Loading...
RC-07-20-1478 JOIST REPAIRSJOHN H. BUSCHER, P.E. STRUCTURAL • CIVIL CONSTRUCTION MANAGEMENT August 18, 2020 Miami Shores Village Building Department 10050 NE 2"d Ave Miami Shores FL 33138 Re: Residence at 1516 NE 1041h Street, Miami FL Concrete Restoration and Repair of Observed Underside Floor Joist Spalling and Associated Corrosion of Steel Reinforcing Bars. Permit #RC-07-20-1478 Site Inspection #2; Final Inspection of Completed Joist Repais Building Official, Per the request of the contractor Snapp Industries, on 8-12-20 I inspected the completed concrete repairs scope of work at the existing concrete floor joists deteriorated bearing ends. I find that, to the best of my professional judgement, the inspected joists have been repaired in accordance with the approved plans and the Florida Building code 2017 6t1 edition. If you have any co,, g+ ' ions regarding this inspection report, please contact my office. �I����,�i Sincerely, ! - 4AB44 f lohn H. Busc "d� CLOR\q �� •- ,. Tt� ,,,....,....�`���.- FL PE #41844 .ffr'rl FSSI O N ��-• ' •.�`'• Copy to: Owner, Contractor — Snapp Industries 4404 S.W. 139TH COURT, MIAMI FLORIDA 33175 TEL. 305-554-9170 EMAIL JBUSCHER@BELLSOUTH.NET JOHN H. BUSCHER, P.E. STRUCTURAL • CIVIL CONSTRUCTION MANAGEMENT August 12, 2020 Miami Shores Village Building Department 10050 NE 2"d Ave Miami Shores FL 33138 Re: Residence at 1516 NE 1041h Street, Miami FL Concrete Restoration and Repair of Observed Underside Floor Joist Spalling and Associated Corrosion of Steel Reinforcing Bars. Permit #RC-07-20-1478 Site Inspection #1; Inspection of Joist Repair Preparations Building Official, Per the request of the contractor Snapp Industries, on 8-12-20 I visited the above referenced property to inspect the concrete repair preparations to the existing concrete floor joists bearing ends requiring repair. The concrete joist ends have been chipped out as required to remove spalled or cracked concrete, leaving the intact joist bottom reinforcing bars, as per the concrete restoration details indicated on the approved plans. The inspected preparation work is approved for the application of Armatec 110 rebar coating, bonding agent and placement of shotcrete applied concrete or repair mortar. If you have any comments or questiions regarding this inspection report, please contact my office. Sincerely, L.�` 4 • • .t ,, Uc N0. 4 '(94 . cr �+•c�!, ,q7t John H. Busche , P�_�•. ��0 �� FL PE #41844 ;f�d�f•.hh RlCtA011 •.���•� 1)IIIIiI4Ij%1 %\ Copy to: Owner 4404 S.W. 139TH COURT, MIAMI FLORIDA 33175 TEL. 305-554-9 1 70 EMAIL JBUSCHER@BELLSOUTH.NET