CC-07-21-1868
Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2207 Fax: (305) 756.8972 BUILDING RECERTIFICATION Date: October 5, 2021 Permit No. CC-07-21-1868 To: Albert Mora 645 NE 92 St. Miami Shores, Florida 33138 Subject: 70 years Building/Electrical Recertification. Folio 11-3206-043-0001 645 NE 92 St. Miami Shores, Florida 33138 The Village of Miami Shores Building Department received and reviewed the Building Structure and Electrical System recertification report dated August 18, 2021 by Gordon W. Myers, P.E and Florida license number 36852. Based on the reports provided, the building on the above referenced property was found to be structurally and electrically safe for its continued use and occupancy. This Letter of Recertification is granted for the building on this property. The Recertification expires on the 80 year anniversary from original construction date. At that time, a new Recertification Report must be submitted to the Building Official. Although this Letter of recertification allows continued occupancy of the building, issuance of this letter does not preclude the Building Official from carrying out his responsibilities under Section 8-5 of the Code of Miami -Dade County. Further, issuance of this letter shall not be construed directly, or indirectly, as a guarantee of the safety of any portion of the structure. As per Miami Dade County Code Sec. 8-11. - Existing buildings. (a)The requirements contained in the Florida Building Code, shall apply to all buildings and/or structures now existing or hereafter erected. All buildings and/or structures and all parts thereof shall be maintained in a safe condition, and all devices or safeguards that are required by the Florida Building Code shall be maintained in good working order. Electrical wiring, apparatus and equipment, and installations for light heat or power and low voltage systems as are required and/or regulated by the Building Code, now existing or hereinafter installed, shall be maintained in a safe condition and all devices and safeguards maintained in good working order. Thank you for your cooperation in this matter. Sincerely, Ismael Naranjo, BO, CFM Building Director. Miami Shores Village \may Building De artment EP272021c� g p[FS a C0 \ 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 (� Tel: (30S) 795-2204 Fax: (305) 756-8972 - �/ INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ PLUMBING ❑ MECHANICAL ❑ PUBLIC WORKS FBC 20 o Master Permit NO.QC`0'� -2JvM� Sub Permit No ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS 'JOB ADDRESS: t4` S — "7 •� ��� City: Miami Shores Count • Miami Dade zip: Folio/Parcel#: j ' 3: L ` 00o I is the Building Historically Designated: Yes n.. 1-0 �— Occupancy Type: Load: Construction Type: Flood Zone: _ BFE: FFE: OWNER: Name (Fee Simple Titleholder): �t� �yt S �) ti'? G� �.t ' Phone#: `I 111— 3 10 Address: 6P kl s- A�lc ti S+V-4 City: A0U AA( 'S ti )I,Q ' State: �` i{ r72 i%�:� Zip: � 3)s Tenant/Lessee Name: jL Rl-411 ICUOA Phone#: Email: e/t/f Ga i en y'i CONTRACTOR: Company Name: Address: City Qualifier Name: State Certification or Registration #: DESIGNER: Architect/Engineer: ate: Phone#: Zip: Phone#: Certificate of Competency #: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: ��`� ��> DTI �1 C•� Specify color of color thru tile: Submittal Fee $ Scanning Fee $ Technology Fee $T Structural Reviews $ Permit Fee $ Radon Fee $ Training/Education Fee $ CCF DBPR $ CO/CC $ Notary $. Double Fee $ _ Bond $ TOTAL FEE NOW DUE $ 23,S7• p (Revised02/24/2014) Detail by Entity Name Page 1 of 3 FIwida 0-00arnen[ of Stale Ill gA!'lmmnl ai slate / DiviSiark of Ce+r ara[Inns / 3ear& RLeo7ras / Searr.Yt by EnILIV NilInki / Detail by Entity Name Florida Not For Profit Corporation SHORES PLAZA WEST CONDOMINIUM, INC. Fiiina Information Document Number 726431 FEI/EIN Number 59-1570223 Date Filed 05/17/1973 State FL Status ACTIVE Last Event REINSTATEMENT Event Date Filed 02/14/2011 Principal Address 637 N.E. 92ND ST 9C MIAMI SHORES, FL 33138 Changed: 03/02/2016 Mailing Address 637 N.E. 92ND ST 9C MIAMI SHORES, FL 33138 Changed: 03/02/2016 Registered Aaent Narne & Address Gomez, Marco A 637 NE 92nd St 9C Miami, FL 33138 Name Changed: 03/20/2018 Address Changed: 03/20/2018 Officer/Director Detail Name 8r Address Title Treasurer GOMEZ, MARCO DIVISION OF GORPOWIONS http: //search. sunbiz. org/Inquiry/CorporationSearchISearchRe sultDetail?inquirytype=Entity... 9/27/2021 Detail by Entity Name Page 2 of 3 637 N.E. 92nd St. Apt. 9C MIAMI SHORES, FL 33138 Title President Mora, Albert 645 NE 92nd St 14D Miami Shores, FL 33138 Title VP Salmon, Colin 637 NE 92nd St 11C miami, FL 33138 Title Secretary Giusti, Mariella 689 N.E 92nd St. 12G, FL 33138 Annual Reports Report Year Filed Date 2019 03/02/2019 2020 03/17/2020 2021 02/12/2021 Rocurrlent Images Q211212021 -ANNUAL RuPQRT View image in PDF format 03/17/2020 -- ANNUAL REPORT View image in PDF format U3r22,2US -- ANNUAPOR View image in PDF formal OV2012018 -- ANNUAL REPORT View image in PDF format 0210112017 - ANNUAL REPORT View image in F DF format 0310212 D76 -- ANNUAL R EP 0R T 02/11/2015 -- ANNUAL EPORT 113112D 14 --ANNUAL REPORT D312912D 13 - ANN.VAL RED{ 04112t2012 - ANNUAL REPORT 02/14/2011 - REINSTATEMENT 01/09i2009 -- ANNUAL Rom[ 4�1 4/2608 -• L REPORT 031t= 7 _ ANNUAL REPORT 011M2006 -ANNUAL REPORT 1114120 5 - ANNUALREP Q.R T 02:0212QD4 -- ANNUAL R PE_QR7 Q 111.W240s - • ANNUAL R FPORT 102k.1 3.,2002 --ANN AL R RT View image in PDF format View imaqe in PDF format View image in PDF format View Image in PDF forrttai view image in PDF format View image in PDF format View image in PDF format View image in PGF formal View image in PDF format View image in PDF format View image in PDF formai View image in PDF format View image in PDF formal View image in PGF format http: //search. sunbiz. org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entity... 9/27/2021 Detail by Entity Name Page 3 of 3 01111i2001 --ANNUAL REPORT View image in PDF format 02/0$i2000 -- ANNUAL,aLE0 T View image in PDF forinal 02F'24FS90.9--ANNUAL REPORT View image in PDF format 01/161100 — ANNVALfZ.EPQRT View image in PDF format F 9119DT — ANNUAL Rt -P R7 View image in PDF format 04!CW1996 -- ANNU,t1. REPORT View image in PDF format M10Ill 8$5 -- ANNUALREP RAT I View image in PDF formal �r:da OE[�a:-nleni n5 st—, Dlvmon If Cni pera Corr http://search. sunbiz.org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entity... 9/27/2021 TirOR.1DA ]ML?tLDER.S E\ CG I r E E R S I N. S P E C: T O R S "St r vii�c3 Flur ida Co._i _.L Lo Cv�js L" 8 7 7— R 9 4— 8 0 0 1 12555 Biscayne Blvd- # 934 North Miami, FL 33181 RE: Folio # 11-3206-043-0001 OWNER NAME: SHORES PLAZA WEST CONDO PROPERTY ADDRESS: 645 NE 92 ST MIAMI, FL 33138-2953 DATE OF INSPECTION: August 19, 2021 TO: CITY OF MIAMI SHORES BUILDING DEPARTMENT OFFICIAL On behalf of the above -mentioned property owner I would like to respectfully request that Recertification per Miami -Dade county Ordinance Miami -Dade County, Section 8- 1 l(f) be granted to the above -mentioned structure. I have inspected the above -mentioned property and find the building "structurally and electrically" safe for its use and present occupancy". As routine matter, in order to avoid possible misunderstanding, nothing in the report attached should be construed directly, or indirectly as a guarantee for any portion of the structure. Future function is not guaranteed in any way. To the best of my ability and knowledge this report represents an accurate appraisal of the present conditions of the building(s) based upon careful evaluation of the observed conditions, to the extent reasonably possible. Thank you for your attention to this matter. Sincerely 06rdon W. Myers PE Florida Builders, En A Professional En7 8-19-2021 2 & Inspectors, Inc. Firm CA 31260 Although this Letter of Recertification allows continued occupancy of the building, issuance of this letter should not be construed directly or indirectly as a guarantee of the safety/ code compliance of any portion of the structure. Cs> E\ G I\ E E R I 1 S P E C' T O R S "S r v i ig FI—ri,l— Lc 8 7 7- 8 9 4- 8 0 0 ll 12555 Biscayne Blvd_ # 934 North Miami, FL 33181 BUILDING DEPARTMENT MINIMUM INSPECTION PROCEDURAL GUIDELINES F-9R BUILDING'S ELECTRICAL RECERTIFICATION BUILDING DEPARTMENT INSPECTION COMMENCED INSPECTION MADE BY: DATE: 08-19-2021 Florida Builders Engineers & Inspectors Gordon W Myers PE 36852 /CA 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 08-19-2021 North Miami, Florida 33181 Tel: (305) 895-8001/ Fax: (305) 895-7001 Name of Title: SHORES PLAZA WEST CONDO Street Address: 621,629,637,645,657,673,689 NE 92 ST MIAMI, FL 33138-2953 Legal Description: SHORES PLAZA WEST CONDO MIAMI SHORES SEC 3 PB 10- 37 LOTS 14 THRU 20 BLK 63 Owner's Name: SHORES PLAZA WEST CONDO Owner's Mailing Address: 645 NE 92 ST UNIT 14-D MIAMI, FL 33138-2953 Folio Number of Building: 11-3206-043-0001 Building Code Occupancy Classification: 0407 RESIDENTIAL - TOTAL VALUE: CONDOMINIUM - RESIDENTIAL Present Use: WAREHOUSE / OFFICE / STORAGE PRINTING COMPANY General Description, Type of Construction, Size, Number of Stories, Features: 2 STORIES /CBS (2) STORY TOTAL 28 UNITS AND ADJ. AREA VARY BY UNIT SQ FT ACCORDING TO P. REC ►A GUIDELINES AND INFORMATION FOR RECERTIFICATION OF ELECTRICAL SYSTEMS OF FORTY(40) YEAR STRUCTURES j 1. ELECTRIC SERVICE 1. Size: Amperage 28 (100) Fuses ( X ) Breakers (XJ 2. Phase: Three Phase ( ) Single (X) 3. Condition: Good ( ) Fair ( X) Needs Renair ( ) 4. Comments: MAIN DISCONNECT LOCATED AT METER IK.00N( OF EACH BUILDING IN SETS OF 4 MAIN DISCONNECTS. SOME ARE BREAKERS AND SOME ARE FUSE ELECTRICAL PANELS/ ELEMENTS HAVE WEAR DUE TO AGE AND USE; HOWEVER THEY ARE OPERABLE AT THIS TIME AND IN FAIR CONDITION. CONTINUED MAINTENANCE IS SUGGESTED TO ENSURE PROPER AND CONTINUED OPERATIONS. UN -EXPOSED ELECTRICAL ELEMENTS WERE NOT INSPECTED; ONLY THOSE ELEMENTS THAT WERE VISBLE AT THE TIME OF THE INSPECTION WERE INSPECTED 2. METER AND ELECTRICAL ROOM: 1. Clearance: Good ( ) Fair ( X ) Requires Correction( ) 2. Comments: METER ROOM PRESENT AT THIS BUILDING 3. GUTTERS 1. Location: Good (X) Requires Repair ( ) 2. Taps and fill: Good (X) Requires Repair ( ) 4. ELECTRICAL PANELS 1. Panel # (1- 28) Location: INSIDE EACH UNIT 2. Panel # ( ) Location: 3. Panel # ( ) Location: 4. Panel # ( ) Location: 5. Panel # ( ) Location: 6. Panel # ( ) Location: 7. Panel # ( ) Location: 8. Panel # ( ) Location: Conditions: Good (X ) Requires Repairs ( ) Comments: 8-19-2021 3 I 5. BRANCH CIRCUITS 1. Identified: Yes (X) Must be identiilea ( ) 2. Conductor: Good (X ) Deteriorated ( ) Must be Replan--d ) 3. Comments: 6. GROUNDING OF SERVICE Condition: Good (X ) Repairs Requires? ) Comments: 7. GROUNDING OF EQUIPMENT Condition: Good (X ) Repairs Required ( ) Comments: 8. SERVICE CONDUITS/RACEWAYS Condition: Good (X ) Repairs Required ( ) Comments: 9. SERVICE CONDUCTORS AND CABLES Condition: Good ( X ) Repairs Required ( ) Comments: 10. TYPES OF WIRING METHODS Condition: Conduit Raceways: Good (X ) Conduit PVC: Good (X) NM Cables: Good ( ) BX Cables: Good ( ) 11. FEEDER CONDUCTORS Condition: Good ( X ) Comments: 12. EMERGENCY LIGHTING Condition: Good (X) Comments: Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) 13. BUILDING EGRESS ILLUMINATION Condition: Good ( X) Repairs Required ( ) Comments: 14. FIRE ALARM SYSTEM Condition: Good ( ) Comments: N/A Repairs Required ( ) 15. SMOKE DETECTORS Condition: Good ( X ) Comments 16. EXIT LIGHTS Condition: Good (X ) Comments: 17. EMERGENCY GENERATOR Condition: Good ( ) Comments: N/A Repairs Required ( ) Repairs Required ( ) Repairs Required ( ) 18. WIRING IN OPEN OR UNDER COVER PARKING GARAGE AREAS Condition: Good (X) Repairs Required ( ) Comments: 19.OPEN OR UNDERCOVER PARKING SURFACE AND SECURITY LIGHTING Condition: Good (X) Repairs Required ( ) Comments: 20. SWIMMING POOL WIRING Condition: Good ( ) Repairs Required ( ) Comments: N/A 21. WIRING OF MECHANICAL EQUIPMENT Condition: Good (X ) Repairs Required ( ) Comments: GENERAL ADDITIONAL COMMENTS: Continued maintenance is suggested to maintain proper function. Inspection is made to what is readily visible and accessible only. AS A ROUTINE MATTER, AND IN ORDER TO AVOID POSSIBLE MUSUNDERSTANDING NOTHING IN THIS INSPECTION REPORT FORM ATTACHED MINIMUM INSPECTION GUIDELINES AND OUR NON-DESTRUCTIVE OBSERVATION SHOULD BE CONSTRUED DIRECTLY OR INDIRECTLY, AS A GUARANTEE OR WARRANTEE OF ANY PORTION OF THE STRUCTURE. TO THE BEST OF MY KNOWLEDGE AND ABILITY THIS REPORT REPRESENTS AN ACCURATE APPRAISAL OF THE PRESENT CONDITION OF THE STRUCTURE BASED UPON CAREFUL EVALUATION OF THE OBSERVED CONDITIONS TO THE EXTENT REASONABLY POSSIBLE. PURSUANT TO SECTION 558.0035, FLORIDA STATUTES, AN INDIVIDUAL EMPLOYEE OR AGENT MAY NOT BE HELD INDIVIDUALLY LIABLE FOR NEGLIGENCE. 5 IEE\ G I \' E E R S Jam- 1\ S P E C T O4W R S "Sc�,viroc7 Floricizi Go.asl 8 7 7- 8 9 4- 8 0 0 1 12555 Biscayne Blvd- # 934 North Miami, FL 33181 BUILDING DEPARTMENT MINIMUM INSPECTION PROCEDURAL GUIDELIN,'41S FOR BUILDING'S STRUCTURAL RECERTIFICATION BUILDING DEPARTMENT INSPECTION COMMENCED INSPECTION MADE BY: DATE: 08-19-2021 Florida Builders Engineers & Inspectors Gordon W Myers PE 36852 /CA 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 08-19-2021 North Miami, Florida 33181 Tel: (305) 895-8001/ Fax: (305) 895-7001 Name of Title: SHORES PLAZA WEST CONDO Street Address: 621,629,637,645,657,673,689 NE 92 ST MIAMI, FL 33138-2953 Legal Description: SHORES PLAZA WEST CONDO MIAMI SHORES SEC 3 PB 10- 37 LOTS 14 THRU 20 BLK 63 Owner's Name: SHORES PLAZA WEST CONDO Owner's Mailing Address: 645 NE 92 ST UNIT 14-D MIAMI, FL 33138-2953 Folio Number of Building: 11-3206-043-0001 Building Code Occupancy Classification: 0407 RESIDENTIAL - TOTAL VALUE: CONDOMINIUM - RESIDENTIAL Present Use: WAREHOUSE / OFFICE / STORAGE PRINTING COMPANY General Description, Type of Construction, Size, Number of Stories, Features: 2 STORIES /CBS (2) STORY TOTAL 28 UNITS AND ADJ. AREA VARY BY UNIT SQ FT ACCORDING TO P. REC 8-19-2021 1�� ADDITIONS TO ORIGINAL STRUCTURE: No visible additions noted to original structure at this time. This determination is made on what is vis_blc and accessible at the site with no inquiry to construction plans and or microfilms. 2. PRESENT CONDITION OF STRUCTURE a. General alignment (not good, fair, poor, explain if significant) FAIR 1. Bulging MINOR STRUCTURAL EXPANSION THAT IS TYPICAL FOR THIS I Y P E GI, STRUCTURE DOES NOT WARRANT REPAIRS AT THIS TIME 2. Settlement TYPICAL AND MINOR DOES NOT WARRANT STRUCTURAL REPA=RS r.T THIS TIME STRUCTURAL CONDITIONS ARE FUNCTIONAL AT THIS TIME 3. Defections NOT OF STRUCTURAL SIGNIFICANCE 4. Expansion TYPICAL MINOR EXPANSION NOT WARRANTED FOR REPAIRS AT THIS TIME 5. Contraction TYPICAL MINOR CONTRACTION NOT WARRANTED FOR REPAIRS AT THIS TIME. b. Portions showing distress (note beams, columns, structural walls, floors, roofs) NONE VISIBLE C. Surface conditions- describe general conditions offinishes, cracking, spalling, peeling signs of moisture penetration & stains: FAIR NOT WARRANTED FOR REPAIRS AT THIS TIME d. Cracks- note location in significant members. Identify crack size as HAIRLINE if barely dissemble; FINE if less than 1 mm in width; MEDIUM if between land 2 mm in width; WIDE if over 2 mm. FINE/ NOT WARRANTED STRUCTURAL REPAIRS AT THIS TIME e. General extent of deterioration — cracking or spalling of concrete or masonry; oxidation of metals; rot or borer attack in wood. N/A f. Previous patching or repairs: YES g. Nature of present loading; indicate Residential. Commercial, other magnitude. 3. INSPECTIONS a. Date of notice of required inspection: 2021 b. Date(s) of actual inspection: 8-19-2021 C. Name and qualification of individual submitting report: Gordon W. Myers PE 36852 d. Description of any laboratory or other formal testing, if required, rather than manual or visual procedures: N/A e. Structural repair note appropriate line: 1. None Required XXXXXXX 2. Required (describe and indicate acceptance) 4. SUPPORTING DATA a. N/A b. - WA-C. N/A Sheet written data Photographs Drawings or sketches 5. MASONRY BEARING WALL = Indicate good, fair, poor on appropriate lines a. Concrete masonry units: FAIR b. Clay tile or terracotta units: FAIR C. Reinforced concrete tile columns: FAIR d. Reinforced concrete tile beams: FAIR e. Lintel: FAIR f. Other type bond beams FAIR g. Masonry finishes — exterior FAIR 1. Stucco FAIR 2. Veneer N/A 3. Paint Only FAIR 4. Other (describe) fd 5. MASONRY BEARING WALL (con't) h. Masonry finishes — interior FAIR 1. Vapor barrier NONE 2. Furring and Plaster FAIR 3. Paneling FAIR 4. Paint Only FAIR 5. Other (describe) i. Cracks: TYPICAL CONTRACTING & EXPANDING CRACKING NOTED 1. Location - note beams, columns, other 2. Description: NOT WARRANTED TO JUSTIFY REPAIRS AT THIS TIME j. Spalling: NONE VISIBLE 1. Location - note beams, columns, other 2. Description N/A k. Rebar corrosion- check appropriate line: 1. None visible XXXX 2. Minor — patching will suffice 3. Significant —but patching will suffice 4. Significant— structural repairs required 1. Samples chipped out for examination in spall areas 1. NO XXXX 2. YES — describe color texture, aggregate, and general quality 6. FLOOR AND ROOF SYSTEM a. Roof.. 1. Describe (flat, slope, type roofing, type roof deck, conditions HIP ROOF [WOOD DECKING. ROOF IS WATER TIGHT AT THIS TIME 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment and conditions of support: FAIR 3. Note types of drains and scupper and condition of cooling towers, air conditioners: DRAINAGE TO PERIMETER OF ROOF b. Floor system (a): 1. Describe (type of system framing, material, spans, condition) CRAWL/ FAIR c. Inspection — note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members: ALL ACCESSIBLE AREAS WERE INSPECTED. 7. STEEL FRAMING SYSTEM a. Description NO STEEL FRAMING CBS b. Exposed Steel — describe condition of paint & degree of corrosion SATISFACTORY AT THIS TIME c. Concrete or other fireproofing — note any cracking or spalling, and note where any covering was removed for inspection NONE d. Elevator sheave beams & connections and machine floor beams — note condition: N/A -2021 g 8. CONCRETE FRAMING SYSTEM a. Full description of structural system CBS STRUCTURE b. Cracking 1. Not Significant XXXX TYPICAL /EXPANSION AND CONTRACTION CRACKING NOTED AT I HIS TIME 2. Location and description of members affected and type cracking c. General condition FAIR d. Rebar corrosion - check appropriate line: 1. Non visible XXX 2. Location and description of members affected and type cracking 3. Significant —but patching will suffice 4. Significant— structural repairs required (describe) e. Samples chipped out in spall areas: 1. No XXXX 2. Yes, describe color, texture, aggregate, general quality: 9. WINDOWS a. Type (Window, steel, aluminum, jalousie, single hung, double hung, casement, awning, pivoted, fixed, other) ALUMINUM b. Anchorage — type & condition of fasteners and latches. SCREWED INTO WINDOW BUCKS c. Sealant —type of condition of perimeter sealant & at mullions: TYPICAL CHAULKING AT FRAMES AND GASKETING AT GLAZING d. Interior seals — type & condition at operable vents: GASKETING AT GLAZING e. Conditions: SATISFACTORY ST THIS TIME 10. WOOD FRAMING a. Type — fully describe if mill construction, light construction, major spans, trusses, THE ROOF ARE FRAMED WITH DIMENSIONAL RAFTERS AND JOISTS FRAMING LIMITED ACCESS TO VIEW NOTED. b. Note metal fitting i.e., angles, plates, bolts, split pintles, other, and note condition: METAL FITTING IN FUCTIONAL CONDITIONS/ LIMITED ACCESS c. Joints —note if well fitted and still closed: FAIR CONDITIONS / LIMITED VIEW d. Drainage —note accumulations of moisture: FAIR ROOF DRAINS TO PERIMETER e. Ventilation —note any concealed spaces not ventilated: ATTIC TYPICALLY VENTED WITH PERIMETER SOFFIT VENTS f. Note any concealed spaces opened for inspection: NONE/ ALL AREAS AVAILABLE WERE ACCESSED 11. GENERAL ADDITIONAL COMMENTS: THIS REPORT DOES NOT REFLECT ANY POTENTIAL VIOLATIONS THAT MAY BE PRESENT ON THE BUILDING. THIS IS ONLY AN INSPECTION OF THE VISUAL CONDITIONS FOUND DURING OUR INSPECTION. Continued maintenance is suggested to maintain proper function. Inspection is made to what is readily accessible and visible only. AS A ROUTINE MATTER, AND IN ORDER TO AVOID POSSIBLE MUSUNDERSTANDING NOTHING IN THIS INSPECTION REPORT FORM ATTACHED MINIMUM INSPECTION GUIDELINES AND OUR NON-DESTRUCTIVE OBSERVATION SHOULD BE CONSTRUED DIRECTLY OR INDIRECTLY, AS A GUARANTEE OR WARRANTEE OF ANY PORTION OF THE STRUCTURE. TO THE BEST OF MY KNOWLEDGE AND ABILITY THIS REPORT REPRESENTS AN ACCURATE APPRAISAL OF THE PRESENT CONDITION OF THE STRUCTURE BASED UPON CAREFUL EVALUATION OF THE OBSERVED CONDITIONS TO THE EXTENT REASONABLY POSSIBLE. THIS REPORT DOES NOT REFLECT ANY POTENTIAL VIOLATIONS THAT MAY BE PRESENT ON THE BUILDING. THIS IS ONLY AN INSPECTION OF THE VISUAL CONDITIONS FOUND DURING OUR INSPECTION. IF A VIOLATION EXISTS THEN THIS REPORT IS INVALID. PURSUANT TO SECTION 558.0035, FLORIDA STATUTES, AN INDIVIDUAL EMPLOYEE OR AGENT MAY NOT BE HELD INDIVIDUALLY LIABLE FOR NEGLIGENCE. 9 � II // [ q� 1-:;1 9- 4DO IX II "AL 13 .t T I I -1:> U- W E\ G I \' E E IR 6 S 1\ S P E C T O Ii S "'Sc>rvi rxy Flc�ridzx Cc>..xsl Lc> Coaxs�" 8 7 7- S 9 4- 8 0 0 1 12555 Biscayne Blvd_ # 934 North Miami, FL 33181 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMIISATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI-.9A!)L COUNTYAND OUTDOOR LIGHTING OVERSPILLING SECTION 33-4.1 OF THE CODE OF MIAMI DADE COUNTY INSPECTION COMMENCED INSPECTION MADE BY: DATE: 08-19-2021 Florida Builders Engineers & Inspectors Gordon W Myers PE 36852 /CA 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 08-19-2021 North Miami, Florida 33181 Tel: (305) 895-8001/ Fax: (305) 895-7001 Name of Title: SHORES PLAZA WEST CONDO Street Address: 621,629,637,645,657,673,689 NE 92 ST MIAMI, FL 33138-2953 Legal Description: SHORES PLAZA WEST CONDO MIAMI SHORES SEC 3 PB 10-37 LOTS 14 THRU 20 BLK 63 Owner's Name: SHORES PLAZA WEST CONDO Owner's Mailing Address: 645 NE 92 ST UNIT 14-D MIAMI, FL 33138-2953 Folio Number of Building: 11-3206-043-0001 Building Code Occupancy Classification: 0407 RESIDENTIAL - TOTAL VALUE: CONDOMINIUM - RESIDENTIAL Present Use: WAREHOUSE / OFFICE / STORAGE PRINTING COMPANY General Description, Type of Construction, Size, Number of Stories, Features: 2 STORIES /CBS (2) STORY TOTAL 28 UNITS AND ADJ. AREA VARY BY UNIT SQ FT ACCORDING TO P. REC The undersigned states the following: 1. I am a Florida registered professional engineer with an active license. 2. On August 19, 2021, at 9PM I measured the level of illumination in the parking lot(s) serving the above referenced building. 3. Maximum 4.6 foot candle per SF, Minimum 2.0 foot candle per SF, Minimum to Maximum ratio 2.6, foot candle, 3.30 average per SF. 4. The level of illumination provided in the parking lot(s) meet the minimum standards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. 5. The level of outdoor lighting overspill meets the limitations established in Section 33-4.1 of the Code of Miami Dade County. Gordon W. Myers PE 36852 Florida Builders, Engineers & Inspectors, Inc. A Professional Engineering Firm CA 31260 -to-xaal 10 ll Electrical wiring, apparatus and equipment, and installations for light heat or power and low voltage systems as are required and/or regulated by the Building Code, now existing or hereinafter installed, shall be maintained in a safe condition and all devices and safeguards maintained in good working order. A building re -certification report signed and sealed by the Florida license engineer and or Architect along with the required fees shall be submitted to this office within thirty (90) days of receiving this notice. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305-795-2204. Sincerely, J7/rJJ-'dt'-( Ismael Naranjo, BO Building Director Email: bo@msvfl.gov Sent via USPS regular and certified mail # 7020-2450-0000-4634-2810 7020-2450-0000-4634-7434 Miami Shores Village Building Department 10050 N.E. 2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Notice of Required 70 year Building Recertification Date: July 19, 2021 To: SHORES PLAZA WEST CONDOMINIUM INC 621 NE 92 ST MIAMI SHORES, FL 33138-2956 Re: 621 NE 92 ST MIAMI SHORES, FL 33138-2956 Dear Owner: According to the information provided by the Miami Dade County Property Appraisers office the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8-11, the subject property must be inspected and re -certified by a Florida license architect or engineer. Sec. 8-11. - Existing buildings. a) The requirements contained in the Florida Building Code, covering the maintenance of buildings, shall apply to all buildings and/or structures now existing or hereafter erected. All buildings and/or structures and all parts thereof shall be maintained in a safe condition, and all devices or safeguards that are required by the Florida Building Code shall be maintained in good working order. Electrical wiring, apparatus and equipment, and installations for light heat or power and low voltage systems as are required and/or regulated by the Building Code, now existing or hereinafter installed, shall be maintained in a safe condition and all devices and safeguards maintained in good working order. A building re -certification report signed and sealed by the Florida license engineer and or Architect along with the required fees shall be submitted to this office within thirty (90) days of receiving this notice. If you would like a copy of Minimum Inspection Procedural Guidelines for Structural and Electrical Recertification, or if you have any questions, please call my office at 305-795-2204. Sincerely, Ismael Naranjo, BO Building Director Email: bo@msvfl.gov Sent via USPS regular and certified mail # 7020-2450-0000-4634-2810 7020-2450-0000-4634-7434 E IE 7_ I \ I % �LnlEi� 4W \ C. I �' E 1 R 8 3�- S P E C T O R S " S c- w i n g F 1 <., r i cA er C o .,i e, l t ca 8 7 7— 8 9 4— 8 0 0 1 12555 Biscayne Blvd- # 934 North Miami, FL 33181 CERTIFICATION OF COMPLIANCE WITH PARKING LOT GUARDRAILS RE UIREMENTS IN CHAPTER 8C OF THE CODE OF MIAMI-DAW,, Q)i.NTY INSPECTION COMMENCED INSPECTION MADE BY: DATE: 08-19-2021 Florida Builders Engineers & Inspectors Gordon W Myers PE 36852 /CA 31260 INSPECTION COMPLETED 12555 Biscayne Blvd #934 DATE: 08-19-2021 North Miami, Florida 33181 Tel: (305) 895-8001/ Fax: (305) 895-7001 Name of Title: SHORES PLAZA WEST CONDO Street Address: 621,629,637,645,657,673,689 NE 92 ST MIAMI, FL 33138-2953 Legal Description: SHORES PLAZA WEST CONDO MIAMI SHORES SEC 3 PB 10-37 LOTS 14 THRU 20 BLK 63 Owner's Name: SHORES PLAZA WEST CONDO Owner's Mailing Address: 645 NE 92 ST UNIT 14-D MIAMI, FL 33138-2953 Folio Number of Building: 11-3206-043-0001 Building Code Occupancy Classification: 0407 RESIDENTIAL - TOTAL VALUE: CONDOMINIUM - RESIDENTIAL Present Use: WAREHOUSE / OFFICE / STORAGE PRINTING COMPANY General Description, Type of Construction, Size, Number of Stories, Features: 2 STORIES /CBS (2) STORY TOTAL 28 UNITS AND ADJ. AREA VARY BY UNIT SQ FT ACCORDING TO P. REC The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. On August 19, 2021 1 inspected the parking lots servicing the above referenced building for compliance with Section 8C-6 and determined the following (check only one): The narking lolls] is not adiacent to or abutIinv n can a1. tale or other hods of water. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are not protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. I have advised the property owner that he/she must obtain a permit for the installation of the guardrail and obtain all required inspection approvals to avoid enforcement action. Gordon W. Myers PE 36852 Florida Builders, Engineers & Inspectors, Inc. A Professional Engineering Firm CA 312fig II 1'•4�.1932 Miami Shores Shores Village Building Department l=ll' 10050 N.E. 2nd Avenue -_ Miami Shores, Florida 33138 "r 40 �O RW Tel: (305) 795.2204 Notice of Required 70 year Building Recertification Date: July 19, 2021 To: SHORES PLAZA WEST CONDOMINIUM INC 637 NE 92 ST 9C MIAMI SHORES, FL 33138 Re: 621 NE 92 ST MIAMI SHORES, FL 33138-2956 Dear Owner: According to the information provided by the Miami Dade County Property Appraisers office the above referenced property has a building or structure that is forty (40) years old or older. In accordance with Miami -Dade County Chapter 8 Section 8-11, the subject property must be inspected and re -certified by a Florida license architect or engineer. Sec. 8-11. - Existing buildings. a) The requirements contained in the Florida Building Code, covering the maintenance of buildings, shall apply to all buildings and/or structures now existing or hereafter erected. All buildings and/or structures and all parts thereof shall be maintained in a safe condition, and all devices or safeguards that are required by the Florida Building Code shall be maintained in good working order. J d -:I- m Domestic Mail Only :I For delivery information, visit our website at o,,v)6,.,-L1SpS.COr tti CO Certified Mail Fee Lr) 'S - ;Extra Services & Fees (check box, add fee as appropriate) ❑ ReturnReceipt (hardcopy) $ O ❑ Return Receipt (electronic) $ Postmark I= ❑ Certified Mall Restricted Delivery $ Here C3 [-]Adult Signature Required $ ❑ Adult Signature Restricted Delvery$ Postage p rl-_ S Er ru TOW Postage end Fees a uz c C3 rs t. :; or P - -o - ..... ... . Postal o CERTIFIED MAIU RECEIPT r-1 Domestic co 1J Certlfled Mall Fee S Mies& eU5 p+fato Prack box, add teens .�AWey 0 ©Rotum Aacafpt (hordcopw $- 0 ❑Rolum Receipt {elecwnry;] $ O ❑CQM'N u Mall Reelrlcted Detivay $ - Postmark C3 ❑Adull SignaLlre Raqulmd $ Here ❑Adult Skr wtm ROctrkied DeiWory S 0 PO"e S $ iL iota! Po"a and Foes O $