RF-08-21-2035 FIELD DENSITYEngineering for Build, LLC. CA 30228
May 24th, 2022
Miami Shares Village
Building Department
Location of Project: 730 RESIDENCE ADDITION
730 NE 101ST ST.,
MIAMI SHORES, FLORIDA 33138
Master Permit # : RC-08-21-2035
Folio Number: 11-3206-017-2200
Ref: Sail Statement of allowable bearing capacity
I, Andres Feliciano, as an Engineer of Record of the project in reference, have
realized a Visual Inspection for the allowable bearing capacity of the soil foundation
of the above project and based on the Field Density Test Report (") dated May 201h
2022 done by NELCO, Testing & Engineering Services, Inc. and signed and sealed
by Vinayagar M. Balakrishnan V, P.E. #63107 we found that:
"well compacted sand/gravel grade as per field density test result (attached) with a
compaction greater than 95% a minimum soil bearing capacity of 2.500 psf'. To the
best of my knowledge and belief, the above -described statement complies with
Florida Building Code 2020. 71n ed.
In case that you have any question please don't hesitate to contact me.
Cordially yours; r
NELIC�,gN
•SE O
L'2A•/2
AFM,Feliciano,
r 5
FL Reg. P.E # 75404 �e•" `,
Engineering for Build, LLC.SIC3�1P
CA #30228
Sign & Seal Field Density Test Report attached.
(c) Statement that the documents are believed to be correct to the best of the
engineer's knowledge, and that the accuracy of the information cannot guaranteed,
i:. hiI :hi! _ = 'Uf=fJS L'�f?. 51E'fl_ • f ilAH1, FL. ?,1E0
m
tyrf
2�71 Er
TESTING 6 ENGINEERING SERVICES, INC.
FIELD DENSITY TEST REPORT
Client: Lazaro Morales Date: May 20, 2022
1001 SW 38t' Terrace Job: D - 2205255
Miami, F133165
Project Name: Residence — Addition _ f
Project Location: 730 NE 101st Street., Miami Shores, Fl
_ _PROCTOR DATA
Proctor Max. Dry Optimum
No. Soil Description Densi ct) Moisture _(%)
113456 _ Brown Sand with Gravel 112.7 10.1 I.
Required Com action (%) 95% Test Depth Penetration inches): 12"
FIF,I,D DENSITY TEST RESULTS
Test
No.
Proc.
No.
Test Location
Lift
No.
Dry
Density
%
Moist.
%
I Com
Result
1
113456
Northeast Area on Column Pad
Footing
107.8
9.3
95.7
Pass
2
113456
Southeast Area on Column Pad
Footing
108.0
9.1
95.9
Pass
3
113456
Southwest Area on Column Pad
Footing
107.7
9.7
„ 95.6
PuJJ
j
::=EE
I I
Comments:
13370 SW 131s' Street, Suite 105, Miami, FL. 33186 (305) 259-9779
www.nelcotestinz com Iielco 1 -,.nelcotesting.com