Loading...
MC-20-312Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit NO.: MC-02-20-312 D o f-'Li Permit Type: Mechanical -Residential U� work Classification: A/C Replacement Jnj Permit Status: Approved Issue Date: 05/05/2020 I Expiration: 11/02/2020 Location Address Parcel Number 1010 NE 105TH ST, Miami Shores, FL 33138 1122320280020 Contacts Joyce Bonham Owner 1010 NE 105 ST ACV-2 AIR CONDITIONING CORP Contractor JORGE LUIS ACEVEDO 901 NW 132 PL, MIAMI, FL 33182 Business: 3055461143 billing.acv2air@gmail.com Description: REPLACE A/C 4 TON Valuation: $ 8,346.44 Inspection Requests: Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $5.40 DBPR Fee $4.38 DCA Fee $2.92 Education Surcharge $1.80 Permit Fee $242.13 Scanning Fee $9.00 Technology Fee $7.30 Total: $322.93 Payments Date Paid Amt Paid Total Fees $322.93 Credit Card 04/01/2020 $322.93 Amount Due: $0.00 COVID 19 Applicant Copy For Inspections, Call (305) 762-4949 or Log on at https://bidg.miamishoresvillage.com/cap/. Requests must be received by 3pm for following day inspections. NOTICE: In addition to the requirements of this permit, there may be AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER additional restrictions applicable to this property that may be found in the GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, public records of this county. STATE AGENCIES, OR FEDERAL AGENCIES. May 05, 2020 Page 1 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tole (305) 795.2204 F 305 756 89 2 ENTERED FEB 10 2 20 BY: ax.( ) - 7 INSPECTION LINE PHONE NUMBER: (305) 762-0949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑PLUMBING FEI MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: 1010 NE 105 ST 1�FBC 20NI ' Master Permit No. � 1 n! C— 0 2 "W" 3 I "L Sub Permit No. ❑ REVISION ` ❑ EXTENSION ❑RENEWAL [:]CHANGE OF - ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:11-2232-028-0020 Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone OWNER: Name (Fee Simple Titleholder):JOYCE BOHAM Address:1010 NE 105 ST City. MIAMI SHORES State: FL BFE: FFE: Phone4:305-895-6054 Tenant/Lessee Name: Phone#: Email: WATBON99@GMAIL.COM p: 33138 CONTRACTOR: Company Name: ACV-2 AIR CONDITIONING Phone#: 786-290-2023 Address: 901 NW 132 PL City. MIAMI State: FL Zip: 33138 Qualifier Name: JORGE ACEVEDO Phone#: 786-290-2023 State Certification or Registration #: CAC 1815085 Certificate of Competency #: DESIGNER: Architect/Engineer: Value of Work for this Pe it: $8,346.44 Type of Work: ❑ A ition ❑ Alter Phone#: City: State: Zip: Square/Linear Footage of Work: ❑ New 0 Repair/Replace Description of Work: K AC �j -" `per ❑ Demolition Specify color of color thru tile: Submittal Fee $� Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Technology Fee $, Structural Reviews $ Radon Fee S Training/Education Fee $ DBPR $ Notary $ Double Fee $ Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zip City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS,14EATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. iF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $25W, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issue¢!%In the absen such posted notice, the inspection will not be approved and a reinspection fee will be charged. � -1 Signature 4R--�---- OWNER or AGENT The foregoing instrument was acknowledged before me this Q7 day of FEBRUARY 2020 by JOYCE BOHAM who is personally known to me or who has produced DRIVER LICENSE as identification and who did take an oath. NOTARY PUBLIC: The foregoing instrument was acknowledged before me this 07 day of FEBRUARY 2020 by JORGE ACEVEDO who is personally known to me or who has produced KNOWN as identification and who did take an oath. NOTARY PUBLIC: Sign: Sign: Print.IR WNW Print: fRE111 Seal: ` MY COMMISSION # GG 2"434 Seal: ' ;.# MY COMMISSION g GG 2TT434 :• EXPIRES: Demmber<, 2022 aA'� EXPIRES: December4, 2022 Bonded ThN NOfetY POWo Fee i ;°, Bnnftd Thm Notary Pub0c LV4w*Aln 40#ii##sisi#i##s#ii##•f#####iii##tii################i##### APPROVED BY Plans Examiner Zoning Structural Review Clerk (RevrA402/24/2014) 2/6/2020 ACV2 Air Proposal "cv-2=%%- -- ACV2 Air Your ACV2 Air Proposal Joyce Boham Address: 1010 Northeast 105th Street Miami Shores, Ft. 33138 Consultation Code: FNGYD75V1 Phone: (305) 895-6054 Ernail: Watbon99@gma;l.com About Us Welcome to ACV2 Air, Date Presented: Feb 6, 2020 Date Accepted: Feb 6, 2020 Presented by: Dash;e'l Her Phone: (786) 290-2023 Email: ACV2AIR@GMAIF.00M CALL US TODAY (786) 907-4995 For years we have been a premier provider of high quality air conditioning and ventilation services. What makes ACV2 Air different from other HVAC service providers in the region? We pride ourselves on offering expert services to each one of our customers from ensuring your new cooling system is properly installed to keeping it running efficiently on an annual basis for years to come. Each of our highly qualified technicians have the ability to provide the utmost in service to each of the customers they visit and they are prepared for nearly any issue that could arise. ee CAC1815085 ter.: G-Z— p MOF 1$ 9 H.;, tP ra SWo A rrp,ir ZAIrtn-suI a ELECTRIC Ckongea to, Ike. 9'rue.- https://app.oncallair.com/#/proposal/accepted/l 45456/402067?showBack=true 1/5 2/7/2020 ACV2 Air Proposal Notes No notes were entered. Equipment System Carrier Performance 24ACB7 AC 4 Ton AHRI Matched SEER:161 EER: 131 CC:48000 System Subtotal: $13,546.44 See total investment below Category: Condenser Name: Carrier® PerformanceTM - 4 Ton 17 SEER Residential 2-Stage Air Conditioner Condensing Unit Number: Category: Fan Coal Name: 2.5 - 4 Ton Residential Fan Coil Variable Speed Multipoise (Aluminum Coil) Number: Includes 2 items 2 items https.//app.onca!lair. com/#/proposallacceptedl145456/402067?showBack=true 2/5 2/612020 ACV2 Air Proposal Category: Thermostats (Qty: 1) Name: Ecobee SmartThermostat with Voice Contro Number: Category: HVAC Add-Ons (Qty: 1) Name: KFCEH0501NO5 - Fan Coil Electric Heater Kit 5 kW @ 240V Number: What you'll get Check, test and start-up per factory specifications 17 iterns Standard Install Kit w1 Digital Thermostat Includes: reclaim refrigerant, disable electrical, remove system, inspect duct work, clear existing drain line, flush refrigerant lines, connect new indoor unit to existing high and low voltage electrical, drain line and copper lines, seal new indoor unit to existing duct work, install new thermostat, install AC accessories per contract, vacuum existing refrigerant lines, balance new system refrigerant via sub -cooling, secure outdoor unit to concrete pad, install new filter drier, confirm proper cooling and heating function and remove all installation material and debris. 10 years Compressor, Coil and Parts Warranty Labor Warranty 2 years ACV2 Air Proactive 1 year one visit service maintenance plan Remove and Haul away old unit with environmentally responsible recycling https://app.oncallair.com/#/proposal/accepted/145456/402067?showBack=true 315 2/7/2020 ACV2 Air Proposal Permit Application and Handling Duct run - replace existing flex Investment Details Sale Price MCOUNT Acv2 Air Disc REBATE Dash Disc Total Investment The Total Investment is the total cost of the goods and services described in this proposal Payment Terms Quantity: 10 $13,546.44 - $ 2, 700.00 - $2,500.00 $8,346.44 You agree that payments will be due as indicated below. If You are paying by credit, debit, or check, the account may be charged or debited (as applicable) on the same day that it is accepted by the ACV-2 Representative or Installation Professional. Credit or debit card may have a processing fee not included on the contract. https:/rapp.oncallair.com/#/proposal/accepted/145456/402067?showBack=true AM 2/6/2020 Signature ACV2 Air Proposal Terms and Conditions P dO r. id.&k - 0— M�� All material is guaranteed to be as specified. All work is to be completed in a professional manner according to standard industry practices. Any alterations or deviations from the described work involving extra costs will be executed with written orders and w. I be an extra charge over and above the original estimate. All agreements contingent upon strikes, accidents. force majeure, or delays beyond our control Owner/Owners are to carry all necessary insurance. The company workers are covered by Worker's Compensation insurance.) he above prices, specifications, and conditions are satisfactory and are hereby accepted and the company is is authorized to preform the work specified. Payment will be made as outline above. Any payment not made as specified shall be sutrect to 18%annual interest plus biil,ng charges. court costs and attorney fees. Prices are subject to change if not accepted within 15 days. By signing below, you authorize ACV-2 Air Contractor to arrange for installation Professional to perform installation and/or order and arrange for the delivery of special order s merchandise, including special order merchandise that may be custom made, as specified in this agreement. You understand this agreement constitutes the entire understanding between You and ACV-2 Air Contractor. By sign'ng, you acknowledge that You have read, understand, and accept this Agreement in its entirety. PAYBLE TO: ACV-2 AIR CONTRACTOR https://app.oncallair.corIV#/proposal/accepted/145456/402067?showBack=true 5/5 Miami Shpj-rs Village .B�,ilding•D�partmehl`••• ::•1a050 flt.2h Avenue'. P4ia1OL51-cores, Florida 33 S46** •... Tel: f 30%79S.2Z04••; •••••• Fax 16;1j 56.8932•• . . .... ...• ... 00 .... ...... PERMIT NUMBER; MC .. •• This form must accompany ALL air conditioning replacement permit applications. Eacli unit chamie'out must • be on its own data sheet. Multiple units on single sheets are not acceptable, Job Address (where the work is being done): 1 (0 1 q0 V-) i° I Q J City: Miami Shores Village County: Miami Dade Zip Code: i39�l s ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES ❑ NQ ARHI Sheet Attached: YES Q NO ❑ Contract Attached: YES Q UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER CARRIER AHU or PKG. UNIT MODEL # ' COND. UNIT MODEL # KW HEAT NOM TONS AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT PKG UNIT j f EER/SEER YES NO REPLACING DUCTS YES NO YES NO REPLACING THERMOSTAT YES NO YES NO NEW 4"CONCRETE SLAB YES NO YES NO NEW ROOF STAND YES NO YES NO NEW RETURN PLENUM BOX YES NO I. Minimum Circuit Ampacity (Wire Size): rG 2. Maximum Overcurrent Protection (Fuse/Breake Size): Z-4 0 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: __ (q-1 Contractor's Company Name: 1 ` Z% t i' Phone: "� e%C`73 State Certificate or Registration No. C4-C_ d S . &S� IECertificate of Competency No. Signature (Qua:ifiees signature) Date: (Revised02/24/2014) certificate of Product .. • ..•••. Ratingse:...: • ;••:. :• AHRI Certified Reference Number: 10360206 Date: 02-10-2020 Model Status: Active �: • • • • • • • ; ' • AHRI Type: RCU-A-CB • . • Series: PERFORMANCE 17 AC 2-STAGE • • • . • • • • Outdoor Unit Brand Name: CARRIER • • . • • • • Outdoor Unit Model Number (Condenser or Single Package) : 24ACB748A*031** Indoor Unit Model Number (Evaporator and/or Air Handler) : FV4CN(B,F)005L Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this CARRIER product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump" Equipment and subject to rating accuracy byAHRI-sponsored, independent, third party testing: Cooling Capacity (A2)- Single or High Stage (95F), btuh : 48000 SEER 16.00 EER (A2) - Single or High Stage (95F) 13.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rating is shown alonq with the previous (i.e. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life• bettei- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ---"""" "' " ©2020Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132258424670231168 Miami Shores Village BuildingOLspartment e U050 N E.2t,d Avehee Mia ii*Shore;,* Flcrii a 331�, �• Tel: (3q,5) 795.2, 04 • • • • • Fa*,( _� 756.8M* *: .... . ..... •.•..• • PERMIT NU • •� lbB�R: MC • This form must accompany ALL air conditioning replacement permit applications. Each •• •+•s•• be on its own data sheet. Multiple units on single sheets are not acceptable, 't chahge'dut mud • Job Address (where the work is being done): 1 (01 40 n 6 10 Is S-f City. Miami Shores Village County: Miami Dade Zip Code: _ I ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED 'tj Change disconnecting means: YES ❑ NQ ARHI Sheet Attached: YES ❑/ NO ❑ Contract Attached: YES 7 UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER AHU or PKG. UNIT MODEL # CARRIER COND. UNIT MODEL # ELM d LI KW HEAT © �� NO M TONS AHU CU PKG 1) M.C.A AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / AHU CU PKG PKG UNIT / / EER/SEER YES NO REPLACING DUCTS YES ) YES NO REPLACING THERMOSTAT NO YES NO NEW 4' CONCRETE SLAB YES NO YES NO NEW ROOF STAND YES NO YES NO NEW RETURN PLENUM BOX YES NO YES NO I. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breaker Size): — .If4 o 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: Contractor's Company Name: 5t!OR u■■ mn M IDA L�r AIR CONDITIONING REPLACEMENT DATA Phone: ��L�CU�3 State Certificate or Registration No. ��G j��i ��Certificate of Competency No. Signature (Qualifier's signature) Date: T Al in (Revised02/24/2014) f Certificate of Product Ratingj:*:::'*0 .•.. ::0'.'.'., ••••, AHRI Certified Reference Number: 10360206 Date: 02-10-2020 Model Statuso:eft i" 6999 • • AHRI Type: RCU-A-CB : • • : • : • Series: PERFORMANCE 17 AC 2-STAGE • • • 0.0" , , • •• Outdoor Unit Brand Name: CARRIER • • • • 000000 Outdoor Unit Model Number (Condenser or Single Package) : 24ACB748A'031*' Indoor Unit Model Number (Evaporator and/or Air Handler) : FV4CN(B,F)005L Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. r The manufacturer of this CARRIER product is responsible for the rating of this system combination. r f i Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air -Conditioning. & Air -Source Heat Pump 'Equipment and subject to.rating accuracy by AHRI-sponsored, jffldependent, third party testing: Cooling Capacity (A2) Single or High Stage (95F), btuh, 48000 SEER: 16.00 EER (A2) - Single or High Stage (95F) . 13.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Retinas that are accompanied by WAS indicate an involuntary re -rate. The new published ratinq is shown along with the previous (i.e. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridlrectory.org, click on "Verify Certificate" link t,e make like better'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2020Air-Conditioning, Heating, and Refrigeration Institute