Loading...
CC-19-2472Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Issue Date:11/25/2019 Parcel Number 1700 NE 105TH ST 319, Miami Shores, FL 33138 1122300500570 Contacts Permit NO.: CC-10-19-2472 Permit type: Building (Commercial) Work Classification: Alteration Permit Status: Approved Expiration: 05/26/2020 ANN JUSTIZ Owner 1700 NE 105 ST 319 Business: 3057857727 justizonita@gmail.com DVG BUILDERS INC Contractor DANIEL GARCIA 2930 SW 115 AVE, MIAMI, FL 33165 Business: 3055067308 jbringas23@yahoo.com Description: REMOVE CARPET AND INSTALL VYNYL FLOORING Valuation: $ 10,000.0Inspection Requests: 0 Inspect 4949 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $6.00 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $2.00 Permit Fee $250.00 Scanning Fee $9.00 Technology Fee $7.50 Total: $332.00 Building Department Copy Payments Date Paid Amt Paid Total Fees $332.00 Credit Card 11/25/2019 $332.00 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named con actor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Date November 25, 2019 Page 2 of 2 -ter-4 JL BRED BUILDING PERMIT APPLICATION Yj'BUILDING ❑ ELECTRIC Miami Shores Village ccl 17 2 19 Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 � �O r 7 (L' FBC 201 Master Permit No. CC- ( 1�-- f) - 24--1 2 Sub Permit No. ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: I I U0 IQ if I d-5 S-t- Folio/Parcel#: / �' s?ef- 3 O- ©.!;'O -0 Z--- Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER N' ame (Fee Simple Titleholder): L�' !� ^ J�-t' Phone#: CIE- - 1 a -yam City: M�� ^'� � S�' 1(j �''� State: � `�1 � . Zip: Tenant/-Leessse'ecN.aam.�e: /'�� ` Phone#: Email: \" �QQC\ JAP, "" J � h�� 1 • C' `�FX CONTRACTOR: Company Name: JD '�) �� +� ��,>°�� 1 0l C Phone#:3US' Address: City: M + Q ^jj��� State: Zip: 33 1 LP5 Qualifier Name: VJ Q'� �'l Gee' a a1 Phone#: 3yS 5 ouO State Certification or Registration #: Ce:)C 1 5 ! C1 D'3 -)- Certificate of Competency #: DESIGNER: Architect/Engineer: Address: City: hone#: Zip: Value of Work for this Permit: $ Square/Linear Foota a of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑Demolition Description of Work: J? CIn-,.I C'--Q CC12 p-f f-I sov did pe-O F N / u n III oa- R 4 Specify color o '010 fh ft till: ,y,..y l,rS. F k,•�.. aw Submittal Fee $ Vermif Fee $' ` C/J CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ (Revised02/24/2014) Bond $ TOTAL FEE NOW DUE $ �� �� Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit i ued. In the absenc such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OW or AGENT The foregoing instrument was acknowledged before me this -in day of O«U b-C ( 20 , by Arm-) kJ S7 i Z who is�p rsonally <n to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: CONTRACTOR The f regoin strument was acknowledged beforemethis day of d C 7-0)D P2 20 1 / by �� C �►�� who is personal) wn to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: -e Print: ��a NathaNeCepero Seal: • My C MMnSpn GG 2520e7 Seal: Expros12119120Z2 APPROVED BY Plans Examiner Structural Review �r Notary public State d Florida f" &N Nathalie Cepero My C2t►3o22 iwn 252067 �`►` Expo t2r,9a2 as Zoning Clerk (Revised02/24/2014) Property Search Application - Miami -Dade County Page 1 of 1 OFFICE OF THE PROPERTY APPRAISER «� Summary Report Property Information Folio: 11-3206-013-2010 Property Address: 122 NE 101 ST Miami Shores, FL 33138-2321 Owner ANDREW J STEFANICK IV CRISTA STEFANICK .................. Mailing Address 122 NE 101 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY: 1 UNIT _ .. Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,400 Sq.Ft Lot Size 11,500 Sq. Ft Year Built 1952 Assessment Information Year 2019 2018 2017 Land Value $345,138 $287,615 $287,615 Building Value $167,040 $167,040 $167,040 XF Value $0 $0 $0 Market Value $512,178 $454,655 $454,655 Assessed Value $306,486 $300,772 $294,586 Benefits Information Benefit Type 2019 2018 2017 Save Our Homes Assessment $205,692 $153,883 $160,069 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Second Exemption $25,000 $25,000 $25,000 Homestead Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 1534165342 SHORES SEC 1 AMD PB 10-70 'S11&12BLK15 "SIZE 100.000 X 115 19886-2613 08 2001 1 Generated On : 10/17/2019 Taxable Value Information 2019 2018 2017 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $256,486 $250,772 $244,586 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $281,486 $275,772 $269,586 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $256,486 $250,772 $244,586 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $256,486 $250,772 $244,586 Sales Information Previous OR Book - Price Qualification Description Sale Page Financial inst or "in Lieu of 12/10/2010 $215,000 27521-1737 Forclosure" stated Financial inst or "in Lieu of 06/22/2010 $257,100 27345-4841 Forclosure" stated 08/01/2001 $290,000 19886-2613 Sales which are qualified 12/01/1988 $135,000 13920-3184 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp https://www8.miamidade.gov/Apps/PA/propertysearch/ 10/ 17/2019 WORK REQUEST APPLICATION (� -- C I 1 Owner's Name 1"r 4], (1 n ` �� J11 2 Unit __ I hereby request approval from the Board of Directors for the following modification or alteration to my unit that will be performed by a licensed contractor. Electrical work Plumbing work Carpet installation __.---- *Windows Tile installation Description of the work Before you decide to upgrade your'apartment (other than paint or carpet) you must obtain'I,e.:rissian from the Board of Directors and/or Miami Shores Village. Other work A copy of the plans, specifications and permits, and a description of the licensed work to be performed must be submitted for consideration and approval by the Miami Shores Village Building Department (305-795-2204). It is the owner's responsibility to ensure that the contractor removes all excess construction material or building debris. It cannot be placed in the dumpsters. **Window frames must be gray in color to Iook like aluminum. Windows must be Two (2) panels over Two (2) panels. Glass must be clear color. 1, as the unit owner acknowledge responsibility for any damage to the building or personal injuries that may occur during the project. The Shores Condominium Inc. its officers and employees are in no way responsible for damage or theft to my apartment or my belongings. (A $200.00 deposit is required and will be refunded if no damage to the property is reported.) I fully u derstand and agree to the statements made above. r Date Unit owne signature Approved by:' Date: �, SHOIZES CON®JNiiNiUM APARTMENTS 1700 N.E. 105th STREET • MIAMI SHORES, FLORIOA �3 I� r a • • • • • .,.. •..00 Lf •• SPEC= On jl� Jt;�j� 1�� j;�i r Prm" Beg&" Prodacts Tkat Protect Distributed by SoundAway 1-866-768-6381 Sales@SoundAway.com Visit us at www.SoundAway.com 1. Product Name WhisperMat-CS Primers & Accessories • No. 6000 Water -Based Rimer 2. Manufacturer Protector Wrap Co. 1955 South Cherokee St. Denver, CO 80223 (800) 759-9727 (303) 777-3001 Fax: (303) 777-9273 E-mail: info@protectowrop.com www.protectowrap.com 3. Product Description BASIC USE WhisperMat-CS is a peel -and -stick sheet membrane that reduces impact and airborne sound transmissions and isolates finished floor- ing from subfloor cracks. ft is designed for use with ceramic, porcelain and natural stone the where sound absorption is required, specified or desired. Constructed of a cross -linked polyolefin foam sheet combined with an aggressive rubberized adhesive and a polyester mesh fabric, WhisperMat-CS also has the flexibility and strength to withstand structural move- ment and concrete shrinkage cracks up to 1/4" (6.4 mm) without transferring stress load to finished tile. In addition, excellent moisture resistant properties make this a most compre- hensive underlayment for the floors. WhisperMat-CS can be applied to any structurally sound and dean surface, includ- ing concrete, plywood, gypsum underlay- ments, precast floor panels, OSB, ceramic tile, terrazzo, natural stone, leveling and patching compounds, cement baclkerboard and exist- ing VAT, VCT and vinyl floors. WhisperMat is also approved for application over radiant heated floors. Wh isperMat's sound absorption and anti - fracture properties make it an excellent system to enhance ceramic, porcelain and stone flooring installation performance in: • Condominiums • Office buildings • Apartments • Hotels ACOUSTIC TREATMENT 09 80 00 • Schools Single-family homes BENEFITS • Sound reduction: IIC: 71: STC 72 Delta IIC; 16 • Moisture resistant • Anti -fracture resistant to 1/4" (6 mm) • Provides thermal insulation • Light commercial load rating • Approved over radiant heated floors • Uniquely thin system - 110 mil (2.8 mm) • Economical PACKAGING • WhisperMat-CS is available in 36" x 40 (914 mm x 122 m) rolls • No. 6000 Primer is available in 1 gal (3.8 L) containers COMPOSITION & MATERIALS WhisperMat-CS is constructed of a top layer of reinforced polyester mesh fabric embed- ded into rubberized adhesive; a middle layer of dense, cross -linked polyolefin foam sheet- ing for additional sound reduction properties; and a bottom layer of aggressive rubberized adhesive with an attached release liner for peel -and -stick application. The underside of the membrane is tacky, pro- viding superior adhesion to concrete, steel and wood substrates. The polyester mesh fabric top makes an excellent bonding surface for latex - modified thinset and medium bed mortars. WhisperMat-CS contains no VOCs and is environmentally safe, which allows it to be used in confined areas. The aggressive rub- berized adhesive retains its flexibility through- out the floor's fife span and will not dry out or decay over time. ACCESSORY MATERIALS No. 6000 Primer is a water based primer that contains no VOCs. It comes in 1 gal (3.8 L) containers. LIMITATIONS • WhisperMat-CS is not intended for use as a waterproofing membrane • WhisperMat-CS is not recommended for use on concrete floors where hydrostatic pres- sure exists or where moisture vapor transmis- sion exceeds 4 lb (1.8 kg), as tested by the calcium chloride test method • WhisperMat-CS is not recommended for use where horizontal floor movement is greater than 1/4" (6 mm) • Existing cracks larger than 3/16" (4.8 mm) should be prepared with proper backing material prior to installation of membrane • WhisperMat-CS is not recommended to cover Prrotecto Wrap Co. ri r rrr .rrrr .. . .. .. ...... WhisperMat-a *reduces sound transmission r e r: through flow. ' • •' rrr r joints or cracks larger than 3/8" (9.5 mm) • For installations over plywood substrates and for expansion joints, refer to TCA Method F147 • For expansion joints, reference TCA Method EJ171 • Do not apply over marine -grade plywood or other substrates containing solvent based waterproofing preservatives that could chemically react with the membrane • Do not use solvent based sealants or sealers where contact with membrane may occur • When installing natural stone over WhisperMat-CS (or any other impervious membrane), it is important to maintain a thin - set thickness of 3/8" (9.5 mm) or less after the tile is embedded, even if the mortar manu- facturer allows for thicker installations. Thicker mortar beds can potentially provide suffident moisture to cause some natural stones to warp or crown • Installation procedures and jobsite conditions must be in accordance with flooring manufacturer's recommendations and TCNA installation standards 4. Technical Data APPLICABLE STANDARDS ASTM International • ASTM C482 Standard Test Method for Bond Strength of Ceramic Tile to Portland Cement • ASTM C627 Standard Test Method for Evaluating Ceramic Floor Tile Installation Systems Using the Robinson -Type Floor Tester ,%R,DATA• and MANU-SPEC are registered trademarks of Reed 9sevier Inc. The ten port SPEGDATA formal conforms to the eattorlal style Reed V of fhe corstrucfiwi Spedfvatias hstitute and s used with fhec perm6son. The mmufachuer's resporble for tec niod oco racy. *"7 Reed Corshuction Data•. AN MWs Reserved. Constriction Data SPECC �a Distributed by SoundAway 1-866-768-6381 Sales@SoundAway.com Visit us at www.SoundAway.com • ASTM D412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers - Tension • ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements • ASTM E492 Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor -Ceiling Assemblies Using the Tapping Machine • ASTM E2179 Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors Tile Council of North America JCNA) - Handbook for Ceramic Tile Installation • TCA Method F147 • TCA Method EJ 171 APPROVALS Consult manufacturer for current information on approvals by code bodies and other industry entities. ENVIRONMENTAL CONSIDERATIONS WhisperMat-CS contains no VOCs and is environmentally safe. PHYSICAL PROPERTIES • Thickness - 110 mil (2.8 mm) • Color - Gray top, black adhesive bottom • Elongation (ASTM D412) - 500% minimum (rubberized adhesive only) • Application temperature - 45 - 120 degrees F 0 - 49 degrees C) • In-service temperature -20 - 180 degrees F (-29 - 82 degrees C) • Robinson Floor Test (ASTM C627) - Rated for light commercial applications SOUND PERFORMANCE Protecto Wrap's WhdsperMat-CS has been tested by a certified independent acoustical laboratory in accordance with ASTM E492 and ASTM E90. Test construction included 6" x 6" (152 x 152 mm) quarry tiles with latex -modified thinset mortar over an 8" (203 mm) concrete slab with a sound rated gypsum board drop ceiling. Test results were Impact Isolation Class (IIC) 71 and Sound Transmission Class (STC) 72. Test results with other subfloor configurations are available by contacting Protecto Wrap Co. ACOUSTIC TREATMENT 09 80 00 Protecto Wrap Co. ...... . ... . WhisperMat-CS Composite • °' • Layers in order, top to bottom: . • + .. • Reinforced Polyester Mesh Fabric + .. .• ' Aggressive Rubberized Adhesive • Dense, Cross -Linked Polyolefin Foam • • • Aggressive Rubberized Adhesive • • + • • + Release Paper.-- WhisperMat-CS is made with 4 constraining layers. 5. Installation STORAGE & HANDLING Store all material inside in a dry space at terry peratures between 50 and 90 degrees F (10 and 32 degrees Q. Do not store in direct sunlight. Do not remove material from box until ready to use. For cold weather applications, store in a heated airspace at a temperature of 50 degrees F (10 degrees C) or higher for at least 2 days prior to application. Remove only the material that can be applied within 2 hours. PREPARATORY WORK Handle and store product according to man- ufacturer's recommendations. Deliver materials in manufacturer's original, unopened, undamaged containers with identi- fication labels intact. Store materials protected from exposure to harmful environmental con- ditions and at temperature and humidity con- ditions recommended by the manufacturer. Verify that site conditions are acceptable for installation. Do not proceed with installation until unacceptable conditions are corrected. Surface Preparation Follow flooring manufacturer's recommended installation instructions. Installation and sub - floor requirements must also conform to TCNA standards. Flooring and membrane must acclimate to jobsite conditions before installation. Concrete subfloors must be dry, clean and free of dirt, grease, wax, paint, oil or anything that would adversely affect adhesion of the WhisperMat. Check subfloor for excessive moisture. If subfloor moisture/vapor is beyond 4 lb (1.8 kg) emissions WhisperMat-CS membrane cannot be used (see Limitations). Leveling cements must be completely dry before membrane application. APPLICATION Priming Always apply the Protecto Wrap No. 6000 Primer to the subfloor and allow to dry (approx- imately 20 - 30 minutes) before installing the WhisperMat-CS to ensure a good bond. Layout Unroll WhispperMat-CS with the release liner side down. Cut the length approximately 12" (305 mm) longer than the distance to be cov- ered to allow for a trimmed fit. Fold back half ff SPEGDATA• and MANLLSPEC• are registered trademarks of Reed Elsevier Inc. The ten put SPEC -DATA famot oonfons to the e6farid style Reed Of The ConstRrhon Spedicatias Institute and s used with there permwon. The maeAachuer b respmbe fa technical acaxacy. 0"7 Reed Construction Data•. All Poghis Reserved. 42 Construction Data