FIELD DENSITY TEST 2023Location: 1190 NE 100"' Street Date: 12-06-23 Owner: Levy Residence Weather: Clear Architect: DN'A Temperature: 70' Contractor: Blanco Design+Bui€d Permit No.: r•; . Page: 1 of 1 engineerng Structural Field Report #1 OBSERVATIONS On site to review the Contractor's work. The following items were observed during the site visit: • Reviewed foundation reinforcement. Foundation reinforcement is acceptable to be epoxy doweled into existing foundations. Reinforcement is in conformance with the approved construction documents. • Reviewed masonry wall dowels. Reinforcement is in conformance with the approved construction documents. • Reviewed concrete column dowels. Reinforcement is in conformance with the approved construction documents. -End of Report- Photo(s): No COPIES TO. File REPORT BY: BCC ENGINEERING, LLC Christian Aquino, P.E., S.I., FRSE Florida License #74647 ,U ' No. 74647jr1; ChAsti� n Agyino STATE OF • i[r D' irf�fiS�� OR3p fj��'f0NA 0\0' GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES �o EC DYNATECH ENGINEERING CORP. W W W MYNATECHENGINEERING.COM MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: November 22. 2023 CLIENT: BLANCO DESIGN + BUILD. LLC. PROJECT: Proposed Addition ADDRESS: 1190 NE 100th Street, Miami Shores. FL CONTRACTOR: Blanca Design + Build, LLC. MATERIAL DESCRIPTION: Gray sand SAMPLED BY: WD TESTED BY: WD TEST RESULTS Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE 4.9 6.3 5.9 11.3 DRY DENSITY 100.1 102.6 104.1 103.6 Optimum Moisture 9.2 Percent 100% Maximum Dry Density105.8 lbs./cu.ft. % Passing 1/4" Sieve 16 % Percent 107 105 103 101 99 97 Sampled By: WD Tested By: WD Checked By: WN WD 4 6 8 10 12 14 �.� t�Q', ••......... '9 f.� Respectively submitted, Vel -. 7 I yam, •'� * No.39584 * 1ss As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization STATE OF for use, publication of statements, conclusions or extracts from or regardity� Cv Wissam Naamani, P.E. our reports is reserved pending our written approval. :���1►•'• �C 0 R I'D �w,' DYNATECH ENGINEERING CORP. S;oNA���? Florida Reg. No. 39554 ,,/I"'I+I111tlltOj1 Certificate of Authorization No.: CA 5491 D R Y D E N S I T Y GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES fo'Ee DYNATECH ENGINEERING CORP. W W W.DYNATECHENGINEERING. COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: November 22.2023 CLIENT: BLANCO DESIGN + BUILD. LLC. PROJECT: Proposed Addition ADDRESS: 1190 NE 100th Street, Miami Shores. FL CONTRACTOR:, Blanco Design + Build. LLC. Test No. 1 Location: East side of south footer Test No. 2 Location: West side of addition footer Test No. 3 Location: North side of addition footer Test No. 4 Location: East side of addition footer Test No. 5 Location: West side of addition footer Description of Material: Gray sand TEST NO. 1 2 3 4 5 DEPTH 12" 12" 12" 12" 12" FIELD DENSITY 104.2 104.6 103.9 104.4 104.0 MOISTURE CONTENT % 7.1 7.4 6.8 7.2 6.6 MAX. DENSITY IN THE FIELD % 98.5 98.9 98.2 98.7 98.3 COMPACTION REQUIREMENTS % OF MAXIMUM 98% 98% 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 105.8 105.8 105.8 105.8 105.8 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS * Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the tested compaction layer prior to construction. .1,1j111t1111I���11���, SAAD Nq.4�•',r, Respectfully submitted, * ; No. 39584 * = Vissam Naamani, P.E. * -97YNATECH ENGINEERING CORP. .p STATE OF Florida Reg. No. 39584 '• �, �- Certificate of Authorization No.: CA 5491 Tested By: WD �'�rD��' • Q R tp.`�� Checked By: WN NAI-�-���� 'ell 1illnitll''� *A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination. A soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. 2