Loading...
ELC-19-2496 (2)Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 ry Iin113'� Issue Date:11/01/2019 Location Address Parcel Number 11300 NE 2ND AVE, Miami Shores, FL 33161 1121360000050 rnntnrtc Permit No.: ELC-10-19-2496 Permit Type: Electrical - Commercial Work Classification: Alteration Permit Status: Approved Expiration: 04/29/2020 BARRY UNIVERSITY INC Owner BARRY UNIVERSITY 11300 NE 2 AVE, MIAMI SHORES, FL 331616628 RYBB FIRE ALARM INC Contractor DALIEN RAMIREZ Business: 3059032287 RYBBSERVICE@GMAIL.COM Description: ADD DUCT DETECT TO FIRE ALARM SYSTEM Valuation: $ 23,520.00 Inspection Requests: 305-762-4949 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $14.40 DBPR Fee $10.58 DCA Fee $7.06 Education Surcharge $4.80 Permit Fee $655.60 Scanning Fee $9.00 Technology Fee $17.64 Total: $769.08 Payments Date Paid Amt Paid Total Fees $769.08 Credit Card 10/22/2019 $50.00 Credit Card 11/01/2019 $719.08 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futherm r5Z 1'authorj;Q the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Copf&ctor / Agent Date November 01, 2019 Page 2 of 2 f RE.CEIVED Miami Shores Village KITa� � �q Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 ' Tel: (305) 795-2204 Fax: (305) 756-8972 L ' INSPECTION LINE PHONE NUMBER: (305) 762-4949� FBC 20 G�� q BUILDING Master Permit No. L, LC -1 0 - I C1 PERMIT APPLICATION BUILDING ❑■ ELECTRIC ❑ ROOFING Sub Permit No. ❑ REVISION ❑ EXTENSION RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: Barry University - 11300 NE 2nd Avenue - NHS - Siena Building City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 4 it Z/ �,6 60[h 0060 Is the Building Historically Designated: Yes NO. Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Barry University Phone#: 305.899.3995 Address: 11300 NE 2nd Avenue City: Miami Shores State: FL Tenant/Lessee Name: Phone#: Email: f1 ygn S'e'q JGF IO G.ti� ��, G ►�i`f p: 33161 CONTRACTOR: Company Name: Aye3 F/RE 4144M, o-Je_ Phone#: 305-103-2Z9� Address: 7311 AJW ! z sT dj.7 z City: til. 7 State: All/ Zip: 3 31 26 Qualifier Name: 4x7=F4 /QAr" iIt Ig -4 Phone#: 796 -3 Zf1 - 3 iM 3 State Certification or Registration #: EL` 13'00.72 7-B Certificate of Competency #: DESIGNER: Architect/Engineer: Address: Phone#: City: State: Zip: Value of Work for this Permit: $ ' jE3.52 0 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: X A ADD b uG r J4 for c Lb 1M eei wsr_i 4 Specify color of color t(h�ru tile: Submittal Fee $ 0 .�` ` Permit Fee $ ��51•��"� CCF $ Dn CO/CC $ �( Scanning Fee $ Radon Fee $ - �110 D//BPPR(($t0- �D Notary $ Technology Fee $ Training/Education Fee $ -CJ V Double Fee $ 5y Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ vl • ��) (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection a will be charged. Signature Signature OWNER or AGENT The _f regoing instrument was acknowledged before me this lUday of —VPT(;A 7Ci 20 j by .XEAN �SE;1�1� '�IQ , who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign dEFFRYLYAO Cgnnisul * G6 2408 E*m November 1Z 2022 Baidd7lw1*F*IMww- OW-M CONTRACTOR The foregoing instrument was acknowledged before me this /5 dayof0ez7- 20 Jy by J&rw-, /lam mrir.t ' ,1;�;o is�ei onally know�o as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: YINET RODRIGUEZ Y IV MY COMMISSION #GG216024 EXPIRES: MAY 09, 2022 APPROVED Plans Examiner Structural Review as **************** Zoning Clerk (Revised02/24/2014) N� ���� �������� MUNICIPAL I���UXTY RECORD 10/21/2019 ARRAPAL NO.2020-6904721 PROCESS NO. M2020000641 FOLIO: 1121360000 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /FIRE ALARM REQUIRED INSPECTIONS INIT DATE FIRE 0004 FIRE ALARM 209 FIRE FINAL n~� CONTM&MIMADE MIAMI- MUNICIPAL INSPECTIl]N-RE�LEMENTS AND RECORD 10/21/2019 mnmrrTpm mO'P0P0-0�4721 FOLIO: 11213600000 '—'---��- �'-'---- -- -- JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /FIRE ALARM LEGAL 36 52 41 40 AC SE1/4 OF NE1/4 LESS E35FT & LESS APPLICATION TYPE ALTER INTERIOR 0 SOFT 1 UNITS 1 FLOORS OWNER NAME BARRY COLLEGE CONTRACTOR RYBB FIRE ALARM INC QUALIFIER RAMIREZ DALIEN PERMIT TYPE MUNICIPAL ELEC CATEGORIES 0004 MUNICIPAL FIRE ALARM DATE: 10/21/2019 PROCESS NUMBER: M2020000641 NEW *AMOUNT PAID 509. TOTALS FIRE 509.92 *UBS1 0000000.00 *UPMU 0000000.00 FIRE 23520 ALTERATIONS 121.80 FIRE 1 FIRE ALARM UP 117.70 FIRE 8 ALARM ACCP TE 282.00 FIRE 1 SRI PLAN REVI 223.82 UBS1 1 BLDG 7.5% UPF 1.88 UPMU 1 UPFRONT FEE F 25.00 10/21/2019 15:26 E318558 311910210052 TCPM9390 CENTRAL 509.92 �� , MUNICIPAL I�xJ#���k����@�gR��P��v���Y RECORD 10/21/2019 T3]�AL NO.2020-004721 PROCESS NO. M2020000641 FOLIO: 11213600000 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /FIRE ALARM REQUIRED INSPECTIONS FIRE 0004 FIRE ALARM 209 FIRE FINAL INIT DATE MUNICIPAL I��@�����}������G�����v����/� RECORD 10/21/2019. M���?���AL N0.2020-004721 PROCESS NO. M2020000641 FOLIO: 11213600000 JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /FIRE ALARM TO SCHEDULE A FIRE INSPECTION, PLEASE VISIT THE WEB AT WWW.MIAMIDADE.GOV/BUILDING OR WWW.MIAMIDADE.GOV/FIRE. YOU WILL NEED TO PROVIDE YOUR TEN DIGIT MUNICIPAL INSPECTION NUMBER AND INSPECTION TYPE. THE INSPECTION TYPE CAN BE FOUND ON YOUR INSPECTION REQUIREMENTS AND RECORDS CARD,, IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING AN INSPECTION, SCHEDULING A PRELIMINARY INSPECTION, OR LOAD BANK TEST INSPECTION, PLEASE CALL FIRE PREVENTION AT 786-331-4800. IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING A PLAN REVIEW, PLEASE CALL FIRE ENGINEERING AT (786) 315-2771. **BE ADVISED THIS IS NOT A PERMIT. PERMIT IS TO BE ISSUED BY YOUR CORRESPONDING MUNICIPAL BUILDING DEPARTMENT. VIAMORADE MUI I PAL iM4AM6DAL)jEC.0UKTYREC-ORD 10/21 /20 19 AM JOB SITE ADDRESS 11300 NE 2 AVE PROPOSED USE SCHOOL BUILDINGS /FIRE AL -ARM r TION TYPE. THE INSPECTION CAN JAE FOUND ON YOUR INSPEC CP F�,ITNSPECTION REQUIRIEMENTS PND RECOPE I . R D IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING AN INSPECTION, SCHEDULING A PRELIMINARY INSPECTION, OR 'LOAD BANK TEST INSPECTION, PLEASE CALL 'FIRE PREVENTION AT 786-33l -4800. IF YOU HAVE ANY QUEST]ONS OR CONCERNS REGARDING A PLAN REVIEW, PLEASE CALL FIRE ENGINEERING Al (786) 315-2771. � **BE ADVISED THIS IS NOT A PERMIT. PERMIT IS TO BE ISSUED BY YOUR CORRESPONDING MUNICIPAL BUILDING DEPARTMENT. �, / Miami -Dade Fire Resc Fire Alarm Pre -Submittal C i AMI•D�4L}E Based On NFPA 72 2010' Ed. & NFPA 1 and 1 1 2 Ed. Building Dept. Process Number is (Begins with C or M): A n 1 Project Name: BARRY UNIVERSITY NHS BUILDING Is vid d n o I ns. YES NO N/A 2 Address in title block shall match address in "Building Dept. Computer System" and attache i i n. If a I ss contains ❑ El specific building, floor, suite, or unit number or letter, it shall be provided in title block, to ma ui D t. Com ter System. 3 The total cost of the installation to the customer is $ 23530.00 and a copy of the contract or a notarized ❑ ❑ affidavit from the owner showing this amount is attached. 4 Fire Alarm Systems costing more than $5,000 are sealed or stamped by a Florida Registered Professional Engineer. ✓ 5 The total number of DEVICES and COMPONENTS being installed is $ 6 The alarm qualifier's state license number is (EC EF EH EY) # I EC13007228 and a copy is attached to plans. 7 Complete, current Manufacturer's Specification and Installation sheets are attached for all Control Units, Components, Appliances, Devices, Modules and Relays listed on Legend. 8 Is this permit application for fire alarm work a result of a Notice Of Violation (NOV) issued by Miami -Dade Fire Rescue? If yes, a copy of the Notice of Violation is attached.Tbi&f• • ' • • • • NFPA-101 40.3.4.3 ire alarm: is required under (fill in the Occupancy Chapter & Section fro4 NFPA 101) or9 �' • • • 9 is a life safety equivalency or, is a non -required system or component. ••:' • • • • ✓ • This is an "EXISTING (Local) Fire Alarm --System" and is stated as such on the plans. AHJ will require documental of prior • • • 10 approval of system as a (Local) Fire Alarm System in the form of the original Fire Dept. approved job copy set off re araim plar49. ' • � or, certified microfilm copy of same. • • • 11 This is a "NEW Local Fire Alarm System" and is stated as such on plans. ."• •. ✓. 12 This is an "EXISTING Central Station Service Fire Alarm System" and is stated as such on the Plans. A copy o tfie existing . ' BUILDING UL or ETL certificate or FM Placard, specifically identifying this protected premise by address and, r ".identifying • • "• • ' •n this building's fire alarms stem, is attached. • • • l___l 13 If the company that issued the existing certificate or placard for this building's fire alarm system is different tharathe company •.... applying for this permit; is the required Affidavit to Work on another Company's Certificated or Placarded Fire AWvft S:stem ❑ • •. Provided? • • This is a NEW Certificated or Placarded "Central Station Service Fire Alarm System" and stated as such on the lath... If this is a NEW "Central Sta Ion Service Fire A System," a copy of the UL or ETL certificate of FM placard from the contractor • • 14 ✓ ✓ 15 or, from the Central Station Service Company, issuingthe buildingcertificate/placard, is attached. 16 This is an "EXISTING Remote Supervising Station Fire Alarm System" and is stated as such on the plans. AHJ will require documentation of prior approval of system as a Remote Supervising Station Fire Alarm System in the form of the original Fire Dept. ❑ ❑ approved job copy set of fire alarm plans or, certified microfilm copy of same. 17 This is an "EXISTING "Sprinkler Waterflow and Supervisory System" only and is stated as such on plans. 18 This is a NEW "Sprinkler Waterflow and Supervisory System" only s stated asslT�� and provides emergency forces notification through a Certificated or Placarded 1 plans. The system is monitored off -site 1 "Central Station Service Fire Alarm" and is stated as such on the plans. IIIILL��_JJ L A complete detailed statement of the "SCOPE OF WORK" is stated on the plan. Please note that the complete tenant space, in its 19' entirety, will be inspected for compliance with NFPA 72 (2010) and NFPA 101 (2012), or prior editions of these codes if applicable. F Also outline scope of wDLLWith bolded dashed lines on floor plan and riser for existing systems. 20 The building is "New or, "Existin ✓ I and is indicated as such on the plans. ✓ 21 A description of the building is provided, including fire sprinkler systems, fire suppression systems, number of stories, square foots a per floor, and elevation of the last occupied floor if over 5 stories. 22 A location Key is provided showing the area of proposed work within the building. Also provided is a site key for projects with ✓ multiple buildings showinglocations of all buildings with addresses 23 All interconnected Fire Alarm Control Panels are arranged to function as a single system and monitored for integrity er NFPA 72. r 24 The Class is shown for all Initiating Device Circuits (IDC), Signal Line Circuits (SLC) and Notification Appliance Circuits (NAC). 25 The maximum number of each device type is provided for each IDC based on device load or each SLC, based on CLASS, per NFPA 72 and the manufacturer's specifications. 26 A specific "Sequence of Operation" including all alarm, supervisory, trouble and control functions such as fire sprinkler, door release, smoke control, elevator recall, suppression systems, and transmission of signals offsite, etc. are specified on the Dlan. 27 The type of monitoring station, (Listed Central Station, Remote Supervising Station, Listed Proprietary Supervising Station), where "Sequence ✓ alarm, trouble, and supervisory signals are transmitted to, is clearly and concisely stated in the of Operations" 28 The method of communication to the monitoring station is included on the riser. ✓ 29 If this building contains elevators that are not capable of recall, it shall be stated as such on plans and written documentation on ✓ elevator contractor's letterhead stating that "Elevators are not capable of providing recall function", is provided, 30 If this building does not contain a fire alarm system, and the fire alarm panel is used exclusively for elevator recall; plans shall ✓ clear) designated panel as "Elevator Recall Control and Supervisory Panel" 31 Manufacturer, model number and unique symbol for each model number is provided for each device, module, relay, component, power supply and fire alarm control panel is specified in the symbol legend. 32 Each device, module, appliance and component is identified with its own unique number and indicated on the floor plans and riser. 33 Floor plans are drawn to 1/8" scale or, if using another scale, all device coverage is diagrammed on the floor plan and all room ✓ dimensions are included. Designed by: Signature: Phone #: Created by: MDFR 01 / 2015 THIS IS A REQUIRED DOCUMENT ON ALL FIRE ALARM PLAN SUBMITTALS 1 OF 2 Miami -Dade Fire Rescue Fire Alarm Pre -Submittal Checklist Based On NFPA 72 2010' Ed. & NFPA 1 and 101 2012' Ed. oho, M, 34 All rooms & spaces are labeled indicating their use, and the occupant load has been provided for all assembly use rooms with an occupant load of 50 or greater. 35 All new, existing, replaced or relocated devices are indicated on the floor plans and a complete riser diagram showing all new and ✓ existing devices of the entire fire alarms stem is provided. 36 Ceiling Height, Type and Angle is provided for all ceiling mounted devices. ✓ 37 All devices and components located in areas in which the voltage, temperature, and humidity variations exceed those conditions stated in NFPA 72, are listed for conditions and all such areas are identified. 38 A note is provided on the plans stating "Room containing FACP, Booster Power Supply, Voice Evacuation and Amplifier panel(s), Dialer, or Radio is mechanical) ventilated", as applicable. 39 The FACP or Remote Annunciator and as applicable EVAC panel or Remote Microphone is located at the main entrance/lobby in single tenant buildings, or in a common area main entrance/lobby of a multi -tenant building. 40 The FACP, Communicators, Amplifiers, NAC Panels and all sub -panels are protected with a smoke detector. ✓ 41 If a complete automatically activated system, not less than one manual fire alarm pull box shall be provided to initiate system. The pull box shall be located where AHJ specifies. If a manually activated system, the travel distance to reach a pull station is less than 200' feet and within 5' feet of all required floor 42 and/or building exits. : • : • • All automatic initiating devices are shown and are located in accordance with NFPA 72, the manufacturer's specificmonsR and • • • • 43 accepted engineering ractices. • • 44 Area smoke detectors, if used, shall provide coverage throughout the entire smoke compartment. • .. •. • • • 45 All visual notification appliances are placed per tables in NFPA 72 and each strobe has its candela rating on the `eor0an and riser. �/ ; • • • 46 All corridor spaced strobes are placed a maximum of 100' feet apart and within 15' feet from the ends of the corridor•' • •• ✓ • • 47 Al[ spaces throughout the entire building shall meet the audible characteristics of NFPA 72 and NFPA 101. • • • • ✓ • • 48 arm Sighaf o Where audible appliances are provided to produce signals for sleeping areas, they shall produce a Low Frequ: ncy. • • • per NFPA 72.18.4.5.3. • + • 49 Bell used for water flow annunciation is shown on floor plan, riser and legend. Bell shall be located so as to be visible a17d heard • -/ from roadway or parking area within close proximity to Fire Dept. Connection (FDC). • • • • • • • • • • •' J� 50 Flow Bell sequence of operations shall state as follows: A) Flow bell shall activate upon water flow only. B) Flow bell silall corltinue •• • • • to sound as long as water is flowing. C FACP shall not be capable of silencing Flow Bell. + • 51 The location of Backflow Preventer (BFP) and Post Indicating Valve (PIV) are indicated on the floor plans, riser and legend for ' sprinkled buildings. Also, the location of the Fire Dept. Connection (FDC) is shown on floor plans. 52 Walls, partitions, racks, shelves and equipment that do not extend to ceiling, are shown with their heights indicated on floor plan. ✓ 53 Duct detectors or relays for duct detectors are shown on the floor plan and riser for all systems over 2000 CFM supply or 15,000 CFM return. Duct detectors shall derive their 24 vdc power source from the Fire Alarm System to satisfy the monitoring for integrity ❑ ❑ requirements of NFPA 72.10.17, for devices and conductors. Please show compliance on riser. 54 A complete system riser diagram is provided showing each floor of the building with all zones and circuits labeled. F 55 The conductor size, type, and quantity are provided for each circuit on riser. ✓ 56 The fire pump is monitored for: A) Pump or Motor Running, B) Loss of phase, C) Phase reversal. connected to an alternate source; and are indicated at a continuously manned location, or and, if applicable, D) Controller "the supervised fire alarm ❑ ❑ system. 57 Show all relays on floor plan and clarify function on riser. (Sprinkler, Wet Chem., Dry Chem., Clean Agent, Foam, A/C shut -down, Door Release, Elevator Shunt -Trip, Music Shut -Down, Smoke Control and other building control functions. 58 The AMPACITY of each Power Supply and Notification Appliance Circuit is specified for each FACP & Power Supply Panel on tans. In addition, the individual device current is specified on riser for each notification appliance(Horns / Speakers / Strobes). 59 The total "ACTUAL" footage to the last device along with voltage drop calculations are provided on plans for each NAC for each ✓ power supply. 60 The wattage tap is indicated for all speakers. ✓ 61 The wattage capacity and load is provided for each amplifier. ✓ All load values for "STANDBY" & "ALARM" used in calculations are high -lighted on the manufacturer's specification or installation 62 sheets. Also, AMPACITY of eauioment/comoonents and circuits are high -lighted on manufacturer's sheets. 63 This system includes Emergency Voice Evacuation and is provided with 15 minutes of secondary alarm power. Required in all high ✓ rises and assembly occupancies with an occupant load greater than 300. 64 This system is being provided back up power by an emergency generator and will provide 4 hours of standby power plus the ✓ appropriate seconds alarm power. Also, clarify120 volt panels feedingFire Alarm components, is connected to generator. 65 Battery calculations, detailed in chart form, showing all information required per NFPA 72.10.5.6.3.1 are provided on plans for each back-up power supply. The replacement of the Fire Alarm Control Panel with anything other than the exact same make and model number panel; or the 66 addition of a Fire Alarm Control Panel which will provide or replace any of the functions of the existing FACP, shall require the fire alarm system to be up -graded to current code standards, per code of Miami -Dade County, Part III, Chapter 14, Article III, Section 14669&10 67 If the scope of work includes greater than one-half of the entire fire alarm system's devices, then the entire fire alarm system shall ✓ be up -graded to current code standards, per code of Miami -Dade County, Part III, Chapter 14, Article III, Section 14-66 (9). Designed by: Signature: Phone #: Created by: MDFR 01 / 2015 THIS IS A REQUIRED DOCUMENT ON ALL FIRE ALARM PLAN SUBMITTALS 2OF2 Subcontract Agreement Thermal Concepts Inc. DBA Thermal ,2201 College Avenue Davie, FL 33317 Phone: 954-472-4465 Fax: 954-370-6410 WHATEVER IT TAKES Date: 07/01/2019 Project No: 2019.002. Subcontract No: 2019.0(d2.08'."'�' ••.... Project: Barry University Siena Building Contract No: 2019.OQ ... • 11300 NE 2nd Avenue ... •• % • Subcontractor: Rybb FireAtarm, Inc. • :••••; Miami, FL 33161 7311 Ngji;'west 1 A rdo� , Suita 27•. Miami,.F.L'.V126 •. • "' • • • Customer: Barry University • : • •: •: • 11300 NE 2nd Ave Sub Contact: Not Saecified :. •„• • ....:. Phone: •..• Miami Shores, FL 33161 Fax: ; �• •.;,. • ;.••.; ' Owner: Barry University Architect: TWR Engineers 11300 NE 2nd Avenue 12915 SW 132nd Street #1 Miami Shores, FL 33161 Miami, FL 33186 Contract Amount: $23,530.00 Thermal Concepts Inc., a Florida Corporation, (Thermal) and Rybb Fire Alarm, Inc., agree: 1. SUBCONTRACT DOCUMENTS - Subcontractor agrees to complete the Work in accordance with the Subcontract Documents which consist of (a) this Agreement; (b) the General Contract and all Contract Documents enumerated therein; and (c) all modifications to the General Contract and this Subcontract which are provided to the Subcontractor (collectively "the Subcontract Documents"). In addition to the aforesaid documents, the following additional documents are part of the Subcontract Documents: 2. SCHEDULE OF PAYMENTS - Contractor will pay Subcontractor for the proper and timely performance of this Subcontract Pay to the subcontractor shall be due when all preconditions to payment have been met by the subcontractor, included but no limited to, this subcontract agreement been signed, returned and approved, insurance certificate satisfying all requirements of Exhibit A and partial or final releases of lien; but in all events not sooner than the 10'" day of the next month following receipt of payment from the General Contractor to the Contractor. 3. INSURANCE - Subcontractor shall obtain and keep in force during the term of the subcontract insurance in accordance with the contract documents and this agreement, unless otherwise agreed in writing by Thermal. As a condition of payment for the work, Subcontractor shall furnish on a form acceptable to a certificate from each insurance company showing the required insurance to be in force and stating that the insurance will not be canceled or changed except upon at least thirty (30) days written notice to Thermal, prime contractor, and the Owner. Subcontractor insurance shall be primary and non-contributory. Thermal shall be named as an additional insured. General liability must provide products/completed operations coverage. Subcontractor shall maintain products -competed operations through the longer of the applicable statute of limitations or repose period for construction defects and products liability claims in the state where the work is performed. 4. TIME AND SCHEDULING WORK - Subcontractor shall commence work immediately upon execution of this agreement and shall schedule the Work such that Subcontractor will not interfere with the completion of work of other subcontractors or Contractor. The Work must be completed in accordance with the time provided for in the Subcontract Documents and failure to complete the Work by this date will subject Contractor actual damages or liquidated damages as provided for in the Subcontract Documents Working days are defined as Monday through Friday inclusive, holidays excluded. Scheduling of work, as provided for in this subcontract, is based on acceptable industry standards. Page 1 of 6 5. THIS AGREEMENT is subject to the terms and conditions of the Scope and as stated in Exhibit "A" & Exhibit "C 6. SOLE AGREEMENT - This Agreement, including all terms and conditions hereof, is expressly agreed to and constitutes the entire Agreement as of this date. No other Agreement or understandings, verbal or written, expressed or implied, are a part of this Agreement unless specified herein. IN WITNESS HEREOF the parties have accepted this Agreement the day and year first above written. Isaac Baez Digitally signed by Isaac Baez Pardo Pardo Date: 2019.06.2710:07:26 04'00' Rybb Fire Alarm, Inc. Signature Date . • •••••• Ve • •• •..•• Thermal Concepts Inc. Signature Date • ...... ...... IBP /_Initial Page 2 of 6 EXHIBIT "A" ATTACHMENT TO SUBCONTRACT AGREEMENT BETWEEN Thermal AND Rybb Fire Alarm, Inc. (vendor) PAGE 1 Subcontractor Shall: a) Provide written daily reports to Thermal foreman. b) Provide written schedule, to include manpower loading on a monthly basis for the duration of subcontract. • • • • c) Pay applications are due in our office the Friday before the 7th of each month projecting through the 25th;*a month. A detailed Scheddlr3'; • boos of Values is due within (10) working days after receipt of this subcontract. ,.,,. 0 • • • • • • '. o boob.. d) Subcontractor Purchase Order number and Project number must appear on all applications for payment. "' o • • . • e) Clean up on a daily basis and remove trash from jobsite weekly, to the satisfaction of Thermal. '.0 # 0 • : • so o ' 000 f) Provide adequate materials, equipment, manpower, etc. to keep pace with the construction schedule. ";' •; : •. .0 ..:. o' g) Attend jobsite meetings as required. b o o b.. 0 0 0 0.0 0" o , , h) Safety hard hats, hard shoes, and proper clothing at all times. • ' 0 • • 0 • .. 0, 0 • i) All site personnel must attend our weekly safety meetings. You will be required to participate in Thermal' on site sawpr4grams., . . :.000 j) All personnel must report to the Thermal office trailer daily to sign in and sign out when leaving the project. • • • • k) Furnish 12 copies of all submittal data literature and shop drawings. Process immediately and submit not later than two weeks after acceptance of this contract 1) Subcontractor to perform all tests required for subcontractor's scope of work as per the specifications. m) Thermal requires subcontractor to provide authorized, competent personnel for equipment start-up, test and balance, commissioning and any other time necessary to cooperate in finishing the project within the allotted time schedule. n) Furnish immediately upon request, a minimum of 6 copies of maintenance and operations manuals, certifications, parts lists and as-builts for subcontractor's work. Progress and/or final payments may be contingent upon proper and prompt response to this requirement. o) Coordinate its work with all other trades. p) Be responsible to ensure that all openings for the passage of its work through floors, walls, ceilings, roofs, etc. are property coordinated. Supervision for this work to be provided by subcontractor. q) Maintain the following minimum insurance requirements (or higher as may be required by the contract between Thermal Concepts Inc.. and the prime contractor or owner, and/or the contract documents). Comprehensive General Liability Insurance, including contractual liability: $1,000,000.00 per occurrence with $ 2,000,000.00 aggregate coverage. Onsite Automobile, truck, and all other equipment Liability insurance: $1,000,000.00 Worker's Compensation Insurance: $ 500,000.00 Employer Liability Insurance: $ 500,000.00 Umbrella Policy $1,000,000.00 EXHIBIT "A" IS A PART OF THIS AGREEMENT. IN THE EVENT OF CONFLICT BETWEEN ANY PART OF THE AGREEMENT AND THIS EXHIBIT, THE MORE STRINGENT REQUIREMENT SHALL TAKE PRECEDENCE. IBP /_ initial Page 3 of 6 EXHIBIT " C" ATTACHMENT TO SUBCONTRACT AGREEMENT BETWEEN Thermal AND Rybb Fire Alarm, Inc. (vendor) PAGE 1 SECTION I —ADDITIONAL INSURED Subcontractors of Thermal Concepts Inc. shall purchase and maintain during the entire project and during the warranty period, insurance with the minimum limits and coverage shown below or, if greater - the requirements set forth in the Contract Documents, from insurance companies acceptable to General Contractor. GENERAL LIABILITY Subcontractor shall carry standard ISO General Liability coverage, written on an occurrence basis - including Completed Oper4i9r1s.; Jhe coverage must be endorsed to name General Contractor as an "additional insured" (Form CG201011185 or equivalent -meaning thr: tdditionaltnsured coverage fora.. to include work in progress —i.e. all acts or omissions or any other liability of additional insured arising out of subcontraItar's Work pqlbtr O for additional* insureds or subcontractors us of premises, equipment and facilities of additional insureds - i.e. ongoing operations*dh%dbfhpleted v"O&i.e. Corn*Q&. Operations) and include the Owner, Architect and others as "additional insureds" as required in the contract documents. l'A'Addltional Insured" form shad state . that this insurance shall be primarywithout right of contribution from any other insurance available to the "additional insuW& ^� the arxoun t of the corr;JAR ? liability under this policy shall not be reduced by the existence of such other insurance. Copy of the additional insurecrdmersement;rm rsdo be attagljo. the Certificate of Insurance. A waiver of subrogation will be provided. ' •; • •; ..:..' .. .. . .. ...... SECTION II — FLORIDA INDEMNITY ' To the fullest extent permitted bylaw, the Subcontractor expressly agrees to indemnify and hold harmless the Contractof,e& project owner,1he architeet!arxf: the engineer and their respective officers, directors, agents, and employees herein called the "indemnitees" from any and all liability f&Agiips, including, if allowed by law, reasonable attomey's fees and court costs, such legal expenses to include costs incurred in establishing the indemnification and other rights agreed to in this Paragraph, to persons or property caused in whole or in part by any act, omission, or default by the Subcontractor or its sub - subcontractors, materialmen, or agents of any tier or their employees, arising out of this Agreement or its performance, including CI) any such damages caused in whole or in part by any act, omission, or default of any indemnitee, but specifically excluding any claims of, or damages against an indemnitee resulting from such indemnitee's gross negligence, or the willful, wanton or intentional misconduct of such indemnitee or for statutory violation or punitive damages except and to the extent the statutory violation or punitive damages are caused by or result from the acts or omissions of the Sub -contractor or its sub -subcontractors, materialmen, or agents of any tier or their respective employees. Provided however that any claim for indemnification for damages caused in whole or in part by any act, omission or default by indemnitee(s) shall be limited to the amount of Sub -contractor's insurance or $1 million per occurrence whichever is greater. The parties acknowledge that the amount of the indemnity required hereunder bears a reasonable commercial relationship to this Agreement and it part of the project specifcationsorthe bid documents. The indemnification obligations under this Agreement shall not be restricted in any way by any limitation on the amount or type of damages, compensation, or benefits payable by or for the Sub -contractor under workers' compensation acts, disability benefits acts, or other employee benefits acts, and shall extend to and include any actions brought by or in the name of any employee of the Sub -contractor or of any third party to whom Subcontractor may subcontract a part or all of the Work SECTION III — INSURANCE REQUIREMENTS The GL shall induce such coverage, but not limited to, premisesloperations, employees as insureds, explosion, collapse and underground (XCU), broad form contractual (including personal injury), productslcompleted operations, independent contractors, broad form property damage and personal injury. The CGL must be written on an occurrence basis, with minimum limits of: General Aggregate - Per Project $2,000,000 Products and Completed Operations Aggregate $2,000,000 Each Occurrence $1,000,000 Personal/Advertising Injury $1,000,000 Fire Damage $100,000 Medical Payments $10,000 COMPREHENSIVE AUTOMOBILE LIABILITY on occurrence basis covering all Owned, Non -Owned and Hired Vehicles for limits of liability equal to $1,000,000 Combined Single Limit. IBP /_ Initial Page 4 of 6 EXHIBIT " CI ATTACHMENT TO SUBCONTRACT AGREEMENT BETWEEN Thermal AND Rybb Fire Alarm, Inc. (vendor) PAGE 2 WORKER'S COMPENSATION including Occupations Disease insurance meeting the statutory requirements of the State in which work is to be performed together with a Broad Form All States Endorsement and containing Employer's Liability insurance in an amount of at least $500,000 Each Accident / $500,000 Disease -Policy Limit 1$500,000 Disease —Each Employee. Workers Compensation shall waive the rights of subrogation in favor of all additional insureds. • UMBRELLA LIABILITY and/or EXCESS LIABILITY with coverage at least as broad as the underlying policies. The par occurrence ar4aggregate limits • shall be $1,000,000. • • •; Y • • • • • .. •.:. A certificate of insurance form must be filed with Contractor prior to the commencement of any work and musto Sthtt• joverage will cot be algrM,% cancelled or. allowed to expire without thirty (30) days written notice by certified mail to Contractor. If any of the atdVLAcoveragas are, subject to.%ark. in excess of any deductibles or self -retention, these amounts must be stated on the certificate, and said deductibles ptd Self-retefl ion will be th64" • responsibility of Subcontractor. go' • *so . •.... It is understood and agreed that the insurance coverage and .limits, required above, shall not limit the extent of • • • •: • Subcontractor's responsibilities and liabilities specified within Contract Documents or by law. : .'. 0 • • • •• . . .. It is understood and agreed that authorization is hereby granted to refuse entry to job site and to withhold payments to ; • 0 • Subcontractor until a properly executed Certificate of Insurance is received by Contractor. Subcontractor's Insurance Requirements set forth herein shall become and be part of any purchase order or contract issued by Contractor to Subcontractor as though fully set forth in said purchase order or contract. Should Subcontractor fail or neglect to provide the required insurance, Contractor shall have the right, but not the duty, to provide such insurance and deduct from any money that may be due or become due to Subcontractor for any and all premium or costs Contractor incurs. Equivalent insurance coverage must be obtained from each Sub -subcontractor and Supplier, if any, before permitting them on the site of the project. Otherwise, such insurance for Sub -subcontractors and Suppliers must be included within Subcontractor's insurance policies. EXHIBIT "C" IS A PART OF THIS AGREEMENT. IN THE EVENT OF CONFLICT BETWEEN ANY PART OF THE AGREEMENT AND THIS EXHIBIT, THE MORE STRINGENT REQUIREMENT SHALL TAKE PRECEDENCE. IBP /_ Initial Page 5 of 6 Thermal Concepts Inc. a Florida Corporation, ("Thermal") and Subcontractor agree: DESCRIPTION OF WORK - Subcontractor agrees to furnish all labor, materials, drawings, samples, and necessary equipment to complete the following work including all work incidental thereto ("the Work"): The materials, products or services to be furnished in strict accordance with the terns, conditions and requirements of the Prime Contract documents including General and Special Provisions and Conditions, plans, specifications and addenda, which documents are incorporated by reference and made a part of this subcontract. A detailed list of documents is attached. The price of this subcontract is complete and includes all applicable federal, state and local taxes as well as all packing and shipping costs. This subcontract is contingent upon Engineer, Architect and Owner approval. This is the last page of the Subcontract agreement between .*00*0 Thermal Rybb Fire Alarm, Inc:..•': '.... "':*' and .00.0: • • • .... . ..... :0 : 0 0:0 0: ..:.. .. .. . •• ••.•.• ...... . .. . • . . •••••• . . • • • • • • .: . IBP /_ Initial Page 6 of 6 RYB13 Fire Alarms Inc. Excellent Service is our goal Miami Office 7311 NW 12"' St. Suite 27 Miami, FL 33126 Phone:305.903.2287 Email:rybbmanager@rybbfirealarm.com Web: www.rvbbfirealarm.com FM Approvals- Barry University -NHS Air Conditioner Replacement Proposal # 20181219-B-NHS • 1 eW FM Approvals- Ayeh'-?- F" C;/011t1/ Grc�rr/, Proposal # 20181219-B-NHS Billina Customer: THERMAL CONCEPTS, Inc. 2201 College Avenue Davie, Florida 33317 www.thermalconcepts.com December 18, 2018 Service Address: Barry University NHS 11300 NE 2od Ave. Miami Shores FL 33161 Service Company: • • • •••••• •••••• •• • ••••• TERM: Valid•fcrr 30 aaU%* ...... •••• Miami Office 7311 NW 12" St Ste 27 Miami FL 33126 Phone: 305.903.2287 Email: rvbbmanager(a).rybbfirealarm. corn Web: www.rvbbfiirealarm.com Facebook: httos://www.facebook.com/RYBB-Fire-Alarm-1088196611234437/ 2 --e- FM Approvals Member c f the F"M Cii«bcrl fiscyrrfa Proposal # 20181219-B-NHS Qty. Description Price ...... 4 4098-9756 DUCT SENSOR HOUSING-4-WIRE •• • •... • 4 4098-9858 SAMPLING TUBE 97" '••;•• �••••� ....:. 4 2098-9806 REMOTE TEST STATION ""•• 4 4098-9845 DUCT WEATHERPROOF ENCLOSURE ."". •• :"": 12 4090-9008 DUAL RELAY IAM, IDNET 1 LABOR TO INSTALL AND PROGRAM ••••" • 1 TECH LAB TECHNICAL LABOR •• �• •••••• 1 COMM LAB COMMISSIONING LABOR ••���� • 1 DSGN LAB DESIGN LABOR ••••.. 1 CAD LAB CAD LABOR ' 1 PLANS (SIGN AND SEAL) •• ' 1 PERMIT PROCESSING 1 FIRE ALARM INSPECTIONS $23530.00 3 FM Alporavalslw .1 errxhc�r- �:;�f'71atr f%"M Cilc�l.�csl C.>r�arrl> Proposal # 20181219-B-NHS Exceptions and/or Clarifications: • RYBB is not responsible for the design of this project. Additional devices may be deemed necessary and could result in additional cost. • Any AHJ required additional equipment or system upgrades are not included in this proposal and will come at an additional charge. 00, • • This proposal is based on plans dated November 9`h, 2018. " ' • • • • • • Please note this proposal does not include a new fire alarm panel. 0• • • • • Please note some panels at this site maybe no longer manufactured or supported parts may IM available but could be in limited supply, panel has limited physical space and points. Addittor aTDarts or a panel upgrade may be needed and will come at an additional cost to the customer. • : : • * ' • Any additional device required, will be quoted at an additional cost. • • • Please note the turnaround time for drawing is usually 4 to 6 weeks at a minimum. . • • • • 6 • 1f RYBB finds that program revision changes have been made that are not recorded in our:Jatdb4e, no %do we have any history of a service request or a copy of software changes that have been made, additional ; • • • • • charges may be inquired. • • This Quote doesn't include any additional mapnet or idnet card. if additional cards are needed this will • • come at an additional cost. Panel may not able to support any additional devices and may have to be upgraded at the customer's expense. • Please note no duct detector sampling tubes will be shipped until the customer verifies the correct size in writing. • Please note if panel is not in a mechanically ventilated location. Mechanical ventilation will be provided by customer or if the panel needs to be relocated to a mechanically ventilated location it will come at an additional charge to the customer for this work. -,low FM Aloprovalso t4einl�er c;f tfat.• F'M Crl �l�crl (it<.. ttj> Proposal # 20181219-B-NHS Terms and Conditions 1. Price cover only the material listed above. Any additional equipment shall be paid for by the Customer 2. Sales are subject to RYBB, INC. standard credit terms and conditions. • • 3. Payments: 50% deposit, 50% when installation is finished. (May Vary upon agreement between parts) • • • • • • • • • 4. All payments are due upon receipt of invoice. On balance more than 30 days old, it is agreed that a Finance Chargo sfi' V/. per month will be made. Should the service of an attorney be required to enforce any part of a credit agreement, or for the collection of a.Vjnquent account, it is ; • • • agreed that the Debtor will pay all costs of collection including attorney fees. • • V • • • ' • • • • •• •��•• 5. Equipment to become property of the Customer upon payment of Selling Price indicated above in full. • •: • •; • • • • • : • • • 6. Customer to provide dedicated 110-volt line and 2 telephone lines to the FACP. •' 7. The above price is valid for 120 days from date of quotation. • • • • 8. All alarm equipment is warranty for one full year. • • • ' 9. Local authorities may require additional devices. 10. Customer to supply building floor plans in CAD files. 11. In no event shall RYBB, Inc. be liable for any special, incidental, indirect, speculative, remote, consequential, punitive or exemplary damages, whether arising out of or as a result of breach of contract, warranty, tort (including negligence) arising from, relating to, or connected with the services, equipment, materials, or any goods provided hereunder. 12. Notwithstanding anything to the contrary herein, if a portion of the services involves the installation and/or maintenance of system associated with security and/or detection of and/or reduction of risk of loss associated with fire, RYBB, Inc. total liability arising out of or as a result of its' performance under this agreement shall not exceed the amount of this agreement 13. Third Party Indemnification. When Customer has persons, or the property of others on the premises, or the system extends to protect property or others, Customer agrees to and shall indemnify, defend and hold harmless RYBB, Inc. its employees and agent for and against all claims brought by parties other than the parties to this agreement. This provision shall apply to all claims regardless of cause, including RYBB, Inc. performance or failure to perform and including defects in products, design, installation, maintenance, operation or non -operation of the System, whether based upon negligence, active or passive, warranty, or strict or product liability on the part of RYBB, Inc. its employees or agents, but this provision shall not apply to claims for loss or damages solely and directly caused by an employee of RYBB, Inc. while on Customers premises. 14. Painting, patching and trenching if required not included. 15. Customer agrees to pay for any expenses incurred by RYBB, Inc. due to interruptions in the installation and work schedule of the fire alarm system proposed due to customers' inability to provide access to the project location and installation area as per approved plans and design. Expenses include but are not limited to expired permits, failure to attend scheduled appointments, non-payment according to schedule of payments and failure or refusal to authorize a change order and payment for additional work required by the authority having jurisdiction (AHJ). If additional work is required by AHJ and customer refuses to authorize such work within 30 days, RYBB fire Alarms, Inc. reserves the right to proceed with the work as required by AHJ to complete the installation and close the permit. If this should occur customer acknowledges that RYBB, Inc. will be legally entitle to such payment as outlined in the proposed change order. Customer understand that RYBB, Inc. may place a hold on any existing open permit related to the work described above due to the customer inability to provide access to the entire installation area as required. 16. Sales tax not included. 5 FM Aloorovalso ,1?r•rrxL>crr- i;f the l4`M C;>"!uf'.rrl C.irvu�: I_Imltatlon oT Llami Proposal # 20181219-B-NHS 1. In no event shall RYBB Fire Alarm, Inc. be liable for any special, incidental, indirect, speculative, remote, consequential, punitive or exemplary damages, whether arising out of or as a result of breach of contract, warranty, tort (including negligence) arising from, relating to, or connected with any services, equipment, materials, or any goods provided hereunder including but not limited to maintenance, installation and annual fire alarm inspections. It is understood and agreed by the parties hereto that RYBB Fire Alarm, Inc. is not an insurer or insurance, if any, covering personal injury and property loss or damage on customers premise shall be obtained by the Customer, that RYBB Fire Alarm, Inc. Being paid for the installation or maintenance including annual inspections of a system designed to reduce certain risks of loss and that the amounts being charged by the company are not sufficient to guarantee that no loss will occur; that R` "d%arm Inc. is not assuming any responsibility for any losses which may occur including incidental equipment malfunctions even if due to the c:mparjyt negligent performance or failure to perform any obligation under this agreement. • • • 000,0 •••••• • e 2. Notwithstanding anything to the contrary herein, if a portion of the services involves the installation and/or mainteoan ce%f system associated with of security and/or detection of and/or reduction of risk of loss associated with fire, RYBB Fire Alarm, Inc. total liability arising out of or as a resdlt of its' performance under this agreement shall not exceed the amount of this agreement. • • • • • 411 • • • •••• • • • e •e 3. Third Party Indemnification. When Customer has persons, or the property of others on the promises, or the sy5 tV1,,,e#t,9gV to protect property or others. Customeragrees to and shall indemnify, defend and hold harmless RYBB Fire Alarm, Inc. its employees and agents forend against all jlil'igrs ergught by parties other than the parties to this agreement This provision shall apply to all claims regardless of cause, including RMMB Rid Alarm, IM. perim. ance or failure to perform and including defects in products, design, installation, maintenance, operation or non -operation oftIW4* wn, whether baled upon negligence, active or passive, warranty, or strict or product liability on the part of RYBB Fire Alarm, Inc. its employees or ants. • • NOTES: This agreement does not cover any repair caused by reason of vandalism, Acts of God, power failure, installation of incompatible equipment, obsolete parts and improper operation procedure or by any other cause beyond the control of RYBB Fire Alarm Inc. No representation of any kind has been made by RYBB Fire Alarm, Inc. to its customer except as set forth herein and this document contains the entire agreement between the parties. 9 .� FM Approvals - Customer Acceptance: Customer Name: Address:, Proposal # 20181219-B-NHS •..... ...... City: State: Zip: Signature: Date: ...... Name and Title (Print): Date: SPECIAL NOTES: rA ...... • ..•. ...... ...... � ..... ��� • � �� �\ i���♦ '�. E 4 �•' • R���R♦ ��V� � • • •����• •s�:•. • • • � � • � �� f ����• •���• � � •• � • � • •• � � • • • � • � � • • � � � JONATHAN ZACHEM, SECRETARY EGULATION ELECTRICAL CC, TRACTORS14PP4SING BOARD Feature Make a • Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an IP receiver • Automatically switches to 2G autorr syster mobil+ C24 C • PTM { Monit, to cell corner • Comp That I'liffsarc.nr--ew included) }milts it Gard® i monitoring •r• • • .••.•• . • • .• ••.•,. _• • • • • • • • 0006 • • 009000 • . , , • 3G technology from DS&I -": ;0. •••• The 3G3070CF connects the alarm control panel to the HSPA network and reports alarm signals directly to a monitoring station receiver (Sur -Gard System I-IP/II/III/IW5). The 3G3070CF uses the HSPA network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID format. The 3G3070CF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 and 2013 Editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G3070CF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G3070CF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the HSPA network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the HSPA network to the monitoring station. In instances where the control panel does not support Contact ID, the 3G3070CF has inputs pre-set to transmit fire alarm, fire Specifications supervisory or system trouble. Dimensions ................... Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station Input Voltage ................. receiver (Sur -Gard® System VII/III/IV/5). Current Draw ................. Activating & initializing the unit Operating Environment Activating and initializing the 3G3070 can be done using Weight ........................... the automaAdetQrephoneactivition system (VRU), mobile 90 Af0rface or wet ser int$rUe provided by CONNECT 24. Ao special tggJ5 ate requir a6 • • ..... dli.+sting .. • • • • • �9_1��'JG30701n� ijDL listW l�der File S4019, Listing �Gide UOX •a $ole or bac1" communicator for ..... commercial Firp monitorimgt411ations. When used as �9"commur i c gtor under NFFIA72 2010 guidelines ,the 3G3070CF will Send itefaea&eat once every 97 •seconds ensitifig lat three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013 guidelines the 3G3070CF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G3070CF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G3070CF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. Ordering Information: 3G3070CF-USA ..... Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) 0 0 O CE N O O 0 0 co .................... 11-1/2" x 10" x 3„ (29.2 cm x 25.4 cm x 7.62 cm) ..................120 VAC .......................300 mA .............320 to 1200 F (00 to 480 C) .............................12.8 Ibs (5.8 kg) B.Simplex TrueAlarm Analog Sensing UL, ULC, CSFM Listed; Weatherproof Duct Housing MEA (NYC) Acceptance* Enclosure 4098-9845 Weatherproof duct housing enclosure for use with the following TrueAlarm addressable duct sensor housings (ordered separately): • 4098-9755, Standard Duct Sensor Housing • 4098-9756, Duct Sensor Housing with Relay Output Addressable duct sensor housing details: • Photoelectric sensor and exhaust tube are supplied • Sampling tube is ordered separately per duct size • Continuous communications actively monitors status of electronic circuits • Refer to Simplex data sheet S4098-0030 for additional duct sensor housing details Weatherproof duct housing enclosure features: r • Circulation of conditioned air from the air duct helps maintain the sensor housing at its rated temperature range • Nonmetallic material does not require painting • Captive cover screws • Intake and exhaust tubes for weatherproof duct housing enclosure are supplied • Internal mounting plate is removable to provide a convenient drilling template • Includes required gaskets • UL listed to Standard 268A • NEMA 4X rating Description Smoke detection system designs that require smoke detection monitoring of an HVAC duct that is exposed to environmental extremes must provide protection against the anticipated temperatures and total weather conditions. The 4098-9845 Weatherproof Duct Housing Enclosure provides for the circulation of conditioned air around the internally mounted addressable duct sensor housing to maintain the sensor housing at its rated temperature range and provide protection from ambient environmental extremes. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:245 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use — City of New York Department of Buildings — MEA35-93E. This product was not FM approved as of document revision date. Additional listings may be applicable, contact your local Simplex° product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. °Op pO ° • • • goes **goes • 00 s • • •gee e••gee egeogs . . .. e • L==goes . .• •osoe gooses .. g • • ..... of •• • •• sosege Side View of WeatherprooADucl I-Tousing.Enclpsure .... g 4098-9845 with Duct Tube Detail vd Cuta"y Showing e • Sensor Housing (refer t54vDe:wo foredetails) :sees eso .g•. •- Mff Us am (40984845 Weatherproof Duct Housing Enclosure) Air Velocity Range 300 to 4000 ft/min Refer to (linear ft/min) (91 to 1220 m/min) graph on page 4 for UL Listed External -40' to 158° F additional Temperature Range (-40° to 70° C) information UL Listed External Up to 100% RH Humidity Conditions NEMA Enclosure 4X Category Solid body and door, light gray, Construction PBT/PC blended plastic, UL94-5VA flammability rating, UV stabilized Dimensions 22-1/8" W x 15" H x 7-1/8" D (562 mm x 381 mm x 181 mm) Addressable Duct Sensor Housing 4098-9755/9756 UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range 32° to 122° F (0° to 50° C) Storage Temperature Range 0° to 140° F (-18° to 60° C) Humidity Range 10% to 90% RH, non -condensing S4098-0032-3 10/2011 • • NOTE: Refer to Installation Instructions 574-922 for additional information. Weatherproof Duct Housing Enclosure 4098-9845 Duct 6ensor Htri.f MO with • senior• Ordered atel) . 115„ •• 1381 mm3' '• .•.••. •••• 7-1/8" (181 mm Duct outline, shown for reference Weatherproof enclosure air intake tube, supplied Sensor housing sampling tube, ordered separately per duct size Sensor housing exhaust tube, I supplied with sensor housing Weatherproof enclosure a Gaskets at each housing exhaust tube, supplied entry point, supplied 2 S4098-0032-3 10/2011 Installation Reference, Front View Showing Preferred and Alternate Orientations NOTE: Refer to Installation Instructions 574-922 for additional information. Preferred Orientation 22 1/8" (562 mm ° Weatherproof housing • • •.•.•. o intake tube location • 9Kc( eptabl@ Ai4artical . • Mounting holes, • • Orientation • • • • i • four places ; • • • Sensor housing • • •� • • • • • intake tube location • •'• I, • ° • • • 15" �I l.__Y •••••• (381 mm) e I F • • . M` • • •- ••••i• 'F • 1� Sensor housing exhaust tube location LJL 0 Weatherproof housing ° ` Wiring entrance area exhaust tube location Use flexible conduit with weatherproof fittings (not supplied) and seal conduit entrance with 3M Weatherban sealant #606 or equal (not supplied) 3 S4098-0032-3 10/2011 Application Reference, Ambient Temperature vs. Recommended Airflow Graph, The graph shown below presents the results of controlled laboratory testing performed on a typical 4098-9845 Weatherproof Enclosure protecting an internally mounted duct sensor housing. The external ambient air temperature of the 4098-9845 Weatherproof Enclosure was varied throughout its UL listed operating temperature range. Temperatures were recorded - within the protected duct sensor housing with varying duct air velocities of air maintained between 68' and 74' F (20' to 23° C). This graph illustrates how an increase in the test airflow velocity allows the airflow through the weatherproof enclosure to maintain the duct sensor housing at its rated range as the ambient temperature of the weatherproof enclosure is varied throughout temperatures anticipated for exterior air duct locations. PLEASE NOTE that for typical external air duct applications, heating air would be hotter than 740 F and cooling air would be lower than 68' F, extending the acceptable airflow range accordingly. • '....'O L ...... ---- — _ a- CL • . .. •0 .. .. ...... 0:0900 r60° C1 • 4 "• •:a 122° E ( 50° C) Recommended airflow range with duct air temperature between 680 to 740 F (200 to 230 C) 32* C ( 0° C) W d L 00 O (-18°C) v c W o -20° o (-290 C) CL � 1 -40° (-40° C) 300 450 600 750 900 1050- 1200 (91) (137) (183) (229) (274) (320) (366) Recommended Duct Air Velocity, Linear ft/min (m/min) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorked use is strictly prohibited. Weatherban and 3M are trademarks of the Minnesota Mining and Manufacturing company (3M). ®S i m p I =X Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4098-0032-3 10/2011 www.simplexgtinnell.com 02011 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdormnent revision date and are subject to change without notice. 9i®Simplex TrueA/arm Analog Sensing UL, ULC, CSFM Listed, FM Approved, Addressable Duct Sensor Housings with TrueAlarm II EA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNet or MAPNET II, 2-wire communications • Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: • Basic duct sensor housing (no relay output) powered by IDNet/MAPNET II communications Model 4098-9756: • Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control • At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: • UL listed to Standard 268A • Clear cover allows visual inspection • Test ports provide functional smoke testing access with cover in place • Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter • Magnetic test feature for alarm initiation at housing • Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): • Red Alarm/Trouble LED for sensor status and communications polling display • Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): • Available in multiple lengths to match duct size • Installed and serviced with housing in place Remote module options (ordered separately): • Remote red status/alarm LED (2098-9808) • Remote test station with LED (2098-9806) • 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. Accepted for use — City of New York Department of Buildings — MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. • Duct Sensor Housing, Front aGdgbttom Vie% • •.• o o ••• •• • r m • •m 2098-9808 2098-9806• . • • • Remote Status/Alarm Indicator and Test Station ,nductia Operation. Simplex compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. III CU IWWI F I I I I R111MOVINTMET• Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. [areas se note that smoke detection in air ducts is intended to provide ication of the presence of smoke in the duct. It is not intended nd will not, replace smoke detection requirements for open or other non -duct applications. S4098-0030-10 11/2014 • ••- • -• Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) .. .•TrueAlarmpVtoelectric�TeillSQV use a stable, pulsed • • •infrared LED•light source•a.silicon photodi ode • •receiver to provide consisje" and accurate low power • smo•ke sensing! • • • • � Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. Fire Alarm Control • Individual smoke sensitivity selection • Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements • Peak value logging allows accurate analysis for sensitivity selection • Automatic, once per minute individual sensor calibration check verifies sensor integrity • Automatic environmental compensation • Smoke sensitivity is displayed in percent per foot • Ability to display and print detailed sensor information in plain English language • ...... • Relays of model 4096-9756 are under panel control ..... . .. • for ON, OFF, or override .:.otrct SmuIL%;pnsor•Houstng with Photoelectric Sensor* • Model Descripti•n • • Compatibility •••+• •• •Basic Duct Sensor Housing; operating power is supplied by 4007ES, 4008, 4010, 4010ES, 4020, 4100, 4100ES, • 4098-97550 *dither IDNet or MAPNET II communications (no relay 4100E, and 4120. Also 2120 CDT if configured for output) MAPNET ll, TrueAlarm operation `Same as above except relay operation is not) Duct Sensor Housing with supervised multiple relay output,) 'compatible with 2120 CDT;, 4098-9756 Crequires separate 24 VDC fire alarm power and 4081-9008', ) (end -of -line resistor harness; includes one 4098-9843 relay; Relay output is for up to 15 total 4098 9843 Relays, —-------- - -- - - - (additional relays are ordered separately); Remote LED Indicator and Test Station, Select One if Required Model Description 2098-9808 Red LED status indicator on single -gang stainless steel plate Test Station with keyswitch and red LED status indicator, on r2098-9806) single -gang stainless steel plate; (turning switch to "TEST") tinitiates alarm for system testing)) Epoxy Encapsulated Remote Relay and End -of -Line Resistor Model Description 4098-9843) Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 additional relay information; one included with 4098-9756;1 Efor -- (wiring is 18 AWG (0.82 mm2) color coded wire leads( Compatibility Mounting 4098-9755 ,Uses single gang box,, (4098-9755 3" H x 2" W x 2" D� (mm x 51 mm x 51 mm) Compatibility U09&9756 only (connect up to 151 End -of -Fine Resistor Harness; 10 K2, 1/2 W; (ref. 733-894) 4081-9008) �reauired to suaervise remote relav coil connections— 14098-9756, Location ocate relays within 3 '(1 m) of device being ontrolled per NFPA 7; At last relay locationi * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. • • •- • • •-IIl-• •. • • Suggested Cut Length 1/2" (12.7 mm) longer than duct width Overall Duct Width 12" (305 mm) Tube Required 4098-9854 13" to 23" (330 mm to 584 mm) 4098-9855 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 4098-9856 3 in" (76 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 4098-9857 3 in" (76 mm) longer than duct width (71" to 95" (1803 mm to 2413 mm)) (4098-9858) (3 in" (76 mm) longer than duct width S4098-0030-10 11/2014 1 Neff R • • • NOTE: Refer to Installation Instructions 574-776 for additional installation detail and maintenance information. 11-3/8" (289 mm)�v Exhaust tube access hole ®lilt e X 4098-9714 Smoke sensor, mounted in special interface base (supplied) 6-3/4" (171 mm) • Sampling tube access hole X Stationary baffle (built-in) Captive fastening screws (4) Transparent cover Gasketed 3-3/8" (86 mm) sensor 11 mm 17 (21 mm) Exhaust tube (supplied) Test ports (2) provided Sampling tube, ordered for measuring airflow separately per duct width Gaskets (su and for aerosol injection r _ Alternate location (jf aparopriate) ----\�------------ DO NOT MOUNT ON BOTTOM OF DUCT -tal plate with dual holes 314" (19 mm) conduit, plug pplied for unused hole LED, relay control trouble I ;� 11 0 l: ] L f03" _3 L o a l0 A Red sensor � • • • • • 001 status LED Sidi of duct •••• • Wiring terminals • • • i • • • • • • •••• • • NOTE: Orientation shown is4or9aierence • • • • only, refer to General Loc4"l`Jq4es and • • End View illustration below for•alter*ate • • mounting reference. • • • • • • • • 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 1-3/16" � (30 mm) 1-1/2" 13/16" (38 mm) �(21 mm) 3 S4098-0030-10 11/2014 Duct Sensor Location Reference Exhaust .— Fresh air /Exhaust Damper ,Sensor OK 1 I —Return Air Do not locate sensor here Return air damper Supply Air J, n /-. Do not locate Filter bank Sensor OK sensor here • Duct Sensor Location Considerations: 1. Proper duct smoke detection location must ensure adequate airflow within the duct housing. 2. Duct air velocity rating is 300 to 4000 ft/min (91 to 1220 m/min). Pressure differential between intake and exhaust tubes is required to be between 0.015 to 1.55 inches of water (0.381 to 39.37 mm). 3. Ensure accessibility for test and service. 4. Proper Locations: downstream side of filters to detect fires in the filters; in return ducts, ahead of mixing areas; upstream of air humidifier and cooling coil. 5. Other locations and orientations may be required for proper duct smoke detection depending on duct access, system design, and duct airflow testing. Contact your local Simplex product supplier for assistance. •I•••f •' •Additional4nformation Refer to NFPA 90A, Standard I. Where dampersations to closedfor comfort control would •:•,,foirdheInstaiMlien ofAile0c:fb ttoningand Ventilating interfere with airflow. • •Sysiems; NFPA 72, the N*P4,1 1QFire Alarm and Signaling 2. Next to outside air inlets (unless the intent is to . t83e; and t1be N-9KA Guiaie fs»Proper Use of Smoke monitor smoke entry from that area). ..Qlige-ctors ineQuct:4pplicatiompand Installation Instructions 3. In return air damper branch ducts and mixing areas • • •V.4,776. . ..: :": •' where airflow may be restricted. .;:feral Mechanical and Environmental it Velocity Ra?ige (line%r ft/rryn) 300 to 4000 ft/min (91 to 1220 m/min) 1Sensor.S'1 %iti:ity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Liste emperature Range 32' F to 100° F (0' C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140' F (-18° C to 600 C) Humidity Range 10% to 95% RH, non -condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 MM2 to 3.31 mm2 ) Housing Color and Material Black ABS base with clear polycarbonate cover Sampling and Exhaust Tube Material Black CPVC, custom extrusion; sampling tubes are pre -drilled Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current f3.3 mA, no impact to 24 VDC alarm current (2098-9806)1 Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto -select, one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current (3 mA @ 24 VDC) (Alarm Currents k15 mA @ 24 VDC; add 15 mA for each 4098-9843 relay) Supervised Remote Relay Control Output For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kQ, 1/2 W end -of -line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current i 15 mA @ 24 VDC, up to 15 maximum per relay control output' Relay Contacts 7 A at 0.35 PF @ 28 VDC & 120 VAC; 250 i A @ 5 VDC Location Distance 500 ft (152 m) maximum to relay coils; locate relays within 3 ft (1 m) of device being controlled per NFPA 72 TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). I®S i m plex Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4098-0030-10 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. .... ....... ij� `Ti�7►11: TO ALARM SIGNALS UNLESS SYSTEM IS SET ON TEST DIALING 305-238-0800 :6 PROTECTED PROPERTY 0 6 • NAME: BARRY UNIVERSITY NHS BUILDING • ADDRESS: 11300 NE 2nd Ave. .... .. CITY: Miami Shores • • • • • • • STATE: FL ZIP CODE: 33161 SUPERVISING (CENTRAL) STATION: _CENTRAL ALARM CONZRM (CAr-) •..• TELEPHONE NUMBER: 305-238-0800 CENTRAL STATION SERVICE PLACARD This fire protection signaling system installation, all equipment and wiring plus the maintenance, testing and supervision thereof are in accordance with the central station Approval requirements of FM Approval Standard No. 3011. PLACARD IDENTIFICATION: ISSUE/REVISED DATE: EXPIRATION DATE: 170601034 09/01/2019 08/31/2020 PRIME CONTRACTOR: RYBB FIRE ALARM, INC. LICENSE:EC13007228 Tel: 305-903-2287 7311 NW 12th ST Suite 27 Name 7311 NW 12th ST. Suite 27 Address MIAMI FL 33126 City, State, Zip This is a New Placard Registration. Placard Registration Request & Fire Alarm System Data Sheet fM A0010uals Instructions: Upon. receipt of the Properly executed Placard Registration Request with: Copy of the actual Serialized Placard, Copy of the FMApproval Certificate from the prime contracting company and Copy of the Manufacturers Specification Sheets for the Fire Alarm system or components covered by the Placard, FM Approvals will begin. the process of adding the Protected Property described herein to our data base of Registered Placards. The prime contractor controls and bears all responsibility associated with each Placard. Registering Central Station Company or Local Installer — The Registering prime contractor acknowledges that the Fire Alarm System as described within this application will be installed and maintained in accordance with FM Approvals Standard 3011 requirements. Prime Contractor Authorized Representative of Prime Contractor ; • • • RYBB FIRE ALARM INC Isaac Baez Pardo •••• • •••• Name (Typed or Printed) Digitally signed by Isaac B.- Isaac Baez Pardo Pardo bale. 2019.09.11 19'2619 -04'00' Signature 09/11 /2019 Date 0 This is a Renewal of an Existing Placarded Registratttfi. • • . •••• Note - The Expiration Date of this Placard Registration is shown on the accompanying Central Station Company Certificate. LIMITATION OF LIABILITY — FM Approvals makes no guarantees or warranties, expressed or implied, that the Alarm System as installed will prevent loss by smoke, fire, water damage or otherwise. By signing this Registration Request, the applicant is agreeing to have this system be part of the FM Approvals Central Station follow-up audit program and indicated publicly. FM Approvals conducts inspections of the Registering Central Station or Local Company and sample installations made by it. FM Approvals does not assume, undertake or discharge any liability of the Central Station Company Registering the Placard. FM Approvals does not insure or accept any responsibility and assumes no liability which may result directly or indirectly from inspection of the equipment, failure of the equipment, failure to conduct inspections, incorrect Placarding, nonconformity or failure to discover nonconformity pertaining to requirements or expectations. The undersigned as an authorized representative of the installation or Protected Property named herein, acknowledges heishe has read and agrees on behalf of the Protected Property to the terms and conditions of this request. Protected Property Authorized Representative of Protected Property BARRY UNIVERSITY Jeffrey Yao Facility Name NHS BUILDING Name (Typed or Printed) Address Signature 11300 NE 2nd Ave. Miami Shor4 09/11/2019 City, State, Zip Date FM Approvals — Placard Registration Office Page I of 5 1151 Boston — Providence Turnpike Norwood, MA 02062 (Rev. 3/2003) Placard Registration Request & Fire Alarm System Data Sheet 1— FM Approved Monitoring Company and Location. Central Alarm Control, Inc. Company Name 13973 SW 140 St Address Miami, FL 33186 City, State, Zip Regina Brown Contact Name FACP Communication to Central Supervising Station is via; CIMpprouals Type Description (mfg/model info) """ McCulloh ❑ Dual line DACR ❑ ...:.. • Derived Channel ❑ • • • • .. Multiplex ❑ • 2-Way Radio 9( DSC3070CF """ • 1-Way Private Radio ❑ ...... Central Supervising Station Re -Transmission to Fire Department is via; Code Transmitter ❑ Direct Telephone Line ❑ Public Telephone Network V Private Network ❑ 911. Call Center ❑ Cellular Fire Department to be notified Miami -Shores Fire Rescue Department Fire Department Address City, State, Zip 2 - Fire Alarm Control Information Description (Mfg/Model) Simolex 4020-8001 FM Approvals — Placard Registration Office 1151 Boston — Providence Turnpike Nonvood, MA 02062 Contact Name Page 2 of 5 (Rev. 3/2003) ••.••• :0*00: •••.• • . • • • • :000*: Placard Registration Request & Fire Alarm System Data Sheet Note — Any deviations in equipment must be explained in comments sections. 3 - Automatic Detection fM approvals A Total — All areas, rooms or spaces are protected in accordance with NFPA 72. o Selected Areas Only — Same as above but only provided for specified area(s) as described in comments section o Partial — Protected area is provided with some detection coverage, but less than required in. NFPA 72. More information is provided in the comments section. Fill in the device counts covered by this Placard below. :. : • • • Type Qty Description (mfg/model info) •..... .... • ...... Smoke Detectors 85 2098-9652, 2098-9201 • • • : • • Duct Detectors 7 2098-9645, 2098-9201, 2098-9811, 209a-VtV7. : •, • Heat Detectors 0 • • • Flame Detectors 0 ••'••' : '..' .... Other 0 .. • . . . ...... Note — Any deviations in protected area coverage serviced by detection devices must be:explamed, m : • • • •: comments sections. • • • • 4 - Sprinkler System and Supervisory Device Operation o Wet Pipe System Type of Device Waterflow Sprinkler Supv. Water Pressure Water Temp. Water Level Air Pressure Fire Pump Power Fire Pump Running Other rNA ,of 0 0 0 0 0 0 0 0 o Dry Pipe System Description (mfg/model info) Note - If sprinkler waterflow and supervision is not provided on any installed sprinkler system, it must be explain in comments section. FM Approvals — Placard Registration Office 1151 Boston —Providence Turnpike Nonvood, MA 02062 Page 3 of 5 (Rev. 3/2003) Placard Registration Request & Fire Alarm System Data Sheet 5 - Manual Fire Alarm and Guards Tour Supervisory Service Type of Device Qty Manual Stations 18 Guard Tour Stations 0 Other 0 Description (mfg/model info) 2099-9795. 2099-9813 CIMpprouals Note — Any deviations in protected area coverage serviced by manual alarm stations must be explained in comments sections. 6 - Fire Alarm Notification Devices • • •; • • • • • • ....:. General Alarm System [3 Zoned or Selective Alarm Notification .... • • • ...... • • • ; • • Type of Device Qty Description (mfg/model info) • • • • • • • • • ... Bells 0 •••••• • Horns 0 • •••••• ...... Visual 0 • • .. • A/V Combination 32 2901-9840, 4903-9501, 4904-9105 • • • • Other 0 Note — Any deviations in protected area coverage serviced by Notification appliances must be explained in comments sections. 7 - Emergency Voice Alarm Service Type of Device Qty Voice/Alarm Channels 0 Speaker Zones 0 Speakers 0 Fire Fighter Phones 0 Phone Jacks 0 Other 0 Description (mfg/model info) Note — Any deviations in protected area coverage serviced by Notification appliances must be explained in comments sections. FM Approvals — Placard Registration Office 1151 Boston — Providence Turnpike Nonvood, MA 02062 Page 4 of 5 (Rev. 3/2003) Placard Registration Request & Fire Alarm System Data Sheet CIMpprouals 8,— System Maintenance and Runner Service - As indicated in this document, the Fire Alarm Signaling System and components are maintained in compliance with FM Approval Standard 3011. Service area within 4-hrs and equipment requiring manual Alarm reset within 1 hr. Provided by RYBB FIRE ALARM Inc. Isaac Baez Pardo Company Name Contact Name 7311 NW 12th ST. Suite 27 Address Miami, FL 33126 • • City, State, Zip •00. 0000406 .••..• • •..• 0000 Note —Any deviations in response time must be explained in comments sections.• •.000 0 .00000 .�T0 .... • •• 00 9 — System Test & Inspection - As indicated in this document, the Fire Alarm Sig�mg Syslorifand components are Tested and Inspected in compliance with FM Approval Standarq9W.1.. • Provided by RYBB FIRE ALARM Inc. Company Name 7311 NW 12th ST. Suite 27 Address Miami. FL 33126 City, State, Zip Isaac Baez Pardo Contact Name Note — Any deviations in system test & inspection must be explained in comments sections. 10 — Comments/Deviations from Referenced Standards (Attach Additional Sheets if required) FM Approvals — Placard Registration Office Page 5 of 5 1151 Boston —Providence Turnpike Norwood, MA 02062 (Rev. 3/2003)