RC-02-21-305 1240 NE 97 StGEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES EC DYNATECH ENGINEERING CORP. LVWW.DYNATSCHENGINEERING.COM Miami, June 22, 2022 Mr. Claudio Fernandez, GC CF CONSTRUCTION & REMODELING, INC. 3532 SW 113`h Court Miami, FL 33165 Re: Proposed Rear Terrace @ 1240 NE 97`h Avenue Miami Shores, FL Dear Mr. Fernandez: Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on June 22, 2022 at the above referenced project. DEC was authorized to perform a compaction test only. The purpose of our test was to determine the degree of compaction of the tested layer of material only. In no way shall a compaction test replace a demucking inspection, soil bearing capacity determination, or a pad certification. A soil boring test must be performed by client if not yet done, prior to construction to verify subsoil conditions. Underlying soils below test levels must be verified to prevent future settlements. (DEC) was not authorized to perform supervision and certification of the building pad preparation. This is not a pad certification. Our reports must be provided to all involved parties for their approval. Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on other areas or dates. Any subsequent site disturbances due to water erosion, rain, storm gutters discharging at footings, construction activities, excavations, overgrown, vegetation, traffic and other disturbances will void this test and the site must be re - compacted and re -tested prior to construction. Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is required, we can provide a proposal for performing an environmental analysis of the soil materials. No other analysis is implied or warranted. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Enclosed find copies of the compaction test results. It has been a pleasure working with you and look forward to do so in the near future. Sincerely yours, Wissam aamani, P. E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 Certificate of Authorization No.: CA 5491 * . N0.39584 .p STATE OF al,'filll11111W% GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES E� DYNATECH ENGINEERING CORP. W W W. DYNATECHENGINEERING.COM MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: June 22 2022 CLIENT: CF CONSTRUCTION AND REMODELING. INC. PROJECT: Proposed Rear Terrace 0. ADDRESS: 1240 NE 97" Street Miami Shores. FL CONTRACTOR: CF Construction and Remodeling, Inc. MATERIAL DESCRIPTION: Tan coarse sand SAMPLED BY: WD TESTED BY: WD TEST RESULTS Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE 4.3 5.9 7.5 11.8 DRY DENSITY 103.3 106.3 108.2 107.7 Optimum Moisture 9.2 Percent 100% Maximum Dry Density109.8 lbs./cu.ft. % Passing 'W'Sieve 94 Percent III 109 107 105 103 101 Sampled By: WD Tested By: WD Checked By: WN 1111+tt1 l t 11111lrr►r� 4 6 8 ! 0 12 14 CIC-D' •��'E NS •. ,4'r..■ Res ectively submitted.f E•-'-. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization = * : NO. 39584 for use, publication of statements, conclusions or extracts from or regarding '_ ITissam Naamani, P.E. our reports is reserved pending our written approval = 'k]YNATECH ENGINEERING CORP. STATE aF �lorida. Reg. No. 39584 = ��J ; 1 Certificate of Authorization No.: CA 5491 \ti rrrrl11111111111+1 GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRt3.LING SERVICES EC DYNATECH ENGINEERING CORP. I WWW.DYNATECHENGINEERING.COM im, / FIELD DENSITY TEST OF COMPACTED SOILS DATE: June 22.2022 CLIENT: CF CONSTRUCTION AND REMODELING. INC. PROJECT: Proposed Rear Terrace Q. _ ADDRESS: 1240 NE 97`h Street, Miami Shores. FL CONTRACTOR: CF Construction and Remodeling. Inc. Test No. 1 Location: East side of rear terrace underslab Test No. 2 Location: Center of rear terrace underslab Test No. 3 Location: West side of rear terrace underslab Test No. Location: Test No. Location: Description of Material: Tan coarse sand TEST NO. 1 2 3 DEPTH 12" 12" 12" FIELD DENSITY 108.6 108.4 108.2 MOISTURE CONTENT % 7.4 7.4 7.0 MAX. DENSITY IN THE FIELD % 98.9 98.7 98.5 COMPACTION REQUIREMENTS % OF MAXIMUM 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 109.8 109.8 109.8 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREM EN-I5 * Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the tested compaction layer prior to construction. %%1tlun1111"1,#f `�,�.•p� SAAD�r,Respectfully submitted, Tested By: WD ` i.:•. Checked By: WN = it ; No. 395$4 _Wissam aamani, P.E. EFDYNATECH ENGINEERING CORP. ,p STATE OF .: C Florida Reg. No. 39584 '.�0.�`�5�,� 0 RlD,�:`.;� Certificate of Authorization No.: CA 5491 r , '•;,,,S/ONA`� '11111111111101 'A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination. A soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the coulhlcEUEul property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written Eipprov.ii