RF-01-23-109 Inspection Report 1202 NE 93 StA+ Engineering Testing Lab. LLC
Lab Certificate # 21-0308.01 CA Lic. No. 33337
7066 SW 44 St Miami, FL 33155 Ph: (305) 668-5792 Fax: (786) 513-3754
A PLUS E1iIiEEEIii Email: Aplusetl@yahoo.com
iESEiii Eli
INSPECTION REPORT
Date : Monday, February 20, 2023;
City: Village of Miami Shores
Building Department
10050 NE 2nd Avenue
Miami Shores FL 33138
Contractor : JOHNSON GROUP
RE: Flood Test or Integrity Test (ASTM 5957)
Job Site: 1202 NE 93 ST, Miami FI, 33138
Dear Building Inspector:
Our office has conducted a test to evaluate whether the waterproofing system is leak -free under
hydrostatic pressure base on the Florida Building Code 1519.16.6 and in accordance with ASTM 5957. All
deck drains were temporarily closet, the surface flooded to a maximum of 3 inch at the high point and
water was retained for a minimum of 24 hours. An inspections was then conducted on the area beneath
the roof deck to check for any leak.
The Flood test commenced at 5:00 PM, FEBRUARY 15, 2023 and was complete at 12:10 PM,
FEBRUARY 17, 2023 for over period of 24 hours on a concrete deck.
The water proofing system used is Vulkem 350NF-SU350NF Waterproofing System with NOA: 17-
0406.02
The maximum depth observed during the test was two inches and was locate at the highest point of deck.
At the time of inspection and after following the above procedure no water leak was evident from
underneath the membrane.
This report is not to be construed as a warranty of the roof, only representation of the actual conditions at
time of inspection in the areas inspected.