EL-19-2582Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
Issue Date: 01/13/2020
Parcel Number
9290 N BAYSHORE DR, Miami Shores, FL 33138 1132050270240
Contacts
Permit NO.: EL-10-19-2582
Permit Type: Electrical - Residential
Work Classification: Generator
Permit Status: Approved
Expiration: 07/13/2020
RICKI LEE LONDON Owner
9290 N BAYSHORE DR, MIAMI SHORES, FL 331382949
GENERATOR SUPERCENTER OF Contractor
BROWARD
MIGUEL TOSAR
3800 N 28 TER, HOLLYWOD, FL 33020
Business:3059005055 carlo@conkretaconstruction.com
Inspection Requests:
Description: INSTALL NEW 38 KW GENERATOR Valuation: $ 15,000.00 Inspe tion R9
TotalSq Feet: 0.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$9.00
DBPR Fee
$7.88
DCA Fee
$5.25
Education Surcharge
$3.00
Permit Fee
$475.00
Scanning Fee
$9.00
Technology Fee
$13.13
Total:
$572.26
Payments
Date Paid Amt Paid
Total Fees
$572.26
Credit Card
10/29/2019 $50.00
Credit Card
01/13/2020 $522.26
Amount Due:
$0.00
Building Department Copy
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit 1 assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating construction n vo
Futhermore, I authorize the above named contractor to do the work stated. J))-3 2c
re: Owner / Applicant / Contractor / Agent Date
January 13, 2020 Page 2 of 2
ADVANTAGE GAS SERVICES
16891 SW 139 PL.
MIAMI FL. 33177
PHONE: 305-979-8281
LPGX LIC: 42062
Master Permit Number: L /0 ✓'q 2-09 "
Plumbing Permit Number: PL / nID \���
Job Site Address: '12 q a �S��IS�-•off `y� _ r"� r P M1 S FIOPJC3
Date & Time of Test: 3 117, 2 0
Natural Gas: _,L4'�Liquid Propane:
Starting Time: L ' eo3—
Ending Time: L , 30 1,-.
Manometer Test: Water Column Open Side, + 5 , and Lock Side, - 5.
Test Details: The drop test was measured with a manometer of water column, "U",
showing not variation and held the same differential for the time of test.
State License: L142062
Daniel Santana
Signature:
Miami Shores Village RECEIVED
g oLI9ors
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY:
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949 (b
BUILDING
PERMIT AP P ICATION
r-IBUILDING ELECTRIC ❑ ROOFING
FBC 20 (-
Master Permit No. 1_:7L— 0 j Gl' 2J
Sub Permit No.
❑ REVISION ❑ EXTENSION [:]RENEWAL
❑ PLUMBING [--]MECHANICAL [:]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
, hh ( CONTRACTOR DRAWINGS
JOB ADDRESS: `�'((��b ei;� N 1Mh&Y-e Q t-
/
City: Miami Shoorre�-s-� Coun : Miami Dade Zip:
Folio/Parcel#: -'�-�" �� "— Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type:�q�(� Flood Zone: BFE�: n FFE:
OWNER: Name (Fee SSi��`m�� ple T�itlleholddeer),:VA130 �(��,A�}� � Phone#:
Address:Q�`/ 1��yC�_X_�\ �D(
City:W\V�� '1 � L J T Stater Zip:
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name:U--` IlJ`
Address:�1 l
City: \, State:
Qualifier Name: Q0
State Certification or Registration #:�
DESIGNER: Architect/Engineer:
ne#:
Certificate of Competency #: _
Phone#:
Address: City:
Value of Work for this Permit: $ ' �� Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace
Description of Work:
Specify color
of color thru tile:
Submittal Fee $ DU, QZ) Permit Fee $
Scanning Fee $
Technology Fee $_
Structural Reviews $
Radon Fee $
Training/Education Fee $
Zip:
❑ Demolition
CCF $ CO/CC $ -
DBPR $ Notary $,
Double Fee $
Bond $
TOTAL FEE NOW DUE $ '32.. 2 • Z.6
(Revised02/24/2014)
r
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zi
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature I�l J� �•l� 1�� Signature
OWNER or AGENT C TRACTOR
The foregoing instrument was acknowledged before me this The fq�egoing instrument Was cknowledged before me this
_e day of (��iZ �� _. 20 h by �,� d y of OU _ 1Q , by
�k� It J6A.� . who i r_e sonally k � ` R ) � who is personal) own to
me or who has produced as me or who has produced as
identification and who did take an oath. identification and who Zoa
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign:
Print: y Print:
:. ••,': MY COMMISSION
Seal:
E EXPIRES: 1S, 2020 Seal:
3xded 7brU NftV �4ftn �u+'� NoataI State of Flor da
;P � Carl Cavallo
My mmission GG 323605
*********************************************************************** ***R4Kk****xres06'6130/2023 ******** ****
APPROVED BY ^� 1� /��� Plans Examiner \ �l ` Zoning
(�/ n Clerk
(Revised02/24/2014) a(�J
Summary Report
Property Information
Folio:
11-3205-027-0240
Property Address:
9290 N BAYSHORE DR
Miami Shores, FL 33138-2949
Owner
RICKI LEE LONDON
Mailing Address
1066 NE 94 ST
MIAMI SHORES, FL 33138 USA
PA Primary Zone
1400 SGL FAMILY - 3001-3250 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
3/4/1
Floors
1
Living Units
1
Actual Area
3,910 Sq.Ft
Living Area
3,302 Sq.Ft
Adjusted Area
3,446 Sq.Ft
Lot Size
10,937.5 Sq.Ft
Year Built
Multiple (See Building Info.)
Assessment Information
Year
2019
2018
2017
Land Value
$413,875
$393,750
$393,750
Building Value
$310,140
$314,448
$249,029
XF Value
$12,170
$12,280
$0
Market Value
1 $736,185
$720,478
$642,779
Assessed Value
$736,185
$720,478
$642,779
----------------
Benefits Information
Benefit Type 2019 2018 2017
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description
BAY LURE PB 44-63
LOT 12 BLK 2
LOT SIZE 87.500 X 125
OR 18113-3675 0598 1
Generated On : 9/30/2019
Taxable Value Information
2019
2018
2017
---------------
County
Exemption Value
$0
$0
$0
Taxable Value
$736,185
$720,478
$642,779
School Board
Exemption Value
$0
$0
$0
Taxable Value
1 $736,185
$720,478
$642,779
C ity
Exemption Value
$0
$0
$0
Taxable Value
$736,185
$720,4781
$642,779
Regional
Exemption Value
$0
$0
$0
Taxable Value
$736,185
$720,478
$642,779
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
04/24/2014
$716,0001
29128-4404
Qual by exam of deed
05/01/1998
$212,000
18113-3675
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version
_LCG I KICAL REV%�
I °s. �fz;
z APPROVEO�T` DATE
T J �
Q w
N F.I. 314" w o NO ! ` j
Ng -GA/
GA u 87.50' — NO 0
0.30'JL. t' E .F. 5.27 5,10 ao ' 4.69
co Zr) 12
v W
i T z � 25.00'
...,
4.9>
25.80'
Arc
S�a9
ODC4NC
. ?FtVE
a.35Q -� 26.30' �'/�•
o
7 i Q
LLJ
C � 4.95
%- a
L ZUw
6.43.'' U I '•` vt
ONE STORY 'Z► a
LOT - 13 RES. # 9290 4.92 °+
BLOCK - 2 ' LOT- f2
'J
M BLVCx .2 2.30 vi
X ry�o 4.92'.
Q� ' N
p C.5.: F..F.E.=7.83, 5.40' *,
ti s.2s '
W �--- L.F.E.=7 31'
GARAGE ELiwV.=5.72' •
•
POOL ' 27.302 .00' • • ��• i • • • i
PUMP •. • • •
0.40'CL.
�""" C� • i "• • i • • • • •
10.5 24.70' °� 475 ••JJJ• • • • �••'
�aKd
•
482 c�v • • • • •• •••
Y'S
% �, �� .�•
F.1 P 3i4`" . � B.C:. I--.�0 87.50 �Q . F.N.
NEW 38 KW OR
45','•P WY
OVER CONCRAT $ Rs26.00`
;7- 3 NGVD. AN r L-38.27'
10 FT FROM TS, Tan■25.00'
DOORS, W, A*90*00V0,,'
E��Y�NORE 4.� DRIVE OPENINGS FRUSTSIDE. SCREETHSHRUBS OR FOM 18' PvmASPf . LT
PVM'T.O STREET
Project: LONDON RICKI, 9290 N BAYSHORE DR. MIAMI GENERATOR SUPERCENTER OF BROWARD
SHORES FL. 33138 3800 NORTH 28TH TERRACE
Date: 10/21/19 Appn2os
HOLLYWOOD FL. 33020
Scale: N.T.S PHONE: 305-900-5055 EXT. 4
Drawn By: C.C. I LICENSE: EC13008869
NOT A SEPARATELY
DERIVED SYSTEM
EXISTING
OVERHEAD FPL
FEEDER
2- RIGID
3#2/0 Cu,
ONE LINE ELECTRICAL DIAGRAM
ELECTR►CgL REVIEW
APPROVE
DATE
ALL LABELS WILL BE
PLACED BY THE TIME
OF FINAL
INSPECTION
DIST. PANEL
EXISTING
NEW ATS
E.M.
MAIN
2.00 AMPS RATED
EXISTING TO
REMAIN
0
1 OF 1
FROM MAIN 1 OF 1
FROM ATS
200 AMPS
2" PVC
2" PVC
DIST. PANEL
OCPD
3# 2/0 Cu
NQT A MAIN
3# 2/0 Cu
1# 6 Cu
1# 6 Cu
22KAIC
22KAIC
225 AMPS RATED
1 I.B.T. I
2" PVC
NEW 38 KW GEN
#4 Cu
3# 2/0 Cu
W/175 AMPS
.. ... . . .
. . ..
1# 6 Cu
OCPD
• • • • _• .
• • • �'
• • •
6# 18 Cu
22 KAIC
• •• • • • •
••• •
ontra
•• ••• •• •
• • ••
Wires
NOTES: * SYSTEM WILL BE BONDING AND GROUNDING TQ.MT.ER PIP. , q"
ro1ect:...
LONDON RICKI, 9290 N. BAYSHORE
GENERATOR SUPERCENTER OF BROWARD
PIPE, TV AND PHONE. 2 GROUND ROD 5/8" X 8';ACCO4tDIN&TO Nit
: : :
DR, MIAMI SHORES FL. 33138
3800 NORTH 28TH TERRACE
250 •.• % '.' '.•
Date;• ;•
10/21/19
Approved b
HOLLYWOOD FL. 33020
** ALL WIRE TO USE WILL BE THWN OR DIRECT BURIAL CABLE WITH
Scale:
N.T.S.
PHONE: 305-900-5055 EXT. 4
3#3Cu. 1#8Cu . 6#18Cu. (ONLY FROM GENERAT _ _
rayon BY:
C.C.
M E. To
LICENSE: EC13008869
Notary Public State of Fbri • • • • • • •
Carlo Cavallo • . . • . . • • . • •
My Commission GG 3236 5 • • • • • • •
�orw�
Expires 05/30/2023
AS BUILT LOAD ANALYSIS CALCULATIONS
**Gas appliances are not used**
QTY or Amp
VA
Totals
Living square feet:
3,450
3
10,350
Small Appliance Circuits (min 2)
3
1,500
4,500
Microwave
1
1,200
1,200
Cooktop
GAS
6,700
0
Wall Oven
1
7,000
7,000
Garbage Disposal
1
600
600
Dryer
1
5,000
5,000
120v Laundry Circuit (1 req)
2
1,500
3,000
Refrigerator
2
500
1,000
Dishwasher
1
1,200
1,200
Garage door Opener
1
500
500
Water Heater
GAS 1
5,000
1 0
A
Total General
load:
1 34,350
NOTES:
C=(A-10,000 0.4)
D = B + C
F = D + E
G = F / 240 Volts
B First 10kva @ 100%: 1 10,000
C I Remaining va x 40%: 1 9,740
D Sub total general load:
19,740
E Total AC load @ 100%:
15,000
F Total Load (VA):
34,740
G Calculated Load (Amp):
145
Kilowatts Calculated:
34.74
c Notary Public State <
Carlo Cavallo
„• My Commmsion GG
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
A/C Unit
KW
A/C 1
7.5
A/C 2
7.5
Total AC
Load (VA) 15,000
Panel 1 amp size (Amp): 200
ELECTRICAL
REVIEW, v
APPROVED lj9
ATE
Project: LONDON RICKI, 9290 N. BAYSHORE
.. ••• .. ... ••• DR, MIAMI SHORES FL. 33138
•• �•� �• a 10/21/19 Approved buy;. —
Scaler
N.T.S.
Drawn Bv: C.C. W1VriareJTosa5
••• • • • • ••• • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
Sales
Person:
GENERATOR SUPERCENTER OF BROWARD
3800 NORTH 28TH TERRACE
HOLLYWOOD FL. 33020
PHONE: 305-900-5055 EXT. 4
LICENSE: EC13008869
PROPOSED LOAD ANALYSIS CALCULATIONS
**Gas appliances are not used**
QTY or Amp
VA
Totals
Living square feet:
3,450
3
10,350
Small Appliance Circuits (min 2)
3
1,500
4,500
Microwave
1
1,200
1,200
Cooktop
GAS
6,700
0
Wall Oven
1
7,000
7,000
Garbage Disposal
1
600
600
Dryer
1
5,000
5,000
120v Laundry Circuit (1 req)
2
1,500
3,000
Refrigerator
2
500
1,000
Dishwasher
1
1,200
1,200
Garage door Opener
1
500
500
Water Heater
GAS
5,000
0
A
Total General load:
34,350
B First 10kva @ 100%: 1 10,000
C=(A-10,000 0.4) C1 Remaining va x 40%: 1 9,740
D = B + C D
E
F = D + E F
G = F / 240 Volts G
Sub total general load:
19,740
Total AC load @ 100%:
15,000
Total Load (VA):
34,740
Calculated Load (Amp):
14
Kilowatts Calculated:
38kw
Generator to Install
38 KW
A/C Unit
KW
A/C 1
7.5
A/C 2
7.5
Panel 1 amp size (Amp): 200
ELECTRICAL REVIEW 41 !p
APPROVED DATE
Total AC
Load (VA) 15,000
NOTES:
Project:
LONDON RICKI, 9290 N. BAYSHORE
GENERATOR SUPERCENTER OF BROWARD
DR, MIAMI SHORES FL. 33138
3800 NORTH 28TH TERRACE
�o%r xy.s, Notary Public State of FI ida
Carlo Cavallo
• • • •
• •
• •
• •
•
• •
HOLLYWOOD FL. 33020
• •
Cafe: .. 10/21/19
Approv ci b
Scale:
N.T.S.
My Commission GG 323 0
PHONE: 305-900-5055 EXT. 4
�+i�a Expires 06/30/2023
Mi . Tosar
LICENSE: EC13008869
Drawn By: C.C.
. . .
... .
. .
. .
. . . . .
... . .
ELECTRICAL.REVIEW APPROVE ATE N E R AC@
Protector Q PROTECTOR® QS SERIES
Series Standby Generators
009- Liquid -Cooled Gaseous Engine
INCLUDES: Standby Power Rating
• Two -Line LCD Multilingual Digital
Evolution`"" Controller (English/Spanish/
French/Portuguese) with external viewing
window for easy indication of generator
status and breaker position.
• True Power'" Electrical Technology
• Isochronous Electronic Governor
Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz
Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz
Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz
OlModel RGO38_(Altaminum - Bisque) - 38 kW 60 Hz
Model RG048 (Alurrlir7um - Bisque) - 48 kW 60 Hz
W
• Sound Attenuated Enclosure
• Closed Coolant Recovery System I� _
• Smart Battery Charger
• UV/Ozone Resistant Hoses
• ±1% Voltage Regulation
• Natural Gas or LP Operation
:*see:
• 5 Year Limited Warranty •.•• .• •
ETA .. .
• UL 2200 Listed ���(J��_ �����•
• . • .
• Capability to be installed within 18" "�' °mm•NAG" •• •••• ••••••
Yaneelk s,O MdP W�
(457) mm of a building* Meets EPA Emission Regulations
*Only if located away from doors, windows, and fresh air 22 & 27 kW are CAA emissiM66mpliant ...•32 8:38 144not for sale in CA / MSS.. • •:
intakes, and unless otherwise directed by local codes. • • • • • • . •
FEATURES
O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of
GENERAC'S success in "IMPROVING POWER BY DESIGN." But it
doesn't stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose GENERAC POWER SYSTEMS with the confidence that these
systems will provide superior performance.
C SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1%.
C SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
O TEST CRITERIA: C GENERAC TRANSFER SWITCHES. Long life and reliability are
PROTOTYPE TESTED NEMA M131-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
SYSTEM TORSIONAL TESTED Y MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibi:,ty.
• 900
�. Aso1'
22 • 27 a 32 f38 148 kW
164k,14 1t101111ateafM1111121
Type
Synchronous
Rotor Insulation Class
H (22 & 27 kW) or
F (32, 38 & 48 kW)
Stator Insulation Class
H
Telephone Interference Factor (TIF)
<50
Alternator Output Leads 1-Phase
4 wire
Alternator Output Leads 3-Phase
6 wire
Bearings
Sealed Ball
Coupling
Flexible Disc
Excitation System
Direct
VOLTAGE REGULATION
Type
Electronic
Sensing
Single Phase
Regulation
zt 1%
GOVERNOR SPECIFICATIONS
Type
Electronic
Frequency Regulation
Isochronous
Steady State Regulation
± 0.25%
ELECTRICAL SYSTEM
Battery Charge Alternator
12 Volt 30 Amp
Static Battery Charger
2.5 Amp
Recommended Battery (battery not included)
Group 26 (22, 27, 32 & 38 kW)
or Group 24F (48 kW), 525CCA
System Voltage
12 Volts
GENERATOR FEATURES
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Class H insulation is NEMA rated
Class F insulation is NEMA rated
All models fully prototyped tested
ENCLOSURE FEATURES
Aluminum weather
Ensures protection against mother nature.
protective enclosure
Electrostatically applied textured epoxy paint for added
durability.
Enclosed critical grade
Quiet, critical grade muffler is mounted inside the unit
muffler
to prevent injuries.
Small, compact, attractive
Makes for an easy, eye appealing installation.
SAE
Sound attenuated enclosure ensures quiet operation.
(All ratings in accordance with BS5514, IS03046, IS08528; SAE J1349 and DIN6271)
GENERAC®
application & engineering data
ENGINE SPECIFICATIONS: 22, 27, 32 68 k
Make
Generac
Model
In -line
Cylinders
4
Displacement (Liters)
2.4
Bore (in/mm)
3.41/86.5
Stroke (in/mm)
3.94/100
Compression Ratio
9.5:1
Intake Air System
Naturally Aspirated (22 & 27 kW) or
Turbocharged/Aftercooled
(32 & 38 kW)
Lifter Type
Hydraulic
ENGINE SPECIFICATIONS: 48 kW
Make
Generac
Model
VType
Cylinders
8
Displacement (Liters)
5.4
Bore (in/mm)
• • • • • • 3.55/90.2
Stroke (in/mm) ' •.
; .. •. 4.17/105
9
•'
•
is �
ENGINE LUBRICATION SYSTEM • •: • •: : .09.
Oil Pump Type ...
.. . Gear
Oil Filter Type •
• Full Now spir:on cartridge
:
• 04/3.8 (22' 27, & 38 kW) Qr
Crankcase Capacity (qUl) •
.2
• • C15,7 (48 kA
ENGINE COOLING SYSTEM
Type
Closed
Water Pump
Belt driven
1980 - 22 & 27 kW
Fan Speed (rpm)
1500 - 32 & 38 kW
1954 - 48 kW
Fan Diameter (in/mm)
18.1/459.7 (22 & 27 kW) or
22/558.8 (32, 38 & 48 kW)
Pusher (22 & 27 kW) or
Fan Mode
Puller (32, 38 & 48 kW)
FUEL SYSTEM
Fuel Type
Natural gas, propane vapor
Carburetor
Down Draft
Secondary Fuel Regulator
Standard
Fuel Shut Off Solenoid
Standard
Operating Fuel Pressure
5-14" water column/9-26 mm HG
LP Fuel Pressure
11 -14" Water Column
NG Fuel Pressure
5 -14° Water Column
•
22.27.32•P8J)48kW
GENERAC®
operating data
GENERATOR OUTPUT VOLTAGEAW - 60 Hz
kW LPG Amp LPG kW Nat. Gas Amp Nat. Gas CB Size (Both)
120/240 V, 10, 1.0 pf
22
92
22
92
100
RG022
120/208 V, 30, 0.8 pf
22
76
22
76
80
120/240 V, 30, 0.8 pf
22
66
22
66
80
120/240 V, 10, 1.0 pf
27
113
25
104
125
RG027
120/208 V, 30, 0.8 pf
27
94
25
87
100
120/240 V, 30, 0.8 pf
27
81
25
75
90
120/240 V, 10, 1.0 pf
32
133
32
133
150
120/208 V, 30, 0.8 pf
32
111
32
111
125
RG032
120/240 V, 30, 0.8 pf
32
96
32
96
100
277/480 V, 30, 0.8 pf
32
48
32
48
60
120/240 V, 10, 1.0 pf
38
158
38
158
175
120/208 V. 30, 0.8 pf
38
132
38
132
150
RG038
120/240 V, 30, 0.8 pf
38
114
38
114
125
277/480 V, 30, 0.8 pf
38
57
38
57
60
120/240 V, 10, 1.0 pf
48
200
48
200
200
120/208 V, 30, 0.8 pf
48
167
48
167
175
RG048
120/240 V, 30, 0.8 pf
48
144
48
144
;...N
277/480 V, 30, 0.8 pf
48
72
48
1 •72 • •
80
•::-
SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION •
Voltage Dip @ < .4 pf Natural �Z .. •Pfopape : • • • •
15% 30% (1113/hr) tr**o • •(gal/hr) ** (I/Mr} • (ft3/hr} • • • •
•
120/240 V, 10
55
135
RG022
120/208 V, 30
40
92
120/240 V, 30
35
80
120/240 V, 10
62
170
RG027
120/208 V, 30
70
120
120/240 V, 30
61
103
120/240 V, 10
75
180
120/208 V, 30
87
210
RG032
120/240 V, 30
75
182
277/480 V, 30
36
87
120/240 V, 10
75
180
120/208 V, 30
87
210
RG038
120/240 V, 30
75
182
277/480 V, 30
36
87
120/240 V, 10
85
195
120/208 V, 30
90
218
RG048
120/240 V, 30
78
189
277/480 V, 30
36
87
Note: Fuel pipe must be sized for full load.
For Btu content, multiply W/hr x 2520 (LP) or ft3/hr x 1000 (NG)
For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG)
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and
SCAQMD permitting purposes.
Exercise cycle
42
• % •
: 0.44
J.T
16 '
25% of rated load
100
1.8 •
1.1
1.2 •
40
RG022
50% of rated load
190
•5.4 •
• 2.1
7.8
75
75% of rated load
255
7.2
2.8
't 5"
101 •
100% of rated load
316
* •9. •
: 3.4
19.
125 •
Exercise cycle
42
1.2
0.44
•1.1 •
16
25% of rated load
108
3.1
1.2
4.5
43
RG027
50% of rated load
197
5.6
2.1
8.1
78
75% of rated load
287
8.2
3.1
11.8
114
100% of rated load
359
10.2
3.9
14.8
143
Exercise cycle
79
2.2
0.8
3.2
30
25% of rated load
144
4.1
1.7
6.3
60
RG032
50% of rated load
226
6.4
2.7
10.3
97
75% of rated load
298
6.4
3.7
13.9
132
100% of rated load
375
10.6
4.6
17.5
166
Exercise cycle
83
2.3
1 0.9
3.2
1 31
25% of rated load
162
4.6
1.7
6.6
62
RG038
50% of rated load
255
7.2
2.9
10.8
103
75% of rated load
345
9.8
4
15
142
100% of rated load
437
12.4
5.2
19
185
Exercise cycle
95
2.7
1
3.9
38
25% of rated load
204
5.8
2.16
8.5
82
RG048
50% of rated load
392
11.1
4.14
15.7
151
75% of rated load
547
15.5
5.8
22.8
220
100% of rated load
756
21.5
7.96
31.3
302
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There
is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice.
22 • 27 a 32 •' 38 ) 48 kW
ENGINE COOLING
GENERAC®
operating data
22 kW 27 kW 32 38 kW 48 kW
Air flow (inlet air including alternator and combustion air in cfm/cmm)
2400/68
2400/68
2200/62.3
4350/123.2
System coolant capacity (gal/liters)
2.5/9.5
2.5/9.5
2.5/9.5
3/11.4
Heat rejection to coolant (BTU per hr/MJ per hr)
99,000/104.5
105,000/110.8
145,000/153
186,000/196.2
Maximum operation air temperature on radiator (°CPF)
60/150
Maximum ambient temperature (°C/°F)
50/140
COMBUSTION REQUIREMENTS
Flow at rated power (cfm/cmm) 68/1.9 68/1.9 106/3 163/4.6
SOUND EMISSIONS
Sound output in dB(A) at 23 It (7 m) with generator in exercise mode`
61
61
58
63
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load'
70
70
64
68
'Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters.
EXHAUST
Exhaust flow at rated output (cfm/cmm)
165/4.7
180/5.1
300/8.5
*14/11.7
Exhaust temperature at muffler outlet (°CPF)
1 482/900
538/1000
; 5JI/V75
552/1025
ENGINE PARAMETERS
•••••• •••' ••"••
Rated Synchronous rpm
.....•
18000000 • • • . •
•••• • •• •••••
• •• •••••
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
•
.. .. .'... ......
Temperature Deration...........................................................................................................3%
for every 10 °C above 25 °C Qr'1'!8�5'%;or every 10 'f above 77 °F •
Altitude Deration (22, 27 & 48 kW).....................................................................................1
% for every 100 m above 183 mror 3% fot every 19QQ fI jbpe 6004t• • • • •
Altitude Deration (32 & 38 kW).......................................................................................
1 °% for every 100 m above 915 m (; 39%jer jevery 1000 ft above 30004
• •
CONTROLLER FEATURES
Two -Line Plain Text LCD Display....................................................................................................................................Simple
user interface for ease of operation.
Mode Switch: Auto..............................................................................................................................................Automatic
Start on Utility failure. 7 day exerciser
Off...........................................................................................................................Stops
unit. Power is removed. Control and charger still operate.
Manual.........................................................................................
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Programmable start delay between 10-30 seconds.................................................................................................................................................10
sec standard
Engine Start Sequence.....................................................................................................................
Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)
EngineWarm-up.....................................................................................................................................................................................................................5
sec
EngineCool-Down..................................................................................................................................................................................................................1
min
Starter Lock-out...............................................................................................................................Starter
cannot re-engage until 5 sec after engine has stopped.
SmartBattery Charger........................................................................................................................................................................................................
Standard
Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................
Standard
AutomaticLow Oil Pressure Shutdown...............................................................................................................................................................................
Standard
OverspeedShutdown..............................................................................................................................................................................................
Standard, 72 Hz
HighTemperature Shutdown.............................................................................................................................................................................................
Standard
OvercrankProtection..........................................................................................................................................................................................................Standard
SafetyFused......................................................................................................................................................................................................................
Standard
Failureto Transfer Protection..............................................................................................................................................................................................Standard
LowBattery Protection ....................... .... -...................... ...........................................................................
............................................................ .............. Standard
50 Event Run Log...............................................................................................................................................................................................................
Standard
FutureSet Capable Exerciser..............................................................................................................................................................................................
Standard
IncorrectWiring Protection.................................................................................................................................................................................................
Standard
InternalFault Protection.....................................................................................................................................................................................................
Standard
CommonExternal Fault Capability......................................................................................................................................................................................Standard
GovernorFailure Protection................................................................................................................................................................................................Standard
22.27.32
Model #
IG006463-4
48 kW
Product
Mobile Link TM
GENEiiiii'lloWRAC®
available accessories
Description _
Generac's Mobile Link allows you to check the status of your generator from {
anywhere that you have access to an Internet connection from a PC or with P
any smart device. You will even be notified when a change in the generator's
status occurs via e-mail or text message. Note: Harness Adapter Kit required. I
Available in the U.S. only.
G006478-0 Harness Adapter Kit = The Harness Adapter Kit is required to make liquid -cooled units compatible
with Mobile Link'".
G005630-1 - 22, 27, 32 & 38 kW 3 If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit
G005632-1- 48 kW Cold Weather Kit to maintain optimal battery temperature. Kit consists of battery warmer with
thermostat built into the wrap.
.......... x..... ..............:
G005616-0 - 22, 27, 32 & 38 kW Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for
G007088-0 - 48 kW i Weather Kit extended periods of time. For liquid cooled units only.
G005651-0 1 Base Plug Kit
Add base plugs to the base of the generator to keep out debris,
•
If the generator enclosure is scratched or damaveo, it is impor4anlio • • •
• • •,
G005703-0 - Bisque Paint Kit
touch-up the paint to protect from future corroslo��UP' paint kit in%lutles the,
necessary paint to properly maintain or touch-up gWerator Wlosgre. ; ! • • •;
G005656-0 - 22 & 27 kW
---------------
The Liquid -Cooled Scheduled Maintenance Kits • • • •I the ha dw • • • • •
c are
Scheduled
G005984-0 - 32 & 38 kW
.kcal ....
•
necessary to perform complete maintenance oq �tpOc IiquiA;D9Wd *too:*
Maintenance Kit
G006205-0 - 48 kW
; generators. .. • •.. .
_. _. _ _ _.M_.. .........
_...__... _.._.... ..._:.. •_. __._. ___._
G006664-0 Local Wireless
Completely wireless and battery powered, GenE:ac'F.Weless remote monitoC ...:
Monitor
provides you with instant status information with86t ever leavidg ihMuse. •
.-_.......
----------------
G006665-0 Wireless Remote
Recommended for use with the Wireless Remote on units up to 60 kW,
Extension Harness
required for use on units 70 kW or greater.
-�
Smart Management Modules are used in conjunction with the Automatic
G006873-0 = Smart Management Transfer Switch to increase its power management capabilities. It provides
Module (50 Amps) additional power management flexibility not found in any other power s
management system
-------- ...___.._
E-stop allows for immediate fuel shutoff and generator shutdown in the event
G006510-0 E-Stop
I of an emergency. g
�ve. _... . n.,.... ......... .. __------ --
�..------------- _ .— ......._.� _--.a--......._
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the
Wi-Fi LP Fuel Level
connected LP fuel tank. Monitoring the LP tank's fuel level is an important
G007005-0 Monitor
step in making sure your generator is ready to run during an unexpected
power failure. Status alerts are available through a free application to notify
when vour LP tank is in need of a refill.
2.5" O.D.
RADIATOR/EXHAUST
DISCHARGE AIR
AIR INTAKE
(BOTH SIDES)
(BOTH SIDES
4
766 [30.2]—�
CENTER OF GRAVITY
167
SEE NOTE 5
[6.6]
Ti—f--
535
[21.1]
OUTLET
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
3
RADIATOR/EXHAUST
DISCHARGE AIR
TOP VIEW BATTERY 12V, GRP 26
NEGATIVE GROUND
PIN 077483
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
SERVICE ITEM
2.41L
OIL FILL CAP
EITHER SIDE
OIL DIP STICK
RIGHT SIDE
OIL FILTER
RIGHT SIDE
OIL DRAM HOSE
RADIATOR ORAN HOSE
COOLANT RECOVERY BOTTLE
RIGHT SIDE
LEFT SIDE
LEFT SIDE
RADIATOR FILL CAP ACCESS
ROOFTOP
PAR CLEANER ELEMENT
RIGHT SIDE
SPARK PLUGS
LEFT SIDE
MUFFLER
SEE NOTE 11
ORIVE BE
E'HER SIDE
FAN BELT
SEE NOTE 11
BATTERY
LEFT SIDE
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
CIRCUIT BREAKE
SEE NOTE 3
NOTES
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47'1 WIDE X 2255 (88.8') LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB -UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION, NEUTRAL
CONNECTION, AND BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10, GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST MUFFLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE FRONT PANEL TO ACCESS.
01t
ai, !
REAR ENCLOSURE
COVER PANEL
;•
1171[461]
SEE NOTE 4
x"
OVERALL
HEIGHT
-
CUSTOMER ACCESS
G •
•
1.
ASSEMBLY, CONTROL
j`-
L
PANEL ACCESS,
BATTERY CHARGER
VICE ACTION LATCH,
ONE PER DOOR,
-- 759 [29.9] ONE LIFT OFF
DOOR TYP DOOR PER SIDE
OF GENERATOR
a,.
LOCATED WITHIN
-^--
SEE NOTE 4
[2.0]
7
868 [35.0]
47
1857 [73.1 ] TYP
58
FUEL LINE CONNECTIO
1000 [39.4]
OVERALL WIDTH
1950 [78.6]—I
[2.3]
3/a^ NPT FEMALE couhLwG
REAR VIEW
TYP1
OVERALL LENGTH
TYP
LEFT SIDE
VIEW
LIFTING PROVISIONS
• • 000
• • • • •
• •
RIGHT SIDE VIEW
(4 PLACES)
• •
• • • • • •
•
SEE NOTES 5,7 AND
• •
• • • • • •
•
CENTER OF GRAVITY DIMENSIONS
WEIGHT DATA
•
• • • • • • •
•
ENGINE/KW
ENCLOSURE
WEIGHT
WEIGHT
SHIPPINGSKID SHIP%NS1'(�IOHT
• •
• • • • •
• •
MATERIAL
KG
KG [LBSI
KG [LIS KG [LSSI
24L 32KW
AL
556 [I225j
441SS] soo 113231
DIMENSIONS: MM [INCH]
24L 36KW
_ AL_
560 [I2%j
44I96j. 605113331
•.
•. •
• .
.....
.. ..
. .
. • • •
. • . • .
• • •
• ••
•• • • • ••
••
000 0
0 0 000 0
•
50 TYP
[2.0]
LEELSIDE VIEW
• • • • • • • • • • • BEAR VIEW
•• ••• •• • • • ••
•• •• ••• •• •••••
.. •. ...
• • • • • • • • • • •
• • • . • • • • • • • •
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
VECTIONS.
4 OPENING.
P ACCESS COVER
-H GENERATOR)
RING GENERATOR
0
i
GENERAC6
POWER SYSTEMS, INC.
No se permiten ventanas ni aberturas an Is pared a una distanaa
de 5 pies de cualquier pane del generador.
r r� Pared Existente Distancia Minima
60 Pulgadas Pulgadas
de 18 Pulgadas
Espacio libre desde
36 Pulgadas Parts Superior del 36 Pulgadas ventanas, puertas,
Generador cualquier abertura an la
pared, arbustos o
vegetaci6n de m2s de 12"
de allure
Esas directrlces est3n basadas en
I El espacio libre desde los extremos y Is pane delantera
pruebas de la Fire generador recinto y el
del generador debe ser de 36 pulgadas. Esto incluiria
fabricante requisite de sire Flow pars
36 Pulgadas
arbustos, rboles uier tiEl
3 y alal q de veger n.
un funcionamiento correcto. Local
de minimo
superior debe ser de
espacio libre an la or m
codigos pueden ser diferente y mas
de de c er
cualquier estrugeneradoum,r
pulgadas desdesde
restrictive que to qua se describe aqui.
proyecciones desde la pared. El generador no debe
ye ]a o d b
oclocarse debajo de una cubierta u oira estructura que
est6 cerrada y que limitar!a o conlendria el flujo del a:re.
Este dibujo anula las instrucciones de instaiaci6n de todos los manuales de instalaci6n y del propietario • •
de equipos de Generac enfriados con aire cuya fecha de publicaci6n sea anterior al 26 de mayo de 2007.
3 LVCI -��IAOHdcff
I��' �y 7 n � �1 , � 11 �00�-@7� lry'ol snolnajd
palep slenuew s,ja o pue uogegelsul pal000ale oeuauaaau&prcysul Uv1WldycuFkapb�ad 6ulmeup slyl
wnw!u!yl
segout g;
Mol; ae u!eluoo to
1!w!I pinom Pus u! pesop sl legl amen:is
:aulo:u Naep e:epun peoe;d aq
lou pinogs :olei 015 agl Hem e41 woy
suoiloalwd :o 6ueWow'amlo"s Aue
woy sagou, gq;o wnuliulw !n a aq nogs
dol eLn Is aoue:ea!D 'uo1;ele6an10 pup!
Aue pue sesq'sgmgs epgw, pin—
sui sagou! go aq pinogs jolwauaf
agl;o luny pus spua aq1 wow; aoue:eal;
spu3 waj wnw!u!y+1
popuawwooaa „09
sagou! go
aope:aueo
wnwlu!A „g,
-ajag paquosap sl legm uegl
and;oujsaJ aJOw pue lua3ajjlp aq Aew
sapooleool uollejadouadoudiojmog
ale joj lueweipbai s jainloejnuew aql
pue amsoloua jojejaua6 agl jo 6upsal
aril uodn paseq aje soullapinb asegj
Ig6!8q ul.Z, iano
uogela6en jo sgn:gs'Ile.
aql u! sbu!uado Aue'sroop sagou! 9c :oa,.ua0;o dol sa(aul 9c
'smopu!m woy awtuearo
• • • aouels!U wnw!u!y4
• • • • • sagou! Og sagoul gl Ilem rugslx3 sagou! 09
• •� . .,
• • • • • uolejau96 ay1;o wiod Aue woy lea; S u!gl!m
par,!uuad Ilem aql ui s6wuedo:o smopulm ON
;. •• ; ; ONI SINElIS)�S HDAAOd
.. . . . • . • ..
••• • • • • ••• • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
UOR MODEL RG048
2'-11"
i
3
,2)
�.0
GENERATOR RG048 ISOMETRIC
SCALE: N.T.S. (4) ELCO LILTRACON
EA. SIDE W/2- MIN. EMS.
Nota bli to of Florida
4e. � Carl av
i on GG 323605
x it S 0 12023
, ' - -
Dote: -
D�e: -
Date -
�te: -
DOte: -
DOIe: -
Dote. -
Date0'
: -
CheckeO Approved
STRUCTURAL NOTES
GENERAL NOTES:
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT ARCHITECTURAL
DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS.
APPLICABLE BUILDING CODE STANDARDS: FBC-2017 6th EDITION, ASCE /-10 & ACI 36OR-10
ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE
CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A
DIFFERENT DETAIL IS SHOWN. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO
NOT SCALE THE DRAWINGS FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH THE AFFECTED PART OF
THE WORK.
IT IS THE CONTRACTOR'S RESPONS0111TY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO
INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION.
CONCRETE SLAG ON GRADE.
CONCRETE PAD WAS DESIGNED FOR AN ALLOWABLE SOIL. BEARING PRESSURE OF 1,500 psl ON
COMPACTED FILL. CONCRETE SHALL BE AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE
A STRENGTH AT 28 DAYS Of 3.000 psi
DESIGN LOADS:
WIND- DESIGN WIND SPEED = 175 mph 3-SECOND GJST
e0
I
ro
(ASCE 7-10 (FBC 2017 61h ED.) EXPOSURE C, CATEGORY If)
WIND PRFSSURF--43.82 psl
F-2.046.97 Ibs
Fh=1,226.92 Ibs
-- GENERATOR MODEL RG048 Mo=5,721 16 tUbs (OVERTURNING MOMENT)
3'-9"x 7'-6"x 9" CONC. SLAB
ON GRADE, f'c=3,000 psi & (2)
LAYERS OF 6"x 6"- W2.OxW2.0
* 4'-6"
R SPECIFICATIONS:
HEIGHT=46.' .
LENGTH=76.8"
GENERATOR RG048
ELEVATION
WIDTH=35"
WEIGHT=1.5551bs
SCALJ: ..S
• • • • •
• • •
CONC. SLAB
& ANCHORING
FOR
GENERATOR
• •
••
• •
•• •
• •
• •
-•
•
'00
••• •.•
DA'q�
C:YUNTY
sees
• • • • • • • • • •
• •• •• • • • •• ••
000 0 0 0 000 • 0
CONKRETA BUILDERS LLC.
3800 N 28T" TERRACE
HOLLYWOOD FL. 33020
LIC.: CGC1525680
GILBERT D. MORALES
S E PLAN D,9 NO. - No. --- SO-1
T
LOT- 11
BLOCK - 2
F. I. P 3/4"
NO CAP,
87.50*
0. 30'CL.
4! C.L.F.* '* � *
5,27 5.1
aCR
vi
4.95 25.80'
4'C.L.F.
A/C
C3
26,30-
A3,
LOT - 13
BLOCK - 2 r zz
8.80,
POOL
PUMP
ONE STORY
RES. # 9290
LOT - 12
BLOCK-2
F,F,E.=T8T
L,Fl.=7.31'
GARAGE ELEV.=5.72'
24.70' 00
wk. G.m
4.91
7.30'
4.82
t
fV
F,I.P 3/4'
NO CAP
5.12
25.00'
4.69
CONC. PRIY E,
IK •
4.95
7
4.15
92
-v or —
see?
4.92
*
•es
250 0 0:
.00'
•
475 NO ID. x/l- t
0 co
3,54
0 Em
87.50, C�
0! 'go
-v-t,9 10 .711*214^ "1 m:�,(
NEW 38 KW GENERATOR N ' 0
4P-
OVER CONCRETE SLAB AT
10C' rA
7.31'NGVD. MORE THAN L27-
10 FT FROM ANY VENTS, timnn2,%00` %.'sxel
DOORS, WINDOWS,
OPENINGS FROM EXHAUST BA RE 4.09 DRIVE 2
SIDE. SCREENED WITH
< SHRUBS OR FENCE FROM 118'ASPHALT
0 STREET VIEW.
F-'q
Project: LONDON RICKI, 9290 N BAYSHORE DR. MIAMI ADVANTAGE GAS SERVICES
SHORES FL. 33138 16891 SW 139th PLACE
Date: 10/21/19 App MIAMI FL. 33177
Scale: N.T.S 1� PHONE: 305-979-8281
Drawn By: C.C. r7Damel �Santan7 LICENSE LPGX: L142062
EXISTING APPLIANCES
Exist. Tankless W/H
Existing Cooktop
New 38 kw Generator
O
! CITY
�i3AS
;D
'GAPPE
GAS TYP .
TOTAL DEMAN BT
LONGEST RUN:
INLET PRESSURE:
PRESSURE DROP:
SPECIFIC GRAVITY:
PIPE MATERIAL:
F.B.0 TABLE:
NATURAL GAS LOAD ANALYSIS AND ISOMETRIC
QTY
BTU
Total BTU
2
190,000
380,000
1
35,000
35,000
1
1 437,000
1 437,000
T0TALBTUJ
852,000
6
G. M.
IGN CRITERIA
NATURAL
852,000
50
Less than 2.0 psi
6.0" w.c.
0.6
SCHED. 40 METALIC,
POLYETHYLENE
402.4 (4), 404' *M$
Notary Public Stale of
Carlo Cavallo
My Commission GG
w Expires 06/30/2023
PIPE SIZED BY BRANCH LENGTH METHOD FBC 402.4.2
G%�`�"�
3 t e►
70
EXISTING
J
900W/H
1.00BTU
tz
c¢7
EXISTING
n
`
W/H
"
190000 BTU
31A
1Y"
�,j
30 �
•• • • . •
. .. • ... •.. .
• . • • . . •
Project: LONDON RICKI, 9290 N. BAYSHORE
• ' •:• .•*DA:IAIAKAr$HMtS FL. 33138
Date;. ' .10/2j/i9 : BPProved�y:
Scale:
rI.T.S.
yawn By:
C.C.
.. . .
.
. Or
.
.
• • • •
• • •
•
• •
• •• ••
• • •
••
••
SEDIMENT
TRAP
P
EXISTING
COOKTOP
35000
BTU
NEW 38 KW
GENERATOR
43700O BTU
0PW
ADVANTAGE GAS SERVICES
16891 SW 139 PL.
MIAMI FL. 33177
PHONE: 305-979-8281
LPGX LIC: 42062