Loading...
RF-01-22-204 UPLIFTC. 11 TZ IL A II , I 1'l�ql C. r� July 20, 2022 Isaac's Roofing & Insulation 17225 South Dixie Highway, Unit 200 Miami, FL 33157 RE: TILE UPLIFT TEST PROJECT INFORMATION PROVIDED BY CLIENT: 9342 NE 9 Ave Miami Shores, Florida Parcel ID 11-3206-002-0050 Permit # Date inspected: June 20, 2022 Date completed by: July 16, 2022 Roofing Contractor: Isaac's Roofing & Insulation Carlab, Inc Project # 22-1329 Testing lab Certificate #: 19-0110.01 Dear Sirs, In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was estimated to be less than 1800 square feet, and the mean height of the roof is less than 45 feet above ground surface. The type of tile used for this project was reported to be Barcelona 900 Concrete /Clay Roof Tile. This tile was reported to have been foamed in place. At the time of this testing at least one test for every 100 square feet of roof tile in the perimeter area, one test for every 200 square feet of roof tile in the field area, and one test per corner were performed. The results for this report are valid at the time of testing only. Walking on the roof or any other type of physical disturbance may alter these results. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirement outlined in the above mentioned protocol. Attached please find a copy of our test report for your review. Should you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respec ly submitted, Sergio Labiste, PE 61733 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438 Test Test load (lbf) Test Status 109 35 Pass 110 35 Pass 111 35 Pass 112 35 Pass 113 35 Pass 114 35 Pass 115 35 Pass 116 35 Pass 117 35 Pass 118 35 Pass 119 35 Pass 120 35 Pass 121 35 Pass 122 35 Pass 123 35 Pass 124 35 Pass 125 35 Pass 126 35 Pass 127 35 Pass 128 35 Pass 129 35 Pass 130 35 Pass 131 35 Pass 132 35 Pass 133 35 Pass 134 35 Pass 135 35 Pass 136 35 Pass 137 35 Pass 138 35 Pass 139 35 Pass 140 35 Pass 141 35 Pass 142 35 Pass 143 35 Pass 144 35 Pass 145 35 Pass 146 35 Pass 147 35 Pass 148 35 Pass 149 35 Pass 150 35 Pass 151 35 Pass 152 35 Pass 153 35 Pass Test Test load (lbf) Test Status 154 35 Pass 155 35 Pass 156 35 Pass 157 35 Pass 158 35 Pass 159 35 Pass 160 35 Pass 161 35 Pass 162 35 Pass 163 35 Pass Test Test load Test (lbfl I Status 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438 N + \1 + + + + + + + + + + + + + + + + u + LEGEND + + FIELD TEST + + - PERIMETER TEST + + O CORNER TEST + + + + + + +F 55 R L A B, I N C. k., AND I�LILN�s CZ27UlrATB ar AUTF;OFTIATION 646 sw W Or. WMM ri, =0 aai., xs nM* PAM WS 2Y."M APPR❑X, ROOF TEST L❑CATI❑NS AND DIMENSI❑NS