RC-03-20-594 PLANSDRAWING LOG 03-23-20 Revision by owner SCALE'Ustu rLVVh( rLHIV ,&C CA SERIES 740 (D 17-0614.74 4 SERIES 740 -0614.14 4 SERIES 740 -0614.14 T. II SAFETY aSS 4 SERIES 740 -0614.14 CODE COMPLIANCE -THE PROJECT WAS DESIGNED IN ACCORDANCE WTH THE FLORIDA BUILDING, EXISTING BUILDING AND RESIDENTIAL CODE, 6TH EDITION (2017). -AS PER F.B.C. 310: USE CLASSIFICATION: R-3 RESIDENTIAL. -AS PER F.B.C. E.B. SECTION 504, LEVEL OF ALTERATION: ALTERATION LEVEL 2. SCOPE OF WORK 1- WINDOWS AND EXTERIOR DOORS REPLACEMENT. 2- ELECTRICAL PANEL REPLACEMENT. REFER TO ELECTRICAL PAGE FOR DETAILED SCOPE OF WORK E-101. EXTERIOR DOOR SCHEDULE 1 37" 64" 1 3/4" FIBERGLS METAL MTL. FIBERGLASS CONSTRUCTION OPAQUE SINGLE OUT -SWING DOOR/ IMPACT RESISTANT EXTERIOR HANDLE SET WITH DEAD BOLT/ CHROME FINISH FL#20470.1 - 2 33.5" 80" 1 g/q• METAL ALUM. MTL. ALUMINUN/GLASS CONSTRUCTION OUTSWING FRENCH DOOR/ IMPACT RESISTANT/ BRONZE FINISH/3/8" LAMINATED GLASS EXTERIOR HANDLE SET WITH DEAD BOLT/ CHROME FINISH 17-0504.01 /FD101H SERIES DIMENSIONS ARE FOR DOORS ONLY. G.C. SHALL VERIFY ALL DIMENSIONS AND QUANTITIES BEFORE ORDERING. WINDOWS SCHEDULE MARK TYPE W H REMARKS MANUFACTURER/MODEL NOA O CASEMENTXOX 108" 48" IMPACT RESISTANT/SM6" LAMINATED CLEAR GLASSI BRONZE FINISH/ CAT. SAFETY GLASS PGT INDUSTRIES/ CA SERIES 740 17-0614.14 CASEMENTXX 74" 40.5" IMPACT RESISTANT/ 5/16" LAMINATED CLEAR GLASS/ EGRESS/BRONZE FINISH PGT INDUSTRIES/ CA SERIES 740 17-0614.14 CASEMENTXX 55" 52.5" IMPACT RESISTANT/5/16" LAMINATED CLEAR GLASS/EGRESS/BRONZE FINISH PGT INDUSTRIES/ CA SERIES 740 17-0614.14 O CASEMENTX 36" 39.5" IMPACT RESISTANT/ 5M6" LAMINATED CLEAR GLASS/BRONZE FINISH/ CAT. SAFETY GLASS PGT INDUSTRIES/CA SERIES 740 17-0614.14 OE CASEMENT XOX 108" 60`' IMPACT RESISTANT/ 5/16" LAMINATED CLEAR GLASS/ BRONZE FINISH PGT INDUSTRIES/ CA SERIES 740 17-0614.14 OF CASEMENTXX 73" 52;5' IMPACT RESISTANT/ 5116" LAMINATED CLEAR GLASSIBRONZE FINISH/ CAT. SAFETY GLASS PGT INDUSTRIES/ CA SERIES 740 17-0614.14 O CASEMENTXX 52" 42.5" IMPACT RESISTANT/ 5116" LAMINATED CLEAR GLASS/ BRONZE FINISH PGT INDUSTRIES/ CA SERIES 740 17-0614.14 ALL WINDOWS AND FRENCH DOORS TO BE ALUMINUM NON THERMAL BRONZE FINISH G.C. SHALL VERIFY ALL DIMENSIONS AND QUANTITIES BEFORE ORDERING WINDOWS {\JM, ) &sie l..L. pW cr Q /U Ll. W •••"> A B s SeLJ .� •aaaa! • a �Myy Waae.dy �•-_. -Lys ,T L IL�d UJ U D LLI cot W Iz LL CL W U) U) cr rr U) 0 ® W zz z� �0 PH 0 a U J - J LL .J " 0 6 eil a Zor U L- z W z f— w J Oa Q ¢O LL W = O LL II- U 700 //� c U� V—, U) DRAWN BY: V.V.L REVIEW BY: J.D.M. SCALE: 1/4" = 1'-0" RELEASE DATE: 03-13-2020 A-201 FLOOR PLAN SHEET NO. 1 OF 2 I DRAVVING LOG 00-00-00 1 bldg, opt. comm. EXIST ELECTRI SER\ EXIST. OVERHEAD ELECT. SERVICE FROM FPL. 3# 2 THWN CU/2" C. EXISTING METER/MAIN COMBO NEMA3R 3/4"0 CWP OUTSIDE INSIDE NEW 2 POLE I EXISTING PANEL 100A 100A MAIN DISC (1OK AIC) — �7 METER 120/240V 2-1/2" C. VW� 3 #2 THWN CU & 1#4 THWN CU GROUND. PROVIDE ADDITIONAL 1#4 THWN (CLI) CONNECTION LISTED FOR USE IN 1/2" COND. AS GROUNDING AND BONDING EQUIPMENT AS PER NEC. 250.94 (2)10'-0" DEEP GROUNDING I / ROD - 1/2" DIAMETER EXISTING ELECTRICAL RISER N.T.S. PRIOR TO' 1INS!'1:1n Tr N R -,. u „. E'-141(. v". -y .. CHECK NAM,-PLA1E UNy: EQUIPMENT, HOT dr'i-i,.l. J:E AND OTHER EQUIPM+N! II--'` CORRECT WIRW &ZL- AN OVERCURRENT PRO%E; r :`a ADEQUATE SGRVIICE 1760"' *F?' AAUSI 99 PRO+'° .:%y INr. SERVICE CALCULATIONS GENERAL LIGHTS DRYER RANGE REFRIGERATOR MICROWAVEMOOD DISHWASHER SMALL APPLIANCES (3) GAS INSTANT WH GARAGE DOOR OPENER WASHER MACHINE TOTAL CONNECTED LOAD FIRST 10 KW @ 100% REST @ 40% A/C HEATER @ 100% TOTAL DEMAND LOAD 23.06 KW/ 240 v = 96 AMPS EXISTING SERVICE =1DO AMPS 4,854 5,000 8,500 1,500 1,500 1,200 4,500 800 800 1.500 30A5 KW 10.00 KW 8.06 KW 5.0 KW 23.06 KW 7 ELECTRICAL NOTES ELECTRICAL SYMBOL LEGEND 1) CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT 4"0 RECESSED LED LIGHT FIXTURES FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS, Q JUNCTION BOX 2) COMPLY WITH THE N.E.C. 2014 AND STANDARD BUILDING CODE. OF/LJB WISPECIAL SUPPORT FAN & LIGHT 3) PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. SM SENSOR MOVEMENT 4) OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. vQ VAPOR PROOF 5) PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER O CEILING MOUNTED FIXTURE TRADES. WALL MOUNTED FIXTURE 6) PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. O MOTOR FOR CHANDELIER 7) COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL PICTURE WALL MOUNTED FIXTURE FEATURES. - FLUORESCENT FIXTURE 8) CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. QUADRUPLEX RECEPTACLE 9) ALL CABLE SHALL BE COPPER. GFI GFI RECEPTACLE 10) INDOOR CONDUIT SHALL BE EMT. SINGLE RECEPTACLE 2 POLE OUTLET 11) ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. RECEPTACLE 12) OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. SWITCHABLE DUPLEX RECEPTACLE UNDER PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUM GARBAGE DISPOSAL COVER SHALL BE 241NCHES. OUTDOOR CONDUIT SHALL BE EMT SPOTLIGHT 13) G.C. TO PROVIDE IN AND OUT ALL SLEEPING AREAS SMOKE DETECTORS AS REQUIRED. o ELECTRIC PANEL I rN il EXHAUST FAN SPECIAL NOTES: WP WEATHER PROOF $ SWITCH 1. SMOKE DETECTORS SHALL BE HARDWIRE (110 VOLT TYPE) TO A NON SWITCH ABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT WITH BATTERY BACK UP AND $- 3WAY SWITCH SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT LOW VOLTAGE SYSTEM SWITCH (DIMMER) INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED. 1 TELEPHONE 2. SMOKE DETECTORS SHALL NOT BE PLACED WITHIN 3 FT OF ANY A/C GRILL 3. INDOOR CONDUIT SHALL BE EMT.. rvO TELEVISION CABLE OUTLET 5. OUTDOOR CONDUIT SHALL BE EMT. gD SMOKE DETECTOR/CARBON MONOXIDE 6. OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC UNDER COMBINATION PAVED AREAS IT SHALL BE ENCASED IN CONCRETE. MINIMUN COVER SHALL BE 18" 7. ALL ELECTRICAL AND TELEPHONE OUTLETS TO BE INSTALLED AT 18" AFF. UON. © GARAGE DOOR OPENER CONTROLLER 8. ALL RECEPTACLES AT IMPACT AREAS TO BE TAMPER RESISTANT TO COMPLY WITH NEC 406.12. N� INTERCOM 9. ALL NEW/RELOCATED OR MODIFIED RECEPTACLES AT IMPACT AREAS (EXCEPT GFI) TO BE AFCI AS PER NEC 210.12 DB DOORBELL 10. ALL RECEPTACLES AT COUNTER TO BE INSTALLED AT 48" A.F.F. 11. A MINIMUM OF 75% OF THE LAMPS TO BE INSTALLED SHALL BE HIGH -EFFICACY LAMPS, TO COMPLY WITH F.B.C. 2014 E.C. R404. 12. PROVIDE A MINIMUM OF 1 FOOT CANDLE ILLUMINATION AT STAIR TO COMPLY WITH F.B.C. R 303.7 2014 EDITION. 100AMPS AC 10,000 M.LO, NEW PANEL 1201240V 1-3W MOUNTED -FLUSH CKT SERVES CS P VA WIRE CKT SERVES CB P VA WIRE 01 RANGE 50 2 8,400 #8 02 DRYER 30 2 5,000 #10 03 04 05 GENERAL L & R 15 1 # 14 06 DISHWASHER 20 1 1,200 # 12 07 REFRIGERATOR 20 1 1,500 # 12 08 GARAGE DOOR OPENER 20 1 800 # 12 09 GENERAL L & R 15 1 # 14 10 GFI BATHRM. 20 1 # 12 11 MICROWAVE I HOOD 20 1 1,500 It 12 Q WASHER MACHINE 20 1 1,500 # 12 13 GENERAL L&R 15 1 #14 14 GENERAL L & R 15 1 #10 15 GENERAL L & R 15 1 # 14 16 SMALL APPLIANCES 20 1 1,500 # 12 17 GENERAL L & R 15 1 914 18 SMALL APPLIANCES 20 1 1,500 # 12 19 GAS WATER HEATER 20 1 800 # 12 20 SMALL APPLIANCES 20 1 1,500 # 12 21 AHU 30 2 5,000 # 10 22 CU 20 2 21000 # 12 23 24 DENOTES AFCI ° ZI�'G G �G I G / C- FT `sG A-D fr A/ AREA 1,618 SO, FT. '3VA=4,854 VA ,r ,sUL yA. �Gr/C,per f?/Zp-AJIwf 5' -�r p9-jw-D5D I ELECTRICAL SCOPE OF WORK I 1- ELECTRICAL PANEL REPLACEMENT. INSTALLATION OF MAIN DISCONNECT. 2- RE -WIRING ALL LIGHT FIXTURES AND RECEPTACLES. (REMOVAL OF CLOTH WIRES) 3- INSTALLATION OF EXTERIOR LIGHTING. UNLESS OTHERWISE NOTED ALL LIGHT FIXTURES, APPLIANCES, EQUIPMENT AND RECEPTACLES ARE EXISTING TO REMAIN, ELECTR CAL REVIEW APPC�VE�pATE VJ ui- U= U W Q W �'A Q W co F— Cr CO T (M W U HLLJ °C w0 Cr ILL LLJ U 11. � v ) Lu VJ cr D o0T I---r Oz z- Z� d-Q �0T O C0 0 N r J 6 � J LL- ° G F.77 a ° JQ ° o O ° z0o LL Z ° W <w Z L G ? J oa 0 Cr N� Q ¢ O J cc WL 0� UO H I. r 0 DRAWN BY: V.V.L REVIEW BY: J.D.M. SCALE: 1 /4" = 1'-0" RELEASE DATE: 03-13-2020 E-1 01 ELECTRICAL PLAN SHEET NO. 1 OF I