RF-12-21-3367 10334 N Miami AveCIVIL Reileh Engineering Corp.
(Consulting Engineer)
2370 Southwest 123,d Avenue
RaEl Miami, Florida 33175-1174
ENGINEER Tel: 305-823-8008 / 305-397-6414
June 9, 2022
Bassard Roofing
Miami, Florida
Project: ROOF TILE UPLIFT TEST REPORT
Residential Home
10334 North Miami Avenue
Miami Shores, Florida
Information provided by client:
Permit Number: Not Provided
f Date Completion: June 6, 2022
Roofing Contractor: Bassard Roofing
Project Number: 22-1068
(Testing Laboratory Certificate 4 16-0602.01)
Dear Sirs;
In accordance with your request and authorization, a representative of Reileh Engineering
Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was
performed in general accordance with Roofing Application Standard TAS No.106 -- Standard
procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically
attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was less than 10000 square feet, and the mean height of the
roof is less than 40 feet above ground su face. The type of tile used for this project was reported to
be concrete/clay Roof Tile. This the wall
reported to have been foamed in place.
At the time of our inspection, the entire area of the roof was examined for loose tiles. Not less than
one (1) the in ten (10) of all components in the field area and one (1) the in five (5) of all tiles in the
perimeter and corner areas were physically examined. A minimum of one (1) test per every two (2)
squares in the field, one (1) test per square in the perimeter area, ridge caps and one (1) test in each
corner were conducted.
Based on our test results, we conclude that the installation of the roof tile at he above referenced
project streets the test requirement outlined in the above -mentioned protocol. ttached please find
a copy of our test report for your review.
Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you
have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
Respectfully submitted;
Reileh Engineering Corporation
Mohamad Sonny Salleh, P.E.49014
Project Manager
TILE UPLIFT TEST
Residential Homc
10334 North Miami Avenue
Miami Shores, Florida
Submittals:
Cover Page
Page 2 thru 5 of 5
Drawing 22-1068
Reileh Engineering Corporation -- Project Number - 22-1068 — Page 2 of 5
Report of
TILE UPLIFT TEST
for
Residential Home
10334 North Miami Avenue
Miami Shores, Florida
Project Number: 22-1068
Test Number
1
2
3
4
5
6
7
Test Load (lb
35
35
35
35
35
35
35
Test Status
Pass
Pass
Pass
Pass
Pass
Pass
Pass
8
35
Pass
9
35
Pass
10
35
Pass
11
35
Pass
12
13
35
35
Pass
Pass
14
35
Pass
15
35
Pass
16
35
Pass
17
35
Pass
18
35
Pass
19
35
Pass
20
35
Pass
21
35
Pass
22
35
Pass
23
35
Pass
24
35
Pass
Reilch Engineering Corporation -- Project Number - 22-1068 — Page 3 of 5
Test Number
Test Load Zb
Test Status
25
35
Pass
26
35
Pass
27
35
Pass
28
35I
Pass
29
35
Pass
30
35
Pass
31
35
Pass
32
35
Pass
33
35
Pass
34
35
Pass
35
35
Pass
36
35
Pass
37
35
Pass
38
35
Pass
39
35
Pass
40
35
Pass
41
35
Pass
42
35
Pass
43
35
Pass
44
35
Pass
45
35
Pass
46
35
Pass
47
35
Pass
48
35
Pass
49
35
Pass
50
35
Pass
51
35
Pass
52
35
Pass
53
35
Pass
54
35
Pass
Reileh Engineering Corporation -- Project Number - 22-1068 — Page 4 of 5
mber
755
F35
Test Load Ib
Test Statys
Pass
56
35
Pass
57
35
Pass
58
35
Pass
59
35
Pass
60
35
Pass
61
35
Pass
Test 1-12 Corner, 13-19 Ridge Caps, 20-31 Perimeter, 32-61 Field