Loading...
EL-20-255Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 02/11/2020 Location Address Parcel Number 274 NW 93RD ST, Miami Shores, FL 33150 1131010331120 Permit o.: EL-02-20-255 Permit Type: Electrical - Residential Work Ctossifrcotion: Alteration Permit5totus: Approved Expiration: 08/10/2020 MATTHEW CITRIGLIA Owner SHINE ELECTRICAL ENGINEERING Contractor 274 FRANCISCO SANTOS 3876 NW 125 STREET 125 Street, OPA LOCKA, FL 33054 Business: 3056882000 ahuezo@shinneelectric.com Description: CONVERT FPL SERVICE FROM OVER HEAD TO Valuation: $ 2,183.00 Inspection Requests: 305-762-4949 UNDERGROUND TotalSq Feet: 0.00 mj Fees Amount Application Fee - Other $50.00 CCF $1.80 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.60 Permit Fee $50.00 Scanning Fee $9.00 Technology Fee $2.50 Total: $117.90 Payments Date Paid Amt Paid Total Fees $117.90 Credit Card 02/11/2020 $67.90 Credit Card 02/05/2020 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing infTqation is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhhermo , I authoriz t above named contractor to do the work stated. 1 ./igt4 j �- 20 ;? O Authorized Signature: Owner / Appltca / Contracto/ // Agent February 11, 2020 Date Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION []BUILDING 0 ELECTRIC ❑ ROOFING ENTERED FEB 0 5 20n BY: FBC 201-q 0�" Master Permit No. F.L'o`Z- 20 -�255 Sub Permit No. ❑ REVISION ❑ EXTENSION RENEWAL ❑PLUMBING [:]MECHANICAL ❑PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 274 NW 93 STREET City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11-3101-033-1120 Is the Building Historically Designated: Yes NO Occupancy Type: Residential Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): MATTHEW A. CITRIGLIA / JUDITH GOLDSTEIN phone#: 614-439-7468 Address: 274 NW 93 STREET City: MIAMI SHORES State: FL Zip: 33150 Tenant/Lessee Name: N/A Phone#: Email: MATTHEW.CITRIGLIA@SGWS.COM CONTRACTOR: Company Name: SHINE ELECTRICAL ENGINEERING Phone#: 305-688-2000 Address: 3876 NW 125 STREET City: OPA LOCKA State: FL Zip: 33054 Qualifier Name: FRANCISCO E. SANTOS Phone#: 305-688-2000 State Certification or Registration #: ECO001514 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ •?.,i $3.00 Square/Linear Footage of Work: Type of Work: ❑ Addition Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: CONVERT FPL SERVICE FROM OVERHEAD TO UNDERGROUND. Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ '510 (Revised02/24/2014) Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zi Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7),fi6ys after the building permit is issued. In the absence of such posted notice, the inspection will not be apprpuedau2d—d`r0inspe ion fee will be charged. Signatu AGENT The foregoing instrument was acknowledged before me this day of K W of , 20 aQ by Q-��1 �� C,►->' �i, )1 Gi_, who is personally known to me or who has produced If b-'Ida �(Wy i (C 2tfS�' as identification and who did take an oath. NOTARY PUBLIC: Sign:_ Print: Signature CONTRACTOR The foSegoing instrument was acknowledged before me this i1 day of 'Fd 0oruct 20 Zo by Tfan t6SCO E• SCAn S , who is ersonaliy known to me or who has produced as identification and who did tak��tt;�rgt�- Anisley HUeZo NOTARY P C: _ ���� Commission # FF976254 "�•,'�= Expires: June 24, 2020 Bonded thru Aaron Notary Seal: p1p0.Y P"B(��i IVONNE LANDERO Se ?► �:°�: Notary Public - State of Florida N' do Commission # GG 006859 My Comm. Expires Jun 28, 2020 4n APPROVED By �s Examiner (Revised02/24/2014) ################################################ Structural Review Zoning Clerk Summary Report Property Information Folio: 11-3101-033-1120 Property Address: 274 NW 93 ST Miami Shores, FL 33150-2236 Owner MATTHEW A CITRIGLIA JUDITH GOLDSTEIN Mailing Address 274 NW 93 ST MIAMI SHORES, FL 33150 USA PA Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 1,839 Sq.Ft Living Area 1,807 Sq.Ft Adjusted Area 1,559 Sq.Ft Lot Size 9,225 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 2019 2018 2017 Land Value $212,839 $203,198 $203,198 Building Value $198,149 $161,746 $90,391 XF Value $2,208 $2,236 $2,264 Market Value $413,196 $367,180 $295,853 Assessed Value 1 $413,196 $367,180 $292,904 Benefits Information Benefit Type 2019 2018 2017 Non -Homestead Cap Assessment Reduction $2,949 Homestead Exemption $25,000 Second Homestead Exemption $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 6 PB 10-39 LOT 10 & E1/2 LOT 11 BLK 135 LOT SIZE 75.000 X 123 OR 17931-1503 1297 1 COC 21894-3158 11 2003 4 Generated On : 1/22/2020 Taxable Value Information 2019 2018 2017 County Exemption Value $50,000 $0 $0 Taxable Value 1 $363,1961 $367,180 $292,904 School Board Exemption Value $25,000 $0 $0 Taxable Value 1 $388,196 $367,180 $295,853 City Exemption Value $50,000 $0 $0 Taxable Value 1 $363,196 $367,180 $292,904 Regional Exemption Value $50,000 $0 $0 Taxable Value 1 $363,196 $367,1801 $292,904 Sales Information Previous Price O Book- Qualification Description Sale Page 10/21/2019 $100 31674-1436 Corrective, tax or QCD; min consideration 04/30/2018 $535,000 30967-3807 Qual by exam of deed 07/21/2014 $242,369 29246-2936 Qual by verifiable & documented evidence Financial inst or "In Lieu of Forclosure" 07/16/2013 $225,100 28928-3624 stated The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: JOB: MATTHElit1E A_ CITRI+GLIA `' SHINE ELECTRICAL ENGINEERING Master Electrician: FRANCISCO E SANTOS 274 NW 93rd STREET 3876 NVV 125 ST Signature: MIAMI SHORES,FL_33 OPA LOCKA,FL.33054 EC 0001514 Notar , , .. ,vim Anisley Huezo = ommission # FF976254 ExpiresJune 24, 2020 SCOPE OF WORK: CONVERT FPL S FROM OVERHEAD TO UNDERGROUND. a�a� �' Bonded* thru Aaron Notary "EXISTING ELECTRICAL RISER" OUTSIDE 111SIDE EXISTING METER EXISTING PANEL COMBO 200AMP 200 AMR j { �' L"02"70"�S 3-#210 THHNITHN Cu. — tit Vi ne AP[ ROB J SY DA ZONIN 5L r)G DEOT SUBJECT �O Cc;nl�llt`r.CF wl FH All FEUERAL SL ATE A"Jo UC I jN ( -iUL C! :_l-" ` r�'dS "NEW ELECTRICAL RISER DIAGRAIUf :...• ...... OUTSIDE .. JIWDE • • . • • ; • •••••• • .... .... . . • • • EXISTING METER � KgItTING-PAM � • • • • ••2U0 AMP •• •••••• COMBO 200AMP • • • • • • • • . . .. . ...... 0 200 A INTERSYSTEM BONDING- EXISTING 34210 THHNifHVgN Cu. IN 112" C. JEW # 4 Cu. (EGC) vvCP 518 GROUND & APART MINIMUN JOB: MATTHEW A. CITRIGLIA 274 NW 93rd STREET MIAMI SHORES,FL.33150 EXISTING HOUSE PANEL COLUMN 1 (CALCULATING EXISTING + NEW LOADS) NEC 220.82 OPTIONAL FOR DWELLING UNIT STEP 1 : General Lighting Load NEC 220.82 Existing Residence Square Footage 1 1 1780 1 x 3 WATTS / Sq. Ft. 5340 WATTS TOTAL STEP 1: = 5340 WATTS STEP 2 Small Appliance and Laundry load. Small Appliance Ckts. 2 X 1500 WATTS = 3000 WATTS Laundry Ckt. 1 X 1500 WATTS = 1500 WATTS TOTAL STEP 2: = 4S00 WATTS STEP 3 : Existing load NEC 220.82.Plus Range 0 X 0 WATTS = 0 WATTS Refrigerator 3 X 3000 WATTS = 3000 WATTS Dishwasher 1 X 1200 WATTS = 1200 WATTS Disposal 1 X 800 WATTS = 800 WATTS Oven 1 X 6000 WATTS = 6000 WATTS Microwave 1 X 1600 WATTS = 1600 WATTS Washer 1 X 1200 WATTS = 1200 WATTS Dryer 1 X 5000 WATTS = 5000 WATTS S rinker-Pum s 1 X 1920 WATTS = 1920 WATTS Water -Heaters 1 X 4500 WATTS = 4500 WATTS Jacum 0 X 0 WATTS = 0 WATTS Cook Top 1 X 6000 WATTS = 6000 WATTS Car Charger 0 X 0 WATTS = 0 WATTS RV Outlets 0 X 0 WATTS = 0 WATTS CHLORINATOR 0 X 0 WATTS = 0 1 WATTS POOL LIGHTS 0 X 0 WATTS = 0 1 WATTS NICHELESS 0 X 0 WATTS = 0 WATTS LED BUBBLER 0 X 0 WATTS = 0 WATTS " SPA LIGHTS 0 X 0 WATTS = 0 WATTS 240V FILTER PUMP 0 X 0 WATTS = 0 WATTS 240V BLOWER PUMP 0 X 0 WATTS = 0 WATTS 240V EXTRA PUMP t----o-1 X 0 WATTS = 0 WATTS TOTAL STEP 3: = 31220 WATTS SUBTOTAL : ( STEP 1 + STEP 2 + STEP 3) : = 41060 WATTS STEP 4 Applying Demand Load Table NEC 220.82 FIRST 8000 WATTS 100%, 8000 WATTS REMAINDER 41060 - 8000 = 33060 IWATTS @ 40% 13224 WATTS COLUMN 1 Total Load: = 21224 WATTS COLUMN 2 LARGEST LOAD BETWEEN HEATING AND A/C LOAD. STEP 5 : Selecting Largest Load NEC 220.82 A/C # 1 HeatLoad 100%, 1 1 1 X 10000 = 100001 WATTS A/C #2 & 3 HeatLoad100%, 1 0 L X 1 0 = 01 WATTS HEAT PUMP 100% 1 0 1 X 1 0 = 0 WATTS COLUMN 2 Total Load : = 10000 WATTS TOTALING LOADS: ( COLUMN 1 + COLUMN 2) = 31224 WATTS FINDING AMPS FOR PHASES I = WATTS I V. = 130 AMPS. EXISTING ELECTRICAL SERVICE ( AMPS) 200 YES ADEQUATE FOR NEW LOAD. SHINE ELECTRICAL ENGINEERING 3876 NW 125 ST. OPA-LOCKA,FL.33054 (EC0001514) TEL:305-688-2000 Master Electri 'MCI SANTOS Si nature: Nota : Anisley Hum • �e�'¢�b��'� Cnai ss oo # FF9M54 `., Expires: June 24, 2020 % o�I. IR .� Bunded thru Aaron Notary r