1993 Testing of Screw vs smooth shank nails Redland Technologies P 0647-01 TAS 108 Aug. 1994 (Mortar Set) NOA No.: 18-0604.04 M'AMI•DADE COUNTY Expiration Date: 02/01/21 Approval Date: 08/02/18 Page 2 of 5 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date Redland Technologies P 063 1 -01 PA 108 July. 1994 (Mortar Set) Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 IBA Consultants, Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants, Inc. 2353-70 TAS 101 t9lg2/03 . . .... ...... IBA Consultants, Inc. 2353-71 TAS 101..' . 09/2.2/03 IBA Consultants, Inc. 2353-93 ASTM C 1 MI : • � ' 1 71?8/05 .... • • American Test Lab of South Florida RT0624.01-15 ASTM C1167.03 • • • • Ur7101/15 PRI Construction Material Technologies COPO-002-02-08 TAS 101 .... • 14f2/16 • •... • ... • • 0090 • • I • • . • • • • • • • • • • • • 3. LIMITATIONS • • • • • • ' • • 3.1 Fire classification is not part of this acceptance. • • • ... ...... 3.2 For mortar or adhesive set the applications, a static field uplift test shall be peff�ot'In�d in apco;dance w•t't• • • TAS 106. • 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations NOA No.: 18-0604.04 MIAMM)ADECOUNTY Expiration Date: 02/01/21 6 1 Approval Date: 08/02/18 Page 3 of 5 Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Santafe 'S' 6.7 1.5 0.958 Table 2: Aerodynamic Multipliers— %(ft3) Tile Profile ). (ft3) Batten Application (ft) Direct Deck Santafe 'S' 0.274 0.297 . Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf) ' ...... .. .. Tile Profile 2":121' 3"•12" 4"•12" 5":12" 611.4-A• ••••• 7":12" or. 0. •gre ter • Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens• •• "rect k Bdtt M ••• Direet- Deck• Santafe 'S' 5.93 5.90 5.85 5.82 5.73 5.69 1 5.56 5.53 1 5.32• • -3.29 5.03• • 5.09• Table 4: Attachment Resistance Expressed as a Moment - Mf (ft.-10 for Nail -On Systems • • • • • • - •Affens Tile Profile Fastener Type Direct Deck Santafe 'S' 2-10d Ring Shank Nails 21.8 N/A One #8 Screw 29.16' 2 N/A Two #8 Screws 38.28' N/A One #8 Screw w/ Clip 57.311.2 1 N/A Two #8 Screws w/ Clip 57.60' 61.77' 1. Approved screws as noted 'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application 2 Minimum Attachment Resistance Santafe 'S' Tile Bond 38.93 Polyfoarn Polypro AH 160TM 33.1 4 2 See manufactures component approval for installation requirements. 3 Flexible Product, Inc. Average weight per patty 10.4 grams. 4 Polyfoarn Product, Inc. Average weight per patty 9.4 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application 2 Minimum Attachment Resistance Santafe 'S' Polyfoarn Polypro AH 160Tm 66.55 Polyfoam Polypro AH 160'rm 63.8 6 DAP Foam Touch N Seal Storm Bond 2 1007 5 Paddy placement of 63 grams of Polypro AH 160Tm. 6 Paddy placement of 24 grams of Polypro AH 160TM. 7 Paddy placement of 45 grams DAP Foam Touch N Seal Storm Bond 2 NOA No.: 18-0604.04 Expiration Date: 02/01/21 Approval Date: 08/02/18 Page 4 of 5 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Santafe 'S' Mortar Set 23.6 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami -Dade County Product Control Approved". sees SANTA FE TM MADE IN COLOMBIA:•:•: •••�:• see:se ee ee sees.. sees.. LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE • • • • e e e e :so**: sees ssse sees• e.:..• 6. BUILDING PERMIT REQUIREMENTS sees.. ... s ee ee e• sees.. 6.1 Application for building permit shall be accompanied by copies of the followint! •: •: • • • sees.. 6.1.1 This Notice of Acceptance. sees.. 6.1.2 Any other documents required by the Building Official or applicable buildingscode Inorder to %s e e properly evaluate the installation of this system. 0009 • • PROFILE DRAWING "SANTAFE S" CLAY ROOF TILE END OF THIS ACCEPTANCE When using one screw 3e this hole. NOA No.: 18-0604.04 Expiration Date: 02/01/21 Approval Date: 08/02/18 Page 5 of 5 M!®D�ADE MIAMI-DADE COUNTY � PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 .... . . .... ...... SCOPE: •. This NOA is being issued under the applicable rules and regulations governing the use of c8iftn etion materials. Tha • • • :. documentation submitted has been reviewed and accepted by Miami -Dade County RER - Pfddi%'t'Control Section tol).e� used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiclioo FAHJ).0*00 This NOA shall not be valid after the expiration date stated below. The Miami -Dade CountyVro%ct COn'lrol Sectiorf (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve moat * to have tl iss 0 * ":' product or material tested for quality assurance purposes. If this product or material fails to;perfoi:n in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, 1315fly'ffor suspend the use of such product or material within their jurisdiction. RER reserves the right -to revoke tki lac+,�eptanae, if it is determined by Miami -Dade County Product Control Section that this product or material fails to inset the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description •••• BORAL TileSeal 36" x 36' rolls TAS 103 SBS self -adhering asp%alt Sheet maierial with a ...... 36" x 72' rolls ASTM D1970 white glass re -enforced DblydSter stgfajintig fabric; • • for use as an underlaymen$ iri sloped l bot* • • • • • • assemblies. ....: • • • • • • • • • • • Boral Citadel Plus 36" x 72' rolls ASTM D1970 SBS self -adhering aspta*'t et mate:aNith a 00 0. untjlaymgn ,poly flm-facer; for use aS chd-plye ••• in sloped roof assemblies,,... • MANUFACTURIGN LOCATION: • . . •••••• 1. Brentwood, NH. .... 2. Houston, TX. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials OCF-356-02-04 ASTM D1623 07/25/18 Technologies, LLC. OCF-356-02-02 TAS 103 07/24/18 OCF-356-02-01 ASTM D1970 07/26/18 OCF-424-02-04 ASTM D1623 07/25/18 OCF-424-02-01 ASTM D1970 07/25/18 OCF-424-02-03 TAS 103 07/25/18 Trinity ERD BRLRF-SC16810.11.17 ASTM D 1876 11/28/17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Ply Sheet . . .... ...... Apply one layer of Boral Citadel Plus over Base sheet as per current apprOval. . • (Optional) • • • • • • • .. .. ...... Membrane: One or more plies of BORAL TileSeal Underlayment with a minimu o *T'ohead 1alimd • minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release memb;q%:; the membWo e is 0 0 * * 6 applied. Vertical strapping of the roof with BORAL TileSeal Underdayment is acceptable. All • end laps and laps without black selvage area shall be sealed under ;ap using an FbBS modified...:. mastic. 0.0 Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back'nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. ." 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer t11av78V days 9f •, 00 • • application. ... 0 .. ... ... , • 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 wheel 14? Are loaded'directly ; to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitchJ `&-xater than &12". • 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this prpcduct yvith •, ; • . . specific prepared roofing products. • • • • .. ...... 8. Tiles shall be stored on battens on roof pitches greater than 6:12". • 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of. cceptance ig"i- BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If UORAL :go*-,: TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ}6619e Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below MIAMI•DADE COUNTY • END OF THIS ACCEPTANCE NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 4 of 4 MIAMI-DADE COUNTY WAKIC- M- PRODUCT CONTROL SECTION a 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.nuanudade.eov/economv ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of eonstraction rnate'rials. TIl8' `; • documentation submitted has been reviewed and accepted by Miami -Dade County RER -Prp� Vjtr �ontroi Sect ;on to be • used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiay.14"HJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade Coun4*Pr6duct Wi trBL Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve tt� ` to have V1s product: or material tested for quality assurance purposes. If this product or material fails to perform ja%e. acceptedd iWer, tbi: manufacturer will incur the expense of such testing and the AHJ may immediately revoke, amod+ or suspend the use • of such product or material within their jurisdiction. RER reserves the right to revo;e t6-i acceptance, if it.is.. ; . determined by Miami -Dade County Product Control Section that this product or material falls tpVeet the requirements• of the applicable building code. ; , .. • .... This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile sgsterrls usingd•.*Goo• • Adhesives Polyset® AH-160. • • . ...... .. •• ...... PRODUCTS MANUFACTURED BY APPLICANT: • • • • • �i.•J ••..•• Product Dimensions Test Produ&Dcsdriytiol • Specifications .. • • • • ICP Adhesives N/A TAS 101 Two component polurethane foam'�dhesi• •; • . .... Polyset®AH-160 • ICP Adhesives Foam N/A Dispensing Equipment • • • • Dispenser RTF1000 • • s ICP Adhesives ProPack® N/A Dispensing Equipment 41.6 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Proper Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158'F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMMADE COUNTY Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 . OA1714 Polymers Division '..' .... ••.•.• 00 • • • �� Ramtech Laboratories, Inc. 9637-92 ASTM E 108 • • • • 04/30193 • Southwest Research Institute 01-6743-011 ASTM E 108 01-6739-062b[l] ASTM E 84 :••: Oim9: ••�••• .. .. .. ...... Trinity Engineering 7050.02.96-1 TAS 114 ; • • • •; 0�114/96 P36700.04.12 ASTM D 1623 . (Iy�8�12 �••"' P39740.02.12 TAS 101 •••• W-12I/l2 ;••••� TAS 123 ' Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset' AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset AH-160. 2. ICP Adhesives Polyset AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset' AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Bggl�lgt. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed 4y IC,%Adhesives and ...... Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators' to t1fe autho?ity hiving • � � 0 � • jurisdiction. • ...... . 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is reguime befor a application: " of any adhesive. The mix ratio between the "A" component and the "B" component shalt be maintained�3tween• . • . • ...... ... . ..... .. .. .. ..... . 6. ICP Adhesives Polyset' AH-160 shall be applied with ICP Adhesives Foam Dispenser RTE 1000 or ICP. . • • Adhesives ProPacke 30 & 100 dispensing equipment only. • . . . ..... . 7. ICP Adhesives Polyset AH-160 shall not be exposed permanently to sunlight. :....: 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP ,?4d1;osives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset' AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 1.2 grams }yes faddy .. head of file 9-11 sq. inches at • • • overlap "" • • • • • • • Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal • • • 4 7 granpparibead edge) 20-25 sq. inches each 11666 see** • • bead ""' " • • • Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches •' :Yt grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 MIAMFDADE COUNTY ... � , Expiration Date: O5/10/22 Approval Date: 04/27/17 Page 5 of 11 .9: ADHESIVE PLACEMENT DETAIL # 1 N"through plastic swtent Paddy [Bma shUht) 4wknroqulrodi} J aw -. _ X y � .-. iip� r�l •..4 Z Eaernursr, y';,' Nail through otas* oemem #when requlmo tlnr!•rlayhgzrt V �"� s' w r9 l*sue., fattens apSianal �, ._•h-•' = _ . •� 5a- l a' Save Closure Cm {cursa �<� �� � Fa" easy+§-Pl..:ie — Oheri"Lared} rr � ., P.eIdylBrn"ghd'ilwl iFstd•rlaynsr�t[ Yya �iti ~ •".�', y ,� tff in.i ~'`•.tea �"ti+ ' .�h• lattans �T .. '-• >,ea a -h . : fe'•.I�.� L^ �+ •L �v M1 y 1 11 �rtit. yp Ys'r _ EaveC;aurSt4 -'Pas r'... ^•.., - frJ� A "y, �EarWWllosOP:e MIAMFDADE COUNTY . r Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile....... . • .... ...... •••••• •• •• •••••• • •••• •••• • • •••• •••• ••••• Medium Profile / Double Raa 'ale ... ..:.. • •• •• •• •••••• 1. Starting at the eave cour:(!,tMy a minimum 2" • • (50.8 mm) x 10" (254 mm) x 1" (25.Q"foam • • •• • paddy onto the underlayient positioned as shown:.... under the pan portion of the tile closest 0 the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Obilth 9hphiticteimwnt NddyIh o i klixl•t9ayntnns �''~` �, � - ti B�ttea"saational �•� - "' ,;3 _- _'`� -" '-,•yam �,�.: €a, closure..__ mail throujph Rustic cement. #evhen rs4eiredl �t _= PaddyOftneatbtile) 3 iin. r Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm'-) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2'1Mmm) x7"(177.8mm)xl"(25.4W)fpampaddntoh''yoe underlayment positioned as.,%j"4q undef tle • ; • 0 0 0: strengthening rib closest to tlha overlock of the the being set. 000000 ...... .... . 3. Continue in same manner. lh%D?(? approxiMejy 10" • • o • • (64.5 cm2) - 12 (77.4 cm2) s qua'r8 inch adhesi% • • • • ; • contact with the underside of t�'e't le. ' • ...... • . ..... . 0. Medium Profile / Double Pan Tile '.:..' Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm'-) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nail through pUsik ea , thudw AAyment r_ 4 Aa '•. `. 1�7 elk 2in L ittrns apclaesal ff �'`•..', `4s `�- ,. _ ~�.�i �.� �� }N. r EaveC49mrst 5 Fafcia s� lY.rph� G- $' Ex ciasure High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. .••. 2. At the second course, apply mlaimum 2'• (s0.8mn j • • • • - x 7" (177.8 mm) x 1" (25.4 •mm) toam paddy onto the • * . • underlayment positioned aj sDO vp under the pan • portion of the tile closest to the pverlockRf tj a tile • • • • • • being set. •....' • • .••, ••••• • 3. Continue in same manner. "sdre approximately 17'39 * e 9 (109.7 cm2) - 19 (122.6 cr4� %ktidre inch adhesive • • contact with the underside of thetile. ; . • • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 mail diroughplastic cesnent Paddy (between tiles) 4when required► Battens optional ° Paddy(undertile) single paddy i Y on top ottrle 4xiin •'~• Single paddy on 2 x d in. b �101n~�t,` 2in. Facia —�-Gave Closure € M/Law profile Tile Nall through .plasficcement Single paddy Under tie when required) Paddy lbetween tiles) Battens Paddy [under tile► Single paddy on top ottde l� 4x4in. Single paddyon un ynxnt 214in '� 10in.��4`a 2m. • Fave Closure Eave Course fascia Medium pro8leTile 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cal of adhesive contact with tlT underside of gwAile ...... •• • • 2. Apply a 4" (101.6 mm) x VC1101.6 mm)*x V (25a. mm) foam paddy onto thederlay nl)� ct below • • the second course line Wgrled fob, paddy ..0 .. j under the strengthening"13 Wflat tile, dr.Vder t1ig. pan portion of the tile, oles" to the undgrlock for . • the second course tile tv be lAalledr Insure .... ; • approximately 8-9 in' (11.6.-55.1 cm: of adhesive •••••• contact with the undersideof the tile: . • •. • •••• (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Man through Plasticce Sanglepaddy under tile (when re4uired) Paddy ibetween tiles) Battens optional `��{ Paddy (under tilel i' � an un ert•ymen S[ ie 2x4in. pa #taeon'� tap a= Eave Course =`' �* Fascia Weephole . 14 in.3 in. Eave dosvre Drip edge High PmfllsTile MIAWDADE COUNTY l jo 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm') - 9 (58.1 cm) square JAck adhesive contact with tho underside of t4G bite at .... . • the head of the tile. Continue irosame naannar. • •ease• bees s•s• •••r• •••sae ••• • •s••• • • • •bee•• •• • • .. e • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications in contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to 1 in.from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area.. -. Underlayment (motarshown) Fascia Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. •ee• 2. Continue in same manner bringing%"pAn courses up toward the ndge.;nsure • approximately 65 (419 4*V) — 70 ( 14 cm2)• • • • : • square inch adhesive M111f with the dndersidP • of the pan tile. • • • �. . "". ' • .... .... sees• 3. Turn covers upside dgwftAjxtosing Nei'Jdersi 4•:• of the tile. Apply a mk imL" 1" (25.4rmn) x 10" (254 mm) bead of adhesive lirectl on the inner...;. edge of each side of toe cQvpr tile. eave e approximately 3/4" (19' filmy to 1" 12�-* Inm) : • • • •: from the outside edge of the tile, in*Vd, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover file to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11