Loading...
RC-09-21-2269 COMPACTION TESTIQ, C—Oct — 21--' AJ(e S GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASHESTOS I ROOF TESTING 1 INSPECTION SERVICES I DRILLING SERVICES C- DYNATECH ENGINEERING CORP. W W W. DYNATECHEN GINEERING.COM MOISTURE —DENSITY RELATIONS OF SOILS —PROCTOR COMPACTION TEST DATE: April 29, 2022 CLIENT: DISTINCTIVE HOMES PROJECT: Proposed Addition (cry ADDRESS: 465 Grand Concourse, Miami Shores, FL CONTRACTOR: Distinctive Homes MATERIAL DESCRIPTION: Gray sand SAMPLED BY: WD TEST RESULTS Sample Number I TESTED BY: WD The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE 5.0 6.1 7.9 12.2 DRY DENSITY Optimum Moisture 9.2 Percent 100% Maximum Dry Density 105.8 lbs./cu.ft. % Passing'/4" Sieve 96 Percent 107 105 103 101 99 97 Sampled By: WD j j I I I T+ j Tested By: WD Checked By: WN v►�►t►ltitllt►r►►►► 4 6 8 10 12 14 P�, SArAD �,ri�`�. Respectively submitted, As a mutual protection to clients, the public and ourselves, all reports �G]; • �. E' '•. �q :_ are submitted as the confidential property of clients, and authorization 7 yt ;1 for use, publication of statements, conclusions or extracts from or regardingk r N0• 39584 '. * "Wissasn Na ani, P.E. our reports is reserved pending our written approval. EDYNATECH ENGINEERING CORP. STATE OF : �� Florida Reg. No. 39584 �v Certificate of Authorization No.: CA 5491 Q L Ss�oNA--a,,,, 100.2 102.7 104.5 103.1 D R Y D E N S I T Y GEOTECHNICAL 1 ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES _o Ec DYNATECH ENGINEERING CORP. W W W MYNATECHENGINEERING_ COM FIELDMENSITY TEST OF COMPACTED SOILS DATE: April 29 2022 CLIENT: DISTINCTIVE HOMES PROJECT: Proposed Addition ADDRESS: 465 Grand Concourse. Miami Shores. FL CONTRACTOR: Distinctive Homes Test No. 1 Location: West side of addition footers Test No. 2 Location: East side of addition footers Test No. 3 Location: North side of addition footers Test No. Location: Test No. Location: Description of Material: Gray sand TEST NO. 1 2 3 DEPTH 12" 12" 12" FIELD DENSITY 104.2 104.6 104.4 MOISTURE CONTENT % 7.0 7.4 7.2 MAX. DENSITY IN THE FIELD % 98.5 98.9 98.7 COMPACTION REQUIREMENTS % OF MAXIMUM DENSITY 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 105.8 1 105.8 105.8 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS sAAD Tested By: WD `,,`�R::'�.-qf'`'% Respectfully Submitted, Checked By: )AN * ; No. 39584 •: * - Wissam Naamani, P.E. * DYNATECH ENGINEERING CORP. :` STATE OF ; � Florida Reg. No. 39584 �1D �. `���: Certificate of Authorization No.: CA 5491 f, ss7 *A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval.