Loading...
RC-088-19-1827 PLANSAA 26002308 MR. ARCHITECT .f LLC MIGUEL RIONDA, ARCHITECT, AR 94189 13899 Biscayne Blvd., Suite 308 North Miami Beach, FL 33162 305-527-8815 miguel@mr-architect.com www.mr-architect.com GENERAL OUTLINE SPECIFICATIONS PART 1.0 - GENERAL THE FOLLOWING OUTLINE SPECIFICATIONS ARE INTENDED TO PROVIDE MATERIALS AND SYSTEMS TO COMPLY WITH ARCHITECT DESIGN INTENT. THESE SPECIFICATIONS ARE FOR GENERAL GUIDELINE PURPOSES FOR THE PROJECT AND BY NO MEANS ARE TO BE CONSIDERED COMPLETE SPECIFICATIONS FOR ALL REQUIRED MATERIALS FOR THIS PROJECT. THE ITEMS LISTED BELOW REPRESENT ONLY THE BASIC REQUIREMENTS AND THE MATERIALS THAT THE ARCHITECT HAS SELECTED. THE CONTRACTOR SHALL REVIEW THE REQUIREMENTS OF THE GUIDELINE AND PROVIDE MATERIALS AND ANY OTHER REQUIRED ACCESSORY OR SERVICE TO PROVIDE A COMPLETE SYSTEM OR PRODUCT FOR THE INTENDED USES. ALL MATERIAL AND WORKMANSHIP FOR EACH MATERIAL IN THIS PROJECT SHALL BE AS RECOMMENDED BY THE MANUFACTURE OF THE PRODUCT AND/OR ANY INDUSTRY CODE OR STANDARD THAT MAY APPLY. UNLESS DIRECTED OTHERWISE BY THESE DRAWINGS, ALL OTHER ELEMENTS INCLUDING, COLUMNS, WALLS, EQUIPMENT, ELECTRICAL OUTLETS, MECHANICAL VENTS, AND FIXTURES ARE EXISTING TO REMAIN. UNIT COMPLIES WITH ALL CODE REQUIREMENTS, ALL NECESSARY LIFE SAFETY EQUIPMENT IS EXISTING AND FUNCTIONING, INCLUDING SMOKE ALARMS AND FIRE SPRINKLERS. THESE ITEMS ARE BEING OMITTED FROM THESE DRAWINGS AND ARE NOT BEING AFFECTED BY THE SCOPE OF WORK IN THIS PROJECT. THESE ITEMS MAY BE ADDRESSED BY THE INSPECTORS AT THE TIME OF INSPECTIONS. CONTRACTOR AGREES THAT HE WILL HOLD OWNER, ARCHITECT, ENGINEERS, AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, HARMLESS FROM ANY AND ALL DAMAGE AND CLAIMS WHICH MAY ARISE BY REASON OF ANY NEGLIGENCE ON THE PART OF THE CONTRACTOR, OR ANY OF HIS SUBCONTRACTORS, OR ANY MATERIAL AND EQUIPMENT SUPPLIERS, AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, IN THE PERFORMANCE OF THIS CONTRACT. IN CASE ANY ACTION IS BROUGHT AGAINST THE OWNER, OR ARCHITECT, OR ENGINEER, OR ANY OF THEIR EMPLOYEES OR AGENTS, CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DEFENSE THEREOF, TO THE FULL SATISFACTION OF THE LATTER PARTY. THE CONTRACTOR SHALL PERFORM THE WORK IN COMPLIANCE WITH THESE DOCUMENTS AND THE REQUIREMENTS SET FORTH IN ALL APPLICABLE CODES AND REGULATIONS. THE CONTRACTOR SHALL EXAMINE ALL EXISTING CONDITIONS AND REVIEW THESE DRAWINGS AND ANY OTHER RELATED DOCUMENTS AND/OR SHOP DRAWINGS AND REPORT TO ARCHITECT ANY DISCREPANCIES PRIOR TO THE COMMENCEMENT OF THE WORK. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO WORK ALL INSERTS, ANCHORS, SLEEVES, OPENINGS, AND DEPRESSIONS AND PITCHES AS REQUIRED TO ACCOMMODATE WORK. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ANY SPECIFIC ARRANGEMENTS AS NEEDED DURING DEMOLITION AND CONSTRUCTION. ALL HARDWARE, BATHROOM & LIGHTING FIXTURES, CASEWORK, AND FINISH MATERIALS SPECIFICATIONS OMITTED IN THESE DRAWINGS ARE SUBJECT TO THE OWNER'S SELECTION. THE CONTRACTOR SHALL MAKE AND HIGHLIGHT THE PROPER ALLOWANCES, AND COORDINATE WITH THE OWNER FOR PURCHASING AND DELIVERY. THE CONTRACTOR MUST ENSURE TO PROTECT AND MAINTAIN ACTIVE ALL LIFE SAFETY FIXTURES AND APPLIANCES DURING AND AFTER CONSTRUCTION. ALL INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS'A' OR'B', FLAME SPREAD INDEX 0-25 FOR 'A' FINISHES, 26-75 FOR 'B' FINISHES, SMOKE DEVELOPED INDEX 0-450 AS PER NFPA ANNEX A 10.2.2. INSULATION IN CONCEALED SPACES SHALL BEAR FLAME SPREAD RATING OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF NOT MORE THAN 450. CELULOSE LOOSE -FILL INSULATION SHALL MEET ONLY SMOKE DEVELOPEDINDEX OF NOT MORE THAN 450. INSTALLATION, INCLUDING ALL OBVIOUSLY NECESSARY ITEMS EVEN THOUGH SUCH ITEMS ARE NOT INDICATED WITHIN THE CONSTRUCTION DOCUMENTS. ALL CONSTRUCTION METHODS, MATERIALS, ETC. SHALL MEET OR EXCEED ANY AND ALL APPLICABLE BUILDING CODES, STANDARDS AND OR ORDINANCES. 390 NE 101 st STREE MIAMI SHORES, FL 33150 Sheet List Sheet Sheet Issue T Current Current Revision Number Sheet Name Date Current Revision Revision Date 1 Description 0.00 Cover 8/1/19 2 10/18/19 Revision 2 A-1.0 i Floor Plan 8/1/19 1 8/29/19 Revision 1 E-1.0 iElectrical Sheet - 8/1/19 _ - - 1 -- 8/29/19 Revision 1 P-1.0 (Plumbing Details 8/1/19 OWNERS: MARTIN SCOPE OF WORK • RENOVATE BATHROOM LOCATION PLAN NORTH DEMOLITION NOTES: THE CONTRACTOR SHALL EXAMINE ALL EXISTING CONDITIONS AND REVIEW THESE DRAWINGS AND ANY OTHER RELATED DOCUMENTS AND/OR SHOP DRAWINGS AND REPORT TO ARCHITECT ANY DISCREPANCIES PRIOR TO THE COMMENCEMENT OF THE WORK. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ANY SPECIFIC ARRANGEMENTS AS NEEDED DURING DEMOLITION. THE CONTRACTOR SHALL PROVIDE ALL OF THE NECESSARY RESOURCES INCLUDING LABOR, MATERIALS, EQUIPMENT, ETC. FOR THE COMPLETION OF ALL DEMOLITION WORK AS INDICATED OR IMPLIED BY THE DRAWINGS. THE CONTRACTOR SHALL CONFIRM WITH THE OWNER TO DEMOLISH, REMOVE AND DISPOSE OF ALL ITEMS AND MATERIALS INDICATED OR IMPLIED BY THE DRAWINGS UNLESS OTHERWISE DIRECTED BY THE OWNER. THE CONTRACTOR SHALL WORK IN A MANNER REQUIRED TO PROTECT EXISTING AREAS WHICH ARE NOT PART OF THE WORK. THE DEMOLITION CONTRACTOR SHALL COORDINATE ALL WORK WITH THE OWNER PRIOR TO COMMENCEMENT. THE CONTRACTOR SHALL VERIFY THE LOCATION OF UTILITIES DURING THE DEMOLITION WORK AND SHALL INSURE THAT UTILITIES ARE PROTECTED FROM DAMAGE. NO UTILITY SHALL BE DISCONNECTED WITHOUT CONSENT FROM THE OWNER OR ITS AUTHORIZED REPRESENTATIVE OR THE BUILDING ASSOCIATION. THE CONTRACTOR SHALL COMPLY WITH ALL PROTOCOLS AS DETERMINED BY THE AHJ. CONDUCT REMOVAL OPERATIONS OF DEBRIS TO MAINTAIN TRAFFIC ALONG EXISTING HALLWAYS, WALKWAYS, AND PUBLIC AREAS. KEEP COMMON AREAS AND SIDEWALKS FREE OF DEBRIS. REMOVE MATERIAL AND OTHER MATTER TRACKED OR FALLEN ONTO TRAFFIC SURFACES IMMEDIATELY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS, DEBRIS, AND DUST RESULTING FROM DEMOLITION. DISPOSE OF DEBRIS LEGALLY ON OR OFF SITE. USE APPROVED • • FLORIDA BUILDING CODE EXISTING. 2017 • FLORIDA BUILDING CODE, 2017 • NFPA 70, NATIONAL ELECTRICAL CODE (NEC 2014) • NFPA 101, NATIONAL LIFE SAFETY CODE (2015) • FFPC 6TH EDITION. • WORK TO BE PERFORMED IN EXISTING TO BE CLASSIFIED AS A LEVEL 2 ALTERATION AS DEFINED BY 2017 FBC(E) CHAPTER 5. LEVEL 2 ALTERATION SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 7. a rtfio; 11-320&-013 521 a r€ P _ Pik ti Piz pmrslar 3 00SGL.A, _e- p0mary tanl Use L, ng)Area 2y ; Adjust d Anaa Lot Size Year Built, - EXISTING FRONT DOOR hlt."t,_: 'SCOPE OF WORK IS LIMITED TO Demolition Plan = S. PORTION OF THE RESIDENCE �� 1 /2,, = 1,40 Y E XIQT!NG SMOKE ALARMS, INTFRCONNECTED w.l.� Bedroom Bedroom _1e,4ee B Bedroom Fire Alarm Plan 1/8 = 1,-0„ SHOWER AND OF CLOSET TO �LISHED .IEF;_ l L._ •m • • 3 • • 6 pqE O y..GJ lGN CIO R,OtiO9 9 A 9 189 S FAT^�0�^a\�� AA 26002308 MR. ARCHITECT, LLC MIGUEL RIONDA, ARCHITECT, AR 94189 13899 Biscayne Blvd., Suite 308 North Miami Beach, FL 33162 305-527-8815 miguel@mr-architect.com www.mr-architect.com GENERAL OUTLINE SPECIFICATIONS PART 1.0 - GENERAL THE FOLLOWING OUTLINE SPECIFICATIONS ARE INTENDED TO PROVIDE MATERIALS AND SYSTEMS TO COMPLY WITH ARCHITECT DESIGN INTENT. THESE SPECIFICATIONS ARE FOR GENERAL GUIDELINE PURPOSES FOR THE PROJECT AND BY NO MEANS ARE TO BE CONSIDERED COMPLETE SPECIFICATIONS FOR ALL REQUIRED MATERIALS FOR THIS PROJECT. THE ITEMS LISTED BELOW REPRESENT ONLY THE BASIC REQUIREMENTS AND THE MATERIALS THAT THE ARCHITECT HAS SELECTED. THE CONTRACTOR SHALL REVIEW THE REQUIREMENTS OF THE GUIDELINE AND PROVIDE MATERIALS AND ANY OTHER REQUIRED ACCESSORY OR SERVICE TO PROVIDE A COMPLETE SYSTEM OR PRODUCT FOR THE INTENDED USES. ALL MATERIAL AND WORKMANSHIP FOR EACH MATERIAL IN THIS PROJECT SHALL BE AS RECOMMENDED BY THE MANUFACTURE OF THE PRODUCT AND/OR ANY INDUSTRY CODE OR STANDARD THAT MAY APPLY. UNLESS DIRECTED OTHERWISE BY THESE DRAWINGS, ALL OTHER ELEMENTS INCLUDING, COLUMNS, WALLS, EQUIPMENT, ELECTRICAL OUTLETS, MECHANICAL VENTS, AND FIXTURES ARE EXISTING TO REMAIN. UNIT COMPLIES WITH ALL CODE REQUIREMENTS, ALL NECESSARY LIFE SAFETY EQUIPMENT IS EXISTING AND FUNCTIONING, INCLUDING SMOKE ALARMS AND FIRE SPRINKLERS. THESE ITEMS ARE BEING OMITTED FROM THESE DRAWINGS AND ARE NOT BEING AFFECTED BY THE SCOPE OF WORK IN THIS PROJECT. THESE ITEMS MAY BE ADDRESSED BY THE INSPECTORS AT THE TIME OF INSPECTIONS. CONTRACTOR AGREES THAT HE WILL HOLD OWNER, ARCHITECT, ENGINEERS, AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, HARMLESS FROM ANY AND ALL DAMAGE AND CLAIMS WHICH MAY ARISE BY REASON OF ANY NEGLIGENCE ON THE PART OF THE CONTRACTOR, OR ANY OF HIS SUBCONTRACTORS, OR ANY MATERIAL AND EQUIPMENT SUPPLIERS, AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, IN THE PERFCRMANCE OF THIS CONTRACT. IN CASE ANY ACTION IS BROUGHT AGAINST THE OWNER, OR ARCHITECT, OR ENGINEER, OR ANY OF THEIR EMPLOYEES OR AGENTS, CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DEFENSE THEREOF, TO THE FULL SATISFACTION OF THE LATTER PARTY. THE CONTRACTOR SHALL PERFORM THE WORK IN COMPLIANCE WITH THESE DOCUMENTS AND THE REQUIREMENTS SET FORTH IN ALL APPLICABLE CODES AND REGULATIONS. THE CONTRACTOR SHALL EXAMINE ALL EXISTING CONDITIONS AND REVIEW THESE DRAWINGS AND ANY OTHER RELATED DOCUMENTS AND/OR SHOP DRAWINGS AND REPORT TO ARCHITECT ANY DISCREPANCIES PRIOR TO THE COMMENCEMENT OF THE WORK. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO WORK ALL INSERTS, ANCHORS, SLEEVES, OPENINGS, AND DEPRESSIONS AND PITCHES AS REQUIRED TO ACCOMMODATE WORK. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ANY SPECIFIC ARRANGEMENTS AS NEEDED DURING DEMOLITION AND CONSTRUCTION. ALL HARDWARE, BATHROOM & LIGHTING FIXTURES, CASEWORK, AND FINISH MATERIALS SPECIFICATIONS OMITTED IN THESE DRAWINGS ARE SUBJECT TO THE OWNER'S SELECTION. THE CONTRACTOR SHALL MAKE AND HIGHLIGHT THE PROPER ALLOWANCES. AND COORDINATE WITH THE OWNER FOR PURCHASING AND DELIVERY. THE CONTRACTOR MUST ENSURE TO PROTECT AND MAINTAIN ACTIVE ALL LIFE SAFET( FIXTURES AND APPLIANCES DURING AND AFTER CONSTRUCTION. ALL INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS W OR 'B', FLAME SPREAD INDEX 0-25 FORA' FINISHES, 26-75 FOR'B' FINISHES, SMOKE DEVELOPED INDEX 0-450 AS PER NFPA ANNEX A 10.2.2. INSULATION IN CONCEALED SPACES SHALL BEAR FLAME SPREAD RATING OF NOT MORE THAN 25 AND SMOKE DEVELOPED INDEX OF NOT MORE THAN 450. CELULOSE LOOSE -FILL INSULATION SHALL MEET ONLY SMOKE DEVELOPEDINDEX OF DOT MORE THAN 450. INSTALLATION, INCLUDING ALL OBVIOUSLY NECESSARY ITEP.'S EVEN THOUGH SUCH FEMS ARE NOT INDICATED WITHIN THE CONSTRUCTION DOCUMENTS. ALL CONSTRUCTION METHODS, MATERIALS, ETC. SHALL MEET OR EXCEED ANY AND ALL APPLICABLE BUILDING CODES, STANDARDS AND OR ORDINANCES. ONE-STORY RESIDENCE BATHROOM RENOVATION 390 NE 101st STREET, MIAMI SHORES, FL 331501 OWNERS: MARTIN LOCATION PLAN NORTH DEMOLITION NOTES: THE CONTRACTOR SHALL EXAMINE ALL EXISTING CONDITIONS AND REVIEW THESE DRAWINGS AND ANY OTHER RELATED DOCUMENTS AND/OR SHOP DRAWINGS AND REPORT TO ARCHITECT ANY DISCREPANCIES PRIOR TO THE COMMENCEMENT 0= THE WORK. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ANY SPECIFIC ARRANGEMENTS AS NEEDED DURING DEMOLITION. THE CONTRACTOR SHALL PROVIDE ALL OF THE NECESSARY RESOURCES INCLUDING LABOR, MATERIALS, EQUIPMENT, ETC. FOR THE COMPLETION OF ALL DEMOLITION WORK AS INDICATED OR IMPLIED BY THE DRAWINGS. THE CONTRACTOR SHALL CONFIRM WITH THE OWNER TO DEMOLISH, REMOVE AND DISPOSE OF ALL ITEMS AND MATERIALS INDICATED OR IMPLIED BY THE DRAWINGS UNLESS OTHERWISE DIRECTED BY THE OWNER. THE CONTRACTOR SHALL WORK IN A MANNER REQUIRED TO PROTECT EXISTING AREAS WHICH ARE NOT PART OF THE WORK. THE DEMOLITION CONTRACTOR SHALL COORDINATE ALL WORK WITH THE OWNER PRIOR TO COMMENCEMENT. THE CONTRACTOR SHALL VERIFY THE LOCATION OF UTILITIES DURING THE DEMOLITION WORK AND SHALL INSURE THAT UTILITIES ARE PROTECTED FROM DAMAGE. NO UTILITY SHALL BE DISCONNECTED WITHOUT CONSENT FROM THE OWNER OR ITS AUTHORIZED REPRESENTATIVE OR THE BUILDING ASSOCIATION. THE CONTRACTOR SHALL COMPLY WITH ALL PROTOCOLS AS DETERMINED BY THE AHJ. CONDUCT REMOVAL OPERATIONS OF DEBRIS TO MAINTAIN TRAFFIC ALONG EXISTING HALLWAYS, WALKWAYS, AND PUBLIC AREAS. KEEP COMMON AREAS AND SIDEWALKS FREE OF DEBRIS, REMOVE MATERIAL AND OTHER MATTER TRACKED OR FALLEN ONTO TRAFFIC SURFACES IMMEDIATELY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS, DEBRIS, AND DUST RESULTING FROM DEMOLITION. DISPOSE OF DEBRIS LEGALLY ON OR OFF SITE. USE APPROVED METHODS. SCOPE OF WORK • RENOVATE BATHROOM APPLICABLE CODES • FLORIDA BUILDING CODE EXISTING, 2017 • FLORIDA BUILDING CODE, 2017 • NFPA 70, NATIONAL ELECTRICAL CODE (NEC 2014) • NFPA 101, NATIONAL LIFE SAFETY CODE (2015) • FFPC 6TH EDITION. • WORK TO BE PERFORMED IN EXISTING TO BE CLASSIFIED AS A LEVEL 2 ALTERATION AS DEFINED BY 2017 FBC(E) CHAPTER 5. LEVEL 2 ALTERATION SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 7. Folio: 1:9 3206- 13-52EG MI St IICTAE iSEC I kYU Property Address ,5w".,; u _ —- 'k t :(3 by il. ;REE FL aIQP 24?S lA i. Bed-, 01iths Half Floors Living Units Actual Area , 2 7 C S .=t Living Area 2ji57 B; Ft Adjusted Area s =t Year Built iF ul ie k'see B `, no Inloj PROPERTY INFORMATION L % S 1&2BLK39 LOT SiZE I026,513 X 11 LEGAL DESCRIPTION Sheet List Sheet Sheet Issue Current Current Revision Number Sheet Name Date Current Revision' Revision Date Description 0.00 Cover 8/1/19 A-1.0 Floor Plan 8/1/19 E-1.0 Electrical Sneet 8/1/19 P-1.0 Plumbing Details 8/1/19 Demolition Plan 1/2" = 1'-01, NOTE: SCOPE OF WORK IS LIMITED TO THIS PORTION OF THE RESIDENCE \q -Gil tLAGE MIRMI STi06:-5:- --^"� DATE pPYROVED ZONING ELECTR�G-� L PLUMBING ��3 / BLDG- MPLIANiE WIiN ?LL 10, R.',L. SUBJECT TO CO a REGULPtWt+: STATE ANL' GDUN11 RULES NO OF FAO P- IGNACIO Ri�tio 9 9 A �9 ) SHOWER AND I OF CLOSET TO ILISHED )BATHROOM S TO BE HED IVp10 iK"q wv. i rd 3 L 1 Im U C I D I E CEILING INSULATION UNDERSIDE OF JOISTS / CEILING 8'-0" AFF 2 x 6 WD TOP PLATE, NAIL TO RAFTER ABOVE @12" O.C., ALSO TO ACT AS FIRE STOP AT 8'-0" 2 x 6 - STUD FRAMING @16" O.C., TOE -NAIL TO RUNNERS, TOP AND BOTTOM, BATT INSULATION OPTIONAL k" GWB, PATCH AND PAINT 12' HARDIBOARD, PATCH AND PAINT SEALANT CONT. AT TOP AND BOTTOM x 6 WD RUNNER, NAIL TO JOISTS ILE CN THINSET MORTAR, ROUT AND SEAL ILE ON THINSET MORTAR, ROUT AND SEAL (ISTING SUB FLOOR WISH FLOOR BATHROOM PARTITION SCALE: N.T.S. Floor Plan 1 1/2" = 1'-0" NOTE: SHOWER PAN LINER BY OATEY ORSIMILAR, PVC CONSTRUCT, MEETS ASTM D4551 AS PER FBC P2709.2 TILE ON THIN SET, ON ALL SIDES OF SHOWER WALLS MIN. 72" A.F.F. 1/2" HARDI-BACKER BOARD, SCREWED TO FURRING WATER RESISTANT MEMBRANE (SHOWER PAN) LINE WALLS TO 12" AFF Z__ EXISTING FLOOR SLAB 1/2" GLASS, CATEGORY II SAFETY GLASS CLEAR SILICON CAULKING EXISTING FLOOR DRAIN SLD�.25/12 TO DRAIN C i EXISTING FLOOR SLAB I SHOWER PAN DETAIL NEW MEDICINE CABINET, WALL MOUNTED 10 CMU NEW VANITY/SINK AND FIXTURE TO CONNECT TO EXISTING DRAIN AND WATER LINE NEW SHOWER GLASS DOOR AND PARTITION, CAT. II SAFETY GLASS NEW SHOWER AND SHOWER PAN, TILE TO LINE WALLS TO CEILING, MIN. 70" AFF 2 J 2 1 ARCHITECT OF RECORD MR. ARCHITECT, LLC AA 26002308 MIGUEL RIONGA LIC. # AR 94189 13899 BISCAYNE FOULEVARD SUITE 308 NORTH MIAMI BEACH, FLORIDA 33162 o: 305.600.4399 info@mr-architect.com Drawings are subject to modification or change as required by actual measurements, standard Industry practices in light of existing structural and other conditions applicable building codes, and the like. These plans are and shall remain the property of MR. Architect, LLC and shall not be sold or reproduced without prior written consent. MR. Architect, LLC shall be notified of any changes required by actual conditions prior to execution of said changes for any phase for construction. 2919, MR, Architect, LLC SIGN AND SEAL of-F�a \GNACIO AR1,41Att p �. 11A.'l.Gd ADDRESS: 390 N E 101 st Street Miami Shores, FL 33150 PROJECT. Bathroom Renovation OWNER/BUILDER; Martin SHEET TITLE. - Floor Plan No. Fbescription Date 1 Revision 1 8/29/19 Project Number: 31 2019 Date: 8/1 /19 Drawn By: MR, Checked By: MR Scale: 1 /211 - 0 C X W N 1 N ELECTRICAL SCOPE OF WORK: ELECTRICAL WORK TO BE PERFORMED IN RENOVATED BATHROOM. INSTALL NEW INSTANT HOT WATER HEATER BOOSTER. ELECTRICAL NOTES: ALL WORK SHALL BE PERFORMED TO MEET THE REQUIREMENTS OF THE GOVERNING EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) 2014, LOCAL AND STATE CODES AND ANY OTHER APPLICABLE CODES AND STANDARDS. THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF THE ELECTRICAL SERVICE, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CHECK NAMEPLATE DATA OF ALL EQUIPMENT FOR REQUIRED VOLTAGES, MIN. CIRCUIT AMPACITY, AND OVERCURRENT PROTECTION. ALL WIRING SHALL BE COPPER (CU) THWN INSULATION. ALL CIRCUIT BREAKERS SHALL BE RATED MIN. 10,000 AIC. ALL BRANCH CIRCUITS SHALL BE PROPERLY PHASE BALANCED. TYPEWRITTEN PANEL TALLY SHALL BE FURNISHED AFTER JOB IS COMPLETED TO REFLECT ALL CHANGES AND ADDITIONS FOR EXISTING PANEL. GFCI PROTECTION NOTE: ALL BRANCH CIRCUITS THAT SUPPLY 125V, 1 PH, 15 AND 20 AMP RECEPTACLE OUTLETS INSTALLED IN BATHROOMS, KITCHENS, LAUNDRY CLOSET, OR WHERE RECEPTACLE IS INSTALLED WITHIN 6ft. OF OUTSIDE EDGE OF SINK SHALL HAVE GFCI PROTECTION IN COMPLIANCE W/ 210.8 NEC 2014. THE FOLLOWING SHALL BE DIRECTLY CONNECTED TO AN INSULATED COPPER EQUIPMENT GROUNDING CONDUCTOR INSTALLED WITH THE BRANCH CIRCUIT CONDUCTORS IN THE WIRING METHODS AS PROVIDED: 1. THE GOUNDING TERMINALS OF ALL RECEPTACLES. 2. METAL BOXES AND ENCLOSURES CONTAINING RECEPTACLES. 3. ALL NON -CURRENT -CARRYING CONDUCTIVE SURFACES OF FIXED ELECTRICAL EQUIPMENT LIKELY TO BECOME ENERGIZED THAT ARE SUBJECT TO PERSONAL CONTACT, OPERATING AT OVER ARC. FAULT CB INTERRUPTER PROTECTION NOTE: ALL BRANCH CIRCUITS THAT SUPPLY 125V, 10, 15 AND 20 AMP RECEPTACLE OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS, LIVING, DINING, AND STUDY ROOMS, HALLS, AND CLOSETS, SHALL BE PROTECTED BY ARC FAULT CIRCUIT INTERRUPTER(S) & IN COMPLIANCE W/ 210.12 (a) & (b) , IN` EVERY1KITCHEN, FAMILY ROO9,, DINING ROOM -LIVING -ROOM, - PARLOR, LIBRARY, DEN, SUNROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF DWELLING UNIT, A RECEPTACLE OUTLET SHALL BE INSTALLED SUCH THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WAL_ SPACE IS MORE THAN 6' FROM A RECEPTACLE OUTLET. ALL RECEPTACLES TO BE TAMPER RESISTANT. A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL COUNTERTOP SPACE THAT IS 12" OR WIDER. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE IS MORE THAN 24" MEASURED HORIZONTALLY FROM A RECEPTACLE OUTLET IN THAT SPACE. 0 B I c PROJECT: 390 NE 101 St Bathroom Renovation PROJECT NO: :31 2019 LINE TO LINE 'V❑LTAG 1201,240 - s L❑CATI❑N WEST EXTERI❑R WALL PHASE: 1 TYPE: EXISTING EXISTING PANEL m A '� RATING: 200 AMP SERVICE: 1PH, 3W, 601-12 NEUTRAL: 100 AMP VOLTAGE : 1201240 INTEGRATED EQUIPMENT SHORT CIRCUIT RATING: MAINS: M.L.O. M❑UNTINE ON WALL 10000 AMPS SYMMS. @ 240'V. (U.L. LISTED) LOCATION : TOP KW WIRE SIZE TRIP AMP ❑LE LOAD DESCRIPTION CK. f CKT AND REh/1ARKS NO. NO. LOAD DESCRIPTION AND REMARKS ❑LE TRIP AMP WIRE SIZE K.tJ 12 20 DINING ROOM " 1 2- -3 4- MASTER BATHROOM j 20 12 1.50 12 20 1 SMALL APPLIANCE AIR HANDLER 2 50 6 4.60 12 20 1 KITCHEN - -5 6 - -7 8- 1.50 12 20 1 FREEZER is DRYER 2 30 10 5.00 1.20 12 20 1 MICROWAVE " -9 10- -11 12 1.50 12 20 1 SMALL APPLIANCE POOLPUMP 2 30 10 2.00 1.40 12 20 1 DISHWASHER -13 14- -15 16- 12 20 1 BEDROOM RANGE 2 50 6 6.40 12 20 1 BEDROOM -17 18- -19 20- -21 22- -23 24- -25 26- -27 28- -29 30- -31 32- 12 20 1 COMPUTER WASHER 1 20 12 1.50 12 20 1 BEDROOM " HOOD 1 20 12 0.50 12 20 1 MASTER BEDROOM " LIVING ROOM 1 20 12 12 20 1 LIGHTS 'sm ENTRY mi" 1 20 12 12 20 1 LIGHTS LAUNDRY „ 1 20 12 12 20 1 LIGHTS " LIVING ROOM 1 20 12 12 20 1 ROOM WATER HEATER 2 30 10 5.50 12 20 1 BATHROOM -33 34- -35 36- -37 38- 12 20 1 LIVING ROOM LIGHTS 1 20 20 1.20 12 20 1 REFRIGERATOR 35 40- WATER HEATER 2 40 8 6.00 12 20 1 LAUNDRY " 8.30 31.50 FIRST 10.00 KW @ 1000/. 10.00 KW AC 1 100% 5.00 KW 2900 SF x 3VANSF = 8.70 kW REMAINDER Oo 40% 15.40 k' i TOTAL 30.40 KW TOTAL KW: 48.50 12&67 AMPS FED FROM: EXISTING 200 A. FEEDER 2 - #20 IN 2 " C. + 1 #30 GROUND E E El 3 1 ARCHITECT OF-PFCORD: MR. ARCN!TECT, ! I_C AA 2600230C MIG,IEL: ki DNDA LIC#AR94189- - 13899 BISCAYNE HOULFVARO SUITE 308 NORTH MIAMI BEACH, FLORIDA 33162 o: 305.600.4399 i nfo(a)_ m r-a rc h itect. co m D,awinge are subfect to rue, atlon or change es required by actual measurements, stantlam Industry practices in light of eristing svudural antl other conditions.. applicable building codes. and the like. These plans are and shall remain the property of MR. Architect LLC and shall not be sold or natura ced without prior written consent MR Architect LLC shall be notf dof any changes required by actual conditions prior to exeputlon of Zsold chances for any phase for construction. 2019. MR. Architect LLC � E O F 1: p� /11\ YIJ% ADDRESS: 390 N E 101 st Street Miami Shores, FL 33150 PROJECT. Bathroom Renovation OWNEWBUILDER: Martin SHEET TITLE: Electrical Sheet No. Description Date 1 Revision 1 8/29/19 Project Number: 31 2019 Date: 8/1 /19 Drawn By: MR Checked By: MR Scale: 1 If= 11-011 a ti LO c� rn 0 N CD K? 2 1 A B GENERAL PLUMBING NOTES: 1. A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code 2017 and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the plumbing work. C. ARRANGE AND PAY for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and/or improper workmanship for a minimum of one year for material and labor. E. ALL HORIZONTAL SANITARY PIPING 3" and larger shall slope at 1/8 inch per foot minimum, unless noted otherwise. per foot minimum, unless noted otherwise. All piping 2" and smaller shall slope at 1 /4"inch per foot minimum. 2. SHOP DRAWINGS: Contractor shall submit for approval, within 30 days of signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: water heaters, and plumbing fixtures. No work shall proceed without the approval of these submittals. 3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be furnished and installed by this contractor. Fixtures shall be complete with drains, traps, supplies and any other accessory required. 4. MATERIALS: A. PIPING: a. Soil, waste and vent, above ground: TYPE "K" OR "L": SEAMLESS HARD DRAWN OR ANNEALED, ASTM B88 TTPE DWV: SEAMLESS HARD DRAWN, ASTM B306 b. Domestic water: Copper pipe, Type L with sweat wrought copper fittings. Type "M" in concealed spaces is acceptable. Isolate piping from concrete with insulating material. d. P & T Relief and Drain Pan lines: DWV Copper pipe and ftgs. e. Domestic water supply assembly: Chrome finish tubing with angle shut off valves. 5. ALL AUTOMATIC ELECTRIC water heaters shall meet the standards of the latest state energy efficiency code. 6. PIPING TEST AND DISINFECTION& A. Test: All sanitary and domestic water supply piping shall be tested for leaks before piping is concealed or connected to equipment and plumbing fixtures. B. Disinfection: All domestic water piping shall be disinfected by introducing a solution of calcium hypochlorite of 50 parts per million of chloride and as per AWWA Standards. 7. VALVES: Domestic water valves shall be of bronze body, sweat ends. 8. HOSE BIBBS: Shall be 1/2 inch. rough brass construction with shut off valve and vacuum breaker. 9. ALL OUTDOORS FLOOR clean outs shall be terminated up to grade and shall be marked. 10. CONTRACTOR SHALL COORDINATE exact location of sanitary, storm and domestic water piping before starting any work. Notify Architect/Engineer of any deviations from design drawings. 11. CLEANOUTS: A. Wall: S. Finished Floor Josam 58890-15 Josam 56020-88-15 NOTES: C 1. ALL SHOWER HEADS SHALL BE OF THE ANTI -SCALD, PRESSURE BALANCE TYPE. 2. ALL FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE WATER CONSERVATION STANDARDS. 3. ALL PLUMBING FIXTURES, FIXTURES FITTING AND APPLIANCES FOR NEW OR SUBSTANTIALLY RESIDENTIAL STRUCTURES SHALL INCLUDE HIGH EFFICIENCY PLUMBING FIXTURES, FIXTURE FITTING AND APPLIANCES AS PROVIDE IN TABLE 604.4 OF SECTION 8-31 OF THE CODE OF MIAMI-DADE COUNTY. (W.0 1.28 gpf, LAV 0.5 gpm @ 60 psi INLET, SH HEAD 1.5 gpm, KIT FAUCETS 1.5 gpm @ 60 psi INLET.) 4. BATHTUB VALVES SHALL BE IN COMPLIANCE W/TEMPERATURE CONTROL REQUIREMENTS AS PER FBC P2713.3 5. ALL PLUMBING FIXTURES SHALL BE APPROVED PREVIOUSLY BY OWNER. COORDINATE BEFORE JOB COMMENCEMENT. PLUMBING FIXTURE CONNECTION SCHEDULE DESCRIPTION DRAIN WATER REMARKS COLD HOT WC WATER CLOSET (FLOOR MOUNTING.) DISCHARGE AT WALL 311 1/2" FLUSH TANK, 1.28 GPF WITH DISCHARGE AT WALL LAV LAVATORY (COUNTER TYPE) 1 1/2" 1/2" 1/2" PROVIDE 0.5 GPM FAUCET SH SHOWER (NOTE 1) 2" 3/4" 3/4" BASIN BY ARCH. (PROVIDE 1.5 GPM SHOWERHEAD) MAXIMUM DISTANCE FROM FIXTURES TRAP TO VENT SIZE OF TRAP (inches) SIZE OF FIXTURE DRAIN (inches) SLOPE (inch per foot) DISTANCE FROM TRAP (feet) 1 1A 1 1/4 1/4 31/2 1 1A 1 1/2 1/4 5 --- 11/2 1 1/2 1A 5 1 1/2 2 1A 6 2 2 1/4 6 3 3 1/8 10 4 4 1/8 12 For SI: 1 inch = 25.4 mm,1 foot = 304.8 mm, 1 inch per foot = 83.3 mm/m. NOTE: EACH FIXTURE TRAP SHALL HAVE A PROTECTING VENT LOCATED SO THAT THE SLOPE AND THE DEVELOPED LENGTH IN THE FIXTURE DRAIN FROM THE TRAP WEIR TO THE VENT FITTING ARE WITHIN THE REQUIREMENTS SET FORTH IN TABLE 906.1. FBCP TABLE 607.2.1 MINIMUM PIPE INSULATION FLUID DESIGN INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER OPERATING OR TUBE SIZE (IN.) TEMPERATURE RANGE, l CONDUCTIVITY MEAN TEMP. 1 TO 1-1/2 4 TO Btu " N RATING < 1 1-1/2 TO 4 < 8 8> DOMESTIC HOT WATER SYSTEMS > 105 0.22 - 0.285 100 0.5 0.5 1.0 1.0 1.0 Minimum pipe insulation Circulation hot water system shall be insulated in accordance with the requirements of table 607.2.1 FBCP NOTE: • ALL HORIZONTAL DRAIN PIPE 3" OR SMALLER SHALL BE SLOPED AT 1/4"/FT • ALL HORIZONTAL DRAIN PIPE 4" OR LARGER SHALL BE SLOPED AT 1/8"/FT. MIN. 0 7 NOTE: FLORIDA BUILDING CODE, PLUMBING SECTION 402 AND RESIDENTIAL SECTION P2701.1 THE PROVISIONS OF THE FLORIDA BUILDING CODE, PLUMBING AND RESIDENTIAL SECTIONS, SHALL APPLY TO ALL PLUMBING FIXTURES, FAUCETS AND FIXTURE FITTINGS AND SHALL BE CONSTRUCTED OF APPROVED MATERIALS, SHALL HAVE SMOOTH IMPERVIOUS SURFACES, AND SHALL CONFORM TO THE STANDARDS CITED IN THE CODE. Plumbing Plan - Detail View 3/4" = V-0" E pyt pp a=e rat �*W 209V i,lillari raqe Draw33 A :Required Breaker r40A Required mire iSAWO Heat -Achan er Stainjess Stewl Py'robection Zia Al x rtat r L!,_Aedto UL-499 .,,'rtted Lifetime DNNECT TO EXISTING 2" C WATER LINES )R LAV FAUCET VERTER NEW 1/2" H/C WATER LINES FOR SHOWER DIVERTER FOR OVERHEAD SHOWER AND WALL MOUNTED HAND-HELD NEW ECO 8 POINT OF USE WATER HEATER, RUN NEW HOT WATER LINES TO LAV AND SHOWER FROM UNIT CONNECT TO NEARBY C WATER LINE, V.I.F. BY PLUMBING CONTRACTOR n 3 ARCHITECT OF RECORD: MR. ARC,'-fITECT AA MIGU9_ PIONDA - - LIC. # AR_ b4189 - - 13899 BISCdfrdc HOULEvAP.D SJ,TE 308 NORTH MIAMI BEAGH- FLORIDA o: 305.600.4399 _ - infol Drawings are subbed to modification or change as required by actual measurements . standard Industry practices in light of existing structural and other ccrddions, applicable building codes and the like. There plans are and shell remain the property of MR. Architect, LLC and shall not be sold or rep"dupetl without poor w(eten consent MR. Architect LLC shall be notified of any changes required by actual conditions prior to execution of earl changes for any phase for construction. 2019, MR, Architect LLC rCOSIGN AND SEAL S` 214ACIO R/ 02 9 "o' R 04,1 9 ' �mG�iPj,• • � 7 , •,�Q. RFD ARGN� ADDRESS: 390 N E 101 st Street Miami Shores, FL 33150 PROJECT. Bathroom Renovation OWNER/BUILDER: Martin SHEET TITLE: Plumbing Details No. Description Date Project Number: 31 2019 Date: 8/1 /19 Drawn By: MR Checked By: MR Scale: 3/4" = 1'-0" Plllll,l,i,1 00 i d- 7t N 0'i rn T_ 0 LO Co C E