Loading...
RF-08-21-2035 FIELD DENSITYEngineering for Build, LLC. CA 30228 May 24th, 2022 Miami Shares Village Building Department Location of Project: 730 RESIDENCE ADDITION 730 NE 101ST ST., MIAMI SHORES, FLORIDA 33138 Master Permit # : RC-08-21-2035 Folio Number: 11-3206-017-2200 Ref: Sail Statement of allowable bearing capacity I, Andres Feliciano, as an Engineer of Record of the project in reference, have realized a Visual Inspection for the allowable bearing capacity of the soil foundation of the above project and based on the Field Density Test Report (") dated May 201h 2022 done by NELCO, Testing & Engineering Services, Inc. and signed and sealed by Vinayagar M. Balakrishnan V, P.E. #63107 we found that: "well compacted sand/gravel grade as per field density test result (attached) with a compaction greater than 95% a minimum soil bearing capacity of 2.500 psf'. To the best of my knowledge and belief, the above -described statement complies with Florida Building Code 2020. 71n ed. In case that you have any question please don't hesitate to contact me. Cordially yours; r NELIC�,gN •SE O L'2A•/2 AFM,Feliciano, r 5 FL Reg. P.E # 75404 �e•" `, Engineering for Build, LLC.SIC3�1P CA #30228 Sign & Seal Field Density Test Report attached. (c) Statement that the documents are believed to be correct to the best of the engineer's knowledge, and that the accuracy of the information cannot guaranteed, i:. hiI :hi! _ = 'Uf=fJS L'�f?. 51E'fl_ • f ilAH1, FL. ?,1E0 m tyrf 2�71 Er TESTING 6 ENGINEERING SERVICES, INC. FIELD DENSITY TEST REPORT Client: Lazaro Morales Date: May 20, 2022 1001 SW 38t' Terrace Job: D - 2205255 Miami, F133165 Project Name: Residence — Addition _ f Project Location: 730 NE 101st Street., Miami Shores, Fl _ _PROCTOR DATA Proctor Max. Dry Optimum No. Soil Description Densi ct) Moisture _(%) 113456 _ Brown Sand with Gravel 112.7 10.1 I. Required Com action (%) 95% Test Depth Penetration inches): 12" FIF,I,D DENSITY TEST RESULTS Test No. Proc. No. Test Location Lift No. Dry Density % Moist. % I Com Result 1 113456 Northeast Area on Column Pad Footing 107.8 9.3 95.7 Pass 2 113456 Southeast Area on Column Pad Footing 108.0 9.1 95.9 Pass 3 113456 Southwest Area on Column Pad Footing 107.7 9.7 „ 95.6 PuJJ j ::=EE I I Comments: 13370 SW 131s' Street, Suite 105, Miami, FL. 33186 (305) 259-9779 www.nelcotestinz com Iielco 1 -,.nelcotesting.com