WS-10-21-2738 FRAMINGROBERTO CARLOS TOTH P.E.
1279 SW 23 ST
APT A
Miami, F133145
(786)753-2240
info@jpconsultantinc.com
To: Building Official,
Miami Shores Village Building Division
10050 NE 2nd Ave
Miami Shores, FI 33138
From: Roberto C. Toth, P.E.
FL Reg. No. 77032
Date: January 17th, 2022
RE: Permit # WS-10-21-2738
Impact Windows and Doors Inspection.
Dear Sir:
Address: 1251 NE 94 Street
Miami Shores, A 33138
The inspection consisted of verifying the structural/framing installation was in compliance with
Notice of Acceptance's NOA's. Product Control Approval Specifications drawings details submitted with
Permit application, and the Florida Building Code: FL35387.1 (Alum Casement), FL17595.1
(Alum Horizontal Roller), FL29477.1 (Alum French Door), FL17596.1 (Alum Sliding Glass Door).
Due to the field conditions connection was made with Framing P.T. wood Bucks using 1"x4" for
Horizontal Roller and Casement Windows were anchored with 1/4" tap -con or wood -screw @ 6" with
1-1/4" penetration into wood.
Framing P.T. Wood Bucks using 2"x4" for French Doors and Sliding Glass Door were anchored with
1/4" tap -con or wood -screw @ 6" with 1-1/2" penetration into wood.
All windows frames were properly sealed with Heavy Duty caulking outside and inside. Silicon was
applied to tap -con anchors at window's sill frames to prevent water penetration.
Based on the visual inspection performed and to the best of my knowledge and professional judgment, I
certify that: The Windows, and Doors can support the design conditions and were installed as per
approved plans and documents.
As a routine matter and in order to avoid possible misunderstanding, nothing in this
certification should be construed directly or indirectly as a guarantee of any portion of the
structure. This certification represents an accurate appraisal of the present condition of the portion of
the existing building inspected, based upon careful evaluation of observed conditions and to the
extent reasonably possible. There was no destructive testing done at the building and none of the
covered structural members could be visually inspected. Therefore, your consideration for final
approval and closing the subject permit is requested.
If you have any additional questions or comments, please do not hesitate to contact me at: (786) 753-2240.
Sincerely, ��' �0 C. Rt
o��... �kGE�SI�
` * ❑ 7032 *�
STATE OFj
Roberto Carlos
FL. Reg. No. 770 ,, SON L E��.