RF-04-22-931 UPLIFTG A 1Z L A B
May 19, 2022
Isaac's Roofing & Insulation
17225 South Dixie Highway, Unit 200
Miami, FL 33157
RE: TILE UPLIFT TEST
PROJECT INFORMATION PROVIDED BY CLIENT:
65 NE 105 ST
Miami Shores, Florida
Parcel ID 11-2136-006-0140
Permit #: RF-04-22-931
Date inspected: May 19, 2022
Date completed by: May 16, 2022
Roofing Contractor: Isaac's Roofing & Insulation
Carlab, Inc Project # 22-1284
Testing lab Certificate #: 19-0110.01
Dear Sirs,
In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof
Tile Uplift Test at the above referenced project. This testing was performed in general accordance with
Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of
mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was estimated to be less than 1500 square feet, and the mean
height of the roof is less than 45 feet above ground surface. The type of tile used for this project was
reported to be Crown Sanibel Concrete Flat Roof Tile. This tile was reported to have been foamed in
place.
At the time of this testing at least one test for every 100 square feet of roof tile in the perimeter area,
one test for every 200 square feet of roof tile in the field area, and one test per corner were performed.
The results for this report are valid at the time of testing only. Walking on the roof or any other type of
physical disturbance may alter these results.
Based on our test results, we conclude that the installation of the roof tile at the above referenced
project meets the test requirement outlined in the above mentioned protocol. Attached please find a
copy of our test report for your review.
Should -you have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
Respect f y submitted,
72,
Sergio Labiste, PE•617 3
8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
r-
N SCALE: N.T.S.
L
28
_ I
+
+
+
+
+
+
(Y)
+
u-)
+
i
+
+
LEGEND
+
FIELD TEST
-
PERIMETER
TEST
O
CORNER TEST
C A R L A B,
I N
C.
CBRTn'=&TF OF ASTT'HOR12ATLON 6419
WM &W. v Or. 1QANX PL 33165 TEA 395 203S12< FAffi 393
32"M
APPR❑X,
ROOF
TEST
L❑CATI❑NS
AND
DIMENSI❑NS