DENSITY REPORT 2023PAN ;Fr CONSULTANTS Client Mr. Julio M. Miranda Miran Construction LLC Davie, FL Soil Density Testing Report Project Proposed Addition 290 NE 103rd St Miami Shores, FL Date 5/22/2023 Tested Proctor Dry Density Moisture Compaction(pcf) Test No. Test Location Soil Description (pcf) (%) (%) L. Gray to Tan 1 WITHIN GARAGE AREA, SW 102.9 101 10.7% 98/0 ° SAND 2 WITHIN GORGE AREA, NE L. Grayto Tan 102.9 97.3 11.3% 95% Paul C. Catledge, P.E. 68448 SOLUTIONS AND SERVICE PAN -gin CONSULTANTS Modified Proctor (ASTM D-1557) Report Client Project Miran Construction Proposed Addition Attn: Mr. Julio Miranda 290 NE 103rd St 750 Greenbriar Ave. Miami Shores, FL Davie, Florida 33325 DATE TESTED 3/31/2023 SOIL DESCRIPTION Tan SAND TEST NO. 1 2 3 4 5 6 DRY DENSITY (PCF) 100.0 100.9 101.7 102.6 102.9 100.5 MOISTURE (%) 3.9 6.3 8.5 10.6 13 15.4 ^y104.0 U a;103.0 L02.0 V) w101.0 0 >-100.0 99.0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 MOISTURE CONTENT MAXIMUM DRY DENSITY 102.9 OPTIMUM MOISTURE (%) 12.3% �9 STATE F - W� Paul C. Catledge, P.E. 68448