GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING .SBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES
Ec, DYNATECH ENGINEERING CORP.
WWW.E)Yk4ATECHEkJGIr4EERIr4G.COM
Miami, October 17, 2022
Mr. Orlando Iglesias
ORONI CONSTRUCTION
14040 NW 6th Court
North Miami, FL 33168
Re: Proposed Addition @
145 NE 981h Street
Miami Shores, FL
Dear Mr. Iglesias:
QC - - C-) � - '-'-2 - 22'��'
Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on
October 17, 2022 at the above referenced project. DEC was authorized to perform a compaction
test only. The purpose of our test was to determine the degree of compaction of the tested layer
of material only. In no way shall a compaction test replace a demucking inspection, soil bearing
capacity determination, or a pad certification. A soil boring test must be performed by client if
not yet done, prior to construction to verify subsoil conditions. Underlying soils below test levels
must be verified to prevent future settlements. (DEC) was not authorized to perform supervision
and certification of the building pad preparation. This is not a pad certification. Our reports must
be provided to all involved parties for their approval.
Topsoil and organics have not yet been removed from the slab areas and must be removed
prior to slab construction.
Our findings are relative to the date and areas of our site work and should not be relied upon to
represent conditions on other areas or dates. Any subsequent site disturbances due to water
erosion, rain, storm gutters discharging at footings, construction activities, excavations,
overgrown, vegetation, traffic and other disturbances will void this test and the site must be re -
compacted and re -tested prior to construction.
Environmental analysis of the soil materials is not part of tie scope of services. If environmental
analysis of the soils is required, we can provide a proposal for performing an environmental
analysis of the soil materials. No other analysis is implied or warranted.
As a mutual protection to clients, the public and ourselves, all reports are submitted as the
confidential property of clients, and authorization for use, publication of statements, conclusions
or extracts from or regarding our reports is reserved pending our written approval.
Enclosed find copies of the compaction test results
look forward to do so in the near future.
Sincerely your s
4 �t4,-
Wissam Naamani, P. E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Special Inspector No. 757
Certificate of Authorization No.: CA 5491
It has been a pleasure working with you and
`,�,,•P�, 5AA D N4�•,,,��
* ; No. 39584
.p STATE 4F r�
j�rA4 '�G
GEOTRCHNICAL I ENV7R014MErj-rj L I MATERIALS TESTING I ASBESTOS 1 ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES
_ EG DYNATECH ENGINEERING CORP.
W W.DYNATECHENGINEERING_COM W
MOISTURE -DENSITY RELATIONS OF SOILS
PROCTOR COMPACTION TEST
DATE: October 17. 2022
CLIENT: ORONI. INC.
PROJECT: Proposed Addition nas
ADDRESS: 145 NE 98h Street, Miami Shores, FL
CONTRACTOR: Omni Inc.
MATERIAL DESCRIPTION: Gray sand
SAMPLED BY: WD TESTED BY: WD
TEST RESULTS
Sample Number 1
The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a
10 lb. Hammer and an 18" drop ASTM D-1557.
% MOISTURE
4.9
5.8
7.1
11.9
DRY DENSITY
100.1
102.9
105.2
104.8
Opiimum Moisture 9.2 Percent
100% Maximum Dry Density 106.8 lbs./cu.ft.
% Passing 1/4" Sieve 96 Percent
Sampled By: WD
Tested By: WD
Checked By: WN
108
106
f 104
1 102
100
98
10 12 14 16
��t�tt� Respectively submitted,
As a ic and ourselves, all reports
are submitted as he al confidential propertyn Ic clients, the of clients, and authorization \���,L,, SA A D N ,y'��ifF •T
for use, publication of statements, conclusions or extracts from or regard�r �-�G]P jG•E iflS�;•.;���'�•� Wissam Na ani, P.E.
our reports is reserved pending our written approval. _ y '•.y DYNA_TECH ENGINEERING CORP.
* ; No. 39584 ; * Florida Reg. No. 39584
* =Certificate of Authorization No.: CA 5491
STATE OF
"/"'/ S NALE
��'�►+rtrtitrttt'��
D
R
Y
D
E
N
S
I
T
Y
Pj
GEOTHCHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES
( _DEC DYNATECH ENGINEERING CORP.
W W W.DYNATECHENGINEERING_COM
FIELD DENSITY TEST OF COMPACTED SOILS
DATE: October 17, 2022
CLIENT: ORONI INC.
PROJECT: Proposed Addition (a�
ADDRESS: 145 NE 98 h Street, Miami Shores, FL
CONTRACTOR: OroniT_Inc.
Test No. 1 Location: North side of addition footer
Test No. 2 Location: East side of addition footer
Test No. 3 Location: West side of addition footer
Test No. Location:
Test No. Location:
Description of Material: Gray sand
TEST NO.
1
2
3
DEPTH
12"
12"
12"
FIELD DENSITY
104.9
105.6
105.4
MOISTURE CONTENT %
6.8
7.4
7.2
MAX. DENSITY IN THE FIELD %
98.2
98.9
98.7
COMPACTION REQUIREMENTS
% OF MAXIMUM
98%
98%
98%
100% MAXIMUM DENSITY (LAB)
106.8
106.8
106.8
REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS
* Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the tested compaction layer prior
to construction. �tkjjj+Illr►+►+►►
�,AD Ngq,,l Respectfully, submitted,
_. �S `jC•E NSA, •.,'�.'�'
Tested By: WD • • No. 39584 * W ' I,� j,�n
Checked By: WN - _--._
* = Wissam Naamani, P.E.
.p STATE OF ; •Z DYNATECII ENGINEERING CORP.
Florida Reg. No. 39584
.�` • .Z 0 R 1 ��.�` Certificate of Authorization No.: CA 5491
......
►f►+r11IIIIIW
*A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination.
A soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all
reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is
reserved pending on our written approval.
GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES - D!'=I .-_ING SERVICES
6 01" P,
0_DPEq DYNATECHx-J". ANEFRIN
Miami, December 15, 2022
Mr. Orlando Iglesias
ORONI CONTRUCTION
14040 NW 6 Court
North Miami, FL 33168
Re: Proposed Addition
145 NE 98 Street
Miami Shores, FL
Dear Mr.: Iglesias
Pursuant to your request, Dynatech Engineering Corp. (D13C) performed a Compa.c _ic, r 'Pest on
December 15, 2022 at the above referenced project. DEC was authorized 'o )erform a
compaction test only. The purpose of our test was to determine the degree of comps ion of the
tested layer of material only. In no way shall a compaction test replace a demucki a ; r spection,
soil bearing capacity determination, or a pad certification. A soil boring test must be )erformed
by client if not yet done, prior to construction to verify subsoil conditions. Ur,dc .' ring soils
below test levels must be verified to prevent fixture settlements. (DEC) was not at-1 iorized to
perform supervision and certification of the building pad preparation. This s : [ot a pad
certification. Our reports must be provided to all involved parties for their approval
Our findings are relative to the date and areas of our site work and should not be •e`e d upon to
represent conditions on other areas or dates. Any subsequent site disturbances d7 .c to water
erosion, rain, storm gutters discharging at footings, construction activities, cx --avations,
overgrown, vegetation, traffic and other disturbances will void this test and the si� e 1 east be rc-
compacted and re -tested prior to construction.
Environmental analysis of the soil materials is not part of the scope of services. If t.,. J -onenental
analysis of the soils is required, we can provide a proposal for performing an c;n- -j -onmental
analysis of the soil materials. No other analysis is implied or warranted.
As a mutual protection to clients, the public and ourselves, all reports are sub'm t ed as the
confidential property of clients, and authorization for use, publication of statement-;, t;c,nclusions
or extracts from or regarding our reports is reserved pending our written approval.
Enclosed find copies of the compaction test results. It has been a pleasure working v i1 you and
look forward to do so in the near future.
Sincerely yours,
S laJt
assam aamani, P. E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Special Inspector No. 757
Certificate of Authorization No.: CA 5491
GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICE& rill .'r ING SERVICES
..__DEC DYNATECH E`' SEE I '" R
MOISTURE -DENSITY RE+ LA71ONS OF SOILS
PROCTOR COMMA CT] ON 'VEST
DATE: December 15 2022
CLIENT: ORONI CONSTRUCTION
PROJECT: Proposed Addition
ADDRESS: 145 NE 98 Street Miami Shores. FL
CONTRACTOR: ORONI CONSTRUCTION
MATERIAL DESCRIPTION: Tan sand
SAMPLED BY: WD TESTED 1 (: WD
TEST RESULTS
Sample Number 2
The following compaction test was conducted in accordance with the Standard Methods for Moisture Densit.:, F-e ations of soil using a
10 lb. Hammer and an 18" drop ASTM D-1557.
% MOISTURE DRY DENSITY
5.0
100.2
6.1
103.8
7.4
105.1 108
11.0
104.9
106
104
Optimum Moisture 9.0 Percent
100% Maximum Dry Density 106.4 lbs./cuff 102
% Passing V Sieve 96% Percent
100
Sampled By: WD
Tested By: WD
98
Checked By: WN 01►►►srtIIrlfl"/► 4 6 8 0 12 14
SNAD
��. ..........
j.s - ,f Respectively subm,tte 1,
As a mutual protection to clients, tie public and ourselves, all reports �� �' �••�• 'S� �' / ..ti
are submitted as the confidential property of clients, and authorization
for use, publication of statements, conclusions or extracts from or regar&g _JVissam Nadiani... _.
our reports is reserved pending our written approval. — ` �YNATECH ENG IN ;ZING CORP.
,.Q
• STA E Ql :•� lorida Re-. No. 31 5. I
•=��Z, Certificate of Auth,>ri; a i m No.: CA 5491
A.
R
Y
D
E
N
S
I
T
Y
2
GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I rNSPECTION SEE -VICES O: '.r .--JNG SERVICES
Q -RING C(
FIELD DENSITY TEST OF COMPACTED SOULS
DATE: December 15 2022
CLIENT: ORONI CONSTRUCTION
PROJECT: Pro osed Addition
ADDRESS: 145 NE 98 Street Miami Shores, FL
CONTRACTOR: ORONI CONSTRUCTION
Test No. 4 Location: East side of addition underslab
Test No. 5 Location: Center of addition underslab
Test No. 6 Location: West side of addition underslab
Test No. Location:
Test No. Location:
Description of Material: Tan sand
TEST NO.
4
5
6
DEPTH
12"
12"
12"
FIELD DENSITY
105.2
105.8
105.4
MOISTURE CONTENT %
7.1
7.7
7.2
MAX. DENSITY IN THE FIELD %
98.9
99.4
99.1
COMPACTION REQUIREMENTS
% OF MAXIMUM
98%
98%
98%
100% MAXIMUM DENSITY (LAB)
106.4
106.4
106.4
_
REMARKS: ALL ABOVE TEST RESULTS
COMPLY WITH COMPACTTON
RFClT IIR
1 7NTS
* Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the to :te ' c,mpaction layer prior
to construction. 'vtt�15 tt l l t r+Rr r rr��r�r
A,+,f rfrrrr Respectfully siilh-c�.1'cd,
Tested By: WD
Checked By: WN No. 3938-6-
_ �; 'rWissan3 i�iatrlani, .�:
=DYN,vrECH %NGiNj ;;'ZING CORP_
.p STAir OF .: ; Florida Rcg. No. Y -5 1
` Certificate ofAuthi'ri, a inn No.: CA 5491
*A density test determines the degree of compaction of the tested layer of material only. In no wa, shall a density test replace a soil bea, ing c ricity determination.
A soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clien s, plc public and ourselves, all
reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts f on-, c - regarding our reports is
reserved pending on our written approval.