RF-20-02-415 UPLIFTAFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY
WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -BUILT
SINGLE FAMILY RESIDENTIAL STRUCTURES
PURSUANT TO SECTION 553.844 F.S.
To: Miami -Dade County Building Department
11805 Coral Way, Suite 111
Miami, FL 33175
Re: Owner's Name
Property Address 16'6 r 14 �
Roofing Permit-Rurbber
--bear-Building Official:
I in i certify that the roof decking attachment and fasteners have been
strengttVned and corrected and a secondary water barrier has been provided as required by the "Manual
of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Structures" adopted by the
Florida Building Commission by Rule 9B-3.047 F.A.C.
of Qualifying Agent
STATE OF FLORIDA COUNTY OF MIAMI-DADE
Sworn to and subscribed before me this
day of '' 1�0) , 20
(SEAL) , p JOSE MAR11NEZ
Cammbdon 0 00 256902
* Explfas Seplambar 10, 2022
Personally kriOVVffF1'6' E91ld�dfleYEugIK 7 +
or Produced Identification
Q1Da.MWbeo6 Setby4feilbiq AlfiNvit Qmpliw,026 Mibbe
•M
AL132 Engineering Inc.
Testing & Engineering Service
Certificate of Authorization # 8131
Tel: 954.245.8976; Fax: 954.301.7776
5230 NE 18 Avenue, Fort Lauderdale, FI 33334
Roof Tile Uplift Test Report
i
Attention: Miami Shores Village, Building Department
10050 NE 2nd Ave, Miami Shores, FL 33138
Client: Toledo Builders Inc.
Test Date: 07/07/2020
Permit # RF-02-20-415
Property Address: 10635 NE 10" Court, Miami Shores, FI
Roof Pitch: Type of Tile: Roof Area:
4 in 12 Boral Roof Tile 31.00 squares
Tile Attachment Method:
Two Component Polyurethane Foam Adhesive -Poly Pro AH 160
Field Instrument :
IMADA Force Gauge 0-100 Serial number: 243454
Test Location
Total Number of Tests Field Uplift Pull Test
Test results
Perimeter Area: 14.00 (Ti-T14)
14 As per FBC 2017
Passed
Field Area: 17.00 (15-T32)
17 As per FBC 2017
Passed
No. of Corner: 8 (T33-T40)
8 As per FBC 2017
Passed
Ridge Areas: 170 pcs.(T41 T57)
17 As per FBC 2017
Passed
Important:
These laboratory results can change due to future weather impacts and/or unavoidable roof
traffic. Therefore, this report represents the TAS 106 results at the time of the test.
Please see attached a Roof Sketch for this project.
Cordially,
Engineering Inc. (NOA 09-1005.01)
onto Acevedo, PE
a. Reg. No: 36466
JUL 0 7 2020
rom
15
ACB2 Engineering Inc.
Engineering and Laboratory Services
5230 NE 181 Avenue
Fort Lauderdale, Florida 33334
Phone: (954)245-8976 Fax: (954)301-7776