Loading...
RC-11-21-2844 334 NE 102 ST (1)f�C- 0-2-1-2Egq TASK LABORATORIES, INC. 14241 SW 140 Street, Miami, Florida 33186 Phone: (305) 235-5355 Fax: (305) 235-8353 Field Density Test of Compacted Soils ASTM Method: D - 2922-81 Client RHR of Miami Inc. Order # T2022-072 Address 4281 SW 139u Ave, Miramar, Florida 33027 Date 7/13/2022 Project Single Family Residence Gauge # 34393 Address 334 NE 102" Street, Miami Shores, Florida PO # Test ff LIFT ff Locations 20 Final Subgrade of of slab on grade at center area of great room 21 Final Subgrade of of slab on grade at center area of study 22 Final Subgrade of of slab on grade at center area of dinning roome Description of Material 3) Light tan fine sand Backfill =Embankment Subbase X Basecourse Subgrade I X I Grade Building Pad Laboratory Identification Number T2022-072 T2022-072 T2022-072 Test Number 20 21 22 ept in inches 12 12 12 Field Density. Lb/Cu.Ft (Wet Basis) 114.3 115.0 114.4 Field Density. Lb/Cu.Ft (Dry Basis) 104.3 104.6 103.9 Moisture Contents 9.6 9.9 10.1 Maximum Density in the Field (%) 99.0% 99.2% 98.6% Compaction Requirement by specs % of maximum density 98% 98% 98% 100% Maximum Density (lab) 105.4 105.4 105.4 Proctor T-180 AASHTO Method C 3/3177 3/3177 3/3177 Compaction Test Result PASS PASS PASS~� • - }` Optimum Moisture 11.2 Remarks OX Tested By E.V/M.I Checked By MI FLORIDA CERTIFICATE OF AUTHORIZATION No.EB 7944 Respectfully Aamir A. Ghori, P.E. # \G 55538; ATE OF Should any subsoil conditions in the property (area) tested found different from that encountered on the tested locations reported on our Density Test, TASK LABORATORIES, INC. is not responsible. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential Dropery or cuents ana Tor pomicwons or statements or extract Trom regarding is reservec penning ourwntten approval. SOIL & MATERIAL TESTING GEOTECHNICAL RXPLORATIONS CIA/QC INSPECTIONS ENVIRONMENTAL AUDITS TASK LABORATORIES, INC. 14241 SW 140 Street, Miami, Florida 33186 Phone: (305) 235-5355 Field Density Test of Compacted Soils ASTM Method: D - 2922-81 Fax: (305) 235-8353 Client RHR of Miami Inc. Order # T2022-072 Address 4281 SW 139"'Ave, Miramar, Florida 33027 Date 7/13/2022 Project Single Family Residence Gauge # 34393 Address 334 NE 102" Street, Miami Shores, Florida PO # Test ff LIFT if Locations 17 Final Subgrade of of slab on grade at center area of master bedroom 18 Final Subgrade of of slab on grade at center area of kitchen 19 Final Subgrade of of slab on grade at center area of garage 3escription of Material 3) Light tan fine sand 3ackfill Embankment Subbase X Basecourse 5ubgrade X Grade Building Pad Laboratory Identification Number T2022-072 T2022-072 T2022-072 Test Number 17 18 19 Depth in Inches 12 12 12 Field Density. Lb/Cu.Ft (Wet Basis) 114.5 114.7 114.2 Field Density. Lb/Cu.Ft (Dry Basis) 104.3 104.0 103.8 Moisture Contents 9.8 10.3 10.0 Maximum Density in the Field (%) 99.0% 98.7% 98.5% Compaction Requirement by specs % of maximum density 98% 98% 98% 100% Maximum Density (lab) 105.4 105.4 105.4 Proctor T-180 AASHTO Method C 3/3177 3/3177 3/3177 Compaction Test Result PASS PASS PASS ' °:. Optimum Moisture 11.2 Remarks OX Tested By E.V/M.I Checked By MI FLORIDA CERTIFICATE OF AUTHORIZATION No.EB 7944 Respectfully Sub �t#d''��G E'ry 0.55538 STATE OF Aamir A. Ghori, P.E. # 5553& f I'-F t""' Should any subsoil conditions in the property (area) tested found different from that encountered on the tested locations reported on our Density Test, TASK LA9ORATORIES, INC. is not responsible. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential troperry of coents ana for pumcauons or statements or extract trom regaromg is reservea penang our wntten approval. SOIL & MATERIAL TESTING GEOTECHNICAL RXPLORATIONS QA/QC INSPECTIONS ENVIRONMENTAL AUDITS TASK LABOR4 TOR►ES, INC. 14241 SW 140 Street, Miami, Florida 33186 Proctor Compaction _Test Client RHR of Miami Inc. J.Iob No: I T2022-072 Address 4281 SW 139th Ave, Miramar, Florida 33027 Report No: 13 Project Single Family Residence Address 334 NE 102" Street, Miami Shores, Florida Matrix Light tan fine sand Source Of Material At Job site, material for subgrade of slab on grade Sample Location Job Site Sampling date 7/13/2022 Lab ID# 3177 Collected By R.S/T.H. Sample # 3 Analysis date 7/15/2022 Checked By M.I Analysis By E.V/R.S Approved By M.I TEST - RESULTS The following compaction test conducted in accordance with the standard/Modified Methods for Moisture Density Relations of soil using a 10 lb. Hammer and 18" drop AASHTO designation T-180 & ASTM D-1557. % MOISTURE DRY DENSITY 5.2 99.4 7.6 101.2 9.3 103.7 11.2 105.4 9.7 102.5 Optimum Moisture 11.2 100% Maximum Dry Density 105.4 98% Dry Density 103.3 95% Dry Density 100.1 110.0 108.0 106.0 104.0 H W 102.0 G c 100.0 98.0 96.0 0.0 ��v►{{11Pf}..`rFrr. f Respectfully Submitted, q,�. ��`, - °' ' ',` ' ° • r1 `• TASK LABORATORIES, INe- 55538 - IAT E OF Aamir A. Ghori, P.E. # 55538 2.0 4.0 6.0 8.0 10.0 12.0 14.0 % MOISTURE SOIL 8 MATERIAL TESTING GEOTECHNICAL INVESTIGATIONS INSPECTIONS ENVIRONMENTAL AUDITS