DENSITY REPORT 2023PAN ;Fr
CONSULTANTS
Client
Mr. Julio M. Miranda
Miran Construction LLC
Davie, FL
Soil Density Testing Report
Project
Proposed Addition
290 NE 103rd St
Miami Shores, FL
Date
5/22/2023
Tested
Proctor
Dry Density
Moisture
Compaction(pcf)
Test No.
Test Location
Soil Description
(pcf)
(%)
(%)
L. Gray to Tan
1
WITHIN GARAGE AREA, SW
102.9
101
10.7%
98/0 °
SAND
2
WITHIN GORGE AREA, NE
L. Grayto Tan
102.9
97.3
11.3%
95%
Paul C. Catledge, P.E. 68448
SOLUTIONS AND SERVICE
PAN -gin
CONSULTANTS
Modified Proctor (ASTM D-1557) Report
Client Project
Miran Construction Proposed Addition
Attn: Mr. Julio Miranda 290 NE 103rd St
750 Greenbriar Ave. Miami Shores, FL
Davie, Florida 33325
DATE TESTED
3/31/2023
SOIL DESCRIPTION
Tan SAND
TEST NO.
1
2
3
4
5
6
DRY DENSITY (PCF)
100.0
100.9
101.7
102.6
102.9
100.5
MOISTURE (%)
3.9
6.3
8.5
10.6
13
15.4
^y104.0
U
a;103.0
L02.0
V)
w101.0
0
>-100.0
99.0
2 3
4 5 6 7 8 9 10 11 12
13 14 15 16 17
MOISTURE CONTENT
MAXIMUM DRY DENSITY 102.9
OPTIMUM MOISTURE (%) 12.3%
�9 STATE F - W�
Paul C. Catledge, P.E. 68448