Loading...
RC-18-2036 (3)Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: Location Address Parcel Number 1158 NE 99 ST, Miami Shores, FL 33138 1132050180130 Contacts Permit NO.: RC-7-18-2036 Permit Type: Building (Residential) Work Classification: Addition/Alteration Permit Status: Approved .9 F Expiration:07/17/2019 SUSAN PINNAS Owner SUSAN PINNAS Applicant 1158 NE 99 ST, MIAMI SHORES, FL 331382641 1158 NE 99 ST, MIAMI SHORES, FL 331382641 HOME OWNER Contractor PRIMUS CONSTRUCTION SERVICES INC Contractor HOME OWNER RAFIU ABIODUN JINADU 16536 NW 22 ST, PEMBROKE PINES, FL 33028 Business: 9548172132 Other:9548172132 Description: BEDROOM ADDITION, KITCHEN & BATHROOM Valuation: $ 91,200.00 Inspection Requests: ALTERATION. 305-762-4949 Total Sq Feet: 695.00 Fees Amount CCF $55.20 DBPR Fee $41.04 DCA Fee $27.36 Education Surcharge $18.40 Notary Fee $5.00 P&Z Review Fee $35.00 Permit Fee $2,536.00 Residential Application Fee $200.00 Scanning Fee $30.00 Structural Review ($90) $90.00 Structural Review ($90) $90.00 Technology Fee $68.40 Total: $3,196.40 Payments Date Paid Amt Paid Total Fees $3,196.40 Deposit 01/14/2019 $200.00 Check # 1019 01/18/2019 $2,996.40 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor "/ Agent Date January 18, 2019 Page 2 of 2 Primus Construction Services, Inc. PGeneral Contractor � Raf Jinadu, M.Sc. P O. Box 822826 954-817 2132 h ibroKe P:nes. FI 33082 954 704-Y 141 primusconstruct:on 1(i )gmai, corn aJJ_y26-li -c c-,m •,... �Zr2\1111-2 'v BUILDING PERMIT APPLICATION Miami Shores Village Fp, r C 1FT V K L Building Department 31 2018 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 LBY Tel: (305) 795-2204 Fax: (305) 756-8972 / -7 INSPECTION LINE PHONE NUMBER: (305) 762-4949 l FBC 20 Master Permit No. - (� 2,U 3 (o Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL PLUMBING . VIECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1158 NE 99TH STREET ' city: Miami Shores County: Miami Dade Zip: i�3) Folio/Parcel#: 11-3205-018-0130 Is the Building Historically Designated: Yes NO X �11 Occupancy Type: R3 Load: Construction Type: VB Flood Zone: X BFE: 4 FFE: OWNER: Name (Fee Simple Titleholder): SUSSAN PINNAS Phone#: 305-987-1335 ,,,,,,.,, 1158 NE 99TH STREET City: MIAMI-SHORES State: FLA Zip: 33138 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: PRIMUS CONSTRUCTION SERVICES, INC Phone#: 9,54-817-2132 Address: 16536 NW 22ND STR. City. PEMBROKE-PINES State: FLA. Zip: 33028 Qualifier Name: RAFIU A. JINADU Phone#: 954-817-2132 State Certification or Registration #;. Certificate of Competency #: CGC 1507774 DESIGNER: Architect/Engineer: CARLOS ROLLE Phone#: 786-251-9289 Address:12491 SW 134TH CT. City: MIAMI State: FL Zip: 33186 Value of Work for this Permit: $ i4e-,eee—cr 1 7­0'�4- '*To Square/Linear Footage of Work: 695 Type of Work: 0 Addition 0 Alteration New ❑Repair/Replace Description of Work: BEDROOM ADDITION, KITCHEN & BATHROOM ALTERATION ❑ Demolition Specify color ��of,,--color thru file: _ Submittal Fee $-(N Permit Fee $ 2J 3G CCF $ CO/CC $ 1'J b- Scanning Fee $ 30, 01 _ Radon Fee $ 2 DBPR $ L (' O Notary $ S r Technology Fee $ (0 l ' 0 Training/Education Fee $ �� Double Feee$$�r-, Structural Reviews $ o . 4D ci6 . co Bond $ 5W ` 00 -35 , coV TOTAL FEE NOW DUE $ 2/ 0)CIGo • (7In (Revised02/24/2014) I. .. . .c , Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. CSignature') Zci OWNER or AGENT The foregoing instrument was acknowledged before me this aS day of ^U p,�Q 20 18 by <- F P who is personally known to me or who has produced fir( DCZ as identification and who did take an oath. Signature �4�r CONTRACTOR The foregoing instrument was acknowledged before �me this /3 day of c-c 20 Iiby IZS"L% &6;Jc4r% Si who is personally known to me or who has produced r � v-c.rf L; c-t.rt,yL as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: XC rG_rX 'Co�1un Seal: o40 PuV Y Notary Public State of Florida Seal:.. r Sindia Alvarez FF 156750 1p * * K RL.DIE CKW Comma mIGG187980 Epirm FebnlBryZp, a MY Commission ?dl 2022 +�`oftio� Expires0910312018 6ond�d?IruBut* lServkh ********�*��*#1i�****���##•i��i#*��**�*�1k�#*�*�fi**1i***iR�***�i�*****��**�1k** *�#fi*ii3***#�*�i\*1i**�i*i�1i**fi*i�******� APPROVED BY Plans Examiner a Zoning (1 Structural Review (Revised02/24/2014) Clerk Property Search Application - Miami -Dade County Page 1 of 1 t- in �` OFFICE OF THE PROPERTY APPRAISER 16 1`1 Summary Report Property Information Folio: 11-3205-018-0130 Property Address: 1158 NE 99 ST Miami Shores, FL 33138-2641 Owner SUSAN PINNAS Mailing Address 1158 NE 99 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/1/0 Floors 1 Living Units 1 Actual Area 2,003 Sq.Ft Living Area 1,531 Sq.Ft Adjusted Area 1,748 Sq.Ft Lot Size 10,400 Sq.Ft Year Built 1947 Assessment Information Year 2018 2017 2016 Land Value $374,393 $374,393 $348,089 Building Value $131,100 $121,661 $121,661 XF Value $0 $0 $0 Market Value $505,493 $496,054 $469,750 Assessed Value $505,4931 $198,3191 $194,240 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $297,735 $275,510 Homestead Exemption $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 Widow Exemption $500 $500 .._....... ..._._,_.. Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). (Short Legal Description REV PL MIAMI SHORES SEC 8 PB 43-69 LOT 4 BLK 179 LOT SIZE IRREGULAR OR 15721-2050 1192 4 Generated On : 7/25/2018 Taxable Value Information 2018 2017 2016 _...._ County Exemption Value $0 $50,500 $50,500 Taxable Value $505,493 $147,819 $143,740 School Board Exemption Value $0 $25,500 $25,500 ..____ Taxable Value j $505,493 __a__._ ._ $172,819 $168,740 City Exemption Value $0 $50,500 $50,500 Taxable Value $505,493 $147,819 $143,740 ..._.____.. _ ._........ ........_.__._....... Regional Exemption Value $0 $50,500 $50,500 Taxable Value $505,493 $147,819 $143,740 Sales Information Previous OR Book - Price: Qualification Description Sale Pa 9a 30880- 02/05/2018 $540,000 Qua[ by exam of deed 1923 15721- Sales which are disqualified as a result 11/01/1992 $0 2050 of examination of the deed The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: https://www.miamidade.gov/propertysearch/ 7/25/2018 SUSAN KNAPP PINNAS DURABLE GENERAL POWER OF ATTORNEY I, SUSAN KNAPP PINNAS, of Miami -Dade County, Florida, hereby appoint NAT PINNAR and S. CLARK KNAPP, JR., jointly, as my true and lawful attorney -in -fact (hereinafter, my "Agent"), for me and in my name, place and stead, to act for me and in my name and on my behalf to exercise the powers set forth under this instrument. Except as otherwise provided in the Florida Power of Attorney Act, my Agent may exercise these powers independently and without the approval of any court. My Agent, however, shall exercise all powers in a fiduciary capacity in good faith, as a prudent person would using reasonable care, skill and caution. My Agent shall have the following powers: (1) To conduct investment transactions as provided ins. 709.2208(2), Florida Statutes; and (2) To buy, purchase, transfer, convert, endorse, sell, assign, set over and deliver any and all shares of stock, bonds, mutual funds, debentures, notes, subscription warrants, stock purchase warrants, evidences of indebtedness, or other securities now or hereafter standing in my. name or owned by me and to make, execute and deliver any and all written instruments of assignment and transfer necessary or proper to effectuate the authority hereby conferred; and (3) To ask, demand, sue for, collect and receive all sums of money, dividends, interest, payments on accounts of debts and legacies and all property now due or which may hereafter become due and owing to me, and give good and valid receipts and discharges for such payment; to buy and sell securities of all kinds in my name and for my account and at such prices as such Agent, in the exercise of absolute discretion, shall deem appropriate; and (4) To vote any corporate securities for any purpose; -to exercise or sell any subscription or conversion rights; to consent to and join in or oppose any voting trusts, reorganizations, consolidations, mergers, foreclosures and liquidations and in connection therewith to deposit securities and accept and hold other securities or property received therefor; and (5) To manage any and all property, real or personal,. tangible or intangible, wherever situated, including homestead property, to sell, convey, assign, mortgage, encumber or otherwise transfer the same; to lease same; to L- I a foreclose mortgages or enforce any other rights with respect to the same; to take title to the same in my name; and to execute, acknowledge and deliver deeds, bills of sale, mortgages, releases, satisfactions and any other instruments relating to the same which my Agent, in the exercise of absolute discretion, shall deem appropriate; and (6) To conduct banking transactions as provided in s. 709.2208(1), Florida Statutes; and (7) To do business with banks. and brokers, and particularly to endorse all checks and drafts made payable to my order and collect the proceeds and to sign in my name checks on all accounts standing in my name, and to withdraw funds from said accounts, to open accounts in my name or in the name of my Agent, as my attorney -in -fact; and (8) To borrow money from any lender, personal or corporate, and to extend or renew any existing indebtedness of mine; and (9) To have access to any safe deposit box to which I have access; and (10) To compromise, contest, prosecute or abandon claims in favor of or against me; and (11) To make such ayments and expenditures as my Agent shall, in the exercise of a olute discretion, determine to be appropriate in connection with any of e foregoing matters or with the administration of my affairs; and (12) INITIAL To manage any .Individual Retirement Account ( or other retirement plan assets held in my name, including to open retirement accounts in my name, to make contributions to a retirement plan, to sell and reinvest retirement plan assets and to exercise investment powers with respect to a retirement plan, to select the form and timing of payments under a retirement plan and to make beneficiary distributions or withdrawals from such plan, to make a rollover, including a direct t stee-to-trustee transfer of assets from one retirement plan to another, d t/de with tax liability matters with respect to retirement plan ass ts; an (13) INITIAL6 To make, sign and verify income, gift or other tax returns and tax filings, including to make relevant tax elections, to prepare and file extension requests or amendments, and to enter into settlement agreements, and to represent me in all tax matters before any office of the Internal Revenue Service or any other taxing authority, within the limitations of the applicable law; and -2- (14) INITIAL () To make gifts of any and all of my property, real or pe s nal, tangible or intangible, wherever situated, which my Agent, in the exercise of absolute discretion, shall deem appropriate, to any individual or entity, including my Agent; provided, however, that gifts during any calendar year to any donee in amounts which cumulatively exceed the annual exclusion amount for Federal Gift Tax purposes provided in Section 2503 of the Internal Revenue Code of 1986, as amended to the date of the gift, must be approved in writing in advance by a majority of my children who are sui juris at the time of the gift; and provided further, that any gift made to or for the benefit of my Agent in excess of the annual exclusion amount shall be made in a fiduciary capacity and only for such Agent's health, education, support or maintenance and not to satisfy any legal obligation of the Agent; and (15) To take care of, contract for, make arrangements for and make financial commitments for, on my behalf, the medical care and attention of myself, including, without limiting the foregoing, to engage doctors and nurses, to provide hospitalization, consent to operations, call ambulances and provide any required consents to medication and any other medical procedures, provided, however, if at any time a Health Care Surrogate is acting on my behalf, my Agent shall cooperate with, follow the directives of and (using my property) provide any necessary financial assistance to such Health Care Surrogate and I hereby designate my Agent as a "personal representative" of mine for health care information and authorize the release of all medical and other information relating to my health and healthcare, including all my "individually identifiable health information" and any "protected health information" (as those terms are defined in the regulations under HIPAA at 45 CFR § 160.103), to my Agent so that my agent can make informed decisions regarding my care; and (16) To access, obtain, control, use, establish, modify, cancel, delete, continue, surrender, transfer, distribute, dispose of or otherwise administer all my digital assets and digital accounts and all my digital devices, wherever held and whether held in my name alone or held jointly. My Agent is specifically authorized to access, request, delete, create and change my access credentials to any of my digital assets and digital accounts and my digital devices, such as username, password, and secret questions. The term "digital assets and digital accounts" includes, but is not limited to, e- mail accounts, social media accounts, blogs, accounts with Internet service providers, accounts to manage websites and website domain names, web hosting accounts, online accounts, bank accounts, investment accounts, accounts with health care providers, gaming accounts, accounts with -3- publishers, accounts for access to employee benefits, accounts with retail vendors, accounts with utility companies, file sharing accounts, software licenses, tax preparation service accounts, virtual property, other virtual or online programs, including frequent -flier or other bonus programs, and any other personal or intellectual property held or otherwise stored in electronic or digital format, including any similar electronic or digital items that currently exist or may exist in the future as technology develops, and all data and content within all such accounts, e-mails, images, audio, documents, messages, video, and similar digital files which currently exist or may exist as technology develops, wherever located regardless of the ownership of the physical device upon which stored. The term "digital devices" includes, but is not limited to, desktop and laptop computers, tablets, peripherals, mobile telephones, smartphones, websites, hard drives, jump drives, flash drives, portable drives, social -media outlets, public or private servers, cloud -based servers and any similar digital device which currently exists or may exist in the future as technology develops, whether or not such device is owned or leased. I authorize any person or entity that possesses, has custody, or controls any online accounts or electronically stored information of mine to divulge to my Agent any such information, the contents of any communication that is in electronic storage and any records pertaining to me that are maintained by that person or entity. The foregoing authorizations are to be construed as my lawful consent to all such access or disclosure under the Florida Fiduciary Access to Digital Assets Act, as set forth. in chapter 740, Florida Statutes, the Electronic Communications Privacy Act of 1986 (including the Stored Communications Act thereunder), the Computer Fraud and Abuse Act of 1986, and any other applicable federal or state data privacy law or criminal law, and my Agent shall not be liable or be considered to have violated applicable laws for acting under such specific authorization; and (17) To transfer assets to the then acting Trustee of the revocable trust under the Susan Knapp Pinnas Declaration of Trust executed by me, of even date herewith, with myself as Settlor and Trustee, as the same may be amended to and including the date of my death, to be held and administered as provided therein. With respect to the foregoing, I give and grant to my Agent full power and authority to do and perform all and every act and thing whatsoever requisite and necessary to be done in and about the premises as fully, to all intents and purposes, as I might or could do if personally present, hereby ratifying and confirming all that my Agent shall lawfully do or cause to be done under this instrument. I -4- a I recognize that my Agent's actions taken pursuant to the specific grants of authority in this instrument could involve my Agent in conflicts of interest (created either by me or by my Agent). Provided that my Agent acts in good faith, I waive any express duty of loyalty imposed under Section 709.2114(2), Florida Statutes. My Agent shall be entitled to reasonable compensation and reimbursement for all expenses reasonably incurred by my Agent on my behalf. No Agent may participate in an action to the extent that a payment or distribution pursuant to that action would discharge a legal support obligation of that Agent. No Agent who is the insured of any insurance policy that I own may exercise any rights or have any incidents of ownership with respect to that policy, including the power to change the beneficiary, to surrender or cancel the policy, to assign the policy, to revoke any assignment, to pledge the policy for a loan, or to obtain from the insurer a loan against the surrender value of the policy. All such power is to be exercised solely by another Agent, if any. If NAT PINNAR or S. CLARK KNAPP, JR. resigns, dies, becomes incapacitated, is not qualified to serve, or declines to serve, I hereby appoint the one not unable to act as my successor Agent hereunder. All successor Agents shall have the rights, powers, privileges and discretions specified under this instrument. Any third party to whom this power of attorney is presented may conclusively rely upon an affidavit by my Agent, stating, to the best of my Agent's knowledge and belief, that this power has not been revoked, that I am then living, and that no proceedings have been initiated to determine my incapacity. No third party relying on this power and that affidavit will be liable for any losses, damages, or claims caused by compliance with the action requested by my Agent, unless that third party has actual knowledge of my death or the revocation of this power. A third party who improperly refuses to accept this power of attorney will be liable for damages, including reasonable attorney's fees and costs, incurred in any action or proceeding that confirms the validity of this power of attorney. As provided in Section 709.2106, Florida Statutes, a photocopy or electronic copy of this power is sufficient for its exercise. -5- This Durable Power of Attorney is not affected by subsequent incapacity of the principal except as provided in Chapter 709, Florida Statutes. IN WITNESS WHEREOF, I have hereunto signed my name this i2 day of STATE OF FLORIDA ) ) SS: COUNTY OF MIAMI-DADE ) On this 12 day of J u l/ , 2018, before me personally came SUSAN KNAPP PINNAS, who is personally known to me (yes) (no) or who has produced — N�- as identification, and who acknowI ged a cution of the f egoing instrument. n t Publi , State of Flor' a N e: MC11 e•Ch (Print me) y Commission Expires: mAplanning\n-r\pinnas\ep documents 2018\adv - dpoa susan 2018.docx NEIL R. CHRYSTAL by Notary Rubllc - State of Florida + + •= Commisslon #. FF 199745 '••,; Y, ��� My Comm. Expires Feb 15.2019 -6- "1 '•• Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: /,COPY A. OF QUALIFIER'S STATE LICENCES B. Z COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE* D. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. D. COPY OF LIABILITY INSURACE* E. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Certificate must specify the description of operations or contractor license number. ..........................................................................�0 E E N 0 0 ......... ■ BUSINESS NAME: MI MUD G�I�1�1"2.UGr �,��� r 1 IG BUSINESS ADDRESS:140T" P Wvk,/ '1.SOJI 2 CITY W(OI-KE STATE` ZIP --)'30 &'b l BUSINESS PHONE: (�� ) DI1'' 2I�2 FAX NUMBER ( ) CELL PHONE (Vf) 01 , 2 W QUALIFIER'S NAME: RAF W JV'IA12y QUALIFIER'S LIC NUMBER: 6616 9D 1 % -7 4 RICK SCOTT, GOVERNOR JONATHAN ZACHEM, SECRETARY bIjdF'pr- STATE OF FLORIDA DEPARTMENT OF BUSINESS ►IV -RI. FESSIONAL REGULATION CONSTR THE GENERA PROVIS! " LI'C �I S.L.NG BOARD FN'I CLm,dIFLEDkUNDER THE ;` E1 "4` 89 �FC'O FL 33,020fi LItiMSMN.UM,r`1�5077,�74 �AII�RgFgYSYY�I�I�� EXPIRATIOIkD G15T 31, 2020 Always verify licenses online at MyFloridal-icense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. RAFIU A. JINADU 16536 NW 22 ST PEMBROKE PINES FL 33028 CITY OF PEMBROKE PINES 601 CITY CENTER WAY, LBTR-4TH FLOOR PEMBROKE PINES, FL 33025 LOCAL BUSINESS TAX RECEIPT ACCOUNT -NO: 20110867/01 RECEIPT -YEAR: OCTOBER 1, 2018 thru SEPTEMBER 30, 2019 RECEIPT -NO: 180037 jj����j; NOTICE I®I®WIUI0�Ujjjjj 1m10 BUS -NAME PRIMUS CONSTRUCTION SERVICES INC In the event the business to which.this BUS-ADDR 16536 Nil 22 ST receipt was issued changes hands, the receipt PEMBROKE PINES FL 33028 will become null and void. An application for -a new receipt must be made._ BUS-DESCR GENERAL CONTRACTOR RECEIPT -TYPE: RESTRICTED LICENSE BUSINESS -CLASSIFICATION INV/UNITS EFFECTIVE PERMIT-NUMBER/COMMENTS RCT TYPE CGC. CONTRACTOR - GENERAL 0 10/01/2018 P/Pines STATE OF FLORMA COUNTY OF BROWARD CONTRACTOR AFFIDAVIT A? . RECEIVED JAN 14 yppjC' The undersigned contractor, Primus Co traction Services, Inc., 16536 NW 22 Street. Pembroke Pines, FlaJ3Q2.8, under a certain contract with Ms. S Pinna, dated January 8, 2019, in connection with the building addition and renovation work at location: It 58 NE Street, Miami Shores, Florida does hereby acknowledge that the cost estimates submitted to Village of Miami Shores, under process number, RC-2036 are accurate and true. PRIMUS CONSTRUCTION SERVICES, INC. By: RAFIU JINADU Title PRESIDENT STATE OF ��Cczi�A COUNTY OF W t -cD . . .... ...... ...... . ...... .... . ..... ...... .... ..... .. .. .... ...... . . . . ...... Before me, the undersigned Notary Public, personally appeared 4a16U known to me to be the of 4'�Ut4ol co►.�s-lszi�C'T,cn.;�t�f �C and on behalf of said contractor, for the uses and purposes therein expressed. IN WITNESS WHEREOF, I have hereunto set my hand and official notarial seal at !PoR'i 1=1— . - , this the l-08 day of 201`_ Sandra B Lugo •^ �, a��� ���° = Commission J GG150926 NOTARY PUBLIC Expires: October 24, 2021 (SEAL) Bonded thru Aaron Notary My Commission expires: w�) IAL+ /&C- 1 cto zo;)G PRIMUS CONSTRUCTION SERVICES, INC. 16536 N.W. 22ND STREET, PEMBROKE PINES, FL 33028 PHONE (954) 704-9354 • CELL (954) 817-2132 • E-MAIL ABBE 2640101-CON1 Building Official Village of Miami Shores Building Department Miami Shores, Florida Re: Permit Number: RC-7-18-2036 _ Explanation for Reduced Cost from 12-27-18 Estimate Dear Naranjo Ismael:- Our decision to reduce price on labor and some of the aspects of the originally submitted cost was based on re- structuring mobilization to each activity to help our client This was done after considered rational analysis. Please call or email me if there is any question. ' • • Sincerely, • eid ...... .... P, S. • Project Manager. • • • • • • • • . ... . . • ••. Rrjih& Codstrbction Services, Inc. 16SS;-NW R2;d StreeY,-Pe mbroke Pines, FI 33028 SUSAN AND CLARK PINNAS BUNDING ADDITJON PROJECT 1158 NE 99 STREET MIAMI SHORES, FLORIOA fa�u -see -T— a era s - Description Unit Quantity Cost/Equipment s/Cost Total Profit and overhead : LS •' :'. Z" • $ 10,000.00 $ 10,000.00 CONSTRUCTION Demo/clearing LS f•• $ 2,500.00 $ 2,500.00 Survey and testings LS 1 $ 3,000.00 $ 3,000.00 Foundation (digging/forms)/fill LS 1 $ 2,000.00 $ 2,000.00 $ 4,000.00 Concrete works (fdtion, slab, tie beam, cell fill) rebar and mesh included LS 1 $ 7,000.00 $ 6,000.00 $ 13,000.00 Masonry LS 1 $ 4,800.00 $ 40800.00 Windows/doors LS 1 $ 9,000.00 $ 3,000.00 $ 12,000.00 Electrical/Wiring/Fixtures LS 1 $ 6,000.00 $ 6,000.00 $ 12,000.00 Mechanical (HVAC) Equipment/duct LS 1 $ 5,000.00 $ 3,500.00 $ 8,SOOAO Roofing LS 1 $ 7,200.00 $ 7,200.00 Trusses/sheathing/facial LS 1 $ 10,000.00 $ 5,400.00 $ 15,400.00 Plumbing LS 1 $ 4,000.00 $ 6,000.00 $ 10,000.00 INTERIOR Interior Framing LS 1 $ 3,000.00 $ 4,000.00 $ 7,000.00 Interior Drywall LS 1 $ 3,200.00 $ 6,200.00 $ 9,400.00 Tiling/base board LS 1 $ 3,800.00 $ 3,100.00 $ 6,900.00 Plumbing fixtures Owner's Allowance LS 1 $ 1,200.00 $ - $ 1,200.00 Kitchen cabinet and vanities LS 1 $ 7,000.00 $ 2,000.00 $ 9,000.00 Painting: Interior & exterior LS 1 $ 1,200.00 $ 2,400.00 $ 3,600.00 Appiicances: $ Dishwasher/washer & dryer LS 1 $ 2,500.00 $ - $ 2,500.00 Fridge LS 1 $ 1,000.00 $ - $ 1,000.00 DISPOSAL Dumpster (3 times) LS 1 $ 2,100.00 $ - $ 2,100.00 $ 145,100.00 Owner w Contractor Signature: ` Primus Construction Services, Inc. 16536 NW 22nd Street, Pembroke Pines, FI 33028 SUSAN AND CLARK PINNAS BUILDING ADDITION PROJECT ' 1158 NE 99 STREET MIAMI SHORES, FLORIDA ...:.. Description Unit Quantity atena s Cost/Equipment a or su - contractors/Cost .... Total •••• Profit and overhead LS 1 $ 10,000.00 $ 10,000400 CONSTRUCTION 0 "' Demo/clearing LS 1 $ 2,500.00 $ 2,500.Q0 Survey and testings LS 1 $ 3,000.00 $ 2,000.00 $ 3,000.00 $ 4,000.00 Foundation (digging/forms)/fill LS LS 1 1 $ 2,000.00 Concrete works (fdtion, slab, tie beam, cell fill) rebar and mesh included $ 7,000.00 $ 6,000.00 $ 13,000.00 Masonry LS 1 $ 4,800.00 $ 4,800.00 Windows/doors LS 1 $ 9,000.00 $ 6,000.00 $ 5,000.00 $ 3,000.00 $ 6,000.00 $ 12,000.00 Electrical/Wiring/Fixtures LS 1 $ 12,000.00 Mechanical (HVAC) Equipment/duct LS LS 1 $ 3,500.00 $ 8,500.00 Roofing 1 $ 7,200.00 $ 7,200.00 Trusses/sheathing/facial Plumbing LS 1 $ 10,000.00 $ 5,400.00 $ 15,400.00 LS 1 $ 4,000.00 $ 6,000.00 $ 10,000.00 INTERIOR $ 4,000.00 $ 6,200.00 Interior Framing LS 1 $ 3,000.00 $ 3,200.00 $ 7,000.00 $ 9,400.00 Interior Drywall LS 1 Tiling/base board LS LS 1 $ 3,800.00 $ 3,100.00 $ 6,900.00 Plumbing fixtures Owner's Allowance 1 $ 1,200.00 $ - $ 1,200.00 Kitchen cabinet and vanities LS 1 $ 7,000.00 $ 2,000.00 $ 9,000.00 Painting: interior & exterior Appl icances: LS 1 $ 1,200.00 $ 2,400.00 $ 3,600.00 $ - Dishwasher/washer & dryer LS 1 $ 2,500.00 $ - $ 2,500.00 Fridge LS 1 $ 1,000.00 $ - $ 1,000.00 DISPOSAL Dumpster (3 times) LS 1 $ 2,100.00 $ - $ 2,100.00 $ 145,100.00 c3Y9 Primus Construction Services, Inc. 16536 NW 22nd Street, Pembroke Pines, FI 33028 SUSAN AND CLARK PINNAS BUILDING ADDITION PROJECT 1158 NE 99 STREET MIAMI SHORES, FLORIDA atena s Description Unit Quantity Cost/Equipment too:** """ •..• TotaL..... a or su - contractors/Cost Profit and overhead LS 1 $ 10,000.00 $ 10,�QQ�Q4 _ CONSTRUCTION Demo/clearing • $ 2,$00.00 LS 1 1 $ 2,500.00 Survey and testings LS $ 3,000.00 $ 3,000.00 $ 4,000.00 Foundation (digging/forms)/fill LS 1 1 1 $ 2,000.00 $ 7,000.00 $ 2,000.00 $ 6,000.00 Concrete works (fdtion, slab, tie beam, cell fill) rebar and mesh included LS LS $ 13,000.00 Masonry Windows/doors $ 4,800.00 $ 3,000.00 $ 4,800.00 $ 12,000.00 $ 12,000.00 LS 1 1 $ 9,000.00 Electrical/Wiring/Fixtures LS $ 6,000.00 $ 6,000.00 Mechanical (HVAC) Equipment/duct LS 1 $ 5,000.00 $ 3,500.00 $ 8,500.00 Roofing LS LS 1 $ 7,200.00 $ 7,200.00 $ 15,400.00 Trusses/sheathing/facial _ 1 $ 10,000.00 $ 5,400.00 Plumbing LS 1 $ 4,000.00 $ 6,000.00 $ 10,000.00 INTERIOR Interior Framing LS 1 $ 3,000.00 $ 4,000.00 $ 7,000.00 Interior Drywall LS LS 1 $ 3,200.00 $ 6,200.00 $ _ 9,400.00 $ 6,900.00 Tiling/base board 1 1 1 $ 3,800.00 $ 1,200.00 $ 7,000.00 $ 3,100.00 $ - $ 2,000.00 Plumbing fixtures Owner's Allowance LS LS $ 1,200.00 Kitchen cabinet and vanities $ 9,000.00 Painting: interior & exterior LS 1 $ 1,200.00 $ 2,400.00 $ 3,600.00 Applicances: $ - Dishwasher/washer & dryer LS 1 $ 2,500.00 $ - $ 2,500.00 $ 1,000.00 Fridge LS LS 1 1 $ 1,000.00 $ 2,100.00 $ - $ - DISPOSAL $ 2,100.00 $ 145,100.00 Dumpster (3 times) **too* • • •• lie s..• . •• f...• .. 690000 . • • f • 1111.• i • .. • • a..,.. •e s . . • • Primus Construction Services, Inc. 16536 NW 22nd Street, Pembroke Pines, FI 33028 SUSAN AND CLARK PINNAS BUILDING 1158 NE 99 STREET MIAMI SHORES, FLORIDA ADDITION_ PROJECT T- Description Unit I Quantity a ena s Cost/Equipment a or su - contractors/Cost Total Profit and overhead LS _ LS 1 $ 10,000.00 $ 10,000.00 Demo/clearing 1 $ r 1 3,000.00 $ 3,000.00 Survey and testings LS $ $ 4,000.00 3,500.00 $ $ 4,000.00 7,000.00 Foundation (digging/forms) Concrete works (foundation, slab, tie beam, cell fill) LS 1 $ 3,500.00 LS 1 $ 7,000.00 $ 10,000.00 $ 17,000.00 Masonry LS LS _ LS 1 1 $ 12,000.00 $ $ 6,800.00 3,000.00 $ $ 6,800.ppi 15,000.00i _ Windows/doors Trusses/sheathing/facial 1 1 $ $ 12,000.00 3,000.00 $ 5,400.00 $ 17,40(1.00• Interior Framing LS $ 4,000.00 $ 7,000.9 Drywall LS LS 1 1 $ $ 3,200.00 4,000.00 $ $ 6,200.00 6,000.00 $ $ 9,40&99• 10,00azoi Plumbing Electrical/Wiring/Fixtures Mechanical (HVAC) Equipment/duct LS LS 1 1 $ $ 6,000.00 5,000.00 $ $ 6,000.00 3,500.00 $ $ 12,00 00'- 8,500.00 Roofing Painting: interior & exterior LS 1 $ 7,200.00 $ 7,200.00 LS LS 1 1 $ 1,200.00 $ 2,400.00 $ 3,600.00 Dumpster (3 times) $ 2,100.00 $ - $ 2,100.00 Flooring and cove (base board): owner chooses to do these with another contractor. No cost given. $ 1,200.00 Plumbing fixtures Owner's Allowance LS 1 $ - $ 1,200.00 Applicances: LS 1 $ 2,500.00 $ $ - - $ $ $ $ - 2,500.00 1,000.00 144,700.00 Dishwasher/washer & dryer: Owner's Allowance Fridge: Owner's Allowance LS 1 $ 1,000.00 DECIF v `--j� I 4 018 i i i i i• i / 9 li • 1 t • L i•i iii I • li ii ii i•i•i i a i 4 - .. i • i K- ii.•.. •. i•i♦ •J .? . i ESN R- Miami Shores Village Building Department 10050 NE 2nd Ave. ,,,� Miami Shores, FL 33138 305-795-2204 / Fax 305-756-8972 NOTICE TO MIAMI SHORES BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL 1W INSPECTOR UNDER THE FLORIDA BUILDING CODE. I (We) have been retained by to perform special inspector services under the Florida Building Code 6+h Edition (2017) and Miami Dade County Administrative Code at the project on the below listed structure as of (date). I am a registered • architect/professional engineer licensed in the State of Florida. Process Number: Q/j A^ '2 P,�� LApecial Inspector for Reinforced Masonry, Section 2122.4 of the FBC 6th Edition (2017) — Miami Dade County Administrative Code, Article II Section B-22 Special Inspector for — Trusses > 35 ft. long or 6 ft. high — S I Framing and Connections welded or bolted ' — Soil Compaction ...... • • Precast Attachments • Roofing Applications, Lt. Weight. Insul.Conc. "" — Other Note: Only the marked boxes apply. •""' ' The following individual(s) employed by this firm or me is authorized representative to jierform ...... inspection* 0 . * 0 2. •• . . ee 3. 4. *Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a professional engineer or architect: graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination; or registration as building inspector or general contractor. I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel performing inspection services. I (we), understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site for reference by the Miami Shores Building Department Inspector. All mandatory inspections, as required by the Florida Building Code, must be performed by the Miami Shores Building Department .Inspections performed by the Special Inspector hired by the owner are in addition to the mandatory inspections performed by the department. Further, upon completion of work under each Building Permit, I will submit to the Building Inspector at the time of the final inspection the completed inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and professional judgment those portions of the project outlined above meet the intent of the Florida Building Code and are in substantial accordance with the approval plans. Signed and Sealed Date: I U - r16— 18 Engineer/Al Name Cif bt '>, goLLkL({FC. Print Address I$v I N'vJ 196 M QI 1— M1AMt)t-L 33076 RC� Ph: 305-229-3874 Email : restructure@aol.com October 22, 2018. ROGER CHAVARRIA. P.E Consulting Engineer & Planner. 780 Tamiami Canal Rd. Miami, FL.33144 STRUCTURAL CALCULATION Project name: Addition to Susan Pinnas Residence at 1158 N.E. 99th. ST. Miami Shores, FL.33138 CONTEND: 1- Wall footing WF-16 2- Masonry wall- bearing wall R,: ENGINEERING Roger Chavarria. P.E. FL.Lic. PE #50712 780 Tamiami Canal Rd. Miami,FL.33144 Project Title: Engineer: Project ID: Project Descr: Printed: 22 OCT 2018, 5:OOPNI Wall Footin FIe=QTROGRA-21ENERCA-1 g ENERCALC, INC.1%3.2017, BuiId:10.17.8.29, Ver.6.17.11.30 0.00e Description : WF-16 FOOTING AT 1158 N.E. 99th. ST. MIAMI SHORES.FL. Code References Calculations per Load Combinations Used: ASCE 7-10 General Information Material Properties Soil Design Values fc : Concrete 28 day strength = 3.0 ksi Allowable Soil Bearing = 2.0 ksf fy : Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No Ec : Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance (for Sliding) = 250.0 pcf Concrete Density = 150.0 pcf Soil/Concrete Friction Coeff. = 0.30 (p Values Flexure = 0.90 Shear = 0.750 Increases based on footing Depth Analysis Settings Reference Depth below Surface Allow. Pressure Increase per foot of depth - O.Oft 0.0 ksf Min Steel % Bending Reinf. = Min Allow % Temp Reinf. = 0.00180 when base footing is below = 0.0 ft Min. Overturning Safety Factor = 1.0: 1 Increases based on footing Width • •' •" Min. Sliding Safety Factor = 1.0 : 1 Allow. Pressure Increase per foot of width: •. • _ • • 0.0 ksf %0 .' AutoCalc Footing Weight as DL Yes when footing is wider than - . . ft Adjusted Allowable Bearing Pressure • _ • 2.0 ksf • Dimensions Reinforcigg.. . • • • • Footing Width = 1.33 ft Footing Thickness = 12.0 in Bars along X-Y)Vis• ..... Wall Thickness = 8.0 in Rebar Centerline to Edge of Concrete... # of Bars iW" Width • ; • • •: . 2.... Wall center offset at Bottom of footing = 3.0 in Reinforcj), G j3;r%ze = # 5 • , from center of footing = 0 in • • • • • • **goes • .... • e g X a m i f e' 2-YS•an. � Applied Loads D Lr P : Column Load = 0.680 0.340 OB : Overburden = 0.0 0.0 V-x = 0.0 0.0 M-zz = 0.0 0.0 Vx applied = 0.0 in above top of footing L S W E H 0.0 0.0 0.0 0.0 0.0 k 0.0 0.0 0.0 0.0 0.0 ksf 0.0 0.0 0.0 0.0 0.0 k 0.0 0.0 0.0 0.0 0.0 k-ft RU. ENGINEERING Project Title: Roger Chavama. P.E. Engineer: Project ID: FL,Lic. PE #50712 Project Descr: 780 Tamiami Canal Rd. Miami,FL.33144 Punted: 22 OCT 2018, 5:00PM Wall FootingFile=C:1PROGRA-21ENERCA-1 ENERCALC, INC.1983-2017, Build:10.17.8.29, Ver.6.17.11.30 KW-06003507 Licensee: RC ENGINEERING Description : WF-16 FOOTING AT 1158 N.E. 99th. ST. MIAMI SHORES.FL. DESIGN SUMMARY - . • Factor of Safety Item Applied Capacity Governing Load Combination PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift Utilization Ratio Item Applied Capacity Governing Load Combination PASS 0.4585 Soil Bearing 0.9169 ksf 2.0 ksf +D+Lr+H PASS 0.002824 Z Flexure (+X) 0.06613 k-ft 23.414 k-ft +1.20D+1.60Lr+0.50L+ PASS 0.002824 Z Flexure (-X) 0.06613 k-ft 23.414 k-ft +1.20D+1,60Lr+0.50L+ PASS n/a 1-way Shear (+X) 0.0 psi 82.158 psi n/a PASS 0.0 1-way Shear (-X) 0.0 psi 0.0 psi n/a Detailed Results • ...... ...... Soil Bearing • •.' . • • • Rotation Axis & Actual Soil Bearing $Jresss -Actual I AIIowN? • Load Combination... Gross Allowable Xecc -X • •tX 0 0 . Ratio i . • � ; +D+H 2.0 ksf 0.0 in 0.6613 ksf 0,U43iksf • • • • 0.33h • +D+L+H 2.0 ksf 0.0 in 0.6613 ksf 0$6'J Af • • • • 0.33h..... +D+Lr+H 2.0 ksf 0.0 in 0.9169 ksf 0.911F�9 lysf . . 0.45&• e • • +D+S+H 2.0 ksf 0.0 in 0.6613 ksf flFC7~3•ksf • • ; 0.33J , e 9 9 +D+0.750Lr+0,750L+H 2.0 ksf 0.0 in 0.8530 ksf s • • 615301csf 0.427 +D+0.750L+0.750S+H 2.0 ksf 0.0 in 0.6613 ksf .• 8.691�icf 0.331 • +D+0.60W+H 2.0 ksf 0.0 in 0.6613 ksf 4,661 kef 0.331""• +D+0.70E+H 2.0 ksf 0.0 in 0.6613 ksf aQ.6613 J sf . 0.331,,,,,: +D+0.750Lr+0.750L+0.450W+H 2.0 ksf 0.0 in 0.8530 ksf EM kf ::s0.42 • +D+0.750L+0.750S+0.450W+H 2.0 ksf 0.0 in 0.6613 ksf 0.03 ksf 0.331 +D+0.750L+0.750S+0.5250E+H 2.0 ksf 0.0 in 0.6613 ksf 0.6613 ksf 0.331 +0.60D+0.60W+0.60H 2.0 ksf 0.0 in 0.3968 ksf 0.3968 ksf 0.198 , +0.60D+0.70E+0.60H 2.0 ksf 0.0 in 0.3968 ksf 0.3968 ksf 0.198 Overturning Stability Units : k-ft Rotation Axis & Load Combination... Overturning Moment Resisting Moment Stability Ratio Status Footing Has NO Overturning Sliding Stability Force Application Axis Load Combination... Sliding Force Resisting Force Sliding SafetyRatio Status Footing Has NO Sliding Footine Flexure Flexure Axis & Load Combination Mu Which Tension @ Bot. As Req'd Gvrn. As Actual As Phi*Mn k-ft Side ? or Top ? in"2 in12 in12 k-ft Status +1.20D+1.60Lr+0.50L+1.60H 0.06613 -X Bottom 0.2592 Min Temp % 0.62 23,414 OK +1.20D+1.60Lr+0.50L+1.60H 0.06613 +X Bottom 0.2592 Min Temp % 0.62 23.414 OK One Way Shear Units : k Load Combination... Vu @ -X Vu @ +X Vu:Max Phi Vn Vu / Phi*Vn Status +1.20D+1.60Lr+0.50L+1.60H 0 osi 0 osi 0 osi 82.158 osi 0 OK 8" Masonry Wall Design v1.10 Code: ACI 530-13 Project Name: Addition for Susan Pinas Project Number: 1158 NE. 99 th. ST. Miami Shores FL. Design Element: Full Bearing Wall 10/22/2018 Data Input Height Of Masonry Wall = 10.00 ft F'm (with inspection) = 1500 psi Fs = 24000 psi Wall Thickness = 0.635 ft Use d = 3.81 in Select RM 5 48 Net Block Area, An = 40.7 inz/ft Ix, Moment of Inertia = 332.0 in r, Radius of gyration = 2.66 Em = 1350000 psi Es = 29 x 10a = 29000000 psi Modular Ratio n = 21 Use b = 48 in d = 3.81 in Bar Area = 0.31 in p=As/bd= 0.001695101 k=((np)^2+2np)".5-np = 0.24 j = 1-k/3 = 0.92 Fa = 0.25 F'm (1-(h / 140 r)"2) = 361.46 psi Allow Fb = 0.33•F'm = 495 psi Dead + 0.75 (Live + Lateral) = 0.6 Dead + lateral + uplift = Dead +live = 1016.0 126 Ib 0.0 480 ft-lb ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 30 Tamiami Canal Rd.. Miami, FL.33144 Ph = 305-229-3874 Dead 1 = 196 plf e = 0.00 in 0 ft-lb/ft Dead 2 = 480 pif e = 0.00 in 0 ft-Ib/ft Dead 3 = plif e = 0.00 in 0 ft-Ib/ft E DL = 676 E Meg = 0 ft-lb/ft Live 1 = 340 plf e = 0.00 in 0 ft-lb/ft Live 2= 0 plf e= 0.00 in O ft-lb/ft Live 3= 0 plf e= 0.00 in O ft-lb/ft E LL = 340 1 M, = 0 ft-lb/ft Wind uplift = -280 plf e= 0.00 in 0 ft-lb/ft Uniform Lateral Load = 38.4 psf (distances are from bottom) 480 ft-lb/ft Partial Uniform Lateral Load = 0 psf 0.00 ft. 0.00 ft. 0 ft-Ib/ft Concentrated lateral Load = 0 pIf 0.00 ft. 0 ft-lb/ft E ML,t = 480 ft-lb/ft Masonry Moduli F'm Ern Bar Size Bar Area 1500 1.35 e06 psi 4 0.20 2000 1.8 e06 psi 5 0.31 2500 2.25 e06 psi 6 0.44 3000 2.5 e06 psi 7 0.60 4000 2.9 e06 psi 8 0.79 5000 3.2 e06 psi 9 1.00 6000 3.5 e06 psi 10 1.27 Units Grouted Molar ♦ Cells Bedding 721 lb Ibs/ft Hollow none - 1 Face Shell 360 ft-lb ft-lbs/ft Hollow none - 2 Full 100% Solid nope - 3 •Full fa, Axial Stress 25.0 3.1 17.7 ps► • • sioaow• • • 8 ip os. • Full fb, bending stress 0.0 304.3 228.2 :psi • Hollow. •161h �. •Fpce Shell fs, Steel Stress 0 21172 15879 psi • • 4io�+„•,-,: �4t oz. Flats Shell Add'I steel stress to axial Tension 0 0 0 •WP • • %%pw • 32 M wt. "ce Shell Hollow 40 in o.c. Face Shell fa I Fa = 0.069 0.009 0.049 Hollow 48 in o.c. Face Shell fb ! Fb = 0.000 0.615 0.461 Hollow 56 in o.f,.• �ac�$lyell • 096 1,18119w • • &4 in o.c. iace 6hell talfa+}blfb = Q •,''0. 1E� Q Ir1ollow • V is o.i Face shell fs/Fs= 0000 • •• ; • • •• • • • ••• • • • • • • • • • • • • • •♦ •• • • • •• •- Section Properties A in2/ft I, In'/ft S. In3/ft r in 30.0 308.7 81.0 2.84 41.5 334.0 87.6 2.84 91.5 443.3 116.3 2.19 91.5 443.3 116.3 2.19 62.0 378.6 99.3 2.43 51.3 355.3 93.2 2.53 46.0 343.7 90.1 2.59 42.8 336.7 88.3 2.63 40.7 332.0 87.1 2.66 39.1 328.7 86.2 2.68 38.0 326.2 85.6 2.70 37.1 324.3 85.0 2.71 t RCt Ph:305-229-3874 Email: restructuregaol.com June 06, 2018. ROGER CHAVARRIA. P.E Consulting Engineer & Planner. 780 Tamiami Canal Rd. Miami, FL.33144 STRUCTURAL CALCULATIONS Project name: Addition to Susan Pinnas Residence at*:::::* 1158 N.E. 99t". ST. Miami Shores, FL.33138 ..... CONTEND: 1- Wind Load calculations, based on A.S.C.E. 7-10 as Uplift and Gravity loads for the Roof Trusses and Windows and Doors 2- NOA for the roof Trusses straps. .000 0 so • D r- rya Dat EN , RC. ENGINEERING Project Title: Roger Chavarria. P.E. Engineer: Project ID: FL.Lic. PE #50712 Project Descr: 780 Tamiami Canal Rd. Miami,FL.33144 Pdnted: 6 JUN 2018. 5:24PM �tASCE 7-10 Wind Forces Chpt 28, Pt2 & Chpt 30 Pt2 File =C:umuRCENG-1 E-1\ENERCA-1 ENERCALC. INC. 1983.2017, Bwld:10.17.&29, Vec6,17.11.30 Description : WIND PRESSURES FOR NEW WINDOWS AND DOORS AT 1158 N.E. 99 th.ST. MIAMI SHORES,FL33138 Analytical Values Calculations per ASCE 7-10 V : Basic Wind Speed per Sect 26.5-1 A, B or C 136.0 mph Roof Rise:Run Ratio 4:12 Occupancy per Table 1.5-1 11 All Buildings and other structures except those listed as Category I, III, and IV Exposure Category per 26.7 Exposure C 0 "' • " MRH : Mean Roof Height 12.0 ft " "";' Lambda : per Figure 28.6-1, Page 305 1.21 " ' *::go* ' . ; ' Effective Wind Area of Component & Cladding 17.0 fM2 "' ; " " ' • • • . • Roof pitch for cladding pressure 0 to 7 degrees """ ' : 0 0 • .: User specified minimum design pressure 10.0 psf . • • . . • : • Topographic Factor Kzt per 26.8 1.00 • 0 • • • 0 : 00 . LHD : Least Horizontal Dimension 18.0 ft 0 : • : : • • • • • a = max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH)) 3.00 ft max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*I�RH)7' ' """ • Design Wind Pressures ••••• . • Minimum Additional Load Case per g8.4.4.=� 6 PSFo n entire vertical pjw: • Horizontal Pressures ... """ Zone: A = 49.17 psf Zone: C = 32.79 psf ' 0 •' ; .. . : ""; Zone: B = 10.00 psf Zone: D = 10.00 psf ' ..' .' Vertical Pressures ... Zone: E _ -42.66 psf Zone: G = -29.72 psf Zone: F = -29.72 psf Zone: H = -22.53 psf Overhangs .. . Zone: Eoh = -59.80 psf Zone: Goh = A6.78 psf Component & Cladding Design Wind Pressures Design Wind Pressure = lambda ' Kzt * Ps30 per Eq 30.5-1 Roof Zone 1 : Positive: 15.655 psf Minimum Additional Load Case per 28.4.4 =16 PSF Negative: -39.613 psf on entire vertical plane Roof Zone 2 : Positive: 15.655 psf Negative: -62.632 psf Roof Zone 3: Positive : 15.655 psf Negative: -89.588 f Wall Zone 4 : Positive : 39.054 psf Negative: �2.469 psf 1 Wall Zone 5 : Positive : 39.054 psf Negative: -51.425 psf • Roof Overhang Zone 2: -57.352 psf Roof Overhang Zone 3: -81.264 psf RC. ENGINEERING Project Title: Roger Chavama, P.E. Engineer: Project ID: FL.Lic. PE #50712 Protect Descr: 780 Tamiami Canal Rd. M_ iami,FL.33144 Printed: 6 JUN 2018, 5:25PM ASCE 7-10 Wind Forces Chpt 28, Pt2 & Chpt 30 Pt2 ��=C:lllser2017,BCr1looC8.29,VENERCA-1 � ENERCALC, INC.1983.2017, 8ui1d:10.17.9.29, Ver.6,17.11.30 'Description: WIND PRESSURES FOR NEW WINDOWS AND DOORS AT 1158 N.E. 99 th.ST. MIAMI SHORES,FL33138 Analytical Values Calculations per ASCE 7-10 V : Basic Wind Speed per Sect 26.5-1 A, B or C 136.0 mph Roof Rise:Run Ratio 4:12 Occupancy per Table 1.5-1 11 All Buildings and other structures except those listed as Category I, III, and IV Exposure Category per 26.7 Exposure C • "". MRH: Mean Roof Height 12.0ft ; .�. ��•� •���:� Lambda: per Figure 28.6-1, Page 305 1.21 • • . : • Effective Wind Area of Component & Cladding 10.0 V2 • : . • Soo*:* Roof pitch for cladding pressure 0 to 7 degrees : • • • • User specified minimum design pressure 10.0 psf • • • • Topographic Factor Kzt per 26.8 1.00 • • • LHD : Least Horizontal Dimension 18.0 ft • • • • • • • • a = max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH)) 3.00 ft max (0.04 * LHD, 3, min(0.10 * LHD, 0.4-01-I)l Design Wind Pressures Minimum Additional Load Case peri8.4.;t =; 6 PSF,pn entye verticalpWO, • Horizontal Pressures ... Zone: A = 49.17 psf Zone: C = 32.79 psf • . : • . . Zone: B = 10.00 psf Zone: D = 10.00 psf • .. • . • Vertical Pressures ... Zone: E = -42.66 psf Zone: G = -29.72 psf Zone: F = -29.72 psf Zone: H = -22.53 psf Overhangs , . . Zone: Eoh = -59.80 psf Zone: Goh = -46.78 psf Component & Cladding Design Wind Pressures Design Wind Pressure = Lambda * Kzt * Ps30 per Eq 30.5-1 Roof Zone 1 : Positive: 16.383 psf Minimum Additional Load Case per 28.4.4 =16 PSF Negative: AO.341 psf on entire vertical plane Roof Zone 2 : Positive : 16.383 psf Negative: -67,663 psf Roof Zone 3: Positive: 16.383 psf Negative : -101.785 sf Wall Zone 4 : Positive : 40.341 psf Negative: -43.705 psf Wall Zone 5 : Positive: 40.341 psf Negative: -53.966 psf Roof Overhang Zone 2: -61.468 psf Roof Overhang Zone 3: -101.277 psf RC. ENGINEERING Roger Chavarria, P.E. FL.Lic. PE #50712 780 Tamiami Canal Rd. Miami,FL.33144 Project Title: Engineer: Project Descr: Project ID: Pnnted: 6 JUN 2018. 5:24PM ASCE 7-10 Wind Forces Chpt 28, Pt2 & Chpt 30, P9 File =CAUsersu2CENGr-NUUME-1ENERCA-1 ENERCALC, INC.1983.2017, Build:10.17.8.29, Ver.6.17.11.30 { - - t Il.......:.at... *�I\In ADCP('.1lnrn rnn a,�,a, ,.,,.,r.�..... ..... �....�� ._ ..__ .. _ vwvl lNuvn . • • . •.• .. • .....+,.w , vl� na_n nlnvvrr0 nlvu uwr%O /A 1 1 1.98 N.t..` U UI,J 1. MIAMI bHUKL5,FL33138 Analytical Values Calculations per ASCE 7 10 V : Basic Wind Speed per Sect 26.5-1 A. B or C 136.0 mph Roof Rise:Run Ratio 4:12 Occupancy per Table 1.5-1 11 All Buildings and other structures except those listed as Category I, III, and IV Exposure Category per 26.7 Exposure C .... . • MRH: Mean Roof Height 12.0ft : •�• •��� ���•:� Lambda: per Figure 28.6-1, Page 305 1.21 " ' "' . ; • • Effective Wind Area of Component 8 Cladding 20.0 ft"2 •••.•. • .• •..•.. Roof pitch for cladding pressure 0 to 7 degrees + • • • • • User specified minimum design pressure 10.0 psf Topographic Factor Kzt per 26.8 1.00 • LHD : Least Horizontal Dimension 18.0 It + • • • • • • • • a = max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH)) 3.00 It max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH�• . . Design Wind Pressures Minimum Additional Load Case per Z.4.4= 36 PSF on entire vertical fIQ*& • Horizontal Pressures ... • Zone: A = 49.17 psf Zone: C = 32.79 psf • • : 0 Zone: B = 10.00 psf Zone: D = 10.00 psf 000000 • • • Vertical Pressures ... Zone: E _ 42.66 psf Zone: G = -29.72 psf Zone: F = -29.72 psf Zone: H = -22.53 psf Overhangs... Zone: Eoh = -59.80 psf Zone: Goh = 46.78 psf Component & Cladding Design Wind Pressures Design Wind Pressure = Lambda * Kzt * Ps30 per Eq 30.5-1 Roof Zone 1 : Positive : 15.343 psf Minimum Additional Load Case per 28.4.4 =16 PSF Negative: -39.301 psf on entire vertical plane Roof Zone 2 : Positive : 15.343 psf Negative : -60.476 psf Roof Zone 3: Positive: 15.343 psf Negative: -84.361 psf Wall Zone 4 Positive: ocxy A : 3B.502 psf -� Negative : 41.939 psf Wall Zone 5 : Positive: 38.502 psf Negative : -50.336 psf Roof Overhang Zone 2: -57.039 psf Roof Overhang Zone 3: -75.093 psf RC. ENGINEERING Project Title: Roger Chavama, P.E. Engineer: Project ID: FL.Lic. PE #50712 Project Descr: 780 Tamiami Canal Rd. Miami,FL.33144 Printed: 6 JUN 2018. 5:24PM ASCE 7-10 Wind Forces Chpt 28, Pt2 & Chpt 30 Pt2 N=CkI%eMMENCr11DOCUME-11ENERCA-1 ENERCALG INC.1983-2017, BWI&10.17.8.29, Ve 6.17.11.30 -Description : WIND PRESSURES FOR NEW WINDOWS AND DOORS AT 1158 N.E. 99 th.ST. MIAMI SHORES,FL33138 Analytical Values Calculations per ASCE 7-10 V : Basic Wind Speed per Sect 26.5-1 A, B or C 136.0 mph Roof Rise:Run Ratio 4:12 Occupancy per Table 1.5-1 II All Buildings and other structures except those listed as Category I, III, and IV Exposure Category per 26.7 Exposure C • • • • MRH : Mean Roof Height 12.0 ft * " Lambda: per Figure 28.6-1, Page 305 1.21 " ' '' `. : '. Effective Wind Area of Component & Cladding 16.0 ft^2 Roof pitch for dadding pressure 0 to 7 degrees """ :. • • • User specified minimum design pressure 10.0 psf •"". • ` • : ` ` Topographic Factor Kzt per 26.8 1.00 0000 ``` ` ` ` ` Goes* • LHD : Least Horizontal Dimension 18.0 ft • • • • • • • • a = max (0.04 * LHD, 3, min(0.10 * LHD, 0.4*MRH)) 3.00 ft max (0.04 * LHD, 3, min(0.10 * LHD, 0.410IRH) f ' • Design Wind Pressures Minimum Additional Load Case per:8.4.4 =y6 PSF Qn entire verticalpW;„ ° Horizontal Pressures ... • ° Zone: A = 49.17 psf Zone: C = 32.79 psf ' 00 ; .. . ; "": Zone: B = 10.00 psf Zone: D = 10.00 psf ' • •' •' Vertical Pressures ... Zone: E = -42.66 psf Zone: G = -29.72 psf Zone: F = -29.72 psf Zone: H = -22.53 psf Overhangs ... Zone: Eoh = -59.80 psf Zone: Goh = -46.78 psf Component & Cladding Design Wind Pressures Design Wind Pressure = Lambda * Kzt * Ps30 per Eq 30.5-1 Roof Zone 1 : Positive : Negative: Roof Zone 2 : Positive : Negative: Roof Zone 3: Positive : Negative: Wall Zone 4 : Positive: Negative: Wall Zone 5 : Positive: Negative: Roof Overhang Zone 2: Roof Overhang Zone 3: 15.759 psf Minimum Additional Load Case per 28.4.4 =16 PSF -39.717 psf on entire vertical plane 15.759 psf -63.351 psf 15.759 psf -91.331 psf .238 psf . PA2 .238 psf.788 psf -57.456 psf -83.321 psf 'Roof Member Component and Cladding Reactions per ASCE 7-10 For Roof Slopes 4:12 Project : ADDITION TO SUSAN PINNAS RESIDENCE Project No.: 1158 N.E. 99th. ST. Miami Shores. FL.33138 6/61/2018 Truss T-2 H B V kd kzt 12 18 136 0.85 1.00 Truss Data: Left OH Main Span Right OH Truss Spac. 1.00 ft. 17.50 ft. 1.00 ft. 2.00 ft. 1-12/3 = Uniform DL 25.0 psf Roof Slope 4 : 12 or 18.43 degrees Uniform LL 30.0 psf Concentrated DL 0.0 Ibs 0.00 ft. Concentrated LL 0.0 Ibs From Left Support Left DL Reaction 487.5 Ibs Right DL Reaction 487.5 Ibs Left LL Reaction 585.0 Ibs Right LL Reaction 585.0 Ibs Roof Pressure Coefficents and Calculated Roof Pressures From 10 to 30 degrees, qz--qh*: Negative Press. Coefficents Pos. Press. Overhang Coefficents Zone 1 Zone 2 & 3 All Zones Zone 2 Zone 3 -0.800 -1.400 0.30 -2.20 -2.50 * Internal pressure 0.18gh included in above calculations to produce maximum loading ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 780 Tamiami Canal RD. Miami, FL.33144 Ph = 305-229-3874 G qh 0.18*qh a 0.896 32.6 5.9 3.00 ft. 102 SF Wind Direction 0�19 Negative Pressures Zone 1 Zone 2 & 3 10verhang Pressures (no int) Zone 2 Zone 3 Positive All Zones Zone 1 (-0.18) -31.9 -51.50 -71.71 -81.49 15.64 -20.21 Uplift Reactions For Zone 2: D + Lr = 1073 Cos theta Sin theta 0.6D + W = -478 10 psf - W = -575 Left Reaction = -812 -770 -257 D + Lr + W = 302 Right Reaction = -631 -598 -199 D + 0.75(Lr + W) = 348 (no increase in stress allowed for this combo) Uplift Reactions For Zone 3: D + Lr = 1073 Cos theta Sin theta 0.6D + W = -497 10 psf - W = -594 Left Reaction = Right Reaction = -832 -630 -789 -598 -263 -199 D + Lr + W = D + 0.75(Lr + W) = 2" 134 009 • 6 • . . • • (go Ihcl)a:e JP -Jets flowed for this combo) • •• • • • • ••• • •• ••• •• • • • •• Downdraft Reactions All Zones: D + Lr = 1073 Cos theta Sin theta 0.6D + W = 435 10 psf - W = 337 Left Reaction = 150 142 47 D + Lr + W = 61119 0 • • o • • • 0 Right Reaction = -239 -227 -76 D + 0.75(Lr + W) _ • . 1033 • • • • (no ink reas a in sires g*Mlojve$ for this combo) • • •• •• • • • • 0 Soo cow 0 NOTE: Zone 2, 3, & OH pressures are applied on the left side. Load Combos are for left reactions only. • • • • • • • • • • ••• • • • ••• • • Roof Member Component and Cladding Reactions per ASIDE 7-10 For Roof Slopes 4:12 Project: ADDITION TO SUSAN PINNAS RESIDENCE Project No.: 1158 N.E. 99th. ST. Miami Shores. FL.33138 6161/2018 Truss T-1 H B V kd kzt 12 18 136 0.85 1.00 Truss Data: Left OH Main Span Right OH Truss Spac. 1.00 ft. 13.00 ft. 1.00 ft. 2.00 ft. L"2/3 Uniform DL 25.0 psf Roof Slope 4 : 12 or 18.43 degrees Uniform LL 30.0 psf Concentrated DL 0.0 Ibs 0.00 ft. Concentrated LL 0.0 Ibs From Left Support Left DL Reaction 375.0 Ibs Right DL Reaction 375.0 Ibs Left LL Reaction 450.0 Ibs Right LL Reaction 450.0 Ibs Roof Pressure Coefficents and Calculated Roof Pressures From 10 to 30 degrees, qz=qh*: Negative Press. Coefficents Pos. Press. Overhang Coefficents Zone 1 Zone 2 & 3 All Zones Zone 2 Zone 3 -0.825 -1.574 0.35 -2.20 -2.80 * Internal pressure 0.18gh included in above calculations to produce maximum loading ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 780 Tamiami Canal RD. Miami, FL.33144 Ph = 305-229-3874 G qh 0.18*qh a 0.896 32.6 5.9 3.00 ft. 56 SF Wind Directior oxkv Negative Pressures Zone 1 Zone 2 & 3 10verhang Pressures (no int) Zone 2 Zone 3 All Zones Positive�-21. -32.8 -57.19 -71.71 -91.24 17.27 Uplift Reactions For Zone 2: D + Lr = 825 Cos theta Sin theta 0.6D + W = -441 10 psf - W = -516 Left Reaction = -702 -666 -222 D + Lr + W = 159 Right Reaction = -505 -479 -160 D + 0.75(Lr + W) = 213 (no increase in stress allowed for this combo) Uplift Reactions For Zone 3: D + Lr = 825 Cos theta Sin theta 0.61) + W = -479 10 psf - W = -554 Left Reaction = -743 -704 -235 D + Lr + VA = • • • 121 • • . . .. Right Reaction = -504 -478 -159 D + 0.75(Lr +;W) = • • ; 184: • • • ; (rt) i4cr4as$ in stress allowed for this combo) • • • • • • Downdraft Reactions All Zones: •• ••• D + Lr = •• 825 • • • •• Cos theta Sin theta 0.6D + W = 355 10 psf - W = 280 Left Reaction = 137 130 43 D + L? t W Q' 9S§' .' . ; .00 Right Reaction = -194 -184 -61 D + 0.75(L ;a'W) • • • • • • .812 • • • • ono increase ir: stress allowed for this combo) • • • • ••• ••• • NOTE: Zone 2, 3, & OH pressures are applied on the left side. Load Combos are for left reactions only. ... • • • • •• 000 • . . • • • •• • 0 0 . ... . . • • • • • • • •• •• 000 • 0 Roof Member Component and Cladding Reactions per ASCE 7-10 For Roof Slopes 4:12 Project: ADDITION TO SUSAN PINNAS RESIDENCE Project No.: 1158 N.E. 99th. ST. Miami Shores. FL.33138 6/61/2018 Truss GT-1 H B V kd kzt 12 18 136 0.85 1.00 Truss Data: Left OH Main Span Right OH Truss Spac. 1.00 ft. 13.00 ft. 1.00 ft. 4.50 ft. LA213 = Uniform DL 25.0 psf Roof Slope 4 : 12 or 18.43 degrees Uniform LL 30.0 psf Concentrated DL 0.0 Ibs 0.00 ft. Concentrated LL 0.0 Ibs From Left Support Left DL Reaction 843.8 Ibs Right DL Reaction 843.8 Ibs Left LL Reaction 1012.5 Ibs Right LL Reaction 1012.6 Ibs Roof Pressure Coefficents and Calculated Roof Pressures From 10 to 30 degrees, qz=qh*: Negative Press. Coefficents Pos. Press. Overhang Coefficents Zone 1 Zone 2 & 3 All Zones Zone 2 Zone 3 -0.825 -1.574 0.35 -2.20 -2.80 * Internal pressure 0.18gh included in above calculations to produce maximum loading ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 780 Tamiami Canal RD. Miami, FL.33144 Ph = 305-229-3874 G qh 0.18*qh a 0.896 32.6 5.9 3.00 ft. 56 SF Wind Direction -� 01 Negative Pressures Zone 1 Zone 2 & 31 10verhang Pressures (no int) Zone 2 Zone 3 Positive All Zones Zone 1 (-0.18) -32.8 -57.19 1 -71.71 1 -91.24 17.27 -21.03 Uplift Reactions For Zone 2: D + Lr = 1856 Cos theta Sin theta 0.6D + W = -992 10 psf - W = -1161 Left Reaction = -1579 -1498 -499 D + Lr + W = 358 Right Reaction = -1137 -1079 -360 D + 0.75(Lr + W) = 479 (no increase in stress allowed for this combo) Uplift Reactions For Zone 3: D + Lr = 1856 Cos theta Sin theta 0.6D + W = -1079 10 psf - W = -1247 Left Reaction = -1671 -1585 -528 D + Lr +All{ =•.. 271. . . . •. Right Reaction = -1134 -1075 -358 D + 0.75(Lr +CW) = ; 41#; ; 4 igcr¢a* in stress allowed for this combo) Downdraft Reactions All Zones: D + Lr = 1866 Cos theta Sin theta 0.61) + W = 800 10 psf - W = 631 Left Reaction = 309 293 98 D + j-t t VO s• 2VV • • , ; • • Right Reaction = -436 -414 -138 D + 0.75(Lr.*Vi): 18Tr3 • jno ircreg9b ig stress allowed for this combo) NOTE: Zone 2, 3, & OH pressures are applied on the left side. Load Combos are for left reactions only. • , • • • • Roof Member Component and Cladding Reactions per ASCE 7-10 For Roof Slopes 4:12 Project: ADDITION TO SUSAN PINNAS RESIDENCE Project No.: 1158 N.E. 99th. ST. Miami Shores. FL.33138 6/61/2018 Truss GT-2 H B V kd kzt 12 18 136 0.85 1.00 Truss Data: Left OH Main Span Right OH Truss Spac. 1.00 ft. 17.50 ft. 1.00 ft. 4.50 ft. L"2/3 = Uniform DL 25.0 psf Roof Slope 4 : 12 or 18.43 degrees Uniform LL 30.0 psf Concentrated DL 0.0 lbs 0.00 ft. Concentrated LL 0.0 lbs From Left Support Left DL Reaction 1096.9 lbs Right DL Reaction 1096.9 lbs Left LL Reaction 1316.3 lbs Right LL Reaction 1316.3 lbs Roof Pressure Coefficents and Calculated Roof Pressures From 10 to 30 degrees, qz=qh*: Negative Press. Coefficents Pos. Press, Overhang Coefficents Zone 1 Zone 2 & 3 All Zones Zone 2 Zone 3 -0.800 -1.400 0.30 -2.20 -2.50 * Internal pressure 0.18gh included in above calculations to produce maximum loading ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 780 Tamiami Canal RD. Miami, FL.33144 Ph = 305-229-3874 G qh 0.18*qh a 0.896 32.6 5.9 3.00 ft. 102 SF Wind Director 0le I, Negative Pressures Zone 1 Zone 2 & 3 Overhang Pressures (no int) Zone 2 Zone 3 Positive All Zones Zone 1 (-0.18) -31.9 1 -51.50 1 -71.71 -81 A 15.64 -20.21 Uplift Reactions For Zone 2: D + Lr = 2413 Cos theta Sin theta 0.6D + W = -1075 10 psf - W = -1295 Left Reaction = -1827 -1733 -578 D + Lr + W = 680 Right Reaction = -1419 -1346 -449 D + 0.75(Lr + W) = 784 (no increase in stress allowed for this combo) Uplift Reactions For Zone 3: D + Lr = 2413 Cos theta Sin theta 0.61) + W = -1118 10 psf - W = -1338 Left Reaction = -1872 -1776 -592 D + Lr +AN =• • • 687• • • • • • Right Reaction = -1418 -1345 -448 D + 0.75(Lr 4 W) = • : 7%2; •• • • ; (rro i5crga4e in stress allowed for this combo) • • s•• • Downdraft Reactions All Zones: • • 000 D + Lr = s • 2413 • • • • • Cos theta Sin theta 0.6D + W = 979 10 psf - W = 759 Left Reaction = 338 321 107 D +1-Tt Vd4Lr` AW . �. ; .0. Right Reaction = -539 -511 -170 D + 0.75(tr.* W); • • •• • • 2344 •• • ` jno iperegft iQ sress allowed for this combo) • • • • ••• ••• • NOTE: Zone 2, 3, & OH pressures are applied on the left side. Load Combos are for left reactions only. 900 . • .• . •. • ... . . . •• •• Roof Member Component and Cladding Reactions per ASCE 7-10 For Roof Slopes 4:12 Project : ADDITION TO SUSAN PINNAS RESIDENCE Project No.: 1158 N.E. 99th. ST. Miami Shores. FL.33138 6/61/2018 Truss J-1 H B V kd kzt 12 18 136 0.85 1.00 Truss Data: Left OH Main Span Right OH Truss Spac. 1.00 ft. 7.00 ft. 0.00 ft. 2.00 ft. L"2/3 = Uniform DL 25.0 psf Roof Slope 4 : 12 or 18.43 degrees Uniform LL 30.0 psf Concentrated DL 0.0 Ibs 0.00 ft. Concentrated LL 0.0 Ibs From Left Support Left DL Reaction 228.6 Ibs Right DL Reaction 171.4 Ibs Left LL Reaction 274.3 Ibs Right LL Reaction 205.7 Ibs Roof Pressure Coefficents and Calculated Roof Pressures From 10 to 30 degrees, qz=qh`: Negative Press. Coefficents Pos. Press. Overhang Coefficents; Zone 1 Zone 2 & 3 All Zones Zone 2 Zone 3 -0.879 -1.951 0.46 -2.20 -3.44 ' Internal pressure 0.18gh included in above calculations to produce maximum loading ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 780 Tamiami Canal RD. Miami, FL.33144 Ph = 305-229-3874 G qh 0.18•gh a 0.896 32.6 5.9 3.00 ft. 16 SF Wind Directior o`X Negative Pressures Zone 1 Zone 2 & 3 Overhang Pressures (no int) Zone 2 Zone 3 Positive All Zones Zone 1 (-0.18) -34.5 -69.46 -71.71-112.27 20.77 -22.78 Uplift Reactions For Zone 2: D + Lr = 503 Cos theta Sin theta 0.6D + W = -394 10 psf - W = -440 Left Reaction = -560 -531 -177 D + Lr + W = -28 Right Reaction = -276 -262 -87 D + 0.75(Lr + W) = 36 (no increase in stress allowed for this combo) Uplift Reactions For Zone 3: D + Lr = 503 Cos theta Sin theta 0.613 + W = -477 10 psf - W = -522 Left Reaction = -647 -614 -205 D + Lr +JW =0 0 • -1*116 • • • • • Right Reaction = -270 -257 -86 D + 0.75(Lr I W) = -21: (rjb ilcrlaV in stress allowed for this combo) • •• • • • • ••• • •• ••• •• • • • •• Downdraft Reactions All Zones: D + Lr = 503 Cos theta Sin theta 0.6D + W = 245 10 psf - W = 199 Left Reaction = 114 108 36 D + J-t: W r (MI • • : Right Reaction = -86 -82 -27 D + 0.75(tri W)� • 516 .0. • • • Sno increase i; s;ess allowed for this combo) • •. % . • • • NOTE. Zone 2, 3, & OH pressures are applied on the left side. Load Combos are for left reactions only. . • • • • • . 000 • • • :so.: ••• 0 • 0 • • • •• •• ••• • • Roof Member Component and Cladding Reactions per ASCE 7-10 For Roof Slopes 4:12 Project: ADDITION TO SUSAN PINNAS RESIDENCE Project No.: 1158 N.E. 99th. ST. Miami Shores. FL.33138 6/61/2018 Truss CJ-1 H B V kd kzt 12 18 136 0.85 1.00 Truss Data: Left OH Main Span Right OH Truss Spec. 1.50 ft. 9.50 ft. 0.00 ft. 2.00 ft. L"2/3 = Uniform DL 25.0 psf Roof Slope 4 : 12 or 18.43 degrees Uniform LL 30.0 psf Concentrated DL 0.0 Ibs 0.00 ft. Concentrated LL 0.0 Ibs From Left Support Left DL Reaction 318.4 Ibs Right DL Reaction 231.6 We Left LL Reaction 382.1 Ibs Right LL Reaction 277.9 Ibs Roof Pressure Coefficents and Calculated Roof Pressures From 10 to 30 degrees, qz=qh*: Negative Press. Coefficents Pos. Press. Overhang Coefficents Zone 1 Zone 2 & 3 All Zones Zone 2 Zone 3 -0.852 -1.765 0.40 -2.20 -3.13 * Internal pressure 0.18gh included in above calculations to produce maximum loading ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 780 Tamiami Canal RD. Miami, FL.33144 Ph = 305-229-3874 G qh 0.18*qh a 0.896 32.6 5.9 3.00 ft. 30 SF Wind Directior a.V\V Negative Pressures Zone 1 Zone 2 & 3 10verhang Pressures (no int) 1 Zone 2 Zone 3 Positive All Zones t Zone 1 (-0.18) -33.6 -63.41 -71.71-101.89 19.04 -21.91 Uplift Reactions For Zone 2: D + Lr = 701 Cos theta Sin theta 0.6D + W = -475 10 psf - W = -539 Left Reaction = -702 -666 -222 D + Lr + W = 34 Right Reaction = -331 -314 405 D + 0.75(Lr + W) = 105 (no increase in stress allowed for this combo) Uplift Reactions For Zone 3: D + Lr = 701 Cos theta Sin theta 0.613 + W = -568 10 psf - W = -631 Left Reaction = -800 -759 -253 D + Lr + W = -58 Right Reaction = -324 -307 -102 D + 0.75(!!r + 36• • • �64ncrease in stress allowed for this combo) Downdraft Reactions All Zones: D + Lr = 701 Cos theta Sin theta 0.6D + W = 329 10 psf - W = 265 Left Reaction = 145 138 46 Do Lr.*W = . • 838 • • • Right Reaction = -115 -109 -36 D + 0.15(�r +W) = :70EC (no incieaie in stress allowed for this combo) . . • • • . . • . • .•• • • . •.• • NOTE: Zone 2, 3, & OH pressures are applied on the left side. Load Combos are for left reactions only. Roof Member Component and Cladding Reactions per ASCE 7-10 For Roof Slopes 4:12 Project: ADDITION TO SUSAN PINNAS RESIDENCE Project No.: 1158 N.E. 99th. ST. Miami Shores. FL.33138 6/61/2018 Truss VT-1 H B V kd kzt 12 18 136 0.85 1.00 Truss Data: Left OH Main Span Right OH Truss Spac. 0.00 ft. 12.00 ft. 0.00 ft. 2.00 ft. L"2/3 = Uniform DL 25.0 psf Roof Slope 4 : 12 or 18.43 degrees Uniform LL 30.0 psf Concentrated DL 0.0 Ibs 0.00 ft. Concentrated LL 0.0 lbs From Left Support Left DL Reaction 300.0 Ibs Right DL Reaction 300.0 Ibs Left LL Reaction 360.0 Ibs Right LL Reaction 360.0 Ibs Roof Pressure Coefficents and Calculated Roof Pressures From 10 to 30 degrees, qz=qh*: Negative Press. Coefficents Pos. Press. Overhang Coefficents Zone 1 Zone 2 & 3 All Zones Zone 2 Zone 3 -0.832 -1.623 0.36 -2.20 -2.88 * Internal pressure 0.18gh included in above calculations to produce maximum loading ROGER CHAVARRIA. P.E. Consulting Engineer. Fla. Lic. # 50712 780 Tamiami Canal RD. Miami, FL.33144 Ph = 305-229-3874 G qh 0.18*qh a 0.896 32.6 5.9 3.00 ft. 48 SF Wind Directior -� 01 Negative Pressures Zone 1 Zone 2 & 31 10verhang Pressures (no int) Zone 2 Zone 3 Positive All Zones Zone 1 (-0.18) -33.0 1 -58.78 1 -71.71 1 -93.96 1 17.72 1 -21.25 Uplift Reactions For Zone 2: D + Lr = 660 Cos theta Sin theta 0.6D + W = -324 10 psf - W = -384 Left Reaction = -631 -504 -168 D + Lr + W = 156 Right Reaction = -415 -394 -131 D + 0.75(Lr + W) = 192 (no increase in stress allowed for this combo) Uplift Reactions For Zone 3: D + Lr = 660 Cos theta Sin theta 0.613 + W = -324 10 psf - W = -384 Left Reaction = -531 -604 -168 D + Lr + W = 166 Right Reaction = -415 -394 -131 D + 0.7%14 W)`-: ; t92.' . (Jo increase in stress allowed for this combo) Downdraft Reactions All Zones: 915 + Or = 'i60 ' Cos theta Sin theta 0.6D + W = 271 10 psf - W = 211 Left Reaction = 96 91 30 D: Lr,,11y _ JP1 . . • Right Reaction = -138 -131 -44 D + 0. 15(Er + W) _ 06380 • (no incrbaCe id stress allowed for this combo) • • •• . . .• • • • • • •.. .•• . NOTE: Zone 2, 3, & OH pressures are applied on the left side. Load Combos are for left reactions only. ••• • • • • ••• • • Arl MI�: DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION nF ACCEPTANCE (NSA) MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 T (786) 315-2599 Mmia _idade govlecono0t Nu-Vue Industries, Inc. 1055 East 29 Street Hialeah, Florida 33013 SCOPE: the use of construction under the, Miami -Dade County RER This NOA is being tss aattion submitted has been reviewed and aaccep governing by mg materials. The document Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Pr Product Control Having Jurisdiction (AHJ). .. • • • • + • This NOA shall not be valid after the expiration date stated below. The Miami -Dade oun ' • Epy4 iAg ht Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dad c � p matenal'f�;ls to +, to have this product or material tested for quality assurance purposes. P • • • •. • perform in the acce of such Wstagjand the AW may epted manner, the manufacturer will incrodtu rpmaterial within Thais �urisdictiod.. -tER • • p or suspend the use of such p p�� %Antrol ..... immediately revoke, modify, P . reserves the right to revoke this acceptance, if it is determined by Miami Db e° coded ! �: • • withVie Florida Bnildtng .... • • Section that this product or material fails to meet the requirements of the applicable � 8 This product is approved as described herein, and has been designed to comp y ....+. . . • Code, including the High Velocity Hurricane Zone. T and NVTH Steel Wpod CopueeRNs + AS, NVBH, NVUH, NVR ++ • • • • DESCRIPTION: Series NVTA, NVT • APPROVAL DOCUMENT: Drawing No. NU-2, titled "NVTA and NVTAS,1•1V Fi �4 and NV .is`i%;> sheets 1 through 4 of 4, dated Ocl/15/2015, prepared by.Nu-Vue Industries, In�.!signed NVRT and NVTH dated 04 15/20 County Product Control renewal stamp with the and sealed by Vipin N. Tolat, P.E., bearing the Notice of Acceptance (NOA) number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None gp, city, "Miami -Dade County Product Control Approved", unless otherwise X,ABELING: Each unit shall bear a permanent label with the manufacturer's name or to ct e, modellseries, and following statement. noted herein. application has been filed and there has been RENEWAL of this NOA shall be considered after a renewal aPP Performance of this product. no change in the applicable building code negatively affecting the TERMINATION of this NOA will occur after the expirationcdateess. M1 if of this has NOA arevision endorsement of in the materials, use, and/or manufacture of the product p any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be causa by termination oods Miami-D de county, lorida, and followed ADVERTISEMENT: The NOA number Precedey Portion of the NOA is displayed, then by the expiration date may be displayed in advertising literature. If any p it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspecti nsists of this pageat the job site atlhand evidence PagestEl and E2, as well as This NOA renews NOA # 12-0130.33 and co approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. OA No• 15-0507 01 a� 24viC N Expiration Date: July 30, 2020 Approval Date: July 30, 2015 P1 age i.. r i NVRT Flat and Twisted Rafter Ties Product 16d Fasteners Maxim' Code Gauge TOTAL Flat 6 4 72! 12 1 NVRT-12 14 10 5 861 16 NVRT-18 14 12 6 998 18 NVRT-18 14 14 7 1135 20 NVRT-20 14 22 NVRT-22 14 24 NVRT-24 14 30 NVRT-30 14 36 NVRT-36 14 48 NVRT-48 14 Notes: 1. Specify "F" for Flat and 'T' for Twisted when ordering. 2, Fastener values are based on a minimum it' thick wood members . 3. • Indicates no. of nags In each connected wood member. 4. See General Notes, shoot I. Uplift Load. e� HALF HALF connected Connected to trues_y to wag tENa� 724 Sea 996 1132 fRoiir �ItoSWGD �tertd� asflrssw by M UPLIFT I r IAM NVRT Twist aftcret ieF0l o Concrete Tie Booms -or Maximum Uplift diameter No. of 16d nails No, of ;" crete to Con Load (Iba) Length product Gauge to Wood Framing Tapcons Code (in) 6 722 4 12 NVRT-12 14 7 $56 5 16 HVRT-18 14 8 8 991 9 1125 18 NVRT-18 14 7 20 NVRT-20 14«»» 22 NVRT-22 14 24 NVRT-24 14» 0 1" 30 NVRT-30 14 11» P o t t» o 36 NVRT-36 14 0 14 NVRT Anchor 48 NVRT-48 Holes dia. Notes: 1. ITW topouns shall be embedded a minimum of 1 " into concrete ne sholl Do not concrete filled masonry. ITW tope Use clydod tlebeam ar tlebeam formed with spacing of 1 as shown• holes 2r and minYnum ep 9 have a min. edge distance of led 2. See General Notes, sheet I. 3• All topcons must be In the same row spaced at 1Yi an cmrters. 0 } Tepcons no not use holes In the oppeo tGee * nodate required tgtcons. .Strap must be long enou o 0 Se• }, VII'Q1N.TdIAT,PB(CNIIJ Note /3 mess' t^br, t�t„A1�.I19847 161>)s I.At4'17E�N i11l� 1'A1'� 2jMln, edge distance • • • • ReinfdrdD#%Wt fbqulred is• • • • • • • •/ �l wltR • • • • • aoncre • leddsonary oC • • • concrete Us horn • • • • ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • ZJI1.5 u- v ue blliag ies.1m. 1053-1059 East 29 Street Hialeah. F1ori 831397 PHONE (305)9 FAX: (305) 694-0398 SBeW I Data' 8 at 4 Awe ire, sots TABLE 1 T.• MvTA nnri Riueted Truss Anchors with Seat NVTAS H Length in Product Code Gouge seat Gouge strop 16 NVTA-16 WAS 212 20 14 IB NVTA-18 WAS 214 20 14 20 NVTA-20 NVTAS 216 20 14 22 NVTA-22 NVTAS 218 20 14 24 NVTA-24 WAS 220 20 14 26 NVTA-26 NVTAS 222 20 14 28 NVTA-28 WAS 224 '20 14 30 NVTA-30 NVTAS 226 20 14 36 NVTA-36 WAS 232 ( 20 14 48 NVTA-48 NVTAS 244 20 14 No. of Fasteners each strop lAoximum Allowable Lood Ibs Uplift Single Strap Uplift Double Straps L1 Single do Double Strops L2 Single NDO7uble10d 5 757 1514 250 6 805 1610 250 500 7 854 1708 250 500 g 902 •1804 250 Soo 9 951� •1902 250 500 10 999 -1998 250 500 11 1048 •2096 250 500 12 1096 •2192 250 500 13 14 1145 1193 •2290 .2290 250 250 500 1 500 -Note: For 8 or more nails per strop. use double truss for double strops. 1, Steel shall conform to ASTM A853, SS grade 33, min, peld 33 ksi, min. tensile strength 45 ksi and min. golwnized cooling of G 60 per ASTM A653. 2. Allowable loads and fasteners ore based on NOS 2005/2012. 3, Design loads ore for S. Pine, specific grovily 0.55. Design loads for other species shall be adjusted per NOS 2005/2012. 4, Allowable uplift loads have been adjusted for food duration factor CD of 1.6. Allowable gravity loads have been adjusted for CD values of 1.0, per table 2.3.2 of NOS 2005/2012. Design loads do not include 33X Increase for steel and concrete. 5. Concrete in Tie beams shall be min. or 2500 psL Concrete Masonry, Grout and mortar in concrete masonry shall be min. of 1500 psi. Concrete masonry shall comply with ASTM C90. 6. Combined load of Uplift. ,.WLI��and L2 Shall l satisfy the following equation. AA 4�_ OAA ! a t1 �wu l2 Aeowoble aplirt + + <=1,0 7. Allowable loads are based on W thick wood members unless otherwise noted. 8, All designs Conform to FOC 2010 and 2014. N TABLE 2 w­TA .,.,rl ai, ten Tn,ss Anchors with Seat NVTAS H Length (in) Product Code Gauge seat Gouge strop 16 NVTA-16 WAS 212 20 14 18 NVTA-18 NVTAS 214 20 14 20 22 NVTA-20 NVTA-22 WAS 216 WAS 218 20 1 20 .14 14 24 NVTA-24 WAS 220 20 14 26 NVTA-26 WAS 222 20 14 28 NVTA-28 WAS 224 20 14 30 NVTA-30 WAS 226 20 14 36 NVTA-36 WAS 232 20 14 48 NVTA-48 WAS 244 20 14 1� 4MIN, li 4" EMB. Parallel Ll WAS i" to wall t" VIPIN N. TOLAT, PE (CIVIL) Nti FL. REG. N 12847 1 I' 15123 LANTERN CRM LANE HOUSTON. TX 77058 •• • • • • • • •• • • • • • • • • • • � " 9 •�. �W fMB. 0 • .00 • • • • • • • • • NVIIf• i• • • 00 •• • •— 0 ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • No. of Fasteners each strop 10d x 1.5" Maximum Allowable Load Ibs Uplift I Single StropI Uplift Double Strops I Ll Single & Double Strops L2 Single 6t Double Strops 5 1032 2236 250 500 6 1127 2254 385 565 7 1136 2272 520 630 8 1144 •22BO 520 630 9 1153 •2306 520 630 10 1161 -2322 520 630 11 1170 •2340 520 630 12 1178 •2356 520 630 13 1187 -2374 520 630 •Note: For 8 or more nails per strap, use double truss for double straps. PRO�DUrOJT. �RBMW13D r awsplyin{ wie IY ilsri4 Perpendicular to wall my RaAK4 cw•sol 'rj1--'rj1 O 1 Reinforcements Required 0 2� a 21. —Concrete Tie Boom Or Tie Beam formed with concrete filled O masonry 141 Holes Old. IV NVTA, NVTAS L tl u— tl ue tn&wtm )oa. 1053-1059 East 29 Street Hialeah, Florid. 33013 PHONE: (305) 694-0397 FAX: (305) 694-0398 NVTA AND NVTAS TRUSS ANCHORS DREG N: I Sheet: I Date: NU-2 late Ape tq sots MIAAM DIADE �,. MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) „ww.miamidRde.gov/economy Nu-Vue Industries, Inc. 1055 East 29's Street Hialeah, Florida 33013 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance proposes, If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisd�elipp. RER reserves the right to revoke this acceptance, if it is determinedby Miami -Dade Cointy Pram .11ontrol..... Section that this product or material fails to meet the requirements of the applicable•4uitdipg cod;.. . . • This product is approved as described herein, and has been designed to comply witt 14e. Viprida Buil$irig .... 6 • Code, including the High Velocity Hurricane Zone. • DESCRIPTION: Series NVSNP, NV/NVTII, NVTHS, NVHC, NVSTA and NYMA+Steel VoQd : • Connectors •"' " 0 • • • • • APPROVAL DOCUMENT: Drawing No. NU-5, titled "Skewed Nail Plate, NV3 • • • • • • 458 =dill! flouble ...... NVTH Straps, NVTH/NVTHS Anchors & NVHC Hurricane Clips and NVSTA & L3.V.WA Heavy Duty • • �-- Anchors with Seat", sheets 1 through 4 of 4, dated 04/15/2015, prepared by Nu-Vue.Industries, lnc,3. s ed • • • • • • .. and sealed by Vipin N. Tolat, P.E., bearing the Miami -Dade County Product Control renewal stamp with the ...... Notice of Acceptance number and expiration date by the Miami -Dade County Produo#eontrol Stow.. . ' MISSILE IMPACT RATING: None • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 12-0130.35 and consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. Mt arnMADe courtTr NOA No. 15-0507.03 Expiration Date: July 30, 2020 Approval Date: July 30, 2015 [IV /:I J Page 1 TABLE 6 NVSTA—Heavy Duty Anchors with 14G NVTH Straps and 1 ply 2013 seat Assembly Product Code 14G Strop Product Code Dimension H (inches) Total No. of Fasteners in Strap 10d x IN' Total No, of Fasteners in 20 GA. Seat 10d x IN' Allowable Loads (Ibs) uplift e e Ll e L2 NVSTA-12H NVTH16 12 5 6 1308 700 1049 6 6 1426 780 1144 NVSTA-14H NVTIiI8 14 7 6 1545 823 1239 NVSTA-16H NVTH2O 16 g 6 1664 887 1335 NVSTA-20H NVTH24 20 9 6 1783 950 1430 x 1t- 0 � o Q NVSTA-22H NVn126 22 NVSTA-24H NVTH28 24 I o 4• r' e �,�• 4. NVSTA-26H NVTH30 26 NVSTA-32H NVTH36 32 Holes DIO. e• NVSTA-44H NVTH48 44 1Y4'� e H .e e1 4' Min. Ell. Walla Concrete Embedment. tYt" UPLIFT �j 1YJ 20C seat 1Y,' 1Y4' NVSTA 12H throght 44H Slot 0.203'X /' L� Trues plate required to transfer uplift to bottom chord. Reinforced Concrete tle beam Mln. 2#5 Top Ac bottom TABLE 7 NVHTA—Heavy Duty Anchors with 14G Double NVTH Straps and 1 ply 20G seat 20H NV Assembly14G Product Code Strop p Product Code Dimension H (inches) Total No. of Fasteners in two Straps 10d x 1Yz' Total No. of Fasteners in 20 GA. Seat 10d x 1;V' Allowable Loads (Ibs) u Iltt a P Uplift s P e L1 _ i L2 NVHTA-12H NVTH16 12 10 6 1772 2078 1050 1450 12 6 1994 2338 1181 1831 NVHTA-14H NVTH18 14 14 6 2215 2598 1312 `1812 NMITA-16H NVTH2O 16 16 6 2437 2858 1444 1994 A 18 6 2658 3117 1575 2175 NVHTA- 20 NVIITA-22H NVTH26 22 NVHTA-24H NVTH28 24 NVHTA-26H NVTH30 26 NVHTA-32H NVTH36 32 NVHTA-44H NVTH48 44 NVHTA H 12H throght 44H 7 4" Min. Concrete Embedrggpt. • • ♦ • • • • • UPLIFT • • • • • • • •L2 • e • • • • GO w • Trues plate required to transfer —uplift to bottom chord. ••• ••• • • RelZrcedeConcrete • .-a- tlesbeam NM. 2#5 • • • Ira • Tqo& bottom • Li y • •i• •• • • • • • • • • • • • • ••• 0 0 0 ••• 0 0 Notes: 1. Nails are necessary In straps and seat to achieve, desing loads 2. See note 6, sheet 1 for combined loading. 3. Nails through chords shot] not force the truss plates. 4. For general notes, see sheet 1. 5. For higher uplift loads, concrete shall be 3000 psi. 6. Based on min. 2500 psi concrete. ;T— PItOIX1C'r RENEYYtiD r amyIri vlre»sl.Ye fhaere Cassel LAT ,� u u f E ( CIVIL) Slde View .20 GA. Hoot ,EEK LANE 1. 0 �-r 10050 N.E. SECOND AVENUE �i0IRt MIAMI SHORES, FLORIDA 33138-2382 TELEPHONE: (305) 795-2207 TRAVIS HENOALL FAX: (3051 756-8972 Planning & Zoning Director DEVELOPMENT ORDER File Number: PZ-5-24-18-43 Property Address: 1158 NE 991h Street Miami Shores FL 33138 Owner/Applicant: Susan Pinnas Address: 1158 NE 99th Street Miami Shores FL 33138 Agent: Rufus Orindare Address: 14610 S. Spur Drive, Miami, FL 33161 Whereas, the applicant Susan Pinnas (Owner), has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Pursuant to Articles IV, V and VI of Appendix A Zoning, Sec. 400 Schedule of Regulations and Sec. 600. Site plan review and approval required for an addition. Whereas, a public hearing was held on May 24, 2018 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Approval is granted as shown on the plans submitted and made. apartps • • • ; • • • approval. • • • • • • .. ... .. . .... 2) Applicant to create and maintain two (2) legal parking spaces on site. 3) Applicant to apply for and obtain all required building pep%it9;from• the• • • • •; • Building Department before beginning work. .... .. .. . .. .. .. .... ....... . Page 1 of 2 ' DO-PZ-5-24-18-43_Pinnas _Addition Reno VISIT US I wujjjni*tn+igsvijIjge cvn+; 4) Applicant to apply for and obtain all necessary permits and approvals from outside agencies. 5) Applicant to obtain all required permits and approvals from the Miami -Dade Department of Regulatory and Economic Resources, Environmental Plan Review Division (DRER, EPRD) and the Miami -Dade Department of Health (DOH/HRS) as required. 6) Applicant to meet all applicable code provisions at the time of permitting. 7) 'This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. Additionally, the applicant must, satisfy all applicable Miami Shores Village Codes, Miami -Dade County Codes, the applicable building and life safety codes required for development, and provide a copy of the development order to the Building Dept. The application with conditions was passed and adopted this 24" day of May, 2018 by the Planning and Zoning Board as follows: Motion to approve subject to Staffs recommendations, with a covenant that the declaration of use is assuring the property is only used for single family purposes, the owner will be required to record this with Miami Dade County and provide a copy to Staff prior to final inspection by Mr. Brady, seconded by Mr. Snow and the vote was unanimous in favor of the Motion. Mr. Snow Yes Mr. Bergman Yes Mr. Hegedus Yes Mr. Brady Yes Chairman Busta Yes 0� ' I'V_ 'low/49/ Date John Busta Chair, Planning Board Page 2 of 2 • • L. 11 • • • • • • • • • • • • • • • • • • • • f • ♦ • • • • 00 DO-PZ-5-24-1843 Pinnas Addition Reno • • • it • • � • • • 1. • Primus Construction Services, Inc. 16536 NW 22nd Street, Pembroke Pines, FI 33028 SUSAN AND CLARK PINNAS BUILDING ADDITION PROJECT 1158 NE 99 STREET MIAMI SHORES, FLORIDA Description Profit and overhead Demo/clearing Survey and testings Foundation (digging/forms) Concrete works (foundation, slab, tie beam, cell fill) Masonry Windows/doors Trusses/sheathing/facial Interior Framing Drywall Plumbing Electrical Mechanical (HVAC) Roofing Painting Dumpster (3 times) Applicances: Dishwasher/washer & dryer: EXISTING Fridge: EXISTING Materials Labor/sub- Unit Quantity Cost/Equipment contractors/Cost Total LS 1 $ 10,000.00 $ 10,000.00 LS 1 $ 3,000.00 $ 3,000.00 LS 1 $ 4,000.00 $ 4,000.00 LS 1 $ 3,500.00 $ 3,500.00 $ 7,000.00 LS 1 $ 7,000.00 $ 10, 000.00 $ 17, 000.00 LS 1 $ 6,800.00 $ 6,800.00 ✓ LS 1 $ 12,000.00 $ 3,000.00 $ 15,000.00 LS 1 $ 12,000.00 $ 5,400.00 $ 17,400.00 � LS 1 $ 3,000.00 $ 4,000.00 $ 7,000.00 LS 1 $ 3,200.00 $ 6,200.00 $ 9,400.00 LS 1 $ 10,000.00 $ 10,000.00 LS 1 $ 12,000.00 $ 12,000.00 LS 1 $ 8,500.00 $ 8,500.00 LS 1 $ 7,200.00 $ 7,200.00 LS 1 $ 1,200.00 $ 2,400.00 $ 3,600.00 ✓ LS 1 $ _ 2,100.00 $ 2,100.00 LS 1 $ - $ - $ - _ LS 1 $ - $ - $ - • • • • • ► • r • • • Y • • • • • r • • • • • ••• f • • • • • • • • • • • • • • • • • • • • • • • • • FORM R405-2017 . FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1158 NE 99th ST 06-12-18G Builder Name: Street: 1158 NE 99th STREET Permit Office: MIAMI SHORES City, State, Zip: MIAMI SHORES, FL, Permit Number: Owner: Jurisdiction: 232600 Design Location: FL, Miami County: Miami -Dade (Florida Climate Zone 1 ) 1." New construction or existing Addition 9. Wall Types (1287.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 287.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 2(2) d. N/A R= ft2 10. Ceiling Types (943.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 • J3.00 W 6. Conditioned floor area above grade (ft2) 943 b. N/A R= • 0 0.0 • ft2 0 0 0.0 • • •4R= 2 Conditioned floor area below grade (W) 0 11 Ducts • 0964, 9•• a ft2 ' • 7. Windows(203.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: HALC":" ' E 3200 • • • • • a. U-Factor: Sgl, U=1.10 203.04 ft2 : SHGC: SHGC=0.30 12. Cooling • . • • • • • kBtu/hr• Efficiency: b. U-Factor: N/A ft2 systems . • • . .... SHGC: a. Central Unit • •. • • • 23.1 SEFR:16.50 • • ••••• c. U-Factor: N/A ft2 " ' • • • • • • • • SHGC: 13. Heating systems • •..•.• • • . kBtu/hr •Efficiency • • d. U-Factor: N/A ft2 a. Electric Strip Heat ' • 1:1 1 (SOP:1.000 • • • • • SHGC: ; • :••••: Area Weighted Average Overhang Depth: 1.000 ft. 0•0 • • • • • • . • Area Weighted Average SHGC: 0.300 14. Hot water systems - None required 000 .0 • a. Cap: N/A 8. Floor Types (943.0 sqft.) Insulation Area EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 943.00 ft2 b. Conservation features b. N/A R= ft c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.215 Total Proposed Modified Loads: 48.24 PASS Total Baseline Loads: 49.02 1 hereby certify that the plans and specifications covered by Review of the plans and 'CKE S74 p, this calculation are in compliance with the Florida Energy specifications covered by this y0 O Code. calculation indicates compliance with the Florida Energy Code. f. plot I PREPARED BY: Before construction is completed a DATE: this building will be inspected for compliance with Section 553.908 y * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. WE'�� OWNER/AGENT: BUILDING OFFICIAL: DATE. DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). a 6/12/2018 2:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1158 NE 99th ST 06-12-18G Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 943 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 1158 NE 99th STREET Permit Office: MIAMI SHORES Cross Ventilation: No County: Miami -Dade Jurisdiction: 232600 Whole House Fan: No City, State, Zip: MIAMI SHORES, Family Type: Single-family FL, New/Existing: Addition Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL_MIAMI_INTL_AP 51 90 70 75 149.5 •"56. Low • • •••• •••••• BLOCKS 0 eggs ' ...... • • .... . Number Name Area Volume ...... 1 Entire House 943 8487 *see** • • . go: ..... SPACES • •"' • ••••• .. .. . ...... Number Name Area Volume Kitchen Occupants Bedrooms Infi ID • Finished Cooled Heated 1 MASTER BEDROO 320 2880 No 2 1 1 ; � %es •••••• • Yes 6.90.0 • Yes • •••••• ' ' 2 HER WIC 70 630 No 0 1 Yes •Y • es Yes 3 HIS WIC 60 540 No 0 1 Yes Yes Yes 4 MASTER BATH 100 900 No 0 1 Yes Yes Yes 5 BEDROOM 243 2187 No 1 1 1 Yes Yes Yes 6 BATH 50 450 No 0 1 Yes Yes Yes 7 WIC 60 540 No 0 1 No Yes Yes 8 HALL 40 360 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 56 ft 0 320 ft2 — 0 1 0 2 Slab -On -Grade Edge Insulatio HER WIC 7 ft 0 70 ftz ---- 0 1 0 3 Slab -On -Grade Edge Insulatio HIS WIC 5 ft 0 60 ft' ____ 0 1 0 4 Slab -On -Grade Edge Insulatio MASTER BATH 11 ft 0 100 ft' ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BEDROOM 46 ft 0 243 ft' ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BATH 9ft 0 50 ftZ _ 0 1 0 7 Slab -On -Grade Edge Insulatio WIC 1 ft 0 60 ftz — 0 1 0 8 Slab -On -Grade Edge Insulatio HALL 9ft 0 40 ftZ — 0 1 0 6/12/2018 2:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 972 ft2 0 ft2 Medium 0.9 No 0.9 No 0 14 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 943 ft2 N Y CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 320 ft2 0.1 Wood 2 Under Attic (Vented) HER WIC 30 Blown 70 ft2 0.1 + '+•' * � �Uod 3 Under Attic (Vented) HIS WIC 30 Blown 60ft2 0:1 ... Wpod �• 4 Under Attic (Vented) MASTER BATH 30 Blown 100 ft2 • • • �'l71 Vlod • + • • + + 5 Under Attic (Vented) BEDROOM 30 Blown 243ft2 +el 'Wood ;....; 6 Under Attic (Vented) BATH 30 Blown 50 ft2 ' ....i:L1 • • mod 7 Under Attic (Vented) WIC 30 Blown 60 ft2 • • • • +Ot1 • Wood •*Poo 8 Under Attic (Vented) HALL 30 Blown 40 ft2 " "0.1 ' Wood • • • •: • WALLS Adjacent Cavity Width Height blheath ng Framing.*Solar 'Below • nrnt Space To Wall Type 1 E Exterior Concrete Block - Ext Indi/4STER BE 4.1 26 0 9 0 234.0 ft2 0 0 0.5 0 2 S Exterior Concrete Block - Ext Ind/4STER BE 4.1 15 0 9 0 135.0 ft2 0 0 0.5 0 3 W Exterior Concrete Block - Ext Ind/ASTER BE 4.1 15 0 9 0 135.0 ft2 0 0 0.5 0 4 W Exterior Concrete Block - Ext InsuHER WIC 4.1 7 0 9 0 63.0 ft2 0 0 0.5 0 5 W Exterior Concrete Block - Ext InsuIHIS WIC 4.1 5 0 9 0 45.0 ft2 0 0 0.5 0 6 W Exterior Concrete Block - Ext IndA4STER BA 4.1 11 0 9 0 99.0 ft2 0 0 0.5 0 7 E Exterior Concrete Block - Ext Ins6EDR00M 4.1 14 0 9 0 126.0 ft2 0 0 0.5 0 8 S Exterior Concrete Block - Ext InsfiIEDROOM 4.1 18 0 9 0 162.0 ft2 0 0 0.5 0 9 W Exterior Concrete Block - Ext Insb3EDROOM 4.1 14 0 9 0 126.0 ft2 0 0 0.5 0 10 E Exterior Concrete Block - Ext Insul BATH 4.1 9 0 9 0 81.0 ft2 0 0 0.5 0 11 W Exterior Concrete Block - Ext Insul HALL 4.1 9 0 9 0 81.0 ft2 0 0 0.5 0 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Single (Tinted) Yes 1.1 0.3 N 17.8 ft2 1 ft 0 in 1 ft 0 in None None 2 E 1 Metal Single (Tinted) Yes 1.1 0.3 N 49.3 ft2 1 ft 0 in 1 ft 0 in None None 3 W 3 Metal Single (Tinted) Yes 1.1 0.3 N 49.3 ft2 1 ft 0 in 1 ft 0 in None None 4 W 6 Metal Single (Tinted) Yes 1.1 0.3 N 6.1 ft2 1 ft 0 in 1 ft 0 in None None 5 S 8 Metal Single (Tinted) Yes 1.1 0.3 N 33.3 ft2 1 ft 0 in 1 ft 0 in None None 6 E 10 Metal Single (Tinted) Yes 1.1 0.3 N 7.2 ft2 1 ft 0 in 1 ft 0 in None None 6/12/2018 2:58 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V/ # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 7 W 11 Metal Single (Tinted) Yes 1.1 0.3 N 40.0 ft2 1 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 990.2 54.36 102.23 .284 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/Supplemen None COPA 17.06 kBtu/hr 1 sys#1 owes COOLING SYSTEM • . . .... ...... # System Type Subtype Efficiency Capacity Air Fiji, SHR f Block Ducts • 1 Central Unit/Supplemental for Split SEER: 16.5 23.1 kBtu/hr 780 4*6 • • 0.7 f1 sys#1 a ••offs SOLAR HOT WATER SYSTEM .... .... ..... Aid . . FSEC ColleCtoi 2. Sto- 14• • • Cert # Company Name System Model # Collector Model #3 • • Volume, , a f FEF • • • • • ft2 fofosf sofas* as f so • DUCTS • • • 00 — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 320 ft2 Attic 155 ft2 Default Leakage HALL (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb Mar HeatinHJan HFeb Mar A r Ma rj Jun �Xj Jul rj Au rlSe [ ]Oct [ j Nov E Apr IMay Jun Jul AuSep (] Oct [X] Nov Dec Dec X Ventin Jan Feb X Mar [xl A r May Jun Jul Aug Se [X] Oct [X] Nov Dec 6/12/2018 2:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 HER WIC Default(8 lbs/sq.ft. ft2 ft 0.3 0 HIS WIC• ' Default(8 Ibs/sq.ft. ft2 ft 0.3 * •.14ATER RAT-H • Default(8 Ibs/sq.ft. ft2 ft 0.3 "' ;'BEDROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 . .... . WIC . .. . .: • • • • • • Default(8 Ibs/s .ft. ft2 ft 0.3 • • • • • • HALL' ' ""' Name: Test Rater Rating Compant: Test Rater . . . . .• Signature: • ... • • .... • • . Date: 6/12/2018 2:58 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*=98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity' • • %.1 a) Split system .'. SEER* 16.5 :• 5. Is this a worst case? (yes/no) 5. No b) Single package ' SEER". �. c) Ground/water sour @'WF_R/COP " ""' • 6. Conditioned floor area (sq. ft.) 6. 943 d) Room unit/PTAC •--- -- EER ' :....: e) Other • • • • ' 7. Windows, type and area • • • • " " ":' �. a) U-factor: (weighted average) 7a. 1.100 • • • • • • ""' b) Solar Heat Gain Coefficient (SHGC) 7b. 0.300 14. Heating system: • • • Capacity 17.1 • •' • ;' c) Area 7c. 203.0 a) Split system heat pump • - HSPF • • b) Single package heat pump HSPF • 000000 8. Skylights c) Electric resistance - - C04" * 01.0 • • • a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural.gas : AFUE • • - b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFU -- - f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 1158 NE 99th STREET City/FL Zip: MIAMI SHORES. FL 6/12/2018 2:58:26 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 232600 Permit #: Job Information Builder: Community: Lot: NA Address: 1158 NE 99th STREET City: MIAMI SHORES State: FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, orfERl Melfwo .' Goof . • ,..•.. •. fo O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakjgr, 1p.of not excegding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. • ; • O PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an-A:0214ge rat;gfjpijxceediiij the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled to infiltration, sft-section ACH80. ACH(50) specified on Fo►m R405.2017-Energy Calc (Performance) or R406-2017 (ERI): • r rvoo • x 60 _ 8487 = Method for calcotatim? buildigl tglfjwe: ' CFM(50) Building Volume ACH(50) O Retrieved from architectural plans F-1 PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSURESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 6/12/2018 2:58:40 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -- wrightsoft• Project Summary Entire House For. 1158 NE 99th ST 1158 NE 99th STREET, MIAMI SHORES, FL Notes: Job: Date: 064 2-18 By: Design Information' ...... .. ...... Weather. Miami, FL, US • • • • • • • Winter Design Conditions Summer Design Co6ditioils.'.: ..... Outside db 52 OF Outside db • *: • •: 91. Z. ""' Inside db 70 OF Inside db • • • • 75 OF • • • • • • Design TD 18 OF Design TD • • • • • • 16 :F .' Daily range 0 .L Relative humidity 9 • he - 18 ...... Moisture difference grAb ' ...... Heating Summary Sensible Cooling Equipment Load-dRing Structure 12157 Btuh Structure 14473 Btuh Duds 2188 Btuh Duds 2605 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping Equipment load Method Construction quality Fireplaces 0 Btuh 14345 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 16361 Btuh Simplified Average 0 AreangHea C014 Volume (ft) 8487 8487 Ai r changes/hour 0.45 023 Equiv. AVF (cfm) 64 33 Heating Equipment Summary Make CARRIER Trade Model FV4CNF003T00 AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 5.0 kW 17061 Btuh 20 0 780 cfm 0.054 cfm/Btuh 0 in H2O Latent Cooling Equipment Load Sizing Structure 4872 Btuh Ducts 960 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5832 Btuh Equipment Total Load (Sen+Lat) 22192 Btuh Req. total capacity at 0.72 SHR 1.9 ton Cooling Equipment Summary Make CARRIER Trade Cond 24ACB724AO03 Coil FV4CNF003T00 AHRI ref Efficiency Sensible cooling Latent 000li ng Total doling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16.5 SEER 16700 Btuh 6400 Btuh 23100 Btuh 780 cfm 0.046 cfm/Btuh 0 in H2O 0.75 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .r` Wrl htSoft' 2018-Jun-1214:56:44 9 Rght-Suite®Universal 201717.028 RSW8046 Page 1 ...91h ST\CPLCS 11 58\1 158 NE 99th ST 06-12-18G rup Calc= MJB Front Door faces N - wrightsoft• Right-J® Worksheet JOb. Entire House Date: 06-1248 air 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 143.0 ft 56.0 ft 3 Room height 9.0 It 9.0 ft head000l 4 Roonndimensions 1.0 x 320.0 It 5 Room area 943.0 V 320.0 ft Ty Construction U-value Or HTM Area (M Load Area (IF) Load number (BtuhfiF--F) (Btu hAF) or perimeter (tl) (Btrih) or perime4er (1l) (Btuh) Heat Cod Corm N/P/S Heat Cod Gross N/P/S Heat Cod 6 13AAocs 0.143 a 2.59 2.87 441 367 950 1055 234 167 432 480 10A-m 1.100 a 19.91 35.71 18 0 358 643 18 0 358 643 1Ah1om 1.100 a 19.91 51.01 7 0 139 357 0 0 96990 0 1A-hlom 1.100 a 19.91 51.01 49 0 976 2500 0 49 0 0 2500 w 11 13AAocs 0.143 s 2.59 2.87 297 264 683 759 0135 0 • • 135 000 9 1A-h1om 1.100 s 19.91 24.72 33 66 657 816 • • 0 000 • 0 WL�13A-flocs w 2.59 2.71 540 454 1796 1428 01 • . 86 •4 a i7 10A-m 1.100 1.100 w 19.91 35.71 40 0 796 1428 • 0 - a 1A-h1om 1.100 w 19.91 51.01 6 0 119 308 • off • • • 0 • 0 • 0 1A-h1om 1.100 w 19.91 51.01 49 0 976 2500 a • 0 0 0 97 C 16D-301d 0.032 0.58 1.11 943 943 546 1050 •320 • 320 • • 1 F 22A-tph 1.358 24.58 0.00 943 143 3515 0 3M • • 56 • • 1876 • •(b •••••• • • ••• • 000 •••••• • • • • • • • • • • ••• •• • •• • • • • •• • • 6 c)AED excursion 0 -322 Envelope loss/gain 10891 12718 4876 6792 12 a) Infiltration 1256 565 496 221 b) Room ventilation 10 0 0 0 13 Internal gains: OCCuparris@ 230 3 690 2 460 Appliances/bOw 500 200 SubtDtal (lines6 to 13) 12157 14473 5371 7673 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 SubtDW 12157 14473 5371 7673 15 Dud loads 18o/u 180/6 2188 2605 18% 18% 967 1381 TTotal room load 14345 17078 6338 9054 Air required (ckn) 780 780 345 414 • Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A& � wrightsoft' Right -Suite® Universal 201717.028 RSU08046 2018 Jun-121 Page 1 9th STG&CS 11 58\1 158 NE 99M ST 06-12-18G rup Calc= MJ8 Front Door faces: N 9 -�- wrightsoft• Right-J® Worksheet Job' Entire House DAD: 06-1248 W 1 Room name HER WIC HIS WIC 2 Exposed wall 7.0 ft 5.0 ft 3 Room height 9.0 It heat/aod 9.0 It heaV000l 4 Room dimensions 1.0 x 70.0 It 1.0 x 60.0 ft 5 Room area 70.0 ft' 60.0 fF Ty Cons"on U-value Or HTM Area (tl?) Load Area (ft) Load number (Btuh/W-°F) (Btu or perimeter (tl) (Btuh) or perimeter (tl) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/PIS Heat Cod 6 13A4ocs 0.143 a 2.59 2.87 0 0 0 0 0 0 0 0 10A-m 1.100 a 19.91 35.71 0 0 0 0 0 0 0 0 lA-hlom 1.100 a 19.91 51.01 0 0 0 0 0 0 •••• 0 0 lA-hlom 1.100 a 19.91 51.01 0 0 0 0 0 0• 0 0 tr----G 11 13A-4ocs 0.143 s 2.59 2.87 0 0 0 0 0 ••• 0 690•0 001 1A-hlom 1.100 s 19.91 24.72 0 0 0 0 go • 0 • • • 0 0 13A-4ocs 0.143 w 2.59 2.87 63 63 163 181 45 oils 129 10A-m 1.100 w 19.91 35.71 0 0 0 0 •• :•• 0 66 0•(? 1A-hlom 1.100 w 19.91 51.01 0 0 0 0 ••tl••• 0 • 0 • 0 IA-hlom 1.100 w 19.91 51.01 0 0 0 0 • • 0 • 0 • •8• C 16D-30td 0.032 - 0.58 1.11 70 70 41 78 • • 60 • • 4 • 67 F 22A-tph 1.358 - 24.58 0.00 70 7 172 0 6S • • 5 • • 4M • •p •••••• • • • ••• •• •• • ••• • • • • 000 • • • • • • • • • • • • 00000 • 6 c)AED excursion 1 -12 -9 Envelope loselgain 376 247 274 187 12 a) Infiltration 62 28 44 20 b) Room ventilation 0 0 0 0 13 Iniemalgain& Occupants@ 230 0 0 0 0 Applianoeslother 0 0 SublotalQines6to13) 438 275 318 207 Lessexemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Submhal 438 275 318 207 15 Dud loads 180/0 180/6 791 501 18% 18% 57 37 Total room load 516 325 1 376 245 Air required (dim) 28 15 20111 •• Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Aft414- wrightSOtft' FPoght-Sui*SLJniversal 20l7l7.028 RSW8046 2018 Jun-121 Page 2 ...9th ST\CALCS 11 58\1 158 NE 99th ST 06-12-18G rup Calc= lvlJB Front Door faces: N g r• - 1- wrightsofC Right-J® Worksheet Job: Entire House Data: 06-1248 By. 1 Room name MASTER BATH BEDROOM 2 E)posed wall 11.0 It 46.0 it 3 Room height 9.0 ft heaftol 9.0 ft heabbool 4 Roomdimensions 1.0 x 100.0 It 1.0 x 243.0 ft 5 Room area 100.0 fF 243.0 fF Ty Construction U-value Or HTM Area (ff) Load Area (fn Load number (BWh&--F) (BAa or perimeter (IQ (Bhp) or perimeter (ft) (Bluh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 13A4ocs Q143 a Z59 Z87 0 0 0 0 126 126 326 362 10A-m 1.100 a 19.91 35.71 0 0 0 0 0 0 0 0 1A-hlom 1.100 a 19.91 51.01 0 0 0 0 0 0 •.900 0 lA-hlom 1.100 a 19.91 51.01 0 0 0 0 0 0• S 0 W 11 13A-4ocs 0.143 s 2.59 2.87 0 0 0 0 �162 • • • 129 • • *A4 '9Tt lA-hlom 1.100 s 19.91 24.72 0 0 0 0 93 33 • • • 651 816 13A-4ocs 0.143 w 2.59 2.87 99 93 241 267 1 126 8329 362 10A-m 1.100 w 19.91 35.71 0 0 0 0•• 0 • A lA-hlom 1.100 w 19.91 51.01 6 0 119 306 000090 0 • 0 • 0 1A-hlom 1.100 w 19.91 51.01 0 0 0 0 • • • 0 •001 C 16D-30tl 0.032 - 0.58 1.11 100 100 58 111 Q • 243 • 0014: 271 F 22A-tph 1.358 - 24.58 0.00 100 11 270 0 20• • 46 • • 1*6 • *Oj • • • ••• •• • 6 c)AED excursion 1 71 -108 Ernelope loss/gain 688 755 2915 2073 12 a) Infiltration 97 43 407 182 b) Room ventilation 0 0 0 0 13 Internal gains Occupants @ 230 0 0 1 230 Applianoesbther 0 100 Subtotal (lines 6 to 13) 786 799 3322 2585 Less wdemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 786 799 3322 2585 15 Dud loads 180/0 18% 141 144 18% 180/0 598 465 Total room load 927 943 3920 3050 Air required (dm) 50 43 213 139 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrlghftsOfft' Right-Suite®Universal 201717.028 RSU08046 Pa 2018 Jun-12 1 ge 3 ._91h STtCALCS 11 58\1 158 NE 99th ST06-12-18G rup Calc= MJ8 Front Doorfaces: N 9 . - wrightsofC Right-J® Worksheet Job: Entire House Date: 06-1248 W- 1 Room name BATH WIC 2 Exposed wall 9.0 It 0 It 3 Room height 9.0 ft heatl000l 9.0 It heatbod 4 Roomdimensons 1.0 x 50.0 ft 1.0 x 60.0 It 5 Room area 50.0 f 60.0 ff Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuhf-°F) or perimeter (ft) (B1uh) or perimeter (fl) (Btuh) Heat I Cod Gross NF/S Heat Cool Gross NOS Heat Cool 6 Vfl cs 13A.100 a 259 2. 81 74 192 213 0 0 0 0 10�4-m -m 11.100 a 19.91 35.71 71 0 0 0 0 0 0 0 0 - ^` IA-h1om 1.100 a 19.91 51.01 7 0 139 357 0 0 • • • d 0 L�4-�.(G 1A-hlom 1.100 a 19.91 51.01 0 0 0 0 0 00 0 11 w 13F4-0ocs 0.143 s 2.59 2.87 0 0 0 0 0 • • • 0 90690 • t 1A-hlom 1.100 s 19.91 24.72 0 0 0 0 40 • 0 • • • 0 vh 13A-4ocs 10A{n .1 1.10000 1 w w 2.59 19.91 2. 35.71 71 0 0 0 0 0 0 0 0 • • • • 0 • 0 • • 0 •0 1A-h1om 1.100 w 19.91 51.01 0 0 0 0 • 000 0 • 0 • 0 1A-hlom 1.100 w 19.91 51.01 0 0 0 0 0bt0 0 0 4) C 16D-301d 0.032 0.58 1.11 50 50 29 56 • • • 60 •• • 67 F 22A-tph 1.358 - 24.58 0.00 50 9 221 0 • • 0 • • • • O •• •• • •• •• ••• • •••••• • • •• • • 6 c)AED excursion -11 -11 Envelope lossi fain 581 614 35 56 12 a) Infiltration 80 36 0 0 b) Room ventilation 0 0 0 0 13 Inlemalgains Oowpants@ 230 0 0 0 0 Applianceslolher 0 200 Sublotel (lines6 to 13) 661 650 35 256 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 661 650 35 256 15 Duct loads 180/0 180/0 119 117 18% 16% 6 46 Total room load 780 767 41 302 Air required (clm) 42 35 2 14 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. a wri ht5oft' 2018-Jun-1214:56:44 9 Right-Sui"Universal 201717.028 RSU08046 Page 4 ft ST\CALCS 11 58\1 158 NE 99th ST06-12-18G rup Calc= MJ8 Front Doorfaoes: N -�- wrightsoft, Right-J® Worksheet Entire House Job: Date: 06-1248 1 Room name HALL 2 Exposed wall 9.0 ft 3 Room height 9.0 ft heaUcool 4 Room dimensions 1.0 x 40.0 It 5 Room area 40.0 IF Ty Construction U-value Or HTM Area (" Load Area Load number (Stuhlf ,'F) (BbLi or perimeter yo (l3hih) or perimeter Heat Cod Gross NrPIS Heat Cod Gross NiPS Heat Cod 6'h 13A-4ocs 0.143 a 2.59 2.87 0 0 0 0 10A-m 1.100 a 19.91 35.71 0 0 0 0 1A-hlom 1.100 a 19.91 51.01 0 0 0 0 1Xh1om 1.100 a 19.91 51.01 0 0 0 0 • ••••• V,\/ I—G 11 13A-4ocs 0.143 s 2.59 2.87 0 0 0 0 • • 0000 • • 1A•hlam 1.100 s 19.91 24.72 0 0 0 0 • • 000 � �--�a 13A4ocs 0.143 w 2.59 2.87 81 41 106 118 • • • • • • 10A-m 1.100 w 19.91 35.71 40 0 796 1428 : • • ;LAG 1A-hlom 1.100 w 19.91 51.01 0 0 0 0 • • • • • • • 1A-h1om 1.100 w 19.91 51.01 0 0 0 0• • • • •• C 16D-301d 0.032 0.58 1.11 40 40 23 45 • • • • • F 22Artph 1.358 24.58 0.00 40 9 221 0 • • • • • • • • 6 c)AED excursion 1 401 Envelope loss/gain 1147 1992 12 a) Infiltration 80 36 b) Room ventilation 0 0 13 Internal gains Oocupants@ 230 0 0 Appliancesbther 0 SublDtal(lines6to13) 1227 2028 Lessexernalload 0 0 Less transfer 0 0 Redistribution 0 0 14 Sublotal 1227 2028 15 Dud loads 180/0 180/0 221 365 Total room load 1447 2393 Air required (cfrn) 791 109 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. * wrightsolFt' Rght-Suite®Universal 201717.028 RSU08046 2018 Jun-12 1 Page 6 9Ih Sf\CALCS 11 58\1 158 NE 991h ST06-12-18G rup Calc= MJ8 Front Doorfaces: N MiAMI•tX4bE Department of Regulatory and Economic Resources Impact Fee Assessment Process Number•• M:018016W7-0 • Batch: Collection Number: F�dio: • TV2050401*V Site Address: 1158 NE 99 ST 't'ee'gayer: • • •;... Assessment Date: 08/20/2018 • • • • • • • • • • • • • M • • � • . • Disclaimer Note: ROAD/FIRE/POUPKS impact fees • • • • • . will increase on 101112018 ' , • • • • • • • Online Payment available at: • • • •' • • • . ; • • • a • • https://www8.miamidade.gov/apps/rer/ImpactFeesPayments/default.aspx • • • • • • • �. • • • Payment can be made by Credit Card, Cash, Check or Cashiers's Check • • • Payable to Miami Dade County Fee Type i Dist Id i Category Cat Category Description I Units Fee I Extended Amount Deferred Code I Sui I Amount AREA i $ 000; 1.0 5002 100 UNIT SIZE (SQ FT) 695 $0 9180 $638.01 e Assessment Total Amount: $638.01 Deferral Amount: $0.00 Current Balance Due: $638.01 i Report run on: August 20, 2018 08:54 AM Page 1 of 1