Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-20-142
2. 0 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 JAN� INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201--T" UtA/� Master Permit No. Rc-01 — 2a _ I Sub Permit No. ROOFING REVISION ❑ EXTENSION RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP 1 ' • f 1 C CONTRACTOR DRAWINGS 0 JOB ADDRESS: \� 1vA'yy I 1 �-� City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Occupancy Type: Load: Construction Type: s the Building Historically Designated: Yes NO Flood Zone: . BFE: FFE: OWNER: Name (Fee Simple Titleholder): Phone#: Address: City: /YIlL?-/1'!f ?`Yl0/L�S State: Zip: 3,3/625 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: P061 ra /-A Phone#: Address: 110YO 1-5c / 61 1A011F 2� City: % Awe-Z State: VX ' Zip: 33317 Qualifier Name:Phone#: -30T s�i State Certification or Registration #: CC G /S10e450 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: �yy Value of Work for this Permit: $ !� �Q Sq are ' otage of Work: %�� �PA4 " Type of Work: ❑ Addition W Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Specify color of color thru tile: Submittal Fee $ - Scanning Fee $ Permit Fee $ Radon Fee $ ,;AO' Q fiC1tf;A✓ 4-4-31,0Vf�: 3 , Technology Fee $ Training/Education Fee $ Structural Reviews $ " 166. q (Revised02/24/2014) CCF $ DBPR $ CO/CC $ Notary $ Double Fee $ 1 . QN) Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and than all work will be done in compliance with all applicable laws regulating construction and zoning. J, "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In he absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature OWNER or AGENT CO ACTOR ` The foregoing instrume t was acknowledged before me this of dill 20 a0 , by who is personally known to me or who has produced T,/00 as identification and who did take an oath. NOTARY P Print: Seal: 1%mif-A PtRRAULT My C'OAAMISSION # G00891i EXPIRES February 02, 2021 The foregoing instrum nt fas acknowledged before me this d of 20 (/ , by 4 't o is personally known to m ho has produced as identification and who did tak ath. NOTARY PUBLIC Sign: int: yy,I ,I� �al:��,9tY PGp^;�, JYfAI&LE A(C4� 6MP 8ii8tow # 9 287860 o t�`y 8ff#�: fI oife§ Jan 1, 2023 4,M kF8 Jh NAti®nal Notary Assn. **ssr*************r**r*******r�* *******s*r:ssss***ss***•s***** APPROVED BY T� " Plans Examiner Structural Review Zoning Clerk (Revised02/24/2014) LlfTATION MAP 2. CODE INFORMATION WORK TO BE PERFORMED: INTERIOR ALTERATKNN KITCHEN RENOVATION ,JURISDICTION AUTHORITY OTY OF MAMI SHORES BUILDING DEPARTMENT APPLICABLE CODES RCOFtDA BU1t➢!NG ME, 2017 6tF E➢11ON ALL APc'uU3_E LOCAL AND %TA]E CODES, ORDINANCES AND REGULATIONS. NATiGNAL ELECTRIC M. NEC 20-17 FLORIDA FIRE PREVENTION CODE 2017. 6 Ih EDITION NATIONAL FIRE PREVENRON ASSOCIATION J. t rl"It-CAL IVUICJ CONSTRUCTION CLASSIFICATION: LEVEL 2 RECONFIGURATION OF SPACE ALTERATION -LEVEL 2 304.1 SCOPE i LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE AOOTION OR EUMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADONKANAL EQUIPMENT. THE SCOPE OF WORK FOR THIS PROJECT IS THE RECONFIGURING THE EAST BEDROOM, WALK-IN CLOSET. BATHROOM, EXISTING KITCHEN AND BURL NEW PARTITION WALLS AS SHOWN ON DRAWINGS. TYPE OF CONSTRUCTION: TYPE IIF.B.C. 601.2 TYPE I AND It CONSTRUCTION ARE THOSE TYPES OF CONSTRUCTION IN WHICH THE BUILDING ELEMENTS LISTED IN TABLE 601 OF THE TOD 2014 (CHPSECTION 601) ARE OF NONCOMBUSTIBLE MATERIALS. LEVEL. 11 ALTERATION DESCRIBED IN THESE DRAWINGS. TO BE IN CONFORMANCE WITH ALL REQUIREMENTS OF THE F.B.C. i ALL WORK, MATERULES AND EQUIPMENT UTILIZED IN THIS PROJECT SHALL BE I INSTAe i Fn IN STRICT ACCORDANCE WITH THE MANUFACTURES RFC0MMFNOAT1nNlS OWNER HAD REPLACED THE KITCHEN CABINETS AND ADDED A KITCHEN COUNTERTOP WITHOUT PERMIT. THESE PLANS REFLECT THE ASS -BUILT CONDITION OF THE KITCHEN AND THE ELECTRICAL UPGRADE WITH GFCI CUT PLUGS AND SMOKE DETECTORS. ALL THIS WORK WILL BE DONE BY A CERTIFIED ELECTRICAL AND GENERAL CONTRACTOR. EXISTING & DEMO FLOQR PLAN SCALE: 1 /4"=I'-O^ WALL LEGENn EXIST. WALLS TO REMAIN EXIST. PARTITION WALLS TO REMAIN EXIST. PARTI TION WALLS TO BE REMOVED _. EXIST. ITEMS TO BE REMOVED (DRYWALL TO BE REP ACED) EXIST. FLOORING TO BE REMOVED SYMBOL LEGEND �� EXIST. ELECTRIC PANEL TO REMAIN COUNG MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE, LIGHT SWITCH # EXIST OUTLET EXIST. CEILING MOUNTED FAN /LIGHT EXIST. EXHAUST FAN -s EXIST. ELECTRICAL WATER HEATER TO REMAIN AT SAME LOCATION EXIST. AIR HANDLER TO REMAIN AT SAME LOCATION SHORT CUTS E EXSTING TO REMAIN R EXISTING TO BE RELOCATED GFI GROUND FAULT INTERRUPT All ABOVE FINSHED FLOOR AFCI ARC FAULT CIRCUIT INTERRUPTERS I. NO MECHANICAL WORK WILL BE PERFORMED. PROPOSED ALTERATION DO NOT AFFECT FASTING CONDITIONS. 2_ ELECTRICAL OUTLETS. DEVICES AND SWITCHES LOCATED AT WORK AREAS to I RF rnygiNrrTrn P1' im rl rrmirm ni let ivirn INDi ALL SURFACE AFFECTED AT DEMOUDON SHALL BE PAINTED AND PATCHED OR! REPAIRED TO -AS NEW CONOMON. O u OO`MAL 0,Z5 S - REMCVE PORTION OF WALLS FOR NEW DOOR OPENING AS PEP, SHOWN. APROX. AR 80 S.F. -REMOVE ALL KITCHEN CABINETS AND APPLIANCE DEMOLITION NOTES 1. IMMEDIATELY REPORT TO ARCHITECT IF EXISTING CONDITIONS ARE DIFFERENTHA THAN SHOWN- 2 ' DISCONNECT WATER AND/ OR ANY OTHER UTILITIES PRIOR YO COMMENCING DEMOUTION, 3. CONTRACTOR SHALL PROTECT FROM DAMAGE ALL EXISTING FINISHES AND CONSTRUCTION NOT SCHEDULED FOR DEMOLITION. 4. CONTRACTOR SHALL PROVIDE DURING DEMOLITION OPERATIONS ALL SAFETY MEASURES AND FEATURES AS REQUIRED BY THE APPLICABLE CODES, RULES AND REGULATIONS HAVING JURISDICTION OVER. THE PROJECT. 5. ANY UTILITY LINES THAT ARE BROKEN OR DAMAGED DURING DEMOLITION OPERATIONS SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL CHARGE TO THE CONTRACT PRICE OR SHALL BE REPAIRED BY THE OWNER AT THE CONTRACTOR'S EXPENSE. B. ALL EXISTING TO REMAIN SURFACES SHALL BE PAINTED, PATCHED, AND/ OR REPAIRED TO AS NEW -CONDITION. 9. DEMOLITION SHALL BE PERFORMED BY A CREW EXPERIENCED IN SUCH WORK. 10. REMOVE AND CAP ALL PLUMBING WHERE SHOWN. IT. CUT AND PATCH FOR NEVI WORK AS NECESSARY. 12. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND/ OR INSTALLATION OF 14EW WORK AND/ OR UTILITIES, AS REQUIRED TO MATCH ADJACENT SURFACES AND / OR TO RECEIVE NEW SCHEDULED FINISHES. 13. COORDINATE WITH OWNER AS TO THE REMOVAL OF EXISTING FINISHES, FLOOR COVERING, LIGHT FIXTURES, SWITCHES, AND RECEPTACLES, PLUMBING FIXTURES, WALL FINISHES, ETC., PRIOR TO SUBMITTING BID, 14. THE ENTIRE SCOPE OF DEMOLITION REQUIRED TO PERFORM THE WORK MAY NOT BE SHOWN IN THESE PLANS. 15. CONTRACTOR SHALL PROVIDE ALL THE NECESSARY DEMOLITION TO ACHIEVE THE JOB HEREIN. 16. ANY PENETRATIONS OR ALTERATIONS TO EXISTING ROOF SYSTEMS SHALL BE FINISHED TO MATCH EXISTING. 17. REMOVE ALL DEBRIS FROM PROPERTY ON A TIMELY BASIS. DEBRIS SHALL NOT ACCUMULATE ON -SITE. 16. PROTECT WORKERS AND PUSUC FROM AREA OF DEMOLITION AT ALL TIMES. 19. CONTRACTOR SHALL EXERCISE EXTREME CARE WHEN PENETRATING EXISTING WALLS OR FLOOR. / CEILING SLABS SO STRUCTURAL INTEGRITY OF SUCH ELEMENTS IS NOT DEGRADED. CONTRACTOR SHALL RESTORE EXISTING SURFACES SCHEDULED TO REMAIN THAT ARE AFFECTED BY SCOPE OF WORK, CONTRACTOR SHALL SEAL TIGHT ALL NEW PENETRATIONS IN WALLS AND FLOOR CEILING SLABS TO PRESERVE THE REQUIRED FIRE RATING INTEGRITY. 20. EXISTING CONCERTED FLOOR SLABS AND/ OR SURFACES SHALL BE PREPARED TO RECEIVE NEW SCHEDULED FINISHES BY GRINDING, SCRAPING, FILLING, PATCHING, LEVELING, ETC, AS REQUIRED. z '3 H X rn z� a n r. -I ¢. LL a�r-I� Q' < -- z m U � 4� E Li m O w w = a _ U N � � t W o N Z z i r ;1 us Z W s• •'dg a •• S-i • • • I a t • II of • w i e Designed by SM --_—_ _ Drawn by JMAF Pnonr 181314_555 593- Ema,I luanmy27*gmail con 01.15.2020 rZ co U E co U 2. CODE INFORMATION il WORN TO BE PERFCRNED: INTERIOR ALTERATION KITCHEN RENOVATION JURISDICTION AUTHORITY CITY OF MIAMI SHORES BUILDING DEPAR MEN' APPUCABLE CODES FLORIDA BrOLD1NG CODE. 200 6lh EDITION AL AP?uIlAz E LOCAL AND S'A.TE COOTS. ORDINANCE`. A'ND FTGUTATONS. r WTKM4L ELECTRIC CODE. NEC 2017 FLOM FIRE PREVENINM CODE 2017. 6 1h EDITION NATIONAL FIRE PREVENTION ASSOCIATION FIRE SPRINKLERS NONE FIRE A ARM NONE ILTEPATION LEVEL II CONSTRUCTION CLASSIFICATION LEVEL 9 OCCUPANCY GROUP: R3 SINGLE FAMILY RESOEN kAL REHAB WORK CLASS ALTERATON 3. GENERAL NOTES CO NSTRUCTION C.ASSII'M_ATIOW LEVEL 2 RECONRGURAT1014 OF SPACE ALTERATION -LEVEL 2 304.1 SCOPE LEVEL 2 ALTERATIONS INCLUDE THE RECONFICUPATION OF SPACE, THE ADOMONN OR ELIMINATION OF ANY DOOR OR WINDOW. THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. TT1E SCOPE OF WORK FOR THIS PROJECT S THE RECONFIGURNG THE EX57 . 'WALK-IN CLOSET, BATHROOM. EXISTNG KITCHEN AND BUILD NEW ARTMON VIALS AS SHOWN ON DRAWINGS. f OF CONSTRUCTION: TYPE ILF.B.C. 6012 TYPE 1 AND 11 CONSTRUCTION ARE TYPES OF CONSTRUCTION IN WHICH THE BUI:.OING ELEMENTS LISTED IN ABLE 601 OF THE FBC 2014 (CHP.SECT*N 601) ARE OF NONCOMBUSTIBLE MATERIALS. II ALTERATION DESCRIBED IN T4ESE DRAWINGS. TO BE IN CONFORMANCE WITH REQUIREMENTS OF THE F.B.C. WORK, MATERIALES AND EQUIPMENT UTIUZED IN THIS PROJECT SHALL BE AILED IN STRICT ACCORDANCE WITH THE MANUFACTURES RECOMMENDATIONS 0 SPECIFICATIONS SCOPE OF WORK "AFTER THE FACT" PERMIT SUBMISSION FOR KITCHEN RENOVATION/ EW KITCHEN CABINETS AND APPLIANCES INSTALLATION) THIS PERMIT S TO LEGALIZED WORK AND OR 'NSTALLAT{ON MMENCED CONTRARY TO THE EQUIPMENTS OF THE ; A'ek o, t GARAGE FAWLY ROOM 9" , IY.ALL LEGEND w :.``► 1��O) EXIST WALLS TO REMAINa !2 EXIST. PARTITION WALLS TO REUN EXIST. PARTITION WALLS TO BE REMOVED� 0.' � 'S ZONING JCPJP.AL LLEECTRICAL i'LU/d31NG ECi-1AP.IU.L �� 1 l� t EXIST ITEMS TO BE REMOVED (DRY,YALL TO BE REPLACE �. S EXIST FLOORING TO BE REMOVED ` Q • 11 SYMBOL LEGEND gi-M EXIST ELECTRICVAIN PANEL TO REI1, tP�j C^ CEILING MOUNTED L:GHT FIXTURE s :OF� ��F� �O WALL MOUNTED LIGHT FIXTURE S I LIGHT SWITCH EXIST OUTLET ' EXIST. CEILING MOUNTED FAN /UGHT EXIST. EXHAUST FAN EXIST. ELECTRICAL WATER HEATER TO RDaIN AT SAME LOCATION AFTER -THE -FACT PERMIT. KITCHEN RENOATION, WORK DONE BUILDING PERMIT. KITCH'_N,VLOCATION O A ON ASI ' n PER SHOWN ON PLANS 4 � a cl-� AREA WORK / L I Ll f _' t t iiwdTi Fie, if 1 .} DINING RCQAt -rxq"; rt t r x t� E <. t - 3 KITCHEN i L-------________ ...HALL .. P.wZ' S0; _ OEM! �M 110 wo ,wwow 0otw+,c ao CLOSET l LONG ROOM FLosET BEDROOM �- 1t -4 N ,a 4." o BEDROOM CLOSET ENTRY e-- I IO'-.�- 1 10.-6.. EXISTINIIG & DEMO FLOOR PLAN SCALE: 1 /4"= l'-O" YNU EXIST. i4R HANDLER TO REVWN AT SAME LOCATION SHORT CUTS fr (� E EXISTIV, TO REMAIN Lt •' R EXS ING TO BE RELOCATED GFI GROUND FAULT INTERRUPT AF.F ABOVE FINISHED FLOWN AFCI ARC FAULT CIRCUIT INTERRUPTERS 1. P40 ME C:-IANFCAL WORK 61LL BE PERFORMED. PROPOSED ALTERATION Ca NOT AFFECT EXISTING CONDITIONS. 2. ELECTRICAL DJILETS. C MCES AND SWrCHES LOCATED AT WORK AREAS WILL BE DISCONNECTED BY AN ELECTRICAL OUAUFIEO. 3, PLJMBING FIXTURES SCHEDULE FOR DEMOLITION WILL BE PERFORMED BY ' A PLUMBING QUALIFIED NOTE: ALL SURFACE AFFECTED AT DEMLr.IT10N SHALL BE PAINTED AND PATCHED OR REPAIRED tG 'AS NEW CONDITION. DEMOLITION PLAN — REMOVE PORTION OF WALLS FOR NEW DOOR OPENING AS PER SHOWN. APROX AF 80 S.F. —REMOVE ALL KITCHEN CABINETS AND APPLIANCE DEMOLITION NOTES 1. IMMEDIATELY REPORT TO ARCHITECT IF EXISTING CONDITIONS ARE DIFFERENT THAN SHOWN 2, DISCONNECT WATER AND/ OR ANY OTHER UTILITIES PRIOR YO COMMENCING DEMOLITION. 3, CONTRACTOR SHALL PROTECT FROM DAMAGE ALL EXISTING FINISHES AND CONSTRUCTION NOT SCHEDULED FOR DEMOLITION. .4. CONTRACTOR SHALL PROVIDE DURING DEMOLTION OPERATIONS ALL SAFETY' MEASURES AND FEATURES AS REQUIRED BY THE APPLICABLE CODES. RULES ANC REGULATIONS HAVING JURISDICTION OVER THE PROJECT. 5. ANY UTILITY LIMES THAT ARE BROKEN OR DAMAGED DURING DEMOLITION OPERATIONS SHALL BE REPAIRED BY THE CONTRACTOR AT NO ADDITIONAL CHARGE TO THE CONTRACT PRICE OR SHALL BE REPAIRED BY THE OWNER AT THE , CONTRACTOR'S EXPENSE- 8. ALL EXISTING TO REMAIN SURFACES SHALL BE PAINTED. PATCHED, AND/ OR REPAIRED TO -AS NElY CONOI T,ON. 9. DEMOLITION SHALL BE PERFORMED BY A CREW EXPERIENCED IN SUCH WORK. 10. REMOVE AND CAP .ALL PLUMBING WHERE SHOWN. 0 11. CUT AND PATCH FOR NEW WORK AS NECESSARY. 12. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION ANDI OR INSTALLATION OF NEW WORK AND/ OR UTILITIES, AS REOUIRED TO MATCH ADJACENT SURFACES AND / OR TO RECEIVE NEW SCHEDULED FINISHES. 13. COORDINATE WITH OWNER AS TO THE REMOVAL OF EXISTING FINISHES, FLOOR COVERING, LIGHT FIXTURES, SWITCHES, AND RECEPTACLES. PLUMBING FIXTURES. WALL FINISHES, ETC., PRIOR TO SUBMITTING BID. 14. THE ENTIRE SCOPE OF DEMOLITION REQUIRED TO PERFORM THE NOT BE SHOWN IN THESE PLANS. 15. CONTRACTOR SHALL PROVIDE ALL THE NECESSARY DEMOLITION' JOB HEREIN. 16. ANY PENETRATIONS OR ALTERATIONS TO EXISTING ROOF SYS• FINISHED TO MATCH EXISTING �Z d F- 'u) m — X cD I o m z z ..-1 0 0 .-` z _j rJ;O o >- 65 ,I V E i; LL co z = U Lu w a — w L Y `Iz 3 I� z I� z I w 0 • • �•; • Designed ty S M. j J.MAF 17. REMOVE ALL DEBRIS FROM PROPERTY ON A TIMELY BASIS. o ACCUMULATE ON -SITE. - 18. PROTECT WORKERS AND PUBLIC FROM AREA OF OEMOLITII 19. CONTRACTOR SHALL EXERCISE EXTREME CAPE WHEN PEN ool WALLS OR FLOOR / CEILING SLABS SG STRUCTURAL INTEGR' ti IS NOT DEGRADED. CONTRACTOR SHALL RESTORE EXISTING SCHEDULED TO REMAIN THAT ARE AFFECTED BY SCOPE OF SHALL SEAL TIGHT ALL NEW PENETRATIONS IN WALLS AND �' A TO PRESERVE THE REQUIRED FIRE RATING INTEGRITY. J' 20. EXISTING CONCERTED FLOOR SLABS AND/ OR SURFD RECEIVE NEW SCHEDULED FINISHES BY GRINDING, SCRAP LEVELING. ETC. AS REQUIRED. PROPOSED KITCHEN PLAN SCALE: �/8"=1'-C' »wnv n:• m.mC b � m+ux svo +roata. lain. v Ira,,; M1.0, LW 2r sHr xr. uq. aNx � Ir oc as f(ON21D b a.Oln 1N - cant nou rw, va aAu, vua scan. K* t -,RYWALL PARTITION WALL/ RATED WALL REPARATION .NOTES: - WALL KIND: Y*GIPSUM BOARD -'WALL BCjJ* 5f8 'GYPSJM BOARD TYPE X FOR FIRE RATED - FASTER TYPE: SCREW MIN, I S '1 16- -SCREWS SHALL BE DRIVEN SO THAT SOO HEADS ME SIGHTLY BELLOW THE PANEL 'SURFACE WrI-M MAKING THE FACE PAPER, fRACTURING THE: CORE OR ,W, PNG THE FRAONG MEMBER MOUND THE SCREW SHANK ALL SURFACE AFFECTED SHALL BE PAINTED. PATCHEC• OR REPAIRED TO -AS NEW COND 110%, ALL NEW FINISH (WALL/ CDLND/ FLOO?/ MM/ DECOR), SHOAL COMPLY WITH ,BC8 O T7 8. FOR PJ41E SPREAD AND SMOKE DEMOPMDIT CLASSMAT04. CO NCFE'E RJIX ICL. n — SHEETRY,.K 4R COIF SCOPE OF WORK 1. KITCHEN A FTER -THE -FACT pQW. KITCHEN - NEW KITCHEN COUNTER ATION, WCM( DONE 'WITHOUT A -NEV CABINETS INSTALLATION W PERMIT. KITCHEN LOCATION -HEW APPLIANCES INSTALLATION -NEW LAMINATE FLOORING 14STALLATION SHOWN ON PLANS WALL LEGEND 'dl EXIST. WALLS TO REMAIN •:x', EXIST. PARTITION WALLS TO REMAIN SYUBOL LEGEND O EXIST. ELECTRIC PANG. © EXIST. ELECTRICAL WATER HEATER TO REMAIN AT SAME LOCATION EXIST. AIR HANDLER TO REMAIN AT SAME LOCATION p, WAGE DETECTOR, CUM MOUNTED, 120 VOLTS WITH VISIBLE POWER OF INDICATOR, TEST BLTTON AND SELF-CONTAINED. SOUNDING DEVICE (MN. RATING 85 DBA .AT IT-61 j HM WIRED, CARBON MONOXIDE DETECTORS. WITH BATTERY BACKUP MUST BE INTERCONNECTED so ALL DETECTORS SOUND WHEN ANY DETECTORS IS ACTRATED. SHORT CUTS E - DSTING TO R.DAAN R - DIM TO BE RELOCATED GFI - GROUND FAAILT NTERRLIPTOR. AF.F - ABOVE FINISHED FLOOR AFCI ARC FAULT CIRCUIT INTERRUPTERS NOTE _ _ I ONO MECHANICAL WORK WILL BE PERFORMED. PROPOSED ALTERATION CO NOT AFFECT I EXISTING CONDITIONS D ELECTRICAL OUTLETS LACES AND SWITCHES LOCATED AT 'WORK ARDS WILL BE DISCONNECTED BY AN ELECTRICAL QUALIFIED. ALL PLUMBING RXTIANES AT KITCHEN TO REMAIN AT SAME LOCATKN, j GENERAL CONTRACTOR AND SUB -CONTRACTOR NOTES 1. EACH CONTRACTOR AND SU9CONTRACTOR SHALL VISIT THE SITE AND EDSTING FACILITIES TO DETERMINE THE EXTENT OF WORK. IT SHAH. BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY EXISTING CONDITION AND TO MAKE ALLOWANCE FOR THEM PRIOR TO ANY COISIRUCTKJN• 2 ALL WORK DONE UNDER THE SUPOMSION OF THE CONTRACTOR SHALL BE IN A NEAT AID WORKMANLIKE MANNER AND IN ACCORDANCE WITH ALL ZJOHHING AGENCIES. RULES AND REGULATIONS HAVING JURISDDTiON, 3. ALL PK UCTS SHALL BE INSTALLED PEP MANUFAC'TU4ERS R.FCOUMENOADO"S 4. EACH CONTRACTOR AND SUBL1 4RACCTO.4 SHALL BE RESPONSIBLE FOR THE SJETr AND WELL-BEING OF HIS EMPLOYEES AND ALL CONSTRUCTION SAFETY REGULATIONS INCLUDING OSHA ARE TO BE STRICTLY FOLLOWED. 5. THE CCNTRACTOR SHALL REPAIR AND PANT EXISTING SURFACES OAMAGED BY DEMC4f0QN COVERED WITCHING THE COHM49 DOCUMENTS, 5, THE CONTRACTOR SHALL COORDINATE AND SCItEDULE THE WORK OF ALL TRADES TO INSURE THE WORK IS COMPLETED IN A TIMELY MANNER, COMPLYING WITH THE OVER / CONTRACTOR AC,PIEBAENT. 7. THE CONTRACTOR SHALL PRONDE AN ON SITE DUUPSTER IN A LOCATION APPROVED BY THE OWNER FOR THE DISPOSAL OF REMOVED LIATER4AL 8. GENERAL CONTPXTOR SHALL SUBMIT A SCHEME SHOWING TIME OF DAY AREA AND MEANS OF TRAVEL THROUGH PREMISES FOR DISPOSAL OF DEBRIS FOR OWNER APPROVAL NOTE: THE COINTAACTDR SHALL PROVJE AN ITEMIZED COST OF BREAKDOWN OF ALL ITEMS AND PHASES Of CONSTRUC'gN AT THE TIME OF BIDDING. ELECTRICALSCOPE -KITCHEN GFCI PROTECTED RECEPTACLE OUTLETS -RELOCATE EXISTING LIGHT SWITCH AS PER SHOWN ON PLANS - SMOKE DETECTORS INSTALLATION, IF NECESSARY ELECTRICAL Y:Ge c RA 'C S - ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC 2014). FLORIDA BUILDING CODE (FBC 2017, 6Lh EDTTION) AND ALL OTHER APPLICABLE CODES, AND ORDINANCES IN EFFECT AT THIS LOCATION. -VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING WORK. OUTLETS SHALL BE FLUSHED WITH FINISHED SURFACES, TWO OP. MORE LIGHT SWITCHES IN SAME V.ALL SHALL BE INSTALLED IN CANG -TYPE BOXES. -WIRING DEVICES BE APPROVED RESIDENTIAi_ GRADE. VERIFY LOCATION PRIOR TO ROUGH -IN. TYPES SHALL BE AS SELECTED BY THE ARCHITECT, THE OWNER, AND / OR THE INTERIOR DESIGNER. -JUNCTION BOXES SHALL BE GALVANIZED STEEL WITH SCREW OR HINGED COVERS FOR FURNISH AND INSTALL ALL LIGHTING FIXTURES WITH LAMPS. TYPES SHALL BE AS SELECTED BY THE ARCHITECT, THE OWNER, AND / OR THE INTERIOR DESIGNER. - ALL MATERIAL SHALL BE NEW AND COMPLY WITH THE NATIONAL ELECTRICAL CODE. -ELECTRICAL CONTRACTOR SHALL PERFOR14 ALL NECESSARY WORK FOR A COMPLETE ELECTRICAL INSTALLATION AND SHALL PROVIDE ALL NECESSARY INSTRUMENTS AND SPECIAL APPARATUS TO CONDUCT ANY TEST THAT MAY BE REQUIRED TO INSURE THE SYSTEM IS FREE OF ALL IMPROPER GROUNDS AND SHORT CIRCUITS, AND THAT ALL FEEDERS ARE PROPERLY BALANCED, WALL I FGFN11 EXIST. FIRE RATED VIOLIST C! tEv:"T"#.L EXIST. PARTITION WALLS ALL 1 I) n PLIAN E C . LF �niED d iS ELEC, SYMBOL LEGEND SYMBOL AND DESCRIPTION IC RATED RECESSED DOWNLIGHTS, LED LIGHT FIXTURE, RECESSED MOUNTED WITH SOLID LENS. SINGLE POLE LIGHT SAITCH, OUIET -TYPE, 120 VOLTS, 20 AMPS, FOR OT DOOR AND DISPOSAL CIRCUITS, 15 AMPS ELSEWHERE. INSTALL 48-A.F.F. i DUPLEX RECEPTACLE OUTLET, 125 VOLTS, 3 -'WIRE, GROUNCING TYPE, 20 AMPSFOR APPLIANCES CKTS, 15 AMPS ELSEWHERE. INSTALL 18-A.F.F UNLESS OTHERWISE INDICATED. SPECIAL RECEPTACLE OUTLET, 240 `MOLTS, SINGLE PHASE, 4 -WIRE, GROUNDING TYPE. INSTALL I8'A.F.F. UNLESS OTHERWISE INDICATED. RECEPTACLE OUT ET. Isa"ua.TS, 3 -VARE. GROUNDING TYPE, 20 AMPS FOR APPLIANCES Clcrs..15 AMPS ELSEWHERE, INSTALL 48-A.F.F. UNLESS OTHER'.V'RSE INDICATED. PROVIDE GFC+. DUPLEX RECEPTACLE OUTLET, 125 VOLTS, 3 -WIRE, GROUNDING TYPE, 20 AMPS. GROUND FAULT INTERRUPTER TYPE (GFCI), ARC FAULT CIRCLIT INTERRUPTERS TYPE 11 (AFCI), TELEPHONE OUTLET. INSTALL 18-A.F.F_ UNLESS OTHERWISE INDICATED. N SMOKE DETECTOR, CEILING MOUNTED, 120 VOLTS WITH VISIBLE POWER 'ON - INDICATOR, TEST BUTTON AND SELF -CONTAINED, SOUNDING DEVICE (MIN. SD% RATING 85 DBA AT 10' - 7). HARD WIRED CARBON MONOXIDE DETECTORS, WITH BATTERY BACKUP MUST BE INTERCONNECTED SO ALL DETECTORS SOUND WHEN ANY ANY DETECTOR IS ACTIVATED. SHORT CUTS E EXISTING TO REMAIN R EXISTING TO BE RELOCATED GFI GROUND FAULT INTERRUPTER A.F.F rL80VE FINISHED FLOOR AFCI ARC FAULT CIRCUIT INTERRUPTERS l- fA Idl Jams Is= 1f r Ism rAVX N SIDE SIDE rrr — yJ— -' " -__ BACKING FOR CABINETS DETAILS - BACKiN; FOR CABINETS DETAILS (AT METAL STUD WALLS) BACKING FOR CABINETS DETAILS (AT CBS WALLS) ELEVATION (AT KIETRL STUD WALLS) PLAN VIEh B-B LU a I I LPIH 1!//OF- :'fl •• � "j0'r.' ICI PROPOSED ELECTRICAL PLAN � SCALE: NOTES: - All KITCHEN RECEPTACLE OUTLETS MUST BE LISTED AFCI AND GFCI COMBINATION PROTECTION. FBC 10425.1/FBC 107.3.5 (8)/ MC 210,9/ 210,12 -TAMPER RESISTANT RECEPTACLES IN DWELLING UNIS, N VERY Krl"L FAMILY ROOM, DINNING ROOM, UAW ROOM, PARLOR, LDPAR(. DEN, SUNP.000, BECROOU, RECREATION ROOM, BATHROOM. GARAGE, WEMENI. LAINORY, AD OUTDOOR mAEk ALL 125 -VOLT. 15 -AND 20 -AMPERE RECEPRA_LE SHALL BE LISTED TAMPER RESISTANT RECEPTACLES. -OUTLETS OSPOSEP GFCI, (Si.NK5: NEC -2014 ART, -210.3 (A)(7): GFG PROTECTION FOR PERS OEL ALL RECEPTACLE-- ARE INSTALLED WITHIN (6FT) Of THE OUTSIDE EVA OF SINK. -OUTLETS KITO!BN DISHWASHER GFCI, (DWELLING TWITS BRANCH CIRCUIT: NEC - 2014 ART. -210.8 (0): GFCI PROTECTION FOR PERSONIIEL SHIN. BE PRONDED FOR - OUTLETS THAT SUPPLY DISHWASHERS INSTALLED N D%nLm UNIT LoCATROvs. Z g a J Co Q � U � ' H J LU Z -' _J polo 0 O? Z WZ='5 Z I_ w � W _ -! 0 o `1 Y W Z _ 0 a 0 a -OUTLETS LAUNDRY GFCI, (LAUNDRY AREAS: NEC -2014 ART. -210.8 (10): GFCI :. E PROTECTON FOR PERSONNEL: ALL 125 -KILT, SINGLE PHASE. 15 & 20 WEE • • • • RECEPTACLES SHALL HAVE GFCI, NSTALLEO IN LAUNDRY ROOM. • • • • • • • • 0000 0000 -- ••••�••s' ••• • N AAA a • • 7 r antra w.? w na ccTAu .1... I. SMOKE DETECTOR WIRING SHALL BE MADE SO THAT ONE IS ACTIVATED, THE REST S SHALL BE ACTUATED. 2 ALL SMOKE DETECTORS SHALL BE AFCI PROTECTED. 3. SMOKE DETECTOR SHOULD 13E PLACED AT LEO VFROM ANY CORNER WALL UINCi1ON. 4, SMOKE DETECTOR SHOULD NOT BE PLAC A) CLOSER THAN 3 FEET FROM AN AIR SUPPLY DIFFl1SER OR AN AIR VENT, B) CLOSER THAN I FEET FROM FUJDRESCENT LIGHT FIXTURE s�.oa,•ina-�.' .. Ana any /i -u[ m o aIa pn- n.eA moca NOTE: % z OcEECI R sul BE wz%IRED (I lov TYPE) TO A NON- SNITCH Aar KITCHEN OR E>4TFCKlw LIGHTING CIRCUIT, PATH BATTER! BAD: -UP AND 514U NOT RECONNECTED ONTO THE L04O SIDE OF GROUND FAULT CIRCUIT NTEFRUPTERJLL -SD ` DFTC,TOP WITHIN EACH UNIT SHALL BE INTE kOMECTED. 000.00 • u • • • a •' • •• • Da%QneU by. ..00, S.M ) JAIAP Pnone: (9131455 SSM Email IwuvnyZ7Aynalzom 01.15.2020 .Pr� Nc. ___ si »w����r� ` un�u��ncn� --uus" dnooZ °_ °°°° ° \ nooy ox�c ``. 6] _�S/K] ' GARAGE BATH. =.AMILY ROOM PANEL SCHEDULE. PANEL SCHEDULE. 1 2 RANGE rn o WATER HEATER 3 4 RANGE CONDENSED UNIT 5 6 REFRIGERATOR j CONDENSED UNIT 7 6 BEDROOM AIR HANDLER 9 10 BEDROOM AIR HANDLER 11 12 WASHER SMALL APPLIANCE 13 14 DINING & LIVING I`40TE: F SMALL APPLIANCE 15 16 I Dedicated circuits for BATHROOM1 17 18 Small appliance and = ' BATHROOM #2 19 20 I rem Are o g, tor. GFI protc . trd EXIST E.P. �. Pantry DINING ROOM }} " KITCHEN GFl Re` HALL s CLCF=T I LIVING ROOM CLOSET 4 "" BEDROOM ENTRY :CLOSET PROPOSED ELECTRICAL PLAN SCALE: 5/8"=1 '-0" AD CALCULATION LUC PIERRE 1684 SOFT OF LIVING X 3 VA 5,052 3 SMALL APPLIANCE CIRCUITS (DINING RM) 4.500 WASHER 1.500 RANGE 5.000 REFRIGERAI"DR 1.500 DISH WASHER 1.200 DISPOSAL 800 MICROWAVE 1.200 DRYER 6,000 W/H 5,000 ------------ GENERAL TOTAL 35,752 WATTS FIRST ....1007 10,000 WATTS REMAINDER WATTS ... 407 10,301 WATTS GENERAL LIGHTING TOTAL DEMAND 20,301 WATTS A/C ..4 HEATER _ 10-000 1vA7•15—� TCTAL DEMAND IN KWATTS 30.301 TOTAL DEMAND IN AMPS 132 WEATHER HEAD INSTALLED 12 FEET OF THE FLOOR -TWO INCH RIDGID RISER 3-2/OTHWN COPPER < AMP METER COMBO 29CIRCUITA I D00 AMP MAIN REAKER V^I W $I IIr a �11 �_1AL& ca v INAL y41i' C3 m 3 a " U _. P iE in Q ����111 0 W m uJ M O U o = 0 EL n. z 10 • • a • • 0 • © / JYAF on• (E13) ass sacra ErnM 0f.M11 Oft. a,ns,zmo P"-a No E1 GARAGE �_ Wr BATH. PANEL SCHEDULE Water heater 1 2 Range Water heater 3 4 Range Condensed unit 5 6 Fridge (GF1 protection) Condensed unit 7 8 Bedroom Air handler 9 10 Bedroom Airhandler 11 12 Bedroom Small appliance IGFl protection) 13 14 Washer Small appliance (GFI protection) , 15 16 Dining d living Battroorn n 1 17 18 Lights Bathroom 02 J 14 20 T.; EXIST E.P. E CU 4' - L CKT 18 Pantry G CKT`.t CKT #1 DINING ROOM E E I . ,I •: FAMILY ROOM` cr<T q6 EXISTING LIGHTING I v E r. Y CFI CKT 17 LIVII bUALL: 5/6 = I —U gf LIK;).JI:4 AD CALCULATLO-N LUC PIERRE 1684 SOFT OF LIVING X 3 VA 5,052 3 SMALL APPLIANCE CIRCUITS (DINING RM) 4.500 WASHER 1,500 RANGE 8,000 REFRIGERATOR 1.500 DISH WASHER 1.200 DISPOSAL 800 MICROWAVE 1,200 DRYER 6,000 Wr% H 5.000 GENERAL TOTAL ------------ 35,752 41A7i-lS FIRST ....100% 10,000 WATTS REMAINDER WATTS ... 40% 10,301 WATTS GENERAL LIGHTING TOTAL DEMAND 20,301 WATTS A/C & HEATER - 10,000 WATTS TOTAL DEMAND IN K?;ATTS 30.301 TOTAL DEMAND IN AMPS 132 WEATHER HEAD INSTALLED 12 FEET OF THE FLOOR -TWO INCH RIDGID RISER 3-2/OTHWN COPPER f� ,200 AMP MAIN BREAKER BREAKER I --tf4 SOLID COPPER FROM MAIN TO A COLD WATER LINE TWO GROUNDING ELECTRODES U E Cu ET L ti' `' rl ttl+l'1 W m C� g J V m O O cap o 1 <C W Q m 0 Z O Oo a z _ *see ti • d • . •).w w..•w• a • • 10.000 ..•. •..•ww •• •00 • w• • w•w•. • • w • '•••!.• •.• . • • •w••• a • •. .• w• ••.•.. •..w•• .• • ...a • • a i •.w• Ix Designod by S.M. Dnt by. JJJAF. Phone: Ernall (813) 455 5934 )uamhl,27@w-w9— Dn.vp Data. 07-15�020 project No. Sneel N. El