RC-18-34341
-4
�i
}i3'KFGintilSdi'!IKT.TN.'d-,.1aM
2 .. ) .. ..
ub #'.s... ..,SF ... r.. ... ..
trcn3'
.. `._'iJ
3 `l3y
Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Issue Date:
Location Address Parcel Number
1292 NE 95TH ST, Miami Shores, FL 33138 1132060144040
Contacts
Permit NO.: RC-11-18-334
Permit Type:. $W11ding (Residential)
Work Ciossiffitotion: GarageEnclosure
Permit Sixtus: Approved
Expiration: 02/10/2020
MARIA DELLATORRES Owner HOME OWNER Contractor
1292 NE 95 ST, MIAMI SHORES, FL 33138 HOME OWNER
Description: GARAGE STORAGE RENOVATION Valuation: $ 5,000.00 Ins ection Reuests:3i15.762-4949
TotalSq Feet: 165.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$3.00
DBPR Fee
$2.25
DCA Fee
$2.00
Education Surcharge
$1.00
Permit Fee
$50.00
Planning and Zoning Review Fee
$35.00
Residential Application Fee
$50.00
Scanning Fee
$9.00
Structural Review ($90)
$90.00
Structural Review ($90)
$90.00
Structural Review ($90)
$90.00
Technology Fee
$3.75
Total:
$476.00
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$476.00
Credit Card
08/12/2019 $426.00
Credit Card
11/13/2018 $50.00
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are requ_{ed for ELEC_T.RiGAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AF iF A T/ I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating co,,st and zoning. Fythermore, I authorize the above named contractor to do the work stated.
Authorized Signature: Owner / Applicant / Contractor / Agent Date
August 12, 2019 Page 2 of 2
SKETCH OF BOUNDARY SURVEY trJ•!J-fz — _ tee
$ 0
, , I ,� I, , •T. •T I j''I'''I(II"'�'Ij`�'c' I e ,,. � "'1
....................... ...... ....
................ ...... ..........
' T ` rL k C.9L�l.:�LJ . -, " ,+1.�11..l. LLG' 7 p cj �•-s '�
le,A
IT
1 •T f7 11 t1 - '�
.j lO
.l
•2
W f L
tr
e
M - ti
II��
f1 e M�
I
f
�t {
F_ T
A
C i
7
�'T e R F�
5 <. v
e ,
•
p
_I
iy
l
v u
t
�rtt
e,
I i
j .l
l Ar;
1
i
Q
LOCATION MA � •� P
O WAl
NOT T SCALE
{4
1
f
11 L
1' K
r
............................................................................................ ...
.................................................................................................. ..... .......................
LEGAL DESCRIPTION:
All that part of Lots 1 and 2, in Block 85 , of 'MIAMI SHORES• - +
21.25' PARKWAY UJ
SECTION No. 3" , according to the Plat thereof as recorded in Plat - -�----°-r---�°
Rs 0 Book 10 at Page 37 of the Public Records of Miami -Dade County,
W.Md I Florida. lying West of the following described line: From a point in
5.80' 5.60' in the North line of Lotl, a distance of 75.0 feet East of the
" ''''"' '4°'` � "' ''�"'' %- Northwest corner of said Lot 1' run Southerly 100.2 feet to a point
No LD., �:..+':<:Sk;CONC'slaElyaLkr•,.•,8�.61"iC)..- .. t• '�'r=3:' at y P ..
i F.LP. 1 2 — -� Q in the South line of Lot 2, lying 82.12 feet East of the South West o
W ao
BLOCK • ' (No I.D.) l` + ` In corner of said Lot 2 and the Southeast half of the alley.„ ,�j �,�q,•�
125.Q0' CORNER
F.I.P. 112 �.•• • •eN Z •
o Z Parcel Identification Number. 11-3206-074-4040 •
' PAVERS (No I.D.) CERTIFIED TO: �.. ..a..
' I DRIIiEWAY MARIA PAOLA DE LA TORRE ���••
••••••
' 6.55' PROPERTY ADDRESS: '
I8.65' lzss' 1292 N.E. 92th Street, 49,99661•• •••••
e O Miami Shores, FI 33138 •• •• ••' ••••••
REMAINDER OF LOT • • • •
6' WO • 13.80' i F 01-M-1
_ � 23.70' 6' OD 1 SURVEYOR'S NOTES: Z•
Q�GA 74r k_ GARAGE A 0.29' BLOCK 85 • • ' • •' •' •
j L6 24.53' ELEV.=6.15' r 1) The above captioned Property was surveyed and described . . :•• •Q . J
' A/C POOL .1 based on the above Legal Description: Provided by Client.
' EQUIPMENT ^ t ;, ,� 2) All bearings and distances shown hereon are recorded andUJ •� •� w
SLA �
LOT ` �3X) ON CONC. 0 measured unless otherwise shown. 07
TWO STORY CBS �i `f. >
4 ' 3) The lands shown hereon were not abstracted for easements or O UJI
BLOCK 86' N 6.46' _ _ RESIDENCE # 1292_ _ �c M' other recorded encumbrances not shown on the plat and the w
F.F.ELEV.=8.63' (SLAB some, if any may not be shown on this section. co ILL
W
NO Z
J A 6.46' j 0 4) Foundations and/or footings that may cross beyond the co
22.98' 934'I VW boundary lines of the parcel herein described are not shown z to
G E N D (UNDERGROWND) w 00
CD
j Y a ABREVIATION SYMBOL DEFINITION 5) Elevations are based on the National Geodetic Vertical Datum 1929. ¢ _
I ' L ' '' 0 1 A/C � Air Condition a
' v 25,27' �;.� a 6) Fence ties are to be the center line of the fence. N
' _i c Calculated CI
L I t-- — REMA/NDEROFLOr C.B.S. Concrete Block Structure 7) Wall ties are t0 face of the WQII. Q p
AL / t_i L" 8.90' -L_t L 2 C.L.F. —><—x— Chain Linked Fence
LEY ' .7T _ :` is �� �zq N j 8 Ownershipsubject toopinion of the Title. w w
l3.80' 00 h p �. t• cv r BLOCK 85 � - - Center Line ) 1 I-
-L 2u I8.70' �• 1tr)E i Elev. X� Elevation 9) Underground utilities are not depicted hereon. CV O 0
POOL 6' WOOD F.F. ELEV. FINISHED FLOOR ELEVATION N
10) Zoning and Setbacks are not verified by this survey. c�
Tit p (6 =t_ m � FENCE F Found N �
�"� + � 28.15' �{ F.I.P. Found Iron Pipe 11) Benchmark :8-62, Elevation=8.65' N.G.V.D. 1929.
/13.80'' Measured
0. w
r w r , , . ., M Measured
0 0' 5.5" 5.6' 0.77' �
I 1.5'CBS WALL k I —WOHL— OVERHEAD LINE SURVEYOR'S CERTIFICATE: LU
_ P 1 WP.P q, Wood Power Pole M
�/ R/W --- Right of Way Line I hereby certify that this survey meets the minimum technical standards
°�—•�--—..—�—.� o<— ,<—,°_,. ,° _4„°_ as set forth by the Florida Board of Surveyors and Mappers in Chapter 5J-17
F.I.P. 1/2" W.Fence ��— Wood Fence Florida Administrative Code, pursuant to section 472.027, Florida Statutes. And is Z
(No I.D.) er 89.76• �C� 6' WOOD N W.P.P. W.M. o Water Meter true and correct to the best of my knowledge and belief. } �-
0 o I FENCE o ao H J m
LOT 12
NOT VALID UNLESS SEALED AND EMBOSSED WITH SUR YOR'S SEAL
LOT 11 I :n x z
(P.B. 40 - PG. 16) (P.B.40- PG. 16) Date of filed work: 05-23-2018 LL
GRAPHIC SCALE gILL
o 10 20 40 Cl)
I I I --� Adress:13801 SW 10th Terrace
Miami. FI 33184 EFRAI 0PEZ
FEET( IN T > Phone:(305) 345-9083 Professional Surveyor an Mapper # 6792 SHEET 1
i inch - 20 ft. Fax: (305) 820-3558 State of Florida. OF 1
lk
MecaWind
Std
v2.2.7.7 per ASCE 7-10
Developed by
MECA Enterprises, Inc. Copyright www.-Lecaenterprises.com
Date 2/28/2019
Project No. 19-003
Company Name Ingesol Energy Corp
Designed By Fabio Delgado
Address
Description Single House Renovation
City Weston Florida
Customer Name Paola della Torre
State Florida
Proj Location Miami Shores, Florida 33138
File Location: C:\Users\DELL\AppData\Roaming\MecaW1€�ci\,Default.wnd
••••
• •
• •
••••
••••••
Input Parameters: Directional
Procedure All Heights Building (Ch 27 Part 1) •• •
••••
•
•
Basic Wind Speed(V) =
135.00
mph ••••••
••�•
•
Structural Category =
II
Exposure Category = B •
••••••
Natural Frequency =
N/A
Flexible Structure = No••••••
•
• •
Importance Factor =
1 . 00
Kd Directional Factor = 0.85 • • • •
• • •
• • • • • •
•
Alpha =
7.00
Zg = 1200.00•ft •
• • •
•
At =
0.14
Bt = 0.84 ••••
• ••
•••••
Am =
0.25
Bm = 0.45•••••9
••••
• •
•••••
Cc =
0.30
1 = 320.00• f� •• •
• •
Epsilon =
0.33
Zmin = 30.00 ft
••••
••••••
Pitch of Roof =
0 : 12
Slope of Roof(Theta) _ .0091,9100
•
••
h: Mean Roof Ht =
11.25
ft Type of Roof = GABLED • •
•
•
RHt : Ridge Ht =
4.00
ft Eht : Eave Height = 18 .5 % ft
•
• • • 000
• • • • • •
OH: Roof Overhang at Eave=
.00
ft Overhead Type = OH w/ soff6t••
•
• •
Bldg Length Along Ridge =
32.00
ft Bldg Width Across Ridge= 24.00 Tt •
• ••
�••••:
Gust Factor Calculations
Gust Factor Careaory I Rigid
Structures - Simplified Method
Gustl: For Rigid Structures
(Nat.
Freq.>l Hz) use 0.85 = 0.85
Gust Factor Category II Riaid Structures - Complete Analysis
Zm:
0.6*Ht
= 30.00 ft
lzm:
Cc*(33/Zm)^0.167
= 0.30
Lzm:
1*(Zm/33)^Epsilon
= 309.99 ft
Q:
(1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5
= 0.93
Gust2:
0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm))
= 0.88
Gust Factor Summary
Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85
Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi
GCPi : Internal Pressure Coefficient = +/-0.18
Wind Pressurs Main Wind Force Resisting System (MWFRS) - Ref Figure 27.4-1
10
i
Z
U
' Kh: 2.01*(Ht/Zg)^(2/Alpha) = 0.57
No 760 ��, �
AV cl:zz
zz
STATE —
�i0 `:�C0R,OP'
Kht: Topographic Factor (Figure 6-4) = 1.00
Qh: .00256*(V)^2*I*Kh*Kht*Kd = 22.79 psf
Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80
Roof Area = 1204.58 ft^2
Reduction Factor based on Roof Area = 0.80
MWFRS-Wall Pressures for Wind Normal to 32 ft Wall (Normal to Ridge)
• All pressures shown are based upon STRENGTH Design, with a load Factor of 1
Wall Cp Pressure Pressure ••••••
+GCpi (psf) -GCpi (psf) i ••• •••• ••••••
----------- •• • •
Leeward Wall -0.50 13.79 -5.58 •••••• ••�• •
Side Walls -0.70 -17.66 -9.46 • ••••••
Wall Elev Kz Kzt Cp qz Press Press Total • • • • • • • • • • • • • •
• • •
•
ft psf +GCpi -GCpi + -GCpi • • • • • • • • • • • •
-----------------------------------------------------------------
Windward 18.50 0.61 1.00 0.80 24.20 12.35 20.56 26.14 •••••• •••• ••i•••
Windward 8.50 0.57 1.00 0.80 22.79 11.40 19.60 25.19 go go •go 0
• •
•••••• •
Roof - Dist from Windward Edge Cp Pressure Pressure • • • • ••
• • • • ••••••
+GCpi(psf)-GCpi(psf) ••••••
------------------------------------------------------------- --
--13.33
• • • • -
Roof: 0.0 ft to .0 ft -0.90 21.59 13 33 •••• ••••••
Roof: .0 ft to .0 ft -0.90 -21.54 -13.33 • •••• • •
Roof: .0 ft to .0 ft -0.50 -13.79 -5.58 ••••
Roof: .0 ft to 24.Oft -0.30 -9.91 -1.71
Notes - Normal to Ridge
Note (1) Wall & Roof Pressures = Qh*(G*Cp - GCPi)
Note (2) +GCpi = Positive Internal Bldg Press, -GCPi = Negative Internal Bldg Press
Note (3) Total Pressure = Leeward Press + Windward Press (For + or - GCPi)
Note (4) Ref Fig 27.4-1, Normal to Ridge (Theta<10), Theta= .0 Deg, h/1= .00
MWFRS-Wall Pressures for Wind Normal to 24 ft wall (Along Ridge)
All pressures shown are based upon STRENGTH Design, wi`,.h a load Factor of 1 \\�\0 DEL�y`q
Wall Cp Pressure Pressure \ ' I Z<-"'\GENg�.
+GCpi (psf) -GCpi (psf) : I i
--------------- --------------------------- No 76040
Leeward Wall -0.43 12.50 -4.29
Side Walls --0.70 -17.66 -9.96
STATED ���
Wall Elev Kz Kzt Cp qz Press Press Total `
ft psf +GCpi GCpi +/-GCpi // oT F ��
-------------------------------------------------------------------
Windward 4.00 0.57 1.00 0.80 22.79 11.40 19.60 23.89 G
Roof - Dist from Windward Edge Cp Pressure Pressure ///;/ N AI 1\\�0\\
+GCpi(psf)-GCpi(psf)
----------------------------------------------------------------
Roof: 0.0 ft to 5.6 ft -0.90 -21.54 -13.33
Roof: 5.6 ft to 11.3 ft -0.90 -21.54 -13.33
Roof: 11.3 ft to 22.5 ft -0.50 -13.79 -5.58
Roof: 22.5 ft to 32.0 ft -0.30 -9.91 -1.71
Notes - Along Ridge
Note (1) Ref Fig 27.4-1, Parallel to Ridge (All), h/1= .00
Wind Pressure on Components and Cladding (Ch 30 Part 1)
Roof not
shown 5
I
L � 1
1 � L
Y •
• • •
••••••
4ar
.5
....
alls
Gable Roof 8 <= 7
.. ..
..•...
Aj l c eSscre-_-own are 'I-asecl upon STFtcENG7H
Design, w_ h a _,oad ^ac-`.C- of
_ • •
Width of Pressure Coefficient Zone "a" _
- 3.00 ft
• • •
Description Width Span Area Zone
Max Min Max P Min P
psf psf
---------------------ft-----ft------------------------
New Window 5.00 6.00 30.0 4
-------------------
0.82 -0.91 27.90 -30.40
Khcc:Comp. & Clad. Table 6-3 Case 1
= 0.70
Qhcc:.00256*V^2*Khcc*Kht*Kd
= 27.78 psf
\\\\\\IIIDIIII/////
Z No 7604
STATE OF
////s�01VA I I \\\\
U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008
Fedelal Emergency Management Agency Expiration Date: November 30, 2018
National'Mboiflnsurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
Policy Number:
Maria Paola Della Torre
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number:
Box No.
1292 NE 95th Street
City State ZIP Code
Miami Shores Florida 33138
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
A part of lots 1 and 2, Block 85, of "Miami Shores Sect. No. 3" PB 10, PG 37, Miami -Dade County Folio: 11-3206-014-4040
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. 25' 51' 46.86" N Long. 800 10' 18.45" W Horizontal Datum: ❑ NAD 1927 x❑ NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 1A
A8. For a building with a crawlspace or enclosure(s):
a) Square footage of crawlspace or enclosure(s) 0 sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 0
c) Total net area of flood openings in A8.b 0 sq in
d) Engineered flood openings? ❑ Yes Z No
A9. For a building with an attached garage:
a) Square footage of attached garage 435 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 0
c) Total net area of flood openings in A9.b 0 sq in
d) Engineered flood openings? ❑ Yes x❑ No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
B2. County Name
B3. State
• Village of Miami Shores / 120652
Miami -Dade
Florida
B4. Map/Panel
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood Zone(s)
B9. Base Flood Elevation(s)
Number
Date
Effective/
(Zone AO, use Base
Revised Date
Flood Depth)
12086CO306
L
09/11/2009
09/11/2009
AE
9'
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 69:
❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source:
611. Indicate elevation datum used for BFE in Item B9: x❑ NGVD 1929 ❑ NAVD 1988 ❑ Other/Source:
812. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes x❑ No
Designation Date: ❑ CBRS ❑ OPA
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
1292 NE 95th Street
City State ZIP Code
Company NAIC Number
Miami Shores Florida 33138
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* x❑ Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO.
Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters.
Benchmark Utilized: # B-62 Elevation=8.65' Vertical Datum: N.G.V.D. 1929
Indicate elevation datum used for the elevations in items a) through h) below.
❑x NGVD 1929 ❑ NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 6.79 feet ❑ meters
b) Top of the next higher floor 8.63 ❑x feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) NSA [E feet ❑ meters
d) Attached garage (top of slab) 6 15 [E feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building 6 46 M feet ❑ meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG) 5. 9 ❑x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 6 1 Z feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including NSA. ❑X feet ❑ meters
structural support
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
/ certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? El Yes ❑ No ❑x Check here if attachments.
Certifier's Name License Number
Efrain Lopez 6792
"-A= Gin
Title
Professional Surveyor and Mapper
ce
Company Name
Efrain Lopez
S I
Her
Address
13801 SW 10th Terrace
`
000
City State ZIP Code
Miami Florida 33184
Signature Date Telephone
05/24/2018 (305) 345-9083
Copy all pages of this evat n Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
Comments (including ty a of"equipment and location, per C2(e), if applicable)
Crown of Road Elevation--' 5.69' N.G.V.D. 1929
Description ofC2.e): Two Air Conditioner located at West and East side of house top of concrete slab elevation= 6.46' N.G.V.D. 1929
Miami -Dade County Benchmark # B-62 Elevation= 8.65' N.G.V.D. 1929
Description of A5: Coordinates were obtained on site using Global Positioning System (GPS)
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
1292 NE 95th Street
City State ZIP Code
Company NAIC Number
Miami Shores Florida 33138
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item AEA. Identify all photographs with date taken; "Front View' and "Rear View"; and, if required, "Right Side View' and
"Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
1
b,
F
h
:
I
i Py
.. Photo One
Photo One Caption Front View Date Taken: 05/23/2018
r 2s
> :
�x
Photo Two
Photo Two Caption Rear View Date Taken: 05/23/2018
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6
i
i
OFKD
/12,
Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
ftiyff-en-) te
.#slue Date: 07/03/2019
Parcel Number
Permit NO.: RC-11-18-3434
Permit Type: B A ing (Residential)
Work Classification. Garage Endosu re
Permit Status: Approver!
Expiration: 03/ 16/2020
1292 NE 95TH ST, Miami Shores, FL 33138 1132060144040 j
Contacts
MARIA DELLATORRES Owner
1292 NE 95 ST, MIAMI SHORES, FL 33138
REGOSA ENGINEERING SERVICES INC Contractor
GUSTAVO VELEZ
15700 NE 2nd AVE, MIAMI, FL 331624267
Business:7862622964 CONTRACTORWORK@GMAIL.COM
Other:7863448720
Description: GARAGE STORAGE RENOVATION Valuation: $ 25,000.00 Inspection Requests:
rl��
TotalSq Feet: 165.00
Fees
Application Fee - Other
CCF
CCF (Manual)
Change of Contractor
DBPR Fee
DBPR Fee (Manual)
DCA Fee
DCA Fee (Manual)
Education Surcharge
Education Surcharge (Manual)
Permit Fee
Permit Fee
Planning and Zoning Review Fee
Residential Application Fee
Scanning Fee
Structural Review ($90)
Structural Review ($90)
Structural Review ($90)
Technology Fee
Technology Fee (Manual)
Work Without Permit 1st Offense
Work Without Permit 1st Offense
Total
Amount
$50.00
$3.00
$12.00
$110.00
$2.25
$6.00
$2.00
$9.00
$1.00
$4.00
$600.00
$50.00
$35.00
$50.00
$9.00
$90.00
$90.00
$90.00
$3.75
$15.00
$700.00
$100.00
$2,032.00
Payments
Date Paid
Amt Paid
Total Fees
$2,032.00
Credit Card
08/12/2019
$426.00
Credit Card
09/18/2019
$1,556.00
Credit Card
11/13/2018
$50.00
Amount Due:
$0.00
September 18, 2019 Page 3 of 4
Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
� 119J[
Issue Date:
Permit NO.: RC-11-18-3434
Permit Type • SulkUng {Residendb
Work ciass�}ication,,6arage Enclosure
Permit Status: Approved
Expiration: 03/16/2020
Building Department Copy
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting th' ermit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits a required TrELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWN RS I VIT: I ceify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regul tin c ii ion and zgfiing. Futhermore, I authorize the above named contractor to do the work stated.
Signature: Owner / Applicant / Contractor / Agent
Date
September 18, 2019 Page 4 of 4
J�
BUILDING
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
RECEIVED
INSPECTION LINE PHONE NUMBER: (305) 762-4949 �H
FBC 20 (: -�
Master Permit NoRo_ 19 23Y3�
PERMIT APPLICATION
Sub Permit No.
F BUILDING ❑ ELECTRIC ❑ ROOFING
SION❑ EXTENSION [:]RENEWAL❑PLUMBING
V
❑MECHANICAL ❑PUBLICWORKSNGE
OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 1292 NE 95 STREET
City: Miami Shores County:
Miami Dade Zip:
Folio/Parcel#:11-3206-014-4040
Is the Building Historically Designated: Yes NO X
Occupancy Type: Load: Construction Type:
Flood Zone: BFE: FFE:
, j (
OWNER: Name (Fee Simple Titleholder): MARIA PAOLA DELLA TORRE Phone#: 3-
Address: 1292 NE 95 STREET
City: MIAMI SHORES State: FL
Zip: 33138
Tenant/Lessee Name:
Phone#:
Email:
CONTRACTOR: Company Name: REGOSA ENGINEERING SERVICES, INC Phone#: 786-262-2964
Address: 15700 NE 2 AVE
t
City: MIAMI State: FL
Zip: 33162
Qualifier Name: GUSTAVO VELEZ
Phone#: 786-262-2964
State Certification or Registration #: CGC-1508952
Certificate of Competency #:
DESIGNER: Architect/Engineer:
Phone#:
Address:
City: State: Zip:
Value of Work for this Permit: $ 25,000.00
Square/Linear Footage of Work: 200 SF
Type of Work: ❑ Addition N Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work: GARAGE RENOVATION
Specify, color of color,.thru stile:
^.,�• , Vv
Submittal Fee $ Permit Fee $ �;Q 0' OD CCF $ I Z- 00 CO/CC $
Scanning Fee $ Radon Fee $ % t CK) DBPR $ 00 Notary $ .� `"
Technology Fee $ /r✓- cxz�) Training/Education Fee $ !-. Double Fee $ s e00
Structural Reviews $ Bond $ AV -
04'w(->'� C-5 Cj poGe 1(0. Qz TOTAL FEE NOW DUE $_
(Revised02/24/2014)_F"N �-L7, Y,.
Bonding Company's Name (if applicable)
Bonding Company's Address
City State
Mortgage Lender's Name (if applicable) _
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exce ding 2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochur will delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commenceme t mus a posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the obs nce of uch posted notice, the
inspection will not tie approved d reinspection fee will be charged.
9 !
J /:
Signatur Signature
OWNER or AGENT
The foregoing instrument was acknowledged before me this
3 d wL of AQ\ 60 ST , 20 by
q-pp,t -Pek- o is personallyknownto
me or who has producedTC—W4
identification and who did take an oath.
The foregoing instrument was ackno-C�edged before me this
21 day of AUGUST 20 19 by
GUSTAVO VELEZ o is ersonally known
me or who has produced
identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sig . Sign:
er
Print: _ Print: I ie
?o. r SIN' DIA ALVAREZ Seal:
Seal: • My CONIMISSION 4 00 238273
A•'e �a�x EXPIRES: S80tembcr 3, 2022
Bonded Thru NOery F ,i underwriters
APPROVED BY Plans Examiner
Structural Review
as
#w12fp6
Expbu: Mach 22, 2023
k0M UN ARM Not ry
*************************
Zoning
Clerk
(Revised02/24/2014)
PROPOSAL
Regosa Engineering Services. Inc
15700 NE 2 Avenue Miami Florida 33162
Commercial and Residential CFC#1427292 CCC#1327735 CGC#1508952
Office:786-361-7663 Alt:786-262-2964 Fax:305-945-4367
Submitted to: 1292 NE 95 Street, Miami Shores, A Date: 08/27/19
Attention: Maria Paola Della Torre Trade Various
Project: Home Improvements
I -SCOPE OF WORK
1.1-Regosa Engineering Services hereby proposes to furnish all materials, and
necessary equipment, and perform all labor necessary to complete the work
described below:
GARAGE RENOVATIONS
As per plans
Subtotal $9,240.00
II -CONTRACT PRICE
The above work will be completed for the sum of: $9,240.00
II -SCHEDULE OF PAYMENTS
Payments to be made by check or money order and payable to: Regosa
Engineering Services Inc. as follows: 40% upon acceptance, 30% progress
payment and 30% upon completion.
t
Maria Paola Della Torre
Homeowner
Date:
Gum
Contractor
Date: tqZ4 Za
Della Torre
08/27/2019
Page 1 of 1