141 NW 96 ST FIELD DENSITY-G~EOTEC
FIELD DENSITY TEST OF COMPACTED SOILS
ASTM D-6938-08a
PROJECT: RESIDENCE RENOVATION AND ADLIFFIONS A"I':
141NW96ST
Date: March 28, 2022
GEOTE ' No. 1)-220328-002
MIAMI SHORES, FL 33150
MOIST1IRE DENSITY RELATIONSHIP (MODIFIED PROCTOR) ASTM D-1557-07
GAUGE SERIAL
SOIL DESCRIPTION
MAX. DRY
OPTIMUM
No.
DENSITY
MOIST. %)
62691
SAND GRAVEL
112.1
7.8
REQUIRED COMPACTION (%) 95% I TEST DEPTH PENETRATION (INCHES) 12
ORGANIC %
N/A
MATERIAL ON SITE
BACKFILL
I
I SUB -BASE
I
I BASE
B. PAD
B. SLAB
X
LIFT
FINAL
I EXC.
j X
I IMPORT
SOURCE
OTHER
u711►`f.`Irrtvlrll.`r■NOI.YIINr.`I
TEST
No.
LOCATIONS
FIELD DRY
DENSITY
FIELD (%)
MOIST.
FIELD (%)
COMP.
RESULTS
I
CENTER AREA OF LEFT ADDITION
107.7
5.7
96.1
PASS
2
CENTER AREA OF RIGHT ADDITION
106.9
6.1
95.4
PASS
3
4
5
NOTE:
Sieve Size: 3" 2'/,"
2" 1%"
1"
'/. /:"
3/8" 94
% Passing
Sieve Size:
% Passing
113.00
112.00
u
111.00
u
a
110.00
109.00
z
w
o} 108-00
107.00
106.00
1 105.00
MOISTURE / DENSITY CURVE
6.67%
7 87% 9.09% 11-63%
MOISTURE CONTENT %
R>spoctfully 56bmil�d
GEOTEC CONSULTING QUOUP CORP.
ldi jjart ar la, P.E.
Profession r" i SG712
Staten Flvrido
GEOTECHNICAL , CIVIL STRUCTURAL ENGINEERS — 13093 SW 133 CT. MIAMI , FL 33186 - P: (786) 319-0355 / P: (786) 380-0734
garcia5229@bellsouth.net
Notice of Preventative Treatment for Termites
(As required be Florida Building Code (FBC) 104.2.6)
ABOVE ALL PEST CONTROL SERVICES 786.419.3962M104,
A l L r 4 (--L 3 1? /.501
Address of Treatment or LtBlock of Treatment
�a
Date
Cyper TC
Product Used
CIS Gam_.
Percent of Concentration
Time
Cypermentrin
Chemical used (active Ingredient)
0 Q1
Area treated (Square feet)
R. ALCANTARA
Applicator
—2
Number of gallons applied
Linear feet Treated
Stage of Treatment (Horizontal, Vertical, Coining Slam, retreat disturb areas)
As per 104.2.E-If soil chemical barrier method for termite prevention is used, final exterior treatment
shall be completed prior to final building approval.
If this notice is for the final exterior treatment, initial and date this line