Loading...
RC-01-22-228 Engineer Ltr 145 NE 98 StG3'OTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES G} DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM Miami, October 17, 2022 Mr. Orlando Iglesias ORONI CONSTRUCTION 14040 NW 6th Court North Miami, FL 33168 Re: Proposed Addition @ 145 NE 98th Street tee _ Miami Shores, FL Dear Mr. Iglesias: Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on October 17, 2022 at the above referenced project. DEC was authorized to perform a compaction test only. The purpose of our test was to determine the degree of compaction of the tested layer of material only. In no way shall a compaction test replace a demucking inspection, soil bearing capacity determination, or a pad certification. A soil boring test must be performed by client if not yet done, prior to construction to verify subsoil conditions. Underlying soils below test levels must be verified to prevent future settlements. (DEC) was not authorized to perform supervision and certification of the building pad preparation. This is not a pad certification. Our reports must be provided to all involved parties for their approval. Topsoil and organics have not yet been removed from the slab areas and must be removed prior to slab construction. Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on other areas or dates. Any subsequent site disturbances due to water erosion, rain, storm gutters discharging at footings, construction activities, excavations, overgrown, vegetation, traffic and other disturbances will void this test and the site must be re - compacted and re -tested prior to construction. Environmental analysis tf the soil materials is not part of the scope of services. If environmental analysis of the soils is required, we can provide a proposal for performing an environmental analysis of the soil materials. No other analysis is implied or warranted. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Enclosed find copies of the compaction test results. look forward to do so in the near future. Sincerely vouz ' 93 Wissam N'aamari, P. E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 Certificate of Authorization No.: CA 5491 It has been a pleasure working with you and �t►►►si i 111r►rr►► * No.39584 STATE OF '.r- I GF.OTECHNICAL 1 ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS 1 ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES ■ _ (; DYNATECH ENGINEERING CORP. W W W.DYNATECH ENG INEERING.COM MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: October 17, 2422 CLIENT: ORONI INC. PROJECT: Proposed Addition nae ADDRESS: 145 NE 98'' Street. Miami Shores. FL CONTRACTOR: Oroni, Inc. MATERIAL DESCRIPTION: Gray sand SAMPLED BY: WD TESTED BY: WD TEST RESULTS Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE 4.9 5.8 7.1 11.9 DRY DENSITY 100.1 102.9 105.2 104.8 Optimum Moisture J Percent 100% Maximum Dry Density 106.8 lbs./cu.ft. % Passing V Sieve 96 Percent Sampled By: WD Tested By: WD Checked By: 'AN 108 106 104 102 100 98 10 12 14 16 ►■►ttistitrtrrrr Respeclively submitted, As a mutual are submitted as theleontden[ al p operty of n to clients, the public cl cnts Sand authorization elves, all p*��rts ' SAA D f�''�''i�� _ .S for use, publication oFstatcments, conclusions or extracts from or regardip �* �]� ••�� E NS' '4 r''.� Wissarn Na •'Rani, P.E. �••'•• 9 DYNATECH ENGINEERING CORP. our reports is reserved pending our written approval. •,• y * r No. 39584 ; * Florida Reg. No. 39584 - * =Certificate of Authorization No.: CA 5491 .4 STATE OF ��`''�SS�OIVALENk5'`$ D R Y D E N S I T Y 2 GEOTECHNICAI_ I ENVIRONMENTAL I Mf\TERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES c DYNATECH ENGINEERING CORP. W W W.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: October 17.2022 CLIENT: ORONL INC. PROJECT: Proposed Addition (a� ADDRESS: 145 NE 98th Street. Miami Shores. FL CONTRACTOR: Oroni, Inc. Test No. 1 Location: North side of addition footer Test No. 2 Location: East side of addition footer Test No. 3 Location: West side of addition footer Test No. Location: Test No. Location: Description of Material: Gray sand TEST NO. 1 2 3 DEPTH 12" 12" 12" FIELD DENSITY 104.9 105.6 105.4 MOISTURE CONTENT % 6.8 7.4 7.2 MAX. DENSITY IN THE FIELD % 98.2 98.9 98.7 COMPACTION REQUIREMENTS % OF MAXIMU 98% 98% 98% 100% MAXIMU DENSITY (LAB) 106.8 106.8 06.8 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS * Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the tested compaction layer prior to construction. ►►►►►t I +++�►�► .�`'`►��I+SAQ� !vqRespectfully submitted Tested By: WD -z �•2 ` Checked By: N = * : No. 39584 W: * ^�■��^� Sg LM * — Wissam Naamani, P.E. STATE OF DYNATECH ENGINEERING CORP. '• ' �= Florida Reg. No. 39584 •:. L 4 R VD p'•'� �.`� Certificate of Authorization No.: CA 5491 '►►nrr r n u t ►+►►►■► *A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination. A soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval.