RF-05-22-1319 UPLIFTLank Engineering LLC Testing & Engineering Services Certificate of Authorization # 33264 Tel: 954.245.8976; Fax: 954.301.7776 5230 NE 18th Avenue, Fort Lauderdale, FI 33334 Roof Tile Uplift Test Report Attention: Miami Shores Village, Building Department Test Date: 07/28/2022 Permit # RF05-22-1319 Property Address: 95 North East 96 th Street ,Miami Shores, FI f Roof Pitch: Type of Tile: Roof Area: 5 in 12 Roof Tile Per NOA 20.55 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro AH 160 Field Instrument: IMADA Force Gauge 0-100 Serial number: 243454 Client: Chase Roofing Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: 8.55 sq. 9 As per FBC 2020 Passed Field Area: 12.00 sq. 12 As per FBC 2020 Passed No. of Corner: 7 7 As per FBC 2020 Passed Ridge Areas: 180 PCs. 18 As per FBC 2020 Passed Important: These laboratory results can change due to future weather impacts and /or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. All tested locations were done using an Imada Force Gauge instrument with a minimum uplift load of 35lbs (for mortar or adhesive set tiles) and If applicable, for mechanically attached tiles a minimum static test uplift load of 80% of the Resistance Moment (Mr') or 80% of the Resistance Load (f') as listed in Product Approval (NOA) was applied. Please see attached a Roof Sketch for this project Cordially, Lank Engineering LLC. (NOA 21-1122.01) Andre Bigatao, PE Fla. Reg. No: 80977 b y f �,-�- r J D� 1 03 1 m z� m, l0 ; 0 rFLn S S 3� V 0 e V1 ' S -n r w• w_ w 00 V CD m p D w m6� Cn N CD-4 iN v W 0 u J J 01 N N N N N N N N N N N N S w r r r r r r r r r r r r R