Loading...
RF-10-22-2556 Uplift Test 311 NE 103 StJanuary 31, 2023 To: Miami Shores Village Building Department 10050 NE 2nd Avenue Miami Shores, FL 33138 Engineering & Testing Co. 745 Shotgun Road, Fort Lauderdale, FL 33326 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net Roof Tile Uplift Test Report Test Date: January 31, 2023 Permit #: RF-10-22-2556 Address: Sigala Residence 311 NE 103rd Street, Miami Shores, FL Contractor: Paul Ban e Roofing Roof Pitch: 3:12 Attachment method: Pol Pro AH 160 Tile Type: Ea le Capistrano Device Used: "IMADA DPS 110" Force Gauge Serial # 425458 Total Sloped Roof Area: 34.00 squares All Testing is in strict accordance with the Florida Building Code, 2020 Edition, High Velocity Hurricane Zone — Testing Application Standard (TAS) 106. Roof Area: 34.00 squares Total Number of Tests Number of tests Passed % Passed Field Area 1): 16.00 squares 9 T36-T44 9 100% Perimeter Area 2 : 18.00 squares 26 T10-T35 26 100% No. of Corner Areas 3 : 9 9 T1-T9 9 100% —Ridge/Hip Areas:262 pcs 14 T45-T57 14 100% Based upon the field tests, I certify that 100% of the static up -lift tests "PASSED" the testing criteria of 35.0 lbf load, and meets the attachment resistance for adhesive Set Systems, as specified in the NOA. Should you have any questions regarding the above, or if require additional information, please do not hesitate to contact this office. Sincerely, CeBB gineerii �T tieoHU2� (NO A 8 ) G RV r �� 1/311 3 0830) RCI Registration C I, 100 For The Firm Cc: Paul Bange Roofing Enc. Location Sketch Calibration Certificate 1 ■ i• a Engineering & Testing Co. 745 Shotgun Road, Fort Lauderdale, FL 33326 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net HANDLIFT RESULTS: Passed the protocol criteria of less than 3% loose. We performed the up -lift test T — Tested tiles and Passed; Total Area: 34.00 squares No. of tested Tiles: F — Tested tiles and Failed; - Field Area (1): 16.00 squares - Field Area: 9 M — Missing Tiles; - Perimeter Area (2): 18.00 squares - Perimeter Area: 26 B — Broken Tiles; - No. of Corner area (3): 9 - Corner areas: 9 -Ridge/hip areas: 262 pcs - Ridge/Hip areas: 14 31 Legend: 36-44 Field tests 10-35 Perimeter tests 1-9 Corner tests 45-57 Ridge Tests TAS 106 TESTS LOCATION SKETCH Permit # RF-10-22-2556 Sigala Residence 311 NE 103`d Street, Miatni Shores, FL Engineering & Testing Co. 745 Shotgun Road, Fort Lauderdale, FL 33326 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net TEST RESULTS (P = PASSED, F = FAILED) Test Location Uplift Pull Test (P or F) Test Uplift Location Pull Test (P or F) Test Location Uplift Test Pull Location Test (P or F Uplift Pull Test (P or Test Location Uplift Pull Test (P or F 1 P 26 P 51 P 2 P 27 P 52 P 3 P 28 P 53 P 4 P 29 P 54 P 5 P 30 P 55 P 6 P 31 P 56 P 7 P 32 P 57 P 8 P 33 P 9 P 34 P 10 P 35 P 11 P 36 P 12 P 37 P 13 P 38 P 14 P 39 P 15 P 40 P 16 P 41 P 17 P 42 P 18 P 43 P 19 P 44 P 20 P 45 P 21 P 46 P 22 P 47 P 23 P 48 P 24 P 49 P 25 P 50 P Engineering & Testing Co. 745 Shotgun Road, Fort Lauderdale, FL 33326 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net QC Metallurgical, Inc. Testing & Consulting Services CEBB Corporation P.O. No.Verbal Imada-Digital Force Gauge Range 0-100 Lbs. Serial No. 425458 Standard In Lbs. 0 10 20 40 60 80 100 -10 -20 -40 -60 -80 -100 Accuracy f 1 % @ Indicated Scale Instrument Reads in Lbs. 0.0 9.9 19.9 39.9 59.8 79.8 99.7 -9.9 -19.9 -39.9 -59.9 -79.8 -99.7 Scale is within f 1 Lb., no adjustments were made. April 11, 2022 QCM Job No. 22DM-197 Calibrated with Salm Slotted Weights. S/N QCM-425, 71 pieces. Runge Varies. Accuracy at Varies. N.I.S. r. 4 KELC334393. Date 08/12/2017 - Due: 08/31/2022. Calibrated I.A.W. ANSI/NCSI. 7540-t Environmental Conditions:701+/-3°F. The accuracy and calibration of this instrument are traceable to the National Institute of Standards & Technology and are guaranteed to meet publish d sp1e/cinf)atinfts. Date Calibrated 4/11/2022 '� "J "" Date Due 4/11/2023 Jemy i ciofano V Q. C. Metallurgical, Inc. 2870 Stirling; Road * I lollywood, PI. 33020-1 199 * (954) 889-0089 * Fax (954) 362-5742 F-mail: f'gratc@gcmct.com