WS-04-20-706 (1)GENERAL NOTES This Signed and Sealed Design Applies to the Installation of New I" x PT Wood Bucks to Existing Substrates, As Shown. No Other Warranty, Express or Implied is Intended. This Design is Based on Information Provided to the Engineer by the Contractor. Contractor Shall Field -Verify Existing Conditions and Immediately Note Engineer of Any Discrepancies Herein. This Design Shall Not Be Valid if Existing Conditions Are Other Than as Shown Herein All Work Shall be Performed in Accordance with the Florida Building Code, 6th Ed. (2017) and Local Codes and Ordinances that May Apply. DESIGNNOTES Wind Loads Calculated in Accordance with FBC, 6th Ed. (2017) and ASCE 7-10: Vult=175 mph, Fxp=D %4 Tapcons in Single Staggered Row, 1 T o/c, 4" from Ends (Min. 13/4" Embedment, Min. 21/2 Edge Distance in Concrete) Existing Concrete—J 1" x PT or Grout Filled Wood Masonry Block NOTE: New Bucks Shall Extend Beyond the Interior Face of the Window Frame Such that Full Support of the Frame is Provided and Bucks Will Adequately Transfer the Loads Imposed upon Them to the Surrounding Structure, Meeting the Requirements of the FBC 6th Ed. (2017). All New PT Wood Shall Be Min. Grade 2. CATEGORY Engineerfng Services, Inc. 1600 S. Federal Highway. #207 Pompano Beach, FL 33062 (954) 784-6991 WOOD BUCKS FASTENING TO EXISTING SUBSTRATES Rozo Residence, j10151 NE 14 Ave, Miami Shores, FL Dwg: #AS R 1180125 1 Rev: 0 I By: ME Sheet: 1 of 1 Date: January 25, 2018 No Revisions Emma T. Mellinger, P.E. FL PE #50049 CA #25854 GENERAL NOTES This Signed and Sealed Design Applies to the Installation of New I "x PT Wood Bucks to Existing Substrates, As Shown. No Other Warranty, Express or Implied is Intended. This Design is Based on Information Provided to the Engineer by the Contractor. Contractor Shall Field -Verb Existing Conditions and Immediately Notes Engineer of Any Discrepancies Herein. This Design Shall Not Be Valid if Existing Conditions Are Other Than as Shown Herein All Work Shall be Performed in Accordance with the Florida Building Code, 6th Ed. (2017) and Local Codes and Ordinances that May Apply. DESIGN NOTES Wind Loads Calculated in Accordance with FBC, 6th Ed. (2017) and ASCE 7-10: V ul t=175 mph, Exp=D %4 Tapcons in Single Staggered Row, 12" o/c, 4" from Ends (Min. I Y4" Embedment, Min. 21/2 Edge Distance in Concrete) Existing Concreted 1" x PT or Grout Filled Wood Masonry Block NOTE: • New Bucks Shall Extend Beyond the Interior Face of the Window Frame Such that Full Support of the Frame is Provided and Bucks Will Adequately Transfer the Loads Imposed upon Them to the Surrounding Structure, Meeting the Requirements of the FBC 6th Ed. (2017). ■ All New PT Wood Shall Be Min. Grade 2. CATEGORY Engineering Services, Inc. 1600 S. Federal Highway. #207 Pompano Beach, FL 33062 (954) 784-6991 WOOD BUCKS FASTENING TO EXISTING SUBSTRATES Rozo Residence, 10151 NE 14 Ave, Miami Shores, FL Dwg�#AS R 1180125 I Rev: 0 I By: ME Sheet: 1 of 1 I Date: January 25, 2018 No. Revisions Emma T. Mellinger, P.E. FL PE #50049 CA #25854