RF-04-22-931 UPLIFTG A 1Z L A B May 19, 2022 Isaac's Roofing & Insulation 17225 South Dixie Highway, Unit 200 Miami, FL 33157 RE: TILE UPLIFT TEST PROJECT INFORMATION PROVIDED BY CLIENT: 65 NE 105 ST Miami Shores, Florida Parcel ID 11-2136-006-0140 Permit #: RF-04-22-931 Date inspected: May 19, 2022 Date completed by: May 16, 2022 Roofing Contractor: Isaac's Roofing & Insulation Carlab, Inc Project # 22-1284 Testing lab Certificate #: 19-0110.01 Dear Sirs, In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was estimated to be less than 1500 square feet, and the mean height of the roof is less than 45 feet above ground surface. The type of tile used for this project was reported to be Crown Sanibel Concrete Flat Roof Tile. This tile was reported to have been foamed in place. At the time of this testing at least one test for every 100 square feet of roof tile in the perimeter area, one test for every 200 square feet of roof tile in the field area, and one test per corner were performed. The results for this report are valid at the time of testing only. Walking on the roof or any other type of physical disturbance may alter these results. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirement outlined in the above mentioned protocol. Attached please find a copy of our test report for your review. Should -you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respect f y submitted, 72, Sergio Labiste, PE•617 3 8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438 r- N SCALE: N.T.S. L 28 _ I + + + + + + (Y) + u-) + i + + LEGEND + FIELD TEST - PERIMETER TEST O CORNER TEST C A R L A B, I N C. CBRTn'=&TF OF ASTT'HOR12ATLON 6419 WM &W. v Or. 1QANX PL 33165 TEA 395 203S12< FAffi 393 32"M APPR❑X, ROOF TEST L❑CATI❑NS AND DIMENSI❑NS