WS-03-20-503 WINDOW INSPJuly 22, 2020 Miami Shores Village Hall Building and Zoning Department 10050 NE 2ND Avenue Miami Shores. FL 33138 Attn: Building Official Re: Window Buck Modifications Project: Melisa Mosheim 675 Grand Concourse Miami Shores, FL 33138 Dear Sir, Edward A I_ANDEfIS, PE L6YSUlf'N5 EN61NFEAS Permit # WS-03-20-503 We inspected the installation of the window frames into the existing precast concrete frames that are integral with existing masonry structure. The installation of the new windows creates a gap between the aluminum frame and the concrete frame. As result, a portion of the attachment screws are exposed at the frame. We recommend filling the gap with a high strength concrete mix between the aluminum frame and the concrete frame. The aluminum frame is powder coated which provides a barrier between the direct contact of aluminum to concrete. When the concrete cures, and the installation screws are secured, the window assembly will able to withstand the wind pressures as required. All work will be compliant with the approved plans as well as the 2017, 6'h Edition, Florida Building Code. Please call if we can provide a 1�rf}formation. 0 44,' Very truly ours. EN' F . y 0 38398 Ed and A. Landers, = 1 s srATE OF �S4 S'Ft4RIDN 11";fIO vA iyENG►�'� 7850 NW 146TF' STREET, SUITE 509* MIAMI LAKES FL 33016 *PHN: (305)823-3938 *FAX: (305)823-9355