RC-11-21-3128 SPECIAL INSPECTION1985 South Ocean Dr. Suite GL-3 Hallandale Beach, FL 33009 April 20, 2022 Inspection Report 21366-01 CLIENT: HRT Construction Group ATTENTION: Contractor / Owner SPECIAL INSPECTION REPORT PERMIT M RC-11-21-3128 PROJECT: 21366 10634 NE 11 th Ave Miami Shores, FL 33138 Main: (954) 591-8361 Fax: (954) 591-8361 Services@NOHMIS.com www.NOHMIS.com As requested, a representative of NOHMIS, LLC (NOHMIS) visited the subject site to do a visual inspection of the placement of the field welds of structural steel support elements. This report outlines our findings. PROJECT'S REFERENCED DOCUMENTS 1. Structural Floorplan submitted within Permit Package 2. Florida Building Code 71 Ed (2020) DESIGN MODIFICATION 1. Per city inspector's request, we have reviewed the site condition of the bolt holes. Use of (2) 1-7/8" diameter x 1/8" thick washers are acceptable with the spacers (as inspected) inserted inside the steel holes. 2. Structural steel plates required to develop the bending resistance are the 8x8x1/2" plates on both sides of the existing RC beam with the through bolts as noted on the plans. The plate underneath the beam is for stability and continuity and is not part of the structural capacity requirement. Therefore, tack welds of the plate as inspected are acceptable. INSPECTION RESULTS: PASSED On April 5, 2022, our representative visited the subject site and conducted visual observations. Visual observation of the placement of structural steel installation bolting and welds was conducted. The work listed was found to be in substantial conformance with the project's reference documents. Contractor may continue work with the local building department approval. Feel free to contact our office at 954-591-8361 anytime for further questions and/or comments with regards to this Project. RespeFSimhon, Josep PE PE 86388 Principal Joe@NOHMIS.com 954-591-8261 Ext 702 ��155nuururr�r� Digitally signed ,''`�oS�P" sry•..,` by Joseph -*. No.86388 *� Simhon STATE OF Date: 2022.04.26 R1 a..G X,:` ' 11:30:37 -04'00 CA FL 33057 Report #21366-01 Page 1 of 1 Miami Shores Village - BUILDING DEPARTMENT 10050 NE 2 Ave Miami Shores, FL 33138 305-795-2204 www.msvfl.gov NOTICE OF EMPLOYMENT AS SPECIAL INSPECTOR Process Number: RC - 11 - 21 - 3128 I (We) have been retained by HRT construction Group to perform special inspector services under the Florida Building Code 71" Edition (2020) and Miami Dade County Administrative Code at the 10634 NE 11th Ave Miami Shores, FL 33138 project on the below listed structure as of 12/14/21 (date). I am a registered architect/professional engineer licensed in the State of Florida. Special Inspector for Reinforced Masonry, Section 2122.4 of the FBC 7T" Edition (2020) Miami Dade County Administrative Code, Article II Section 8-22 Special Inspector for _ Trusses > 35 ft. long or 6 ft. high V5teel Framing and Connections welded or bolted Per city inspector's request. _ Soil Compaction Precast Attachments Roofing Applications, Lt. Weight. Insul.Conc. Other Note: Only the marked boxes apply. The following individual(s) employed by this firm or me is authorized representative to perform inspection* 1. 2. 3. 4. *Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a professional engineer or architect: graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination; or registration as building inspector or general contractor. I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel performing inspection services. I (we), understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site for reference by the Miami Shores Building Department Inspector. All mandatory inspections, as required by the Florida Building Code must be performed by the Miami Shores Building Department. Inspections performed by the Special Inspector hired by the owner are in addition to the mandatory inspections performed by the department. Further, upon completion of work under each Building Permit, I will submit to the Building Inspector at the time of the final inspection the completed inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and professional judgment those portions of the project outlined above meet the intent of the Florida Building Code and are in substantial accordance with the approval plans. Digitally signed �a!V1'I yam'-.,� Name Joseph Simhon, PE Sig&PA109f5PMdd ;' No. 86388 '; . � Engineer / Architect - Print Simhon STATE OF Address 1985 South Ocean Dr Suite GL-3, Hallandale Beach, FL 33009 ' 11:29:48 -04'00 ., r''pnrrunp Rev10082021 Special Inspector Notice Page 1 of 1