EL-20-529Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address F(3��TL'f11U Issue Date: 03/20/2020 Parcel Number 161 NE 108TH ST, Miami Shores, FL 33161 1121360090220 Contacts Permit NO.: EL-03-20-529 Permit Type: Electrical - Residential Work Classification: Generator Permit Status: Approved Expiration: 09/16/2020 JOHN & REBECCA MURRAY Owner 161 NE 108 ST, MIAMI SHORES, FL 33161 Mobile: 8122230540 ALL QUALITY ELECTRICAL SERVICES, INC Contractor SAMUEL LIGHTBOURNE 14750 S RIVER DR, MIAMI, FL 33167 Business: 3057905899 Description: NEW 22 KW NATURAL GAS GENERATOR WITH 200 Valuation: $ 3,200.00 Inspection Requests: A WHOLE TRANSFER SWITCH. TO REPLACE PERMIT#EL-19-21 305-762-4949 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $2.40 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.80 Permit Fee $62.00 Scanning Fee $9.00 Technology Fee $2.80 Total: $131.00 Payments Date Paid Amt Paid Total Fees $131.00 Credit Card 03/20/2020 $81.00 Credit Card 03/10/2020 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, Drthat ING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all'the f g information i ac rate ork will be done in compliance with all applicable laws regulating construction and zoning. Futhermor , I autf ize the abovebamee conte work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date March 20, 2020 Page 2 of 2 Zv '- RE r1'VED Miami Shores Village k,, 10i020 Building Department BY. 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC20�� BUILDING _ Master Permit No.t;✓On— � y 1D PERMIT APPLICATION Sub Permit No. ❑BUILDING ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP �� CONTRACTOR DRAWINGS JOB ADDRESS: / 1 IG, ll..' I City: Miami Shores 7 County: Miami Dade zip: 3 3 Folio/Parcel#: 11' ��1� — 00Q — 07, 1i D Is the Building Historically Designated: Yes NO Occupancy Type: �� Load: Construction Type:(-. Flood Zone: ,J BFE: FIFE: OWNER: Name•(Fee Simple Titleholder): l i r) Phone#: P.2, 2-3 -?3�� Address: / / jJ 13 City: J State: Zip: a Tenant/Lessee Na e: Phone#: Email: X� CONTRACTOR: Company Name: lia P Phone#: ,30.E 790 ndaig Address: ! City: Z 6,04 1 State: W Zip: Qualifier Name: C, - " Phone#:.fir a '/ State Certification or Registration #: Certificate of Competency #: r DESIGNER: Architect/Engineer: r G Phone#: Address: •`City." .'► State: Zip: r � Value of Work for this Permit: $ Igo. � S.quare' ine� Footage'of Work: �i . Type of Work: ❑ Addition ❑ Alteration L_VJ New ❑ Repair/Repla e i ❑ Demolition Description of Work: ck P _ e i ;Specify, color of color thru tile: Submittal Fee $ Jy ' w Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ _ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ (a oD (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur Signature -,-1,4.,-/ OWNER or AGEVI CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of MbR✓ 20 IJ by day of - 20 2�D by �J ' r Io Tv , �►'1 �• ODO� , who is personally known to �t�Nc U� t1 40<— M vA-6 is personally known to t& or who has produced 00%Wllltjui fti as me or who has produced_—L 'A UW- (.11ct ram- as identification and who did take an oath. ��``�P•;YgSION' ��� identification and who did take an oath. NOTAR PUBLIC: : vO���cy 17,2E1o•� NOTARY PU C: Sig Z�S�• IiFF99799 :O? Q` Si n: Print: �(��' ��-�U ����:�•• F ��� Print: ,'/��♦'lllllltt,1,``\\ , •`4`5''PV .. Seal: Seal: YY MY COMMISSION N GG 238273 o j EXPIRES: September 3, 2022 Bonded -M,, Notary Public tlnderwritara APPROVED BY `� 2�Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 3� e Riser Diagram, John Murray, 161 NE 108 St., MSV, FL. 33138 Notes: • All above ground conduit strapped with Unistrut • Generator line buried from house wall to generator 24" deep • Generator riser strapped with Unistrut to pad • PVC conduit from ATS to generator is 1 %" • (3) #2 wires for load and neutral • Cl) #6 Wire for ground from ATS to Generator to Ground Rod at generator • PVC conduit from ATS to generator is 1" with 7 conductor low voltage wire for signaling 22kW Generator 2" EMT Conduit w/ 2/0 wire 200 AMP Automatic Transfer Switch with Integrated Service Disconnect •• ••• • • •• 1 %" Conduit w/ #2 wire for load, buried 36" . ......... . .. ... .. . .. . 8' Ground Round, #6 Ground Wire to generator, ATS 8" High Concrete Piad .�. • ; ; ;• ;• • • ♦ • • • • • • • • • • • • • • • • • • • • • • • • • • • f • • • • • • • • • • • • • • • • • • • all Ir O 0-4 N N O Existing 2" EMT Conduit w/ 2/0 wire Generator Controlled Interior/garage House Panel 161NE1085t Residencaof•John6Vlurray Existing Panel - Interior Garage, 120/240V, Single Phase, Bus Rating = 200A, MCB = 200A # Identification MR Trip Identification # 1,3 5,7 9,11 13,15 17 19 21 23 25 27 29 31 33 35 37 39 A/C A/C Dryer Dryer Water Heater Water Heater FI Room Bed 1 Bed 2 Bath 2 Hallway Garage Door Garage Outlets Dishwasher Gen Lighting Gen Lighting 60DP 60DP 40DP 40DP 20 20 20 20 20 20 20 20 20 20 20 20 50DP 50DP 6013P 60DP 20 20 20 20 20 20 20 15 15 15 15 20 Range Range Sprinkler Sprinkler Main Lighting Main Lighting Disposal Disposal Front Bath Front Bath Kitchen Kit Fan/lite Dining Room LR/Den SE Bed Master Bed/Bath 2,4 6,8 10,12 14,16 18 20 22 24 26 28 30 32 34 36 38 40 Optional Method Format - Single Dwelling Unit Demand Line va 1978 Sq Ft. Living Area x 3VA 5934 5kw Clothes Dryer 5000 4kw Water Heater 4000 8kw Range 8000 2kw Dishwasher 2000 1/2 hp disposal. 9.8 AMP x 120 V 1176 Washer x 1500 1500 1/2 hp Sprinkler Pump 10a x 120v 1200 TOTAL OTHER LOAD va 28810 220.82 (B) Demand Factor: First 10 kva General Load @ 100% 10000 Remaining 23,810va General Load @ 40% 9524 AHU Heater 7000 A/C 5HP 28a x 240v = 6720va 6720 Total Load va 33244 33,244 va/240 = 138.52 amps *Install Load Demand Lockout Device on Range (33) amps *Install Load Demand Lockout Device on Dryer (21) amps Und-ir Gon-n-tor Total Lord va 84.62 "a load shed lockout device manufactured by Generac will be installed at range and Dryer. Both appliances will be locked out when under generator power Notes: updated w/ 2P-30 upon permit approval • . •••. ...••. • •••• • ••••• • •• •• •••• •••••• • • • •• • •••••• • Permit Type: Electrical - Residential Application Date: 01/03/2019 Owner: JOHN & REBECCA MURRAY Work Class: Generator Issue Date: 01125/2019 Parcel 1121360090220 Status: Expired Expiration Date: 08/21/2019 Address: 161 NE 108TH ST Miami Shores, FL 33161 IVR Number: 101065 Subdivision: 112136009 Scheduled Actual Reinspection Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Required? Complete 01/28/2019 01/28/2019, Electrical Rough -in INSP-003580-2019 Passed Paul Madsen No Complete Checklist Item COMMENTS Approved General Comments No 02/22/2019 02/22/2019 Electrical Final INSP-004163-2019 Re -inspection CARLOS SOSA Yes Complete required Checklist Item COMMENTS Approved General Comments No NOTES Created By TEXT Created Date Sindia Alvarez BY MR. VICKERS 02/22/2019 March 13, 2020 10050 NE 2 Ave Miami Shores FL 33138 Page 1 of 1