141 NW 96 ST FIELD DENSITY-G~EOTEC FIELD DENSITY TEST OF COMPACTED SOILS ASTM D-6938-08a PROJECT: RESIDENCE RENOVATION AND ADLIFFIONS A"I': 141NW96ST Date: March 28, 2022 GEOTE ' No. 1)-220328-002 MIAMI SHORES, FL 33150 MOIST1IRE DENSITY RELATIONSHIP (MODIFIED PROCTOR) ASTM D-1557-07 GAUGE SERIAL SOIL DESCRIPTION MAX. DRY OPTIMUM No. DENSITY MOIST. %) 62691 SAND GRAVEL 112.1 7.8 REQUIRED COMPACTION (%) 95% I TEST DEPTH PENETRATION (INCHES) 12 ORGANIC % N/A MATERIAL ON SITE BACKFILL I I SUB -BASE I I BASE B. PAD B. SLAB X LIFT FINAL I EXC. j X I IMPORT SOURCE OTHER u711►`f.`Irrtvlrll.`r■NOI.YIINr.`I TEST No. LOCATIONS FIELD DRY DENSITY FIELD (%) MOIST. FIELD (%) COMP. RESULTS I CENTER AREA OF LEFT ADDITION 107.7 5.7 96.1 PASS 2 CENTER AREA OF RIGHT ADDITION 106.9 6.1 95.4 PASS 3 4 5 NOTE: Sieve Size: 3" 2'/," 2" 1%" 1" '/. /:" 3/8" 94 % Passing Sieve Size: % Passing 113.00 112.00 u 111.00 u a 110.00 109.00 z w o} 108-00 107.00 106.00 1 105.00 MOISTURE / DENSITY CURVE 6.67% 7 87% 9.09% 11-63% MOISTURE CONTENT % R>spoctfully 56bmil�d GEOTEC CONSULTING QUOUP CORP. ldi jjart ar la, P.E. Profession r" i SG712 Staten Flvrido GEOTECHNICAL , CIVIL STRUCTURAL ENGINEERS — 13093 SW 133 CT. MIAMI , FL 33186 - P: (786) 319-0355 / P: (786) 380-0734 garcia5229@bellsouth.net Notice of Preventative Treatment for Termites (As required be Florida Building Code (FBC) 104.2.6) ABOVE ALL PEST CONTROL SERVICES 786.419.3962M104, A l L r 4 (--L 3 1? /.501 Address of Treatment or LtBlock of Treatment �a Date Cyper TC Product Used CIS Gam_. Percent of Concentration Time Cypermentrin Chemical used (active Ingredient) 0 Q1 Area treated (Square feet) R. ALCANTARA Applicator —2 Number of gallons applied Linear feet Treated Stage of Treatment (Horizontal, Vertical, Coining Slam, retreat disturb areas) As per 104.2.E-If soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. If this notice is for the final exterior treatment, initial and date this line