MCC-19-1825Permit No.: MCC-08-19-1825
Miami Shores Village Permit Type: Mechanical - Commercial
10050 NE 2 Avelp@ Miami Shores FL 33138 work Classification: A/C Replacement
305-795-2204 Permit Status: Approved
Issue Date:08/09/2019 Expiration: 02/05/2020
Location Address Parcel Number Project
11300 NE 2ND AVE, Miami Shores, FL 33161 1121360000050 BARRY UNIVERSITY
Contacts
BARRY UNIVERSITY INC Owner
BARRY UNIVERSITY
11300 NE 2 AVE, MIAMI SHORES, FL 331616628
SMART AIR SYSTEMS INC Contractor
STEVEN CHARNEY
Business: 9549681288
Inspection Requests:
Description: REPLACE (3) ROOFTOP PACKAGE A/C UNITS Valuation: $ 132,000.00 Inspection Re
LANDON HALL
Total Scl Feet: 0.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$79.20
DBPR Fee
$69.30
DCA Fee
$46.20
Education Surcharge
$26.40
Permit Fee
$4,570.00
Scanning Fee
$9.00
Technology Fee
$115.50
Total:
$4,965.60
Payments
Date Paid Amt Paid
Total Fees
$4,965.60
Credit Card
08/09/2019 $4,915.60
Check # 8519
08/07/2019 $50.00
Amount Due:
$0.00
Building Department Copy
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFF cert' at all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating co sd�t[1Ap a oning. Futhermore, I authorize the above named contractor to do the work stated.
/ Applicant / Contractor / Agent Date
August 09, 2019 Page 2 of 2
gl�l�9 -l1H
BUILDING
PERMIT APPLICATION
Miami Shores Village u*c
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972 BY
INSPECTION LINE PHONE: NUMBER: (30S) 762-4949
FBC 20
Master Permit No. H C C " 0
Sub Permit No.
BUILDING M ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [RENEWAL
PLUMBING rQ MECHANICAL FIPUBLIC WORKS ❑ CHANGE OF (] CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 11300 NE 2nd Avenue - L,&rAQr,�0tj\
City: Miami Shores County Miami Dade Zia: Z3NL.o l
Folio/Parcel#: Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): Barry University Phone#:
Address: 11300 NE 2nd Avenue
City,: Miami Shores State: FL Zip: 33161
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: Smart Air Systems, Inc. Phone#: 954-968-1288
Address: 1731 Banks Road
City: Margate State: FL 33063
Qualifier Name: Steven Chamey Phone#: 954-968-1288
State Certification or Registration #: CAC056916 Certificate of Competency N:
DESIGNER: Architect/Engineer:
^UUMM".
tale: Zip:
Value of Work for this Per It: $ 132,000.00 , Square/Unear Footage of Work:
Type of Work: ❑ Add ation ❑ New ff Repair/Re lace p ❑ Demolition
Description of work: replace (3) rooftop package a/c units
Specify color of color thru tile:
Submittal Fee $ Permit Fee $ CCF $ CO/CC $
Scanning Fee $
Radon Fee $
DBPR $ Notary $
Technology fee $ Training/Education Fee $ Double Fee $
Structural Reviews $
Bond $ �' • F' v
TOTAL FEE NOW DUE $ _ _
iRev&- 02/24/20t4)
Bonding Company's Name (if applicable)
Bonding Company's Address
city
State
Mortgage lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.. —
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with on estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien low brochure will be delivered to the person
whose property is subject to attachment Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issu d. in .ebee�Ce of such posted notice, the
inspection will not be approved and a reinspection fee will be charged. 1
OWNER or AGENT
The foregoing instrumJ�en was acknowledged before me this
day of M 20 19 by
Lau V who is personally known to
r
. me or who has produced
identification
and who did take an oath.
NOTARY PUBIC: --r— )
80a Nowt 12,2022
illaMl ftTMFib1r11O101i00.WM
as
The foreg ng instrument was acknowledged before me this
day of4w--
_...�_. , 20 /9 , by
who is personally known to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
aaaaaaras♦aaasaaaaaaeaaasaaa aaaa as sari raaaaaaaaaaaaa�
APPROVED BY AlaExaminer
Structural Review
' CARMLKOPK9i
myc0wAWIONiFF972221
DI W-. MsyA 2=
BondedlNu Notary POI& MOIN01"
aaaaaarasaaaaaaasaaaaaa+aaaasaaaasaaaaa•
Zoning
Clerk
(RevisedO2/24/2014)
S
I.AT IT #: -08-11-182
'.'ipmi Shores Village
_
^-1nVED_. BY DATE
F Mia i Shores Village
u g Department
G DE'T4 0 N.E.2nd Avenue
�U" LCT i O CCNIPUANCE WI m ALL FEU i�AL S o� s, Florida 33138
T : (305) 795.2204
aTF AN,) l C INN i °f rtl,L�5 AP10 REGULAT'OMS F :(305) 756.8972
AIR CONDITIONING REPLACEMENT DATA
PERMIT NUMBER: MC
This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must
be on its own data sheet. Multiple units on single sheets are not acceptable.
Job Address (where the work is being done):_ 11'Snc Z4f-'-sye C,yf1 "I
City: Miami Shores Village County: Miami Dade Zip Code: 33l�tO2
. . .... ......
ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CET&SW
ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEV#jjQK •
A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS • . • • 000000
•
AHRI DATA SHEET REQUIRED
.... .........
...... ... . .....
.. ..
Change disconnecting means: YES ❑ NO ❑ ARHI Sheet Attached: YES ❑ NO ❑ Con;r0 Attached:.YES. .....
. .
UNIT BEING REPLACED
DATA
. NEW UNIT;
MANUFACTURER
•
••
AHU or PKG. UNIT MODEL #
COND. UNIT MODEL #
KW HEAT
NOM TONS
AHU
CU
CPKG iU
1) M.C.A
AHU
CU PKG
(L'7U
AHU
CU
PKG a7i U (O
2) M.O.P
AHU
CU(PKG"
Q?v
AHU
CU
PK Q IR
3) VOLTS
AHU
CU KG
jt;�U
PKG UNIT /
j
PKG UNIT
EER/SEER
YES
NO
REPLACING DUCTS
YES
NO
YES
NO
REPLACING THERMOSTAT
YES
N
YES
NO
NEW 4"CONCRETE SLAB
YES
YES
NO
NEW ROOF STAND
YES
YES
NO
NEW RETURN PLENUM BOX
YES
N
1. Minimum Circuit Ampacity (Wire Size): IA!A �
T
2. Maximum Overcurrent Protection (Fuse/Breaker Size): .)Q Q.Tj% g
3. Voltage of Circuit (208/240/480): A(co�sjtob
4. Size Disconnecting Means:
Contractor's
State Certi&
Signature
(Revised02/24/2014)
Certificate of Competency No.
Date: /Z6,
JVIM{.IV1' •.I I�aMIp
Air Handling Unit
Performance Report
Job Summary
Project Name: Barry U (Landon RTU Rplcmts)
UnitTag(s): AHU-5, AHU-6, AHU-8
Quantity: 3 Environment: Outdoor
Unit Overview
Model Cabinet Performance Airflow (CFM) Altitude (ft) Weight (lbs)
XTO-45x63 Solution 5,000 10 2,526
Segment Sequence
• • • •
. .
....
......
(FS EH CC FMB
"
" •
�"
Unit Construction
......
....
....
. .
Casing Details
....
••••••
....
•••
.....
•••••
• • • •
Insulation • •
' • •' • •
Segment
Thickness (in)
Exterior Gauge and
Exterior Paint
Interior Gauge
a C' :Thickness avid
Bulkhead,
Bulkhead, •
Material
and Ma�e'i
• •
Material •
•
• • •. • •
FM, CC, EH, FS
2
STD Exterior Paint
STD Ga. G-90
STD Ga.,G-90.
2" Foam "
Galvanized •
Galvanized
Galvanized'
..
Base Details "
• • • •
Base
Floor
Segment
Gauge and
Gauge and
Thermal
Tread
Material
Paint Material
Paint
ti
Insulaon Break
Attachment Plate
FM, CC, EH, FS
None
None STD Ga. G-90
None
N/A
None
Galvanized
Unit Electrical
Circuit Details
Circuit It Component V/Ph/Hz FLA (Amps) Minimum Current Maximum Overcurrent
Ampac" (MCA) Protection (MOP)
1 Supply Fan Motor Control, 460/3/60 31.6 39.5 40.0
Electric Heat
MlnimuriiUnitSCCRtt 5 kA rms Symmetrical ETLLabel (UL1995/NEC-2002) Yes
Unit Ught7ype Unit Ught Switch P-��,"'
Supply Fan(s)
Performance Details'`
Fan
Model
Class
% Wheel % Wheel Total Airflow
Size Quantity
Altitude (ft)
TSP ESP
Fan Speed
Fan Power
Manufacturer
Width Diameter (CFM )
(in w.g) (in w.g)
(RPM)
(BHP)
Comefri
ATZAF
S
15-15 100 100 1 5,000
10
2.76 1.50
1,981
3.62
Max RPM
BHP w/
WheelType
Wheel Fan Flow
Blade Type Base Material
Airflow
Inverter Drive
Isolation
Thrust
Drive Loss
Material Isolation
Monitoring
Balancing
Type
Restraints
2,900
3.88
Dwol
Airfoil Steel Galvanized Steel None
Yes
1" Spring
-
Project Name:Barry U (Landon RTU Rpicmts) V)J(1 Last Saved: 5/2/2019 3:26:33 PM
Unit Folder:AHUS Johnson Report Version: 2018.7.25.1519
Controls Software Version: 19.1.6378.15178
Page 1 of 7
0 TVKK
Ivnn JvIuuu1111 F-11Uu14
Air Handling Unit
+ Fan %Wheel; IDi% Wheel Total Airflow
Manufactured
Model Glaze , Size Width --ameter — Quantity
([FM)
Drive Type Drive SF Spas ►e Belts Spare Sheavel+lnlet ScreenI f Fan Cage, Bek Guard
Beft Drive - 1.5 - - - - Yes
Fixed
Type/MFG Motor V/ph/Hz QuantityI tnsulatio�
. .�Power(HP) — . _ _ _ _ - _ _ . --class_
TEFC/WEG 5.0 460/3/60 1 F
Water Coil(s)
• � 1Pa
a —
CC Water 5
RPM ,I Frame Size
1,800 184
Performance Report
Ahitude (ftY' "P— ESP ' Fan Speed fan Power
(in�w.g) (in w.g) (RPM) ($HP)
tube lines " Boarl,us Fan Motor ` SZMic
Stand Removal Rail I Snubber -
None - - - -
FLA (Amps) (^ Efficlency + 'Location
6.49 Premium Left
-( lr�Imp" am - on DB WB DB Irt W8 (GFM) (ft/mfn) Aru (GPMJ,6
14 10 240 154 81.0 68.0 52.5 51.8 5,000 403 0.75 34.0 • •44!0
SGR
! F) •Yei. , wPo � !
58.0 4.2 12.1. 44:
Location
c.onsztv_t.tion ueiaHs
• •.••.._•....'-•.•.•.•_ .I
Cory�aion�r .•:.•
_
Goo
Connection
Offset (in)
Connection Rotation
.•.:S. (Ply
Connection Typs 1, • (Per Coo) CoN StadcAaok•
Coll Mdex' Connection
MatertaP
��
(degrees)
( • Size 1 •
J�-•
CC
0 Left 0 Steel
0
MPT • •
-. 2) • • • • •
Coil!
�q of Co�Ns
Face f Total Fin Fin Length Coil Face
'�Type Height (in) {in) 1y Area (fN)�
Fin Material
IFin Thidmess
Fin s--:*0' • • • Tut�•y►all •
Type Tube Mater-ia�l� •
_Agh
Dfari�eteT (in; ThicknQss (in)
CC
1 Full 35.00 51 12.4
AL .010
Corrugated 1/2 Copp t' • .016
( Coit
�— !Dry "-� F-h-u e t
Coll Coating Dry Weight (Ru)
- - _ _(1�)
r--` .� '.
Fluid Volume (ft')
Lam_,
r-ia Intermediate Drain -Fouling Fa& j
Header Material) Casing Material J
,LPan Material 1(hr,f!!._ MT )
CC
- 234 61
1.0 Copper Galvanized 304 Stainless -
Steel
Notes
'Performance is shown for the entire coil bank. Performance is not per coil.
'Coil index indicates position in segment. Example: CC-1, index 0; Spacer, index 1; CC-2, index 2
'Johnson Controls suggests using red brass or copper connectors when the coil is to be attached to a copper or brass piping system.
All coils are rated with a fouling factor of 6'66&5 hr.ft:.'F/BTU unless otherwise noted
Ratings are for coils manufactured by Johnson Controls, Inc., 507 E. Michigan St., Milwaukee WI 53202.
Coil DLL Version: 7.7d.004
BDW Tube Spacing:1.25 x 1.08
CC[11(01: This coil is certified in accordance with the AHRI Forced -Circulation Air -Cooling and Air -Heating Coils Certification Program which is based
on AHRI Standard 410 within the range of Standard rating conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI
Directory at www.ahridirectory.org.
Drains}
Drain Pan i
Segment -
Liner Material Connection Location Liner Coating __ !
CC Stainless Steel Left None
Project Name:Barry U (Landon RTU Rplcmts) 1 I Last Saved: 5/2/2019 3:26:33 PM
Unit Folder:AHUS Johnson 0 Report Version: 2018.7.25.1519
Controls Software Version: 19.1.6378.15178
Page 2 of 7
a YUKK
Filter(s)
. v.�.� av+uay.. Ll luul a
Air Handling Unit
Performance Report
Segment Type—� Depth ' Filter Loading Media/MERV "- p of Spares �Spare Filter Media Frame Material
FM Primary 4" Side Pleated 30% (MERV 8) 1 Pleated 30% Galvanized
Filter (MERV 8)
Segment
FM
Dampers)
Primary Filter
20x24 4 12x24 2
Segment
Air Path
H x W (in)
Velocity CFM
FM
Outside
15.25 x
1,049 5,000
Air
45.00
FM
Return Air
15.25 x
1,049 5,000
45.00
Typo
Rana On
— —.L w4)—
Details
•
Allowable OA Damper Type'I Camper Model
,L Conte
•• •
+ Material
��• j kator.
"ntatid 11 Type
Fail •
1 Pdkik A
CFM_ l
• • • * •
.
Control 100% CD60
Galvanized
Parallel.... -
- Control 100% CD60
Galvaniz* ••
ParallPJ.•.
�'••'
••••••
:
••1••
•• ••
••
••••••
Hood(s) ••
Segment Air Path I Quantky I H x W (In) T Total Face Velocity (ft/min) II Airflow (CFM) rzz—felEli—mina-tor i Bird Screen
FM Outside Air 1 25.8750 x 1,049 5,000 - Yes
49.7020
Doors)
Segmenn
Location
J
�i
Swing
Hinge Location
-
EHx;�xTI(in)
,l
.. , _ Test
.View PorfN Port
FM�
left
Outward
Upstream Side
39 x 30 x 2
None -
EH
Left
Outward
Upstream Side
39 x 21 x 2
None -
FS
left
Outward
Upstream Side
39 x 18 x 2
None -
Electric Heat
Spare if Thermal
Gasket Beak
fety Noncontact Safety
tch Interlock
Qty Element yk►lta a k• Am �Gontro Min CFM
g M perage Draw KW K1N Ratan` Method EAT ('Fj tAT ('F) Stages
TYPR , - .... �. _ .�� Vokage�1. Required
1 Open 460 / 480 25.10 20 Standard KW Rating 0.00 12.77 None 24 VAC 1,646
` Pi Control Panel Mounting (` Control Interlocks Scree ►IeatTr Control
i ___._ ... yp_
None Standard Differential Pressure Switch and Dry Contact Interlock Outlet Full SCR Controller
Project Name:Barry U (Landon RTU Rplcmts) /Jj) j� Last Saved: 5/2/2019 3:26:33 PM
Unit Folder:AHUS Johnson 04 ` Report Version: 2018.7.25.1519
Controls Software Version: 19.1.6378.15178
Page 3 of 7
ia YUKK
1 V111% JVIt1tIV11 CIIt UIO
Air Handling Unit
Performance Report
_. Dis o nectSvriO`ch! SuPPh►.FusN+ NEM�itatin Contactor — --
t� d _ _ OPt�_ _ _ _Control Panel Options Control Panel Hariding—_
Non Fused None NEMA 1 Magnetic 0-10 VDC Left
Disconnecting
Motor Control(s)
v (Wput/Output Heat lass ' i
Segment rr Type ^ MMP V/Ph/Hz I Efficiency Enclosure
r Disconnect ' RFI/EMI EMC ,
Bass
Bypass
Amps. (at 100% load)
Tye pher_
FS ABB VFD - - 460/3/60 8.8/8.8 90 % 127 NEMA 311
- Non Fused Yes
Airmod AYK
Notes
'Drives are rated for use below 3,000 ft and 104'F. Use Derating Charts in Air -Mod Engineering Guide Form 100.42-EGI (212) for use above these
limits.
Storage Temperature: -40'F to 1587
Humidity: MAX 95% RH non -condensing
Altitude: 3,300 ft without derate (1% derate for each additional 330 ft.)
••••
Overload Current Rating:100% for 1 minute every 10 minutes.
*0*000
: . . 00
The Class SO trip rating of the MMP device will not withstand an across -the -line start of a fan and should not bg*t;ith VFti -bypass....
circuits.
with
The customer must provide a platform or catwalk for accessing the power -disconnect.
...•.••...•.
Copper Conductors Only.
* 0 0 ....
...• .....
FS: Contains the following option: Swinging DC Line Choke (Equivalent to 5% Input Line Reactor)
....
...... .. • . • • : • •
.• •. .. ..•..•
•
Face Velocity and Static Pressure
••""
_ Summary
— . _ �.--
Akflow I �� fan (
Se`ment 1�
Description !
tFace Area (sq. ft)
Fax Vebdty Fan Static
(CFM) , (R/mtn) �) Static(Pressu►e Pressure
�`
-_.
]Llln w.`.)_
FM Standard Hood 4.8 5,000
0.06 0.00
FM Bird Screen 4.8 51000
0.10 0.00
FM Opening 4.8 5,000
1,049 0.19 0.00
FM Control Galvanized (C060) 0.0 5,000
0.04 0.00
FM 4" Pleated 30% (MERV 8) 17.3 5,000
289 0.09 0.00
CC Cooling 5 rows 14 fins 12.4 5,000
403 0.75 0.00
EH Electric Heater 0.0 5,000
0.03 0.00
FS External Static - User Entered 0.0 51000
1.50 0.00
Tolal� 2.76', 0.00�
Dimensions and Weight
t
Details
Oescr�pfion -
— I --- le^6-
th ��ln) _
.L,Nildt:() �HelghtTTn}'�(,.—Weifi!tll.�...
FM
Filter / Mixing Box
33
63 45 478
CC
Variable Length'Cooling Coil
19
63 45 642
EH
Electric Heat
24
63 45 350
FS
Supply Fan
58
63 451,056.
Overa l
_ ice—
R 252b —j
Notes
The length includes bottom tier segments only
'The width does not include coil connection extensions or door latches that extend beyond the unit casing. The width does not include the depth
of any pipe chases.
Project Name:Barry U (Landon RTU Rplcmts) I )� I Last Saved: 5/2/2019 3:26:33 PM
Unit Folder:AHUS Johnson �� ll Report Version: 2018.7.25.1519
Controls Software Version: 19.1.6378.15178
Page 4of7
iii YUKK
Project Name:Barry U (Landon RTU Rplcmts) //ljl
Unit Folder:AHUS Johnson ',
Controls
1 VI�1� JVILILIVII LI IUUI d
Air Handling Unit
Performance Report
. .
....
......
......
...
......
....
....
. .
....
....
.....
......
... .
.....
....
..
......
. .
. .
......
Last Saved: 5/2/2019 3:26:33 PM
Report Version: 2018.7,25.1519
Software Version: 19.1,6378.15178
Page 5 of 7
ia YUKK
Air Handling Unit
Performance Report
Recommended Trap Height
Details
Fan TSP (in Positiveor Negative Calculated Dimensions (in) Calculated Dimensions (in) Base Rail
Segment Applicable Fan
w•E•) I ._ Height (in)
H r X - H— _A L H t x. —
cc Supply Fan 2.76 Negative 3.76 1.88 5.64 4.00 6.00 None
Negative Pressure Trap
H Z 1" + T.S.P. of downstream fan
X M %*H
Below
atmospheric
pressure
n
Drain mnrsctan
Xj
Atmospheric
pressure
. .
....
......
......
.. .
......
....
....
. .
....
....
.....
......
... .
.....
.. ..
..
......
. .
. .
......
Notes
Formulas and calculations are recommendations only. Contractor shall determine actual dimensions required for each trap based on jobsite
conditions, and application requirements.
Refer to the installation INenual of the IOM for more Information.
Statement of Compliance
i _ _ Details
YORK• Solution XT AHU's meet IBC seismic requirements for non -critical equipment (Ip = 1.0) for locations with design spectral response Sds <=
0.43. Units must be rigid mounted.
The anchorage of the unit to the ground or building structure needs to be evaluated by and is the responsibility of the engineer of record.
Specification of seismic requirements is the responsibility of the project design engineer. If formal certification is required, please contact your
sales representative and/or application engineer for review. Certain application and site requirements may require additional cost and/or lead
time.
Component locations are listed as Segment Hand (Unit Hand): ex. Left (Right). See SubmittalDrawing for additional details
Air handling unit parameters vary depending on conditions. Parameters such as airflows, air pressure drops, and coil capacities are shown for
design conditions.
Project Name:Barry U (Landon RTU Rplcmts) ,/J�J(Jf
Unit Folder:AHUS Johnson �Oj
Controls
Last Saved: 5/2/2019 3:26:33 PM
Report Version: 2018.7.25.1519
Software Version: 19.1.6378.15178
Page 6 of 7
rvr%n 4VIULIvrr crtuura
Air Handling Unit
Performance Report
Shipping Summary
Skid Skid length (in) I Skid Height (in)
(FS EH CC FM) __.. 155 51
tS1idHeight
Cabinet Height
�='Lq ; I i F I
4*- - Cabinet R idth
Skid Width On) Skid Weight (ibs)
�. Sl 2,525
g Taal Segment(s) Length
IF�
IA
Skid Length i • • •••• • ••••
•
.� Skid Width I • • • •
•••••• •• • ••••••
•
Notes •••• •••• • 1
Skid Width: Total width of the shipping skid, including any items that may extend beyond the cabinet (this includdlAthy door hatldlgs, coil
connections, drain connections, lifting lugs, mounted pipe -chases, electrical/control components, tie -down brackets! Zide dalhtggs).;
Skid Height: Total height of the shipping skid, including any items that may extend beyond the cabinet (this ineMdeSlany base -rails, sAipping wood: •
blocks, roof peak, discharge flanges, mounted gas -furnace flue pipes). 000060
• •
• •
Skid Length: Total length of the shipping skid, including any items that may extend beyond the cabinet (this includes atty mouiti"iLn-hoods • • • •
discharge flanges,tie-down brackets, shipping wood -blocks, front dampers, split connectors, electrical/control tomp8gents, outrigging exteruiorn 0
isolation dampers, inlet baskets). • • • • • • 0 • '
0000
Project Name:Barry U (Landon RTU Rpicmts)
Unit Folder:AHUS Johnson 61
Controls
Last Saved: 5/2/2019 3:26:33 PM
Report Version: 2018.7.25.1519
Software Version: 19.1.6378.15178
Page 7 of 7
Engineering Submittal
Wind Load Certification
16 ga Curb Adapter
Design Parameters:
FBC 2017 & ASCE 7-10
Wind Speed: 180
Exposure: C
Int. Pressure Coeff: 0
Cat: II
For Seacoast Curb Adapters only
BENCHMARK KiVC7IN£.£RING
OR THE TREASURE COAST I-I-C.
806 Delaware Ave. (772) 267-1399
Fort Pierce, =L 34946 benchmarkengineeringtcngmail.ton;
FL # P.E. 70878
. .
....
......
......
...
......
....
....
. .
.
.
....
....
.....
......
... .
.....
.. ..
..
......
. .
. .
......
N
i
g78 '
0
q t TPTE 0 2
O,t, E L ORS
30 N p►L �? ���
��itIr111�111\`
Job; bCcy (ty)i Ucr'S l k
4� F
Full perimeter
Welded,16 cia
GAv, 5teel
b V' C' x 16 qa
Welded perimeter
Gusset
ruplcal Curb Wall Retail
# 14 5M5
penetrate Acla
Min, 3 Thread
pr N
28" Max
..
fgpical Curb Wagrg�l
Notes; Curb Flange Octal
I . Fasteners; # 14 zinc plated, self tappinq sheet metal screws @ 4" O.C.
Fasteners shall penetrate thra curb adapter by a minimum of 5 threads.
3, Alternate Attachment: 16 Ga straps may be used @ 6" O.C. w/ ( 2)
# 14 5M5 into M & ( 2) # 14 9A5 into Fx. Curb
( 5ame quantity of fasteners required).
4. Attachment is for axrb adapter to M & curb adapter to existing curb Ay.
Existing arb to roof attachment by others.
Benchmark Engineering
of the Treasure Coast LLC =CCur�8o6 Delaware Ave.
Fort Pierce, FL 34950
.....
sees .
00 00
••
0000
• •
•0900
......
•0*
(iimensions
A-�
!/
V
n !!
C
P
o � tiGl i �11 rc�
\\/i
yso
0 0878
7
ATE O
Fs;'--LORID,'-�G`��
`'�►1l111��`'
Order (Ref) #: 19-8276
Contractor: Integrated Cooling Solutions
10405 NW 37th Terrace
Project Details: Barry University - Landon Hall
11300 NE Second Ave
Miami Shores FL
Miami FL
Other Structures Design Pressure Calculations
Rooftop Structures and Equipment
FLORIDA BUILDING CODE SIXTH EDITION (2017), Section 1620.6; ASCE 7-10 Section 29.5
Input Description
Exposure Category:
Vun (mph):
Cross -Section (Shape):
Structure Width (in):
Structure Height (in):
Mean Roof Height (ft):
Building Dimension Parallel to
Wind (ft):
Building Dimension Normal to
Wind (ft):
B
170
Square
134
45
40
100
289
Results
Loterol Force
Kd=
gz(lb/ft2)=
Ar(ft2)=
Lateral (GCf)=
Pressure (Ib/ft)=
Uplift Force
r •
••ice••
q: Ob1�tz1F• •
Ar•(ft;)~•
Vertical (d!,,)=*
Pressure (I04)= '
•
0.90
62.15
41.88
1.90
70.85
• p.X ea
62.15
,4, 11818 •
•1.+0 •
55.91 •
•
•
NOTES: Design is in accordance with ASCE 7-101A50 method) and the Florida Building Code Sixth Etlttion .Results are riot valid for use "le", .... ,
lid Only With Raised Engineer S
approved via original signature and raised engineer seal of a PE from Engineering Express. Selection & installation of products shall be appr .\ tic F - FL
slog these dimensions and presswes as verthed by other.
8/1/2 9
NO Dk�Be rdo, P.E.
• � PE46549
_ ��'
Note: For openings to be properly rated in Zone a, no part of Me opening shall be within CA: M85 — � � 1
v1.13 1605W 12TH AVENUE, SUITE 106, DEERFIELD BEACI0FLORIDA 33442 -
_ C_"
PHONE: (954) 354-0660 - i866_/�6-9999
ENGINEERINGEXPRESa..tCOM^'.• STATE OF
'�,SS'ONAL E�
Order (Ref) #: 19-8276
Contractor: Integrated Cooling Solutions
10405 NW 37th Terrace
Miami
Project Details: Barry University - Landon Hall
11300 NE Second Ave
Miami Shores
FL
Other Structures Design Pressure Calculations
Rooftop Structures and Equipment
FLORIDA BUILDING CODE SIXTH EDITION (2017), Section 1620.6; ASCE 7-10 Section 29.5
FL
Input Description
Results
Exposure Category:
B
Lateral Force
Vnit (mph):
170
Kd=
0.90
Cross -Section (Shape):
Square
qz (Ib/ftz)=
62.15
Structure Width (in):
134
z
Af(ft )=
41.88
Structure Height (in):
45
Lateral (GCf)=
1.90
Mean Roof Height (ft):
40
Pressure (lb/ftz)=
70.85
Building Dimension Parallel to
Wind (ft):
100
Uplift Force
• 0060
+
Building Dimension Normal to
•40 4111
•
Wind (ft):
289
.♦:�;•
♦•06%
.•
.:.
%
6245
•
•
AJ4f*' -.
.42.88
Vertical (VCl -_�
e1 e
• •
• • •
Pressure (TOT2j= •
55.54
•
DIGITAL SEAL �\ -
lid Only With Raised Engineer S
NOTES: Design ism accordance with ASCE 7-101AS0 method) and the Florida Bu4dmg Code Sixth Edition . Results are not valid for use unless
approved via origgin inal sgnature and raised engineer of a PE from Eneering Express. selection & In stallahucts on of prodshall p.ed
\ . •�`C E N
FL
using these dimensions and pressures as verified by others.
8/1/2019
In ank L. Bennardo, P.E.
PE0046549
PE46549
Note: For openings to be properly rated in Zone 4, no part of the opening shall be within
—
�; CA: g9885
v1.13 1bU 5W I Z I H AVtNUt, NU It IUb, Utt NFIt LU UtAlel, ELUISIUA 4t`lz, -
PHONE: (954) 354-0660 - (866) 396-9999, _)3—
ENGINEERINGEXPRESS.COM STATE OF
//// /ONAL
Order (Ref) q: 19-8276
Contractor: Integrated Cooling Solutions
10405 NW 37th Terrace
Miami
Project Details: Barry University - Landon Hall
11300 NE Second Ave
Miami Shores
FL
Other Structures Design Pressure Calculations
Rooftop Structures and Equipment
FLORIDA BUILDING CODE SIXTH EDITION (2017), Section 1620.6; ASCE 7-10 Section 29.5
Input Description Results
Exposure Category:
B
Umt (mph):
170
Cross -Section (Shape):
Square
Structure Width (in):
134
Structure Height (in):
45
Mean Roof Height (ft):
40
Building Dimension Parallel to
Wind (ft):
100
Building Dimension Normal to
Wind (ft):
289
FL
Loterol Force
Kd=
0.90
qz (Ib/ft2)=
62.15
A,(ft2)=
41.88
Lateral (GCf)=
1.90
Pressure (lb/ft)=
70.85
Uplift Force
•ed= i
qZ 0� , •
VerticaM(� 4=, •
Pressure (WD412+_
•
• 0906
S2.1s
•
41.88
•999�3 �
•
•
DIGITAL SEAL
NOTES: Design rs in accordance with ASCE 7-10(ASD method) and the Florida Building Cade Sixth Edition . Results are not valid for use unless �\\ a6d.0al lith Raised Engineer S
approved via original signature and raised engineer seal of a PE from Engineering Eapress. Selection & installation of products shall be approved
sing these dimensions and pressures as verified by others. \ \ - ' L,
\ FN ! 8/1/2019 ~
Ergials I Bennardo, P.E.
a ��� PE46549
Note: For openings to be properly rated in Zone a, no part of the opening shall be within — ;V (lQ� r, v 9885
v1.13 160 SW 12TH AVENUE, SUITE 106, DEERFIELD BEACH, FLORIDA-8
PHONE: (954) 354-0660 - (866) 396-9999r_ _11 '
ENGINEERINGEXPRESS.COM
•,R7pA ��-
�,,7tiy� E N GIN
0 1 l l l l 1 0