RC-09-21-2485 MISCGEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES t-Ek DYNATECH ENGINEERING CORP. W W W.DYNATECHENGINE£RING. COM MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: March 8. 2022 CLIENT: UNIVERSAL US CONSTRUCTION, INC. PROJECT: Proposed Residence ADDRESS: 1202 NE 93r6 Street Miami Sllores FL 33138 CONTRACTOR: Universal US Construction. Inc. MATERIAL DESCRIPTION: Tan sand Wrock fragments SAMPLED BY: JA TESTED BY: JA TEST RESULTS Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE DRY DENSITY 3.9 108.1 6.1 111.8 8.6 113.7 116 11.7 112.8 114 112 Optimum Moisture 114.2 Percent 100% Maximum Dry Density9.9 lbs./cu.ft. 110 % Passing %" Sieve 74 Percent 108 Sampled By: WD 106 Tested By: WD II + I I 1 ' Checked By: WN ��,t�t+tttttlrl�4 6 8 10 12 14 ,,LL SAAD ,y.., As a mutual protection to clients, the public and ourselves, all reports=.`�.pM �1 G E jll �rrf Respectively sttbmited, are submitted as the confidential property of clients, and authorization _ for use, publication of statements, conclusions or extracts from or red artiZnk ; No. 395Bd ; * Wissam Na tnani, P.E. our reports is reserved pending our written approval. = * =DYNATECH ENGINEERING CORP. STATE of =Florida Reg. No. 39584 �' _ - Certificate of Authorization No.: CA 5491 ,,��•� •F4OR1�P•G� :. 5S/0 •" N 11r,+tNA� r,0'' D R 0 0 GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES Lf t-PEC DYNATECH ENGINEERING CORP. W WW.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 8.2022 CLIENT: UNIVERSAL US CONSTRUCTION INC. PROJECT: Pra osed Residence ADDRESS: 1202 NE 93rd Street,Miami Shores FL 33138 CONTRACTOR: Universal I Iq Construction, Inc. Test No. 1 Location: East side of residence ad 1" lift Test No. 2 Location: Center of residence 12ad, IS,lift Test No. 3 Location: West side of residence nad, 1" lift Test No. 4 Location: North side of residence pad, 2nd lift Test No. 5 Location: Center of residence ad 2" Iift Description of Material: Tan sand wlrock fragments TEST NO. 11 2 3 4 DEPTH 12" 12" 12" 12" 12" FIELD DENSITY 112.9 112.5 112.7 113.0 112.4 MOISTURE CONTENT % 8.6 9.0 8.8 8.4 8.8 MAX. DENSITY IN THE FIELD % 98.9 98.5 98.7 98.9 98.4 COMPACTION REQUIREMENTS % OF MAXIMUM DENSITY 98% 98% 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 114.2 114.2 114.2 114.2 114.2 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION RE UIREMENTS Tested By: WD Checked By: WN ��s t r<� �1,t n � unr►►t► ��.�` Cam, -•�G E ••. •q / Respectfully Submitted, -. . f tN No. 39584 _ Wissa aamani, P.E. * — DYNATECH ENGINEERING �.O STATE OF rr� Florida Reg. No. 39584 ','per �. A,•; %,�►` Certificate of Authorization No. .� 0 RSA /,f�rsS70 L fxrrraIttf,It 0 *A density test determines th d f CORP. CA 5491 e egree o compactron of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES tEcD DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 8.2022 CLIENT: UNIVERSAL US CONSTRUCTION INC. PROJECT: Proposed Residence ADDRESS: 1202 NE 93rd Street Miami Shores FL 33138 CONTRACTOR: Universal US Construction Inc. Test No. 6 Location: South side of residence pad, 2nd lift Test No. Location: Test No. Location: Test No. Location: Test No. Location: Description of Material: Tan sand wlrock fragments TEST NO. 6 DEPTH 12" FIELD DENSITY 112.7 MOISTURE CONTENT % 8.7 MAX. DENSITY IN THE FIELD % 98.7 COMPACTION REQUIREMENTS 98% % OF MAXIMUM DENSITY 100% MAXIMUM DENSITY (LAB) 114.2 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS ���EttttattrrryJr Tested By: WD �.� D s^lJl f`'�i Checked BW y: N `��.��a• I.�Cf ks;•%,� Respectfully Submitted, No. 39584 Wissam Naamani, P.E. * = DYNATECH ENGINEERING CORP. STATE OF :'4 Florida Reg. No. 39584 Certificate of Authorization No.: CA 5491 -A density test determines the degree of compaction of the tested layer of material only, In noway shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. GEOTECHNICAL I ENVIRONMENTAL_L_MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES } -DEG DYNATEGH ENGINEERING CORP. W W W. DYNATECHENGINEERING. COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 8 2022 CLIENT: UNIVERSAL US CONSTRUCTION. INC. PROJECT: Pro used Residence (& ADDRESS: 1202 NE 93rd Street Miami Shores FL 33138 CONTRACTOR: Universal US Construction Inc. Test No. 7 Location: South side of residence pad. 3rd lift Test No. 8 Location: Center of residence nad. 3rd lift Test No. 9 Location: West side of residence pad, 3rd lift Test No. 10 Location: North side of residence Dad. 4th lift Test No. 11 Location: Center of residence pad, 4th lift Description of Material: Tan sand w/rock fragments TEST NO. 7 8 9 10 11 DEPTH 12" 12" 1277 12" 1297 FIELD DENSITY 113.1 113.5 112.6 112.8 113.3 MOISTURE CONTENT % 8.2 7.9 7.6 8.4 8.1 MAX. DENSITY IN THE FIELD % 99.0 99.4 98.6 98.8 99:2 COMPACTION REQUIREMENTS % OF MAXIMUM DENSITY 98% 98% 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 114.2 114.2 11 114.2 1 114.2 114.2 KhMAKKJ: ALL ABOVh -1h; ;'Y RESUL'i'S COMPLY WITH COMPACTION REOUIREMENTS AAD Tested B WD .`�' ,' • y =�R.,. �N q,,,' Respectfully Submitted, Checked By: WN�' '•. Nra. 39584 :y Wissam Naamani, P.E. 'rr — DYNATECH ENGINEERING CORP. STATE OF 4 Florida Reg. No. 39584 ��� A•.� W�` Certificate of Authorization No.: CA 5491 OR10�,. 70 NA r�rrr►ri r r n r r titittit►►�� *A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES ,D E c DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 11.2022 CLIENT: UNIVERSAL US CONSTRUCTION INC. PROJECT: Prol2osed Residence ADDRESS: 1202 NE 93rd Street Miami Shores FL 33138 CONTRACTOR: Universal US Construction Inc. Test No. 12 Location: South side of residence agd 4th lift Test No. Location: Test No. Location: Test No. Location: Test No. Location: Description of Material: Tan sand w/rock fra ments TEST NO. 12 DEPTH 12" FIELD DENSITY 113.4 MOISTURE CONTENT % 7.5 MAX. DENSITY IN THE FIELD % 99.3 COMPACTION REQUIREMENTS 98% % OF MAXIMUM DENSITY 100% MAXIMUM DENSITY (LAB) 114.2 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS AD `����+It s t rI i t rrryr'rf Tested By: WD `.�` p,.• ..••••• .q 'rf,■ Respectfully Submitted, Checked By: WN *-r.�s?: `!G E IVS�;•., �1 * ; No. 39584VZ;;iEsa MaamOni,E. * — DYNATECH ENGINEERING CORP. . p :• STATE OF Florida Reg. No. 39584 �■ *� Certificate of Authorization No.: CA 5491 ti *A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. B3 MATERIAL TESTING ENGINEERING 1676 West 31 PL., Hialeah FL, 33012 Off. 786,773.5871 - FJK. 786,615-5801 CERTIFICATE OF COMPLETED May 9, 2022 Waich 400 S. Dixie Highway, Suite 3 Hallandale Beach, Florida 33009 Subject: Foundation Sail Density and Bearing Capability Certification for Project: Proposed Residence 1202 NE. 93Id Street., Miami Shores, Fl. 33138 GENTLEMEN: in accordance with your request, we have inspected the general site preparation procedures forthe above -named project and soil borings performed by (B3MTE) and density test results performed by Dynatech Engineering Corp, on May 3, 2022, on fill material used to raise the site to grade, Site preparation procedures were in accordance with the geotechnical report prepared by B3 Material Testing Engineering dated May 26, 2021 under project No, 21-0259. Based on our observation, results of borings and density testing., it is our professional opinion that the building pad is suitable for the Construction of proposed structure with foundation proportioned for a design bearing stress of 2500 pounds per square foot without settlement detrimental to the building placed upon it- In my opinion, the settlement will not exceed 0.240 inches y99y5492tz 9; :`� x sinter,a)p Dario A. r ' Fla: ftE�- 77 6 -p;L �W B3 Material nesting En�irlc A4' ! D 1 Y•r<�� � y WWW. a3Engineering. com i ROCHELL ENGINEERING, INC. May 20, 2022 Mr. Ismael Naranjo - Building Official Miami Shores Village Building Dept. 10050 N.E. 2nd Avenue Miami Shores, Florida 33138 Re: 1202 Residence 1202 NE 9311 Street Miami Shores, FL 33138 Permit Number: RC-09-21-2485 Dear Building Official, The present letter is to notify to the concerned parties and corresponding authorities that Julio Torres, as our Field Inspector has performed an inspection of the foundations for this project. The inspection included a visual review of the foundations based on the compaction performed by Dynatech Engineering Corp., dated March 8, 2022 and the Foundations Recommendations specified by B3 Material Testing Engineering on May 26, 2021 under Project No. 21-0259. The topsoil around the proposed foundations was removed to the necessary depth, backfilled with a mixture of sand, limerock and limesand fill in compacted layers of approximately six (6) inches and compacted per AASHTO T-180 to a minimum compaction of 98% of the optimum dry density. We can attest that the Foundation Recommendations set forth on the Geotechnical Report have been followed accordingly and recommend your approval of the foundations and to allow the casting of the Foundations per approved Structural Plans. Should you have any question regarding the above, please do not hesitate to contact our office. ResER RO ����111 1 rllllr • Na. 607350 CC Alexander Rochell, P.E. �';, STATE: OF 1 Florida Professional Engineer �dc�'•, At aRkpp, 2w� Registration No. 60735 ��frs�►ON�� Ir1lt I I 1 10 1500 NW 891'' GOUfI- Suite 212, Doral, FL 33172 Tel: 305.649.4049 B3 MATERIAL TESTING ENGINEERING E s s e n c e o f P e r r e c t i o n 1676 West 31 PL., Hialeah FL, 33012 - Off. 786.773-5871/5889 - Fax. 786.615-5801 May 26, 2021 Project No. 21-0259 SDH Studio FOUNDATION RECOMMENDATIONS: Our recommendations are based on the information provided from the client as to the type of structure planned and on our subsurface investigation performed on the proposed site. Our recommerdations are as follows: 1. Clear entire building area plus 6-0" outside the perimeter of construction am remove all topsoil, and unsuitable subsurface material to the necessary depth. We anticipate an average clearanct- depth of approximately six (6) inches. 2. Compact cleared area to a minimum compaction of 98% of the ❑ptimu:n dry denctty as per AASHTO T-180. Verify densification procedures by taking an adequate of field density compaction tests. The cleared area should be inspected prior to the commencement of the backfilling operation to ensure that all the unsuitable material has been removad. 3. Backfill building area, plus 6-0" outside the perimeter of the structure to the required elevation with a clean mixture of sand, lime rock and lime sand fill (or approved fill material) in compacted layers not to exceed 10 inches of thickness. Compact each layer to a minimum of 98% of the optimum dry density as per AASHTO T180. 4. Excavate footing trenches to the required depth from the ground elevation. Compact the bottom of the footing trench to a minimum compaction of 98% of the optimum dry density as per AASHTO T-180. Verify densification procedures by taking an adequate number of field density compaction tests. Special Considerations: a) The subgrade at the design elevation should be observed by a geotechnical engineer and any topsoil, organic, unsuitable, or deleterious material removed. Proof rolling of the resultant subgrade should be performed to locate objectionable soils that should be removed. During the proof rolling procedure, the stripped soil surface is rolled with the heaviest piece of construction equipment available at the site, such as a heavily loaded tandem axle dump truck having a gross weight of not less than 25 tons. Areas exhibiting deflection or rutting over 1.25 in (32 mm) should be removed and the proof rolling continued until all unsuitable soils have been located and removed or improved in -place. However, the on -site inspector should ensure that the finished subgrade does not exhibit more than 0.5 inch (12.5 mm) of rutting. b) Floor Slab: After the existing building is demolished and the debris carter off -site, all buried structures and utilities should be removed from the planned building area plus 5-foot-wide perimeter. Obtain demolition permit after conducting asbestos surveys before commencement of demolition activities. The cleared site should be graded and filled to required elevation. Fill used to raise the building pad should be granular in texture, have not particle size larger than three inches and have a fines content of no more than 12%. Page416 I B3 MATERIAL TESTING ENGINEERING E s s e n c e o f P e r -f e c. t i o n 1676 West 31 PL., Hialeah FL, 33012 - Off. 786.773-5871/5889 - Fax. 786.615-5801 May 26, 2021 Project No. 21-0259 SDH Studio i. A vapor barrier should be placed over the building pad fill, prior to placement of concrete for the floor slab. This will tend to minimize the entrance of subgrade moisture into the slab. Normally a 10-mil film of polyethylene is used for this purpose. DESIGN RECOMMENDATIONS: The above foundation recommendation having been achieved and verified, we anticipate that the foundation and footings may be appropriately proportioned for a safe soil bearing capacity not to exceed 2,500 psf (pounds per square foot). The use of spread footings and single column oads is suggested. A monolithic slab foundation may also be adopted. LIMITATIONS OF STUDY The exploration and evaluation of the foundation conditions reported herein are considered sufficient in detail and scope to form a reasonable basis for the foundation design. The recommendations submitted for the proposed construction are based on the available subsurface information and the preliminary design details furnished by the client. Any revisions to the plans for the proposed structure from those enumerated in this report should be brought to the attention of the soil engineer, so that he might determine if changes in the foundation recommendations are required. If deviations from the noted subsurface conditions are encountered during construction, they should also be brought to the attention of the soil engineer, so that he can review the changed conditions ad revise these recommendations, if warranted. GENERAL QUALIRCA T1ONS The analysis and recommendations presented in this report are based upon the data obtained from the soil borings performed at the indicated locations and from any other information discussed in this report. This report does not reflect any variations that may occur between borings or across the site. Any statements which appear in this report or on the boring logs regarding odors, color, unusual or suspicious items or conditions are strictly for the information of the client. In addition, the soils samples cannot be relied on to accurately reflect the strata variations that usually exist between sampling locations. The nature and extent of such variations may not become evident until construction. If variations appear evident, it will be necessary to reevaluate the recommendations of the report. In addition, it is recommended that B3 Material Testing Engineering, LLC. be retained to perform construction observation and thereby provide a complete professional geotechnical engineering service through the observational method. For environmental due to diligence, a phase I and/or phase II Environmental Site Assessments is recommended. Page 5 16 B3 MATERIAL TESTING ENGINEERING E s s e n c e o f P e r f e c t i o n 1676 West 31 PL., Hialeah FL, 33012 -Off. 786.773-5871- Fax. 786.615-5801 CERTIFICATE OF COMPLETED FILL May 9, 2022 Waich 400 S. Dixie Highway, Suite 3 Hallandale Beach, Florida 33009 Subject: Foundation Soil Density and Bearing Capability Certification for Project: Proposed Residence 1202 NE. 93'd Street., Miami Shores, FI. 33138 GENTLEMEN: In accordance with your request, we have inspected the general site preparation procedures for the above -named project and soil borings performed by (B3MTE) and density test results performed by Dynatech Engineering Corp, on May 3, 2022, on fill material used to raise the site to grade. Site preparation procedures were in accordance with the geotechnical report prepared by B3 Material Testing Engineering dated May 26, 2021 under project No, 21-0259. Based on our observation, results of borings and density testing., it is our professional opinion that the building pad is suitable for the construction of proposed structure with foundation proportioned for a design bearing stress of 2500 pounds per square foot without settlement detrimental to the building placed upon it. In my opinion, the settlement will not exceed 0.240 inches % , I //! 14 Sincere Dario A. r " Fla: Reg. ME* OF W .: B3 M I esting En iin, �g. �' �'� .fib p � �9 . • F�. DHlbm;sdf+sw4 W W W.83Engineering.com '"£OTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRELUNG SERVICES -DEd DYNATECH ENGINEERING CORP. W W W.DYNATECHENGINEERING. COM MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: March 8, 2022 CLIENT: UNIVERSAL US CONSTRUCTION INC. PROJECT: Proposed Residence? ADDRESS: 1202 NE 93rd Sireet. Miami Shores. FL 33138 CONTRACTOR: Universal US Construction. Inc. MATERIAL DESCRIPTION: Tan sand whock fragments SAMPLED BY: JA TESTED BY: JA TEST RESULTS Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE 3.9 6.1 8.6 11.7 DRY DENSITY Optimum Moisture 114.2 Percent 100%Maximum Dry Density 9.9 lbs./cu.R. % Passing 3/4" Sieve 74.3 Perccr�l Sampled By: WD Tested By: WD 108.1 111.8 113.7 112.8 116 114 112 110 108 106 Checked By: WN ►►►►►,ttIIII ►r1111 4 6 8 10 12 14 5Q.••••jC•E NS'• '� '� Respectively submitted, As a mutual protection to clients, the public and ourselves. all reports �` �� �, f •'•. �� are submiticd as the confidential property of clients, and authorization for use, publication of slatcrnents. conclusions or extracts from or regardinor : No• 39584 * i Wissam Na mani, P.E. our reports is reserved pcndke our written approval. — 9r=DYNATECH ENGINEERING CORP. :�Florida Reg. No. .p STATE OF Certificate of Authorization No.: CA 5491 ?� •. '•,,�,�: • �� Q R ID Ilk 11r1rr+t l t 11 t1t►►►�► D R Y D E N S I T Y ,EOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTINO I ASBESTOS I ROOP TESTING I INSPECTION SERVICES I DRILLING SERVICES JrD Ec DYNATECH ENGINEERING CORP. W WIV.DYNATECHENGINEBRINO.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 8, 2022 CLIENT: UNIVERSAL US CONSTRUCTION INC. PROJECT: Pro used Residence ADDRESS: 1202 NE 93rd Street. Miami Shores. FL 33138 CONTRACTOR: Universal US Construction Inc. Test No. I Location: East side of residence pad, 1" lift Test No. 2 Location: Center of residence pad, lit lift Test No. 3 Location: West side of residence pad. lit lift _ Test No. 4 Location: North side of residence pad, 2"d lift Test No. 5 Location: Center of residence ad 2"d lift Description of Material: Tan sand wlrock fraements TEST NO. 1 2 3 4 5 DEPTH 12" 12" 12" 12" 12" FIELD DENSITY 112.9 1 112.5 112.7 113.0 112.4 MOISTURE CONTENT % 8.6 9.0 8.8 8.4 8.8 MAX. DENSITY IN THE FIELD % 98.9 98.5 98.7 98.9 98.4 COMPACTION REQUIREMENTS OF MAXIMUM DENSITY 98% 98% 98% 1 98% 98% 100% MAXIMUM DENSITY (LAB) 114.2 1 114.2 1 114.2 114.2 1 114.2 REMARKS: ALL ABOVE TEST -RESULTS COMPLY WITH COMPACTION REQUIREMENTS ����sts s t r u t rrrrrr'�I SAAD Tested By: WD ��.�`�Q•• •••• E Respectfully Submitted, �•'•.; 9 Checked By: WN :���•r • ��� �f y * , No. 39584 * -- • - Wissa aamanr, P.E. * = DYNATECH ENGINEERING CORP. .,p•: STATE OF Florida Reg. No. 39584 �,'P '• ' ��: Certificate of Authorization No.: CA 5491 %f�.: • F� a R 1� •'Grp' r�r'►rurrnnts�N��'� "A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual prmc�;ion to the clients, the public and ourselves, all reports arc submitted as the confidential property of clients, and authorization for publication of statement conclu%ins or extracts from or regarding our reports is reserved pending on our written approval. .OTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING 1 INSPECTION SERVICES I DRILLING SERVICES €c DYNATECH ENGINEERING CORP. W W W.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 8.2022 CLIENT: UNIVERSAL US CONSTRUCTION, INC. PROJECT: Proposed Residence n ADDRESS: 1202 NE 93" Street Miami Shores. FL 33138 CONTRACTOR: Universal US Construction. Inc. Test No. 6 Location: Soil side of residence pad. 2"d lift Test No. Location: Test No. Location: Test No. Location: Test No. Location: Description of Material: Tan sand whock fra ments TEST NO. 6 DEPTH 12" FIELD DENSITY 112.7 MOISTURE CONTENT % 8.7 MAX. DENSITY IN THE FIELD % 98.7 COMPACTION REQUIREMENTS % OF MAXIMUM DENSITY 98% 100% MAXIMUM DENSITY (LAB) 1 114.2 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION RL• UIREMENTS ���tttttttt+r►er►1► Tested By: WD ,``�•`P�,.SAAfl•h'4rrrr,�fA ti Respectfully $ubmitted, Checked By: WN -fit?; `IC E ✓Ifse •:,� •.� ' No. 39584 - - Wissam Naarnani, P.E. * = DYNATECN ENGINEERING CORP. 0% STATE OF '4tr S Florida Reg, No. 39584 C2'•.•,.�. •�� Certificate of Authorization No.: CA 5491 00 ►ss70hfALj�•�'`� ►►►r►rrtItlltttWt 0 •A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports arc submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. ,QTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES �oEc DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 8.2022 CLIENT: UNIVERSAL US CONSTRUCTION. INC. PROJECT: Proposed Residence ng ADDRESS: 1202 NE 93rd Street. Miami Shores, FL 33138 CONTRACTOR: Universal US Construction, Inc. Test No. 7 Location: South side of residence pad, 3rd lift Test No. 8 Location: _ Center of residence pad. 3rd lift Test No. 9 Location: ^ West side of residence pad. 3rd lift _ Test No. 10 Location: North side of residence pad. 41h lift Test No. 11 Location: Center of residence pad, 4th lift Description of Material: Tan sand w/rock fragments TEST NO. 7 8 9 10 11 DEPTH 12" 12" 12" 12" 12" FIELD DENSITY 113.1 113.5 112.6 1 112.8 113.3 MOISTURE CONTENT % 8.2 7.9 7.6 8.4 8.1 MAX. DENSITY IN THE FIELD % 99.0 99.4 98.6 98.8 99.2 COMPACTION REQUIREMENTS % OF MAXIMUM DENSITY 98% 98% 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 1 114.2 1 114.2 114.2 1 114.2 1 114.2 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS ,,,,ttun+rrrr►► t,> X* SAAD �►�.,, Tested By: WD .�`��..,. �� E Ns. .q�,Respectfully Submitted, Checked By: WN .����: �- * ; No. 39584 * _ - Wissarn Naarnani. P.E. * = DYNATECH ENGINEERING CORP. STATE OF Florida Reg. No. 39584 ���/ f,•,: ' ��� Certificate of Authorization No.: CA 5491 to •rffi C s ... S NitYlONA ON, •A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring lest must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports arc submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval „gpTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES Ec DYNATECH ENGINEERING CORP. V WW.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: March 11, 2022 CLIENT: UNIVERSAL US CONSTRUCTION, INC. PROJECT: Proposed Residence r@ _ ADDRESS: 1202 NE 93rd Street. Miami Shores FL 33138 CONTRACTOR: Universal US Construction Inc. _ Test No. 12 Location: South side of residence pad. 4 h lift Test No. Location: Test No. Location: Test No. Location: Test No. Location: Description of Material: Tan sand w/rock fragments TEST NO. 12 DEPTH 12” FIELD DENSITY 113.4 MOISTURE CONTENT % 7.5 MAX. DENSITY IN THE FIELD % 99.3 COMPACTION REQUIREMENTS OF MAXIMUM DENSITY ` 98% 100% MAXIMUM DENSITY (LAB) 1 114.2 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS ,���►tltfIII fill►►►/ 'CipAa ,••�� Res ectfull Submitted, Tested By: WD .��` Q� � �`�� Respectfully Checked By: WN �.•` tamNS�:•.,,�'.� Nv. 39584 1� Wissat Naamani. P.E. * = DYNATECH ENGINEERING CORP. STATE OF Florida Reg. No. 39584 �� F A•;` Certificate of Authorization No.: CA 5491 ►,s10NA1.�► �►1tPIilTittt��� •A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination a soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES DYNATECH ENGINEERING CORP. W W W.DYNATE CHENGINEERING.COM Miami, May 3, 2022 Mr. Ricardo Elias UNIVERSAL US CONSTRUCTION, INC. 9330 SW 1681h Street Palmetto Bay, FL 33157 Re: Proposed Residence @ 1202 NE 931d Street Miami Shores, FL-1-3138 Dear Mr. Elias: Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on May 3, 2022 at the above referenced project. DEC was authorized to perform a compaction test only. The purpose of our test was to determine the degree of compaction of the tested layer of material only. In no way shall a compaction test replace a demucking inspection, soil bearing capacity determination, or a pad certification. A soil boring test must be performed by client if not yet done, prior to construction to verify subsoil conditions. Underlying soils below test levels must be verified to prevent future settlements. (DEC) was not authorized to perform supervision and certification of the building pad preparation. This is not a pad certification. Our reports must be provided to all involved parties for their approval. Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on other areas or dates. Any subsequent site disturbances due to water erosion, rain, storm gutters discharging at footings, construction activities, excavations, overgrown, vegetation, traffic and other disturbances will void this test and the site must be re - compacted and re -tested prior to construction. Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils is required, we can provide a proposal for performing an environmental analysis of the soil materials. No other analysis is implied or warranted. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Enclosed find copies of the compaction test results. It has been a pleasure working with you and look forward to do so in the near future. Sincerely yours, til �1 Wissam aamani, P. E. DYNATECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 Certificate of Authorization No.: CA 5491 ���IIIIIII!!lr++� �.�`,`+��► 5AA D N�gr`,�r� k ; No. 39584 .fl STATE OF r oc�- ''•tea-' Q Rtda�'{`.'= G F 111+li111111+�',1 ` 1 GEOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES �DEc DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM MOISTURE -DENSITY RELATIONS OF SOILS PROCTOR COMPACTION TEST DATE: May 3.2022 CLIENT: UNIVERSAL US CONSTRUCTION INC. PROJECT: Proposed Residence @. ADDRESS: 1202 NE 93rd Street. Miami Shores. FL 33138 CONTRACTOR: Universal US Construction, Inc. MATERIAL DESCRIPTION: Tan sand SAMPLED BY: WD TESTED BY: WD TEST RESULTS Sample Number 1 The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop ASTM D-1557. % MOISTURE 4.9 6.3 7.9 12.0 DRY DENSITY Optimum Moisture 9.2 Percent 100% Maximum Dry Density 1 QL lbs./cu.ft. % Passing 1/4" Sieve 96 Percent Sampled By: WD Tested By: WD 1020.2 103.8 105.2 104.4 108 106 104 102 100 98 Checked By: WN A`AQ►rr► 4 6 8 10 12 14 N Res ectivel submitted ��� ��••'•1 Ci•E 1NS'' �/ �'. P Y , As a mutual protection to clients, the public and ourselves, all reports ' • �' £�•'•.'� are submitted as the confidential property of clients, and authorization =• No. 39584 for use, publication of statements, conclusions or extracts from or rcgard'mg* W issarn Naam , our reports is reserved pending our written approval. — * S)YNATECH NGINEERING CORP_ .� SfATE OF ;�Tlorida Reg. No. 39584 • 4► Certificate of Authorization No.: CA 5491 ol el OR D R Y D E N S I T Y 2 GLOTECHNICAL I ENVIRONMENTAL I MATERIALS TESTING I ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES j,',jrE'6 DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM FIELD DENSITY TEST OF COMPACTED SOILS DATE: Mqy 3 2022 CLIENT: UNIVERSAL US CONSTRUCTION, INC. PROJECT: Proposed Residence 1�7a, ADDRESS: 1202 NE 93rd Street. Miami Shores, FL 33138 CONTRACTOR: Universal US Construction, Inc. Test No. 1 Location: East side of residence underslab Test No. 2 Location: West side of residence underslab Test No. 3 Location: Center of residence underslab Test No. 4 Location: North side of residence underslab Test No..5 Location: South side of residence underslab Description of Material: Tan sand TEST NO. 1 2 3 4 5 DEPTH 12" 12" 12" 12" 12" FIELD DENSITY 105.2 105.6 104.9 105.8 105.1 MOISTURE CONTENT % 7.0 7.4 6.8 7.7 7.1 MAX. DENSITY IN THE FIELD % 98.5 98.9 98.2 99.1 98.4 COMPACTION REQUIREMENTS % OF MAXIMUM 98% 98% 98% 98% 98% 100% MAXIMUM DENSITY (LAB) 106.8 106.8 106.8 106.8 106.8 REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS * Please note this is not a pad certification. A soil boring must be performed to determine subsoil conditions below the tested compaction layer prior to construction. '`,►��i11111l111111f, 5AA D N,�q•,,,f, Respectfully submitted, Tested By: WD Checked By: WN ' * •. No. 39584 fDYNATECH ENGINEERING CORP. .0 STATE OF .'�� Florida Reg. No. 39584 �p^;. f� 0 1D Certificate of Authorization No.: CA 5491 . \ NA 1j"IfI111a/m►►�� *A density test determines the degree of compaction of the tested layer of material only. In no way shall a density test replace a soil bearing capacity determination. A soil boring test must be provided by client, prior to construction to verify subsoil conditions. As a mutual protection to the clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statement conclusions or extracts from or regarding our reports is reserved pending on our written approval. 3 21 P - Awpa i e- I - i Z 7 2:7 ---1 Z �- '�� z �//2 / ; a 9 0 r J 3256 W Hillsboro Blvd. Deerfield Beach, FL 33442 Phone: (954) 549-5509 m)ww.pestdepot• coy? Date of Treatment(s): May 4, 2022 1202 NE 93rd Street, Miami Shores, FL 33138 This structure has received a treatment for the prevention of subterranean termites. This treatment is in accordance with the rules and regulations established by the Florida Department of Agriculture, Consumer Services and Broward County Codes. If you have any questions or concerns please feel free to contact us at the number above. EM 3256 W Hillsboro Blvd, Deerfield Beach, FL 33442 Phone: 954-549-5509 Certified Environmental Inspectors and Remediation Specialists Balancing Life in the Soil, the Foundation of Life "Intellligent Termite Control" TERMITE CONTROL A NOTICE OF THIS TREATMENT HAS BEEN AFFIXED TO THE FUSE SERVICE AGREEMENT BOX OR HOT WATER TANK UNLESS OTHERWISE INDICATED I� Residential i,.... Commercial PURCHASER NAME STREET ADDRESS CITY STATE ZIP CODE 786,715.1873 SERVICE PHONE METHOD OF PAYMENT Payment upon completion fir Terms -Stated Below At Closing -Title Co T "title Co -Add F 50% Deposit Terms TO BE PAID IN FULL PRIOR TO TREATMENT PESTDEPOT.COM IS HEREBY AUTHORIZED TO TREAT THE PREMISES DESCRIBED ABOVE FOR THE CONTROL OF: Dryw ood Termites eControl of • Subterranean Termites (' Presumptive Evidence Of I• other Soil Pretreat f1� Prevention of Fumigation -" Clean Heat Localize Treatment SERVICE AGREEMENTS: Lifetime Retreatment Renewable Service Agreement 5 Year Renewable Service Agreement No Guarantee Issued 1 Year Guarantee Limited Damage Guarantee Additional $ PESTDEPOT.COM will retreat the structure(s) for covered Termites at no cost to the Customer should an infestation be found. Buyer agrees to pay a late charge the greater of $25.00 or 10% of the amount of any installment which is not paid within 10 days of date due, In case of default in the payment of any installment for more than 30 days. PESTDEPOT.COM, or its assignee, may elect to declare the entire balance to be immediately due and payable together with all costs of collections, Including reasonable attorney's fees. CONTINUOUS PROTECTION AGREEMENT Annual Renewal payment is currently: $ plus lax where applicable PESTOEPOT COM reserves the right to change the renewal amount a' any time without prior notice or terminate this agreement if terms and conditions are not coirnPhe[ will, A transfer fee of $35 will be charged to transfer this agreement Change in Law: In IM evenl of a change In applicable Federal Slate., or Local Law. material In the manner in whitll I'CSTDI'POI COM delivers its services or discharges its obligations under this agreement R I•SIOFPOT COM reserves the right to increase the Annual Renewal Fee wghcut the .[ry7uvt :-u-tionud Iimitalion or terminate this agreement, Date of Treatment Wed 05/04/22 9:00 LIMITED RE -TREATMENT ONLY GUARANTEE NAME 1202 NE 93rd Street STREET ADDRESS Miami Shores FL 33138 CITY STATE ZIP Soil Pretreat 2028 Sq Ft Outside _ TYPE NUMBER STRUCTURES DEV: GRID LOC: 1. Initial Treatment - Soil Pretreat $800.00 2. Other Service 3. Tax 4. Total Price $800,00 5. Less Cash Down payment 6. Unpaid Balance Due $800.00 (to be paid as slated below) 1. THIS CONTRACT CONTAINS EXCLUSIONS, LIMITATIONS AND DISCLAIMERS LISTED ON THE REVERSE SIDE 2. YOU THE BUYER MAY CANCEL THIS TRANSACTION ANY PRIOR TO MIDNIGHT OF THE THIRD (3RD) BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION 3. YOU ARE ENTITLED TO AN EXACT EXECUTED COPY OF THIS AGREEMENT 4. ALL OR PART OF THIS WORK MAY BE SUBCONTRACTED A CERTIFIED AND LICENSED COMPANY Accepted by (Print) BUYER OR BUY R'5 AUrtlOytl7FO AGF T SiGNATURf r YE?Srpf:PL 31 CID • IN CT4f7 'Notice of IcWstm it as been affixed Comments: 954-549-5509 www.pestdepoLcom ' www.wholesaletermite.com www.wholesalefurnigation.corn ' www.wholesalemold.corn ' www.wholesalerodents.com GENERAL TERMS AND CONDITIONS By specific, reference hereto. the Purchaser understands that General Terms and Conditions are hereby made a part of the Service Order and apply without exception. Purchaser further understands that their signature on this Agreement accepts the terms offered by PESTDEPOT.COM, hereby referred to as "The Company," for good and valuable consideration receipt of which is hereby acknowledged. 1. If moisture and/or structural conditions which are conducive (o Termites are subsequently found to exist without ground contact, then The Company shall be relieved of any and all liability. 2. Structural or mechanical defects which result in water leakage in interior areas or through the roof or exterior walls of the premises may destroy the effectiveness of The Company's treatment, thereby permitting infestation to continue after the dale of Initial treatment. If such a condition is discovered, it Is agreed that the customer will be responsible for making such repairs as are necessary to correct the structural or mechanical defect(s) immediately upon discovery of such defect. Should a re -treatment of any affected area(s) be needed, the expense of such will be charged to the customer as a condition of a continuation of the warranty, or warranty may be terminated unless full re -treatment is purchased by purchaser. 3, The Company's liability shall be terminated should 'fhe Company be prevented from fulfilling its responsibilities under the terms of this Service Order of the Guaranty by reason of Acts of War, whether declared or undeclared, Acts of any duly constituted Government Authority, strikes, or Acts of God. 4, This Agreement covers the premises diagramed on (he Graph and Specifications Sheet as of the dale of actual treatment, and in the event the premises are structurally modified, altered, or otherwise changed after the date of initial treatment, this Agreemen( shall terminate unless a prior written agreement shall have been entered Into by the Purchase for The Company unless alteration or changes in writing and executed by a corporate officer of The Company under the corporate seal. 5. It is understood and agreed between the parties that this Contract, the Graph and Specifications Sheets which bear this Contract Number, and, upon issuance, the Guaranty constitute the complete agreement between parties and that said agreement may not be changed or altered in any manner, oral or otherwise, by any representative of The Company unless alteration of change be in writing and executed by a corporate officer of The Company under the corporate seal. 6. This Agreement is a limited control guarantee, which is limited to local lrealment only and does nol cover re-lurnigation after the initial one yearguarentee. The Company shall not be liable for any consequential damage as a result of treatment to the subject properly. Re -inspection will be done it requested or will be done annually at the lime of renewal %.. It is understood and agreed between (he parties that should it be necessary for The Company to institute legal proceedings to recover damages from the Purchaser for the breach of this Agreement or for non-payment under its terms the Purchaser shall be responsible for and shall pay all of The Company's attorney's fees, court costs, pre and post tudament interest. and anv and all collection fees, 8. Payment shall be made within thirty (30) days from the date of services rendered Any account with an unpaid balance at the end of said term will be charged interest on the unpaid portion of the rate of 1.5% (one and one half percent) interest per month until such time the account has been paid in full. 9- It is understood and agreed between the parties that the Purchaser's signature on this agreement acknowledges notice of hen on the structure(s)which form the subject matter of (his agreement, In the event that legal or collection measures are necessary to enforce the terms of this agreement. 10. The Company's liability under this contract shall terminate when access to the premises for the purpose of carrying out the terms and conditions of the contract is refused by the Purchaser or its agent, 11. The Company will exercise reasonable care in its treatment procedures but will not accept responsibility for broken roof tiles, gutter, solar healer, landscape foliage, puncture and subsequent leakage of undetectable buried or hidden water pipes, electrical conduits, TV cables. and A/C or Healing ducts or plumbing, or any other inadvertent damage occasioned by properly performed procedures. 12. Notwithstanding that the serviced property is the subject of real estate transfer, refinance, etc., payment for services rendered shall be made within the staled time. 13, This agreement shall be governed by the laws of the Stale of Florida and venue with respect to any legal action to enforce, interpret, or otherwise deal with any provision hereof shall be maintained exclusively in Broward and Palm Beach Counties, Florida. 14, All or part of this work may be contracted to a Certified and Licensed Company. 15, Postponement or job must be received by 9:00 AM of the prior day prior to the date of (he scheduled job Fee for postponement wlthoul required no(ce: 20% of fumigation lee 16. SUBTERRANEAN TERMITE WARRANTY DOES NOT INCLUDE FORMOSAN TERMITE TREATMENT (COPTOTERMES FORMOSANUS) UNLESS SPECIFICALLY NOTED ON THE FRONT OF THIS CONTRACT. SUBTERRANEAN TERMITE LIMITED CONTROL. GUARANTEE SUBJECT TO THE GENERAL TERMS AND CONDITIONS, 'THE COMPANY WILL ISSUE A LIMITED CONTROL GUARANTEE AND. AT NO EXTRA COST APPLY ANY NECI:'SSARY ADDITIONAL_ TREATMENT TO THE: PRE.MISF..S IF RF-INFFS'fAfION IS FOUND THEREIN DURING THE PERIOD OF THE GUARANIEE THE PURCHASER FURTHER UNDERSTANDS THATTHE COMPANY'S LIABILITY UNDER'THIS AGREEMENT IS LIMITED TO RETREATEMNT ONLY AND IS IN NO WAY IMPLIED OR OTHERWISE IS RESPONSIBLE FOR DAMAGES OR REPAIRS TO THE STRUCTURE OR CONTENTS. DRYWOOD TERMITE, POWDER POST BEETLE AND WOOD BORER LIMITED GUARANTEE SUBJECT TO THE TERMS AND CONDITIONS THE COMPANY WILL RETREAT THE STRUCTURE FOR THE CONTROL OF DRYWOOD TERMITES OR POWDER POST BEETLES AND WOOD BORERS, AND WILL ISSUE A LIMITED CONTROL GUARANTEE WHICH WILL PROVIDE FOR RETREATMENT AT NO EXTRA COST, SHOULD A RE -INFESTATION BE DISCOVERED DURING THE PERIOD THE GUARANTEE IS IN FORCE. COMPANY'S LIABILITY UNDER THIS AGREEMENT IS LIMITED TO RETREATMENT ONLY AND IN NO WAY. IMPLIED OR OTHERWISE, IS RESPONSIBLE FOR DAMAGES OR REPAIRS TO THE STRUCTURE OR CONTENTS. Florida Department of Agriculture and Consumer Services --r� Division of Agricultural Environmental Services CONSUMER NOTICE FORM NICOLE "NIKKI" FRIED Rule 5E-14.105, F.A C. COMMISSIONER A pest control company must give you a written contract prior to any treatment of each wood -destroying organism. It is very important that you read and understand the contract you are signing. The pest control company is only obligated to follow the terms of the contract you have signed, regardless of other statements by the company or salesperson. (Note: Contracts for treatment for new construction can be issued to the builder and provided to you at closing). BASIC REQUIREMENTS F,QR CQNTRACTS • The contract must state the common name of the wood -destroying organism to be controlled by the company (e.g. subterranean termite, powder post beetle). If the contract is for termite control, the contract must clearly state whether Formosan termites are covered or not. • Some contracts do not include a treatment at the time the contract is issued, and that should be clearly stated. If a treatment is performed as part of the contract, the cost for the treatment must be stated. If the treatment is only for certain areas. the contract should clearly state that it is for "spot treatment" only. • The contract must state if it is a retreatment only or a retreatment and repair contract. If it is a retreatment and repair contract, carefully read the sections of the contract that state when repairs will or will not be covered by the contract. REQUIREMENTS FOR STATING WHEN TREATMENT OR REPAIR WILL NOT BE COVERED BY THE CONTRACT • Repair contracts will not cover repairs from termite damage under every condition. The contract must state when retreatment or repair will be done, and conditions under which the company can refuse to retreat or repair, • These conditions have to be stated and be under headings in the contract that are in bold print. Companies typically refuse repair or retreatment if the condition of the house is such that moisture or leaks result in termite infestation, or where siding makes it hard to see termite infestation Examples of this are: • Cracks in concrete slabs • Wood or wall siding in contact with ground • Plumbing leaks • Leaks in the roof • Water accumulating against side of house The law does require that companies notify you if they see conditions which would void the repair promise and they have to give you a chance to correct the condition before voiding the contract or denying repair coverage. • Contracts may have a condition that does not cover Formosan termite damage until a specific time period has passed. This means that if damage occurs during this period the company will not pay for repair. ■ You have the right to compare contracts from other companies before signing a contract with a company. Choose the company that gives you the best contract options. ■ If you have any questions about the terms of the contract, cr concerns about the compliance history of the company with regard to pest control laws or regulations, contact the Department of Agriculture and Consumer Services at phone number: 850-617-7996 or email: biircomplaints@fdacs.gov. I understand that I am enteringinto a contract with PESTDEPOT.COM (fill in company name) to provide wood -destroying organism(s) treatment, and I have read and understood the terms of the contract. Print Name of Consumer Signature of Consumer Print Name of P 9t ConlrbAlepresentative Signature of Pest Cont Vprer ati FDACS-13692 Rev 07/21 Dat Title: Property Owner orr authorized agent Company, PESTDEPOT. COM Page 1 of 2 (La traduccibn espa)ola en la espalda) Bureau of Inspection and Incident Response, 850-617-7996 New Construction Subterranean Termite OMB Approval No.2502-0525 Service Record (exp.05/30/2018: This form is completed by the licensed Pest Control Compan Public re.portIng burden for this collection of information is estimal[i} Ur average 15 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. This Information tis required to obtain benefits. HUD may not collect this information, and you are not required to complete this form, unless it displays a currently valid OMB control number, Section 24 CFR 200,926d(b)(3) requires that the sites for HUD insured structures must be free of termite hazards. This information collection requires the 6UiIdef 10 certify that an authorized Pest Control company performed all required treatment for termites, and that the builder guarantees the treated area against Infestation for one year. Builders. pest control companies, mortgage lenders, homebuyers, and HUD as a record of treatment for specific homes will Use the information collected. The information is not considered confidential, therefore, no assurance of confidentiality is provided. 'This report is submitted for informational purposes to the builder on proposed (new) construction cases when treatment for prevention of subterranean termite infestation is specified by the builder, architect, or required by the: lender, architect, FHA, or VA. All contracts for services are between the Pest Control company and builder, unless stated otherwise. Section 1: General Information (Pest Control Company Information) Company Name: Pestdepot.corn Company Address 3256 W Hillsboro Blvd Company Business License No, JB:312274 FHA/VA Case No. (if any) Section 2: Builder Information T Company Name Section 3: Property Information City Deerfield Beach State FL Company Phone No. 954-549-5509 Phone No. 786.715.1873 Zip 33442 Location of Structures Treated Street Address or Legal Description, City,State and Zip) 1202 NE 93rd Street, Miami Shores, FL 33138 Section 4: Service Information Date(s) of Service(s) 05/04/22 Type of Construction (More than one box may be checked) Fx I Slab Basennont l ] Crawl U Other Check all that apply: [,� A. Soil Applied Liquid Termiticide Brand Name of Termiticide: Premise EPA Registration No. 432-1331 Approx. Dilution (%): 0.05 Approx. Total Gallons Mix Applied: 203 - - Treatment completed on exterior: [x_� Yes [ No B Wood Applied Liquid Termiticide Brand Name of -Termiticide' _ _ _ EPA Registration No.. Approx Dilution (%): Approx. Total Gallons Mix Applied; C. Bail system Installed Name of System D. Physical Barrier System Installed Name of System EPA Registration No.- Number of Stations installed Attach installation information (required) Service Agreement Available? ✓ Yes No Note' Some state laws require service agreements to be issued. This form does not preempt state law. Attachments (List) Contract Comments 2028 SQ FT Outside Name of Applicator(s) StanleyJacobs - _ y Certification No. (if required by State law) JE„1 21307 The applicator has used a product in accordance with the product label and state requirements All materials and methods used comply with state and federal regulations. Authorized Signature t� Date 05/04/22 Warning: HUD will prosecute false claims an slaiamenis. Conviction may result in criminal and/or civil penalties. (18 U.S.C. 1001, 1010. 1012; 31 U S C. 3729, 3802) form HUD-NPMA-99-B (0812008)