DS-12-22-3145 Engineer Ltr 920 NE 95 St.DS,11-Zz-31its SOUTH FLORIDA S.G. & E. ENGINEERING STRUCTURAL, GEOTECHNICAL & ENVIRONMENTAL ENGINEERING Testing Laboratory Certificate Number 04-0329.02 8060 West 23'd Avenue Suite #7 Hialeah Florida 33016 Telephone: (305) 826-3855. Fax: (305) 826-8545 E Mail: soflaengineering @ yahoo. corn Field Density Test of Compacted Soils Client I Date: 03/16/2023 Address 920 NE 95 Street, Miami Shores Florida33138 Order# 023-00106 Project Driveway Pad Contractor Permit# Description Building Slab / fine sand lime rock Location Test #1, NE Side Lab# D-00119 Location Test #2, NEC side Lab# D-00120 Location Test #3, CC side Lab# D-00121 Location Test #4, SEC side Lab# D-00122 Location I Test # 5, SE Side Lab# D-00123 Location Lab# Location Lab# Test Results of Field Densities ASTM method: D-2922-81 Description of Test Area I Density Test Ddveway: 920 NE 95 Street, Miami Shores Florida33138 Lab No. D-00119 D-00120 D-00121 D-00122 D-00123 Test No. 19 20 21 22 23 Depth in inches 12" 12" 12" 12" 12" Field Density (lbs/Cft.) 112.1 112.1 112.0 112.0 112.1 Moisture Contents % 10.3 8.7 9.3 9.6 11.1 Maximum Density % in the field 98.1 98.1 98.0 98.0 98.1 Reg. Compaction by jobspecs 98% 98% 98% 98% 98% 100% Max. Density (Proctor) 114.3 114.3 114.3 114.3 114.3 Proctor No. P-216 P-216 P-216 P-216 P-216 Optimum Moisture % 8.9 Remarks 1 I) All the above tests comply with the jobs citications. Checked B J.C. I Report By I W.M. Respec ully Submitted By, South Florid �Engineering IIbJr� -- Arshad Viqar, P.E Florida Registration Number:38863 Seal: SOUTH FLORIDA S.G. & ENGINEERING STRUCTURAL, GEOTECHNICAL & ENVIRONMENTAL ENGINEERING Testing Laboratory Certificate Number 04-0329.02 8060 West 23'd Avenue Suite #7 Hialeah Florida 33016 Telephone: (305) 826-3855. Fax: (305) 826-8545 E Mail:soflaengineering@yahoo.com PROCTOR COMPACTION TEST DATE: 03/16/2023 CLIENT: PROJECT: Drivewav Pad ADDRESS: 920 NE 95 Street. Miami Shares Florida33138 SAMLPED BY: J.T. TESTED BY: _J.Ch.__ TEST RESULTS Sample Number_ 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and 18" drop AASHTO designation T-180-C. % MOISTURE DRY DENSITY lb/soft 5.6 108.5 8.9 114.3 11.3 108.7 116 114 Optimum Moisture 8.9 Percent 100% Maximum Dry Density 114.3 lbs./cu.ft. 112 110 108 % MOISTURE 4 6 8 10 12 14 16 18 Respectfully,�ubmitted By, South Florida S. ,, &E.Enginecring Arshad VigM, RE Florida Registration Number.38863 SEAL: D R Y D E N S I T Y