RF-03-20-638 INSP AFFIDAVITRemberto Contreras P.E. #21522 7066 SW 44 ST., Miami, Florida 33155 PI -I: 305-256-2416 INSPECTION REPORT July 13, 2020 Village of Miami Shores Building Department 10050 NE 2nd Avenue Miami Shores FL 33138 CONTRACTOR: ALPHATECH ROOFING PERMIT#: RF0320638 JOB SITE: 85 NW 103 ST., Miami Shores, Florida After a visual inspection performed at the above referenced location and photos provided by roofing contractor. My statement is based on the following details: Visual observation of existing roof, pictures provided by roofing contractor and test done using a Scanner Bosh and to examine the construction method employed. To verify the concealed Tin Cap on the wood deck area our office performed a Metal detector inspection to verify pictures provided. The inspection was performed utilizing a Metal detector Model Scanner Bosh. This instrument is a non-destructive testing system, and is capable of locating and identifying the concealed Tin cap. The metal detector scan as performed according to ASTM D7046. A Flat Roof with SIope 1/8:12 was observed with Base Shcct 1 l'ly ,i75 1 1 /4 RS attach with nails 5/8 tin cap space to 9 OC @ LAP 2 ROWS @ 9 OC at field, 6 0(' 'ci; I_AP 4 ROWS c) 6 OC at Perimeter and 6 OC @ LAP 4 ROWS @ 6 OC at corner, 9" strip over drip metal, 1 Ply Ruheroid 20 1-lot Mop and Mineral Cap sheet Hot Mop with granules. It is my professional judgment than the above mentioned proicct is in compliance with the requirements under the FBC2017. If I could be of any further assistance in this matter plcasc do not hesitate to contact me. Sincerely, Rembea nt e P.E.# ff11111 i ! 1 i Itlt�� Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # Z �— 03 — - -f .3 8 INSPECTION AFFIDAVIT DATE: I �', A k r r { licensed as a (n) Contractor / Engineer / Architect, (print name and circle License Type) FS 468 Building Inspector License #: C C C___� On or about LA 1.2 2 2c.2n IVC ' r�r V` I did personally inspect the roof deck nailing (Date 8 time) 44 work at l47 1 O , ��T r Vj i,.Q M �� }tii3 �� �L (Complete Job Site Address) Based up n that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual( ased or 553.844 F.S) .1 (44VA— Signature � -A State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned, Sworn to and subscribed before me this Notary Public, Sate of Florida at Large 2 Z da, of �t-V & y 70 wi — — ;�r— �y.�; HARVEYGUTI_:E=_ '+ ; si 4 s Notary Public - State c` r—mnsior s GG 929' 4 My Comm. 7--Jvr: 9or•Ced through National Notary Ass, 'General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an Inspection, Include photographs of each plane of the roof with permit # and address # dearly shown marked on the deck for each inspection oo A-1— nr+nnnUIrM nnno