Loading...
CC-10-18-3286 REV PlansDESIGN TEAM: i 1�7_117 SEATING AREA Egress ell Hour to Details Door Schedule Key Note Description Door Hight and Width (Inch) Door Clear Opening (Inch) N.O.A / FL # D1 Sliding Door (Under Permit # WS-4-18-969) 120" x 288" 168" FL # 25959 D2 Double French Door (Under Permit # WS-4-18-969) 94 1/4" x 75 1/2" 67 1/2" FL # 150826.32 SL Side Lite (Under Permit # WS-4-18-969) 97 3/4" x 21" N/A FL # 27000 D3 Double Acting Door 84" x 36" 2'-10" Min N/A D4 Q Singel Interior Door (180 Degree) 84x 36" " 2'-10" Min N/A D5 Singel Interior Door 84" x 36" 2'-10" Min N/A D6 Singel Interior Door 84" x 36" 2'-10" Min N/A D7 Singel Door Existing To Remain 84" x 36" 2'-10" Min N/A D8 Singel Door Existing To Remain 84" x 36" 2'-10" Min N/A Note 1: All doors have a minimun door leaf > 34" (2'-10") with a clear opening > 32" (2'-8") Door In Means Egress: Note 2: Floor elevation on both sides of the door All door serving more than 100 Ocupants shall be provided shall not vary by more than 1/2". with panic hardware. Equipment Schedule Code Description Gas/Electrical BTU / KW Dimmensions A Espresso Machine Electrical 4300 W / 240V 34"Hx 24"Wx 24"D C Dishwasher Machine Under The Counter Electrical 1200 W / 120V 18.5"Hx 25"Wx 19.5"D D Dishwasher Machine Electrical 1750 W / 120V 34"Hx 24"Wx 24"D E Fryer Machine 4 Burners Gas 110,000 BTU 56"Hx 16"Wx 35"D G Ice Machine Electrical 4500 W / 240V 39"Hx 26"Wx 28"D H Worktop Refrigerator Electrical 2500 W / 120V 48"W J 2 Stove 4 Burners Gas 5000 BTU Each 36"Hx 24"Wx 25"D M Wood Grill N/A N/A 36"Hx48"Wx25"D N Convensional Oven (Double) Top/Bottom Gas 52"Hx 29"Wx 25"D o Under the counter Freezer Electrical 5000 W/24 V 0 53"Hx 29"Wx 25"D I IP102 10 Wall Leaend Existing 8" CMU Wall to Remain. New Partition Wall. Existing 1 hr fire rated partition wall to be upgraded to 2 Hours, and STC > 50 See Sheet A-2 U357 Design for Proposed Partition wall details. 1 511 SHOP DRAINING NOTES SHOP DRAWINGS AND SPECIFICATION SUBMITTALS TO INCLUDE BUT NOT LIMITED TO THE FOLLOWING: SUBMIT 4'SETS MINIMUM SIGNED 8 ;SEALED BY LIC. ENG. 111T ALL SPECS (FOR ARCHITECT PRIOR TO FABRICATION) ALLOW SUFFICIENT; TIME FOR PROCESSING „ _, r WO WEE SHOP DRAWINGS SH (T K,5) S.ALL 6C REVIEWED AND APPROVED BY CONTRACTOR AND ARCHITECT. SHOP DRAWINGS SUBMITTALS REJECTED SHALL BE RESUBMITTED SHOWING CORRECT TONS PRIOR TO FABRICATION. 8. COLOR > 1 ,, . SUBMIT SAMPLES ..ND U OR t CHART FtJFc FINISHES, SJi1Ml7 ROOFING BONE 10 YEARS (MATERIALS A T T z 4 A AND INSTALLATION), #�.EVATQitGUARAk.FFrcS.IF.APPi(CABL.., CONCRETE TEST AND DESIGN MIX MORTAR MIX AMET DESIGN. VATERIALS� INSTALLATION f FILYTORES DOORS -FRAMES DOOR TYPES,SPECIFICATIONS,INSTAj_1-AiTICNSANDH.ARDWARESCHED€1LES^LINOOWSANDGLAZING-DET.AILS AND SAMPLES ME TAT, WORK SUCH ASRAILINGS OA,FS ANDV,AIRSDRYNALI- MATFRIALSANDINSTAILAIION MECHANICAL 4,rHEATING AND 1 Tlt, IrN- A ERIAr�B AND FIX-, JR— SSPRINHLERS. METAL GUTTERS, GRAIN SPOUTS AJp10 VISUAL COMPONENTS, : ALARMS, KITCHEN EQUIPMENT CABINLTS-AS SHOIvra OPa INT;:RIOR DESIGN pRAI'dINOS FINISHES -AS SHDWN ON DRAWINGS: SAMPLES TO BE PROVIDED ON $I HE FOR AOR APPROVAL. ALL SUBCONTRACTORS "sFU1Ll. GUARANTEE THEIl21p'0RK (MATERIAL AND LABOR) FOR. AMINIMUM'r'FRIt?D OF ONE YEAR UNLESS01HERaVISF NOTED OR REQUIRED. PROPOSED FLOOR PLAN 1/411 = 1'-01, 0 1'IQ" S 1'-9" q+ 3 I / X.4 WE a I X I Existing CMU YAN L. SOLIS, P.E. Concrete wall To Remain ELECTRICAL ENGINEER 14245 S.W. 21 ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE:75423 " / / / /iV/l - I �G-OF GENERAL NOTES 1: THE CONTRACTORS AND ALL SUBCONTRACTORS SHALL UERIFYALL GRADES. LINES LEVELS CONDITIONS AND OINI;ENSIONS AT Tt{E JOB BITE AND AS SHOWN ON THE DRA'VJINGS. THEY SHALL REPORT IN t RITING ANY ERRORS, INGONSISIENCIPS OR OMISSIONS: ON 117E DRAWINGS TO FHE ARCHIIECTIENGINEER (ATE) BEFORE � 00111 JIENCING'NORK. THE CONI P,ACTOR AND ALL SUSCONrFAC'lORS SHALL. LAY OUI THEIR WDRK.FROM ESTABLISHED AEFERENCE POINTS AND ARE RESPONSIBLE FOR ALL LINES. ELEVATIONS, AND MEASUREMENTS IN CONNECTIO"tvdI �H 7HEIR NtORK: _ 2- CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS AND BE RESPONSIBLE FOR SAME_.. 3: THE CONTRACTOR IS RESPONSIBLE THAT ALL WORK AND MATERIALS SHALL BE IN COMPLIANCE WITH THE LATEST EDITION OF ALL APPLIC48LE LOCAL CODES, ORDINANCES; AND PERMIT PROCEDURES: 4. THE CONTRACTOR IS RESPONSIBLE FIND SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 33 OF THE FLORIDA BUILDING CODE. AND ALL LOCAL,. STATE AND FEDERAL LAWS. S: THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL+AORKAND MATERIALS FROM WEATHER DAMAGE. S. THE CONTRACTOR AGREES THAT HE WILL HOLD OWNER, ARCHIIE"1, ENGINEER ANC+QR ANY OF THEIR EMPLOYEES OR AGLNf S HARMLESS fW1111 ANY ALL DAMAGE AND CLAIh,iS'WHICH MAY ARISE BY REASON OF ANY'15GLIGENCE ON 7HF PART OF THE CONTRACTOR, ANY OF HIS ELBW17RACTCRS. NtATERIkS AND EQUIPMENT SUFP,lES ATMiD; U'R ANY OF THEIR lulf'L{)9"EE$ DR AGENTS, IN PERFORMANCE OF THIS CONTT'LACF AND N CASE APJY?1C71DN IS BROUGHT THEREFCFE AC1tl.'t'ST O7dNKR: ARCH[l LOT ENGINEERS ANWOR ANY OF THEIR EMPLOYEES OR AGENTS THEY REsEKVE THE RIGHT 10 DEFEND SUCH ACTION AND CHARGE ALL COST THEREOF I'D THE CONTRACTOR I. _O NOT SCALE DRAII7IN3 USE DIMENSION INDIC'ATFO ON DRAWINGS. (DIMENSIONS OF LARGER SCAF.E DRAINING AND DETAILS SHALL TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS. CON RAOTQR SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND VERIFY SAME IN FIELD- B. IN THE EVENT THEPE .ARE FOUND DISCREPANCIES ON SITE OR AMBIGUITIES 1N OR .OMISSION FROM THE CONTRACT DOCUMENTS. INCI-UDINO ALL FLANS AND SPECIFICATIONS PROVIDED, OR SHOULD BE ANY DOUBT AS TO THEIR MEANING AND INTENT, FHE ARCHITECT SMALL BE NOTIFIED IN WRnING BY THE GENERAL CONTRACTOR IN ORDER TO PROVIDE. CLARIFICATION. PRIOR TO THE CCMMFNGEF4FNT OF WORK. St. SOIL UNDER NEW BLABS TQ BE TERMITE TREATED AS PER F8C 181B.I.T. R. THE AR^CHIIECTILNGINEER SHALL NOT BE RESPONSIBLE FOR NOR HAVE CONTROL, OR CHARGE OF THE CONSTRUCTION MEANS. MFTRODS SEQUENCES OR PROCEDURES. OR POST SAFETY PRECAUTIONS AND PROGRAM:S:.. 11. ALL WOOD WITHIN WALL SHALL BE FIRE -TREATED. WOOD. CASING JAMBS AND TRIM SHALL BE STAIN. GRACE OR CLEAR UNLESS SPECIFIED C1)=1ERWfSE- 12. WHERE APPLICABLE, INSULATE MASONRY WALLS. EXTERIOR STUDS WALL$, AND ATTIC SPACE IN ACCORDANCE WITH THE ENERGY CODE CALCULATIONS. 13 ALL WINDOW AND DOOR SIZES ARE NOMINAL, VERIFY MANUFACTURER'S ACTUAL AND ROUGH OPENING DIMENSIONS. G-C. 70 EXPOSE ALL DOOR & WINDOW SURROUNDS (INTERIOR FACE) -TO CONCRETE €FLOCK PRIOR TO FINAL SIZING. 14 AL PERIMETER THRESHOtOS SHALL BE I i2" MAX, WII THE EXCEPTION OF SECONDARY SLIDING GLASS DOORS EXITING ONTO BALCONIES WITH IMPERVIOUS PIN. 15FIXED GLASS AND.OR OPERABLE WINDOW WITHIN 14' OF THE FINISH FLOOR SHALL BE SAFETY GLASS_ 16..ALL REQUIRED TESTS AND INSPECTIONS SHALT: BE PERFORMED BY OWNER 17: ALI Y A I PLASTER I a� ...ORAL AS R AND STUCCO SH,4LI.. RECEIVE TWO COATS OF PREMIUM QUALITY PA.IeVT: t�1006. SHALL, �� PAINTED OR STAINED. COLOR TO BE SELECTED BY OWNER;"ARCHITECT. 19. THE CONTRACTOR SHALL OBTAIN FROM ALL SUB CONTRACTORS THE SIZE AND LOCATION OPENINGS TO BE PROVIDED BY THEIR RESPECTIVE TRADE. THE GONI RACTORS SHALL BE RESPONSIBLE FOR COOROINANON. LOCATION, SIZEAND DcrAIL 1B. THE CONTRACTOR SHALL AS PER Mr NLIF- SPECS. NCA PROVIDE ALL SUPPLEMENTAL MATERIAL REQUIRED To PROPERLY INSTALL SUPPORT AND BRACE ALL ITEMS AND COMPONENTS WI I PI N THE WORK ZI' THE GENERAL CONTRACTOR GUARANTEES AND WARRANTS THAT ALL., V/ORK PERFORMED SHALL RL FREE FROM DuT:CrS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR AFTER THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY -ANY DEFECTS OR DAMAGE DISCOVERED DURING SAID PERIOD SHALL BE REPAIRED CAR REPLACEO AS,DIRECI ED IN WRITING BY'THE ARCHITECPO'W NE'R At N'O AODIFIONAL COSTS. 21. ALL INTERIOR FINISHES SHALL Bc.IN. ACCORDANCE WITH6HAPIERVIIOFTH,cFLORIDABUIL0NGGODE.1VnF.s.a33ASWEiLAaS.._ATE,IR#4. 22 CO'etFLETIONCONTRACTOR TO NOTIFY COMER ATTL OR ARCHITECT IN WRITING At LEAST ONE WEEK PRIOR TO FINAL NSFEC71CN_ FINAL DISBURSEMENT TO CC4'RACTCRSHAIi NO1'LtFMADE UNiILOWNERS PUNCH LIST HAS sJELNSAIISFILUCONTRACTORTGPROVIDE OI^tNERiVJIHAN[iEN GLARANHFP ONALI,EQUIPMENT. CONTR,ACTORATCOMP_71ONI OFWORK SHALL REMOVE FRO M7HEFREMIBES.ALLRUBBISTi:SPACEIMPLEMENTS,EGUIPMENTA.NDSURPLUS MAT ERIALS,AND LEAVE THE PRCJ EC* .B RCOP,I CLEAN':: . 23. CONT:RAGTOR SMALL SUBMIT SHOP DRAWINGS AND ALL REQUIRED NOTICES OF APPROVAL FOR ALL CUSTOM FABRICATED WORK_ CONTRACTOR SHALL REVIEW APPROVE ALL SUa"IT?A(SISHOP DRAlVING FR10R 10 SUEMIT I ING FOR ARCHITECTS RLVIFV,': 24. G C, TO COORD. WITH OWNER ACCESS TO SITE AND SECURITYISSUE5 26. rMALL PREFABRICATEDLCUIPMENTCON IRACIORFAUSTVERIFY EXACT 'DIA4ENSIONS&MOUNTINOIINS1ALLATIONPRIOR ',0 INSTALLING. PROVIDE ALL MATERIALS& LABOR NECESSARY FOR THE INSTrALLATION. AS PER MANUR SPECS. ALL CONTRACT DOCUMENTS. Existing CMU Concrete Wall To Remain &i L. S Ot/s PE 75423 I Ck u/ONA`-�� YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS r I PROJECT: Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE 1� ev 5/27/2019 20 ev 6/18/2019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: Bar Counter Top Details. Travel Distance From Bar Bar Opening Detail SHEET No: Aiiiiiiiiiiiii 1 C:\Users\Yan\Dropbox\2018\9801-9845 NE 2nd Ave Miami Shores FL 33138\New Restaurant\Revised Bar\Floor Plan Rev Bar.dwg, 7/8/2019 9:16:49 AM, AutoCAD PDF (General Documentation).pc3 DESIGN TEAM: door Schedule Key Note Description I Door Night and Width (Inch) Door Clear Opening (Inch) N.O.A / FL # D1 Sliding Door (Under Permit # WS-4-18-969) 120" x 288" 168" FL # 25959 D2 Double French Door (Under Permit # WS-4-18-969) 94. 1/4" x 75 1/2" 67 1/2" FL # 150826.32 SL O Side Lite (Under Permit # WS-4-18-969) 97 3/4" x 21" N/A FL # 27000 I D3 Double Acting Door 84" x i Z-10" Min N/A — OD4 Singel el Interior Door (180 Degree) e ) 84x 36 2-10„ Min N/A D5 Singel Interior Door 84" x 36" Z-10" Min N/A S D6 Singel Interior Door — 84" x 36" 2'-10" Min N/A J D7 Singel Door Existing To Remain 84" x 36" Z-10" Min N/A D8 Singel Door Existing To Remain 84"x 36" Z-10" Min N/A Note 1: All doors have a minimun door leaf> 34" (2'-10")with aclear opening >32"(2-8") Door In Means Egress: Note 2: Floor elevation on both sides of the door All door serving more than 100 Ocupants shall be provided shall not vary by more than 1/2". with panic hardware. Equipment Schedule Code Description Gas/Electrical BTU / KW Dimmensions A Espresso Machine Electrical 4300 W / 240V 34"Hx 24"Wx 24"D C Dishwasher Machine Under The Counter Electrical 1200 W / 120V 18.5"Hx 25"Wx 19.5"D D Dishwasher Machine Electrical 1750 W / 120V 34"Hx 24"Wx 24"D E Fryer Machine 4 Burners Gas I10,000 BTU 56"Hx 16"Wx 35"D G Ice Machine Electrical 4500 W / 240V 39"Hx 26"Wx 28"D H -Worktop Refrigerator Electrical 2500 W / 120V 48"W J 2 Stove 4 Burners Gas 5000 BTU Each 36"Hx 24"Wx 25"D M Wood Grill N/A N/A 36"Hx48"Wx25"D N Conversional Oven (Double) Top/Bottom Gas 52"Hx 29"Wx 25"D o Under the counter Freezer Electrical 5000 W/240V 53"Hx 29"Wx 25"D Wall Le en`d Existing 8" CMU Wall to Remain, New Partition Wail. Existing l hr fire rated partition wall to be upgraded to 2 Hours, and SSTC > 50 See Sheet A-2 U357 Design for Propcsed Partition wall details. SHOP DRAWING � © WING NOTES SHOP DRAWINGS AND SPECIFICATION SUBMITTALS TO INCLUDE BUT NOT LIMITED TO THE FOLLOWING: SUBMIT 4 SETS MINIMUM SIGNED & SEALED BY i IC. ENG bS ALL SPECS (FOR ARCHITECT APPROVAL PRIOR TO FABRICATION) ALLOW SUFFICIENT TIME FOR PROCESSING (n4'O WEEKS). SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY CONTRACTOR AND ARCHITECT. SHOP DRAWINGS SUBMITTALS REJECTED SHAL L BE RESUBMITTED SHOWING CORRECTIONS PRIOR TO FABRICATION - SUBMIT SAMPLE S AND COLOR CHART FOR FINISHES, SUBMIT ROOFING BOND 10 YEARS' (MATERIALS AND INSTALLATION) ELEVATOR GUARANTEES IF APPLICABLE, CONCRETE TEST AND DESIGN MIX MORTAR MIX AND DESIGN. MATERIALS INSTALLATION+FIXTURES DOORS -FRAMES DOOR TYPES, SPECIFICATIONS, INSTALLATIONS AND HARDWARE SCHEDULEWiNDOWSANDGLAZING- OETAILSANDS.AMPLES METAL WORK SUCH AS RAIL INGS GATFS, AND STAIRS DRYWALL - MATERIALS AND INSTALLATION MECHANICAL A'C HEATING AND VENTILA7ION MATERIALS AND FIXTURES SPRINKLERS, METAL GUTTERS, DRAIN SPOUTS AUDIO VISUAL COMPONENTS, ALARMS. KITCHEN EQUIPMENT, CAENErS -AssesOWN ON IN'eRIOR DESIGN DRAWIN GS S FINISHES - AS SHOWN ON DRAWINGS.. SAMPLES TO BE PROVIDED ON SITE FOR AOR APPROVAL. ALL SUBCONTRACTORS SHALL GUARANTEE THEIR WORK (MATERIAL AND LABOR) FOR A MINIMUM PERIOD OF 015E YEAR UNLESS OTHERWISE NOTED OR REQUIRED. New Restaurant Floor P[l I ,fin=5r 1. THE CONTRACTORS AND ALL SUBCONTRACTORS SHALL VERIFY ALL GRADES, LINES. LEVELS, CONDITIONS AND Dl L '.TOWS 4 '. ,,OB Si _ AND AS a 06N ON THE CRArVINGS e� THEY SHALL REP u + ^n ORT IN WRITINv ANY ERRORS IN,.ONSISIEMCI_S, OR Ohl�olONS •ON THE C+RA, I, S ;": H .'•ilILLN_INLE•c w 6L'ORE COMMENCING WORK. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL LAY ,7UT THkIF' NrQRK.`Sd?rot ESTABLISFc 3 , ° E; i Ir, . N> S (E RE: ..115184E FOR ALL LINES, ELEVATIONS, AND MEASUREMENTS IN CONNECTION WITH THEIR WORK. 2_ CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS .AND BE RESPONSIBLE FOR SAME 3. THE CONTRACTOR IS RESPONSIBLE THAT ALL WORK AND MATERIALS SIi4l, BE IN Q:)LIPLIAaN.'E WITH THE LATEar EDI ION' ALL APPLICABLE LOCAL CODES, ORDINANCES. AND PERMIT PROCEDURES. 4. THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH T E REOUIREMEN�' OF "IdAPTE4 33 OF THE FLOW')A BUILDING `. 1E AND rill.'- LOC,',.L, STATE AND FEDERAL LAWS. - 5 THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL WORK AND MATeRiALS FPOM WEATHER DAMAGE. n, THE CONTRACTOR AGREES THAT HE WILL HOLD OWNER. ARCHITECT, ENGINEER ANVIOR ANY OF THEIR EMPLOYEES OP AGENTS t ;'I:LSS FROIA ANY .ALL DAMAGE AND CLAIMS v1HICH.PAAY AR ISE BY REASON OF ANY NEGLIGENCE ON THE PART OF THE CONTRACTOR. ANY OF HIS Si16CONTFcA47 ; ! MATERIAL?, AND EQUIPMENT SUPPLIES AND.rOR. ANY OF THEIR EMPLOYEES OR AGENTS, IN PERFORMANCE OF THIS CONTRACT AND IN CASE ANY ACTION IS BROUG'r HERFF°CR...AGAINST OWNER, ARCHITECT, ENGINEERS AND'OR ANY OF THEIR EMPLOYEES OR AGENTS THEY RESER\' i THE RIGHT IC DEFEND SUCH ACTION AND CHl ALL O,9- THEREOF TO THE CONTRACTOR- ,. DO NOT SCALE DRAWING: USE DIMENSION INDICATED ON DRAWINGS DIMENSIONS 01 ARG+FT SCALE DRAWING AND DETAILS 1 t L TAK� PRECEDENCE OVER SMALLER SCALE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DIMENSIONS AND VERIFk SAME IN FIELD'. S. IN THE EVENT THERE ARE FOUNT} DISCREPANCIES ON SITE OR AMBIGUITIES IN OR OMISSION FRDM, THE CONTRACT DOCUMENT NCLOOING ALL FLANS AND SPECIFICATIONS PROVIDED, OR. SHOULD BE ANY DOUBT AS 10 THEIR MEANING AND INTENT,. THE ARCHITECT SHALL BE NOTIFIED I +R!I NG BY THE GENERAL CONTRACTOR IN ORDER TO PROVIDE CLARIFICATION. PRIOR TO THE COMMENCEMENT OF V ORK. 9. SOIL UNDER NEW SLABS 10 BE TERMITE TREATED AS PER FSC 1"''. THE ARCHITECT,ENGINEER SHALL NOT BF RESPONSIBLE FOR, NOR HAVE CONIROI., OR CHARGE OF THE CONSTRUCT'ON MEANS, ' "FOES$,. SEQUENCES OR PROCEDURES OR FOR SAFETY PRECAUTIONS AND PROGRAMS. 11. ALL WOOD '14ITHIN WALL SHALL BE FIRE -TREATED WOOD CAS!NG, „IAMBS AND TRIM SHALL BE STAIN GRADE OR C'-EAR. UNLESS SPECIFIED s I, : R'xNIS£. 12- WHERE APPLICABLE, INSULATE MASONRY WALLS. EXTERIOR STUDS WAILS, AND AT T IC SPACE IN Ai. ORDA,N'r,E WITH THE ENERGY CODE CA LQ,-ATIONS. 13. ALL WINDOW AND DOOR SIZES ARE NOMINAL VERIFY MANUFACTURER'S ACTUAL AND ROUG'k OPE%ING DIMENSIONS. C?,:;. TO EXPCE,'F'VLL DOOR & W1NDJOW SURROUNDS (INTERIOR FACE) TO CONCRETE BLOCK FRIOR TO FINAL SIZING- 14 ALL PERIMETER THRESHOLDS ALL BE 42MAx. r THE EXCEPTION OF SECONDARY SLIDING GLASS DOORS EXITING ONTO BALCONIES ih IT1,' i� '. RVIOUS PIN. 15 FIXED GLASS AND?OR OPERABLE WINDOW WI7HIN 24 OF THE FINISH FLOOR SHALL BE SAFETY GLASS. 15. ALL REQUIRED TESTS AND INSPECTIONS SHALL BE PERFORMED BY OWNER- 17. ALL. DRYWALL, PLASTER AND STUCCO SHALL RECEIVE TWO COATS OF PREMIUM QUALITY PAINT. WOOD SHALL BE PAINTED OR STAINED.. COLOR. TO L', SEL,:CTED BY ^':!NERIARCHITECT. 19. THE CONTRACTOR SHALL OBTAINI. FROM ALL SUB CONTRACTORS THE SIZE AND LOCATION OPENINGS TO 8E PROVIDED BY THEIR RE5PEC7i`-' TRADE. THE CONTRACTORS SHALL BE RESPONSIBLE FOR COORDINATION. LOCAIION, SIZE AND DETAIL 19. THE CONTRACTOR SHALL AS PER MofANUF_ SPECS N04 PROVIDE ALL SUPPLEMENTAL MATERIAL REQUIRED TO PROPERLY INSTALL, SUPPORT AND f ALL AGE 4 L ITEMS AND COT,IP4NEN'rSYdITHIN THE WORK , 2c^. THE GENERAL CONTRACTOR G:UARANTEES AND;„+ARRANI5 THAT ALL WORK PERFORMED SHALL 8E FREE €ROt"i D+ reGTS IN MATERIAL AND WC ,-:a.ANSMIPFOR A. PERIOD , I DOF ONE E YEAR AFTER�. THE ISSUANCE OF THE CERTIFICATE OF OCCJPANCY. ANY DEFECTS OR DAMAGE DISCOVERED DURING SAID PERIOD SHl+ .1. 3E REPAIRED OR REPLACED AS DIRECTED IN WRITING BY THE ARCIFFIECTIOWNER,Ar NO ADDITIONAL COSTS. 21.ALL INT r. Te ERIORFINISHEssHALLBEINACCORCANCE1AliHCHAPR..RVIIIOFTHEFLORIDABUNJINGCODE.TABLESu+s.ASsT,ATEDINi±4. 22. CCMPLETION.CONTRACTOR TO NOTIFY OWNER ANDOR ARCHITECT IN WRITING AT , EAST GIVE WEEK PRIOR 3 F NA-L INSPECTION FIT•' I O!SSUIRSEIa'EN+ TO CONTRACTOR SHALL NOT BE BLADE UNTIL OWNERS PUNCH t.ISr HAS BEEN SATISFIED.001 'RACTOR "TG -'�iOVIDE OWNO :a ,H WRI F,EN GUARAFf (N ALL LQUIPMEN"= CONTRACTOR AT COMPLETION OF WORK SHALL REMOVE FROM THE PREMISES ALL RUBBIS 1 SPACE'IMPI PMENTS,EQUIPVSG j PROJECT "BROOM CLEAN". ,..AND SURPLUS MA +':15, AND LEAVE THE CONTRACTOR SHALL SUBMIT SHOP DRRt4 ;,AND ALL 'Rf 0,UIRED N * :ES r PRO4.I. PUR ALL LUS Oi',.'. FABRICATED W1 :r . CONTRACTOR SHALT 0 Wi'APPROVE Ai t 3IJ9MITfALSiSHOP DRA'AIR . , 'C R Tv _ . 4' 1 TING FOR HI C I C VIEW Y� C ORC.Vv11- JWNCr.ACCESSTOSITE AND SECURITY ,SSUES. 1 a,ALL '.4- BR ATEDEOUIPMENTCON IFACTOR TAUVEHIFYEXACI'0'NSTk FROVIDFAI,-MATERI'LS& i ABORNECFSSARYF�)RrHFINSTALLATION-ASPFRMANUF. nECS-ALLCONIR 1i^u ,. Temporary Propane Gas Tank voi D on v f-01 ,arry A: D r�; EP MlAMI DADS' CA, vf1 i'';,ic t1..� ARTNiENT BLDG Pdf�'.1iT r! EA RM ._.� R lA.z.. FIRE Sti R "—"10N-_.WATER MAIN EKT. DAT�'JI/;Y 3 9 20 )9 YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 s i PE 75423 f p�...oS/Z71 =:Ffs.ONA`��G YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITYAPPROVAL STAMPS 000 0 0 Dose ® o oe a o®eo u 0 - ooeamo a Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE L Rev t 5/2712019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: n: t New Bar arec layout New Electrical Panels SHEET No: DESIGN TEAM: ELECTRICAL LEGEND PSE IHNE THAT APPLY) a- 20A, 120V SINGLE RECEPTACLE. 20 A., 120., V., DUPLEX gr RECEPTACLE,GROUNDING TYPE, U.O.N. MOUNTED 16'AFT. OR AS DIRECTED BY ARCHITECT. 20A, 120V GFI DUPLEX RECEPTACLE. 20A, QDUPLEX RECEPTACLE @ 18"AFF, U.O.N. ®�I FLOOR MOUNTED 20A, QDUPLEX RECEPTACLE ®20A, 120V CEILING MOUNTED RECEPTACLE. ® 208V SPECIAL PURPOSE RECEPTACLE. tH LIGHTING SWITCH@48"APR iN &WAY LIGHTING SWITCH @48"AFF. or SWITCH WITH OCCUPANCY SENSOR. m PUSH BUTTON. SAFETY DISCONNECT SWITCH. ELECTRIC PANEL. m CEILING AND WALL JUNCTION BOX. EXHAUST FAN. TV OUTLET. Q PHONE DATA OUTLET (AS PER OWNER REQUEST). ® 2'x 4' FLUORESCENT FIXTURE. FLUORESCENT FIXTURE LAY -IN EMERGENCY. ® 8"x 4' FLUORESCENT FIXTURE. '''0 RECESSED MOUNTED FIXTURE. I-{T} WALL/PEDESTAL MOUNTED LIGHT. CEILINGIPENDANT LIGHT. t� WALL PACK LIGHT. i� EMERGENCY LIGHT WBATTERY BACK UP AND CONNECTED AHEAD OF ANY SWITCH. EXIT LIGHT WIBATTERY BACK UP AND ® CONNECTED AHEAD OF ANY SWITCH. (SHALL NO EXCEED 5 WAIT PER SIDE c = ABOVE THE COUNTER. WP= WEATHERPROOF. VP= VAPOR PROOF. 16"0 S/A METAL DUCT Expoesd 16" Steel Joist @ 4811 O.0 I 1 I I o a) Ud I I ILu I co M .�l 24"0 S/A 24"0 S/A METAL DUCT 1 S/A1 I METAL DUCT 16"0 S/A METAL DUCT R.T.0 I} a \ s N N 30CFM e I'I SEATING AREA m a SEATING AREA m 0 Exposed Ceiling Height: 1- 1 V-3" from Finish floor to underside of exposed steel joist. 2- 12'-7" from Finish floor to underside of existing roof deck 3- 8'-6" Min from Finish floor to underside of A/C Ductwork Existing Plaster Ceiling on 16" Steel Joist @ 4811 O.0 d II rn0 Q U) J \ UL >I �0 / I O- 7 dl / I QoW KITCtIEN j o W of 00(D o `) Y U I I I R.T.0 14"x1Z q #2 \ t600 CFM 1 \I I S. a Area I PREP. AJEA \ 1 — A-45 TO CONTACTOR / T IN SUPPLY ROOM 14"x12' 12"JCS" 12x10" 150CFM® 1600 CFM 150GFM® 300 C M®11 6 "0 I PANEL womy C Mens Y k' I D$10:0 CFM �^� — Storage NEL o o. L___I Existing Plaster Ceiling Height: 1 V-0" from Finish floor to existing plaster ceiling. 6"0 E/A WALL CAP (PROVIDE CORROSION RESISTANT SCREEN AT TERMINATION POINT) 6"0 E/A WALL CAP (PROVIDE CORROSION RESISTANT SCREEN AT TERMINATION POINT) Reflected Ceiling Plan SCALE: 1 /4" = V-0" YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE:75423 YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS • •uu• Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave #204 Miami FL 33137 MANAGMENT: # REVISIONS DATE ev 5/27/2019 ev 6/18/2019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: Bar Counter Top Details, Travel Distance From Bar Bar Opening Detail SHEET No: AiIiIIIIII,4 is C A[ lgPrc.� - nCL o . i . . , v . .. . , r al uocumentation). DESIGN TEAM: ELECTRICAL LEGEND (USE THOM THAT APPLY) e- 20A, 120V SINGLE RECEPTACLE. 20A„ 120., V., DUPLEX gr RECEPTACLE,GROUNDING TYPE, U.O.N. MOUNTED 18" A. FP. OR AS DIRECTED BY ARCHITECT. 20A, 120V GFI DUPLEX RECEPTACLE. 20A, QDUPLEX RECEPTACLE 018"AFF, U.O.N. FLOOR MOUNTED ® 20A, QDUPLEX RECEPTACLE ®20A, 120V CEILING MOUNTED RECEPTACLE. ® 208V SPECIAL PURPOSE RECEPTACLE, 10 LIGHTING SWITCH ®48"AFF. 3-WAY LIGHTING SWITCH @ 48"AFF. SWITCH WITH OCCUPANCY SENSOR. m PUSHBUTTON. pl SAFETY DISCONNECT SWITCH. IO ELECTRIC PANEL. m CEILING AND WALL JUNCTION BOX. EXHAUST FAN. TV OUTLET. Q PHONE DATA OUTLET (AS PER OWNER REQUEST). 2'x 4'FLUORESCENT FIXTURE. [A2'x 4'FLUORESCENT FIXTURE LAY -IN EMERGENCY. ® 8'k 4'FLUORESCENT FIXTURE. O RECESSED MOUNTED FIXTURE. H(T} WALL /PEDESTAL MOUNTED LIGHT. r{'} CEILINGIPENDANT LIGHT. Tg WALL PACK LIGHT. EMERGENCY LIGHT W/BATTERY BACK UP AND CONNECTED AHEAD OF ANY SWITCH, EXIT LIGHT WIBATTERY BACK UP AND ® CONNECTED AHEAD OF ANY SWITCH. (SHALL NO EXCEED 5 WATT PER SIDE; c = ABOVE THE COUNTER. WP= WEATHERPROOF. VP = VAPOR PROOF. 0 Expoesd 16" Steel Joist @ Existing Plaster Ceiling on 4811 O.0 16" Steel'Joist @,48" O.0 50'-2" 30'-6" Floor surface \ / 11 __.� / on both sides ` I — of the door no — — _ _ — — _ _ — /_— — --— —— I I zoo \ \ a U) 0-I I Stor e Area QO� I l BAR ` l l l I I I I KITCfIEN I o 0 0l PREP. AREA L- 4 z LU Q / / I 1 1 / I / 1 /. /. v) I / / \ . _ A-45 / @ m �( I IN CONTACTOR / IN SUPPLY ROOM 14"x12" ' 14"x12" 12"x10" I R.T.0 A 12"X8"Q 12"X8" 1. / SD 16" O S/A I #2 600 CFM 15� FMB 600 CFM 15 .300 CFM. �— METAL DUCT' — _ —I— — Fit16"0 S/A 24"0 S/A S/A 24"O S/A T I S/A s' berg a'sA oucT ts" FB rgy pu T / METAL DUCT METAL DUCT I METAL DUCT / 0 0 0 0 Sa o 00 00 �.� R .0 RA 1 0 \ fPANEL "0 A _ WOM a 1 s a < 30CFM PWV — _ Mens _ A 100 CFM a SEATING AREA m SEATING AREA e yy �I Storage f PANEL O 0 '\ yO O OEQui CIos tnt2IX >>-a Exposed Ceiling Height: 1- 11'-3" from Finish floor to underside of exposed steel joist. 2- 12'-7" from Finish floor to underside of existing roof deck 3- 8'-6" Min from Finish floor to underside of A/C Ductwork Existing Plaster Ceiling Height: 1 V-0" from Finish floor to existing plaster ceiling. 6" 0 E/A WALL CAP (PROVIDE CORROSION RESISTANT SCREEN AT TERMINATION POINT) 6" 0 E/A WALL CAP (PROVIDE CORROSION RESISTANT SCREEN AT TERMINATION POINT) �! Oily or damps Jilof-t full E Ls Is t"/ i rl''r';ARi"MENT DI7r nrL' °T_....._._.. WA'U%V1 14 LJtT._-__ ' eail� VOF4 V: .i x Reflected Ceiling Plan SCALE: 1/4" = V-0" YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 01� OF F(�'' PY L. PE 75423 c . \_ r NAt- 1 YAN L SOLIS PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS . s a0®aaa a PROJECT: Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 .MANAGM ENT: # REVISIONS DATE 10 ev 5/27/2019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: New Bar area layout New Electrical Panels SHEET No: A-4 2 DESIGN TEAM: 2HR Fire Rated CMU Concrete Wall To Remain 1'-4 2 +�+- +1+ + + + + +I+ YAN L. SOLIS, P.E. I 14245 S.W. 21ST TERRACE SEA + Storage Area °Z MIAMI, FL $3175 + I + + I + I + I+ PH: (305 484- 596 BAR a TIT N EP. + + + +Existing CMU SEAL: + + + + Concrete Wail To I+++ I+ Remain I a + O F Ft ��. O 2 SE TING.AREA + + + +PN L'S o [77 D PE 7,5p42/3��p 42 To Exit � If t�fG NA1-E, r a ❑ ❑ YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE& CITY APPROVAL STAMPS Ft Travel Dstance 54 Ft Common Path of Travel/ 56 FtCommn LLLLLLLLL L LL - • •s ••e•e• s ••••s• 0 a• ••i •m••i• - - LL- - - - - - La O0 0 a I+ + Existing CMU Concrete Wall To L O Remain - - I+ A.LL orl�e + + O~S Mans + }• •�• •••••• • •••••••.••••.••••• 5� 5' I+ +ory+ +I .. .....: L L SEATING AREA Storaage Egress n 60FtTravefDistance + + t + + ••"••• L_ L_ a SAT/ G AREAS ens —4 LLLL L- L_ L- L_ L_ L- L- L_ a 5 Egress ' � 35 Ft To Exit Door L- L_ L- L- ------� 2-36" Swing Doors 68"/0.2 = 340 Ocupants Counter Detail N.T.S " S.S Drink Rail Manuf. ,rch Hardware, Inc lodel: DR459-4 Or pproved Equal C: Existing i Hour Rated Fire Wall To be upgrated to 2 Hour Details Occupant Load Calculation (NFPA) As per Table 7.3.2,1 Life Safety Code Bar Area 70 Sq Ft / 5 14 Kitchen/Staff Area 607 Sq Ft / 100 6.07 Storage Area 138SgFt/300 0.46 Waiting Area 100 Sq Ft / 5 20 q Total Occupant Load = 160 Y Y Y Y Y Y Y Y Y Y Y Total Occupant Summary Interior 120 Exterior 30 Total 150 i V Class of Rehabilitation: Change of use or Occupancy Classification. (43.7.2.2) Door In Means Egress: All door serving more than 100 Ocupants shall be provided with panic hardware. Interior wall and ceiling finishes shall be classified in accordance with ASTM E=84. Such interior finish material shall be grouped in the following classes in accordance with their flame spread and smoke developed indexes. Class A: Flame Spread 0-25; Smoke Developed 0-450 Class B: Flame Spread 26-75; Smoke Developed 0-450 Class C; Flame Spread 76-200; Smoke Developed 0-450 Interior Finishes Shall comply with NFPC 6th Eddition 10.2.2. And FBC Chapter 8. Florida Fire Prevention Code Occupancy Classification: Florida Fire Prevention Code, 6th Edition (12.2.5.1.2) Assembly Occupancy 3.3.188.2 Assembly use for a Gathering of 50 or more persons for deliberation, worship, entertainment, eating, drinking, amusement, awaiting transportation or similar uses. L. Egress Requirements Not Sprinklered, no Fire Alarm system Common Path Limit = 20 Ft if more than 50 Persons, 75 Ft if less than 50 Persons Dead —End Limit = 20 Feet. Travel Distance Limit = 200 Feet Min Number of Mean Of Egress: 2 Flame Spread Exits are not protected by a sprinkler system: Class B/ll Flame Spread 26-75: 0-450 smoke development. It shall be the responsibility of the General Contractor to submit rating information to thelocal building official if so requested. 12.7.4.1 Fabrics & films used for decorative purposes, all draperies and curtains, and similar furnishing shall be in accordance with the provisions of NFPA 10.3.1 Legend Existing 8" CMU Wall to Remain. Exit/Emergency Light. ---� Common Path of Travel. sD Smoke Detector. New Partition Wall. ® Existing 1 hour FireRated Partition Wall. Note: Additional Exit and Emergency Lights and other life safety components may be required by the field fire Inspector at the time of the fire Final inspection. 36" Swing Doors 34'70.2 = 170 Ocupants mLIFE SAFETY FLOOR PLAN Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE 10 ev 5/27/2019 ev 6/18/2019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: Bar Counter Top Details. Travel Distance From Bar Bar Opening Detail SHEET No: LS-1 C:\Users an -yt54+:fit Lna Ave iviiaml aurant\Kevis an , u o enera o- ocume DESIGN TEAM: Existing 2HR Fire Rated CMU Concrete Wall To Remain 1'-4" -/4�4 .. .. ge Floor surface 0 - - on both sides of the door no �� more than 1/2" SEA BAR D a D a D a a as a SE .TING AREA L- L_ L- L- L- L_ L_ L- L- L- L_ L- L_ L_L-L_LILLLLLL L Egress L— L— L— \ L_ L_ L T L— L— L / LLLL L_ L_ L- L- L- L_ L- L- j' L_ L_ L_ L_ L_ L- L- L_ 2-36" Swing Doors 68"/0.2 = 340 Ocupants '_j al. a 63 Ft Travel Distance 54 Ft Common Path of Travel < o 0 0 56 Fa Comm Path �Travelg o o. o a a a as E. 0 60 Ft Travel Distance S8ATING AREA Occupant Load Calculation (NFPA) As per Table 7.3.2.1 Life Safety Code Bar Area 70 Sq Ft / 5 14 Kitchen/Staff Area 607 Sq Ft / 100 6.07 + + + ++ Storage Area 138 Sq Ft / 300 0.46 1 q Waiting Area 100 Sq Ft / 5 20 oo. q Class of Rehabilitation: Change of _use or Occupancy Classification. (43.7,2.2) Door In Means Egress: All door serving more than 100 Ocupants shall be provided with panic hardware. Interior wall and ceiling finishes shall be classified in accordance with ASTM E=84. Such interior finish material shall be grouped in the following classes in accordance with their flame spread and smoke developed indexes. Class A: Flame Spread 0-25; Smoke Developed 0-450 Class B: Flame Spread 26-75; Smoke Developed 0-450 Class C: Flame Spread 76-200; Smoke Developed 0-450 Interior Finishes Shall comply with NFPC 6th Eddition 10.2.2. And FBC Chapter 8. Existing 1 Hour Rated Fire Wall To be upgrated to 2 Hour Details + + + + + + + o h + Storage Area + + + + + +++�+ + + + + Existing CMU Concrete Wall To + + + + Remain + + + + 42 O O t _J + + Existing CMU Concrete Wall To +F + + + + Remain Office + + + S Mans + + + + I+ + +Pry + + +I +StoTge + + ens —++ Florida Fire Prevention Code — Occupancy Classification: I Florida Fire Prevention Code, 6th Edition (12.2.5.1.2) Assembly Occupancy 3.3.188.2 Assembly use for a Gathering of 50 or more persons for deliberation, entertainment, eating, drinking, amusement, awaiting transportation or similar worship, uses. Egress Requirements Not Sprinklered, no Fire Alarm system Common Path Limit = 20 Ft if more than 50 Persons, 75 Ft if less than 50 Persons Dead -End Limit = 20 Feet. Travel Distance Limit = 200 Feet Min Number of Mean Of Egress: 2 Flame Spread Exits are not protected by a sprinkler system: Class B/II Flame Spread 26-75: 0-450 smoke development. It shall be the responsibility of the General Contractor to submit rating information to thelocal building official if so requested. 12.7.4.1 Fabrics 8c films used for decorative purposes, all draperies and curtains, and similar furnishing shall be in accordance with the provisions of NFPA 10.3.1 Legend Existing 8" CMU Wail to Remain. I Exit/Emergency Light. o �—�► Common Path of Travel. SD Smoke Detector. New Partition Wail. Existing 1 hour FireRated Partition Wall. Note: Additional Exit and Emergency Lights and other life safety components may be required by the field fire Inspector at the time of the fire Final inspection. 35 Ft To Exit Door Egress 36" Swing Doors 34"/0.2 = 170 Ocupants Wm I�ce�p On1� �'o� S}cim�s Y" MIAto41-DAD" Cr 'I e I id i L_.-ARTMENT BLDG. PcR1%'r____ r;fl74ARM FIRE 50PPFii{,13lON___�,_ BAFF: LIFE SAFETY FLOOR PLAN SCALE: 1/4" = 1r-0" MANAGMENT: SHEET TITLE: SHEET No: DESIGN TEAM: ELECTRICAL GENERAL NOTES 1.- OVERALL INSTALLATION: THE INSTALLATION SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC-2014), THE FLORIDA BUILDING CODE (FBC-2017), AND ANY OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES. 2.- COMPLIANCE: WORKMANSHIP, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE EDITION OF THE NEC, NFPA, NEMA, ASTM, OSHA', HRS HEALTH AGENCIES, AND OTHER APPLICABLE NATIONAL, STATE, AND LOCAL CODES AND PERTAINING REGULATIONS ESTABLISHED BY THE RULING AUTHORITY HAVING JURISDICTION. CONTRACTORS SHALL ALSO MEET THE REQUIREMENTS OF OTHER STANDARDS WHERE SUCH REQUIREMENTS ARE MORE STRICT THAN THOSE STANDARDS CITED ABOVE. 3.-MATERIALS: CONTRACTOR SHALL PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE UNDERWRITER'S LABORATORY (UL) LABEL AS APPLICABLE. 4.- PERMITS AND INSURANCE: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEMS AS OUTLINED HEREIN AND SHOWN ON PLANS. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5.- EXISTING CONDITIONS: BEFORE BIDDING, THE CONTRACTOR SHALL VISIT THE JOB SITE AND ASCERTAIN ALL EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITIONS RESULT IN EXTRA MATERIALS OR ANY EXISTING CONDITIONS FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT THE WORK SHALL BE IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETELY WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 6: CUTTING AND PATCHING: MAJOR CUTTING, PATCHING & PAINTING REQUIRED BY THIS CONTRACT WILL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ALL SURFACES SHALL BE RETURNED TO ORIGINAL CONDITIONS AFTER THE INSTALLATION OF THE EQUIPMENT. 7.-THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF THE LOCAL ELECTRIC UTILITY AND THE TELEPHONE COMPANY. 8.-LOAD DATA IS BASED ON INFORMATION PROVIDED TO THE ENGINEER AT THE TIME OF DESIGN. ALL EQUIPMENT AND PANEL SIZES SHALL BE VERIFIED BEFORE ORDERING. 9.-CIRCUITS SHOWN ON PLANS ARE USED TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUIT ROUTING TO SUIT THE JOB CONDITIONS. 10.-FURNISH AND INSTALL ALL FIXTURES AS CALLED FOR ON THE PLANS OR AS SELECTED BY OWNER/ARCHITECT. 11.-ALL CONDUCTORS SHALL BE RUN IN CONDUIT, U.O.N. 12.-INSTALL 3/4" EMPTY CONDUIT TO ALL TELEPHONE, DATA & TV OUTLETS. PROVIDE PULL WIRE. 13.- INTERFERENCE: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES SO THAT INTERFERENCE WITH EXISTING CONDITIONS,. CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL AND STRUCTURAL MEMBERS BE AVOIDED. 14.- PLANS: DRAWINGS ARE BASICALLY DIAGRAMS INTENDED TO DEPICT APPROXIMATELY EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL. PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND DIMENSIONS. 15: ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ACCESIBLE AREAS ONLY AND ABOVE BASE FLOOD ELEVATION. 16: CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATES, IF DIFFERENT FROM THOSE SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 17: ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ALL REQUIRED J-BOXES AND CONDUITS FOR INSTALLATION OF CONTROL WIRING. LOW VOLTAGE CONTROL WIRING AND THEIR TERMINATION IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. 18.-ELECTRICAL METER AND PANEL LOCATIONS SHOWN MAY VARY DEPENDING ON SERVICE ENTRANCE LOCATION. 19: ALL LIGHTING FIXTURES TO BE SELECTED BY THE OWNER/ARCHITECT, U.O.N. AND SHALL BE INSTALLED BY THIS CONTRACTOR. 20.-BALANCE ALL PHASES AT EACH PANEL AND MDP/SERVICE MAINS 21.-CHECK AVAILABLE ELECTRICAL SERVICE CHARACTERISTICS WITH THE LOCAL POWER COMPANY PRIOR TO ORDERING ANY EQUIPMENT. INFORM THE ARCH/ENGINEER IF IT IS DIFFERENT FROM WHAT IS SHOWN ON PLANS. 22.-ELECTRICAL CONTRACTOR SHALL ASSURE THAT ALL FEATURES OF SERVICE COMPLY WITH THE POWER COMPANY'S REQUIREMENTS AND SHALL MAKE ALL NECESSARY ARRANGEMENTS WITH POWER COMPANY FOR SERVICE. ALL EQUIPMENT NOT FURNISHED AND/OR INSTALLED BY THE POWER CO. IS TO BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 23.-U.O.N., COORDINATE REQUIRED A.I.C. RATINGS WITH POWER COMPANY. 24: WHERE MORE THAN ONE DEVICE IS INDICATED AT ANY LOCATION, THESE SHALL BE GANGED UNDER ONE COMMON COVER. 25: QUANTITY AND LOCATION OF ELECTRICAL, TELEPHONE/DATA & TV OUTLETS, LIGHTS AND LIGHT CONTROLS, SHALL BE ADJUSTED TO SUIT THE OWNER'S REQUIREMENTS AS PER OWNER/ARCHITECT INSTRUCTIONS. SAID ARRANGEMENTS SHALL NOT BE IN CONFLICT WITH APPLICABLE CODES. 26: ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS, EXACT LOCATIONS, TYPE AND ARRANGEMENT OF OUTLETS FOR ALL ELECTRICAL FIXTURES, APPLIANCES AND EQUIPMENT, PRIOR TO INSTALLATION. 27: PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL. 28.-CONTRACTOR SHALL FURNISH AS -BUILT DRAWINGS TO THE OWNER UPON COMPLETION OF WORK AND PRIOR TO FINAL PAYMENT. 29: OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET/DAMP LOCATIONS AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER CLASSIFIED AREAS AND SHALL CONFORM TO NEMA STANDARDS. PLASTIC BOXES MAY BE USED WHERE PERMITTED UNDER APPLICABLE CODES AND ORDINANCES. 30.-ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMODATE THE EQUIPMENT SERVED, INCLUDING REJECTION CLIPS AND FUSES, WHEN APPLICABLE. SWITCHES SHALL BE HP RATED, QUICK -MAKE, QUICK -BREAK, IN NEMA 1 ENCLOSURES FOR INDOOR AND NEMA 3R FOR OUTDOOR. ELECTRICAL LEGEND (USE THOSE THAT APPLY) & 20A, 120V SINGLE RECEPTACLE. 20 A., 120., V., DUPLEX RECEPTACLE,GROUNDING TYPE, U.O.N. MOUNTED 18"A.F.F. OR AS DIRECTED BY ARCHITECT. 20A, 120V GFI DUPLEX RECEPTACLE. 20A, QDUPLEX RECEPTACLE @ 18" AFF, U.O.N. ®FLOOR MOUNTED 20A,QDUPLEX RECEPTACLE ®20A, 120V CEILING MOUNTED RECEPTACLE. 208V SPECIAL PURPOSE RECEPTACLE. IVSI� LIGHTING SWITCH @ 48" AFF. 63 3-WAY LIGHTING SWITCH @ 48" AFF. 3 IG SWITCH WITH OCCUPANCY SENSOR. [C PUSH BUTTON. E:� SAFETY DISCONNECT SWITCH. SIM] ELECTRIC PANEL. GD CEILING AND WALL JUNCTION BOX. M EXHAUST FAN. [1]V TV OUTLET PHONE DATA OUTLET (AS PER OWNER REQUEST). 2'x 4' FLUORESCENT FIXTURE. ®2'x 4' FLUORESCENT FIXTURE LAY -IN EMERGENCY. 8"x 4' FLUORESCENT FIXTURE. RECESSED MOUNTED FIXTURE. WALL /PEDESTAL MOUNTED LIGHT. 7Q WALL PACK LIGHT. EMERGENCY LIGHT W/BATTERY BACK UP AND CONNECTED AHEAD OF ANY SWITCH. EXIT LIGHT W/BATTERY BACK UP AND ® CONNECTED AHEAD OF ANY SWITCH. (SHALL NO EXCEED 5 WATT PER SIDE c = ABOVE THE COUNTER. WP = WEATHER PROOF. VP = VAPOR PROOF. NOTE: ALL ELECTRICAL,TELEPHON/DATA AND TV OUTLETS TO BE INSTALLED AT 18" A.F.F., UNLESS OTHERWISE NOTED & COORDINATE WITH FURNITURE. COORDINATE EXACT LOCATION, COLORS AND STYLE WITH OWNER/ARCH. R#2 #2 R#1 #1 NM ® WPLL A-2,4,6 A-7 WPLL A-1,3,7 A-7 r ELECTRICAL ROOF PLAN ELECTRICAL FLOOR PLAN (POWER) YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 OF QC Pr1 L. S*O*.- s PE 7542?, j L YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS • a a _ _ • e e • , • e e Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE Al ev 5/27/2019 ev 6/18/2019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: Bar Counter Top Details. Travel Distance From Bar Bar Opening Detail SHEET No: ELECTRICAL FLOOR PLAN (POWER) ELL DESIGN TEAM: ELECTRICAL GENERAL NOTES 1: OVERALL INSTALLATION: THE INSTALLATION SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC-2014), THE FLORIDA BUILDING CODE (FBC-2017), AND ANY OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES. 2: COMPLIANCE: WORKMANSHIP, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE EDITION OF THE NEC, NFPA, NEMA, ASTM, OSHA, HRS HEALTH AGENCIES, AND OTHER APPLICABLE NATIONAL, STATE, AND LOCAL CODES AND PERTAINING REGULATIONS ESTABLISHED BY THE RULING AUTHORITY HAVING JURISDICTION, CONTRACTORS SHALL ALSO MEET THE REQUIREMENTS OF OTHER STANDARDS WHERE SUCH REQUIREMENTS ARE MORE STRICT THAN THOSE STANDARDS CITED ABOVE. 3.-MATERIALS: CONTRACTOR SHALL PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE UNDERWRITER'S LABORATORY (UL) LABEL AS APPLICABLE. 4.- PERMITS AND INSURANCE: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEMS AS OUTLINED HEREIN AND SHOWN ON PLANS. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5: EXISTING CONDITIONS: BEFORE BIDDING, THE CONTRACTOR SHALL VISIT THE JOB SITE AND ASCERTAIN ALL EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITIONS RESULT IN EXTRA MATERIALS OR ANY EXISTING CONDITIONS FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT THE WORK SHALL BE IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETELY WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 6: CUTTING AND PATCHING: MAJOR CUTTING, PATCHING & PAINTING REQUIRED BY THIS CONTRACT WILL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ALL SURFACES SHALL BE RETURNED TO ORIGINAL CONDITIONS AFTER THE INSTALLATION OF THE EQUIPMENT. T-THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF THE LOCAL ELECTRIC UTILITY AND THE TELEPHONE COMPANY. 8: LOAD DATA IS BASED ON INFORMATION PROVIDED TO THE ENGINEER AT THE TIME OF DESIGN. ALL EQUIPMENTAND PANEL SIZES SHALL BE VERIFIED BEFORE ORDERING. 9: CIRCUITS SHOWN ON PLANS ARE USED TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUIT ROUTING TO SUIT THE JOB CONDITIONS. 10.-FURNISH AND INSTALL ALL FIXTURES AS CALLED FOR ON THE PLANS OR AS SELECTED BY OWNER/ARCHITECT. 11.-ALL CONDUCTORS SHALL BE RUN IN CONDUIT, U.O.N. 12. INSTALL 3/4" EMPTY CONDUIT TO ALL TELEPHONE, DATA & TV OUTLETS. PROVIDE PULL WIRE. 13.- INTERFERENCE: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES SO THAT INTERFERENCE WITH EXISTING CONDITIONS, CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL AND STRUCTURAL MEMBERS BE AVOIDED. 14: PLANS: DRAWINGS ARE BASICALLY DIAGRAMS INTENDED TO DEPICT APPROXIMATELY EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL. PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND DIMENSIONS. 15: ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ACCESIBLE AREAS ONLY AND ABOVE BASE FLOOD ELEVATION. 16: CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATES, IF DIFFERENT FROM THOSE SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 17.-ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ALL REQUIRED J-BOXES AND CONDUITS FOR INSTALLATION OF CONTROL WIRING. LOW VOLTAGE CONTROL WIRING AND THEIR TERMINATION IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. 18.-ELECTRICAL METER AND PANEL LOCATIONS SHOWN MAY VARY DEPENDING ON SERVICE ENTRANCE LOCATION. 19.-ALL LIGHTING FIXTURES TO BE SELECTED BY THE OWNER/ARCHITECT, U.O.N. AND SHALL BE INSTALLED BY THIS CONTRACTOR. 20 :BALANCE ALL PHASES AT EACH PANEL AND MDP/SERVICE MAINS. 21.-CHECK AVAILABLE ELECTRICAL SERVICE CHARACTERISTICS WITH THE LOCAL POWER COMPANY PRIOR TO ORDERING ANY EQUIPMENT. INFORM THE ARCH/ENGINEER IF IT IS DIFFERENT FROM WHAT IS SHOWN ON PLANS. 22: ELECTRICAL CONTRACTOR SHALL ASSURE THAT ALL FEATURES OF SERVICE COMPLY WITH THE POWER COMPANY'S REQUIREMENTS AND SHALL MAKE ALL NECESSARY ARRANGEMENTS WITH POWER COMPANY FOR SERVICE. ALL EQUIPMENT NOT FURNISHED AND/OR INSTALLED BY THE POWER CO. IS TO BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 23.-U.O.N., COORDINATE REQUIRED A.I.C. RATINGS WITH POWER COMPANY. 24: WHERE MORE THAN ONE DEVICE IS INDICATED AT ANY LOCATION, THESE SHALL BE GANGED UNDER ONE COMMON COVER. 25.-QUANTITY AND LOCATION OF ELECTRICAL, TELEPHONE/DATA & TV OUTLETS, LIGHTS AND LIGHT CONTROLS, SHALL BE ADJUSTED TO SUIT THE OWNER'S REQUIREMENTS AS PER OWNER/ARCHITECT INSTRUCTIONS. SAID ARRANGEMENTS SHALL NOT BE IN CONFLICT WITH APPLICABLE CODES, 26: ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS, EXACT LOCATIONS, TYPE AND ARRANGEMENT OF OUTLETS FOR ALL ELECTRICAL FIXTURES, APPLIANCES AND EQUIPMENT, PRIOR TO INSTALLATION. 27: PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL. 28:CONTRACTOR SHALL FURNISH AS -BUILT DRAWINGS TO THE OWNER UPON COMPLETION OF WORK AND PRIOR TO FINAL PAYMENT, 29: OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET/DAMP LOCATIONS AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER CLASSIFIED AREAS AND SHALL CONFORM TO NEMA STANDARDS. PLASTIC BOXES MAY BE USED WHERE PERMITTED UNDER APPLICABLE CODES AND ORDINANCES. 30:ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMODATE THE EQUIPMENT SERVED, INCLUDING REJECTION CLIPS AND FUSES, WHEN APPLICABLE. SWITCHES SHALL BE HP RATED, QUICK -MAKE, QUICK -BREAK, IN NEMA 1 ENCLOSURES FOR INDOOR AND NEMA 3R FOR OUTDOOR. ELECTRICAL LEGEND (USE THOSE THAT APPLY) e- 20A, 120V SINGLE RECEPTACLE. 20A., 120., V., DUPLEX RECEPTACLE,GROUNDING TYPE, U.O.N. MOUNTED 18" A.F.F. OR AS DIRECTED BY ARCHITECT. �i 20A, 120V GFI DUPLEX RECEPTACLE. 20A, QDUPLEX RECEPTACLE @ 18" AFF, U.O.N. ® FLOOR MOUNTED 20A, QDUPLEX RECEPTACLE ®20A, 120V CEILING MOUNTED RECEPTACLE. ® 208V SPECIAL PURPOSE RECEPTACLE. 40 LIGHTING SWITCH @ 48" AFF. EA 3-WAY LIGHTING SWITCH @ 48" AFF. 3 oSWITCH WITH OCCUPANCY SENSOR. 0 PUSH BUTTON. pl SAFETY DISCONNECT SWITCH. !J ELECTRIC PANEL. m CEILING AND WALL JUNCTION BOX, 10 EXHAUST FAN. 4 TV OUTLET. PHONE DATA OUTLET (AS PER OWNER REQUEST). ® 2'x 4' FLUORESCENT FIXTURE. LA2'x 4' FLUORESCENT FIXTURE LAY -IN EMERGENCY. ® 8"x 4' FLUORESCENT FIXTURE. O RECESSED MOUNTED FIXTURE. �-¢ WALL /PEDESTAL MOUNTED LIGHT. WALL PACK LIGHT. EMERGENCY LIGHT W/BATTERY BACK UP AND CONNECTED AHEAD OF ANY SWITCH. EXIT LIGHT W/BATTERY BACK UP AND ® CONNECTED AHEAD OF ANY SWITCH. (SHALL NO EXCEED 5 WATT PER SIDE; c = ABOVE THE COUNTER. WP = WEATHERPROOF. VP = VAPOR PROOF. NOTE: ALL ELECTRICAL,TELEPHOWDATA AND TV OUTLETS TO BE INSTALLED AT 18" A.F.F., UNLESS OTHERWISE NOTED & COORDINA7, WITH FURNITURE. COORDINATE EXACT LOCATION, COLORS AND STYLE WITH OWNER/ARCH. R#2 �CLY #2 R.T.0 #1 NZ ® L= WPj A-2,4,6 A-7 wP A-1,3L/ A-7 [EI Al ATG ®A-11 ®A-11 SIGN @A-9 ®A-11 r ELECTRICAL ROOF PLAN SCALE: 1/4" = 1'-0" •*• I A-44 ec 46 — — U'4 A-130,32 IIXII A-18,20 W Q ESPRESSO I IKITCHEN HOOD nl LL 1 MACHINE I 1 23 SYSTEM CONTROL PANEL w (SEE HOOD SYSTEM W NV A-11 SHOP DRAWINGS) QJ -1 38 -125 I REF. GAS A $ RANGE -1 25 PREP. AREA 48 ¢ u A-1�2� KITCHEN < i 1 25 m b A-1 24 GAS -140 FRYER A-13 -125 SK I REF. c S FS SEATING AREA A 1 OVEN 1 25 fable ,e' a m• a I A-1 14,1 a A- 1 c D/W KER i A-1 22,24 . Ll 26,28 0 0 0 0 fA-330 a a Lc� @72"A. F.F. OFA-33MENSA-37�MENS SEATINGAREA SEATING AREA A-31 RLOCKEDH R.T.U. 1A � A-3*3 A- 5 A-17 A-29 --------- I I I 1 I I I I STORAGE AREA I I I I DRY I STORAGE NFRA HALLWAY n rnnli ; S„_ cL �„ APTMENr ' _29 IPA-29 n FIRE ELECTRICAL FLOOR PLAN (POWER) \fOi"D M SCALE: 1/4" = 1'-0" YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 .Fzc NL.so.'• <is •p PE 75423 YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS • • s PROJECT: Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE A\ ev 5/27/2019 DATE: 5/1312019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: New Bar area layout New Electrical Panels MR492M ELECTRICAL ..•FLOOR PLAN (POWER) E1.0 ELECTRICAL GENERAL NOTES 1.- OVERALL INSTALLATION: THE INSTALLATION SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC-2014), THE FLORIDA BUILDING CODE (FBC-2017), AND ANY OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES. 2 - COMPLIANCE: WORKMANSHIP, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE EDITION OF THE NEC, NFPA, NEMA, ASTM, OSHA, HRS HEALTH AGENCIES, AND OTHER APPLICABLE NATIONAL, STATE, AND LOCAL CODES AND PERTAINING REGULATIONS ESTABLISHED BY THE RULING AUTHORITY HAVING JURISDICTION. CONTRACTORS SHALL ALSO MEET THE REQUIREMENTS OF OTHER STANDARDS WHERE SUCH REQUIREMENTS ARE MORE STRICT THAN THOSE STANDARDS CITED ABOVE. 3.-MATERIALS: CONTRACTOR SHALL PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE UNDERWRITER'S LABORATORY (UL) LABEL AS APPLICABLE. 4: PERMITS AND INSURANCE: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEMS AS OUTLINED HEREIN AND SHOWN ON PLANS. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5.- EXISTING CONDITIONS: BEFORE BIDDING, THE CONTRACTOR SHALL VISIT THE JOB SITE AND ASCERTAIN ALL EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITIONS RESULT IN EXTRA MATERIALS OR ANY EXISTING CONDITIONS FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT THE WORK SHALL BE IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETELY WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 6: CUTTING AND PATCHING: MAJOR CUTTING, PATCHING & PAINTING REQUIRED BY THIS CONTRACT WILL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ALL SURFACES SHALL BE RETURNED TO ORIGINAL CONDITIONS AFTER THE INSTALLATION OF THE EQUIPMENT. 7: THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF THE LOCAL ELECTRIC UTILITY AND THE TELEPHONE COMPANY. 8.-LOAD DATA IS BASED ON INFORMATION PROVIDED TO THE ENGINEER AT THE TIME OF DESIGN. ALL EQUIPMENT AND PANEL SIZES SHALL BE VERIFIED BEFORE ORDERING. 9.-CIRCUITS SHOWN ON PLANS ARE USED TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUIT ROUTING TO SUIT THE JOB CONDITIONS. 10 -FURNISH AND INSTALL ALL FIXTURES AS CALLED FOR ON THE PLANS OR AS SELECTED BY OWNER/ARCHITECT, 11.-ALL CONDUCTORS SHALL BE RUN IN CONDUIT, U.O.N. 12.-INSTALL 3/4" EMPTY CONDUIT TO ALL TELEPHONE, DATA & TV OUTLETS. PROVIDE PULL WIRE. 13: INTERFERENCE: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES SO THAT INTERFERENCE WITH EXISTING CONDITIONS, CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL AND STRUCTURAL MEMBERS BE AVOIDED. 14.- PLANS: DRAWINGS ARE BASICALLY DIAGRAMS INTENDED TO DEPICT APPROXIMATELY EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL. PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND DIMENSIONS, 15.-ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ACCESIBLE AREAS ONLY AND ABOVE BASE FLOOD ELEVATION. 16.-CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATES, IF DIFFERENT FROM THOSE SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER. CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 17.-ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ALL REQUIRED J-BOXES AND CONDUITS FOR INSTALLATION OF CONTROL WIRING. LOW VOLTAGE CONTROL WIRING AND THEIR TERMINATION IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. 18.-ELECTRICAL METER AND PANEL LOCATIONS SHOWN MAY VARY DEPENDING ON SERVICE ENTRANCE LOCATION. 19: ALL LIGHTING FIXTURES TO BE SELECTED BY THE OWNER/ARCHITECT, U.O.N. AND SHALL BE INSTALLED BY THIS CONTRACTOR. 20.-BALANCE ALL PHASES AT EACH PANEL AND MDP/SERVICE MAINS 21.-CHECK AVAILABLE ELECTRICAL SERVICE CHARACTERISTICS WITH THE LOCAL POWER COMPANY PRIOR TO ORDERING ANY EQUIPMENT. INFORM THE ARCH/ENGINEER IF IT IS DIFFERENT FROM WHAT IS SHOWN ON PLANS. 22.-ELECTRICAL CONTRACTOR SHALL ASSURE THAT ALL FEATURES OF SERVICE COMPLY WITH THE POWER COMPANY'S REQUIREMENTS AND SHALL MAKE ALL NECESSARY ARRANGEMENTS WITH POWER COMPANY FOR SERVICE. ALL EQUIPMENT NOT FURNISHED AND/OR INSTALLED BY THE POWER CO. IS TO BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 23.-U.O.N., COORDINATE REQUIRED A.I.C. RATINGS WITH POWER COMPANY. 24.-WHERE MORE THAN ONE DEVICE IS INDICATED AT ANY LOCATION, THESE SHALL BE GANGED UNDER ONE COMMON COVER. 25: QUANTITY AND LOCATION OF ELECTRICAL, TELEPHONE/DATA & TV OUTLETS, LIGHTS AND LIGHT CONTROLS, SHALL BE ADJUSTED TO SUIT THE OWNER'S REQUIREMENTS AS PER OWNER/ARCHITECT INSTRUCTIONS. SAID ARRANGEMENTS SHALL NOT BE IN CONFLICT WITH APPLICABLE CODES. 26.-ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS, EXACT LOCATIONS, TYPE AND ARRANGEMENT OF OUTLETS FOR ALL ELECTRICAL FIXTURES, APPLIANCES AND EQUIPMENT, PRIOR TO INSTALLATION. 27.-PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL. 28 -CONTRACTOR SHALL FURNISH AS -BUILT DRAWINGS TO THE OWNER UPON COMPLETION OF WORK AND PRIOR TO FINAL PAYMENT. 29.- OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET/DAMP LOCATIONS AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER CLASSIFIED AREAS AND SHALL CONFORM TO NEMA STANDARDS. PLASTIC BOXES MAY BE USED WHERE PERMITTED UNDER APPLICABLE CODES AND ORDINANCES. 30.-ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMODATE THE EQUIPMENT SERVED, INCLUDING REJECTION CLIPS AND FUSES, WHEN APPLICABLE. SWITCHES SHALL BE HP RATED, QUICK -MAKE, QUICK -BREAK, IN NEMA 1. ENCLOSURES FOR INDOOR AND NEMA 3R FOR OUTDOOR. ELECTRICAL LEGEND (USE THOSE THAT APPLY) ¢} 20A, 120V SINGLE RECEPTACLE. 20 A., 120., V., DUPLEX RECE PTACLE,GROUN DING TYPE, U.O.N. MOUNTED 18" A.F.F. OR AS DIRECTED BY ARCHITECT. 20A, 120V GFI DUPLEX RECEPTACLE. 20A, QDUPLEX RECEPTACLE @ 18" AFF, U.O.N. ®FLOOR MOUNTED 20A, QDUPLEX RECEPTACLE ®20A, 120V CEILING MOUNTED RECEPTACLE. e 208V SPECIAL PURPOSE RECEPTACLE. ,64 LIGHTING SWITCH @ 48" AFF. � 3-WAY LIGHTING SWITCH @ 48" AFF. SWITCH WITH OCCUPANCY SENSOR. DI [I] PUSH BUTTON. [:]1 SAFETY DISCONNECT SWITCH. OEM ELECTRIC PANEL. ® CEILING AND WALL JUNCTION BOX. 10 EXHAUST FAN. QV TV OUTLET. PHONE DATA OUTLET (AS PER OWNER REQUEST). 2'x 4' FLUORESCENT FIXTURE. LA2'x 4' FLUORESCENT FIXTURE LAY -IN EMERGENCY. ® 8"x 4' FLUORESCENT FIXTURE, 0 RECESSED MOUNTED FIXTURE. ' Y WALL /PEDESTAL MOUNTED LIGHT. 9D WALL PACK LIGHT. EMERGENCY LIGHT W/BATTERY BACKUP AND CONNECTED AHEAD OF ANY SWITCH. EXIT LIGHT W/BATTERY BACK UP AND ® CONNECTED AHEAD OF ANY SWITCH. (SHALL NO EXCEED 5 WATT PER SIDE c = ABOVE THE COUNTER. WP= WEATHERPROOF. VP = VAPOR PROOF. NOTE: ALL ELECTRICAL;TELEPHON/DATA AND TV OUTLETS TO BE INSTALLED AT 18" A.F.F., UNLESS OTHERWISE NOTED & COORDINATE WITH FURNITURE. COORDINATE EXACT LOCATION, COLORS AND STYLE WITH OWNER/AR;;)H. i R.T.0 #2 ® R #2 #1 VN ® / I WP I� WPJJ A-2,4,6 lb A-1,3,7 A-7 ELECTRICAL ROOF PLAN 1/4" = 1' ELECTRICAL FLOOR PLAN (POWER) SCALE: 1/4" = 1'-0" voib pep Xo r DESIGN TEAM: YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21 ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE:75423 OF FCC PNL so I/ of/, J` PE 754U f � �ONA1- YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS PROJECT: Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE <Y N� �Rev xh' 1/17/2019 L 'Y? �Rev 4 2/13/2019 /5 a-1 ev 5C 3/18/2019 6�2ev6 �1 8 4/8/2019 �( Rev 7� 5/12/2019 DATE: 11/10/2018 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: New Ear areo layout New Electrical Panels LLECTRICAL FLOOR PLAN (POWER) SHEET No: E1.0 DESIGN TEAM: 1 m .i PANEL PANEL PANEL "A2" "A" "Al" 120/208V 120/208V 120/208V 150A, 30 250A, 30 150A, 10 10 KAIC 10 KAIC 10 KAIC 40 POS. 30 POS. 42 POS. MCB 225A G.., 1re.aa,x,Eaa H�t Main 1 Of 1 Exouse1000 Am s House PPanel 100KAC H" 225 Amps Yam.q d.s a.%Avwcosres _.m q.M""YN"H��,,T" PissQH. . 1wAw`..pe."a8: 1# 3/0 Cu (GND) IN 3/4" C.— TWO 5/8" X 10' GALV. GND. RODS 6'-0". APART MIN. ,SG �a L-V 4"x8" COPPER GROUND BUS BAR BY STORM COOPER OR APPROVED EQUAL 3/�4" C.W. METAL PIPE - 1# 3/0 CU GND IN 1/2" C. TO CONCRETE ENCASED STEEL REBAR AT NEW STRUCTURE. 1 #6 CU (GND) IN 1/ PHONE & CABLE/TV C NOTE: A DISCONNECTING MEANS SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION FOR SERVICING THE BALLAST OF ALL FLUORESCENT FIXTURES THAT UTILIZE DOUBLE -ENDED LAMPS. THESE DISCONNECTS SHALL DISCONNECT SIMULTANEOUSLY ALL CONDUCTORS, INCLUDING THE GROUND CONDUCTOR AS PER NEC. 410.73 (G). NOTE: EGRESS ILLUMINATION SHALL COMPLY WITH FBC-1008 (MINIMUM 1 FOOT CANDLE LIGHTING DESIGN COMPLIES WITH FBC, CE-405.1 ELECTRICAL EQUIPMENT, LUMINARIES, CONTACTORS, ASSEMBLIES & DEVICES SHALL BE LISTED BY A NRTL AND SUITABLE FOR THE APPLICATION. MAIN #1 OF LOAD ANALYSIS BASED ON 120/24OV, 30, 4W (OPEN DELTA) TENANT #1: (RESTAURANT) (Estimated Load) 10 LOADS: 2,410 SF is 15VA/SF= 36,150 VA 30 LOADS: 2,410 SF x 8VA/SF= 19,280 VA 10 KITCHEN LOADS: 6000 VA TENANT #2: (EXISTING U.S. POST OFFICE) 10 LOADS: 38,400 VA TENANT #3: (RESTAURANT) (Estimated Load) 10 LOADS: 2,520 SF x 15VA/SF= 37,800 VA 30 LOADS: Z520 SF x 8VA/SF= 20,160 VA 10 KITCHEN LOADS: 4000 VA TENANT #4: (RETAIL) 10 LOADS: 1,011 SF x 20VA/SF= 20,220 VA TENANT #5:. (RETAIL) 10 LOADS: 494 SF x 201 9,880 VA TENANT #6: (RETAIL) 10 LOADS: 493 SF x 20VA/SF= 9,860 VA OA 081 0C 1ON TENANT #1: (RESTAURANT) 10 LOADS: 175 A -0- A 175 A 175 A 30 LOADS: 47A 47A 47A -0- SUB-TOTAL 222 A 47 A 222 A 222 A TENANT #2: (EXSTING U.S. POST OFFICE) 10 LOADS: 160A -0- 160A 160A TENANT #3: (RESTAURANT) 10 LOADS: 174 A -0- A 174 A 174 A 30 LOADS: 48A 48A 48A -0- SUB-TOTAL 222 A 48 A 222 A 222 A TENANT #4: (RETAIL) 10 LOADS: 84A -0- 84A 84A TENANT #5: (RETAIL) 10 LOADS: 41A -0- 41A 41A TENANT #6: (RETAIL) 10 LOADS: 41A -0- 41A 41A HOUSE: (PANEL-H) 10 LOADS: 50.7 A -0- 50.7 A 50.7 A 30 LOADS: 9 A 9 A 9 A O A SUB -TOTAL 59.7 A 9 A 59.7 A 59.7 A TOTAL 670 A 104 A 670 A 670 A I YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21 ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 NOF Ft' C � L. S 07/P PE 7542: A,70NA1�r YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS EXISTING ELECTRICAL RISER DIAGRAM Q awu•• uee PHASE 30 q PANEL "A-G" 30 PHASEVOLTAGE PANEL "A" 61EMEN6 30 "A-P.1 ENS VOLTAGE IES CRECMAKEUSIEMENS aREOUIBALENT ORKE VOLTHASEAGE: PANEL OMAKER EQUII A OR EOUIBgLENT • .94. 125A PANEL AMPS'. 125 AMPS (BRANCH BREAKERS TYPE OP. 10 KAIC) PANEL AMPS 250A PANELAMPS:260 AMPS (BRANCH BREAKERS TYPE OP, ISSAS) MAIN MAIN BREAKER: Z15.4 PANEL 125A pgNELgMPS: 125 AMPS (BRANCH BREAKERS TYPE OP, IO KAICj • •Is Y 0 HACR= BREAKER SURABLE FOR THE PROTECTION OF HEATNG,NO AND LV-MALOWVOLTAGETRAN.SFORMER. SWD= ONOFF SMTCHING DUN. HACK= BREAKER SUITABLE FOR THE PROTECTION OF HEATNSONS AND TV = NA LOW VOLTAGE TRANSFORMER. SµAD BROKE SWITCHING WN. BACK BREAKER SUITABLE FOR THE PROTECTOR OF HEOTNG,NC AND LV=V]4 LOWVOLTAGETRNISFORMER. SWB=011DFF6WITCHMGWIY •• • • •• REFRIGERATOR EQUIPMENT. C=VM CONTACTOR,NCL=NQNGONCURRENTLOAO. REFRIGERATION EQUIPMENT C=VIA CONTACTOR NCL= WOECONCURRENT LOAD. REFRIGERATION BODEMENT, C=VIA COMPACTOq. NHLIXIGIRREMLOAO. CL=NO ABC I= BREAKER SUITABLE FOR ARCFAULT CRT. PROTECTION INTERRUPTER BREAKER. T=VIAnMER. 13= ISOLATED GROUND CRT. AEG= BREANFR SUITABLE FOR ARCFAULT W. PROTECTION INTERRUPTER BREWER, T=VIATMER IS-GOIAGGETROUNOCKT ANSI=BREAKER SUITABLE FOR MCFAULL ORT PROTECTION INTERRUPTER BREAKER. T=VVTIXER. 1C_=NOAlEDGRWNOCM •e•• GFI=GROUND FAULT INIFAfNPTER &tEMFR. HID = RATED SREAKERp6PER NEC 210830j. SL=BRFARFA INTTN SHUNi1RIP GFl=GROUND FAULT IMERRUPIp2BREAKER. HID =MIFOBREpS 4Ge3pl). AI(ERPER ST=BREMERIMPHSHUNTTRIP. GFI= GROUND FAULT INTERRUPTER BREAKER. HID= RATED SNEAKER AS PER NEC ZuHN0). Si= BREAKER WITH SHUNT TRIP. C USE PE OL WE WIRE ON PHASE WIRE BNR OL USE CM C USE PEC OL BNR WIRE ON PHASE N WIRE BKR OL CFt C BNR WIRE ON PHABE ON WIRE BKR C No AMP AVID SIZE SIN VA , 612E AWG MP PEC No No AM AWG SIZE VA Vq 612E AWG AMP PEC USE No. No. UBE SPE VOLT AWG SIZE VA VA` SIZE AWG AMP OLT PE USE No: 1 R.T.U.#1" 208 t00 3 1-1/4 6CO3 11000 3,0. 1 6 fire EGA R.TU. M^ 2 1 SHUN TRIP 100 A PANEL "At" 240 t25 2 1-1/4 P025 25V0 "'-- -. 49W 2 iN 100 2q0 PANEL"q-t" 2 t HEAT LAMP 208 20 12 12 iW0 125 2 3 8,0AD 11000 30W 4 3 17025 25130 -- 129W q 3 1000 125 4 5 BOW _ 1101, 3000 8 5_113 17WS _.----1]025 6 5 HEATLAMP 208 20 12 t2 1000 125 fi ] ROOF RECEPTACLES OF 120 A 12 12 W0 500 - 8 7 ROOFRECEPTACLES OFF 120 20 12 12 5W 500 -'_ e ] t000 9 SIGN 120 20 12 12 WO - 10 9 SIGN 120 20 12 12 t200 t2W -: - 10 9 HEAT LMAP 208 20 12 1R 1000 _ t25 10 11 WINDOW OUTLEF6 120 211 12 12 600 12 it WINDOW OUTLETS 120 20 t 12 1200 .. _ -_ 1200 i2 t1 f000 t25 12 13 BATHROOM RECEPTACLES GFI 120 20 12 t2 30W I 314 8 4C 2W OVER •' IS 13 BATHROOM RECEPTACLES GFI 120 20 12 12 500 00 ___ _ 14 13 HEAT LAMP 2W PIT 12 12 1000 125 3W0 E4 8 40 206 OVER 14 15 BATHROOM HAND DRYER GFI 120 20 12 12 3,800 300 i6 15 BATHROOM HAND DRYER GFI 120 20 12 t2 1000 t000 -__ t6 15 ID00 - _. 3625 3,500 3500 16 1] BATHROOM HAND DRYER GET 120 ID 12 12 -- 2300 15M 12 12 20 2. FREEZER" 18 1] BATHROOM HAND DRYEH OR 1. 20 12 12 1,00 .__ _ 1000 18 17 2500 3,500 2500 V2 12 20 208 FREEZER19 BqRRECEPTACLES GFI 120 20 12 12 ;'=_._ __-_-, 1500 20 i9 BAR RECEPTACLES GFI 120 ID R t2 1500 1500 '_=:""- 20 19 -'---- 2500 2500 20 21 BAR RECEPTACLES GFI 120 20 12 12 -- 2225-=- 1225 1p t2 20 208 ICE MACHINE" 22 21 BAR RECEPTACLES GFI 120 20 12 12 1,500 -'�.- 1500 _:_ 22 21 -""'""' ..-_.. _._ 2,225 12 t2 20 NB ICE MACHINE^ 22 23 KITCHEN RECEPTACLES GFI 120 2] 12 12 — - 2225 1225 24 23 KITCHEN RECEPTACLES GFI 120 20 12 12 150 "-- 1500 24 23 KITCHEN RECEPTACLES GFI 120 20 12 12 1,500 ""'3]25 2225 24PREPgRATIONAREA RECEPTACLES GFI 121 20 12 12 I 2250-- - 1,2W t2 12 20 2W OISHWgBHER 26 25 PREPARATION AREARECEPTACLEBGFI 120 20 12 1/2 1500 t0O -'-'-;-'- 26 25 PREPARATION AREA RECEPTACLES GFI 120 2O 12 12 IE 2,]50 '-- 1250 12 12 20 2Ja DISHWASHER26 POINTOF SAL£GFI 120 20 4 12 _ _. 2,050--'"-" 125028 27 POINT OF 6AlE GFI ikl 20 t2 12 800 80 28 Zl pREPPRATION PRFA RECEPTACLESGFI RO 2O 12 t2 1500 _-- 2,050 125020 29 GENERALRECEPT... 121 ID 12 12 --- ?OW 100 i2 20g ESPRESSO MACHINE 30 29 GENERAL RECEPTACLES 120 20 12 12 t00 - __ __ ID00 30 29 GENERPL RECEPTACLEB 120 20 12 12 1000 '-- -- 25W 1$0 12 12 ID 200 ESPRESSO MACHINE 3031GENERALRECEPIiYF ES 12U20 12 12 200 31 GENERAL RECEPTACLES 1A 20 12 1Q 1000 1000 --'---' -'---- 32 31 GENERPL RECEPTACLES 120 30 12 12 1000 2500 -' - 150 32 33 OFFICE RECEPTACLEB 120 20 t2 12 1300--'-'-- 300 Sao 12 j1220 20 120 GqS FRYER 34 33 OFFICE RECEPTACLES 120 20 t2 iR 1,OW tOW 3q 33 OFFICE RECEPTACLES 120 20 12 t2 1,000 131I0 3U0 12 12 N 120 __ 1300CUT 12 2ll 120 GA6 RANGE 3S 35 OFFICE RECEPTACLES tED 20 12 12 1,p0 1,00 36 35 OFFICE RECEPTACLES 120 20 12 iQ t000 1,300 300 t2 t2 20 12O GA6 RANGE3] BATHROOMS IXHAUST FANB 120 20 12 12 203 - 100 12 20 iN REFRIGERATOR 38 37 BATHROOMS E%HAUST FANB t20 2O 12 12 tOW 100 - 38 3] BATHROOMS E%HAUST FPN6 t20 20 12 12 t000 200 '---'--- = 100 t2 12 20 120 REFRIGERATOR39 MOP RINK E%HAU6T FAN 120 20 12 12 iS00 '- 1,OW 12 211 I REFRIGERATOR 40 M MOP SINK E%HAUST FAN 1N 20 12 12 503 SW 4p 39 NITCXEN LIGHTS t20 20 12 1Q 500 - t$00 1,00 12 12 20 120 REFRIGERATOR 40 41 LIGHTING CONTACTOR 120 20 t2 12 5W 500 42 41 1,00 tl2 12 2l1 120 WINE 000LER 42 'SEELOADCALCVUTION LOgO PER PNABE 22]50214]S 1B425 —I 43 LIGHTINGTIMER 120 20 12 IQ 50 WO 40 ^VERIFY NAME PLATE SU&TOTAL LOAD 45 LIGHTS 1N 20 12 12 12W '-'--'- 1200 '"" •SEE LOADCALCULATION LOAD PER PHASE t0125 tt225 11050 LoaUCalcol.r., Laos lrsaos 1 "VERIFY NAME PATE SUB -TOTAL LOAD 0 Eq"ignert oad=32400va Ecu.sp EquipneM Loco=62fi50 va 4] SEATINKITCHENBRATHROOM 6EliING AREA LIGHTS 120 20 12 1,2W t200 as 49 21 COMinuos Lgek=Ova 25%CQGrppA1E Ms=Ova 9 49 SEATING ARE q LIGHtS In 20 12 12 1,2W 1200 W L MWM= Ova 1,200 va TPg St SEATING gREA LIGNT3 120 20 12 12 12W 20W ._ 800 12 12 20 120 GAB WATER HEATER n Comesesset Tdal Connede!VA=32400va Fee VA 6GWVa TOWI VA=83BSOva 'BEELORD LOAD PER PHASE 32 07 3q,33 24425 S =n QNec%as FeTNEOTade 2200=25820 va Pare%asper TeMe va AMECALCULATION ^VERIFY NAME PLATE BUB-TOTAL LOAD 16 Parel Lead ,NEC1240 V = t 51060 732=13 Area Panel Laos =51080.R4N1 ]32=t23 Pmry Load Calcolatbn Egmgnmes.=9162900 25'La"'Nses-1, 9W va 25%Wr9esl ,200 va V FEE- ra p=93]25 80%as Va+NEC.Tade C o 732-IN 5 Was Panel Lgaa=]49e6rz4a•T732=1eDs aaFa P I I I 2 BAR I I I I I I I I I / 1 I A-49 — \ / TO CONTACTOR 51 IN SUPPLY ROOM TO CONTACTOR T IN SUPPLY ROOM A-47- TO CONTACTOR �. IN SUPPLY ROOM (1 1 SEATING AREA 53 II ------------ II I I II I I I I I I I I I -Storage Area 5,7 KITCHEN i PREP. AREA 1 I I 3 .° I I ( 1 \ j 11 A-45\ LIGHTING CONTACTOR / 1 TO CONTACTOR &ASTRONOMIC TIMER LOCATION (PROVIDE 2 HOUR MANUAL I T IN SUPPLY ROOM OVERRIDE SWITCH FOR TIMER) PANEL A. 410 PANEL Women / PANE` A-V r Mens I / i I I I I I I i i I PROJECT: Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE ev 5/27/2019 ev 611812019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: Bar Counter Top Details. Travel Distance From Bar Bar Opening Detail ELECTRICAL FLOOR PLAN (LIGHTING) SHEET No: ELECTRICAL FLOOR PLAN (LIGHTING) SCALE: 1/4" = 1'-0" E2.0 Make a hatch on the N/A Area DESIGN TEAM: Y�m YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21 ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 FLOOR SINK &I ---- THREE COMPARTMENT SINK INDIRECT WASTE CONNECTION N.T.S. LAVATORY TRAP SANITARY PLUMBING FLOOR PLAN SCALE: 1/4" = 1'-0" TRAP PRIMER CONNECTION JONAS HAIES CO. 27033 TRAP RESEAL DETAIL N.T.S. TO •P" TRAP Iz / / / / within Hatched Area PLUMBING FIXTURE CONNECTION SCHEDULE ' AS PER FLORIDA PLUMBING CODE TABLE 604.4 & MDC ORDINANCE 8-14 Section 8-31 No. DESCRIPTION DRAIN WATER COLD HOT AIR VACUM SLOPE FU MAXIMUM WATER FLOW RATE` REMARKS SK SINK 1-1/2" 1/2" 1/2" — 1-1/2"@1/4"/FT 2 1.0 GPM — MSK MOP SINK 3" 1/2" 1/2" — 3"@1/8"/FT 3 1.0 GPM FD FLOOR DRAIN 3" 1/2" — 3"@1/8"/FT 3 PROVIDE 1/2" CW FOR TRAP RESEAL — FS FLOOR SINK 3" 1/2" — 3"@1/8"/FT 3 PROVIDE 1/2" CW FOR TRAP RESEAL — L LAVATORY 1-1/2" 1/2" 1/2" — 1-1/4"@1/4"/FT 1 0.5 GPM WC WATER CLOSET 4" 1" 4"@1/8"/FT 3 1.28 GPM UR URINAL 2" 3/4" N/A 1-1/2"@1/4!' FT 2 0.5 GPM WALL HUNG VALVE -TYPE WATER CONSEVATION TYPE, LESS THAN 1.0 GPF. TCH TREATMENT CHAIR 2" 1/2" WA 1/2" 1-1/2" 1-1/2"@1/4!7F7 2 0.5 GPM WALL HUNG VALVE -TYPE WATER CONSEVATION TYPE, LESS THAN 1.0 GPF. PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION — — — — — — — — EXISTING SANITARY LINE y VACUUM LINE PIPE UP CW COLD WATER - EXISTING WATER LINE A COMPRESSED AIR LINE I CO CLEANOUT HW HOT WATER - — — — — — — - VENT LINE WATER HAMMER ARRESTER FLOOR DRAIN FW FILTERED WATER SANITARY LINE GATE VALVE —a WATER CLOSET DRAIN A COMPRESSED AIR GW GREASE WASTE BACKFLOW PREVENTER P-TRAP HW HOT WATER - COLD WATER LINE GAS COCK VALVE & BALANCING VALVE NEW CONNECTION EXIST. EXISTING -- HOT WATER LINE HOSE BIBB 1 IN RECESSED METAL BOX) AAV AIR ADMITTANCE VALVE MIN. MINIMUM — —FW— - — FILTERED WATER LINE D PIPE DOWN FU FIXTURE UNIT TYP. TYPICAL DESIGN TEAM YAN L. SOLIS, P.E ELECTRICAL ENGINEER 14245 S.W. 21 ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 .�G� NAB •••.�• •ua••• •••••• •' YAN L. SOLIS - PE 75423 • """ NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS • ° ° ° ° u•u Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave #204 Miami FL 33137 MANAGMENT: # REVISIONS DATE �tvfi 5/27/2019 Q ev 6/18/2019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: 4 Rev Description: Bar Counter Top Details. Travel Distance From Bar Bar Opening Detail C:\Users an ro P2.0 DESIGN TEAM: 3PM GREASE RCEPTOR. IER GB-250 DETAIL.) PLAN FOR CONTINUATION (SHEET P1.0) SANITARY PLUMBING ISOMETRIC DIAGRAM N.T.S. YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21 ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 r�� OF FCC I").j it SOS/P PE 75423 .'�4 '�SSyONA��F�C''�, YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL STAMPS PROJECT: Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE zi ev 5/27/2019 DATE : 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: New Bar area layout New Electrical Panels SANITARY PLUMBING ISOMETRIC DIAGRAM SHEET No: P2.1 DESIGN TEAM: UNION (TYP) RELIEF VAL AIR GAP AS REQUIRED BY CODE 1/2" P&T RELIEF PIPE TO OUTSIDE BUILDING TERMINATE 6" ABOVE GRADE 3/4" HOT WATER PIPE GASINSTANT WATER HEATER S.O.V. (TYP) GAS PIPE COLD WATER PIPE GIWH-1: GAS INSTANT WATER HEATER "RinnaP' (OR APPROVED EQUIVALENT) MODEL NO. RUR98e, NATURAL GAS INPUT (MIN. 10,300 BTU & MAX. 199,000 BTU), 120V, 1.3A 1/60. FLOW RATE 7.5 GPM @ 70-F RISE, 5 YEAR WARRANTY. ENERGY FACTOR 0.59, DIMENSIONS 23" (HEIGHT) x 14" (WIDTH) X 9" (DEPTH), (U.L LISTED). NOTES: A. CONTRACTOR TO VERIFY MANUFACTURER SPECIFICATIONS. B. DO NOT INSTALL THIS TANKLESS: - UNDER AN OVERHANG LESS THAN 3 FEET FROM ITS TOP OR EAVES. - WHERE WATER, DEBRIS OR FLAMMABLE VAPORS MAY GET INTO THE FLUE TERMINAL. -A PIT OR LOCATION WHERE GAS AND WATER CAN ACCUMULATE. C. DO NOT INSTALL THE TANKLESS VENT TERMINATOR WITHIN 4 FT OF ANY AIR INTAKE OR BUILDING OPENING. D. DO NOT HAVE THE VENT TERMINAL POINTING TOWARD ANY OPENING INTO A BUILDING. GAS TANKLESS WATER HEATER PIPING 1DIAGF?AM N.T.S. kL ,DE L METER L- SERVICE MATERIALS ITEM QUANT DESCRIPTION 1 1 1" BACKFLOW PREVENTER ASSEMBLY 2 * 2 1" X NOM NIPPLES -BRASS OR COPPER 3 2 1" X 90% ELBOWS -BRASS OR COPPER 4 2 1" X VARIES RISER -BRASS OR COPPER 5 * PEA GRAVEL 6 * PLASTIC LINER STANDARD DOUBLE CHECK OR REDUCED PRESSURE BACKFLOW PREVENTER DETAIL N.T.S. ER LATING CKFLOW NTER 1-1/4"0 WATER SERVICE PIPE — SEE PLUMBING SITE V.. B. ' PLAN FOR CONTINUATION /ALVE (SHEET P1.0) PLUMBING FIXTURE CONNECTION SCHEDULE AS PER FLORIDA PLUMBING CODE TABLE 604.4 & MDC ORDINANCE 8-14 Section 8-31 No. DESCRIPTION DRAIN WATER AIR VACUM SLOPE FU MAXIMUM WATER FLOW RATE* REMARKS COLD HOT SK SINK 1-1/2" 1/2" 1/2" — 1-1/2"@1/4"/FT 2 1.0 GPM MSK MOP SINK 3" 1/2" 1/2" 3"@1/8"/FT 3 1.0 GPM FD FLOOR DRAIN T' 1/2" 3"@1/8"/FT 3 PROVIDE 1/2" CW FOR TRAP RESEAL FS FLOOR SINK 3" 1/2" 3"@1/8"/FT 3 PROVIDE 1/2" CW FOR TRAP RESEAL L LAVATORY 1-1/2" 1/2" 1/2" — 1-1/4"@1/4"/1FT 1 0.5 GPM WC WATER CLOSET 4" 1" 4"@1/8"/FT 3 1.28 GPM UR URINAL 2" 3/4" N/A 1-1/2"@1/4"/FT 2 0.5 GPM WATER CONSEVATIONALL HUNG PTYPE, LESS THAN 1.0 GPF. TCH TREATMENT CHAIR 2" 1/2" N/A 1/2" 1-1/2" 1-1/2"@1/4"/FT 2 0.5 GPM WALL HUNG VALVE -TYPE WATER CONSEVATION TYPE, LESS THAN 1.0 GPF. PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION - - - - - - - - EXISTING SANITARY LINE V VACUUM LINE PIPE UP CW COLD WATER - EXISTING WATER LINE --- ] CAPPED WATER LINE --{I CO CLEANOUT HW HOT WATER - - - - - - - - VENT LINE WATER HAMMER ARRESTER FLOOR DRAIN FW FILTERED WATER SANITARY LINE ----- GATE VALVE 0 WATER CLOSET DRAIN A COMPRESSED AIR GW GREASE WASTE --Gi�D­ BACKFLOW PREVENTER P-TRAP HW HOT WATER COLD WATER LINE GAS COCK VALVE & BALANCING VALVE iib NEW CONNECTION EXIST. EXISTING -- HOT WATER LINE HOSE BIBB ( IN RECESSED METAL BOX) AAV AIR ADMITTANCE VALVE MIN. MINIMUM FW- - FILTERED WATER LINE PIPE DOWN FU FIXTURE UNIT TYP. TYPICAL YCM YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 PE: 75423 SEAL: K, OF F(0'' ;' P ...................'f'O PE 755 223 q ' IN YAN YAN L. SOLIS - PE 75423 NOT VALID FOR GONSTRUC-101' OR BIDDING WITHOUT SIGNATURE & GL'r APPROVAL S,? BPS PROJECT: Sins Gastrobar Restaurant 9835 NE 2nd Ave Miami Shores FL 33138 Owner: 9801 Park LLC 4141 NE 2nd Ave # 204 Miami FL 33137 MANAGMENT: # REVISIONS DATE ,A 1 \ Rev SRev 't5 5/27/2019 1 \ ev j 6/18/2019 DATE: 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. SHEET TITLE: Rev Description: Bar Counter Top Details. Travel Distance From Bar Bar Opening Detail WATER PLUMBING FLOOR PLAN SHEET No: NOTES: *INSTALL UNION IS) TO FACILITATE REMOVAL / INSTALLATION INSTALLATION SHOWN ABOVE IS FOR A 1 1/2" SERVICE. CHANGE PIPING MATERIALS ACCORDINGLY FOR SERVICE SIZE XUsers\Yan\Droabox\2018\9801-9845 NE 2nd Ave Miami Shores FL 33138\New Restaurant\From Orlando\Bar Rev\PLUMB\P-1.dwa, 7/8/2019 9:22:37 AM, AutoCAD PDF (General Documentation).106 P3.0 DESIGN TEAM: Al 3/4"0 CW & i \' 1/2" HW \, IN WALL II I 3/4"0 CW 1/2" H\ IN WAL 3/4"0 CW & 1/2" HW YAN L. SOLIS, P.E. ELECTRICAL ENGINEER 14245 S.W. 21 ST TERRACE MIAMI, FL 33175 PH: (305) 484-5596 P E: 75423 SEAL: ' QF F(Q''- P......... PE 75423 v s/oNA`��G YAN L. SOLIS - PE 75423 NOT VALID FOR CONSTRUCTION OR BIDDING WITHOUT SIGNATURE & CITY APPROVAL Sl-Aml,a DESIGN TEAM: s ACCSESSIBLE SOLENOID SUPPRESSION SYSTEM G G2/2"�3)4"GAS ® jGjj PIPE FORBURNER#"BURNERH)(100,000 BTUIH)W4"GAS PIPE FOR24" BURNER(100,000 BTUIH) 3l4'GAS PIPE FOR FRYER 1-1/2" (50,000 BTUIH) �e '4" GAS PIPE FOR SALAMANDRA OVEN (30,0001TUIH) 3/4" 314"GAS PIPE FOR DOUBLE OVEN _ (50000 BTUIH) J O 0 O FL L 1 1/2" ==J1 -1/2" - TO TEMP GAS TANK 3/4" VALVE FOR TANKLESS -WATER HEATER (199,000 BTU/H) 31 2d c0 28`B4 G (D 3/4" \G 3/4" PROJECT: (7 ,I(f^ 3/4" Sir {lz� 3/4" GAS PIPE FOR 24" G IIll'' OLESS (7 BURNER#1 1-112" "l� WATER HEATER (0 13/4„ (100,000 BTU/H) (199,000 BTU/H) 983 of A 3/4" GAS PIPE FOR 24" U BURNER #2 TEE FITTING WITH CAP Miami 0I � 3/4" � (100,000 BTU/H) FOR PRESSURE MEASURING 1 �f a AND SEDIMENT TRAP.(TYP.) 3/4" GA PIPE FOR /G (D FRYER { 3/4" (50, 00 BTUH) 98 3/4" GAS PIPE FOR 43 6 G 4141 N GAS OVEN (D b (50,000 BTU/H) M i C 314" GAS PIPE FOR GAS OVEN (50,000 BTU/H) 1-1/2" NOTE: MANAGMENT: 3/4" GAS PIPE FOR CD . LOW PRESSURE GAS PIPE LONGEST= 140'-6" --- 773,000 BTU/H '�SALAMANDRA OVEN # REVI: (30,000 BTU/H) G GAS PIPING NOTES 1. PIPING MATERIAL SHALL BE (ASTM A53) TREATED ev 1 SCHEDULE 40 BLACK STEEL WITH MALLEABLE IRON FITTINGS (ANSI B16.3, A19.7), SIZED PER FBC, FG TABLE z Rev 1/2" FG402.4(28). G\ 2. INSTALL GAS PIPING IN ACCORDANCE WITH NFPA 58 AND TEST WITH PRESSURES AND TEST DURATIONS G ACCORDING TO NFPA 54. 3. APPLIANCES SHALL BE LISTED AND LABELED AS PER r FBC-FG-CH 301.3. SHEET TITLE: 1,000 GALLON UNDERGROUND PROPANE GAS TANK 1-1/2" —FIRST STAGE LOW PRESSURE REGULATOR U. L. GAS COCK VALVE (TYP.) UNION (TYP.) Gas Isometric Diagram SHEET No: C:\Users\Yan\Dropbox\2018\9801-9845 NE 2nd Ave Miami Shores FL 33138\New Restaurant\From 0rlando\Bar_Rev\PLUMB\P-1.dwg, 7/8/2019 9:26:47 AM, AutoCAD PDF (General Documentation).pc3 1' C9 f2A `3/ C7 �3/4" C0 3/4" /ryo � gC9J 20/ C7 dI 3/4" � 3/4" GAS PIPE FOR 24" BURNER #1 6 I 3/4" a (100,000 BTU/H) Qf 3/4" GAS PIPE FOR 24" (0 BURNER#2 �- 3/4" 3/4" GA PIPE FOR (100,000 BTU/H) of � 0 FRYER 3'4" 1 (50, 00 BTU/H) 3/4" GAS PIPE FOR GAS OVEN (50,000 BTU/H) 3/4" GAS PIPE FOR GAS OVEN (5Q000 BTU/H) 4" GAS PIPE FOR A Z,�G P,LAMANDRA OVEN (30,000 BTU/H) \C 1-1/2" �G\ `SG fia -1/2" 50,(6 0 N 1,000 GALLON UNDERGROUND PROPANE GAS TANK 1-1/2" ---3/4"GAS FOR TANKLESS hl WATER HEATER #2 ""000 BTU/H) TEE FITTING WITH CAP \` FOR PRESSURE MEASURING AND SEDIMENT TRAP.(TYP.) NOTE: LOW PRESSURE GAS PIPE LONGEST= 140'-6" ---- 773,000 BTU/H GAS PIPING NOTES 1. PIPING MATERIAL SHALL BE (ASTM A53) TREATED SCHEDULE 40 BLACK STEEL. WITH MALLEABLE IRON FITTINGS (ANSI B16.3, A19.7), SIZED PER FBC, FG TABLE FG402.4(28). 2. INSTALL GAS PIPING IN ACCORDANCE WITH NFPA 58 AND TEST WITH PRESSURES AND TEST DURATIONS ACCORDING TO NFPA 54. 3. APPLIANCES SHALL BE LISTED AND LABELED AS PER FBC-FG-CH 301.3. 1-1/2" —FIRST STAGE LOW PRESSURE REGULATOR —U.L. GAS COCK VALVE (TYP.) UNION (TYP.) TO TEMP GAS TANK 3/4" VALVE FOR TANKLESS WATER HEATER (199,000 BTU/H) Gas Isometric Delaqrar Vol'n a►Ii- mp DESIGN TEAM: MANAGMENT: # REVISIONS DATE 1 ev 1 5/27/2019 DATE : 5/13/2019 DRAWN BY: Y.S. CHECKED BY: Y.S. •1Y•O• a 1 °1•• • •y6•• •Y••Y• • • • ••• • ••• a• • • a •a•••• •••••• a a • J CR z m N CITY COPY 7�"2 L;io r5 VILLAGE _ E4aY'1..;::I°:� I?iPJFN7 --APrROvED DATE zo. F4G ? 'C URAL ELEGTRfCAL m t �' A611 - t Ulu".f•LIAE TH �L tiT Ar10C0 N-1'. czi v�j 1- JU 1 71019