RF-20-505R�-o3-z�-,5os
Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
P( � Ff I U- b�b 11 1�
Issue Date: 03/12/2020
Location Address Parcel Number
1019 NE 104TH ST, Miami Shores, FL 33138 1122320290130
rnnrarrc
Permit NO.: RF-03-20-505
Permit Type: Roof
Work Classification: Tile
Permit Status: Approved
Expiration: 09/02/2020
James Alvah Owner
1019 NE 104 ST
C & G PROFESSIONAL CONSTRACTORS Contractor
INC
JUAN CARLOS CATA
9254 NW 120 TER, HIALEAH, FL 33018
Business: 3055270581 CGCONTRACTORINC@AOL.COM
Description: TILE RE -ROOF Valuation: $ 30,000.00 Inspection Requests:
49
Total Sq Feet: 3,200.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$18.00
DBPR Fee
$4.88
DCA Fee
$3.25
Education Surcharge
$6.00
Roofing Fee
$275.00
Scanning Fee
$12.00
Technology Fee
$8.13
Total:
$377.26
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$377.26
Credit Card
03/06/2020 $50.00
Credit Card
03/12/2020 $327.26
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating construction and zoning. Futhermore, I authoriz above named contractor to do the work stated.
-__- 0'k,/�/�)
Authorized Signature: Owner
/ Applicant / -Co-'n'fWctor / Agent
Date
March 12, 2020 Page 2 of 2
PERMIT APPLICATION
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762.4949
Master Permit No.
Sub Permit No.
R-ECEIVED
MA A 0 6 2020
BY:
FBC 20
[]BUILDING ELECTRIC ROOFING REVISION EXTENSION ORENEWAL
CJPLUMBING [3 MECHANICAL RUBUC WORKS CHANGt OF CANCELLATION SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 10 19 N F, 104 St.
gily: - - , ". 'Miami Shores
Folio/Parcel#- 11-2232-029-0130 Is the Building Historically Designatedt Yes NOX
Occupancy Type: Load: Construction Type: -Flood Zone: - BFE: FFE:
OWNER: Name (Fee Simple Titleholder): James Alveh Bay Jr. Phone#: 305-215-8007
Address: 1019 NE 104 St.
Miami Shores
City: .-------Zip: 33138
Tenant/Lessee Name: NA -Phone#: NA
Email: NA
CONTRACTOR: Company Name: C & G Professional Contractors, Inc Phone#: 305-527-0581
Address: 9254 NW 120 Ter
City: Hialeah Gardens State: FL Zip: 33018
Qualifier Name: Juan Carlos Data Phone#: 305-527-0581
State Certification or Registration* _CCC 1328983, -Certificate of Competency#: NA
DESIGNER: Architect/Engineer: NA - Phone#: NA
Address: NA City: NA State: NA Zip: NA
Value of Work for this Permit: $ 30,000. 00 Square/Linear Footage of Work: 3200
Type of Work: [3 Addition [I Alteration New Repair/Replace El Demolition
Description of Work: Tile Re -roof
Specify color of color thru tile: L? air V\ C-LX_a�oqj -3 ( � V-- CA -
Submittal Fee $ Permit Fee $ CCF $ CO/CC
Scanning Fee $ Radon Fee $ DBPR $ Notary
Technology Fee Training/Education Fee$ Double Fee$
Structural Reviews Bond $ - -0I)
TOTAL FEE NOW DUE $,
(Fo!vis�dW/24/2014)
Bonding Company's Name (if applicable) NA
Bonding Company's Address NA
City NA State NA� zip NA
Mortgage Lender's Name (if applicable) NA
Mortgage Lender's Address NA
City NA State NA Zip NA
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning,
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT.,,
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in goad faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice; the
inspection will not be approved and a reinspection fee will be charmed,
Signature
,,.--OWNER or AGENT
The foregoing instrument was acknowledged before me this
day of tva_✓C1-., 120 , by
James Bay who is personally known to
me or who has produced f-L— i�, 2--- as
identification and who did take an oath.
NOTARY PUBLIC:
1
Signature
CONTRACTOR
The foregoing instrument was acknowledged before me this
day of / �C'� by
Jinn Carlos Cata who is personally known to
me or who has produced f— L as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:_,,'✓ v � �.. 5ign:
Print; v , C', '^ (�%� Print: ,� ��a/✓`
Seal: Seal: r" Notary Public State of Florida
£r*'ft Notary Public State of Florida *; Cristhian Grillo
_ Cristhian Grillo My Commission GG 327914
O) + . My CoSmmissiozn ?GG 3279t4��� Expires 05/31/2023
a%>xd+�b�FB tk�tyK� �� way rtl�ic►Wa*�j�@+�y+��Ms+ah**!M& ' *#+G** ***iA****Atl+**;0*****
APPROVED BY
Plans Examiner
(Revised02/24/20]4)
Structural Review
.�� Clerk
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
CONTRACTORS' REGISTRATION
IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR:
A. N/ COPY OF QUALIFIER'S STATE LICENCES
B. ✓ COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF LIABILITY INSURANCE*
D. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit)
IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY:
A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER
B. COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL
CONTRACTOR'S TAX RECEIPT.
D. COPY OF LIABILITY INSURACE*
E. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit)
*YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW:
Certificate Holder:
MIAMI SHORES VILLAGE BLDG DEPT
10050 NE 2ND AVE
MIAMI SHORES, FL 33138
Certificate must specify the description of operations or contractor license number.
■■rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr■
BUSINESS NAME: C & G Professional Contractors, Inc
BUSINESS ADDRESS: 9254 NW 120 Ter
CITY Hialeah STATE FL ZIP 33018
BUSINESS PHONE: 3( 05 ) 527-0581 FAX NUMBER ( )
CELL PHONE ( )
QUALIFIER'S NAME: Juan Carlos Cata
QUALIFIER'S LIC NUMBER: CCC 1328983
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
I
E
Florida Building Code 5th Edition (2014)
1
High -Velocity Hurricane Zone Uniform Permit Application Form. 1
1
1
Section A (General Information) 1
Master Permit No. Process No. 1
C & G Professional Contractors, Inc 1
Contractor's Name 1
Job Address
1019 NE 104 St. Miami Shores, FL 1
1
ROOF CATEGORY 1
1
❑ Low Slope O Mechanically Fastened Tile Mortar/Adhesive Set Tiles 1
❑ Asphaltic Shingles O Metal Panel/Shingles O Wood Shingles/Shakes 1
O Prescriptive BUR-RAS 150 1
ROOF TYPE 1
❑ New roof ❑ Repair O Maintenance Reroofing O Recovering 1
ROOF SYSTEM INFORMATION 1
Low Slope Roof Area (SF) Nip` Steep Sloped Roof AREA (SSF) Total (SF) 1
1
1
Section B (Roof Plan) 1
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1
1
1
IN
C7
01
0
Ln
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37
t I t ' I ( Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezcr Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
C a 0 PROFESSIONAL
CONTRACTORSINC.
C & G Professional Contractors, Inc.
9254 NW 120 Terrace, Hialeah Gardens, FL 33018
Phone # 305-527-0581 or 786-295-8836
www. cbproroof.com
CCC # 1328983
1019 NE 104 St. Miami Shores. FL
Roof Sketch
Page 1 or I
-7 V
m
Scanned with CarnScanner
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
1
1
1
1
1
I
1
1
1
1
1
1
I
I
1
1
1
1
1
1
1
1
1
I
1
1
i
1
1
1
1
1
1
1
1
1
1
Flo ri
, ilding Code '' dition (2014)
High -Velocity l-I Me
one Un .: Permit Application Form.
Section C (Low Slope Application)
op Ply Fastener/Bonding Material:
Fill in specific roof assembly components and ide
1
manufacturer
Su ng:
1
(If a component is not used, identify as "NA")
Fastener Spacing for Anchor/Base Sheet Attachment:
1
System Manufacturer:
Field: " oc @Lap, # Rows @ ' oc
1
1
Product Approval No.:
Perimeter: " oc @ Lap, # Rows _ @ " oc
1
1
Design Wind Pressures, From RAS 128 or Calculations:
Corner: " oc @ Lap, # Rows @ " oc
1
Number of Fasteners Per Insulation Board:
P 1: P2: P3:
1
Field Perimeter Corner
1
Max. Design Pressure, from the specific product
_
i
approval system:
Illustrate Components Noted and Details as Applicable:
Deck:
Woodblocking, Gutter, Edge Termination, Stripping, Flashing,
1
Continu Cleat, Cant Strip, Base Flashing, Counterflashing,
1
Type:
Copi
1
In ' -: Mean Roof Height, Parapet Height, Height of Base
1
Gauge/Thickness:
ing, Component Material, Material Thickness, Fastener
pe, Fastener Spacing or Submit Manufacturers Details that
1
Slope:
mply with RAS 111 and Chapter 16.
1
Anchor/Base Sheet & No. of Ply(s):
1
1
Anchor/Base Sheet Fastener/Bonding Material:
1
1
FT_ .
Insulation Base Layer:
1
Base Insulation Size and Thickness:
Parapet
Height
1
1
Base Insulation Fastener/Bonding Material:
1
1
Top Insulation Layer:
1
1
Top Insulation Size and Thickness:
Mean
1
Roof
1
Top Insulation Fastener/Bonding Material:
Height
1
1
Base Sheet(s) & No. of Ply(s): 1
Base Sheet Fastener/Bonding Material: 1
1
i
Ply Sheet(s) & No. of Ply(s):
1
Ply Sheet Fastener/Bonding Material:
1
1
Top Ply: 1
1
15,38 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) '
i 1 ' t I 1 ' 11102
am Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Elie= Palacio on Jun B, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer: BOral Roofing, LLC
1
1
1
I
l
1
Notice of Acceptance Number: 18-0509. 7 1
1
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 1
P1: -39.1 P1: -68.1 Pi: -100.7
1
Two Patty Install Per NOA 1
1
Deck Type: 5/8" Wood Deck 1
1
Roof Slope:Type Underlayment: 1 #30 Saturated Base Sheet ( 1
1
3 12 1
Insulation: NA 1
1
Fire Barrier: NA 1
1
f Ridge Ventlation? Fastener Type & Spacing: 1 1/4"RS nails on 1 5/8" TC @
NA 1
l Adhesive Type: NA 1
1
I Mean Roof Height: 12
i
1
Type Cap Sheet: Polyglass TU Plus 1
Roof Covering: 13" Flat Tile Saxony Slate 900
1
Type &Size Drip 3 x 3 Glav 26 Gau e
Edge:
1
1
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39
1 ' 1 l I l Copyright to, or licensed by, ICC (ALI. RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
III Agreement. No further reproductions authorized.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
i
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
t
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from M,. If the M, values
are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127"
(P1: -39.1 x X .315 =-12.32) - Mg: 7.62 = M,, 4.70 Product Approval M, -31.3
(P2: -68.1 xX .315 =-21.45) _ Mg: 7.62 = M2 13.83 Product Approval M, -31.3
(P3:-100.7xX .315 = _31.72) - Mg: 7.62 = M, 24.10 Product Approval M, -31.3
* Method 2 "Simplified Tile Calculations Per Table Below" 2 Patty install per NOA
Required Moment of Resistance (M,) From Table Below Product Approval M,
M, required Moment Resistance'
Mean Roof Height
Roof Slope
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
"Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and
Appeals.
For Uplift based the systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 127"
(P1: x L - x w: = ) - W: x cos 0 _ = F„ Product Approval F'
(P2: x L = x w: = ) - W: x cos 0 = F2 Product Approval F'
(P3: x L = x w: = ) - W: x cos 0 = Fr, _ Product Approval F'
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis pre-
pared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
1
Product Approval
Restoring Moment due to Gravity
M9
Product Approval
Attachment Resistance
M,
Product Approval
Required Moment Resistance
Mg
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
lProduct Approval
All calculations must be submitted to the building official at the time of permit
application.
15.40 FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014)
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8. 20110:32:12 AM pursuant to License
Agrcernent. No further reproductions authorized.
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit; and to explain to the owner the content of the section. The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system installations. ,Additionally, the
following items should be addressed as part of the agreement between the owner ant the contractor. The owner's
initial in the designated space indicates that the item has been explained,
2. Renailing wood decks: When replacing roofing: the existing wood roof deck may have to
b renailed in accordance with the current provisions of Section R4403. (The roof deck is usually
concealed prior to removing the existing roof system).
4. �.viewbeamExposed Ceiling: Exposed, open ceilings are where the underside of the roof decking
coed from below. The owner appearance; may wish to maintain the architectural a therefore
pp � >
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance
Xv"__ _ Overflow scuppers (wall outlets): it is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. it may be necessary to install overflow
scuppers in accordance with the requirements of Sections R4402, R4403 and R4413.
3 � r, a
Cw /Agents Signature „gate ntractor ignature Cate
1019 NE 104 St. Miami Shores, FL
Property Address Permit dumber
Revised on 7/9/2009 LD;0741/2015;
%
Miami shores illa e
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel; (305) 795.2204
Fax: (305) 756.8972
OWNER'S'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE.
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F,S,
To: Miami Shores Village Building Depart nenf, Gate: 02-25-2020
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name; roes A Bey
Property Address:_ 1 19 NE 104 51__Miamies. F.1.
Roofing Permit Number;
[Dear Building Official:
I James A Bay ._ certify that ! am not required to retrofit the roof to wall connections of my'
building because:
XThe just valuation for the structure for purpose: or ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of the South Florida Building Lod.; (19914 SF -BC)
James A Bav
Signature Print Name
State of Florida
County of Dade
The undersigned, being the first duly sworn: deposes and says that he/she is the owner for the above property mentioned,
Sworn to and subscribed before me this day of
Notary Public Stale of Florida
Cristhien Grillo
Notary Public, Sate of Florida at large �, _
R
r w
Express 05/31202a
f her the ;ust valuation cf the strucure for purGoye 6f as{ rem taxation {s aqua io yr re n . . ntl the 001ding was not constnr led with FBC nor ra 1H4
SFBC Then you must provide a building application frcm a Generai Contactor for the R t to wall connecticn Hurricane Mitig;,tiar..
MIAMI-Q E
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economv
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.
MIAMI•DADE COUNTY NOA No.: 17-0614.22
... � M Expiration Date: 09/13/21
Approval Date: 07/06/17
Pagel of 8
ROOFING COMPONENT APPROVAL
Categorv: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product
Dimensions
Specification Description
Polystick IR-Xe
65' x 3'33/8"
ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Manufacturing
Or 65' x 3'
polymer modified, fiberglass reinforced, bituminous
Location # 1 & #2
60 mils thick
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
61' x 3'33/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location 42
metal roofing and roof tile underlayment.
Polystick Tile Pro
61' x 3'33/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Location #2
roofing and roof tile underlayment.
Polystick TU Max
65'8" x 3'3-3/8"
TAS 103 and A rubberized asphalt self -adhering, polyester reinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location # 1 & 42
underlayment.
Polystick TU P
32'10" x 3'3 3/s"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 3'3 3/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location # 1 & #2
Polystick MTS
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus
65'8" x 3133/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3 3/s"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1, Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency.
Test Identifier
Test Name/Report
Date
Trinity ERD
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08.12-2
ASTM D 1623
08/07/12
P37590.07.13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D 1623
05/12/14
P46520.10.14
ASTM D1623
10/03/14
P44360.10.14
TAS 103 & TAS 110
10/07/14
P43290.10.14
ASTM D 1970 & TAS 110
10/17/14
PLYG-SC10130.06.16-3
TAS 103 & TAS 110
06/27/16
PLYG-10130.06.16-1
ASTM D1970 & TAS 110
06/27/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
09/29/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX201-17A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
MiaMi•ouaDE couNrY NOA No.: 17-0614.22
... � Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton,PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS Plus
MTS Plus with
Dual Pro
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
m
a
0
cc
N
m
POL`SnCKTU Rue
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of T712" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
�� NOA No.: 17-0614.22
MIAMMAD, COUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
MIAMI-DADE COUNTY
MIAMI PRODUCT CONTROL SECTION
+1 '
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
ICP Adhesives and Sealants, Inc.
12505 NW 441' Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
FOO&M-0m(w
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A
Polyset®AH-160
ICP Adhesives Foam N/A
Dispenser RTF1000
ICP Adhesives ProPacko N/A
30 & 100
TAS 101 Two component polyurethane foam adhesive
PRODUCTS MANUFACTURED BY OTHERS:
Dispensing Equipment
Dispensing Equipment
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Fe
Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch
Dimensional Stability ASTM D 2126 +0.07% Volume Change @ 40' F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MIAMI•DAD; COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
Test Name/Reuort
Date
#94-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/16/96
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
NB-589-631
ASTM D 1623
02/01/94
9637-92
ASTM E 108
04/30/93
01-6743-011
ASTM E 108
11/16/94
01-6739-062b[1]
ASTM E 84
01/16/95
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset' AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset' AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0 (B).
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP
Adhesives ProPack® 30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
MIAMI-DARE COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
)U2 through plastic crwtont Paddy lgwnaath Taal
tindprisympnt . Jl`0�-1�! .'
(fattens optional
raye, Course
` .-.
Ale
Nall through plastic cement
(when required)
Paddy413enepthTOO
tlnderlaynwrrt 1 `y
,:.. `.,may •�
S 21t�wIdF a. -4-
7
tattensoptlonal I
-.
Ease Closure
Ear* Coarse i ' �a J ✓' _Fascia
NSA tHaugfi plastic carpvnt-.-
(when requittdi f Paddy l9pneathTilri
Underl,syrnent
f [) gin. x '• � -�" 7..
2 in. wide . I
Warns J •.,,� --' f
optional
EaveCoutso - ' ``► + k = Fatda
weep -hole
10in in. rf K� !' + Eaeeclosure
ti. "I Drip adrta
Flat/Low Profile Tile
1. Starting at the cave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm') — 23 (148.4 cm') square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the cave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cml) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the cave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
tQail through Slit rrmrnt Nddy IEYnYathI&I
Qwhen regwred?
V1ndeAayrnent ,:y � � ��"• �
i
Battens optional ,-
Eaw Course t!-rf
✓ a �`.�� ,T�4 ~~'�. � p "'!=:!''' ,r•
�. 10irs`
2 in,;,,
,ter
Alai►through p4wit cement
twhen requiredl
Paddy tgenea4h Tllap
Undrrlaynrnt
01
Qatt+•nsoptionai ''•-�'.� �t.,�''Y.1`
Cove C sum
ENVYCnyr\r
MIAMI-DADE COUNTY
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm') - 12 (77.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm') —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
Nail0wough plastic ceprerrt,`
(when tequlted ) V, . (P+WdY larn.ath Tilvj
Vrld"Ymrnt
Tin - 2In.
eattensOptimalVV
%ter r' l•
T cave (our"
FaKip
.4 � t ` f y iYwrpholr
�r 10Rn.2�Eave closure
Drip *d9t
1n .,r
High Profile / Single Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm') square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
Continue in same manner. Insure approximately 17"
(109.7 cm') - 19 (122.6 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
naiithroughpiasticcement
(when
Paddy (between tiles)
required!
I
Battens optional
°
p�
t Paddy (undertile)
M Singiepaddy
on tap of the
1
�•
4 x 4 In.
't
rctdertil
Single paddy
- - •,.
on u.dedayment 2 x a in.
f
•``�,~
�
tole.
• in.
Fascia
Eave Closure
Flat/Low Profile Tile
Nall through plastic cement Single paddy under tile
(when required)
Paddy ibetween tiles)
Battens ( paddy(under tile)
optional - r
Single paddy
on top of tde�
4x 4 in. /
2 x
Sinnggle paddy on
w�derlayment!
loin. 2in.
Eave Closure
Eave Course Fascia
Medium ProflleTile
Ir-
APPROVED J
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the the for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in (109.7-148.4 cm') of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x V (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the underlock for
the second course tile to be installed. Insure
approximately 8-9 In (51.6-58.1 cm') of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Nail through plastic ce
Single paddy under tie
{when required)
Paddy ibetween tiles)
Battens
optional �•
_
Paddy (under tile)
Single j+?d
on unaena
r
4x41n.
She z u s in.pa o
top of file -=
Eave Course
Fascia
weephole
Loin. tin.
Eave dosare
Drip edge
High ProflleTile
MIAMI•DADE COUNTY
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) - 9 (58.1 cm2) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications
In contact with the pan tile. (when required)
2) Turn covers upside down. Place adhesive in
to 1 in. from outside edge of cover tile.
Then install the tile. Ensure 20 to
25 sq. in. contact area.
Underlayment ''' -
Sheathing
Eave closure
(motar shown)
Weephole
Fascia Board
Remove top portion of the save course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimurn 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm') — 70 (451.6 cmz)
square inch adhesive contact with the underside
of the pan tile.
3. Turn covers upside down exposing the underside
of the tile. Apply a minimum 1" (25.4 mm) x 10"
(254 mm) bead of adhesive directly on the inner
edge of each side of the cover tile. Leave
approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm') - 25 (161.3 cm') square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
MIAMF E
� MIAMI-DARE COUNTY
L��L'�11Y PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Saxony 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.16-0711.05 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino U
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 1 of 9
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub-Catei!orv:
Roofing Tiles
Material:
Concrete
Deck Tyne:
Wood
1. SCOPE
This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as
manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations
where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure
values obtained by calculations in compliance with RAS 127 using the values listed in the installation section
herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Product
Annlicant
Dimensions
Saecifications
Descrintion
Saxony 900-Slate
Length = 17"
TAS 112
Flat profile, interlocking, high-pressure extruded
Width = 13"
concrete roof tile with two nail holes. For direct deck,
thickness = 1-5/32"
batten, mortar set or adhesive set applications.
Saxony 900
Length = 17"
TAS 112
Flat profile, interlocking, high-pressure extruded
Split Shake
Width = 13"
concrete roof tile with two nail holes. For direct deck,
thickness = 1-9/32"
batten, mortar set or adhesive set applications. Top
surface produced with 4 different configurations:
1. Complete tile brushed
2. Right half brushed (shown in drawing)
3. Left half brushed
4. No brush
Saxony 900-Shake
Length = 17"
TAS 112
Flat profile, interlocking, high-pressure extruded
Width = 13"
concrete roof tile with two nail holes. For direct deck,
thickness = 1-9/32"
batten, mortar set or adhesive set applications.
Trim Pieces
Length: varies
TAS-112
Accessory trim, boosted Barcelona, concrete roof
Width: varies
pieces for use at hips, ridges and rakes.
varying thickness
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 2 of 9
2.1 MANUFACTURING LOCATION
2.1.1 Lake Wales, FL
2.2 EVIDENCE SUBMITTED:
Test A2encv
Test Identifier
Test Name/Reaort
Date
The Center for Applied
94-084
Static Uplift Testing
May 1994
Engineering, Inc.
TAS 101 (Mortar Set)
The Center for Applied
94-060A
Static Uplift Testing
March, 1994
Engineering, Inc.
TAS 101 (Adhesive Set)
The Center for Applied
25-7183-6
Static Uplift Testing TAS 102
Feb. 1995
Engineering, Inc.
(2 Quik-Drive Screws, Direct Deck)
The Center for Applied
25-7183-5
Static Uplift Testing TAS 102
Feb. 1995
Engineering, Inc.
(2 Quik-Drive Screws, Battens)
The Center for Applied
25-7214-1
Static Uplift Testing TAS 102
March, 1995
Engineering, Inc.
(1 Quik-Drive Screw, Direct Deck)
The Center for Applied
25-7214-5
Static Uplift Testing TAS 102
March, 1995
Engineering, Inc.
(1 Quik-Drive Screw, Battens)
The Center for Applied
Project No. 307025
Wind Driven Rain
Oct. 1994
Engineering, Inc.
Test #MDC-77
TAS 100
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix II & III
TAS 108 (Nail -On)
Redland Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
TAS 108 (Nail -On)
Redland Technologies
P0631-01
Wind Tunnel Testing
July 1994
TAS 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
Atlanta Testing &
R1.894/R2.894/R3.894
Physical Properties
Aug. 1994
Engineering, Inc.
TAS 112
Celotex Corporation
520109-1
Static Uplift Testing
Dec. 1998
Testing Service
5201114
TAS 101
Celotex Corporation
520191-1
Static Uplift Testing
March 1999
Testing Service
TAS 101
Walker Engineering, Inc.
Evaluation Calculations
25-7094
February 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7496
April 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7584/25-7804b-8/25-7804-4 & 5
December 1996
25-7848-6
Walker Engineering, Inc.
Evaluation Calculations
25-7183
March 1995
Walker Engineering, Inc.
Evaluation Calculations
Aerodynamic Multipliers
09/01/16
Walker Engineering, Inc.
Calculations
Two Patty Adhesive Set System
April 1999
Walker Engineering, Inc.
Evaluation Calculations
Restoring Moments Due to Gravity
09/01/16
American Test Lab of
RT0617.04-16
TAS 112
06/29/16
South Florida
NOA No.: 18-0509.17
MIAMI•DADE COUNTYM Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 3 of 9
PRI Construction Material COPO-002-02-12 TAS 101 10/12/2016
COPO-002-02-06 TAS 101 10/12/2016
COPO-002-02-05 TAS 101 10/12/2016
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
the applicable Building Code.
4. INSTALLATION
4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
Length -I (ft)
Width-w (ft)
Saxony 900
Slate Shake & Split Shake
10.9
1.417
1.08
Table 2: Aerodynamic Multipliers (ft3)
Tile
% (ft3)
�, (ft3)
Profile
Batten Application
Direct Deck Application
Saxony 900
0.291
0.315
Slate Shake & Split Shake
Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf)
Tile
Profile
211:12"
3":12"
4"•12"
5":12"
610:12"
7":12" or
greater
Saxony 900
Slate, Shake &
Split Shake
Direct Deck
Direct Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
7.70
7.62
6.61
7.50
1 6.48
7.34
6.31
7.16
1 6.13
6.95
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 4 of 9
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Mechanically Fastened Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32"
plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
Saxony 900
Slate, Shake & Split
Shake
2-10d Ring Shank Nails
30.9
38.1
17.2
1-10d Smooth or Screw Shank Nail
7.3
9.8
4.9
2-10d Smooth or Screw Shank Nails
14.0
18.8
7.4
1 48 Screw
30.8
30.8
18.2
2 .#8 Screws
51.7
51.7
24.4
1-10d Smooth or Screw Shank Nail (Field
clip)
24.3
24.3
24.2
1-10d Smooth or Screw Shank Nail (Eave
clip)
19.0
19.0
22.1
2-10d Smooth or Screw Shank Nails (Field
Clip)
35.5
35.5
34.8
2-10d Smooth or Screw Shank Nails (Eave
clip)
31.9
31.9
32.2
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf)
for Two Paddy Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Saxony 900 Slate, Shake & Split Shake
Adhesive'
31.3 2 & 3
594
1 See foam adhesive manufacturer's component approval for installation requirements.
2 The Dow Chemical Company TileBondT one -component foam minimum weight per paddy 13.9 grams.
3. ICP Adhesives PolysetO AH-160 two -component foam, minimum weight per paddy 8 grams.
4. DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Paddy Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Saxony 900 Slate, Shake & Split Shake ICP Adhesives Polyset@ AH-160
Two -component foam
DAP Products Touch N' Seal Storm
Bond 2 two -component foam
118.9 3
40.4 4
93 5
456
3 Large paddy placement of 45 grams of Polyset® AH-160.
4 Medium paddy placement of 24 grams of Polyset® AH-160.
5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per
paddy 45 grams.
6 Medium paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 24 grams.
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 5 of 9
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Minimum Attachment
Resistance
Saxony 900 Slate, Shake & Split Shake
Mortar Seth
43.96
7 Tile-Tite Roof Tile Mortar
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed
below, or following statement: "Miami -Dade County Product Control Approved".
LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
PROFILE DRAWINGS
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 6 of 9
NAIL HOLES
19
UNDERLOCK
SAXONY 900 - SLATE
APPROVED
5/32" (Slate)
COVERLOCK
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 7 of 9
NAIL HOLES
PROFILE DRAWINGS
0
Note: Available Top Surface Finishes
5. Complete tile brushed
6. Right half brushed (shown in drawing)
7. Left half brushed
8. No brush
SAXONY 900 - SPLIT SHAKE
APPROVED
1-9/32" (Shake)
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 8 of 9
NAIL HOLES
Q
PROFILE DRAWINGS
SAXONY 900- SHAKE
END OF THIS ACCEPTANCE
1-9/32" (Shake)
NOA No.: 18-0509.17
Expiration Date: 04/26/22
Approval Date: 08/02/18
Page 9 of 9