Loading...
RF-09-22-2337 Uplift Test 1202 NE 93 StLank Engineering LLC. Testing & Engineering Services C:954-245-8976 0: 754-307-3391 1000 E Atlantic Blvd, #119 Pompano Beach, Florida, 33060 Attention: Test Date: 03/29/2023 Property Address: Roof Pitch: 3in12 Tile Attachment Method: Roof Tile Uplift Test Report City of Miami Shores, Building Department. Permit # RF-09-22-2337 1202 NE 93rd Street, Miami Shores Type of Tile: Roof Tile per NOA Foam Adhesive per NOA. Roof Area: 34.90 sci. Field Instrument: IMADA Force Gauge 0-100 Serial number: 243454 Contractor: Axtion Roofing Contractors Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: 14.9 sq. 15 As per FBC 2020 Passed Field Area: 20.0 sq, 20 As per FBC 2020 Passed No. of Corner: 6 6 As per FBC 2020 Passed Ridge Areas: 180 pcs. 18 As per FBC 2020 Passed Important: These laboratory results can change due to future weather impacts and /or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. All tested locations were done using an Imada Force Gauge instrument with a minimum uplift load of 35lbs (for mortar or adhesive set tiles) and If applicable, for mechanically attached tiles a minimum static test uplift load of 80% of the Resistance Moment (Mr') or 80% of the Resistance Load (f) as listed in Product Approval (NOA) was applied. Please see attached a Roof Sketch for this project Cordially, Lank Engineering LLC. (NOA 21-1122.01) Andre Bigatao, PE Fla. Reg. No: 80977 MAR 2 7 2023 C WIN II 1 II i i II I I j 1