WS-02-21-308 STATEMENT OF INSPECTIONMay 72, 2027
79552 SW 133►dAve, MMMI, FL 33177 * PHONES. (786) 443-1685 * FAX_- (305) 977-0240
GENML CONSTRUCTION a` PLANS * HOUSE& CONSTRUCTION INSPECTIONS
Statement oflnspection
Miami Shores Vi-I/age Building Department
70050 NE2nd Avenue
Miami Shores Florida 33138
Subject.- New Windows Installation atjohnnie Smith Residence
9726 NE 1st Avenue, Miami Shores Florida 33738
Re.- Permit No. WS-02-27-308 - Installed Windows Inspection
Dear Building Official -
Inspection of the above referenced item (or items) was completed at the subjectpremises May 72,
2027. Scope of this inspection includes mainly the nlateria , dimensions and installation method
used for relevant, in this report, building components and cladding.
Standard Procedures:
Normally, we are capable to verify visually most, or a# relevant materials and installation methods
used for the work to be inspected_ Where visual inspection is insufficient, as and where required we
use testing, spot check by exposure of the item in question, physical procedure, pictures,
equipment, practical experience, related paperwork, etc. These methods allow us to draw reasonable
conclusions.
INSPEC77ONME7HOD OL06Y USED IN THIS PROJECT -
Ksual observation and physical maneuvering were the methods used to conduct the required
inspections of the installed project work. Most or all work was exposed for visual observation. Work
material and installation were observed for conformance with approved plans & specifications and
the 2077Florida Building Code.
INSPECTION RESUL T -
List of Installed Windows:
• Twelve (12) Series WR771OA'°A/urninum Horizontal Roller Windows (20-0406.04)
D hive (5) Series `SH-7700A" Aluminum Single Hung Windows (NOA # 20-0401.17)
0 One (1) Series "CA-740" Outswing Aluminum Casement WIndows (NOA # 20-0402. 02)
• One (7) Series "PG7"Clipped ExtrudedAluminum Tube Mullion (NOA # 20-0406.03
NOTE New 7 nby PT wood bucks are installed as and where required at header, sill and
jambs of each window and/or door.
19552 SW 133b Ave, M/AM/, FL 33177 * PHONES.- (786) 443-1685 *FAX. (305) 971-0240
CENML CONSTRUCT/ON * PLANS * HOUSE & CONSTRUCTION INSPECTIONS
We verified that all material and installation meet the governing design criteria, the manufacturer
recommendation and the Miami Dade County NOA's included in the approved permit application and
drawings_ Window bucks are properly secured to the structural opening substrate with the specified
anchors sizes and quality. Anchors installation spacing, edge distance and embedment comply with
the minimum allow requirement. Maximum gap between structural substrate and windows framing
did not exceed the maximum allow0"sh/m. /n addition, heavy duty caulking was applied as
specified to bucks and at gaps between opening & window and/or door framing.
Consequently, I hereby attest to the best of my knowledge, belief and professional judgemen t, that
the inspected installation is sound and complies with the permit approved documentation and the
2017 FBC requirements.
Should you have any questions or need additional information, please contact me.
Respectfully Submitted, `0 E �0��
%
r No. stags i
ft�p
E-aerrera, RX,
,•
7HLS REPORT RELATES ONLY TO THESPECIFIED INSPECTED ITEMS, NOT TO THEENTIRECONSTRUCTION. IT CANONLYBEREPRODUCED IN FULL, AND ONLY
WITH OUR PERMISSION.