RF-05-19-1177 UPLIFTACB2 Engineering Inc. Testing & Engineering Services Certificate of Authorization # 8131 Tel: 954-245-8976 Fax: 954-301-7776 5230 NE le Avenue Fort Lauderdale, FL 33334 Roof Tile Uplift Test Report Attention: Miami Shores Village, Building Division, 10050 NE 2nd Avenue, " - -ni Shores, FL 33138 Client: Roofing Test Date: 07/08/2019 Property Address: # RF-05-19-1177 _-:� 52 NE 98 Street, Miami Shores, FL Roof Pitch: Type of Tile: Roof Area: 4 in 12 Verea Roof Tile 5.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive -Poly Pro H 160 Field Instrument : IMADA Force Gauge 0-100 Serial number: 243454 Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: (T1-T2) 2.00 sq. 2 As per FBC 2017 Passed Field Area: (T3-T5) 3.00 sq. 3 As per FBC 2017 Passed No. of Corner (T6-T9) 2 2 As per FBC 2017 Passed Ridge Areas: (T10-T12) 26 pcs 3 As per FBC 2017 Passed Important These laboratory results can change due to future weather impacts and/or unavoidable roof traffic. Therefore, this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordially, _- - - _ ACB gineering Inc. (NOA09-1005.01) i Acevedo, PE F eg. No: 36466 6)/o8)z.or9 I. ACB2 Engineering Inc. Engineering and Laboratory Services 5230 NE 1811 Avenue Fort Lauderdale, Florida 33334 Phone: (954) 245-8976 Fax: (954) 301-7776 r 30 'J- v ACB2 Engineering Inc. Engineering and Laboratory Services 5230 NE W' Avenue Fort Lauderdale, Florida 33334 Phone: (954) 245-8976 Fax: (954) 301-7776 1 7