Loading...
RF-12-21-3367 10334 N Miami AveCIVIL Reileh Engineering Corp. (Consulting Engineer) 2370 Southwest 123,d Avenue RaEl Miami, Florida 33175-1174 ENGINEER Tel: 305-823-8008 / 305-397-6414 June 9, 2022 Bassard Roofing Miami, Florida Project: ROOF TILE UPLIFT TEST REPORT Residential Home 10334 North Miami Avenue Miami Shores, Florida Information provided by client: Permit Number: Not Provided f Date Completion: June 6, 2022 Roofing Contractor: Bassard Roofing Project Number: 22-1068 (Testing Laboratory Certificate 4 16-0602.01) Dear Sirs; In accordance with your request and authorization, a representative of Reileh Engineering Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 10000 square feet, and the mean height of the roof is less than 40 feet above ground su face. The type of tile used for this project was reported to be concrete/clay Roof Tile. This the wall reported to have been foamed in place. At the time of our inspection, the entire area of the roof was examined for loose tiles. Not less than one (1) the in ten (10) of all components in the field area and one (1) the in five (5) of all tiles in the perimeter and corner areas were physically examined. A minimum of one (1) test per every two (2) squares in the field, one (1) test per square in the perimeter area, ridge caps and one (1) test in each corner were conducted. Based on our test results, we conclude that the installation of the roof tile at he above referenced project streets the test requirement outlined in the above -mentioned protocol. ttached please find a copy of our test report for your review. Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; Reileh Engineering Corporation Mohamad Sonny Salleh, P.E.49014 Project Manager TILE UPLIFT TEST Residential Homc 10334 North Miami Avenue Miami Shores, Florida Submittals: Cover Page Page 2 thru 5 of 5 Drawing 22-1068 Reileh Engineering Corporation -- Project Number - 22-1068 — Page 2 of 5 Report of TILE UPLIFT TEST for Residential Home 10334 North Miami Avenue Miami Shores, Florida Project Number: 22-1068 Test Number 1 2 3 4 5 6 7 Test Load (lb 35 35 35 35 35 35 35 Test Status Pass Pass Pass Pass Pass Pass Pass 8 35 Pass 9 35 Pass 10 35 Pass 11 35 Pass 12 13 35 35 Pass Pass 14 35 Pass 15 35 Pass 16 35 Pass 17 35 Pass 18 35 Pass 19 35 Pass 20 35 Pass 21 35 Pass 22 35 Pass 23 35 Pass 24 35 Pass Reilch Engineering Corporation -- Project Number - 22-1068 — Page 3 of 5 Test Number Test Load Zb Test Status 25 35 Pass 26 35 Pass 27 35 Pass 28 35I Pass 29 35 Pass 30 35 Pass 31 35 Pass 32 35 Pass 33 35 Pass 34 35 Pass 35 35 Pass 36 35 Pass 37 35 Pass 38 35 Pass 39 35 Pass 40 35 Pass 41 35 Pass 42 35 Pass 43 35 Pass 44 35 Pass 45 35 Pass 46 35 Pass 47 35 Pass 48 35 Pass 49 35 Pass 50 35 Pass 51 35 Pass 52 35 Pass 53 35 Pass 54 35 Pass Reileh Engineering Corporation -- Project Number - 22-1068 — Page 4 of 5 mber 755 F35 Test Load Ib Test Statys Pass 56 35 Pass 57 35 Pass 58 35 Pass 59 35 Pass 60 35 Pass 61 35 Pass Test 1-12 Corner, 13-19 Ridge Caps, 20-31 Perimeter, 32-61 Field Reileh Engineering Corporation -- Project Number - 22-1068 — Page 5 of 5