Loading...
RF-06-20-1278 UPLIFTACB2 Engineering Inc. Testing & Engineering Service Certificate of Authorization # 8131 Tel: 954.245.8976; Fax: 954.301.7776 5230 NE 18 Avenue, Fort Lauderdale, FI 33334 Roof Tile Uplift Test Report Attention: Miami Shores Village, Building Department 10050 NE 2nd Ave, Miami Shores, FL 33138 Test Date: 08/24/2020 Permit # RF-06-20-1278 Property Address: 873 NE 96 Street, Miami Shores FI Roof Pitch: Type of Tile: Roof Area: 4 in 12 Ceramica Verea Roof Tile 27.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro AH 160 Field Instrument : IMADA Force Gauge 0-100 Serial number: 243454 Client: On time Roofing Test Location Total Number of Tests Field Unlift Pull Test Test results Perimeter Area: (T1)-T10)10.00 sq 10 As per FBC 2017 Passed Field Area: (T11-T27)17.00 sq 17 As per FBC 2017 Passed No. of Corner (T28-T33) 6 8 As per FBC 2017 Passed Ridge Areas: (T34 T48)146 pcs 15 As per FBC 2017 Passed important: These laboratory results can change due to future weather impacts and/or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. CordiAl AC ngineering Inc. (NOA 19.0918.01) A o Acevedo, PE Fla. Reg. No: 36466 AUG 2 4 2020 ACB2 Engineering Inca Engineering and Laboratory Services 5230 NE 181 Avenue Fort Lauderdale, Florida 33334 Phone: (954) 245-8976 Fax: (954) 301-7776 ti7 2$ '2A 30