Loading...
RC-11-21-3106 Uplift Test 935 NE 99 StLank Engineering LLC. Testing & Engineering Services Certificate of Authorization#33264 Tel: 954-245.8976; Fax: 954.301.7776 1000 E Atlantic Blvd. #119 Pompano Beach, FL 33060 Attention: Client: Dakoma Roofing Test Date: 03/02/2023 Roof Tile Uplift Test Report Village of Miami Shores Building Department Permit # RC-11-21-3106 Property Address: th 935 NE 99 Street ,Miami Shores, Florida Roof Pitch: _ Type of Tile: Roof Area: 6 in 12 i Roof Tile per NOA 46.00 squares Tile Attachment Method: Foam Adhesive per NOA Field Instrument: IMADA Force Gauge 0-100 Serial number: 467066 Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: 20.00 sq. 20 As per FBC 2020 Passed Field Area: 26.00 sq. 26 As per FBC 2020 Passed No. of Corner: 12 12 As per FBC 2020 Passed Ridge Areas: 230 pcs 23 As per FBC 2020 Passed Important: These laboratory results can change due to future weather impacts and /or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. All tested locations were done using an Imada Force Gauge instrument with a minimum uplift load of 35lbs (for mortar or adhesive set tiles) and for mechanically attached tiles a minimum static test uplift load of 80% of the Resistance Moment (Mr') or 80% of the Resistance Load (Y) as listed in Product Approval (NOA) was applied. Please see attached a Roof Sketch for this project. Cordially, Lank Engineering LLC. (NOA 21-1122.01) Andre Bigatao, PE Fla. Reg. No: 80977 i