RF-05-22-1319 UPLIFTLank Engineering LLC
Testing & Engineering Services
Certificate of Authorization # 33264
Tel: 954.245.8976; Fax: 954.301.7776
5230 NE 18th Avenue, Fort Lauderdale, FI 33334
Roof Tile Uplift Test Report
Attention: Miami Shores Village, Building Department
Test Date: 07/28/2022
Permit # RF05-22-1319
Property Address:
95 North East 96 th Street ,Miami Shores, FI f
Roof Pitch:
Type of Tile: Roof Area:
5 in 12
Roof Tile Per NOA
20.55 squares
Tile Attachment Method:
Two Component Polyurethane Foam Adhesive -Poly Pro AH 160
Field Instrument:
IMADA Force Gauge 0-100 Serial number: 243454
Client: Chase Roofing
Test Location
Total Number of Tests Field Uplift Pull Test Test results
Perimeter Area: 8.55 sq.
9 As per FBC 2020 Passed
Field Area: 12.00 sq.
12 As per FBC 2020 Passed
No. of Corner: 7
7 As per FBC 2020 Passed
Ridge Areas: 180 PCs.
18 As per FBC 2020 Passed
Important:
These laboratory results can change due to future weather impacts and /or unavoidable roof traffic. Therefore, this
report represents the TAS 106 results at the time of the test.
All tested locations were done using an Imada Force Gauge instrument with a minimum uplift load of 35lbs (for
mortar or adhesive set tiles) and If applicable, for mechanically attached tiles a minimum static test uplift load of 80%
of the Resistance Moment (Mr') or 80% of the Resistance Load (f') as listed in Product Approval (NOA) was applied.
Please see attached a Roof Sketch for this project
Cordially,
Lank Engineering LLC. (NOA 21-1122.01)
Andre Bigatao, PE
Fla. Reg. No: 80977