Loading...
RF-18-3448 (2)Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Issue Date:11/28/2018 Parcel Number 321 NE 93 ST, Miami Shores, FL 33138 1132060136240 Contacts Permit NO.: RF-11-18-3448 Permit Type: Roof Work Classification: Tile Permit Status: Approved Expiration: 05/27/2019 ELIZABETH COWEN Owner ELIZABETH COWEN Applicant 321 NE 93 ST, MIAMI SHORES, FL 33138 321 NE 93 ST, MIAMI SHORES, FL 33138 Other:3054580120 Other:3054580120 ESTRADA ROOFING Contractor DANIEL N GONZALEZ-LAUZAN Business: 7863853137 info@estradaroofing.biz Description: INSTALL NEW ROOF TILE TO NEW ADDITION Valuation: $ 11,375.00 Inspection Requests: MATCH EXISTING TILE 305-762-4949 Total Scl Feet: 232.00 =j Fees Amount Application Fee - Other $50.00 CCF $7.20 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $2.40 Roofing Fee $200.00 Scanning Fee $12.00 Technology Fee $6.25 Total: $284.10 Building Department Copy Payments Date Paid Amt Paid Total Fees $284.10 Check# 7345 11/15/2018 $50.00 Credit Card 11/28/2018 $234.10 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS A FIDVT: I certify at all a regoing information is accurate and that all work will be done in compliance with all applicable laws regulating c nstruction arDy g. F ore, I authorize the above named contractor to do the work stated. Signature: Owndrr/ / Applicant / Contractor / Agent Date November 28, 2018 Page 2 of 2 J ' 4 Miami Shores Village Building Department 4BY v 15 2018 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 it(T4 Q 6- INSPECTION LINE PHONE NUMBER: (305) 762-4949 60 FBC 26 C-� - BUILDING Master Permit No. RC-4-18-1107 PERMIT APPLICATION Sub Permit No.-_RFI G - 3LH8 ❑BUILDING ❑ ELECTRIC Q ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 321 NE 93 ST City: Miami Shores County: Miami Dade zip: 33138 Folio/Parcel#: 11-3206-013-6240 Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder) Address: 321 NE 93 ST City: MIAMI SHORES Tenant/Lessee Name: Email: ELIZABETH COWEN State: FL Zip: 33138 Phone#: CONTRACTOR: Company Name: ESTRADA ROOFING Phone#: (786)385-3137 Address: 1738 SW 57 AVE City: MIAMI State: FL Zip: 33155 Qualifier Name: DANIEL GONZALEZ-LAUZAN Phone#: 305-668-8800 State Certification or Registration M CCC1328913 Certificate of Competency M DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ I 1 3p Square/Linear Footage of Work: Z 3 Z Type of Work: ❑ Addition ❑ Alter ' ' n 0 New ❑ Repair/Replace ❑Demolition Description of work: INSTALL NEW OF TILE TO NEW ADDITION "MATCH EXISTING TILE Specify color of color thru tile: C.,4 Submittal Fee $9 Permit Fee $ , Scanning Fee $ Radon Fee $ _ �_.9 4.014— C Y2 u^.- - Technology Fee $ Training/Education Fee $ Structural Reviews $ _ CCF $_ DBPR $ CO/CC $ Notary $ _ Double Fee $ Bond $'y-p— ( 9 - l toy . TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. /1-1 Signature �'L) Signature NER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this -\� �� day of n\_ AD-W 20 \q2> , by 6a ZASe7' / wh s personally known me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: _ Print: L54hyl f AaiG Seal: ******************** APPROVED BY _ (Revised02/24/2014) ,p0 NNotary PJUIiC S1a1e of Florida Anaiiyn Estrada +� My Commission GG 173156 Expires 01/10/2022 The foregoing instrument was acknowledged before me this day of V(12Z ,20IR by ��n ��� 7G11QQ`uwh"o is s a nown as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign as Vint: Seal. *00&+r�, Notary Public State of Florida Anailyn Estrada +� My Commission GG 173156 o,�� Expires0l/10/2022 ******************* * ** * * ************** Plans Examiner Zoning Structural Review Clerk r Y Villa 900 STANDARD COLORS Marmalade 1 MPCS6493 In Stock in Lake Wales and Pompano CRRC ID: 0942-0020 / Ref:.25 / Emit:.90 / SRI: 25 Spanish Blend Co!or Coat* 1MPSS6789 In Stock in Lake Wales and Pompano CRRC ID: 0942-0043 / Ref .32 / Emit:.89 / SRI: 34 Mandarin Sun 1 MPCS6254 Made to Order in Lake Wales and Pompano In Stock in Lake Wales and Pompano---_-----, CRRC ID: 0942-0097 / Ref:.26 /Emitmit: 91 /SRI: 27 Gold Dust 1MPCS7165 In Stock in Lake Wales and Pompano Casa Grande Blend 1MPCS6144 In Stock in Lake Wales and Pompano CRRC ID: 0942-0014 / Ref:.23 / Emit:.91 / SRI: 23 Arizona Clay 1 MPCS7049 In Stock in Lake Wales and Pompano Burnt Mission 1MPCS7117 Made to Order in Lake Wales and Pompano Mission Red Flash Color Coat' 1 MPSS7445 Made to Order in Lake Wales and Pompano The printed colors shown in this brochure may vary from actual available the colors. 29 Color Coat products are available in Florida region only. Always use actual product samples for color selection. t I ROOF ASSEMBLIES AND ROOFTOP STRUCTURES r x " '— Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) —� — � l l� Permit No. RC-4-18-1107 Process No. 1LF ,B Contractor's Name ESTRADA ROOFING ,lob Address 321 NE 93 ST ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ■ Mortar/Adhesive Set Tiles ...... ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood 4ingr :0 • OlShak� • • • • • • .. ❑ Prescriptive BUR-RAS 150 ...... ; "• • • • • ROOF TYPE .... ...... ■ New roof ❑ Repair ❑ Maintenance ❑ Reroofing ',,,F Reciverw4j. ROOF SYSTEM INFORMATION • • • • • • ' Low Slope Roof Area (SF) 0 Steep Sloped Roof AREA (SSF) 232 Total*(SFf 232 • • • • • Section B (Roof Plan) :....: Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow draft jmVelde dimen- • sions of sections and levels, dearly identify dimensions of elevated pressure zones and location of parapets. Onty New Addition part o (j W Q y c c a � J W :D W C� Q Cr > _ 0 ~ G } U) W Z Q C - n a W w > © i — 0 C7 C - Y r, FLORIDA BUILDING CODE — BUILDING, 6th EDITION (2 17) 03 �� 469 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: BORAL ROOFING, LLC Notice of Acceptance Number: 18-050916 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: - 39.1 P1: - 68.1 P1: - 100.7 MEDIUM PADDY FOAM AH-160 ADHESIVE SYSTEM Deck T I Type: 5/8" PLYWOOD: •0.'� •1••�• 900000 • • Y • • • • Type Underlayment: 30# ASTM D226 TtPE•II FELT • Roof Slope: • •-•-• - •-- -• :' • • • • 3 12 --:::- - - • •.••• Insulation: N/A ••: 69900 •••. 1• • so 0 0000*0 ••.••• • Fire Barrier: N/A • : • • ...... Ridge Ventilation? Fastener Type & Spacing: 1.25 RS NA LS 6" LAFS12: FIELt3 • N/A \- - " '- Adhesive Type: SELF ADHERED \ �Type cap sheet:[ 'OLYSTI K— T _PLU S Mean Roof Height: 15 Roof Covering: VILLA DBL ROLL Type & Size Drip [3"X3"26GA GALV. 1 Edge: NAILED @ 4- O.C. FLORIDA BUILDING CODE — BUILDING, 6th EDITION (2017) 471 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (Pi: 39.1 x k .315=12.32) - Mg: 7.62 = Mr, 4.70 Product Approval Mf 45.5 (P2: 68.1 xX .315 = 21.45) - Mg: 7.62 = M2 13.83 Product Approval M, 45.5 (P3:100.7 xk .315 = 31.72) - Mg: 7.62 = M, 24.10 Product Approval Mf 45.5 Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf • •.:. Mr required Moment Resistance* • • • Mean Roof Height Roof Slope 15' 20' 25' 30' • • ;4R 212 34.4 36.5 38.2 39.7 • 2 3:12 32.2 34.4 36.0 37.4 • 0 0%948 -a 4:12 30.4 32.2 33.8 35.1 • . 5:12 28.4 30.1 31.6 32.8 ; • 0;31.9 6:12 26.4 28.0 29.4 30.5 3:2.4 ; 7:12 24.4 25.9 27.1 28.2 , • 31.0 *Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of fZuies and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1: x L = x w: = ) - W: x cos 0 = Fr, Product Approval F' (P2: x L = x w: = _ ) - W: x cos 0 = F2 Product Approval F' (P3: x L = x w: = ) - W: x cos 0 = Fri Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 472 FLORIDA BUILDING CODE - BUILDING, 6th EDITION (2017) MIMIAMEE � MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails toperform in t ieeceepted ...... manner, the manufacturer will incur the expense of such testing and the AHJ may immediately rejoke, modify, or • suspend the use of such product or material within their jurisdiction. RER reserves the righlig revoke t0N*9(!c'eptanq4..:. if it is determined by Miami -Dade County Product Control Section that this product or materia9foils to meet the • requirements of the applicable building code. • This product is approved as described herein, and has been designed to comply with the Florldg Building Code ...... . ... ..... including the High Velocity Hurricane Zone of the Florida Building Code. • .. .. .. . ...... DESCRIPTION: Boral Villa 900 Concrete Roof Tile ' . . . . ...... .... % LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo pity, state apd•fpfipwing statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.] 6-0711.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Boral Roofing Villa 900 Length = 17" TAS 112 Width = 13" Type 1 b '/2" thick Class III Trim Pieces I = varies TAS 112 w = varies varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BOND' Roof Tile Adhesive "Tile Tite" Roof Tile Mortar DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive Product Description Two component polyurethane foam adhesive. Product Description :...:. 0000*0 Low profile, interlocicrng1 hegh pressure extruded • • concrete roof tile equfPPed With three nail holes • • • • and double rolls. Fo?dir 1f deck, batten, mortar...: or adhesive set applioli �onst • • • • • • • • • Accessory trim, concret;"f piejes for use ar • • • • ridges, hips and rakes. '• •' ...... . . . . ...... Single component polyurethane foam roof tile adhesive. Premixed, pre -bagged roof tile mortar. Two component polyurethane foam adhesive. 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Bermuda Roof Co. Inc. The Dow Chemical Company NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 2 of 7 2.3 EVIDENCE SUBMITTED Test Aaency Test Identifier Test Name/Report Date Nutting Engineers 13343.1 TAS 112 Apr. 2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied 94-060B Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) Redland Technologies P0631-01 Wind Tunnel Testing 0 Auly'1994 ...... TAS 108 (Mortar Set} • • Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testin : : • .: • to.... • Aug. 1994 , • • • •, TAS 108 (Nail -On) .... . . ...... The Center for Applied Project No. 307025 Wind Driven Rain "" • 0 ' Oct. 1994 • Engineering, Inc. Test #MDC-76 •: TAS 100 • • .. .. .. . ...... The Center for Applied 25-7183-1 Static Uplift Testing • •; •; Feb. 1995 •, Engineering, Inc. 25-7183-2 TAS 102 (2 Quik-Drive Screws, Direct Deck) :....: The Center for Applied 25-7214-2 Static Uplift Testing 1;aro4 1995 Engineering, Inc. 25-7214-6 TAS 102 (1 Quik-Drive Screw, Direct Deck) (1 Quik-Drive Screw, Battens) Celotex Corporation 528454-2-1 Static Uplift Testing Sep. 1998 Testing Services 520109-2 TAS 101 Dec. 1998 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Evaluation Calculations Aerodynamic Multipliers 09/01/16 Walker Engineering, Inc. Evaluation Calculations Two Patty Adhesive Set System April 1999 Walker Engineering, Inc. Evaluation Calculations Restoring Moment Due to Gravity 09/01/16 American Test Lab of South RT0617.02-16 TAS 112 06/29/16 Florida NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 3 of 7 2.3 EVIDENCE SUBMITTED Test Asency Test Identifier Test Name/Report Date PRI Construction Materials COPO-002-02-11 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) PRI Construction Materials COPO-002-02-04 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) PRI Construction Materials COPO-002-02-03 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) 3. L.IMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set the applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. • • • • • • 3.4 Minimum underlayment shall be in compliance with the applicable Roofing AgNigtjons $nr►dnrds lisj jq:: • section 4.1 herein. • • . • • • • 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to thVfdof sloglw:ws stated ' .... ... otherwise by the underlayment material manufacturers published literature. . .• ...... . ... ...•*.. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall •be in compliance with • : - applicable building code. '. . . . . ...... 4. INSTALLATION • 4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length-1 (ft) Width-w (ft) Villa 900 Concrete Tile 10.90 1.42 1.08 Table 2: Aerodynamic Multipliers - 1 (ft3) Tile Profile % (ft3) Batten Application (ft3) Direq UeCK Appi cation Villa 900 Concrete Tile 0.291 0.315 Table 3: Restoring Moments due to Gravity - M9 (ft.-lbf.) Tile Profile 2":12" 3":12" 4":12" 6":12" 691:12" 7":12" or greater Villa 900 Concrete Tile Direct Deck Direct Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.70 [J.6U6.56 7.50 6.42 7.34 6.26 7.15 1 6.08 6.95 NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" plywood) (min. 19/32" plywood) Villa 900 2-10d Ring Shank Nails 27.8 37.4 28.8 Concrete Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Clip) 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail Eave Clip) • 2-10d Smooth or Screw 35.5 35.5 : .'. 34.8 ... Shank Nails (Field Clip) • • • • • • 2 10d Smooth or Screw 31.9 31.9 • 32.2 Shank Nails Eave Clip) .... :" Table 5: Attachment Resistance Expressed as a Moment Mf•(ftabf) • • • • • • • for Two Paddy Adhesive' Set Systems 00. 0 Tile Tile Application Win; um Attaohmeni` • • Profile ; .. jesistance % Villa 900 Concrete Tile The Dow Chemical Company TileBond " ' 26.12.0. ' ICP Adhesives Polyset® AH-160 two- 26. component foam DAP Foam Touch N Seal StormBond ® 2 Roof 55 4 Tile Adhesive two -component foam 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBond one -component foam, minimum weight per paddy 11.4 grams. 3 ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams. 4 DAP Foam Touch N Seal StormBond ®2 Roof Tile Adhesive, average weight per paddy 8 grams, two component foam. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Villa 900 Concrete Tile ICP Adhesives Polyset® AH-160 two -component foam 86.615 ICP Adhesives Polyset® AH-160 two -component foam 45.5 s DAP Foam Touch N Seal StormBond ®2 Roof Tile Adhesive DAP Foam Touch N Seal StormBond ® 2 Roof Tile 708 Adhesive NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 5 of 7 5 Large paddy placement of minimum 54 grams. 6 Medium paddy placement of minimum 24 grams. 7 Medium paddy placement of minimum 30 grams. 8 Large paddy placement of minimum 60 glams. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Villa 900 Concrete Tile Mortar Seth 20.60 Tile-Tite Roof Tile Mortar. 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo ai'>y 41ed be",... or following statement: "Miami -Dade County Product Control Approved". • • •..• . • • • • . •..... .• •• .. • ... . •. • ••.••• • • • • • • •••••• •.••.• LABEL FOR BORAL VILLA 900 CONCRETE TILE 0 . o • : •. •. i •• • .• . • . THE OF TILE (LOCATED ON UNDERSIDE 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0509.16 MIAMMADECOUNMW Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 6 of 7 Mail holes 1" PROFILE DRAWING VILLA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 18-0509.16 Expiration Date: 09/21/21 Approval Date: 06/28/18 Page 7 of 7 MIAMbQADE ;; MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in tbg v4pted manner, the manufacturer will incur the expense of such testing and the AHJ may immediatelx re yoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the rigbj jq rp;oke t6isWMptan%• 0; • if it is determined by Miami -Dade County Product Control Section that this product or materjaMls to meet the . requirements of the applicable building code. • • • • • This product is approved as described herein, and has been designed to comply with the Flodda Building Code • •; • • • including the High Velocity Hurricane Zone of the Florida Building Code. ": .. .. .. . ...... DESCRIPTION: Polyglass Polystick Underlayments • . . . . ...... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state anbfdlowin�. statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. • • • RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy SemfnoJ NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1 of 8 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick IR-Xe 65' x 3'33/8" ASTM D 1970 A fine granular/sand top surface self -adhering, APP Manufacturing Or 65' x 3' polymer modified, fiberglass reinforced, bituminous Location #1 & #2 60 mils thick sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. Polystick Dual Pro 61' x 3'33/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a Location #2 metal roofing and roof tile underlayment.- • • : « Polystick Tile Pro 61' x 3'33/8" 09966 TAS 103 and A rubberized asphalt self-ad4Q4il;,*.glass -�iber4polyester .' Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing mexibme. Desigriedas a me" •:. Location #2 roofing and roof tile under]ajimrit! • Polystick TU Max 658" x 3'3-3/8" TAS 103 and A rubberized asphalt self-adil ip'polyecfec rei'nforced... Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Des" as a. •raaf4 ile «• • • • Location # 1 & #2 underlayment. of es• • pose** Polystick TU P 32' 10" x 3'33/s" TAS 103 and A rubberized asphalt waterproofing memo a �� jglass-• « • • : • Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced, wVh a. granular surface ; • • «• Location #2 designed for use as a tile roof UhdellaymQnV.'. ' .• . Polystick TU Plus 65' x 3'33/8" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester (Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location # I & #2 Polystick MTS 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastoflex S6 G 32'10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/1.7 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL Test Azency Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. LABELING: EVIDENCE SUBMITTED Test Identifier Test Name/Report P 10870.09.08-R 1 P 10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390.08.12-2 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC 10130.06.16-3 PLYG-10130.06.16-1 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 JX20H7A RX 14E8A DX23D8B DX23D8A TAS 103 TAS 103/ASTM D4798 & G155 ASTM D 1970 TAS 103 ASTM D 1623 TAS 103/ASTM D4798 & G 15 5 TAS 110/ASTM D4798 & D 1970 ASTM D 1623 ASTM 136164 TAS 103, TAS 110 & ASTM D1623 ASTM D 1623 TAS 103 & TAS I tO • • • ASTM D 1970 & TAS I TO ' TAS 103 & TAS 1 iQ':" ASTM D1970 & TAS C": TAS 103 TAS 103 •••••• TAS 103/ASTM D4798 �G.1SS TAS 103/ASTM D4798 f G155 TAS 103/ASTM D4798 W6156 TAS 103/ASTM D4798 & G 15 5 Date 12/04/08 04/ 13/09 07/01 /10 03/02/ 11 04/26/11 09/01 /11 10/19/11 08/07/12 07/02/13 05/12/14 1 W03/14 • 10/07/14•••••• :.. LQ/j 7/ 14 0, 06/27/16 """ 6f/27/16:••••� ••.••• ' 09/29/06 •:•;IA0/07•••••• Q7/06/09 • • " Abl/08;..... •••1i/.09/09: "02/18/10 TAS 103/ASTM D4798 & G 15 5 02/18/10 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MIAMNDADE COUNTY NOA No.: 17-0614.22 � Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a Pninianum 4 Ileo lap. (for..: • 000000 • base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied .... . 0 0:0 0 Surfacing: See General Limitations Below. • • • • • • . ... 00000 .. .. .. . ...... Deck Type 1: . . . . ...... Wood, non -insulated ••.... Deck Description: Min. 19/32" plywood or wood plank • • • • . System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self'alhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. NOA No.: 17-0614.22 MIAMMADECouNrr Expiration Date: 09/13/21 Approval Date: 07/06/1.7 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape sl6all be pressed in place and formed around the protrusion to ensure a tight fit. A second lacer of.Polystick'Nall be ...... applied over the underlayment. • • • ...... . ...... GENERAL LIMITATIONS: ; • • • • 1. Fire classification is not part of this acceptance. "" ... • • 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and PoL�stick MTS,$1'uc*may be •.: used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, rrf t ilsystems and quarry . . . . .....0 slate roofassemblies. : • •, 0 • Polystick TU P may be used in all the previous assemblies listed except metal roofirig..'. ;....; Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof file siAems.00 Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Ex osure Limitations (Days MTS IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 M1AMMAD' COUNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 Rule 61G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3) Profile MTS S6 G TU P, Tile Pro, TU Max MTS Plus MTS Plus with Dual Pro TU Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12 without battens 0 • Profiled Prohibited 4..12 6.12 6..12 4.12 ••�►2 Tile without battens 10. . The above slope limitations can be exceeded only by using battens in accordance with 414 Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When batter *&p requtr;g�, #}fey shal • be utilized during loading and installation of tiles. "" • ' • • • ...... . ... ..... Care should be taken during the loading procedure to keep foot traffic to a minimum aaaxo avoid'droKpO1ng of..... tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for to;dkV Procedure •- two tiles • • laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for A total hf„4 ties — for • • • • all underlayments except Polystick MTS which shall be loaded onto battens. d n 0 rn N t rt^i E I V POL1rST1CKlU Plus NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. •••••• 1. Polyglass does accept the direct application of Polystick underlayment membranes to400 decks Installers de cautioned to refer to applicable local building codes prior to direct deck installation tq ppjy�e this Ts ff4aptable. Please also refer to applicable Product Data Sheets of the corresponding products. ...:.. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as lLr.P.4l,glass' • Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimu�►):: v metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other r iplis, at a tyi�irr* m rate*::: of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail aiaAarea para ctavar" on . • the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cove#, the area being •: • •••••. back -nailed. (Please refer to applicable local building codes prior to installation.) ; 9 0 0 0 •• • .. . • . 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. •. • 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of TV12" or greater. It is suggested that on pitch/slopes in excess of 6 t/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE ...... . ...... .... . ..... ...... .... ..... .... .. . ...... . . . . ...... NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8 MIAM .t MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidadexoWeconomv ICP Adhesives and Sealants, Inc. 12505 NW 44`h Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida i"k&rng Code • • • including the High Velocity Hurricane Zone of the Florida Building Code. • • ...... . ...... DESCRIPTION: ICP Adhesives Polyset® AH-160 • • • • ...... .... . ..... LABELING: Each unit shall bear a permanent label with the manufacturer's name or losv,oeitZ, state and.fiollow�14..' statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein' • • • • • • •.... RENEWAL of this NOA shall be considered after a renewal application has been filed and there has beev7W change••• in the applicable building code negatively affecting the performance of this product. • • • 0 :0 .. . •• . •.... •• • TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. vow NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/1.7 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive Polyset®AH-160 ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment • •... 30 & 100 ...... . ...... PRODUCTS MANUFACTURED BY OTHERS: •. :...:. " • • .... . •..•• Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current N00ovAich list attar..hmer4.;.. • 00.0 resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. 000000 • .. •... •••... • MANUFACTURING LOCATION: . . • . . ; • • • • • ..... 1. Tomball, TX. .. . •• . . . • • • PHYSICAL PROPERTIES: Proper Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ftz Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ 400 F., 2 weeks +6.0% Volume Change @I58°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MIAMI•DADE COUNTY Expiration Date: 05/10/22 AIS Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier Test Name/Revort Date #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 NB-589-631 ASTM D 1623 02/01/94 9637-92 ASTM E 108 04/30/93 01-6743-011 ASTM E 108 11 /l 6/94 01-6739-062b[ l ] ASTM E 84 01 / 16/95 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 • 528454-2-1 TAS 101 • • • L1Y23L�18 ' 528454-9-1 ••.... 528454-10-1 ...• •••••. 520109-1 TAS 101 ' • •..' jMS;98 • , 520109-2 •••••• . ..• • • • • ..;..' 520109-3 •• •• •• .•.... 520109-6 ""' ` • 520109-7 •••••• 520191-1 TAS 101 • • s 63/02/99 ..... 520109-2-1 • so LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 maybe used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minu4i after ICP Adhesives ...... Polyset AH-160 has been dispensed. • • • • • • 9. ICP Adhesives Polyset® AH-160 and minimum weight shall be in acc'OTAI& with the placement patty 'Placement Details' herein. Each generic tile profile requires the specific placement notes rein. :...;. • .... . ..... .. .. .. . ...... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles 43 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams ugder pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable masking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control orpproved' or tPeVami-• • • • ...... Da e County Product ControlSea ass own below. • • . • ... • . MIAlMInOME COUNTY • • • • • • . .' ��u ... �. r� . . • . •••..• . . BUILDING PERMIT REQUIREMENTS: •' • • •....• • As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMMADECOUNTY NOA No.: 17-0322.03 Expiration Date: 05/10/22 322.03 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 =1 tttYthrotrglplastictswowd hddyl6+noathTli•} feWl►fodj t)nd•IlaylMnt '� i e 101n �- •tom'`.. etthr+s,vtf,,,a! fawC"r% 10in. Fasda 2 ht Ewe Uesun Nall through plastic cement (when required) Nddy (Reneeth TOO th+d.rlaym.nt ;� 10 in.x ti i 2Nf.nrlda �,� . �atterss optional ��'- Bare ela.ure faro coupe"� `� `— Fasda NA thfough PleNic (When ro4=1 ►addy I1110ne•thTilel Vnderl.ytit•nt . \y 2 In. •ride S.ittons %�opUenal • ►" EareCourse Fascia weephok 10 in. 1". £are dosure Drlp odq* MIAMI-DADE COUNTY ...• r F1atlLow Profile Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 rgm) Y, 1" (25i4 rr>;r foam . • • . • paddy onto the underla�uvht positioned §s shown . • under the pan portion of alas the closet{ td the . • . e : • overlock of the tile being sat• 0 .••.• • • 2. Continue in same mann&-rtlsure approximately 99; • • (I 09.7 cm2) — 23 (148.4 cin2 'equarc. incV4dhesiSc '' contact with the undersU � of the tile. 000'' . . • . • . . • • • • • . •••••• . ••••.• •• • .• • • • • • • 00 • High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 =�hrwyh akc•m►nt Paddy l6mwhTB•) IwMc+regdred) tlnd•claynant • "``.! 1 tiatt•�ueptfenal • EawCoun• • 101n J{ rasda I la E.veCiotun Nail throu0h plattic cement !when rcauiredl Paddy jB•n•athTile) undrrlryin.nt { 71n 222 fattens Optional 10�. UveCwn. Eerie [bcuee - . F•16• MIAMI-DADE COUNTY ...t t Flat/Low Profile Tile I. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cmz) — 23 (148.4 cmz) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cmz) - 12(77.4 cmz) square inch adhesive contact with the underside of the tile. . . • . ..... . Medium Profile / Double Pad?U 1. Starting at the eave course, .app1TY a mimmt9m*2" (56.8• 00 mm) x 10" (254 mm) x 1 ".W.4 rnm) fogrrl p;ddy ..... • onto the underlayment positibne$ as shfowd under tbq.... pan portion of the tile closest►to the overlook of the .' tile being set. Insure approximately 1711 Q2;7 cmz) • • • • • 23 (148.4 cmz) square inc4 adrlssive contact with tlu • • underside of the tile. ' 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cmz) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nad through ptailk co (Aen "Trod) ►.ddy IlMrwthTlb) Ur++..tyrsxnt 1 ' _ �''iIm smttrts opdonal . Em �� ascia Wrrphoir loin. �2N. Emc/osare Orip adgo High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm') - 19 (122.6 cm2) square inch adhesive contact with the undersideof tile. • • • • • • ...... . ...... .... . ..... r o o r o 0 0 :0: .... . .. .. 000 o r orroor . o . . . . .or.r. oor roo o 0600 00 0 00 0 0 o r NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 MU � Pa plastic cement ddy(betweentiles) sattensoptimal ' • Paddy (under tile) \ � singlpettle epaddy antodtile singleWdy `r 2 x ! 101n 2 in. Fave c loswe Rattt.ow Procne Tne Hail t)xough plastic cement Single paddy under the (when required) Paddy (between tiles) BPaddy (under tile) optimal ontopol sirmfie pad 9 P�ix a ln. :a addyon rlaynuerut o 21n. Eave Closure Eave Course Fascia Medlurn ProflleTlle 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1 " (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the the for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cm') of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x I " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed: •kUi;e approximately 8-9 in (5 j,6,;F.1 cm`2) of adhesive • • contact with the underside. 4f the tilP.• • •' • • • • • : • •••••• (Instructions continued on next page) • • • • • ...... . ... ..... •• •• •• • •••••• • • • • • •••••• •• • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Hail through plastic Single paddy under Me twiny+ required) paddy (between tiles) Bmerts paddy (under tne) optional { j l pad �oaunderfa �' 4Y 4 in. �e 2 s 4 topaddyon `,+1 top of tik ti EaveCourse `• asda Weephole loin. 2 in. Ewe dosure Drip edge High Profile T)1e 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cmz) - 11 (71cmz) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm') square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • Y •••••• • • • • • • • • • • • • • • •••• • ••••• • •••••• • ••• ••••• • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 1► Place enough adhesive to achieve 65 to 70 In contact with the pan tile. 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to- 25 sq. In. contact area.. .�3< IUnderlayment Eave closure imotar shown) Fascia ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Steep pitch applications (when required) Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directs-boshe inner edge of each side of g.A r tile �Leave • approximately 3/4" (1 j Il gi) to I "6. 91.4'tnm) .... from the outside edgc6 of:" tile, inward, free c1f foam to allow for expansion. aaaaaa a •aaaaa aaaa 4. Turn cover tile over MO'ftm is gppol!o and 00000 place onto pan tile coUrse.0insure a'i1'lini?num d?";' 20 (129 cm2) - 25 (14f.I Vr;2) squa re inch '. contact area on each side of the cc�ttle to thg* pan tile. Continue in Salt rtanner..Tripi away; a a • e; any cured exposed foam adhesive' Polaeing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/.10/22 Approval Date: 04/27/17 Page 11 of 11